Safety Relay Combination: Series SCR
Safety Relay Combination: Series SCR
Safety Relay Combination: Series SCR
S21
S22
(+) (-) 13 23 33 41
Electr. Fuse
Transformer
K1
~ ~
≈ Monitoring Logic
= K2
+
K1 K2
14 24 34 42
Electrical Data
Supply voltage Ue 24 V AC/DC
Voltage range 0,90 ...1,1 UB
Frequency 50 ... 60 Hz
Power consumption appr. 24V DC: 3 W, 24V AC: 5 VA
Conductor data
2 x 1,5 mm2 solid wire
conductor connection 2 x 1,0 mm2 strand with wire end ferrule
DIN VDE 46228
Max. conductor length (input circuit) 2 x 100m (single channel), 4 x 100m (dual channel)
Conductor cross-section 2 x 1,5 mm2 / 4 x 1,5 mm2
Capacity 150 nF/km
Contact data
Contact configuration 3 N.O. contacts / 1 N.C. contact
Contact type Relay forcibly guided contacts
Contact material AgSnO2 flash gold or comparable material
Switching voltage 240 V AC, 24 V DC
Switching current 5A
Summation current 13,8 A
Utilization category (DIN EN 60947-5-1) AC 15 230 V / 5 A; DC 13 24 V / 5 A
Max. switching capacity 1200 VA (ohms load)
Mechanical life 107 operations
Electrical life 105 operations (DC 24V/2A)
Creapage and clearance distances (DIN VDE 0160) at pollution grade 2, Voltage category 3 / 250 V
Contact protection 6,3 A fast acting or 4 A slow acting DIN VDE 0660 Teil 200
Short Circuit Withstand acc. IEC60947-5-1 6A
Short Circuit Protection Device (SCPD, Fuse links),
gG acc. IEC IEC60269-1; IEC60269-3-1; VDE036-T301
size D01
Restarting readines time 0,5 s (minimum switch off time the inputs)
Delay on deenergisation K1
One-channel < 130 ms
Two channels 24 V DC: < 30 ms; AC: < 50 ms
Mechanical data
Enclosure material Polyamide PA 6.6
Dimensions ( W x H x D ) in mm 22,5 x 114,5 x 99
Mounting Click-fastening for DIN-Rail
Environmental data
Operating temperature range -25 °C ... +55 °C (UL +40 °C)
Air humidity Swap climate, 95 %, 0 ... +50 °C
Degree of protection, terminals IP 20 DIN VDE 0470 part 1
Degree of protection, enclosure IP 40 DIN VDE 0470 part 1
Shock resistance N.O./N.C. contacts 8g / 2g
EU Conformity
acc. to directive 2006/42/EG (Safety-of-Machinery-Directive)
acc. to directive 2014/30/EU (EMC-Directive)
Approvals
TÜV type tested
CUL US
Certifications
Tested in accordance with EN ISO 13849-1
Achieved level/category Performance Level e , Kat.4
MTTFd [years] 154 “high”
DC 99 % “high”
CCF achieved
Notes
With monitoring of the START-button.