Nothing Special   »   [go: up one dir, main page]

EC HyBlade 08 2010

Download as pdf or txt
Download as pdf or txt
You are on page 1of 52

EC_HyBlade_US_Edition_EN:Vorlage 12.08.

2010 13:45 Seite 1

EC axial fans - HyBlade® version 08/2010

US-edition

The engineer’s choice


EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 2

The new EC axial fans - HyBlade®

A new and unique hybrid blade design makes ebm-papst axial fans even quieter, more powerful and
lasting longer. The novel HyBlade® fan blades use a support structure made of highly robust,
corrosion-proof aluminium alloy and a coating made of special reinforced fibre plastics. Their aero-
dynamically optimal form results in enormous acoustic benefits at even higher efficiencies
compared to conventional blades. And this, in turn, offers further benefits when used in refrigera-
tion, heating and ventilation.

A revolutionary development
In refrigeration and ventilation, axial fans are frequently used, for
instance to cool heat exchangers with air passing through them. For
compact systems, the best tried and tested choice is the ebm-papst
external-rotor motor with the axial fan blades mounted onto its rotor.
Apart from compact dimensions, the fans in such applications are
expected to yield high air performance at minimal noise.

So far, fan blades are conventionally made of sheet steel or aluminium.


In order to meet exacting requirement for optimum efficiency and
acoustic behaviour, ebm-papst focused intensely on developing new
blade geometries. However, the limited design possibilities of a mono-
lithic sheet metal blade with uniform sheet thickness are obstacles
engineers have to simply accept.

To manage the required quantum leap and arrive at lower noise and
better efficiency, new construction principles and materials, or compo-
nent structures, to be more precise, are needed. This is the approach
ebm-papst took with its revolutionary hybrid blade concept, using hy-
brid components and structures to join seemingly irreconcilable cha-
racteristic in one harmonious functional unit.

The modular system consisting of motor, electronics and impeller allows for optimum configuration, making the new line of EC HyBlade® axial fans
unbeatable as to combinatorics and power range. The integrated motor electronics are based on state-of-the-art EC technology and correspond to the
“2nd generation”. This makes them highly efficient and they already comply with the latest standards of the defined European Efficiency Classes.

2
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 3

Table of contents

New EC axial fans - HyBlade® 2

GreenTech: The Green Company 4

Size 500 6

Size 560 10

Size 630 14

Size 710 20

Size 800 24

Size 910 28

Size 990 32

Electrical connections 36

Technical parameters & scope 40

ebm-papst representatives & subsidiaries 44

3
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 4

Sustainability is at the Centre of Our


Thoughts and Actions. Out of Conviction!

Eco-friendliness and sustainability have always been at the core of our thoughts and actions. For decades, we have worked
according to the simple but strict creed of our co-founder Gerhard Sturm: “Each new product we develop has to be better
than the last one in terms of economy and ecology.” GreenTech is the ultimate expression of our corporate philosophy.
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 5

GreenTech is pro-active development. GreenTech is acknowledged and certified.


Even in the design phase, the materials and processes we use are optimi- Every step in our chain of production meets the stringent standards of
sed for the greatest possible eco-friendliness, energy balance and – environmental specialists and the public. The 2008 Environmental Prize
wherever possible – recyclability. We continually improve the material of Baden-Wuerttemberg, the Green Award 2009, the Energy Efficiency
and performance of our products, as well as the flow and noise charac- Award 2009 of the dena – to give just a few examples – testify to this.
teristics. At the same time, we significantly reduce energy consumption. The environmental advantage gained in the performance of the products
Close cooperation with universities and scientific institutes and the pro- developed from our GreenTech philosophy can also be measured in the
fessorship we endow in the area of power engineering and regenerative fulfilment of the most stringent energy and environmental standards.
energies allows us to profit from the latest research findings in these In many instances, our products are already well below the thresholds
fields – and at the same time ensure highly qualified young academics. energy legislation will impose a few years from now – several times over.

GreenTech is ecofriendly production. Our customers profit from this every day.
GreenTech also stands for maximum energy efficiency in our production The heart of GreenTech is ebm-papst EC technology. The EC technology
processes. There, the intelligent use of industrial waste heat and ground- at the core of our most efficient motors and fans allows efficiency of up
water cooling, photovoltaics and, of course, our own cooling and venti - to 90%, saves energy at a very high level, significantly extends service
lation technology are of the utmost importance. Our most modern plant, life and makes our products maintenance-free. These values pay off not
for instance, consumes 91% less energy than currently specified and only for the environment, but every cent also pays off for the user! All
required. In this way, our products contribute to protecting the environ- ebm-papst products – even those for which EC technology does not (yet)
ment, from their origin to their recyclable packaging. make sense from an application viewpoint – feature the greatest possi-
ble connection of economy and ecology.

5
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 6

EC axial fans - HyBlade®


Ø 500

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Pressed-on round sheet steel plate, extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, B C D coated in black additionally
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "B" ("F" applying to the main components as per EN)
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


Max. operative range

electr. connections
Perm. amb. temp.
current draw (1)
power input (1)
voltage range

Speed/rpm (1)

Mass without
attachments
Blade angle

Frequency
Nominal
Curve

Max.

Max.
Nominal data
Type Motor VAC Hz rpm kW A Pa °C kg

*3G 500 M3G 084-GF 0° A 1~ 100-130 50/60 1080 0,38 3,30 105 -25..+60 6,2 p. 36 / K1)
*3G 500 M3G 112-EA 0° B 1~ 200-277 50/60 1420 0,75 3,40 175 -25..+60 7,2 p. 37 / L3)
*3G 500 M3G 112-GA 0° C 3~ 200-240 50/60 1600 0,98 3,20 200 -25..+60 9,2 p. 39 / K3)
*3G 500 M3G 112-GA 0° D 3~ 380-480 50/60 1600 0,98 1,60 200 -25..+60 9,2 p. 39 / K3)
subject to alterations (1) Nominal data in operating point with maximum load and 115 VAC or 230 VAC or 400 VAC

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]
0,80 [in H2O]

Air performance measured 1080 0,26 2,26 72


[Pa]

D A 1
C
as per: ISO 5801,
A 2 1080 0,30 2,61 68
200 4 Installation category A,
in ebm-papst full nozzle
A 3 1080 0,33 2,87 65
B
180 and without protection against A 4 1080 0,38 3,30 66
0,70

4 accidental contact
B 1 1420 0,55 2,51 78
160
Suction-side noise levels: B 2 1420 0,62 2,80 75
0,60

LwA as per ISO 13347, B 3 1420 0,68 3,03 73


140 3
LpA measured at 1 m distance B 4 1420 0,75 3,40 74
to fan axis
0,50

120 C 1 1600 0,73 2,32 80


A
3
The acoustic values given are C 2 1600 0,83 2,66 77
4
0,40

100 only valid under the measur-


C 3 1600 0,91 2,82 75
ment conditions listed and
may vary depending on the
C 4 1600 0,98 3,20 76
80
0,30

installation situation. D 1 1600 0,73 1,16 80


3 2

60 D 2 1600 0,83 1,33 77


2 With any deviation to the stan-
0,20

dard setup, the specific values


D 3 1600 0,91 1,41 75
40 have to be checked and re- D 4 1600 0,98 1,60 76
2
viewed once installed or fitted!
0,10

20
For detailed information
see page 40 ff.
1 1 1
0 1000 2000 3000 4000 5000 6000 [CFM]

2000 4000 6000 8000 10000 [m /h]


3

6
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 7

– Technical features: See electrical connections p. 36 ff.


– EMC: A B Interference emission acc. to EN 61000-6-3
C D Interference emission acc. to EN 61000-6-4

Interference immunity acc. to EN 61000-6-2


Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: GOST; UL/CSA are applied for; CCC on request
Direction of air flow

❮ "V" ❮ "V" ❮ "V"


Without With full With guard grille
attachments square nozzle for short nozzle

"V" on request W3G 500-GD09 -41 on request


"V" A3G 500-AM56 -21 W3G 500-GM56 -21 S3G 500-AM56 -21
"V" on request W3G 500-GN38 -11 on request
"V" A3G 500-AN33 -01 W3G 500-GN33 -01 S3G 500-AN33 -01
Direction of air flow "A" on request

7
Drawings Electr. connections
p. 8 ff. p. 36 ff.
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 8

EC axial fans - HyBlade®


Ø 500 with motor M3G084, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A on request 6,2
Depth of screw
111±2 4xM6 8-10 mm
104.7±3
45˚
Ø150±0.25

Ø497±1

4x90˚
Ø100
Ø178

0
600+2

Internal diameter of the


85

wall ring at least 503 mm


8

47.7 Ø164±0.35
160±2

Core-end sleeve
❮ "V"

Type Mass
With full square nozzle [kg]
A W3G 500-GD09 -41 12,2
156.5±5
Ø529

Ø11

16 615±1
120 656-3

❮ "V"
Type Mass
With guard grille for short nozzle [kg]
A on request 8,7

64±4
Ø521.4

Ø565

Internal diameter of the


wall ring at least 503 mm

5 Ø9
96 71,4±3

❮ "V"

8
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 9

EC axial fans - HyBlade®


Ø 500 with motor M3G112, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] g
B A3G 500-AM56 -21 7,2 160,5
C on request 9,2 180,5
116±3
112±2
D A3G 500-AN33 -01 9,2 180,5
5x
72
˚
Ø165±0.5
Ø200±1

Ø497±2

Internal diameter of the


0
800 + 2

wall ring at least 503 mm


85
8

56.5±0.6 5xM6
g±2 Ø186±0.5
Core-end sleeve
Depth of screw
❮ "V"
12-16 mm

Type Mass
With full square nozzle [kg]
B W3G 500-GM56 -21 17,2
171±5 C W3G 500-GN38 -11 19,2
D W3G 500-GN33 -01 19,2
Ø528

Ø11

16 615±1
120 656-3

❮ "V"
Type Mass
With guard grille for short nozzle [kg] t
B S3G 500-AM56 -21 10,5 52,0
C on request 12,5 72,0
64±4
D S3G 500-AN33 -01 12,5 72,0
Ø521

Ø565

Internal diameter of the


wall ring at least 503 mm

7 Ø9
108.5±3 t±3

❮ "V"

9
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 10

EC axial fans - HyBlade®


Ø 560

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: Counter-clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "B" ("F" applying to the main components as per EN)
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


Max. operative range

electr. connections
Perm. amb. temp.
current draw (1)
power input (1)
voltage range

Speed/rpm (1)

Mass without
attachments
Blade angle

Frequency
Nominal
Curve

Max.

Max.
Nominal data
Type Motor VAC Hz rpm kW A Pa °C kg

*3G 560 M3G 112-EA -5° A 1~ 200-277 50/60 1000 0,40 1,80 100 -25..+60 9,3 p. 36 / K1)
*3G 560 M3G 112-GA -5° B 3~ 200-240 50/60 1350 0,95 3,00 180 -25..+60 9,3 p. 39 / K3)
*3G 560 M3G 112-GA -5° C 3~ 380-480 50/60 1350 0,95 1,50 180 -25..+60 9,3 p. 39 / K3)
subject to alterations (1) Nominal data in operating point with maximum load and 230 VAC or 400 VAC

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

Air performance measured 1000 0,29 1,29 67


[in H2O]
[Pa]

A 1
B C as per: ISO 5801,
A 2 1000 0,34 1,48 66
180 4 Installation category A,
0,70

in ebm-papst full nozzle


A 3 1000 0,37 1,61 66
and without protection against A 4 1000 0,40 1,80 68
160
accidental contact
B 1 1350 0,67 2,22 75
0,60

140 Suction-side noise levels: B 2 1350 0,78 2,50 74


LwA as per ISO 13347, B 3 1350 0,86 2,74 73
0,50

LpA measured at 1 m distance


120
B 4 1350 0,95 3,00 77
3 to fan axis
A C 1 1350 0,67 1,11 75
0,40

100 4 The acoustic values given are C 2 1350 0,78 1,25 74


only valid under the measur- C 3 1350 0,86 1,37 73
ment conditions listed and
80 C 4 1350 0,95 1,50 77
0,30

may vary depending on the


3 installation situation.
60 2
0,20

With any deviation to the stan-


dard setup, the specific values
40
2 have to be checked and re-
viewed once installed or fitted!
0,10

20
For detailed information
see page 40 ff.
1 1
0 1000 2000 3000 4000 5000 6000 [CFM]

2000 4000 6000 8000 10000 [m3/h]

10
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 11

– Technical features: See electrical connections p. 36 ff.


– EMC: B C Interference emission acc. to EN 61000-6-3
A Interference emission acc. to EN 61000-6-4

Interference immunity acc. to EN 61000-6-2


Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: Variable
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: GOST; UL/CSA are applied for; CCC on request
Direction of air flow

❮ "V" ❮ "V" ❮ "V"


Without With full With guard grille
attachments square nozzle for short nozzle

"V" A3G 560-AP68 -21 W3G 560-GP68 -21 S3G 560-AP68 -21
"V" on request W3G 560-GQ49 -11 on request
"V" A3G 560-AQ41 -01 W3G 560-GQ41 -01 S3G 560-AQ41 -01
Direction of air flow "A" on request

11
Drawings Electr. connections
p. 12 p. 36 ff.
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 12

EC axial fans - HyBlade®


Ø 560 with motor M3G112, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] g
A A3G 560-AP68 -21 7,2 180,5
134±3
B on request 9,3 200,5
115±2 C A3G 560-AQ41 -01 9,3 200,5
5x
72
˚

Internal diameter of the


Ø165±0.5

Ø553±2
Ø200±1

wall ring at least 559 mm


20
800+
85
8

56.5±0.6 5xM6
g±2 Ø186 ±0.5
Depth of screw
Core-end sleeve 12-16 mm
❮ "V"

Type Mass
With full square nozzle [kg]
A W3G 560-GP68 -21 18,9
182.5±5
B W3G 560-GQ49 -11 21,0
C W3G 560-GQ41 -01 21,0
Ø625

Ø11

16 675±1
125 725-3
❮ "V"
Type Mass
With guard grille for short nozzle [kg] t
A S3G 560-AP68 -21 11,8 64
74±4 B on request 13,9 84
C S3G 560-AQ41 -01 13,9 84

Internal diameter of the


Ø645

Ø700

wall ring at least 559 mm

7 Ø9
116 t±3

❮ "V"

12
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 13

13
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 14

EC axial fans - HyBlade®


Ø 630

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades (5): A B C D E Pressed-on round sheet steel plate; F G Insertion part
made of sheet aluminium; Both versions extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, C D E F G coated in black additionally
– Direction of rotation: A B C D E counter-clockwise, F G clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: A B C D E "B" ("F" applying to the main components as per EN), F G "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


Max. operative range

electr. connections
Perm. amb. temp.
current draw (1)
power input (1)
voltage range

Speed/rpm (1)

Mass without
attachments
Blade angle

Frequency
Nominal
Curve

Max.

Max.
Nominal data
Type Motor VAC Hz rpm kW A Pa °C kg

*3G 630 M3G 084-GF 0° A 1~ 100-130 50/60 800 0,28 2,40 75 -25..+60 6,3 p. 36 / K1)
*3G 630 M3G 084-GF 0° B 1~ 200-277 50/60 800 0,28 1,20 75 -25..+60 6,3 p. 36 / K1)
*3G 630 M3G 112-GA -5° C 1~ 200-277 50/60 1000 0,72 3,20 140 -25..+60 9,3 p. 37 / L3)
*3G 630 M3G 112-IA -5° D 3~ 200-240 50/60 1140 0,97 3,20 170 -25..+60 11,3 p. 39 / K3)
*3G 630 M3G 112-IA -5° E 3~ 380-480 50/60 1140 0,97 1,60 170 -25..+60 11,3 p. 39 / K3)
*3G 630 M3G 150-IF 0° F 3~ 200-240 50/60 1450 2,95 8,90 270 -25..+60 24,4 p. 38 / L5)
*3G 630 M3G 150-IF 0° G 3~ 380-480 50/60 1510 3,20 5,00 290 -25..+65 24,4 p. 38 / L5)
subject to alterations (1) Nominal data in operating point with maximum load and 115 VAC or 230 VAC or 400 VAC

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

Air performance measured 800 0,18 1,64 65


[in H2O]
[Pa]

A 1
G
as per: ISO 5801,
A 2 800 0,23 2,04 63
F 4 Installation category A,
280
in ebm-papst full nozzle
A 3 800 0,27 2,34 63
4
and without protection against A 4 800 0,28 2,40 66
1,00

accidental contact
240 B 1 800 0,18 0,82 65
Suction-side noise levels:
B 2 800 0,23 1,02 63
LwA as per ISO 13347, B 3 800 0,27 1,17 63
0,80

200 LpA measured at 1 m distance


E
3 B 4 800 0,28 1,20 66
D to fan axis
3
4
C 1 1000 0,46 2,11 71
160 C The acoustic values given are C 2 1000 0,55 2,51 68
0,60

only valid under the measur-


4 C 3 1000 0,64 2,88 68
ment conditions listed and
C 4 1000 0,72 3,20 71
120 3 may vary depending on the
installation situation. D 1 1140 0,64 2,04 74
0,40

2
B 3 2 D 2 1140 0,78 2,50 71
A With any deviation to the stan-
80
4
dard setup, the specific values
D 3 1140 0,89 2,84 72
2
have to be checked and re- D 4 1140 0,97 3,20 74
0,20

3 2
40 viewed once installed or fitted!

2
For detailed information
see page 40 ff.
1 1 1 1 1
0 2000 4000 6000 8000 10000 12000 [CFM]

4000 8000 12000 16000 20000 [m /h]3

14
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 15

– Technical features: See electrical connections p. 36 ff.


– EMC: A B D E F G Interference emission acc. to EN 61000-6-3
C Interference emission acc. to EN 61000-6-4

Interference immunity acc. to EN 61000-6-2


Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: A B C D E Variable
– Terminal box: F G Electrical connection via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: A B C D E F GOST; UL/CSA are applied for; CCC on request
G GOST, UL/CSA; CCC on request
Direction of air flow

❮ "V" ❮ "V" ❮ "V"


Without With full With guard grille
attachments square nozzle for short nozzle

"V" on request W3G 630-GD10 -41 on request


"V" A3G 630-AD03 -A1 W3G 630-GD03 -A1 S3G 630-AD03 -A1
"V" A3G 630-AQ37 -21 W3G 630-GQ37 -21 S3G 630-AQ37 -21
"V" on request W3G 630-GR92 -11 on request
"V" A3G 630-AR85 -01 W3G 630-GR85 -01 S3G 630-AR85 -01
"V" on request W3G 630-GU29 -11 on request
"V" A3G 630-AU23 -01 W3G 630-GU23 -01 S3G 630-AU23 -01
Direction of air flow "A" on request

n P1 I LwA
[rpm] [kW] [A] [dB(A)]

E 1 1140 0,64 1,02 74


E 2 1140 0,78 1,25 71
E 3 1140 0,89 1,42 72
E 4 1140 0,97 1,60 74
F 1 1450 2,24 6,80 81
F 2 1450 2,45 7,50 80
F 3 1450 2,67 8,20 80
F 4 1450 2,95 8,90 84
G 1 1510 2,49 3,77 81
G 2 1510 2,74 4,18 81
G 3 1510 2,94 4,47 81
G 4 1510 3,20 5,00 85

15
Drawings Electr. connections
p. 16 ff. p. 36 ff.
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 16

EC axial fans - HyBlade®


Ø 630 with motor M3G084, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A on request 6,3
Depth of screw B A3G 630-AD03 -A1 6,3
112.3±2 4xM6
93±3 8-10 mm
45˚
Ø150±0.25

Ø626±1
Ø100

4x90˚
Ø178

Internal diameter of the


wall ring at least 634 mm
600+20
85
8

(47.7) Ø164±0.35
160 ±2

Core-end sleeve
❮ "V"

Type Mass
With full square nozzle [kg]
A W3G 630-GD10 -41 20,4
215±5
B W3G 630-GD03 -A1 20,4
Ø726

Ø11

20 750±1
142 805-3

❮ "V"
Type Mass
With guard grille for short nozzle [kg]
A on request 10,6
20.7±4 B S3G 630-AD03 -A1 10,6
Ø701.4

Ø750

Internal diameter of the


wall ring at least 634 mm

5 Ø9
146 21,4±3

❮ "V"

16
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 17

EC axial fans - HyBlade®


Ø 630 with motor M3G112, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] g
C A3G 630-AQ37 -21 9,3 180,5

144±3
D on request 11,3 200,5
123±2 E A3G 630-AR85 -01 11,3 200,5
5x
72
˚
Ø165±0.5
Ø200±1

Ø627±2

Internal diameter of the


wall ring at least 634 mm
20
800+
85
8

56.5±0.6 5xM6
g±2 Ø186±0.5

Core-end sleeve Depth of screw


❮ "V" 12-16 mm

Type Mass
With full square nozzle [kg]
C W3G 630-GQ37 -21 24,3
209±5
D W3G 630-GR92 -11 26,3
E W3G 630-GR85 -01 26,3
Ø726

Ø11

20 750±1
142 805-3

❮ "V"
Type Mass
With guard grille for short nozzle [kg] t
C S3G 630-AQ37 -21 14,6 39,5
60±4 D on request 16,6 59,5
E S3G 630-AR85 -01 16,6 59,5
Ø701

Ø750

Internal diameter of the


wall ring at least 634 mm

7 Ø9
141±3 t±3

❮ "V"

17
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 18

EC axial fans - HyBlade®


Ø 630 with motor M3G150, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
F on request 24,4
Depth of screw G A3G 630-AU23 -01 24,4
184±3
145±2 14xM10 max. 25 mm

8x
45
˚

22.5˚
Ø 627±2

Internal diameter of the


wall ring at least 634 mm


6x6
70 Ø232-2
250,5±1 Ø252±0.3
Ø275
Cable gland
❮ "V"

Type Mass
With full square nozzle [kg]
F W3G 630-GU29 -11 39,5
250±5 G W3G 630-GU23 -01 39,5
Ø696

Ø11

20 750±1
150 805-3

❮ "V"
Type Mass
With guard grille for short nozzle [kg]
F on request 31,5
76±4 G S3G 630-AU23 -01 31,5
Ø717.2

Ø750

Internal diameter of the


wall ring at least 634 mm

4 Ø10
178±3 72,5±3

❮ "V"

18
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:46 Seite 19

19
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 20

EC axial fans - HyBlade®


Ø 710

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: A B C counter-clockwise, D E clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: A B C "B" ("F" applying to the main components as per EN), D E "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


Max. operative range

electr. connections
Perm. amb. temp.
current draw (1)
power input (1)
voltage range

Speed/rpm (1)

Mass without
attachments
Blade angle

Frequency
Nominal
Curve

Max.

Max.
Nominal data
Type Motor VAC Hz rpm kW A Pa °C kg

*3G 710 M3G 112-IA 0° A 1~ 200-277 50/60 830 0,70 3,10 100 -25..+60 12,0 p. 37 / L3)
*3G 710 M3G 112-IA 0° B 3~ 200-240 50/60 900 0,93 3,00 125 -25..+60 12,0 p. 39 / K3)
*3G 710 M3G 112-IA 0° C 3~ 380-480 50/60 900 0,93 1,50 125 -25..+60 12,0 p. 39 / K3)
*3G 710 M3G 150-IF 0° D 3~ 200-240 50/60 1230 2,65 8,10 240 -25..+60 25,3 p. 38 / L5)
*3G 710 M3G 150-IF 0° E 3~ 380-480 50/60 1250 2,83 4,30 240 -25..+60 25,3 p. 38 / L5)
subject to alterations (1) Nominal data in operating point with maximum load and 230 VAC or 400 VAC

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

E Air performance measured 830 0,45 2,08 69


[in H2O]
[Pa]

A 1
D
as per: ISO 5801,
240 4 4 A 2 830 0,55 2,49 67
Installation category A,
A 3 830 0,64 2,86 68
0,90

in ebm-papst full nozzle


220
and without protection against A 4 830 0,70 3,10 73
accidental contact
0,80

200 B 1 900 0,59 1,92 70


Suction-side noise levels: B 2 900 0,70 2,28 69
180 3 3
0,70

LwA as per ISO 13347, B 3 900 0,81 2,60 70


160 LpA measured at 1 m distance B 4 900 0,93 3,00 76
0,60

to fan axis
140 C C 1 900 0,59 0,96 70
B
The acoustic values given are C 2 900 0,70 1,12 69
0,50

4
120 only valid under the measur-
A
C 3 900 0,81 1,30 70
ment conditions listed and
C 900 0,93 1,50 76
0,40

100 4 4
22 may vary depending on the
installation situation. D 1 1230 2,05 6,40 79
3
80
0,30

3 D 2 1230 2,33 7,20 78


With any deviation to the stan-
60 dard setup, the specific values
D 3 1230 2,56 7,80 79
0,20

2
have to be checked and re- D 4 1230 2,65 8,10 83
40
2 viewed once installed or fitted!
E 1 1250 2,23 3,40 79
0,10

20 E 2 1250 2,44 3,71 79


For detailed information

1 1 11
see page 40 ff. E 3 1250 2,67 4,06 79
0 2000 4000 6000 8000 10000 12000 14000 [CFM]
E 4 1250 2,83 4,30 83
4000 8000 12000 16000 20000 24000 [m /h]3

20
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 21

– Technical features: See electrical connections p. 37 ff.


– EMC: B C D E Interference emission acc. to EN 61000-6-3
A Interference emission acc. to EN 61000-6-4

Interference immunity acc. to EN 61000-6-2


Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: A B C Variable
– Terminal box: D E Electrical connection via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: A B C D GOST; UL/CSA are applied for; CCC on request
E GOST, UL/CSA; CCC on request
Direction of air flow

❮ "V" ❮ "V" ❮ "V"


Without With full With guard grille
attachments square nozzle for short nozzle

"V" A3G 710-AO85 -21 W3G 710-GO85 -21 S3G 710-AO85 -21
"V" on request W3G 710-GO87 -11 on request
"V" A3G 710-AO81 -01 W3G 710-GO81 -01 S3G 710-AO81 -01
"V" on request W3G 710-GU30 -11 on request
"V" A3G 710-AU21 -01 W3G 710-GU21 -01 S3G 710-AU21 -01
Direction of air flow "A" on request

21
Drawings Electr. connections
p. 22 ff. p. 37 ff.
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 22

EC axial fans - HyBlade®


Ø 710 with motor M3G112, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A A3G 710-AO85 -21 12,0
153±3 B on request 12,0
135±2
C A3G 710-AO81 -01 12,0
5x
72
˚
Ø165±0.5

Ø703±2
Ø200±1

Internal diameter of the


wall ring at least 710 mm
800+20
85
8

56.5 ±0.6 5xM6


200,5 ±2 Ø186±0.5
Depth of screw
Core-end sleeve 12-16 mm
❮ "V"

Type Mass
With full square nozzle [kg]
A W3G 710-GO85 -21 26,9
219,5±5 B W3G 710-GO87 -11 26,9
C W3G 710-GO81 -01 26,9
Ø792

Ø11

20 810±1
160 850-3

❮ "V"
Type Mass
With guard grille for short nozzle [kg]
A S3G 710-AO85 -21 18,8
41±4 B on request 18,8
C S3G 710-AO81 -01 18,8

Internal diameter of the


Ø799

Ø853

wall ring at least 710 mm

7 Ø9
169±3 31,5±3

❮ "V"

22
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 23

EC axial fans - HyBlade®


Ø 710 with motor M3G150, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
D on request 25,3
Depth of screw E A3G 710-AU21 -01 25,3
184±3 max. 25 mm
145±2 14xM10

8x
45
˚

22.5˚
Internal diameter of the
Ø 703 ±2

wall ring at least 710 mm


6x6

70 Ø232-2
250,5±1 Ø252±0.3
Cable Ø275

gland
❮ "V"

Type Mass
With full square nozzle [kg]
D W3G 710-GU30 -11 42,4
284,5±5 E W3G 710-GU21 -01 42,4
Ø772

Ø14,5

20 810±1
170 850-3

❮ "V"
Type Mass
With guard grille for short nozzle [kg]
D on request 34,5
31±4 E S3G 710-AU21 -01 34,5
Ø820.2

Internal diameter of the


Ø853

wall ring at least 710 mm

4 Ø10
223,5±3 27±3

❮ "V"

23
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 24

EC axial fans - HyBlade®


Ø 800

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades (5): A B C Pressed-on round sheet steel plate; D E F G Insertion part
made of sheet aluminium; Both versions extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Direction of rotation: clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: A B C "B" ("F" applying to the main components as per EN), D E F G "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


Max. operative range

electr. connections
Perm. amb. temp.
current draw (1)
power input (1)
voltage range

Speed/rpm (1)

Mass without
attachments
Blade angle

Frequency
Nominal
Curve

Max.

Max.
Nominal data
Type Motor VAC Hz rpm kW A Pa °C kg

*3G 800 M3G 112-IA 0° A 1~ 200-277 50/60 710 0,73 3,20 100 -25..+60 12,1 p. 37 / L3)
*3G 800 M3G 112-IA 0° B 3~ 200-240 50/60 735 0,84 2,80 110 -25..+60 12,1 p. 39 / K3)
*3G 800 M3G 112-IA 0° C 3~ 380-480 50/60 735 0,84 1,40 110 -25..+60 12,1 p. 39 / K3)
*3G 800 M3G 150-IF 0° D 3~ 200-240 50/60 1020 2,40 7,50 210 -25..+60 25,9 p. 38 / L5)
*3G 800 M3G 150-IF 0° E 3~ 380-480 50/60 1020 2,56 3,90 230 -25..+60 25,9 p. 38 / L5)
*3G 800 M3G 150-NA 0° F 3~ 200-240 50/60 1090 2,98 9,00 260 -25..+65 30,4 p. 38 / L5)
*3G 800 M3G 150-NA 0° G 3~ 380-480 50/60 1090 2,98 4,50 260 -25..+65 30,4 p. 38 / L5)
subject to alterations (1) Nominal data in operating point with maximum load and 230 VAC or 400 VAC

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

Air performance measured 710 0,46 2,15 70


[in H2O]
[Pa]

A 1
as per: ISO 5801,
280 G A 2 710 0,55 2,49 66
F Installation category A,
4 in ebm-papst full nozzle
A 3 710 0,63 2,84 64
1,00

E and without protection against A 4 710 0,73 3,20 69


240 D
accidental contact
4' B 1 735 0,52 1,76 70
4 Suction-side noise levels: B 2 735 0,62 2,04 66
0,80

200 LwA as per ISO 13347, B 3 735 0,72 2,36 64


LpA measured at 1 m distance B 4 735 0,84 2,80 70
3 to fan axis
160
C 1 735 0,52 0,88 70
3
0,60

The acoustic values given are C 2 735 0,62 1,02 66


only valid under the measur-
C
C 3 735 0,72 1,18 64
B ment conditions listed and
120 C 4 735 0,84 1,40 70
A may vary depending on the
4
0,40

4 installation situation. D 1 1020 1,62 4,94 75


2 D 2 1020 1,88 5,76 75
80 2 With any deviation to the stan-
3
3 dard setup, the specific values
D 3 1020 2,15 6,58 77
have to be checked and re- D 4 1020 2,40 7,50 85
0,20

40 viewed once installed or fitted!


2 2

For detailed information


see page 40 ff.
1 1 1 1
0 2000 4000 6000 8000 10000 12000 14000 16000 [CFM]

5000 10000 15000 20000 25000 [m3/h]

24
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 25

– Technical features: See electrical connections p. 37 ff.


– EMC: B C D E F G Interference emission acc. to EN 61000-6-3
A Interference emission acc. to EN 61000-6-4

Interference immunity acc. to EN 61000-6-2


Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: A B C Variable
– Terminal box: D E F G Electrical connection via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: A B C D F GOST; UL/CSA are applied for; CCC on request
E G GOST, UL/CSA; CCC on request
Direction of air flow

❮ "V" ❮ "V" ❮ "V"


Without With full With guard grille
attachments square nozzle for full nozzle

"V" A3G 800-AO81 -21 W3G 800-GO81 -21 S3G 800-BO81 -21
"V" on request W3G 800-GO91 -11 on request
"V" A3G 800-AO84 -01 W3G 800-GO84 -01 S3G 800-BO84 -01
"V" on request W3G 800-GU24 -11 on request
"V" A3G 800-AU25 -01 W3G 800-GU25 -01 S3G 800-BU25 -01
"V" on request W3G 800-GV10 -11 on request
"V" A3G 800-AV01 -01 W3G 800-GV01 -01 S3G 800-BV01 -01
Direction of air flow "A" on request

n P1 I LwA
[rpm] [kW] [A] [dB(A)]

E 1 1020 1,62 2,47 75


E 2 1020 1,88 2,88 75
E 3 1020 2,15 3,29 77
E 4’ 1020 2,56 3,90 85
F 1 1090 1,87 5,68 76
F 2 1090 2,18 6,64 76
F 3 1090 2,50 7,62 78
F 4 1090 2,98 9,00 84
G 1 1090 1,87 2,84 76
G 2 1090 2,18 3,32 76
G 3 1090 2,50 3,81 78
G 4 1090 2,98 4,50 84

25
Drawings Electr. connections
p. 26 ff. p. 37 ff.
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 26

EC axial fans - HyBlade®


Ø 800 with motor M3G112, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A A3G 800-AO81 -21 12,1
126±3 B on request 12,1
131±2
C A3G 800-AO84 -01 12,1
5x
72
˚
Ø165±0.5

Ø786±2
Ø200±1

Internal diameter of the


wall ring at least 795 mm
800 +20
85
8

56.5±0.6 5xM6
200,5±2 Ø186±0.5
Depth of screw
Core-end sleeve 12-16 mm
❮ "V"

Type Mass
With full square nozzle [kg]
A W3G 800-GO81 -21 33,3
236.5±5 B W3G 800-GO91 -11 33,3
C W3G 800-GO84 -01 33,3
Ø857

Ø14.5

17 910±1
190 970-3

❮ "V"
Type Mass
With guard grille for full nozzle [kg]
A S3G 800-BO81 -21 18,3

X 92 X
B on request 18,3
126±4
C S3G 800-BO84 -01 18,3
7.5

26
15

15.5
68
Ø816+2
Ø860

Internal diameter of the


wall ring at least 795 mm

66 144±3

❮ "V"

26
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 27

EC axial fans - HyBlade®


Ø 800 with motor M3G150, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] g
D on request 25,9 250,5
Depth of screw E A3G 800-AU25 -01 25,9 250,5
189±3
148±2 14xM10 max. 25 mm F on request 30,4 289,5
G A3G 800-AV01 -01 30,4 289,5

8x
45
˚

22.5˚
Ø788±2

Internal diameter of the


wall ring at least 795 mm


6x6

70 Ø232-2
g ±1 Ø252±0.3
Cable Ø275

gland
❮ "V"
Type Mass
With full square nozzle [kg]
D W3G 800-GU24 -11 45,7
307±5
E W3G 800-GU25 -01 45,7
F W3G 800-GV10 -11 50,2
G W3G 800-GV01 -01 50,2
Ø857

Ø14.5

17 910±1
190 970-3

❮ "V"
Type Mass
With guard grille for full nozzle [kg] t
D on request 33,7 124,0
132±4 X 92 X E S3G 800-BU25 -01 33,7 124,0
F on request 38,2 163,0
S3G 800-BV01 -01
7.5

G 38,2 163,0
15
26

15.5
68
Ø816+2
Ø860

Internal diameter of the


wall ring at least 795 mm

126,5±3 t±3

❮ "V"

27
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 28

EC axial fans - HyBlade®


Ø 910

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades (5): A B C Pressed-on round sheet steel plate; D E F G Insertion part
made of sheet aluminium; Both versions extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Direction of rotation: clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: A B C "B" ("F" applying to the main components as per EN), D E F G "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


Max. operative range

electr. connections
Perm. amb. temp.
current draw (1)
power input (1)
voltage range

Speed/rpm (1)

Mass without
attachments
Blade angle

Frequency
Nominal
Curve

Max.

Max.
Nominal data
Type Motor VAC Hz rpm kW A Pa °C kg

*3G 910 M3G 112-IA 0° A 1~ 200-277 50/60 590 0,58 2,60 80 -25..+60 12,2 p. 37 / L3)
*3G 910 M3G 112-IA 0° B 3~ 200-240 50/60 610 0,63 2,20 85 -25..+60 12,2 p. 39 / K3)
*3G 910 M3G 112-IA 0° C 3~ 380-480 50/60 610 0,63 1,10 85 -25..+60 12,2 p. 39 / K3)
*3G 910 M3G 150-IF 0° D 3~ 200-240 50/60 885 2,10 6,40 160 -25..+60 26,4 p. 38 / L5)
*3G 910 M3G 150-IF 0° E 3~ 380-480 50/60 885 2,10 3,20 160 -25..+60 26,4 p. 38 / L5)
*3G 910 M3G 150-NA 0° F 3~ 200-240 50/60 960 2,47 7,60 170 -25..+60 30,9 p. 38 / L5)
*3G 910 M3G 150-NA 0° G 3~ 380-480 50/60 1000 2,88 4,40 190 -25..+65 30,9 p. 38 / L5)
subject to alterations (1) Nominal data in operating point with maximum load and 230 VAC or 400 VAC

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]
G
Air performance measured 590 0,35 1,64 67
[in H2O]
[Pa]

A 1
4 as per: ISO 5801,
A 2 590 0,43 1,97 66
180 F Installation category A,
0,70

E in ebm-papst full nozzle


A 3 590 0,50 2,26 66
D 4
and without protection against A 4 590 0,58 2,60 71
160 4
accidental contact
B 1 610 0,39 1,38 68
0,60

140 Suction-side noise levels: B 2 610 0,48 1,40 67


3
LwA as per ISO 13347, B 3 610 0,56 1,84 66
0,50

LpA measured at 1 m distance


120
B 4 610 0,63 2,20 70
to fan axis
3 C 1 610 0,39 0,69 68
3
0,40

100 The acoustic values given are C 2 610 0,48 0,80 67


C
B only valid under the measur-
A
C 3 610 0,56 0,92 66
4 ment conditions listed and
80 4 C 4 610 0,63 1,10 70
0,30

may vary depending on the


2
installation situation. D 1 885 1,36 4,14 76
60
3
2 2 D 2 885 1,60 4,86 75
0,20

3 With any deviation to the stan-


dard setup, the specific values
D 3 885 1,83 5,58 75
40
have to be checked and re- D 4 885 2,10 6,40 78
2 2 viewed once installed or fitted!
0,10

20
For detailed information
see page 40 ff.
1 1 1 1 1
0 5000 10000 15000 [CFM]

5000 10000 15000 20000 25000 30000 [m3/h]

28
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 29

– Technical features: See electrical connections p. 37 ff.


– EMC: B C D E F G Interference emission acc. to EN 61000-6-3
A Interference emission acc. to EN 61000-6-4

Interference immunity acc. to EN 61000-6-2


Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Cable exit: A B C Variable
– Terminal box: D E F G Electrical connection via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: A B C D F GOST; UL/CSA are applied for; CCC on request
E G GOST, UL/CSA; CCC on request
Direction of air flow

❮ "V" ❮ "V" ❮ "V"


Without With full With guard grille
attachments square nozzle for full nozzle

"V" A3G 910-AO84 -21 W3G 910-GO84 -21 S3G 910-BO84 -21
"V" on request W3G 910-GO90 -11 on request
"V" A3G 910-AO83 -01 W3G 910-GO83 -01 S3G 910-BO83 -01
"V" on request W3G 910-GU31 -11 on request
"V" A3G 910-AU22 -01 W3G 910-GU22 -01 S3G 910-BU22 -01
"V" on request W3G 910-GV06 -11 on request
"V" A3G 910-AV02 -01 W3G 910-GV02 -01 S3G 910-BV02 -01
Direction of air flow "A" on request

n P1 I LwA
[rpm] [kW] [A] [dB(A)]

E 1 885 1,36 2,07 76


E 2 885 1,60 2,43 75
E 3 885 1,83 2,79 75
E 4 885 2,10 3,20 78
F 1 960 1,64 5,00 78
F 2 960 1,94 6,00 77
F 3 960 2,21 6,80 77
F 4 960 2,47 7,60 80
G 1 1000 1,92 2,91 79
G 2 1000 2,29 3,49 78
G 3 1000 2,60 3,97 79
G 4 1000 2,88 4,40 82

29
Drawings Electr. connections
p. 30 ff. p. 37 ff.
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 30

EC axial fans - HyBlade®


Ø 910 with motor M3G112, drawings for direction of air flow "V"

Type Mass
Without attachments [kg]
A A3G 910-AO84 -21 12,2
139±3
114±2
B on request 12,2
5x
C A3G 910-AO83 -01 12,2
72
˚

Internal diameter of the


Ø165±0.5
Ø200±1

Ø905±2

wall ring at least 913 mm


800 +20
85
8

56.5±0.6 5xM6
200,5±2 Ø186±0.5

Depth of screw
Core-end sleeve 12-16 mm
❮ "V"

Type Mass
With full square nozzle [kg]
A W3G 910-GO84 -21 37,0
266.5±5 B W3G 910-GO90 -11 37,0
C W3G 910-GO83 -01 37,0
Ø976

Ø14.5

20 1010±1
205 1070-3

❮ "V"
Type Mass
With guard grille for full nozzle [kg]
A S3G 910-BO84 -21 19,8
X 106 X B on request 19,8
135±4
C S3G 910-BO83 -01 19,8
10.5

15.8
26

22
74

Internal diameter of the


wall ring at least 913 mm
Ø932+2
Ø976

70 140±3

❮ "V"

30
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 31

EC axial fans - HyBlade®


Ø 910 with motor M3G150, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] g
D on request 26,4 250,0
188±3 Depth of screw E A3G 910-AU22 -01 26,4 250,5
115±2 14xM10 on request
max. 25 mm F 30,9 289,5
G A3G 910-AV02 -01 30,9 289,5

8x
45
˚

22.5˚
Internal diameter of the
Ø905±2

wall ring at least 913 mm


6x6
70 Ø232-2
g±1 Ø252±0.3
Cable Ø275
gland
❮ "V"

Type Mass
With full square nozzle [kg]
D W3G 910-GU31 -11 51,6
307±5
E W3G 910-GU22 -01 51,6
F W3G 910-GV06 -11 56,1
G W3G 910-GV02 -01 56,1
Ø976

Ø14.5

20 1010±1
205 1070-3

❮ "V"
Type Mass
With guard grille for full nozzle [kg] t
D on request 35,2 137,5
X S3G 910-BU22 -01
137±4 X 106 E 35,2 137,5
F on request 39,7 176,5
S3G 910-BV02 -01
10.5

39,7 176,5
15.8

G
26

22
74

Internal diameter of the


Ø931+2
Ø983

wall ring at least 913 mm

113±3 t±3

❮ "V"

31
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 32

EC axial fans - HyBlade®


Ø 990

– Material: Guard grille: Steel, phosphated and coated in black plastic


Wall ring: Sheet steel, pre-galvanised and coated in black plastic
Blades: Insertion part made of sheet aluminium, extrusion-coated in PP plastics
Rotor: Coated in black
Electronics enclosure: Die-cast aluminium, coated in black
– Number of blades: 5
– Direction of rotation: clockwise, seen on rotor
– Type of protection: IP 54 (acc. to EN 60529)
– Insulation class: "F"
– Mounting position: Shaft horizontal or rotor on bottom; rotor on top on request
– Condensate discharges: Rotor-side
– Mode of operation: Continuous operation (S1)
– Bearings: Maintenance-free ball bearings

Technical features and


Max. operative range

electr. connections
Perm. amb. temp.
current draw (1)
power input (1)
voltage range

Speed/rpm (1)

Mass without
attachments
Blade angle

Frequency
Nominal
Curve

Max.

Max.
Nominal data
Type Motor VAC Hz rpm kW A Pa °C kg

*3G 990 M3G 150-IF -5° A 3~ 200-240 50/60 820 1,64 5,00 135 -25..+60 25,7 p. 38 / L5)
*3G 990 M3G 150-IF -5° B 3~ 380-480 50/60 820 1,64 2,50 135 -25..+60 25,7 p. 38 / L5)
*3G 990 M3G 150-NA -5° C 3~ 200-240 50/60 960 2,58 8,00 180 -25..+65 31,2 p. 38 / L5)
*3G 990 M3G 150-NA -5° D 3~ 380-480 50/60 960 2,58 4,00 180 -25..+70 31,2 p. 38 / L5)
subject to alterations (1) Nominal data in operating point with maximum load and 400 VAC

n P1 I LwA
Curves [rpm] [kW] [A] [dB(A)]

Air performance measured 820 0,98 2,98 80


[in H2O]
[Pa]

A 1
D
C as per: ISO 5801,
A 2 820 1,22 3,70 78
180 4 Installation category A,
0,70

in ebm-papst full nozzle


A 3 820 1,46 4,46 78
and without protection against A 4 820 1,64 5,00 79
160
accidental contact
B 1 820 0,98 1,49 80
0,60

B
A B 2 820 1,22 1,85 78
140 Suction-side noise levels:
4
LwA as per ISO 13347, B 3 820 1,46 2,23 78
0,50

LpA measured at 1 m distance


120 3
B 4 820 1,64 2,50 79
to fan axis
C 1 960 1,49 4,54 85
0,40

100 The acoustic values given are C 2 960 1,90 5,76 83


3 only valid under the measur-
C 3 960 2,26 6,86 84
ment conditions listed and
80 C 4 960 2,58 8,00 85
0,30

may vary depending on the


installation situation. D 1 960 1,49 2,27 85
60 2
D 2 960 1,90 2,88 83
0,20

With any deviation to the stan-


2 dard setup, the specific values
D 3 960 2,26 3,43 84
40
have to be checked and re- D 4 960 2,58 4,00 85
viewed once installed or fitted!
0,10

20
For detailed information
see page 40 ff.
1 1
0 5000 10000 15000 [CFM]

5000 10000 15000 20000 25000 30000 [m3/h]

32
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 33

– Technical features: See electrical connections p. 38


– EMC: Interference emission acc. to EN 61000-6-3
Interference immunity acc. to EN 61000-6-2
Harmonics acc. to EN 61000-3-2/3
– Leakage current: < 3.5 mA acc. to EN 61800-5-1
– Terminal box: Electrical connection via terminal strip
– Protection class: I (acc. to EN 61800-5-1)
– Product conforming to standards: CE
– Approvals: A C GOST; UL/CSA are applied for; CCC on request
B D GOST, UL/CSA; CCC on request
Direction of air flow

❮ "V" ❮ "V" ❮ "V"


Without With full With guard grille
attachments square nozzle for full nozzle

"V" on request W3G 990-GY32 -11 on request


"V" A3G 990-AY28 -01 W3G 990-GY28 -01 S3G 990-BY28 -01
"V" on request W3G 990-GZ09 -11 on request
"V" A3G 990-AZ02 -01 W3G 990-GZ02 -01 S3G 990-BZ02 -01
Direction of air flow "A" on request

33
Drawings Electr. connections
p. 34 p. 38
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 34

EC axial fans - HyBlade®


Ø 990 with motor M3G150, drawings for direction of air flow "V"

Type Mass
Without attachments [kg] g h
A on request 25,7 238,0 57,5
Depth of screw B A3G 990-AY28 -01 25,7 238,0 57,5
175±3
106±2 14xM10 max. 25 mm
C on request 31,2 289,5 70,0
D A3G 990-AZ02 -01 31,2 289,5 70,0

8x
45
˚

22,5˚
Internal diameter of the
Ø990±2

wall ring at least 1000 mm


6x 6
h Ø232-2
g±1 Ø252±0,3
Cable gland Ø275
❮ "V"

Type Mass
With full square nozzle [kg] u
A W3G 990-GY32 -11 55,9 323,5
u±5
B W3G 990-GY28 -01 55,9 323,5
C W3G 990-GZ09 -11 61,4 336,0
D W3G 990-GZ02 -01 61,4 336,0
Ø1063

Ø14.5

20 1110±1
225 1170-3

❮ "V"
Type Mass
With guard grille for full nozzle [kg] s t
A on request 35,7 103,5 134,5
129±4 X 106 X B S3G 990-BY28 -01 35,7 103,5 134,5
C on request 41,2 116,0 173,5
10.5

15.8
26

D S3G 990-BZ02 -01 41,2 116,0 173,5


22
74

Internal diameter of the


Ø1018+2

wall ring at least 1000 mm


Ø1070

s±3 t±3

❮ "V"

34
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 35

35
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 36

Electrical connections EC
K1)

Technical features:
• Control input 0-10 VDC / PWM
• Output 10 VDC max. 1.1 mA
• Alarm relay
• Electronics / motor overtemperature protection
• Line undervoltage detection
• Motor current limitation
• Locked-rotor protection
• Soft start

Notes on various control possibilities and their applications


Umin = 15 V

Imax = L
10 mA Mains black +
50/60 Hz N
blue -
PE
green/yellow

NC
Alarm relay:
white1
Break for failure
+ COM
(2 A, 250 VAC, AC1)
PWM U white2
- Voltage output
10 K
red +10 V
max. 1.1 mA
12 V

Lin/PWM control input


yellow 0-10 VDC /
PWM
1 µF
GND
blue
Speed setting Speed setting Full speed Speed setting
with variable
PWM 1 - 10 kHz resistance 1 V - 10 V

100% PWM -> n=max 10 V -> n=max


approx. 10% PWM -> n=min approx. 1 V -> n=min
< 10% PWM -> n=0 < 1 V -> n=0

start up at > 14% start up at > 1.4 V

Customer circuit Connection Fan

Line 1 Line 2
0-10 V
+10 V

PWM
COM

GND
NC
PE
N
L

black blue green/yellow white1 white2 red yellow blue

Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 L black Mains 50/60 Hz, phase 2 +10 V red Voltage output +10 V max. 1.1 mA
N blue Mains 50/60 Hz, neutral 0-10 V / PWM yellow Control input (Impedance 100 kΩ)
PE green/yel Protective earth GND blue GND
NC white1 Alarm relay, break for failure
COM white2 Alarm relay, COMMON

36
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 37

Electrical connections EC
L3)

Technical features:
• PFC (active)
• Control input 0-10 VDC / PWM
• Output 10 VDC max. 10 mA
• Alarm relay
• Electronics / motor overtemperature protection
• Line undervoltage detection
• Motor current limitation
• Locked-rotor protection, soft start

Full Speed
speed setting

8 8 PE
2
PE1
1-10 V
11 12 N AC1 P
10 V -> n = max 3
1 V -> n = min L AC2 N
<1 V -> n = 0 4
10 A (T)

A1
11
COM
5
NC
6
A2
14

0-10 V
Speed setting 8 0-10 V
with 47 K 47 K 470 nF
potentiometer
10 V
11 10 V
11 10
GND Imax=10 mA
12 0V

8
10 K

12

Customer circuit Connection Fan

Line 1 Line 2
0-10 V

+10 V
COM

GND
NC
PE

green/yellow blue black white1 white2 yellow red blue

Line Pin Connection Colour Assignment / function


1 2 PE green/yellow Protective earth
1 3 N blue Mains 50/60 Hz, neutral
1 4 L black Mains 50/60 Hz, phase
1 5 COM white1 Alarm relay, COMMON (2A, max. 250 VAC, min. 10 mA, AC1)
1 6 NC white2 Alarm relay, break for failure
2 8 0-10 V yellow Control input (Impedance 100 kΩ), SELV
2 11 +10 V red Voltage output 10 VDC (+/- 3%), max. 10 mA, supply voltage for external units (e.g. potentiometer), SELV
2 12 GND blue GND, SELV

37
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 38

Electrical connections EC
L5)

Technical features:
• PFC (passive) • RS485 MODBUS
• Integrated PID controller • Motor current limitation, alarm relay
• Control input 0-10 VDC or 4-20 mA • Line undervoltage / phase failure detection
• Input for sensor 0-10 V or 4-20 mA • Electronics / motor overtemperature protection
• Slave output 0-10 V max. 5 mA • Locked-rotor protection, soft start
• Output 20 VDC (+25 % / -10 %) max. 50 mA • Digital inputs for day/night switch,
• Output 10 VDC (+3 %) max. 10 mA enabling, cooling / heating

KL3 KL2 KL1


Ain2 U

+20 V

Ain2 I
Din2

Din3

Aout
GND

Ain1 U

+10 V

Ain1 I
RS B

COM
RS A

Din1
GND

NO

NC

PE

L1

L2

L3
Connector Connection Assignment / function Connector Connection Assignment / function
KL1 L3 Mains; L3 KL3 Din1 Digital input 1 (enabling / disabling of electronics),,
L2 Mains; L2 Enabling: Pin open or applied voltage 5...50 VDC
L1 Mains; L1 Disabling: Bridge to GND or applied voltage < 1 VDC
PE PE Protective earth Ain1 I Analogue set value input, 4-20 mA (impedance 100 Ω),
KL2 NC Alarm relay, break for failure only to be used as alternative to terminal Ain1 U
COM Alarm relay, COMMON (2A, 250 VAC, AC1) +10 V Supply for external potentiometer,
NO Alarm relay, make for failure 10 VDC (±3 %) max. 10 mA
Ain1U Analogue set value input, 0-10 V (impedance 100 kΩ),
only to be used as alternative to terminal Ain1 I
GND GND
RSB RS485 interface for MODBUS RTU; RS B
RSA RS485 interface for MODBUS RTU; RS A
Aout Analogue output 0-10 V max. 5 mA, reading of current
motor speed / current motor control factor
Ain2 I Analog. actual value input, 4-20mA (impedance 100Ω),
only to be used as alternative to terminal Ain2 U
+20 V Supply for external sensor,
20 VDC (+25 % / -10%) max. 40 mA
Ain2 U Analog. actual value input, 0-10 V (impedance 100 kΩ),
only to be used as alternative to terminal Ain2 I
GND GND
Din3 Digital input 3 (switch Normal / Inverse),
The preset effective direction of the integrated
controller can be selected via BUS or via digital input
Normal/Inverse.
Normal: Pin open or applied voltage 5...50 VDC
Inverse: Bridge to GND or applied voltage < 1 VDC
Din2 Digital input 2 (switch Day / Night),
The preset set of parameters can be selected via BUS
or via digital input Day/Night.
Day: Pin open or applied voltage 5...50 VDC
Night: Bridge to GND or applied voltage < 1 VDC

38
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 39

Electrical connections EC
K3)

Technical features:
• PFC (passive)
• Control input 0-10 VDC / PWM
• Output 10 VDC (±20 %) max. 10 mA
• Alarm relay
• Electronics / motor overtemperature protection
• Line undervoltage / phase failure detection
• Motor current limitation
• Locked-rotor protection, soft start

Notes on various control possibilities and their applications


Umin = 15 V
L1
Imax =
10 mA Mains L2 black +
50/60 Hz L3 black
black
-
PE
green/yellow

NC
Alarm relay:
white1
Break for failure
+ COM
(2 A, 250 VAC, AC1)
PWM U white2
- Voltage output
10 K
red +10 V
max. 10 mA
12 V

Lin/PWM control input


yellow 0-10 VDC /
PWM
1 µF
GND
blue
Speed setting Speed setting Full speed Speed setting
with variable
PWM 1 - 10 kHz resistance 1 V - 10 V

100% PWM -> n=max 10 V -> n=max


approx. 10% PWM -> n=min approx. 1 V -> n=min
< 10% PWM -> n=0 < 1 V -> n=0

start up at > 14% start up at > 1,4 V

Customer circuit Connection Fan

Line 1 Line 2
0-10 V
+10 V

PWM
COM

GND
NC
PE
L1

L2

L3

black black black green/yellow white1 white2 red yellow blue

Line Connection Colour Assignment / function Line Connection Colour Assignment / function
1 L1 black Mains; L1 2 +10 V red Voltage output +10 V max. 1.1 mA
L2 black Mains; L2 0-10 V / PWM yellow Control input (Impedance 100 kΩ)
L3 black Mains; L3 GND blue GND
PE green/yel Protective earth
NC white1 Alarm relay, break for failure
COM white2 Alarm relay, COMMON

39
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 40

Technical parameters & scope

High standards for all ebm-papst products


Here at ebm-papst, we constantly strive to further improve our products in order to be able to offer you the best
possible product for your application. Careful monitoring of the market ensures that technical innovations are
reflected in the improvements of our products.
Based on the technical parameters listed below and the ambience you want our product to operate in,
we here at ebm-papst can always work out the best solution for your specific application.

General performance parameters Service life


Any deviations from the technical data and parameters described here The service life of ebm-papst products depends on two major factors:
are listed on the product-specific data sheet. – The service life of the insulation system
– The service life of the bearing system
Type of protection The service life of the insulation system mainly depends on voltage level,
The type of protection is specified in the product-specific data sheets. temperature and ambient conditions, such as humidity and condensation.
The service life of the bearing system depends mainly on the thermal load
Insulation class on the bearing.
The insulation class is specified in the product-specific data sheets. The majority of our products use maintenance-free ball bearings for
any mounting position possible. As an option, sleeve bearings can be
Mounting position used, which is indicated on the product-specific data sheet wherever
The mounting position is specified in the product-specific data sheets. applicable.
The service life L10 of the ball bearings can be taken as approx. 40,000
Condensate discharge holes operating hours at an ambient temperature of 40 °C, yet this estimate
Information on the condensate discharge holes is provided in the can vary according to the actual ambient conditions.
product-specific data sheets. We will gladly provide you with a lifetime calculation taking into account
your specific operating conditions.
Mode of operation
The mode of operation is specified in the product-specific data sheets. Motor protection / thermal protection
Information on motor protection and thermal protection is provided in the
Protection class product-specific data sheets.
The protection class is specified in the product-specific data sheets.. Depending on motor type and field of application, the following protective
features are realised:
– Thermal overload protection (TOP), either in-circuit or external
– PTC with electronic diagnostics
– Impedance protection
– Thermal overload protection (TOP) with electronic diagnostics
– Current limitation via electronics
If an external TOP is connected, the customer has to make sure to
connect a conventional trigger device for switching it off.
Products without fitted TOP and without protection against improper use,
a motor protection complying with the valid standards has to be installed.

40
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 41

Left: Endurance test room


Middle: Shock test
Right: Chamber test rig

Mechanical strain / performance parameters Legal and normative directives


All ebm-papst products are subjected to comprehensive tests complying The products described in this catalogue are designed, developed and
with the normative specifications. In addition to this, the tests also reflect produced in keeping with the standards in place for the relevant product
the vast experience and expertise of ebm-papst. and, if known, the conditions governing the relevant fields of application.

Vibration test Standards


Vibration tests are carried out in compliance with Information on standards is provided in the product-specific data sheets.
– Vibration test in operation according to DIN IEC 68, parts 2-6
– Vibration test at standstill according to DIN IEC 68, parts 2-6 EMC
Information on EMC standards is provided in the product-specific data
Shock load sheets.
Shock load tests are carried out in compliance with Complying with the EMC standards has to be established on the final
– Shock load according to DIN IEC 68, parts 2-27 appliance, as different mounting situations can result in changed EMC
properties.
Balancing quality
Testing the balancing quality is carried out in compliance with Leakage current
– Residual imbalance according to DIN ISO 1940 Information on the leakage current is provided in the product-specific
– Standard balancing quality level G 6.3 data sheets.
Should you require a higher balancing quality level for your specific Measuring is according to IEC 60990.
application, please let us know and specify this when ordering your
product. Approvals
In case you require a specific approval for your ebm-papst product
Chemo-physical strain / performance parameters (VDE, UL, GOST, CCC, CSA, etc.) please let us know.
Should you have questions about chemo-physical strain, please direct Most of our products can be supplied with the relevant approval.
them to your ebm-papst contact. Information on existing approvals is provided in the product-specific
data sheets.
Fields of application, industries and applications
Our products are used in various industries and applications: Air performance measurements
Ventilation, air-conditioning and refrigeration technology, clean room All air performance measurements are carried out on suction side and on
technology, automotive and rail technology, medical and laboratory tech- chamber test beds conforming to the specifications as per ISO 5801 and
nology, electronics, computer and office technology, telecommunications, DIN 24163. The fans under test are installed in the measuring chamber at
household appliances, heating, machines and plants, drive engineering. free air intake and exhaust (installation category A) and are operated at
Our products are not designed for use in the aviation and aerospace nominal voltage, with AC also at nominal frequency, and without any
industry! additional components such as guard grilles.
As required by the standard, the air performance curves correspond to
an air density of 1.2 kg/m3.

41
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 42

Room for precision noise measuring

Measurement conditions for air and noise measurement


ebm-papst products are measured under the following conditions:
– Axial and diagonal fans in direction of rotation “V” in full nozzle and
without guard grille
– Backward curved centrifugal fans, free-running and with inlet nozzle
– Forward curved single and dual inlet centrifugal fans with housing

Noise measurements
All noise measurements are carried out in low-reflective test rooms with
reverberant floor. Thus the ebm-papst acoustic test chambers meet the
requirements of precision class 1 according to DIN EN ISO 3745. For noise
measurement, the fans being tested are placed in a reverberant wall and
operated at nominal voltage (for AC, also at nominal frequency) without
additional attachments such as the guard grille.

Sound pressure level and sound level


All acoustic values are established according to ISO 13347, DIN 45635
and ISO 3744/3745 to accuracy class 2 and given in A-rated form.
When the sound pressure level (Lp) is measured, the microphone is on
the intake side of the fan being tested, usually at a distance of 1 m on
the fan axis.
To measure the sound level (Lw), 10 microphones are distributed over
an enveloping surface on the intake side of the fan being tested
(see graphic). The sound level measured can be roughly calculated
1,5d

from the sound pressure level by adding 7 dB.


D

Measuring configuration as per ISO 13347-3 respectively DIN 45635-38:


10 measuring points
d≥D
3d

h = 1,5d ... 4,5d


Measurement area S = 6d2 + 7d (h + 1,5d)
2d

42
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 43

Adding multiple noise sources with the same level

15
[dB]
Adding 2 noise sources with the same volume results in a level increase of approx. 3 dB.
The noise characteristics of multiple identical fans can be determined in advance based on

Increase in sound pressure / sound power level


the noise values specified in the data sheet. This is shown in the diagram opposite.

10
9
Example: 8 A3G800 axial fans are on a condenser. According to the data sheet, the sound
pressure level of a fan is approximately 75 dB(A). The level increase measured from the dia-
gram is 9 dB. Thus the overall sound level of the installation can be expected to be 84 dB(A).

5
0 1 2 5 8 10 15 20 25

Number of sources of sound with identical level

Adding two noise sources with different levels


3
[dB]

The acoustic performance of two different fans can be predetermined based on the sound
levels given in the data sheet. This is shown in the diagram opposite.
Increase in sound pressure / sound power level

Example: There is an axial fan A3G800 with a sound pressure level of 75 dB(A) at the oper-
2

ating point and an axial fan A3G710 with 71 dB(A) in a ventilation unit. The level difference is
1,5

4 dB. The level increase can now be read in the diagram as approx. 1.5 dB. This means that
the overall sound level of the unit can be expected to be 76.5 dB(A).
1
0

0 4 8 12 16 20 24

Difference in level with two sources of sound [dB]

Distance laws
0
[dB]

Sound power level is independent of distance to the sound source. In contrast to this, sound
pressure level decreases the further away the noise source is. The adjacent diagram shows
-10

the decrease in level under far sound field conditions. Far sound field conditions apply when-
ever the distance between microphone and fan is big when compared to fan diameter and
Decrease in sound pressure level
-20

wavelength to be considered. For more information on far sound field, please consult the rele-
vant literature on this complex topic. Per doubling of distance, the level in the far sound field
-26

decreases by 6 dB. In the near field of the fan, other correlations apply and the decrease in
-30

levels can be considerably smaller. The following example only applies to far sound field
conditions and can vary strongly depending on the installation effects:
-40

With an axial fan A3G300, a sound pressure level of 65 dB(A) was measured at a distance of 1 2 5 10 20 50 100

Distance [m]
1 m. According to the adjacent diagram, at a distance of 20 m we would get a reduction by
26 dB, i.e. a sound pressure level of 39 dB(A).

43
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 44

fan agent

compact fan agent


ebm-papst representatives & subsidiaries
motor specialist

motor agent

Germany
ebm-papst ebm-papst ebm-papst
Mulfingen GmbH & Co. KG St. Georgen GmbH & Co. KG Landshut GmbH

Bachmühle 2 Hermann-Papst-Straße 1 Hofmark-Aich-Straße 25


D-74673 Mulfingen D-78112 St. Georgen D-84030 Landshut
Phone +49 7938 81-0 Phone +49 7724 81-0 Phone +49 871 707-0
Fax +49 7938 81-110 Fax +49 7724 81-1309 Fax +49 871 707-465
info1@de.ebmpapst.com info2@de.ebmpapst.com info3@de.ebmpapst.com

www.ebmpapst.com www.ebmpapst.com www.ebmpapst.com

Agencies Kassel Distributors


Dipl.-Ing. (FH) Ralph Brück
Berlin Frankfurt
Hoherainstraße 3 b
Dipl.-Ing. (TH) Jens Duchow R.E.D. Handelsgesellschaft mbH
D-35075 Gladenbach
Händelstraße 7 Gutenbergstraße 3
Phone +49 6462 4071-10
D-16341 Panketal D-63110 Rodgau - Jügesheim
Fax +49 6462 4071-11
Phone +49 30 944149-62 Phone +49 6106 841-0
Ralph.Brueck@de.ebmpapst.com
Fax +49 30 944149-63 Fax +49 6106 841-111
Jens.Duchow@de.ebmpapst.com Koblenz info@red-elektromechanik.de
Winfried Schaefer www.red-elektromechanik.de
Bielefeld
Hinter der Kirch 10
Dipl.-Ing. (FH) Wolf-Jürgen Weber Hamburg
D-56767 Uersfeld
Niehausweg 13 Breuell + Hilgenfeldt GmbH
Phone +49 2657 16-96
D-33739 Bielefeld Grützmühlenweg 40
Fax +49 2657 16-76
Phone +49 5206 91732-31 D-22339 Hamburg
Winfried.Schaefer@de.ebmpapst.com
Fax +49 5206 91732-35 Phone +49 40 538092-20
Wolf-Juergen.Weber@de.ebmpapst.com Munich Fax +49 40 538092-84
Dipl.-Wirt.-Ing. (FH) Jens Peter info@breuell-hilgenfeldt.de
Dortmund
Uhlandstraße 6
Dipl.-Ing. (FH) Hans-Joachim Pundt Munich
D-74427 Fichtenberg
Auf den Steinern 3 A. Schweiger GmbH
Phone +49 7971 260-180
D-59519 Möhnesee-Völlinghausen Ohmstraße 1
Fax +49 7971 260-221
Phone +49 2925 800-407 D-82054 Sauerlach
Jens.Peter@de.ebmpapst.com
Fax +49 2925 800-408 Phone +49 8104 897-0
Hans-Joachim.Pundt@de.ebmpapst.com Nuremberg Fax +49 8104 897-90
Friedrich Klein info@schweiger-gmbh.de
Frankfurt
Adlerstraße 49/1 www.schweiger-gmbh.com
Dipl.-Ing. Christian Kleffmann
D-73540 Heubach
Dr.-Hermann-Krause-Straße 23
Phone +49 7173 4983 (1 to 5 pieces)
D-63452 Hanau
Fax +49 7173 8053
Phone +49 6181 1898-12 North
Friedrich.Klein@de.ebmpapst.com
Fax +49 6181 1898-13 Breuell + Hilgenfeldt GmbH
Christian.Kleffmann@de.ebmpapst.com Offenburg Grützmühlenweg 40
Dipl.-Ing. (FH) Ralf Braun D-22339 Hamburg
Halle
Hubeneck 21 Phone +49 40 538092-20
Dipl.-Ing. (TU) Michael Hanning
D-77704 Oberkirch Fax +49 40 538092-84
Lerchenweg 4
Phone +49 7802 9822-52 ebmpapst@breuell-hilgenfeldt.de
D-06120 Lieskau
Fax +49 7802 9822-53
Phone +49 345 55124-56 South
Ralf.Braun@de.ebmpapst.com
Fax +49 345 55124-57 HDS Ventilatoren Vertriebs GmbH
Michael.Hanning@de.ebmpapst.com Stuttgart Glaswiesenstraße 1
Dipl.-Ing. (FH) Rudi Weinmann D-74677 Dörzbach
Hamburg
Hindenburgstraße 100/1 Phone +49 7937 8033520
Ingenieurbüro Breuell GmbH
D-73207 Plochingen Fax +49 7937 8033525
Ing. Dirk Kahl
Phone +49 7153 9289-80 info@hds-gmbh.net
Elektroingenieur
Fax +49 7153 9289-81
Grützmühlenweg 40
Rudi.Weinmann@de.ebmpapst.com
D-22339 Hamburg
Phone +49 40 538092-19 Ulm
Fax +49 40 538092-84 Dipl.-Wirt.-Ing. (FH) Axel Resch
Dirk.Kahl@de.ebmpapst.com Bachmühle 2
D-74673 Mulfingen
Phone +49 7938 81-7092
Fax +49 7938 81-110
Axel.Resch@de.ebmpapst.com

44
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:47 Seite 45

Europe Czech Republic / Slovakia Hungary


ebm-papst CZ s.r.o. ebm-papst Industries Kft.
Austria
Kaštanová 34a Ezred u. 2.
ebm-papst Motoren & Ventilatoren GmbH
CZ-620 00 Brno H-1044 Budapest
Straubingstraße 17
Phone +420 547 232-617 Phone +36 1 8722-190
A-4030 Linz
Fax +420 547 232-622 Fax +36 1 8722-194
Phone +43 732 321150-0
info@ebmpapst.cz office@hu.ebmpapst.com
Fax +43 732 321150-20
www.ebmpapst.cz
info@at.ebmpapst.com Iceland
www.ebmpapst.at Denmark RJ Engineers
ebm-papst Denmark ApS Stangarhyl 1A
Belarus
Vallensbækvej 21 IS-110 Reykjavik
ebm-papst Bel AgmbH
DK-2605 Brøndby Phone +354 567 8030
P.O. Box 117
Phone +45 43 631111 Fax +354 567 8015
BY-220138 Minsk
Fax +45 43 630505 rj@rj.is
Phone +375 17 3851556
mail@dk.ebmpapst.com www.rj.is
Fax +375 17 3851556
www.ebmpapst.dk
info@by.ebmpapst.com Ireland
www.ebmpapst.by Estonia ebm-papst Limited
ebm-papst Oy, Eesti Filiaal Portlaoise Business & Technology Park
Belgium
Kesk tee 13 Mountrath Road
ebm-papst Benelux B.V.
Aaviku küla, Jüri Tehnopark IRL-Portlaoise, Co. Laois
Sales office Belgium-Luxemburg
EST-75301 Rae Vald, Harjumaa Phone +353 5786 643-43
Romeinsestraat 6/0101
Phone +372 65569-78 Fax +353 5786 643-46
Research Park Haasrode
Fax +372 65569-79 sales@ie.ebmpapst.com
B-3001 Heverlee-Leuven
www.ebmpapst.ee www.ebmpapst.ie
Phone +32 16 396-200
Fax +32 16 396-220 Finland Italy
info@be.ebmpapst.com ebm-papst Oy ebm-papst Srl
www.ebmpapst.be Puistotie 1 Via Cornaggia 108
FIN-02760 Espoo I-22076 Mozzate (Co)
Bulgaria
Phone +358 9 887022-0 Phone +39 0331 836201
ebm-papst Romania S.R.L.
Fax +358 9 887022-13 Fax +39 0331 821510
Str. Tirnavei Nr. 20
mailbox@ebmpapst.fi info@it.ebmpapst.com
RO-500327 Brasov
www.ebmpapst.fi www.ebmpapst.it
Phone +40 268 312-805
Fax +40 268 312-805 France Macedonia
dudasludovic@xnet.ro ebm-papst SARL ebm-papst Industries Kft.
ZI Nord - rue A. Mohler Ezred u. 2.
Croatia
BP 62 H-1044 Budapest
ebm-papst Industries Kft.
F-67212 Obernai-Cedex Phone +36 1 8722-190
Ezred u. 2.
Phone +33 820 326266 Fax +36 1 8722-194
H-1044 Budapest
Fax +33 3 88673883 office@hu.ebmpapst.com
Phone +36 1 8722-190
info@ebmpapst.fr
Fax +36 1 8722-194
www.ebmpapst.fr
office@hu.ebmpapst.com
Greece
Helcoma
Th. Rotas & Co OE
Davaki 65
GR-17672 Kallithea-Attiki
Phone +30 210 9513-705
Fax +30 210 9513-490
contact@helcoma.gr
www.helcoma.gr

45
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:48 Seite 46

fan agent

compact fan agent


ebm-papst representatives & subsidiaries
motor specialist

motor agent

Netherlands Russia Switzerland


ebm-papst Benelux B.V. ebm-papst Ural GmbH ebm-papst AG
Engelseweg 127 Posadskaja-Strasse, 23(E), 3 Rütisbergstrasse 1
NL-5705 AC Helmond RU-620102 Ekaterinburg CH-8156 Oberhasli
Phone +31 492 502-900 Phone +7 343 2338000 Phone +41 44 73220-70
Fax +31 492 502-950 Fax +7 343 2337788 Fax +41 44 73220-77
verkoop@nl.ebmpapst.com Konstantin.Molokov@ru.ebmpapst.com verkauf@ebmpapst.ch
www.ebmpapst.nl www.ebmpapst.ur.ru www.ebmpapst.ch
Norway ebm-papst Rus GmbH Turkey
ebm-papst AS proezd 4529, vladenie 5, stroenie 1 Akantel Elektronik San. Tic. LTD. Sti.
P.B. 173 Holmlia RU-141000 Mytistschi, Oblast Moskau Atatürk Organize Sanayi
N-1203 Oslo Phone +7 495 9807524 Bölgesi 10007 SK. No.:6
Phone +47 22 763340 Fax +7 495 5140924 TR-35620 Cigli-Izmir
Fax +47 22 619173 info@ebmpapst.ru Phone +90 232 3282090
mailbox@ebmpapst.no www.ebmpapst.ru Fax +90 232 3280270
www.ebmpapst.no akantel@akantel.com.tr
Serbia & Montenegro
www.ebmpapst.com.tr
Poland ebm-papst Industries Kft.
ebm-papst Polska Sp. z o.o. Ezred u. 2. Ukraine
ul. Annopol 4A H-1044 Budapest ebm-papst Ukraine LLC
PL-03236 Warszawa Phone +36 1 8722-190 Lepse Boulevard, 4, Building 47
Phone +48 22 6757819 Fax +36 1 8722-194 UA-03067 Kiev
Fax +48 22 6769587 office@hu.ebmpapst.com Phone +38 044 2063091
office@ebmpapst.pl Fax +38 044 2063091
Spain
www.ebmpapst.pl mail@ebmpapst.ua
ebm-papst Ibérica S.L.
www.ebmpapst.ua
Portugal Avda. del Sistema Solar, 29
ebm-papst (Portugal), Lda. E-28830 San Fernando de Henares (Madrid) United Kingdom
Av. Marechal Gomes da Costa, 35 e Phone +34 91 6780894 ebm-papst UK Ltd.
Rua Conselheiro Emidio Navarro Fax +34 91 6781530 Chelmsford Business Park
P-1800-255 Lisboa ventas@ebmpapst.es GB-Chelmsford Essex CM2 5EZ
Phone +351 218 394-880 Phone +44 1245 468555
Sweden
Fax +351 218 394-759 Fax +44 1245 466336
ebm-papst AB
info@pt.ebmpapst.com sales@uk.ebmpapst.com
Äggelundavägen 2
www.ebmpapst.pt www.ebmpapst.co.uk
S-17562 Järfälla
Romania Phone +46 8 7619400 ebm-papst Automotive & Drives (UK) Ltd.
ebm-papst Romania S.R.L. Fax +46 8 362306 The Smithy
Str. Tirnavei Nr. 20 info@ebmpapst.se Fidlers Lane, East Ilsley
RO-500327 Brasov www.ebmpapst.se GB-Berkshire RG20 7LG
Phone +40 268 312-805 Phone +44 1635 2811-11
Fax +40 268 312-805 Fax +44 1635 2811-61
dudasludovic@xnet.ro A&Dsales@uk.ebmpapst.com
www.ebmpapst-ad.com

46
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:48 Seite 47

America USA Africa


ebm-papst Inc.
Argentina South Africa
P.O. Box 4009
ebm-papst de Argentina S.A. ebm-papst South Africa (Pty) Ltd.
100 Hyde Road
Hernandarias 148 Lomas del Mirador P.O. Box 3124
USA-Farmington, CT 06034
Pcia. de Buenos Aires (1752) 1119 Yacht Avenue
Phone +1 860 674-1515
Phone +54 11 46576135 ZA-2040 Honeydew
Fax +1 860 674-8536
Fax +54 11 46572092 Phone +27 11 794-3434
sales@us.ebmpapst.com
ventas@ar.ebmpapst.com Fax +27 11 794-5020
www.ebmpapst.us
www.ebmpapst.com.ar info@za.ebmpapst.com
ebm-papst Automotive & Drives, Inc. www.ebmpapst.co.za
Brasil
3200 Greenfield, Suite 255
ebm-papst Motores Ventiladores Ltda.
USA-Dearborn, MI 48120
Av. José Giorgi, 301 Galpões B6+B7
Phone +1 313 406-8080
Condominio Logical Center
Fax +1 313 406-8081
BR-06707-100 Cotia - São Paulo
automotive@us.ebmpapst.com
Phone +55 11 4613-8700
www.ebmpapst-automotive.us
Fax +55 11 3164-8924
vendas@br.ebmpapst.com
www.ebmpapst.com.br
Canada
ebm-papst Canada Inc.
1800 Ironstone Manor, Unit 2
CDN-Pickering, Ontario, L1W3J9
Phone +1 905 420-3533
Fax +1 905 420-3772
sales@ca.ebmpapst.com
www.ebmpapst.ca
Mexico
ebm Industrial S.de R.L. de C.V.
Paseo de Tamarindos 400-A-5to Piso
Col. Bosques de las Lomas
MEX-Mexico 05120, D.F.
Phone +52 55 3300-5144
Fax +52 55 3300-5243
sales@mx.ebmpapst.com
www.ebmpapst.com.mx

47
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:48 Seite 48

fan agent

compact fan agent


ebm-papst representatives & subsidiaries
motor specialist

motor agent

Asia Japan Thailand


ebm-papst Industries Japan K.K. ebm-papst Thailand Co., Ltd.
China
12 Floor, Benex S-3 Bldg. 99/349 Na-Nakorn Bldg., 4th Floor
ebm-papst Ventilator (Shanghai) Co., Ltd.
3-20-8 Shinyokohama, Kohoku-ku Chaeng Wattana Road, Thungsonghong,
No. 418, Huajing Road
J-222-0033 Yokohama THA-10210 Laksi, BKK
WaiGaoQiao Free Trade Zone
Phone +81 45 47057-51 Phone +66 2 57615-24
No. 2001, Yang Gao (N) Road
Fax +81 45 47057-52 Fax +66 2 57615-42
VRC-200131 Shanghai, P.R. of China
info@jp.ebmpapst.com salesdept@th.ebmpapst.com
Phone +86 21 5046-0183
www.ebmpapst.jp
Fax +86 21 5046-1119 United Arab Emirates
sales@cn.ebmpapst.com Korea ebm-papst Middle East FZE
www.ebmpapst.com.cn ebm-papst Korea Co. Ltd. PO Box 17755
6F, Trutec Bldg. Jebel Ali Free Zone / FZS1 / AP05
Hong Kong
B 6-2, Digital Media City (DMC) UAE-Dubai
ebm-papst Hong Kong Ltd.
Sangam-Dong, Mapo-Gu Phone +971 4 88608-26
Unit No. 13,9 / F
ROK-Seoul 121-270 Fax +971 4 88608-27
Technology Park, 18 On Lai Street
Phone +82 2 366213-24 info@ae.ebmpapst.com
Siu Lek Yuen, Shatin N.T.
Fax +82 2 366213-26 www.ebmpapst.ae
Hong Kong - P.R. of China
info@kr.ebmpapst.com
Phone +852 2145-8678 Vietnam
www.ebmpapst.co.kr
Fax +852 2145-7678 ebm-papst Vietnam
info@hk.ebmpapst.com Malaysia Representative Office
ebm-papst Malaysia Room #102, 25 Nguyen Van Thu Street
India
Representative Office District 1
ebm-papst India Pvt. Ltd.
Unit 12-2, Jalan USJ Sentral 3 VN-Ho Chi Minh City
26/3, G.N.T. Road, Erukkencherry
Persiaran Subang, Selangor Darul Ehsan Phone +84 8 39104099
IND-Chennai-600118
MAL-47600 Subang Jaya Fax +84 8 39103970
Phone +91 44 25372556
Phone +60 3 8024-1680 linh.nguyen@vn.ebmpapst.com
Fax +91 44 25371149
Fax +60 3 8024-8718
sales@in.ebmpapst.com
salesdept@my.ebmpapst.com
www.ebmpapst.in
Singapore
Indonesia
ebm-papst SEA Pte. Ltd.
ebm-papst Indonesia
No. 23 Ubi Road 4
Representative Office
#06-00 Olympia Industrial Building
German Centre, 4th Floor, Suite 4470
SGP-Singapore 408620
Jl. Kapt. Subijono Dj. Bumi Serpong Damai
Phone +65 65513789
RI-15321 Tangerang
Fax +65 68428439
Phone +62 21 5376250
salesdept@sg.ebmpapst.com
Fax +62 21 5388305
salesdept@id.ebmpapst.com Taiwan
ETECO Engineering & Trading Corp.
Israel
10F-I, No. 92, Teh-Wei Str.
Polak Bros. Import Agencies Ltd.
RC-Tsow-Inn District, Kaohsiung
9 Hamefalsim Street
Phone +886 7 557-4268
IL-Kiryat Arie, Petach-Tikva 49514
Fax +886 7 557-2788
Phone +972 3 9100300
eteco@ms22.hinet.net
Fax +972 3 5796679
www.ebmpapst.com.tw
polak@polak.co.il
www.polak.co.il

48
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:48 Seite 49

Australia
Australia
ebm-papst A&NZ Pty Ltd.
10 Oxford Road
AUS-Laverton North, Victoria, 3026
Phone +61 3 9360-6400
Fax +61 3 9360-6464
sales@ebmpapst.com.au
www.ebmpapst.com.au
New Zealand
ebm-papst A&NZ Pty Ltd.
102 Henderson Valley Road
NZ-Henderson, Auckland 1230
Phone +64 9 837-1884
Fax +64 9 837-1899
sales@ebmpapst.com.au
www.ebmpapst.com.au

49
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:48 Seite 50

Notes

50
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:48 Seite 51

51
EC_HyBlade_US_Edition_EN:Vorlage 12.08.2010 13:48 Seite 52

37845-7-8811 · RA-08/10-1’
Printed in Germany

ebm-papst
Mulfingen GmbH & Co. KG

Bachmühle 2
D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com

www.ebmpapst.com

You might also like