AT&T LTE POWER CABLE VOLTAGE DROP TABLES


1) Load current assumed at 37.5A representing highest possible value (1500 watt RRU at lowest voltage)
2) Values based on 30 degree Celsius
3) Nominal Battery Terminal Voltage of 48 VDC
4) 40 VDC minimum voltage at the RRU power terminals (8 volt drop over trunk/jumper combination)
5) Any voltage drop reading appearing in RED requires the next size cable, jumpers or PowerShift
6) Assumes power cable is TC-ER Labeled, 90C

Please enter data for these input cells below Automated output data in t
----------------------------------------------------------------------------------------------------------------------------------------------------
Remote Radio Units (RRU) Type When choosing the specific RRU Manufacture, the RRU Powe
Consumption values will update accordingly
Ericsson Nokia Samsung
Max. Power Cable Lengths
This Calculator will only work when there is no PowerShift at the
Without PowerShift
Yes Using Y-Power Jumper Cables
With PowerShift
RRU Band Frequency
The Calculations below
B2/B25 1900 System is
(Please use the specific power
consumption figure in the chart below for
1100 RRU Power Consumption 27.5 Maximum Curren
the respective RRU)
8 Trunk Cable Type (AWG) 7.2 Trunk Voltage Drop
190 Trunk Cable Length in Feet (up to 1200 Feet) 1.2 Jumper Voltage Dro
10 Jumper Cable Type (AWG) 8.4 Total Voltage Drop
20 Jumper Cable Length in Feet (Fixed Length) Notes: A larger gauge c
Please click on Pow
NS = Not Supported

The chart below is only used when you need to know the estimated maximum
Power Cable Lengths when a PowerShift is going to be installed at the site
Ericsson RRU Information Est. Max Main Power Cable Leng
With Y-Power Jumpers
20' Jumper No PowerShift
Power Length
Band Frequency RRU Model # Specific Band Consumption (AWG) 8 AWG 6 AWG
700 RRUS-11 B12 450 10 NS NS
B12/B17
700 & 850 4449 B5/B12 1440 10 127 190
1900 RRUS-11 B2 450 10 NS NS
1900 RRUS-12 B2 650 10 NS NS
1900 RRUS-A2 B25 30 10 NS NS
1900 RRUS-32 B2 910 10 NS NS
B2/B25
1900 4415 B25 670 10 NS NS
1900 8843 B2 & B66A 1520 10 118 175
AWS-1/AWS-3 8843 B2 & B66A 1520 10 118 175
1900 Air 3246 B25 NS 10 NS NS
WCS RRUS-32 B30 800 10 NS NS
B30
WCS 4415 B30 670 10 NS NS
AWS RRUS-11 B4 450 10 NS NS
AWS-1 RRUS-12 B4 650 10 NS NS
AWS-1 RRUS-A2 B4 30 10 NS NS
B4 & B66A AWS-1 & AWS-3 RRUS-32 B66A 880 10 NS NS
AWS-1 & AWS-3 4426 B66A 809 10 NS NS
AWS-1 & AWS-3 8843 B66A 1520 10 118 175
AWS-1 & AWS-3 Air 3246 B66 NS 10 NS NS
850 RRUS-11 B5 450 10 NS NS
850 RRUS-12 B5 650 10 NS NS
B5
850 4478 B5 805 10 NS NS
700 & 850 4449 B5/B12 720 10 127 190
B29 700DE RRUS-E2 B29 670 10 NS NS
B14 Upper 700 4478 B14 650 10 NS NS
n260 39 GHz - mmWave Air 5331 n260 760 10 NS NS
NS = Not Supported

Created By: Jeff Watanabe/CommScope - 675-576-5225 jeff.watanabe@commscope.com

c/mydocuments/excel/forms/PowerShift Calculator/AT&T/
Voltage Drop Calculator

Automated output data in these cells below


----------------------------------------------------------------
acture, the RRU Power
e accordingly
PowerShift at the site.

Samsung RRU Information

he Calculations below only work if a PowerShift Power Cable Type/Length Guidelines


System is not installed
General Without PowerShift With PowerShift
Maximum Current Amps (assumes 40 volts at RRU)
RRU Size Standard 20' Standard 20'
Trunk Voltage Drop (Watts) Breaker Jumper AWG 8 AWG 6 AWG 4 AWG Jumper AWG
Jumper Voltage Drop 400 20 10 540 810 1200 10
Total Voltage Drop 650 25 10 320 480 785 10
A larger gauge cable or PowerShift is needed. 800 30 10 250 380 625 10
Please click on PowerShift Calculator Tab below to 1200 50 10 155 235 390 10
proceed
1500 50 10 120 180 295 10
estimated maximum
installed at the site
Est. Max Main Power Cable Length Est. Max Main Power Cable Length
With Y-Power Jumpers With Y-Power Jumpers
No PowerShift PowerShift
6 AWG 4 AWG 8 AWG 6 AWG 4 AWG
NS NS 725 1100 1800
190 312 500 800 1200
NS NS NS NS NS
NS NS NS NS NS
NS NS NS NS NS
NS NS NS NS NS
NS NS NS NS NS
175 290 450 720 1100
175 290 450 720 1100
NS NS NS NS NS
NS NS NS NS NS
NS NS NS NS NS
NS NS NS NS NS
NS NS NS NS NS
NS NS NS NS NS
NS NS NS NS NS
NS NS NS NS NS
175 290 450 720 1100
NS NS NS NS NS
NS NS NS NS NS
NS NS NS NS NS
NS NS NS NS NS
190 312 500 800 1200
NS NS NS NS NS
NS NS NS NS NS
NS NS NS NS NS

5### ###
8 20
###### ###
6 10
###### 4 8 1 0
###### 6 0 0
###### 400
###
V3-R2.0 - 07/08/19

delines

With PowerShift

8 AWG 6 AWG
800 875
825 850
775 825
475 650
425 575
Yes
AT&T - Pow
Radio OEM Update all fields highlighted in YELLOW
Ericsson RRU Power Type

1 # of Sites * Include Low Power RRH Low Power High Power


No Has the Raycap Squid been upgraded # of RRH/Site: 3 3
Yes Does this site require back-up Power Module? * If AT&T would like to add the correct PowerShift Module for the future,
the "Include Low Power RRH" box is checked.

PowerShift Bill of Materials


One Total PowerShift
Description
Site Sites Part Numbers
PowerShift Shelf w/Display & Controller: 1 1 PS-R-CNTRL
PowerShift 2000W Power Module (Main): 2 2 PS-1600-73
PowerShift 2000W Power Module (Back-up): 2
1 2
1 PS-1600-73
RS485-CARD
RS485 Cards:
RRH Power Y-Cable, Length 35' 3 3 DPJ10-210-35F

For a formal CommScope PowerShift Quote, please send this


spreadsheet to Jennifer Eastman ~ (779) 435-6423
jennifer.eastman@commscope.com

Created By: Jeff Watanabe/CommScope - (678) 576-5225


jeff.watanbe@commscope.com
AT&T - PowerShift
highlighted in YELLOW Main Power Back-up Power Main Power
Sub-Total Site RRU Total RRU
Module Module Module
PowerShift PowerShift
o Controller

3 3 o Display

werShift Module for the future, please make sure o RS45 Card
wer RRH" box is checked. 1st Shelf ~ PowerShift - 19" Rackmounted
o Controller
o Display
CEQ #
o RS45 Card

NEQ.20546 2nd Shelf ~ PowerShift - 19" Rackmounted


NEQ.20548
NEQ.20548
CEQ.41483

For more than 24 RRUs, please


contact CommScope

c:/mydocuments/excel/powershift/CommScopePowerShiftCalculator - V1-R2 - 0
Back-up Power
Module
o
o
o
mounted
o
o
o
mounted

wershift/CommScopePowerShiftCalculator - V1-R2 - 061218


50
50
50
50

You might also like