UNINTERRUPTIBLE POWER SUPPLY

UPS
ARCHIMOD UPS
MODULAR
THREE-PHASE
from 20 to 120kVA

THE GLOBAL SPECIALIST


IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES
ARCHIMOD
modular
Efficiency up three-phase
to 95% when in
ON LINE MODE

Standard modules
with self-configurable
Plug&Play system

Power factor close


to 1 at input

Multi IN/OUT to obtain


different three-phase
or single-phase
configurations ON SITE

ARCHIMOD is the UPS with a modular


and expandable architecture with power
from 20 to 120kVA, in 19 inch rack cabinet.

The system is made from a set of


standard and pre-assembled components
that allow simplifying and speeding up
the design and completion process
for infrastructures.
®

MODULAR
ARCHITECTURE
6

1 Control logics
Equipped with microprocessor, it manages
3 power modules.If combined with a power
expansion module, it can manage up to 6 power
modules, thus increasing power from 20 to 40kVA.
It comes equipped with a multifunction 1
display and keyboard to monitor UPS
operating parameters, and to configure
numerous functions.
It can be connected in parallel to other control
modules and with power modules.
On the front side, there is a backlit status
indicator to immediately identify the system’s
operation status, and an RS232 communication
port for maintenance.

2 Power modules 2
Power modules, with power equal to 6.7 kVA,
are extremely compact and easy to move.
Equipped with a plug-in and real hot-swap
system, installation and maintenance is quick.
They work in parallel with all modules to
guarantee maximum system performance.
3
3 Power expansion module
It must be combined with a control module.
Power can be increased from 20 to 40 kVA,
and redundancy on single-phase can be set. 4

4 Battery module
Each module has batteries that can be connected
to others in series, creating independent strings.
The compactness and functionality of individual
modules (plug-in) means they can be easily
moved and expanded without changing the
installed solution (flexibility and scalability).

5 Distribution
UPS can be configured directly on site into
different distribution systems (three-three,
three-single, single-single and single-three).
Inside there are terminal blocks
for in-out connection, movement and
protection components, and the predisposition
for additional battery cabinets.
Power supply can be configured on two separate
input networks (primary and emergency by-pass).

6 Input cable
Input cable compartments allow inserting in-out
connection cables at both the top and bottom. 5

WWW.UPS.LEGRAND.COM
ARCHIMOD
Modular three-phase UPS with double conversion VFI

Configurations

20 40
Power: 20 kVA Power: 40 kVA
Uptime (80% of the load): 1h Autonomy (80% of the load): 20 min
1 Cabinet 1 Cabinet
1 Control module 2 Control modules
3 Power modules 6 Power modules
30 Battery modules 24 Battery modules
1 Distribution modules 1 Distribution modules

3 108 55

3 104 54 3 108 40
60 80
Power: 60 kVA Power: 80 kVA
Pack. Item Configurable cabinets Uptime (80% of the load): 6 min Autonomy (80% of the load): 12 min
1 Cabinet 2 Cabinets
The cabinets are supplied empty and are pre-set for power and 3 Control modules 3 Control modules
uptime as indicated in the table 9 Power modules 1 Power expansion module
Nominal No. battery No. modules No. modules No. phases 18 Battery modules 12 Power modules
power kVA modules for control for power 1 Distribution modules 36 Battery modules
expansion 1 Distribution modules
3 104 51 * 20 12 1 - 3-1/3-3
3 104 52 20 30 1 - 3-1/3-3
3 104 53 40 24 2 - 3-3/3-3
3 104 54 60 18 3 - 3-3
3 104 55 80 - 3 1 3-3
3 104 56 100 - 3 2 3-3
3 104 57 120 - 3 3 3-3
* cabinet with 18 rack units available

Additional cabinets for batteries


Description

3 108 18 Empty modular battery cabinet


3 108 21 Battery cabinet for 20kVA UPS
with 21 94 Ah long life batteries
3 108 22 Battery cabinet for 40-60kVA UPS
with 21 94 Ah long life batteries 100 120
3 108 23 Battery cabinet for 80kVA UPS Power: 100 kVA Power: 120 kVA
with 21 94 Ah long life batteries Autonomy (80% of the load): 10 min Autonomy (80% of the load): 6 min
2 Cabinets 2 Cabinets
3 108 24 Battery cabinet for 100-120kVA UPS 3 Control modules 3 Control modules
with 21 94 Ah long life batteries 2 Power expansion modules 3 Power expansion modules
3 108 65 Cover for closing empty battery slots 15 Power modules 18 Power modules
3 108 66 Cover for closing empty power module slots 36 Battery modules 36 Battery modules
1 Distribution modules 1 Distribution modules

Accessories
Description

3 108 40 6.7kVA power module


3 108 64 Front/rear closing door
3 108 55 Kit of 3x9Ah battery slots
3 108 56 Kit of 3 empty battery slots

NOTE: autonomy values, expressed in minutes, are measured during optimal


operating conditions.
ARCHIMOD
Modular three-phase UPS with double conversion VFI

3 104 51
Idem 3 104 53 3 104 54 3 104 55 3 104 56 3 104 57
3 104 52
General features
Nominal Power (kVA) 20 40 60 80 100 120
Active power (kW) 18 36 54 72 90 108
Module Power (kVA) 6.7 for the Power Module (20kVA with 3 Modules), power factor 0.9
Technology On-Line Double Conversion VFI-SS-111
System Modular, expandable and redundant UPS system in just one 19’’ rack cabinet
Hot Swap capacity Possibility of replacing the power modules and/or battery without turning off the UPS
Input features
Input voltage 230V 1F+N, 400V 3F+N 400V 3F+N
Input frequency 50-60 Hz ±2% Autosensing
230V +15%/-20% 1F
Input Voltage Range 400V +15%/-20% 3F
400V +15%/-20% 3F
THD Input Current ‹ 3%
Configurable in order to achieve synchronism between input
Compatibility with Power-Supply Units
and output frequencies, even for wider frequency ranges, ±14%
Input Power Factor › 0,99
Output features
Output voltage 230V 1F, 400V 3F 400V 3F
Performance at Full Load 95%
Nominal output frequency 50/60 Hz ±0.1
Crest Factor 3,5:1
Output Voltage Tolerance ±1%
Allowed Overload 10 minutes at 125% and 1 minute at 150%
Performance in Eco Mode 99%
Bypass Automatic and maintenance bypass
Batteries
The battery modules are designed to easily be fitted inside the cabinet.
Battery Module
No particular operation is necessary to connect them
Battery Series Type/Voltage VRLA - AGM / 252 Vdc
Uptime Configurable and expandable both internally and with additional battery cabinets
Battery Charge Smart Charge technology. 3-stage advanced cycle
Configuration and management
4 lines/20 characteristics, 4 buttons for menu navigation,
Display and Signals
multi-colour LED status indicator
2 RS232 serial ports, 1 Logical gate, 5 ports with dry contacts,
Communication Ports
2 slots for SNMP interfaces (optional)
Emergency Power Off (EPO) Yes
Remote Management Available
Physical features
Dimensions (H x W x D) (mm) 2080 x 570 x 912 (42U)
Installed Power Modules 3 6 9 12 15 18
Installable Battery Slots Up to 30 Up to 24 Up to 18 - - -
Net Weight (kg) 205 240 276 272 318 364
Environmental conditions
Operating Temperature/Humidity 0 - 40 °C / 20 - 80% non-condensing
Degree of protection IP21
Maximum Audible Noise at 1 m from the Unit (dBA) 50÷65
Heat Loss (BTU/h) 2730 5460 8190 10920 13650 16380
Conformity
Certifications EN 62040-1, EN 62040-2, EN 62040-3
Standard Warranty 2-year warranty
Services
Can be performed by the user, modular architecture with "plug and play"
Installation
power and battery modules for easy installation and configuration
Maintenance Can be performed by the user, optional services available from the manufacturer