Product Data Sheet Rosemount 327t Temperature Transmitter en 5429156 1
Product Data Sheet Rosemount 327t Temperature Transmitter en 5429156 1
Product Data Sheet Rosemount 327t Temperature Transmitter en 5429156 1
00813-0100-4329, Rev AA
March 2019
The Rosemount 327T Temperature Transmitter, featuring Drift Monitoring Diagnostics and sensor backup technology,
provides layers of safety to ensure your food and beverage operations are in specification.
March 2019
Emerson offers a full service organization to give you the support you need
From simple repairs to complex projects, Emerson supports you with training and instrument services that improve the
maintenance, reliability and performance of your products and, ultimately, your process equipment and production quality. We
have a full organization of experienced and certified personnel. With both factory and regional service centers, we offer unmatched
local support around the world.
Contents
Emerson is here to optimize your food and beverage operations....................................................................................................... 2
Ordering information........................................................................................................................................................................ 3
Performance specifications................................................................................................................................................................5
Functional specifications................................................................................................................................................................... 5
Physical specifications....................................................................................................................................................................... 8
Product certifications...................................................................................................................................................................... 10
Dimensional drawing.......................................................................................................................................................................11
2
March 2019
Ordering information
Table 1: 327T Temperature Transmitter ordering information
The Standard offering represents the most common options. The starred options (★) should be selected for best delivery. The
Expanded offering is subject to additional delivery lead time.
Model
327T Temperature transmitter ★
Immersion length
L033 1.3 inches (33mm) ★
L050 1.97 inches (50mm) ★
L087 3.44 inches (87.5mm) ★
Process connection
G10 G1" thread ★
Housing material
A Stainless steel ★
Calibration certification
Q4 Calibration certificate
Material traceability certification
Q8 Material Traceability per EN 10204 3.1B
Note
Optional options will not be included in the model string printed on the transmitter. For product reorder, make sure to include any
desired optional options in the model string.
3
March 2019
Note
For a material traceability certificate, add option code Q8 after your part number (Ex: FB-1001Q8). Additional delivery lead times
may apply. The certification option (Q8) will not be included in the part number printed on the transmitter. For product reorder,
make sure to include any desired certification in the part number.
O-rings
Description Part number
Hygienic Adapter O-ring; FKM, Qty 1 FB-3001
Hygienic Adapter O-ring; FKM; Qty 5 FB-3002
Hygienic Adapter O-ring; EPDM; Qty 5 FB-3003
Hygienic Adapter Upper Gasket; PEEK; Qty 1 FB-3010
4
March 2019
Performance specifications
Transmitter accuracy
Temperature range Deviation
14 to 266 °F (-10 to 130 °C) ±0.36 °F (0.2 °C)
266 to 284 °F (130 to 140 °C) ±0.54 °F (0.3 °C)
284 to 320 °F (140 to 160 °C) ±0.54 °F ± (0.1% span)
-13 to 14 °F (-25 to -10 °C) ±0.54 °F ± (0.1% span)
Dynamic performance
T05: 3 seconds
T09: 6 seconds
Vibration
The Rosemount 327T is tested to DIN EN 60068-2-6 and has a peak acceleration of 20 g in the frequency range 10 to 2000 Hz.
Functional specifications
Service
Liquid and gas applications
5
March 2019
Measuring range
-25 to 320°F (-25 to 160°C)
Maximum continuous temperature is 302°F (150°C). Maximum operation time above this temperature depends on process
temperature:
Figure 1: Maximum Operating Time by Process Temperature
Factory settings
4 mA: 0°F
20 mA: 300 °F
Temperature limits
Ambient
-13 to 158 °F (-25 to 70 °C)
Storage
-40 to 185 °F (-40 to 85 °C)
Vacuum resistance
-14.5 psi (-1 bar)
Power supply
18 – 32 V DC (For cULus a Class 2 source required)
6
March 2019
Current draw
< 6 mA (at 24V)
Load limitation
(Power Supply Voltage – 15) x 50 Ω
Protection class
III
Output
In a two-wire configuration, the Rosemount 327T provides a 4-20 mA analog output. In a three-wire configuration, digital IO-Link
communication or Drift Monitoring Diagnostics can also be utilized for increased transmitter functionality
OUT2: 4-20 mA (analog)
OUT1: IO-Link (digital) / Drift Monitoring Diagnostics
For more information on how to acess these outputs see Electrical connection.
Switch output
Max voltage drop: 2.0 V
See the below table for current ratings of the switching output by temperature.
IO-Link
Table 2:
7
March 2019
Table 2: (continued)
Diagnostics
Drift monitoring diagnostic
The temperature transmitter uses two different, thermally coupled sensor elements (NTC, PT 1000) to automatically detect drifts
and errors in the temperature measurement. The temperature transmitter forms an average value using the individual NTC and PT
1000 measured values. It then calculates the deviation of each sensing element to the average. The permissible temperature
deviation is configurable and the transmitter will send alerts/alarms when it is outside the set specification. Different diagnostic
states can be communicated by the transmitter via either the analog signal or a separate configurable switch output.
Sensor backup
If one of the two internal sensor elements fails, the temperature transmitter will continue to communicate the temperature
reading of the remaining sensor to prevent loss of measurement. The transmitter can also send an alert that it is in sensor backup
mode using the switch output on pin 4 (OUT1).
Note
For more information on diagnostic configuration, please see the Rosemount 327T Temperature Transmitter Quick Start Guide
(00825-0100-4329).
Turn-on time
8 seconds
Physical specifications
Material selection
Emerson provides a variety of Rosemount products with various product options and configurations including materials of
construction that can be expected to perform well in a wide range of applications. The Rosemount product information presented
is intended as a guide for the purchaser to make an appropriate selection for the application. It is the purchaser’s sole responsibility
to make a careful analysis of all process parameters (such as all chemical components, temperature, pressure, flow rate, abrasives,
contaminants, etc.), when specifying product, materials, options and components for the particular application. Emerson is not in a
position to evaluate or guarantee the compatibility of the process fluid or other process parameters with the product, options,
configuration or materials of construction selected.
Measuring elements
The Rosemount 327T Temperature Transmitter has two sensing elements, an RTD (PT1000) and a thermistor (NTC).
8
March 2019
Process connections
External threaded G1” connection
Non-wetted parts
■ 316L SST
■ PEI
■ FKM
Electrical connection
The Rosemount 327T is equipped with an M12 Female electrical connector which features gold-plated contacts.
Use either a two-wire or three-wire configuration to access the desired number of outputs.
Figure 2: Two-wire Configuration
9
March 2019
Shipping weights
Table 3:
Product certifications
European directive information
The most recent revision of the EC Declaration of Conformity can be found at Emerson.com/Rosemount.
®
3-A certification
This product is authorized to display the 3-A symbol. Ensure gaskets and process connection accessories selected for installation
meet both the application and 3-A requirements. A certificate of compliance is available at Emerson.com/Rosemount.
10
March 2019
Dimensional drawing
Immersion Length Option Length A
Code
L033 1.30in. (33 mm)
L050 1.97in. (50 mm)
L087 3.45in. (87.5 mm)
11
00813-0100-4329
Rev. AA
March 2019
Asia Pacific Regional Office Middle East and Africa Regional Office
Emerson Automation Solutions Emerson Automation Solutions
1 Pandan Crescent Emerson FZE P.O. Box 17033
Singapore 128461 Jebel Ali Free Zone - South 2
+65 6777 8211 Dubai, United Arab Emirates
+65 6777 0947 +971 4 8118100
Enquiries@AP.Emerson.com +971 4 8865465
RFQ.RMTMEA@Emerson.com
Linkedin.com/company/Emerson-Automation-Solutions
Twitter.com/Rosemount_News
©2019 Emerson. All rights reserved.
Facebook.com/Rosemount
Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a
Youtube.com/user/RosemountMeasurement
trademark and service mark of Emerson Electric Co. Rosemount is mark of one of the
Google.com/+RosemountMeasurement Emerson family of companies. All other marks are the property of their respective owners.