FR20313
FR20313
FR20313
Pg. No.
Cummins Inc 2000Nm@1200rpm
Columbus, Indiana 47202-3005
ISM11E5 Curve Number CPL Code Date
http://www.cummins.com 420 FR20313 43282 22-Jun-2010 1
Compression Ratio: 16.2:1 Engine Configuration: D353027BX03
Fuel System: Celect Electronic Emission Certification: Euro 5
Cylinders: 6 Aspiration: Turbocharged and Aftercooled
Bore: 125 mm (4.92 in) Displacement: 10.8 L (659 in3)
Stroke: 147 mm (5.79 in)
Torque Output
RPM N-m lb-ft
1,000 1,695 1,250
1,100 1,910 1,409
1,200 2,000 1,475
1,300 1,961 1,446
1,400 1,928 1,422
1,500 1,875 1,383
1,600 1,767 1,303
1,700 1,667 1,230
1,800 1,575 1,162
1,900 1,515 1,117
Power Output
RPM kW hp
1,000 178 239
1,100 220 295
1,200 252 338
1,300 267 358
1,400 283 380
1,500 295 396
1,600 296 397
1,700 297 398
1,800 297 398
1,900 302 405
Curves shown above represent mature gross engine performance capabilities obtained and corrected in accordance with SAE J1349 conditions
of 100 kPa (29.61 in Hg) barometric pressure [90 m (300 ft) altitude], 25 deg C (77 deg F) inlet air temperature, and 1 kPa (0.30 in Hg) water
vapor pressure with No. 2 diesel fuel.
Wang Qiang
Customer Engineering Certified within 5% Preliminary-(Estimated data)
Exhaust System
Maximum back pressure imposed by complete exhaust system 15 kPa 4.43 in-Hg
Cooling System
Maximum coolant temperature - engine out 100 deg C 212 deg F
Maximum charge air cooler outlet temperature (pumping mode)
Maximum temperature rise between charge air cooler putlet and ambient 30 deg C 54 deg F
Maximum coolant pressure (exclusive of pressure cap; closed thermostat at maximum
no load speed) 276 kPa 40 psi
Minimum cooling capability @ nominal fuel rate [Level II] with ram air speed and 50/50
E.G. coolant:
Engine out coolant to ambient @1200 66 deg C 119 deg F
Engine out coolant to ambient @1900 61 deg C 110 deg F
Maximum allowable pressure drop across charge air cooler and OEM CAC piping
(CACDP) 13 kPa 3.8 in-Hg
Maximum coolant temperature for engine protection controls 104 deg C 219 deg F
End of Report