Duration Per Day In Hours Sound Level dBA, slow response 8 90 6 92 4 95 3 97 2 100 1 102 1 105 110 or less 115 According to OSHA, any exposure in excess of the above permissible limits could result in some hearing loss. Ear plugs or protectors in the ear canals or over the ears must be worn when operating this amplification system in order to prevent a permanent hearing loss if exposure exceeds the limits set forth above. To ensure against potentially dangerous exposure to high sound pressure levels it is recommended that all persons exposed to equipment capable of producing high sound pressure levels such as this amplification system be protected by hearing protectors while this unit is in operation.
Lightning Bolt Symbol: This symbol is used to alert the user to the presence of dangerous voltages and the possible risk of electric shock.
This symbol is used to alert the user to make special note of important operating or maintenance instructions found in the reference manual.
Laney
INTRODUCTION
Congratulations on your decision to purchase a Laney amplifier.
Laney products are designed with ease of operation as a primary objective, however to ensure you derive the best from your new amplifier, it is important you take time to read this user manual and to familiarise yourself with the control functions and facilities available.
BEFORE SWITCHING ON
After unpacking your amplifier check that it is factory fitted with a three pin 'grounded' (or earthed) plug. Before plugging into the power supply ensure you are connecting to a grounded earth outlet. If you should wish to change the factory fitted plug yourself, ensure that the wiring convention applicable to the country where the amplifier is to be used is strictly conformed to. As an example in the United Kingdom the cable colour code for connections are as follows. EARTH OR GROUND - GREEN/YELLOW NEUTRAL - BLUE LIVE - BROWN This manual has been written for easy access of information. The front and rear panels of each unit are graphically illustrated, with each control and feature numbered. For a description of the function of each control feature, simply check the number with the explanations adjacent to each panel. Your Laney RICHTER bass amplifier has undergone a thorough two stage, pre-delivery inspection, involving actual play testing, as well as burn in. When you first receive your Laney RICHTER bass amp, follow these simple procedures: (i) Ensure that the amplifier is set at the correct voltage for the country it is to be used in. (ii) Connect your instrument with a high quality shielded instrument cable. Use of cheap cables will compromise the sound of your instrument and your amplifier. Care of your Laney amplifier will prolong it's life.....and yours!.
Laney
R1 front
NORMAL HIGH
3 2 1 0 10 4 5 6 7 8 9
4 5 6 7 2 8 3 9 0 10 4 5 5 1 - 0+ 1 2 3 4 100 1K 350
2
EQUALISATION
1 2 3 4 5 5 - 0+ 1 2 2 3 3 4 4 5 5 1 - 0+ 1 2 3 4 4 5 6 7 8 9 0 10 3 2 1
COMP
3 2 1
HORN
R1
BASS AMPLIFIER 1 0
INPUTS
GAIN
ACTIVE
ON
ENHANCE
BASS
FREQUENCY
PARA-MID
LEVEL
TREBLE
ACTIVE
VOLUME
D.I.
POWER
POWER
10
11
R1 Rear
T2A L 115V WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK T1A L ~230V DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. FUSE RATING & SUPPLY VOLTAGE. CAUTION - FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH SAME TYPE AND RATED FUSE. CAUTION - TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVERS.NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. WARNING - THIS EQUIPMENT MUST BE EARTHED. ATTENTION - REMPLACER LE FUSIBLE SEULEMENT PAR LE MEME TYPE ET LE MEME CALIBRE. AVIS - RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. ATTENTION - DEBRANCHER LE CORDON DALIMENTATION MAXIMUM POWER CONSUMPTION AVANT TOUTE INTERVENTION. 120 WATTS ~50/60 HZ CAUTION
SERIAL NUMBER
12
13
14
1.Inputs: Normal and High inputs are provided for connection of bass
guitars. High output basses, either Active or Passive should be connected via the High socket. Low output basses should be connected using the normal input. High output basses may also be placed in the Normal input if pre-amp overloading is desired. pre-amp. The higher the level of gain, the more the signal will clip producing distortion. The GAIN control should be used in conjunction with the VOLUME control (10) to produce the desired signal characteristics. and disengages the on-board cpmpressor. This compresses the input-signal giving a punchier sound. In association with the compressor are two LED s,one indicating that the compressor is engaged and one indicating the compressor is active. It is possible to have the compressor engaged but it only be active during certian periods of playing - typically the most dynamic sections. Note that the higher the gain the greater the level of compression. low-end of the frequency spectrum giving you a tighter, punchier sound. The ENHANCE control does this by providing a dip in the frequency-response of the amplifier at approximately 200hz. This dip eliminates some of the secondary-harmonics of the important low-frequencies around 40-80 Hz producing a thicker sound. Turning the control through to its maximum has the effect of boosting both the low and high-frequency content of the signal whilst not effecting the mids.
2.Gain: This control is used to set the level of gain present in the
3.Compressor: Engages
Laney
6.Paramid frq: Selects
the MID-frequencies to be cut or boosted in conjunction with the PARAMID GAIN control (7). To access LO mid-frequencies turn the FREQUENCY control anticlockwise, to access HI mid frequencies turn the FREQUENCY control clockwise. by control(6). clockwise. For clockwise. For frequency-boost turn the control frequency-cut, turn the control anti-
7.Paramid Level: Sets the level of boost or cut applied to the frequency set
8.Treble: Controls the high-frequency response of the pre-amplifier. 9.Horn Switch: Switches the on-board horn either on or off. 10.Volume: Sets the overall listening level of the amplifier. 11.D.I: XLR socket for direct-injection of the amplifier signal to a
mixing-desk or additional power-amplifier. The XLR socket provides a low-impedance balanced output-signal.
12.Phones: Headphone output for silent practicing. 13.Tuner out: Socket for connecting external tuner. 14.FX Loop: Send and return sockets are provided for connecting external
effects-units.
R2 Front
NORMAL HIGH
3 2 1 0 10 4 5 6 7 8 9
4 5 6 7 2 8 3 9 0 10 4 5 5 1 - 0+ 1 2 3 4 100 1K 350
EQUALISATION
1 2 3 4 5 5 - 0+ 1 2 2 3 3 4 4 5 1
- 0+
1 2 3 3 2 4 5 1
6 7 8 9
6 7 8 9
COMP
3 2 1
LIMITER
3 2 1 0 10
HORN
R2
BASS AMPLIFIER 1 0
10
INPUTS
GAIN
ACTIVE
ON
FREQUENCY
ENHANCE
BASS
PARA-MID
LEVEL
TREBLE
PRESENCE
ACTIVE
VOLUME
ACTIVE
D.I.
POWER
POWER
R2 Rear
10
11
12
13 16
T5A L 115V WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK T2A L ~230V DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. FUSE RATING & SUPPLY VOLTAGE.CAUTION - FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH SAME TYPE AND RATED FUSE. CAUTION - TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVERS.NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. WARNING - THIS EQUIPMENT MUST BE EARTHED. ATTENTION - REMPLACER LE FUSIBLE SEULEMENT PAR LE MEME TYPE ET LE MEME CALIBRE. AVIS - RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. ATTENTION - DEBRANCHER LE CORDON Extension ALIMENTATION AVANT TOUTE INTERVENTION. Loudspeaker MAXIMUM POWER CONSUMPTION 240 WATTS ~50/60 HZ CAUTION
FXSend
FXReturn
SERIAL NUMBER
TunerOut
14
15
1.Inputs: Normal and High inputs are provided for connection of bass
guitars. High output basses, either Active or Passive should be connected via the High socket. Low output basses should be connected using the normal input. High output basses may also be placed in the Normal input if pre-amp overloading is desired.
Laney
3.Compressor: Engages
2.Gain: This control is used to set the level of gain present in the
pre-amp. The higher the level of gain, the more the signal will clip producing distortion. The GAIN control should be used in conjunction with the VOLUME control (10) to produce the desired signal characteristics. and disengages the on-board comprssor. This compresses the input-signal giving a punchier sound. In association with the compressor are two LED s,one indicating that the compressor is engaged and one indicating the compressor is active. It is possible to have the compressor engaged but it only be active during certian periods of playing - typically the most dynamic sections. low-end of the frequency spectrum giving you a tighter, punchier sound. The ENHANCE control does this by providing a dip in the frequency-response of the amplifier at approximately 200hz. This dip eliminates some of the secondary-harmonics of the important low-frequencies around 40-80 Hz producing a thicker sound. Turning the control through to its maximum has the effect of boosting both the low and high-frequency content of the signal whilst not effecting the mids.
5.Bass: Controls the low-frequency response of the pre-amplifier 6.Paramid frq: Selects
the MID-frequencies to be cut or boosted in conjunction with the PARAMID GAIN control (7). To access LO mid-frequencies turn the FREQUENCY control anticlockwise, to access HI mid frequencies turn the FREQUENCY control clockwise. control(6). For frequency-boost turn the control clockwise. For frequency-cut, turn the control anti-clockwise. the high-frequency signal-content of the preamplifier. The PRESENCE control is set at 3K. With the switch in the out position the limiter is engaged. The LIMITER is automatically triggered at high-output levels and is designed to prevent power-amp distortion at highoutput levels. When the limiter is autpmatically triggered an LED lights up to indicate the limiter is active. It is possible to have the limiter engaged but not have the LED active. The LIMITER monitors both power-amp clipping and load so it automatically registers the cabinet-impedance and sets itself accordingly.
7.Paramid Level: Sets the level of boost or cut applied to the frequency set by 8.Treble: Controls the high-frequency response of the pre-amplifier. 9.Presence: Controls
11. Volume: Sets the overall listening level of the amplifier. 12.Horn switch: Switches the on-board horn either on or off. 13.D.I: XLR socket for direct-injection of the amplifier signal to a
mixing-desk or additional power-amplifier. The XLR socket provides a low-impedance balanced output-signal.
Laney
15.Tuner out: Socket for connecting external tuner.
14.Ext Speaker This socket should be used to connect an extension-cabinet. socket: The impedance of the extension-cabinet must not be less than 8 Ohms. Connecting cabinets that have a lower impedance than 8 Ohms will result in the amplifier overheating . Continual use in this manner may cause permanent damage. Connecting a cabinet with an impedance of greater than 8 Ohms will cause no damage to the amplifier but will result in a reduced output.
16.FX Loop: Send and return sockets are provided for connecting external
effects-units..
R3/R3H Front
NORMAL HIGH
3 2 1 0 10 4 5 6 7 8 9
4 5 6 7 2 8 3 9 0 10 4 5 5 1 - 0+ 1 2 3 4 100 1K 350 2 3 4 5 5 1 - 0+
EQUALISATION
1 2 3 4 400
1K5 2 3 4 4K
- 0+
1 2 2 3 3 4 4
- 0+
1 2 3 4
6 7 8 9
COMP
3 2 1
LIMITER
3 2 1 0 10
HORN
R3
BASS AMPLIFIER 1 0
INPUTS
GAIN
ACTIVE
ON
FREQUENCY
ENHANCE
BASS
LO PARA-MID
LEVEL
FREQUENCY
HI PARA-MID
LEVEL
TREBLE
ACTIVE
VOLUME
ACTIVE
D.I.
POWER
POWER
10
11
12
13
14 17
R3 Rear
T5A L 115V WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. T2A L ~230V CAUTION - FOR CONTINUED PROTECTION RISK FUSE RATING & SUPPLY VOLTAGE.FIRE REPLACE ONLY WITH SAME TYPE ANDAGAINSTFUSE. OF RATED CAUTION - TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVERS.NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. WARNING - THIS EQUIPMENT MUST BE EARTHED. ATTENTION - REMPLACER LE FUSIBLE SEULEMENT PAR LE MEME TYPE ET LE MEME CALIBRE. AVIS - RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. ATTENTION - DEBRANCHER LE CORDON DALIMENTATION AVANT TOUTE INTERVENTION. MAXIMUM POWER CONSUMPTION CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN ! 300 WATTS ~50/60 HZ SERIAL NUMBER
FXSend
Extension Loudspeaker
8 OHM MINIMUM IMPEDANCE REFER TO USER MANUAL FOR LOUDSPEAKER CONNECTIONS
FXReturn
TunerOut
15
16
1.Inputs: Normal and High inputs are provided for connection of bass
guitars. High output basses, either Active or Passive should be connected via the High socket. Low output basses should be connected using the normal input. High output basses may also be placed in the Normal input if pre-amp overloading is desired. pre-amp. The higher the level of gain, the more the signal will clip producing distortion. The GAIN control should be used in conjunction with the VOLUME control (12) to produce the desired signal characteristics. and disengages the on-board compressor. This compresses the input-signal giving a punchier sound. In association with the compressor are two LED s, one indicating that the compressor is engaged and one indicating the compressor is active. It is possible to have the compressor engaged but it only be active during certain periods of playing - typically the most dynamic sections.
2.Gain: This control is used to set the level of gain present in the
3.Compressor: Engages
Laney
low-end of the frequency spectrum giving you a tighter, punchier sound. The ENHANCE control does this by providing a dip in the frequency-response of the amplifier at approximately 200hz. This dip eliminates some of the secondary-harmonics of the important low-frequencies around 40-80 Hz producing a thicker sound. Turning the control through to its maximum has the effect of boosting both the low and high-frequency content of the signal whilst not effecting the mids.
5.Bass: Controls the low-frequency response of the pre-amplifier 6. Lo Paramid frq: Selects the LO MID-frequencies to be cut or boosted in
conjunction with the LO PARAMID LEVEL control (7). To access low LO mid-frequencies turn the FREQUENCY control anticlockwise, to access higher LO MID frequencies turn the FREQUENCY control clockwise control (6). For frequency-boost turn the control clockwise. For frequency-cut, turn the control anticlockwise
7.Lo Paramid Level: Sets the level of boost or cut applied to the frequency set by 8. Hi Paramid frq:
Hi Paramid Frequency : Selects the HI MID-frequencies to be cut or boosted in conjunction with the Hi PARAMID LEVEL control (9). To access low Hi mid-frequencies turn the FREQUENCY control anticlockwise, to access higher Hi MID frequencies turn the FREQUENCY control clockwise Sets the level of boost or cut applied to the frequency set by control 8. For frequency-boost turn the control clockwise. For frequency-cut, turn the control anti-clockwise Controls the high-frequency response of the pre-amplifier. Allows the on-board limiter to be defeated if desired. With the switch in the out position the limiter is engaged. The limiter is automatically triggered at high-output levels and is designed to prevent power-amp distortion at highoutput levels. When the limiter is autpmatically triggered an LED lights up to indicate the limiter is active. It is possible to have the limiter engaged but not have the LED active. The LIMITER monitors both power-amp clipping and load so it automatically registers the cabinet-impedance and sets itself accordingly. Sets the overall listening level of the amplifier. Switches the on-board horn either on or off. XLR socket for direct-injection of the amplifier signal to a mixing-desk or additional power-amplifier. The XLR socket provides a balanced low-impedance output-signal.
Laney
16.Tuner out: 17.FX Loop:
15.Ext Speaker This socket(s) should be used to connect an extensionsocket: cabinet. The impedance of the extension-cabinet must not be less thean 8 Ohmsfor the R3, or for the R3H a Minimum 4 Ohms. Connecting cabinets that have a lower impedance than 8 Ohms will result in the amplifier overheating. Continual use in this manner may cause permanent damage. Connecting a cabinet with an impedance of greater than 8 Ohms will cause no damage to the amplifier but will result in a reduced output. Socket for connecting external tuner. Send and return sockets are provided for connecting external effects-units..
17
R3H Rear
T5A L 115V WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK T2A L ~230V DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. FUSE RATING & SUPPLY VOLTAGE.CAUTION - FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH SAME TYPE AND RATED FUSE. CAUTION - TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVERS.NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. WARNING - THIS EQUIPMENT MUST BE EARTHED. ATTENTION - REMPLACER LE FUSIBLE SEULEMENT PAR LE MEME TYPE ET LE MEME CALIBRE. AVIS - RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR. ATTENTION - DEBRANCHER LE CORDON DALIMENTATION AVANT TOUTE INTERVENTION. MAXIMUM POWER CONSUMPTION CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN ! 300 WATTS ~50/60 HZ SERIAL NUMBER
FXSend
Loudspeakers
FXReturn
TunerOut
15
16
R4/R4H Front
EQUALISATION NORMAL HIGH
3 2 1 0 10 4 5 6 7 8 9
4 5 6 7 2 8 3 9 0 10 4 5 5 1 - 0+ 1 2 3 4
+15 0dB
+15
2
1 3 4 5
- 0+
1 2 3 4 5
6 7 8 9
COMP
3 2 1
0dB
LIMITER
3 2 1 0 10
R4H
BASS AMPLIFIER 1 0
INPUTS
GAIN
ACTIVE
ON
-15
ENHANCE
BASS
TREBLE
ACTIVE
VOLUME
D.I.
POWER
POWER
2 11
10 13
R4/R4H Rear
FUSE RATING & SUPPLY VOLTAGE. CAUTION - REFER TO
T6.3A L 115V T3.15A L ~230V
LOUDSPEAKERS
SERIAL NUMBER
FXSend FXReturn
MAXIMUM POWER CONSUMPTION CLASS 2 WIRING MAY BE USED 450 WATTS ~50/60 HZ CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. WARNING -TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. CAUTION-FOR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH SAME TYPE AND RATED FUSE WARNING - THIS EQUIPMENT MUST BE EARTHED. ATTENTION - SE REFERER AU MANUEL DUTILISATION POUR LA CONNECTION HAUT-PARLEURS. AVIS - RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR. ATTENTION - REMPLACER LE FUSIBLE SEULEMENT PAR LE MEME TYPE ET LE MEME CALIBRE. ATTENTION - DEBRANCHER LE CORDON DALIMENTATION AVANT TOUTE INTERVENTION. ATTENTION - REFROIDI PAR VENTILATEUR. NE PAS OBSTRUER LES GRILLES DAERATION ET DE VENTILATION.
TunerOut
12
Laney
1.Inputs: Normal and High inputs are provided for connection of bass
guitars. High output basses, either Active or Passive should be connected via the High socket. Low output basses should be connected using the normal input. High output basses may also be placed in the Normal input if pre-amp overloading is desired. pre-amp. The higher the level of gain, the more the signal will clip producing distortion. The GAIN control should be used in conjunction with the VOLUME control (9) to produce the desired signal characteristics. and disengages the on-board compressor. This compresses the input-signal giving a punchier sound. In association with the compressor are two LED s, one indicating that the compressor is engaged and one indicating the compressor is active. It is possible to have the compressor engaged but it only be active during certian periods of playing - typically the most dynamic sections.
2.Gain: This control is used to set the level of gain present in the
3.Compressor: Engages
5.Bass: Controls the low-frequency response of the pre-amplifier 6.Graphic EQ: The 7-band onboard GRAPHIC-EQ allows extensive tonal-shaping
to be achieved. With the sliders along the centre-line the GRAPHIC-EQ will exert a flat signal- response it is at this point that individual frequency-bands can be cut or boosted. Moving the slider beneath the centre-line will incur a frequency-cut conversely, pushing the slider above the centre-line facilitates frequency-boost. As a general rule, avoid extreme settings of the sliders: try to set the GRAPHIC with as little cut or boost as possible. With the switch in the out position the limiter is engaged. The limiter is automatically triggered at high-output levels and is designed to prevent power-amp distortion at highoutput levels. When the limiter is autpmatically triggered an LED lights up to indicate the limiter is active. It is possible to have the limiter engaged but not have the LED active. The limiter monitors both power-amp clipping and load so it automatically registers the cabinet-impedance and sets itself accordingly.
7.Treble: Controls the high-frequency response of the pre-amplifier. 8.Limiter Switch: Allows the on-board LIMITER to be defeated if desired.
9.Volume: Sets the overall listening level of the amplifier. 10.D.I: XLR socket for direct-injection of the amplifier signal to a
mixing-desk or additional power-amplifier. The XLR socket provides a low-impedance balanced output-signal.
11.Ext Speaker This socket(s) should be used to connect an extensionsocket: cabinet. The impedance of the extension-cabinet must not be less than 8 Ohms. Connecting cabinets that have a lower impedance than 8 Ohms will result in the amplifier overheating. Continual use in this manner may cause permanent damage. Connecting a cabinet with an impedance of greater than 8 Ohms will cause no damage to the amplifier but will result in a reduced output.
12.Tuner out: Socket for connecting external tuner. 13.FX Loop: Send and return sockets are provided for connecting external
effects-units..
Laney
R5 Front
NORMAL HIGH
3 2 1 0 10 4 5 6 7 8 9
4 5 6 7 2 8 3 9 0 10 4 5 5 1 - 0+ 1 2 3 4 100 1K 350 2 3 4 5 5 1 - 0+
EQUALISATION
1 2 3 4 400
1K5 2 3 4 4K
- 0+
1 2 2 3 3 4 4
- 0+
1 2 3 4
6 7 8 9
COMP
3 2 1
LIMITER
3 2 1 0 10
HORN
R5
BASS AMPLIFIER 1 0
INPUTS
GAIN
ACTIVE
ON
FREQUENCY
ENHANCE
BASS
LO PARA-MID
LEVEL
FREQUENCY
HI PARA-MID
LEVEL
TREBLE
ACTIVE
VOLUME
ACTIVE
D.I.
POWER
POWER
5 15
10
11
12
13
14 17
R5 Rear
CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT T3.15A L ~230V REMOVE COVERS. NO USER SERVICEABLE PARTS INSIDE. FUSE RATING & SUPPLY VOLTAGE. REFER SERVICING TO QUALIFIED PERSONNEL ONLY. WARNING -TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. C -F
T6.3A L 115V
SERIAL NUMBER
AUTION OR CONTINUED PROTECTION AGAINST RISK OF FIRE REPLACE ONLY WITH SAME TYPE AND RATED FUSE WARNING - THIS EQUIPMENT MUST BE EARTHED. ATTENTION - SE REFERER AU MANUEL DUTILISATION POUR LA CONNECTION HAUT-PARLEURS. AVIS - RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR. ATTENTION - REMPLACER LE FUSIBLE SEULEMENT PAR LE MEME TYPE ET LE MEME CALIBRE. ATTENTION - DEBRANCHER LE CORDON DALIMENTATION AVANT TOUTE INTERVENTION.
EXTENSION LOUDSPEAKER
8 OHMS MINIMUM LOUDSPEAKER IMPEDANCE. CAUTION - REFER TO USERS
SPEAKER CONNECTIONS. CLASS 2 WIRING MAY BE USED MANUAL FOR RECOMMENDED
FXSend FXReturn
TunerOut
17
1.Inputs: Normal and High inputs are provided for connection of bass
guitars. High output basses, either Active or Passive should be connected via the High socket. Low output basses should be connected using the normal input. High output basses may also be placed in the Normal input if pre-amp overloading is desired. pre-amp. The higher the level of gain, the more the signal will clip producing distortion. The GAIN control should be used in conjunction with the VOLUME control (12) to produce the desired signal characteristics. and disengages the on-board compressor. This compresses the input-signal giving a punchier sound. In association with the compressor are two LED s, one indicating that the compressor is engaged and one indicating the compressor is active. It is possible to have the compressor engaged but it only be active during certian periods of playing - typically the most dynamic sections. low-end of the frequency spectrum giving you a tighter, punchier sound. The ENHANCE control does this by providing a dip in the frequency-response of the amplifier at approximately 200hz. This dip eliminates some of the secondary-harmonics of the important low-frequencies around 40-80 Hz producing a thicker sound. Turning the control through to its maximum has the effect of boosting both the low and high-frequency content of the signal whilst not effecting the mids.
2.Gain: This control is used to set the level of gain present in the
3.Compressor: Engages
Laney
10
conjunction with the LO PARAMID LEVEL control (7). To access low LO mid-frequencies turn the FREQUENCY control anticlockwise, to access higher LO MID frequencies turn the FREQUENCY control clockwise by control 6. For frequency-boost turn the control clockwise. For frequency-cut, turn the control anticlockwise Selects the HI MID-frequencies to be cut or boosted in conjunction with the Hi PARAMID LEVEL control (9). To access low Hi mid-frequencies turn the FREQUENCY control anticlockwise, to access higher Hi MID frequencies turn the FREQUENCY control clockwise by control 8. For frequency-boost turn the control clockwise. For frequency-cut, turn the control anticlockwise
7.Lo Paramid Level: Sets the level of boost or cut applied to the frequency set
9.Lo Paramid Level: Sets the level of boost or cut applied to the frequency set
10.Treble: Controls the high-frequency response of the pre-amplifier. 11.Limiter: Allows the on-board limiter to be defeated if desired.
With the switch in the out position the limiter is engaged. The limiter is automatically triggered at high-output levels and is designed to prevent power-amp distortion at highoutput levels. When the limiter is autpmatically triggered an LED lights up to indicate the limiter is active. It is possible to have the limiter engaged but not have the LED active. The LIMITER monitors both power-amp clipping and load so it automatically registers the cabinet-impedance and sets itself accordingly.
12. Volume: Sets the overall listening level of the amplifier. 13.Horn switch: Switches the on-board horn either on or off. 14.D.I: XLR socket for direct-injection of the amplifier signal to a
15.Ext Speaker This socket(s) should be used to connect an extensionsocket: cabinet. The impedance of the extension-cabinet must not be less than 8 Ohms. Connecting cabinets that have a lower impedance than 8 Ohms will result in the amplifier overheating . Continual use in this manner may cause permanent damage. Connecting a cabinet with an impedance of greater than 8 Ohms will cause no damage to the amplifier but will result in a reduced output.
16.Tuner out: Socket for connecting external tuner. 17.FX Loop: Send and return sockets are provided for connecting external
effects-units..
Laney
R1 Power Output Maximum Power Consumption 50/60Hz Input Impedance Normal/Hi Input Sensitivity Norma/Hi FX Loop Level (Nominal) Minimum Ext.Speaker Impedance Recommended Minimum Extension Speaker Power Rating 65W 120W 1M Ohm 20/40mV 700mV n/a R2 120W 240W 1M Ohm 10/20mV 800mV 8 Ohms R3 165W 300W 1M Ohm 12/24mV 800mV 8 Ohms R3H 165W 300W 1M Ohm 12/24mV 800mV R4 300W 450W 1M Ohm 12/24mV 800mV R4H 300W 450W 1M Ohm 12/24mV 800mV R5 300W 450W
11
n/a
60 Watts
80 Watts
150 Watts (4 Ohms) 150 Watts(4 Ohms) 100 watts (8 Ohms) 150 Watts(8 Ohms) n/a R115 R410 or R115 R410 R410 & R115 or R115 or 2xR410 R410 R410 & R115 or R115 or 2xR410
Laney Amplification Newlyn Road, Cradley Heath, West Midlands B64 6BE United Kingdom. WWW.laney.co.uk