Technical Information

SmartLine
SLN 700 SmartLine Non-Contact Radar
Level Specification
34-SL-03-06, October 2020

Introduction
Part of the SmartLine® family of products, the SLN 700
is a high performance 80 GHz non-contact radar level
transmitter offering high accuracy, stability over a wide
range of level applications. SmartLine SLN 700 level
transmitters are an ideal solution for demanding process
level needs, with easy-to-use and low-maintenance
character.

The SmartLine family is also fully tested and compliant


with Experion ® PKS, providing the highest level of
compatibility assurance and integration capabilities.
SmartLine easily meets the most demanding needs for
level measurement applications.

Best in Class Features:


o 80 GHz FMCW technology
Figure 1 —SLN700 Non-Contact Radar Level
o Narrow beam, small blind zone & accurate transmitter
measurement

o Immunity to temperature, pressure, most


obstacles and dust

o False echo suppression option


Description
o Easy setup, no dielectric constant dependence
The SmartLine 80 GHz Non-Contact Radar Level
o Small antenna size fits most process: easy to transmitter utilizes Frequency Modulated Continuous
install
Wave (FMCW) technology which has greater
o High resolution: better accuracy and process sensitivity and accuracy for level measuring
detail applications.
o Measuring range: up to 30 m (liquids) / 120 m
(solids)

o Accuracy ±2 mm

o Process Temperature range: -40 to 200 °C

o Process Pressure range: -1 to 25 bar

o Operating voltage: 12 to 30 V DC

o Output signal: 4 - 20 mA & HART®


2 SmartLine Level Transmitter

Unique Out-of-the-Box, Full User Experience1 Unique Indication/Display Options


The specification of the correct level transmitter for the The SmartLine SLN series level transmitter’s modular
level measurement is one of the root causes for many design accommodates a unique advanced graphics
common field failure modes. This user experience is LCD display.
enhanced with the unique SmartLine Application and
Validation Tool (AVT) found at
https://config.honeywellsmartline.com/. This allows
users to specify their tank level application and the
options desired for their level transmitter. The AVT
intelligently guides the user through the engineering
process and electronically captures and documents
the choices and inputs.

In addition to serving as engineering documentation,


the AVT output also serves as input to the Honeywell
order management system, thus ensuring correct input
of the transmitter model. The additional advantage is a
transmitter with configuration parameters already
specified to match the targeted tank application. Errors
are eliminated and the engineering effort is preserved
from start to finish.
Figure 2: Advanced Graphics LCD Display Features
The SmartLine Application and Validation Tool also
allows users to collaboratively use and share the
active session with any web connected colleague or Modular Design
expert. This interactive, collaborative capability
eliminates roadblocks and delays. Users can access To help contain maintenance and inventory costs, all
resources to help start and finish the engineering task SLN series transmitters are modular in design
in a single effort. This online tool also dynamically supporting the user’s ability to change electronic
reformats the user interface to display correctly on an modules without affecting overall performance.
IOS or AndroidTM device. Electronic modules may be swapped with another
1 will be available soon. electronics module without losing in-tolerance
performance characteristics
Diagnostics With no performance effects, Honeywell’s unique
modularity results in lower inventory needs and
SmartLine transmitters all offer digitally accessible lower overall operating costs.
diagnostics which aid in providing advanced warning of
possible failure events, minimizing unplanned Configuration Tools
shutdowns, providing lower overall operational costs
Integral Four Button Configuration Option is suitable
System Integration for all electrical and environmental requirements,
SmartLine offers the ability to configure the transmitter
o SmartLine communications protocols all meet the and display via four buttons.
most current published standards for HART®
o Integration with Honeywell’s Experion® PKS offers HandHeld Configuration
the following unique advantages. SmartLine transmitters feature two-way
• FDM Plant Area Views with Health communication and configuration capability between
summaries the operator and the transmitter. This is accomplished
• The SLN series is Experion tested to provide via Honeywell’s field-rated Multiple Communication
the highest level of compatibility assurance. Configurator.
o Display modular can be added or removed in the FDM and FDM Express
field
Honeywell’s Field Device Manager (FDM) Software
o 128 by 64 dot matrix graphics display and FDM Express are available for managing HART®
o Large PV font format supported. Echo stem plots device configurations.
with Distance to Product and Distance to
Interface Configurable screen
o The Display supports English and Chinese
languages.
SmartLine Level Transmitter 3

Product Family

SLN700L-82 (80 GHz)


for liquids in corrosive process applications
The SLN700L-82 is an 80 GHz FMCW radar
transmitter for continuous level measurement of
liquids under different process conditions. The
excellent beam focusing can provide accurate and
reliable measurement in regular or strongly corrosive
liquids.
The SLN700L-82 can measure in process
conditions with temperatures up to +200°C and
pressures up to 25 bar. The antenna options permit to
measure distances up to 30 m. It offers an extensive
choice of flanged process connections from DN50 to
DN150.

SLN700L-83 (80 GHz)


for liquids in process applications for small vessels
The SLN700L-83 is an 80 GHz FMCW radar
transmitter for continuous level measurement of
liquids under different process conditions, especially
in small vessels. The excellent beam focusing can
provide accurate and reliable measurement from
basic process to mild corrosive liquids, especially for
small vessels.
The SLN700L-83 can measure in process
conditions with temperatures up to +200°C and
pressures up to 25 bar. The antenna options permit to
measure distances up to 30 m. It offers an
extensive choice of threaded process connections
from ¾’’ to 3’’.

SLN700S-87 (80 GHz)


for solids in process applications

The SLN700S-87 is an 80 GHz FMCW radar


transmitter for continuous level measurement of solids
under different process conditions. The excellent
beam focusing can provide accurate and reliable
measurement for most powder or bulk solids
applications in storage vessels. Options for air purge
or dust shield options optimize sensor performance in
dusty conditions
The SLN700S-87 can measure in process
conditions with temperatures up to +200°C and
pressures up to 25 bar. The antenna options permit to
measure distances up to 120 m. It offers an
extensive choice of flanged process connections from
DN100 to DN150.
General Specifications

SLN700L-82 SLN700L-83 SLN700S-87

Applications: Liquids Liquids Solids


Storage vessel/process
Suitable for the strong Suitable for mildly corrosive vessel or high dust
corrosive liquids, vapours / liquids; small vessels environment
foams
Measurement range: 0~30 m 0~10 m (SLN700L-83A) 0~120 m
0~30 m (SLN700L-
83B/C/D/E)
Measurement accuracy: ±2 mm ±5mm
Process temperature (-40~150) °C (-40~130) °C (-40~130) °C
(-40~200) °C (-40~200) °C (-40~200) °C
Process pressure (-0.1~2.5) MPa (-0.1~0.3) MPa
Antenna form: SLN700L-82A/B/C/D SLN700L-83A/B/C/D/E SLN700S-87A/B/C/D
(See Antenna)

Antenna + Lens 316L+FEP 316L+PTFE 316L+PP


material: 316L+PTFE
(See Antenna) 316L+PEEK

Process Connection Flange Thread Flange


(See Antenna)
Seal Material FKM FFKM FKM
Frequency: 77-81 GHz
Signal output: 4-20 mA & HART®
Power supply: 2-wire (12~30) V DC

Housing Material: Polyester-coated aluminium


Weight SLN700L-82: approx. 5.1 to 18.4 kg
SLN700L-83: approx. 1.8 to 3.5 kg
SLN700S-87: approx. 4.8 to 8.6 kg
Ingress Protection level IP67
Unmeasurable area End of antenna

Measurement interval approx. 1 s

Adjust time approx. 3 s


Display resolution 1 mm
Display 128 × 64 pixels, with 4-button keypad
Operating Conditions – All Models
Parameter Description
Environmental Operating Device Operating range: -25 to 80°C
temperature1
Display operating range: -20 to 80°C
Temperature for storage -40 to +80 °C
and transport
Relative humidity <95%
Power Supply Standard type (12~30) V DC
2-wire Intrinsically safe (12~30) V DC
Power consumption max.22.5 mA
Ripples are allowed
-<100Hz Uss<1 V
-(100~100K)Hz Uss<10 mV
Cable parameters Cable entry/plug M20x1.5/ ½’NPT cable entry, and
M20x1.5/ ½’NPT blind plug
Spring collecting terminals Used for conductor with cross section of
2.5 mm2
Output parameter Output signal (4-20) mA/HART®
Resolution 0.3 μA
-2-wire load resistance Refer to Figure 3
1 The ambient temperature limit for intrinsic safety differs. See section on Hazardous Locaiton Approvals.

2-wire load resistance

Maximum Loop Resistance (Ω) Note: A minimum of 250 Ω of loop resistance is


required to support communications.

Loop resistance = Barrier resistance + Wire


resistance + Receiver resistance

Supply Voltage Max. Loop


(VDC) Resistance (Ω)
12 0
17.5 250
23 500
30 818

Supply Voltage(VDC)

Figure 3: 2-wire load resistance


Performance Under Rated Conditions – All Models
Parameter Description
Analog Output Two-wire, 4 to 20 mA
®
Digital Communications: HART 7 protocol
Output Failure Modes Compliance: Honeywell Standard:
Normal Limits: 3.8 – 20.8 mA
Failure Mode: ≤ 3.6 mA and ≥ 21.0 mA
Measurement accuracy Refer to figure on page 7
Temperature drift ±2 mm/10 K
Repeatability ±1 mm
Dielectric constant (minimum) 1.4
Electromagnetic Compatibility EN 301 489-1 V2.2.0, EN 301 489-3 V2.1.1, EN 302 729 V2.1.1,
and Radio Equipment EN 302 372 V2.1.1, EN 62311:2008
Electrical Safety EN 61010-1:2010
Vibration-proof Mechanical shock 10 m/s2, 10-150 Hz

Measurement accuracy under reference conditions


Measuring distance from lower edge of flange or thread

SLN700L-82A/B/C/D SLN700L-83A
Lens antenna Beam Angle Lens antenna Beam Angle
DN50 (SLN700L-82A/B) 6° ¾’’ (SLN700L-83A) 14°
DN80 (SLN700L-82C/D) 3°

SLN700L-83B/C/D/E SLN700S-87A/B/C/D
Lens antenna Beam Angle Lens antenna Beam Angle
1½’ (SLN700L-83B/C) 6° DN80 (SLN700L-87A/B/C/D) 4°
3’’ (SLN700L-83D/E) 3°
Antenna

No. SLN700L-82A SLN700L-82B SLN700L-82C SLN700L-82D


Material 316L+FEP 316L+FEP 316L+FEP 316L+FEP
316L+PTFE 316L+PTFE 316L+PTFE 316L+PTFE
Process DN50 DN80
DN50 DN80
Connection DN80 DN100
DN80 DN100
DN100 DN125
DN100 DN125
DN150 DN150
Features Anti-corrosion Anti-corrosion Anti-corrosion Anti-corrosion
High Pressure High Pressure High Pressure High Pressure
Single radiator 150 ℃ Multi-fin radiator 200 ℃ Single radiator 150℃ Multi-fin radiator 200 ℃

No. SLN700L-83A SLN700L-83B SLN700L-83C SLN700L-83D SLN700L-83E


Material 316L+PTFE 316L+PTFE 316L+PTFE 316L+PTFE 316L+PTFE

Process Thread G¾ A Thread G1½ A Thread G1½ A Thread G3 A Thread G3 A


Thread ¾ NPT Thread 1½ NPT Thread 1½ NPT
Connection
Features Anti-corrosion Anti-corrosion Anti-corrosion Anti-corrosion Anti-corrosion

No. SLN700S-87A SLN700S-87B SLN700S-87C SLN700S-87D


Material 316L+PP/ 316L+PEEK 316L+PP/ 316L+PEEK
316L+PEEK 316L+PEEK
Process DN100 DN100 DN100 DN100
Connection DN125 DN125 DN125 DN125
DN150 DN150 DN150 DN150
Features Thread/purging Thread/purging Universal/purging Universal/purging
Micro Pressure 130 ℃ Micro Pressure with Atmospheric 130 ℃ Atmospheric with
Radiator 200 ℃ Radiator 200 ℃
Housing Dimensions
AG type housing
Material: Polyester Powder Coated Aluminum

Figure 4: AG type housing

Dimensional Drawings
SLN700L-82A SLN700L-82C

Figure 5: SLN700L-82A/C
SLN700L-82B SLN700L-82D

Figure 6: SLN700L-82B/D

SLN700L-83A SLN700L-83B SLN700L-83C

Figure 7: SLN700L-83A/B/C
SLN700L-83D SLN700L-83E

Figure 8: SLN700L-83D/E

SLN700S-87A SLN700S-87B

Figure 9: SLN700S-87A/B
Hazardous Location Approvals
See manual for Special Conditions of safe use

AGENCY TYPE OF PROTECTION


IECEx Intrinsically Safe:
TUR 20.0056X Ex ia IIC T6…T2 Ga
Ex ia IIIC T85˚C...T300˚C Da
ATEX Intrinsically Safe:
TÜV 20 ATEX 8576 X II 1 G Ex ia IIC T6…T2 Ga
II 1 D Ex ia IIIC T85˚C…T300˚C Da

Ambient Temperature (˚C) Process Temperature at Temperature Class of


the Antenna (˚C) entire transmitter

-40 to +50 -40 to +50 T6/85 C


-40 to +60 -40 to +95 T5/100 C
-40 to +130 T4/135 C
-40 to +70 -40 to +195 T3/200 C
-40 to +200 T2/300 C

Intrinsic Safety Entity 4-20mA Version RS485 Version RS485 Version


Parameter Terminals 1 & 2 Terminals 1 & 2 Terminals 4 & 5

Ui 30.6V 26.4V 6.5V


Ii 131mA 166mA 68mA
Pi 1.0W 1.1W 111mW
Ci 0 0 0
Li 102uH 0 102uH
Model Selection Guide
Model Selection Guides are subject to change and are inserted into the specifications as guidance only.

Model SLN700 Series Liquid/Solid Measurement


Smartline Non Contact Radar Level Transmitter

Model Selection Guide


34-SL-16-20 Issue 1

Instructions
● Select the desired Key Number. The arrow to the right marks the selection available.
● Make one selection from each Table (I, II and IX) using the column below the proper arrow.
● A (●) denotes unrestricted availability. A letter denotes restricted availability.
● Restrictions follow Table IX.

KEY NUMBER Application Selection Availability


Liquid Level Measurement SLN700L

Solid Level Measurement SLN700S

TABLE I Antenna and Material Selections


Selection
Antenna Type Process temperature Process Pressure Lens Diameter Options Range L S
-40 to +150 °C -1…25 barg
50mm 30m 82A_ _ ●
(–40 to +302 °F) (-14.5…362 psig)
-40 to +200 deg C -1…25 barg
50mm 30m 82B_ _ ●
(-40 to +392 F) (-14.5…362 psig)
-40 to +150 °C -1…25 barg
80mm 30m 82C_ _ ●
(–40 to +302 °F) (-14.5…362 psig)
-40 to +200 deg C -1…25 barg
80mm 30m 82D_ _ ●
Flange with (-40 to +392 F) (-14.5…362 psig)
encapsulated antenna -40 to +130 deg C 0…1 barg
80mm Gimbal Flange 120m 87A_ _ ●
(-40 to +266 F) (0…14.5 psig)
-40 to +200 deg C 0…1 barg
80mm Gimbal Flange 120m 87B_ _ ●
(-40 to +392 F) (0…14.5 psig)
a. Antenna type and
-40 to +130 deg C -1…3 barg
materials 80mm 120m 87C_ _ ●
(-40 to +266 F) (-14.5…43.5 psig)
-40 to +200 deg C -1…3 barg
80mm 120m 87D_ _ ●
(-40 to +392 F) (-14.5…43.5 psig)
-40 to +130 deg C -1…25 barg
3/4'' 10m 83A_ _ ●
(-40 to +266 F) (-14.5…362 psig)
-40 to +130 deg C -1…25 barg
1½'' 30m 83B_ _ ●
(-40 to +266 F) (-14.5…362 psig)
Thread with integrated -40 to +200 deg C -1…25 barg
1½'' 30m 83C_ _ ●
horn antenna (-40 to +392 F) (-14.5…362 psig)
-40 to +130 deg C -1…25 barg
3'' 30m 83D_ _ ●
(-40 to +266 F) (-14.5…362 psig)
-40 to +200 deg C -1…25 barg
3'' 30m 83E_ _ ●
(-40 to +392 F) (-14.5…362 psig)
PTFE (-40 to +200 deg C) _ _ _0_ k
FEP (-40 to +200 deg C) _ _ _A_ a
b. Lens materials
PEEK (-40 to +200 deg C) _ _ _B_ ●
PP (-40 to +110 deg C) _ _ _C_ ●
FKM (-40 to +200 deg C) _ _ _ _0 ● ●
c. Seal materials
FFKM (-20 to +200 deg C) _ _ _ _A e

TABLE II Connection Types Material Size Rating Selection L S


Class 150lb RF AS2A c
2"
Class 300lb RF AS2B c
Class 150lb RF AS3A a ●
3"
Class 300lb RF AS3B a
Flanges Class 150lb RF AS4A d
316L 4"
ANSI Class 300lb RF AS4B d
6" Class 150lb RF AS6A f ●
6" Class 300lb RF AS6B f
8" Class 150lb RF AS8A f ●
8" Class 300lb RF AS8B f
DN50 DN50 PN40 DS5B c
Process
DN80 DN80 PN40 DS8B a
Connection
DN100 PN40 DS1B d
DN100
Flanges DN100 PN16 DS1A ●
316L
DIN DN125 PN40 DS1M f
DN125
DN125 PN16 DS1N ●
DN150 PN40 DS1Z f
DN150
DN150 PN16 DS1Y ●
3/4" NPT NS7A h
Threaded 1 - 1/2" NPT NS5A m
Fittings 316L G 3/4" GS7A h
ISO228 and ANS G 1-1/2" GS5A m
G 3" GS8A n
TABLE III Agency Approvals (see data sheet for Approval Code Details) Selection L S
No Explosion Protection Approvals Required 0 j ●
ATEX Intrinsically Safe C ● ●
Approvals
IECEx Intrinsically Safe D ● ●
NEPSI Intrinsically Safe G ● ●

TABLE IV ELECTRONICS SELECTIONS


Selection L S
a. Electronic Housing Housing Material Connection Lightning Protection
Material & Polyester Pow der Coated Aluminum 1/2 NPT None A_ _ j ●
Connection Type Polyester Pow der Coated Aluminum M20 None B__ j ●
Analog Output Digital Protocol
b. Output/ Protocol
4-20mA dc HART Protocol _H_ ● ●
Indicator Zero, Span & Config Buttons Languages
c. Customer
None None None __0 ● ●
Interface Selections
Advanced Yes EN, CH __G ● ●

TABLE V CONFIGURATION SELECTIONS


Selection L S
Diagnostics
a. Diagnostics
Standard Diagnostics 1___ ● ●
b. Advanced Interface Options
Measurement None - Standard Level _0__ ● ●
Write Protect Fail Mode High & Low Output Limits3
c. Output Limit, Disabled High> 21.0mAdc Honeywell Std (3.8 - 20.8 mAdc) _ _1 _ ● ●
Failsafe & Write Disabled Low< 3.6mAdc Honeywell Std (3.8 - 20.8 mAdc) __ 2_ ● ●
Protect Settings Enabled High> 21.0mAdc Honeywell Std (3.8 - 20.8 mAdc) __ 3_ ● ●
Enabled Low< 3.6mAdc Honeywell Std (3.8 - 20.8 mAdc) __ 4_ ● ●
d. General
Factory Standard ___ S ● ●
Configuration

TABLE VI CALIBRATION & ACCURACY SELECTIONS


Selection
Accuracy and Accuracy Calibrated Range Calibration Qty
Calibration Std Accuracy (+/-2mm) Factory Std Single Range A ● ●

TABLE VII ACCESSORY SELECTIONS Selection


No customer tag 0__ ● ●
a. Customer
One Wired Stainless Steel Tag (Up to 4 lines 26 char/line) 1__ ● ●
Tag
Two Wired Stainless Steel Tag (Up to 4 lines 26 char/line) 2__ ● ●
b. Unassembled
Conduit
No Conduit Plugs or Adapters Required _ A0 ● ●
Plugs &
Adapters

TABLE VIII OTHER Certifications & Options: (String in sequence comma delimited (XX, XX, XX,….) Selection
None 00 ● ●
Certificate of Conformance F3 ● ●
b
Calibration Test Report & Certificate of Conformance F1 ● ●
Certifications &
Extended Warranty Additional 1 year 01 ● ●
Warranty
Extended Warranty Additional 2 years 02 ● ●
b
Extended Warranty Additional 3 years 03 ● ●
Extended Warranty Additional 4 years 04 ● ●

TABLE IX Manufacturing Specials Selection


Factory Factory Identification 0000 ● ●

MODEL RESTRICTIONS
Available Only with Not Available with
Restriction Letter
Table Selection(s) Table Selection(s)
a Ia 82A, 82B, 82C, 82D, 89A, 89B
c Ia 82A, 82B
d Ia 82A, 82B, 82C, 82D
e Ia 83A, 83B, 83C, 83D,83E
f Ia 82C, 82D
h Ia 83A
j Ia 89A, 89B

k Ia 82A, 82B, 82C, 82D,83A, 83B, 83C,


83D,83E
m Ia 83B, 83C
n Ia 83D, 83E
b Select only one option from this group

®
HART is a registered trademark of HART Communication Foundation.
FOUNDATIONT M Fieldbus is a trademark of Fieldbus Foundation.
Viton® is a registered trademark of DuPont Performance Elastomers.
Teflon® is a registered trademark of DuPont.
FM Approvals SM is a service mark of FM Global

FIELD INSTALLABLE REPLACEMENT PARTS


Description Kit Number
NCR Level HART Electronics module for Liquids 50155577-501
NCR Level HART Electronics module for Solids 50155577-502
NCR Level Display module 50155578-501
Sales and Service
For application assistance, current specifications, ordering, pricing, and name of the nearest Authorized Distributor,
contact one of the offices below.

ASIA PACIFIC EMEA AMERICAS


Honeywell Process Solutions, Honeywell Process Solutions, Honeywell Process Solutions,
Phone: + 800 12026455 or Phone: + 800 12026455 or Phone: (TAC) (800) 423-9883
+44 (0) 1202645583 +44 (0) 1202645583 or (215) 641-3610
(TAC) hfs-tac- (Sales) 1-800-343-0228
support@honeywell.com
Email: (Sales) Email: (Sales)
Australia FP-Sales-Apps@Honeywell.com FP-Sales-Apps@Honeywell.com
Honeywell Limited or or
Phone: +(61) 7-3846 1255 (TAC) (TAC)
FAX: +(61) 7-3840 6481 hfs-tac-support@honeywell.com hfs-tac-support@honeywell.com
Toll Free 1300-36-39-36
Toll Free Fax: Web Web
1300-36-04-70 Knowledge Base search Knowledge Base search
engine http://bit.ly/2N5Vldi engine http://bit.ly/2N5Vldi
China – PRC - Shanghai
Honeywell China Inc.
Phone: (86-21) 5257-4568
Fax: (86-21) 6237-2826

Singapore
Honeywell Pte Ltd.
Phone: +(65) 6580 3278
Fax: +(65) 6445-3033

South Korea
Honeywell Korea Co Ltd
Phone: +(822) 799 6114
Fax: +(822) 792 9015

Specifications are subject to change without notice.

For more information


To learn more about SmartLine Transmitters,
visit www.honeywellprocess.com
Or contact your Honeywell Account Manager

Process Solutions
Honeywell
1250 W Sam Houston Pkwy S
Houston, USA, TX 77042

Honeywell Control Systems Ltd


Honeywell House, Skimped Hill Lane
Bracknell, England, RG12 1EB

Shanghai City Centre, 100 Jungi Road


Shanghai, China 20061
34-SL-03-06
October 2020
www.honeywellprocess.com 2020 Honeywell International Inc.

You might also like