Nothing Special   »   [go: up one dir, main page]

Pierlite ECO LED Batten Gen 3 Installation Guide 2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

96-112 Gow Street, Padstow, NSW 2211

T: 02 9794 9300 | www.glg.lighting

INSTALLATION / WARRANTY INSTRUCTIONS issue date: 30/09/2019

PRODUCT BRAND Pierlite ECO LED Batten Gen 3

PRODUCT NAME / CODES ECOBAT202ECSG3, ECOBAT404ECSLS

PLEASE READ THESE INSTALLATION INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR MAINTAINING THIS
EQUIPMENT. THE PRODUCT IS DESIGNED FOR INSTALLATION AND MAINTENANCE IN ACCORDANCE WITH
RELEVANT AUSTRALIAN STANDARDS (AS3000) AND LOCAL REGULATIONS (WHERE APPLICABLE), BY AN
AUTHORISED AND LICENCED ELECTRICIAN. THE INSTALLATION INSTRUCTIONS WERE CORRECT AT THE TIME OF PRINT.
TO REFLECT CHANGES IN TECHNOLOGY AND AUSTRALIAN STANDARDS; GERARD LIGHTING RESERVES THE RIGHT TO AMEND
THE INSTRUCTIONS WITHOUT NOTICE. UPDATED GUIDELINES CAN BE FOUND ON THE RELEVANT BRAND WEB SITE.
IMPORTANT - THE PRODUCT MUST BE MAINTAINED AND OPERATED IN ACCORDANCE WITH THE MANUFACTURER’S
INSTRUCTIONS, FAILURE TO DO SO MAY DAMAGE THE PRODUCT AND SERVICES. IT IS STRONGLY RECOMMENDED THAT THIS
IMPORTANT NOTE BE COMMUNICATED TO THE OWNER AND OR OPERATOR OF THE INSTALLATION AT THE TIME OF SITE
COMMISSIONING. GOOD PRACTICE DOES NOT RECOMMEND THE 24/7 USE OF PRODUCTS WITHOUT THE APPLICATION OF
SUITABLE SWITCH CYCLE INTERVALS. FURTHERMORE, WITH THE OMISSION OF NOMINATED SURVIVAL CURVES AND OR
RECOMMENDED OPERATING HOURS, PRODUCT DESIGN EXPECTATIONS PROVIDE FOR A CONTINUAL DAILY USAGE OF 6 HOURS
FOR RESIDENTIAL APPLICATIONS AND A CONTINUAL DAILY USAGE OF 12 HOURS FOR COMMERCIAL AND INDUSTRIAL
APPLICATIONS. ALL PRODUCTS MUST BE THOROUGHLY CLEANED ON A REGULAR BASIS AT INTERVALS THAT REFLECT IN THE
INSTALLATION ENVIRONMENT, ENSURING THE OPTICAL PERFORMANCE, TOGETHER WITH THE ELECTRICAL, MECHANICAL AND
STRUCTURAL INTEGRITY AS DESIGNED, IS MAINTAINED THROUGHOUT THE SERVICE LIFE OF THE PRODUCT.

1. PRODUCT SPECIFICATION :
ECOBAT202ECSG3 ECOBAT404ECSLS
Type of Protection Class I
Body Material Steel body with Opal Polycarbonate diffuser
Finish Powder coated
Circuit Wattage 18W 36W 30W 25W 18W
Nominal Voltage 220-240V
Line Current 0.07A 0.15A 0.14A 0.12A 0.09A
Nominal Freq. (Hz) 50Hz
Power factor >0.90
Inrush current <12A/350us <20A/350us
Leakage current 0.75mA 0.35mA
Rated operating ambient
temperature 40 degree Celsius
LED lifetime (L80 B50) @ 25 °C 54,000 hours
4000K (1700lm), 5000K (1900lm),
Lumen output (lm) 6500K (1700lm) please refer to next page
IP Rating IP20 for interior use only
Suitable for direct mounting on
flammable surfaces No
Dimmable No
Installation orientation Surface mounted
Installation type Fixed
Designed application Interior commercial (Interior)
Electrical connection hard wired
Dimensions 74mm x 74 mm x 603mm 74mm x 74mm x 1164mm
Net Weight of luminaire 0.8 kg 1.51 kg
96-112 Gow Street, Padstow, NSW 2211
T: 02 9794 9300 | www.glg.lighting

ECOBAT404ECSLS is a colour select and power select batten. Factory settings could be altered accordingly by
adjusting the DIP switches on the driver.

Power select dip switches are located on the driver

System
Colour Wattage
select Line
dip switches areCurrent Driver
located on the settings
LED module 4000K (lm) 5000K (lm) 6500K (lm)
(W) (A) (mA)

36W 0.15 350 3600 4100 3700

30W 0.14 300 3200 3600 3300

25W 0.12 250 2700 2960 2770

18W 0.09 200 2180 2300 2190

1. APPROVALS: The RCM marking of this product applies to AS/NZS CISPR15 (EMC) “Limits and methods of
measurement of radio disturbance characteristics of electrical lighting and similar equipment”. This product is
designed to conform to AS/NZS60598 “Luminaires, general requirements and tests”.

2. STORAGE: Prior to installation products are to be stored in cool and dry conditions.

3. APPLICATION: The installation application and orientation of the product is designed in accordance with the nominated
product IP rating, class designation and these installation instructions. Installation environments and operating conditions
beyond these instructions are not recommended.

4. INSTALLATION / GENERAL: Installation of the product is to be completed by an authorized and licensed electrician,
in accordance with these instructions, relevant Australia standards and local regulations (where applicable). Termination of
product wiring, together with the installation of the product must be in a manner and orientation that maintains the integrity of
the designated IP rating of the product For electronic control equipment (when supplied) DO NOT MEGGER between A and N.

5. INSTALLATION / SPECIAL CONDITIONS (relevant only for products approved for such an installation):

(a) products installed in high wind environments must have suitable installation / fastening methods applied to
ensure the product’s mounting points are not damaged through, corrosion, constant vibration and or movement. Exterior
products are designed with precise vertical aiming limits, which should not be exceeded. Any vertical floodlight aiming
requirements should be specifically validated in writing with the relevant brand before consideration.
(b) products installed in corrosive or salt laden environments require special consideration and such; specific
product selection, inclusive of suitable fastening methods and extensive ongoing maintenance of products installed in these
environments require professional advice. It is essential that all aspects of the product selection, material specification and
maintenance are specifically designed for such use and a cleaning program be adopted that maintains the design integrity of the
product. (c) interior highbay products must be vertically suspended. The method of suspension (chain etc) must be able to
support at least 5 times the total weight of the fitting. Do not install where air movement will cause the fitting to swing about,
96-112 Gow Street, Padstow, NSW 2211
T: 02 9794 9300 | www.glg.lighting
causing wear and tear of attachment points. Luminaires should be installed where access for maintenance is practical and allows
for maintenance to be completed in accordance with the manufacturer’s recommendations.
(d) interior (downlight) products must be installed to ensure the lamp unit or the driver (if supplied) are not covered with
any combustible materials or insulation; minimum spacings nominated for these materials are mandatory. Unless otherwise
specified, minimum clearances are in accordance with AS3000 requirements. The product is not designed for installation
environments which restrict conventional airflow movements eg: enclosed boxes or concrete profiles. For dimming purposes
please see the relevant product brand web site for the dimming compatibility chart. When mounting multiple fixtures to
conductive structures, it is recommended that the structure is earthed. The mounting facilities provided for the
transformer/driver (if any), need only be utilized if in the application of the product is required by AS3000. IP ratings stated (if
any) are from below the ceiling unless stated otherwise and the installation of the product must be in a manner that maintains
the integrity of the relevant IP rating.

7. MAINTENANCE:
(a) The supply must be isolated before opening or accessing the luminaire. Product maintenance is IMPORTANT and is critical to
the products designed performance. The product is to be maintained in accordance with the manufacturer’s instructions. For the
latest product maintenance guides please go to relevant brand web site. Gerard Lighting is not responsible for any product not
maintained in accordance with the recommended procedure or intervals. (b) lamps (where provided): The product is
designed with the supplied (LEDs) / LAMP/s and it is strongly recommended that any LAMP / (LEDs) changes (if any) be made in
accordance with the type, colour and brand supplied. For recommended LAMP / LED maintenance or operating guides (inclusive
of recommended product switch cycles and mandatory run-in procedures for HID and Fluorescent lamps when used with
dimming circuits), Gerard Lighting recommends the application of the lamp manufacturer’s operating guidelines, which can be
found on manufacturer’s website. Gerard Lighting is not responsible for the product performance of alternative lamp/s used. As a
member of FluroCycle, we encourage recycling of lamps and components. (c) battery (where provided): The battery is
designed with a rated average battery design life of 25,000 hours in standby mode. The battery is supported with a standard 12-
month warranty; conditional of the product being maintained and operated in accordance with the manufacturer’s guidelines and
tested in accordance with AS/NZS2293. For guidelines see product installation instructions or visit the relevant brand web site.
(d) for products supplied with glass visors or covers, do not operate the product with a damaged visor or cover; it is
recommended the product be turned off, area surrounding the product vacated and the damaged glass replaced by a
professional installer immediately.

8. WARRANTY INSTRUCTIONS: For the purpose of warranty claims (if any) the following instructions apply:
Warranty components – THE PRODUCT, (identified as the THE PRODUCT only). Warranty period - The above components
are provided with a warranty of FOUR (4) years or 20,000 hours against manufacturing defects or failure to perform to
specifications for products installed by an authorised installer in accordance with the manufacturer’s installation instructions and
which have not been subject to incorrect operation or maintenance, unauthorised modification or damage arising from any
intervening cause. Warranty reference - The warranty reference date commences from the date of purchase. Warranty point
of contact – Gerard Lighting Pty Ltd, 96 Gow Street Padstow NSW 2211, phone T 02 9794 9300 contact – Gerard Lighting After
Sales Support.

Warranty claim procedure – For the purpose of making a claim the customer must:
1. Contact the “point of contact” above and upon provision of proof of purchase the customer will receive a goods return advice
(GRA) number. 2. At the customer’s expense, collect and return the goods to the “point of contact” with the issued GRA number.
3. Upon receipt of the goods, Gerard Lighting will review the claim and if found to be accepted, Gerard Lighting will return a
replacement product to the customer to install at the customer’s expense. Alternatively, if the claim is rejected, the customer
may request the return of the goods at their expense. Consumer Contracts - The benefits to the customer given by the Gerard
Lighting warranty are in addition to other rights and remedies of the customer if the goods are the subject of a Consumer
Contract under the Australian Consumer Law. In that event the following statement is required to be brought to the Consumer’s
attention:- Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a
replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are
also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount
to a major failure. Limitation of Liability – if the goods are not purchased by the customer under a Consumer Contract within
the Australian Consumer Law then but not otherwise;- (a) the Company is not liable in tort for any loss or damage suffered by
the customer or by any third party; and (b) in no circumstances is Gerard Lighting liable to the customer or to any third party
for any loss of profits, loss of anticipated savings, economic loss or interruption of business or for any indirect or consequential
loss (Consequential Loss). Terms of Sale – these Warranty provisions are in substitution for any inconsistent provisions in the
Gerard Lighting Terms and Conditions of Sale in so far as they apply to the Warranty components.
96-112 Gow Street, Padstow, NSW 2211
T: 02 9794 9300 | www.glg.lighting
Line Drawings

ECOBAT202ECSG3

ECOBAT404ECSLS
96-112 Gow Street, Padstow, NSW 2211
T: 02 9794 9300 | www.glg.lighting
antenna module

36.5
sensitivity

4.1
hold-time
daylight threshold
65
71.5
80.4

23.5
daylight sensor installation hole
11.9

L’ N N L

Sensor The motion detector can turn on the light based on movement. With this detector built in, light is
On/off function
Feature automatically on when needed and off when not.

The light keeps off during daytime even when With movement and insufficient ambient lux If there is no more movement, the light turns off
movement is detected. (Ambient lux level is level, the light is triggered on by the detector. automatically after hold-time preset.
above preset daylight threshold)
Sensor Wiring N
L

L N
L N N L’
control gear

Detection pattern Ceiling mounting (m) Wall mounting (m)


5 4 3 2 1 1 2 3 4 5 1 2 3 4 5 6 7 8 9

4
1

3
2

2
height (m)

height (m)
1
3

1
5
2
6
3
4

high sensitivity area low sensitivity area high sensitivity area low sensitivity area

Settings
1 2
1. Sensitivity I – 100%
100%
II – 75%
Sensitivity can be adjusted by selecting the combination 75%
III – 50%
on the DIP switches for different applications. 50%
IV – 10%
10%

2. Hold-time 3 4
I – 5s
5s
II – 90s
Hold-time refers to the time period that the light remains 90s
III – 5min
100% on if no more movement is detected. 5min
IV – 15min
15min

5 6
3. Daylight sensor I – Disable
Disable
II – 50Lux
Different daylight threshold can be preset on DIP switches. 50Lux
III – 10Lux
Light will always turn on upon movement if daylight sensor 10Lux
IV – 2Lux
is disabled. 2Lux
Operating voltage 220 ~ 240 VAC 50/60Hz
Sensor Specification Rated load 400W (Capacitive load) 800W (Resistive load)
Stand-by power <0.5W
Sensitivity 10% / 50% / 75% / 100%
Hold-time 5s / 90s / 5min / 15min
Daylight sensor 2lux / 10lux / 50lux, disable
Microwave frequency 5.8 GHz +/- 75MHz
Transmitting power <0.2mW
Detection range maximum (diameterx h eight): 10m x 6m
o o
Detection angle 30 ~ 150
Mounting height maximum 6m
o o
Working temperature -20 C ~ 60 C
IP rating IP20