Nothing Special   »   [go: up one dir, main page]

AP DRAFT MM

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

A B C D F G H I J

CIVIL AND STRUCTURAL DRAWINGS CONSTRUCTION PROJECT MANAGEMENTS


ARCHITECTURAL DESIGNS AND PROJECT QUANTIFICATIONS
+256786914523/ +256753042992

GENERAL NOTES
1. This drawing is protected under the
copyright act and cannot be used or
16,322 reproduced in part or whole without authors
consent

15,922 2. All dimensions are in milimetres. Written


dimensions to be followed in preference to
scaled dimension
3. All construction work is to comply with the
200 200 200 200 200 latest Codes of practice and Local Authority
By-Laws

1,839 1,560 4,162 4,162 1,560 1,839 4. PVO denotes parmanent ventilation over
and must be provided above all doors and
windows where indicated or shown
5. All walls less than 200mm thick to be

6 6
reinforced with hoop iron at every alternate
200

200
course.
6.All reinforced concrete works to structural
engineer's details and specifications
1,164

7. All sanitary works must be in accordance

914
with Ministry of Health Rules and regulations
8. All levels shown are finished levels unless
otherwise stated
9. Provide a 600x200mm thick concrete as

5 5
splash apron around the perimeter of the wall
and all edges of splash apron to have a 20mm
TOILET TOILET chamfer

BEDROOM BEDROOM 10. Any discrepancies must be reported to the


1,170

Designer before work is put at hand.

REVISION HISTORY
3,962

RevID ChID Change Name Date

4 4

3,048
PORCH
ARCHITECT:
1,828

3 3
200

200
PROJECT:

10,124
9,824
F

F
7
DW

DW
8
9
6 CLIENT/OWNER:
LOUNGE 5
10
LOUNGE NAME:.............................................................
4,162

3,962

3,962
18G x 265
19R x 168
11
4 TEL:.................................................................

KITCHEN KITCHEN
12
3 SIGN:...............................................................
13 NOTES:
2 ROOF CONSTRUCTION NOTES
14 30 Degrees slope approved roofing sheet on
50x75mm timber purlins 800mm c/c on
1 50x100mm timber rafters at 1500mm c/c on
UP 50x100mm timber strut and ties on
15
50x150mm timber tie beam on
16 100x75mm timber wall plate
All timber to be treated with approved preservative
FLOOR CONSTRUCTION NOTES
17 ceramic tiles and ceramic tiles skirting on 100mm thick
mesh reinforced concrete on 1000 gauge DPM on 50mm
18 thick sand blinding on 200mm thick well compacted
hardcore on Well compacted and anti-termite treated soil

2 2
Pad foundations to be applied below all columns
200

200
19 according to the specification on structural drawings.
FOUNDATION CONSTRUCTION NOTES
DOWN 200mm thick walls in hard burnt bricks or concrete blocks
rendered and painted with two coats of bituminous
paint on 200mm thick concrete strip on50mm thick
sand blinding at a depth of not less than750mm
1,500

below ground level on well compacted andantitermite


1,500

1,500
treated soil.
The depth of the foundation to be determined on site and
refer to structural drawing.
CEILING NOTES
On first floor, 15mm thick cement-sand screed on
Metal lathing fixed on50x100mm
timber joists at 1200mm C/C and

1 1
50x50mm branderings at 600mm C/C
All timber to be treated with approved preservative

APPROVAL
APPROVED BY:...........................................

TEL:.................................................................

200 200 200 200 200 200 SIGN:...............................................................

1,639 4,572 2,500 4,572 1,639 DRAWN BY :.................................................


RUBANGAKENE MARVIN ANYWAR

+256786914523/+256753042992
TEL:.................................................................

SIGN:...............................................................

1,839 1,760 3,012 1,350 1,350 3,012 1,760 1,839 CHECKED BY:..............................................

TEL:.................................................................

A B C D F G H I J
SIGN:...............................................................

SCALES USED:

1:50 1:75

GSPublisherVersion 0.38.100.100