Nothing Special   »   [go: up one dir, main page]

Siemens SGT600 Data

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

SGT-600

Industrial gas turbine

High reliability and availability in combination with good The industrial gas turbine combines a robust, reliable
fuel flexibility and third-generation DLE makes the SGT-600 design with high fuel flexibility and low emissions.
a perfect choice for several onshore applications:
Industrial power generation, oil and gas power generation, More than 350 units have been sold with over 10 million
and mechanical drive applications. Within the IPG applications, operating hours. The fleet-leading gas turbine has 190,000
the turbine performs well in combined heat and power operating hours.
plants and combined cycle plants.

References

Bahia Blanca, Argentina


Combined heat and power
Customer: Profertil S.A.
Scope: 1 × SGT-600 gas turbine,
STC-GV (80-6) compressor, generator,
NEM heat recovery steam generator

Tiszaújváros, Hungary
Combined cycle power plant
Customer: TVK Ltd
Scope: 1 × SGT-600 gas turbine and
1 × SST-700 steam turbine

SGT-600 installation for both mechanical drive and power generation

1.
Power generation: 24.5 MW(e)
Mechanical drive: 25.2 MW
„ Robust, reliable design
„ High fuel flexibility
„ Low emissions

Maintainable, reliable, and robust twin-shaft design for mechanical drive and For both power generation and mechanical drive package,
power generation the driver is the same

Simple cycle power generation Mechanical drive applications

Power output 24.5 MW(e) 25.2 MW

Fuel Natural gas, liquid fuel, dual fuel Natural gas, liquid fuel, dual fuel

Frequency 50/60 Hz

Gross efficiency 33.6% 34.6%

Heat rate 10,720 kJ/kWh 10,390 kJ/kWh

Turbine speed 7,700 rpm 3,850 – 7,700 – 8,085 rpm*

Pressure ratio 14.0 : 1 14.0 : 1

Exhaust mass flow 81.3 kg/s 81.3 kg/s Note: All combined cycle is based on 2 pressure, no reheat.
Dimensions exclude inlet filter housing and exhaust stack. For power
Exhaust temperature 543 °C (1,009 °F) 543 °C (1,009 °F) generation, AC generator is included. For mechanical drive, driven
equipment is excluded.
NOX emissions ≤ 9 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 9 ppmvd at 15% O2 on fuel gas (with DLE)
* Value shown indicates 100%-design speed of drive shaft

Combined cycle power generation Physical dimensions

Siemens combined SCC-600 1 × 1 SCC-600 2 × 1 Power generation package Mechanical drive package
cycle power plant
Approx.
Net power output 35.9 MW(e) 73.3 MW(e) weight 149,688 kg (330,000 lb) 58,968 kg (130,000 lb)

Net plant efficiency 49.9% 50.9% Length 18.8 m (61.68 ft) 11.7 m (38.38 ft)

Net heat rate 7,220 kJ/kWh 7,071 kJ/kWh Width 4.6 m (15.09 ft) 4.0 m (13.12 ft) http://www.soarpower.com
Number of gas turbines 1 2 Height 4.0 m (13.12 ft) 4.0 m (13.12 ft) E-mail:sale@soarpower.com

2.

You might also like