Product Data
No. MPDUS0079EAB
INTRODUCTION
This system achieves high sensitivity and high quality by
using state-of-the-art digital technology in the T/R section,
which is the core of a diagnostic ultrasound system.
This system features advanced algorithms that run on cir-
cuits that incorporate the latest circuit technology, semicon-
ductor technology, and surface-mount technology.
This system is designed to support a full range of applica-
tions and can be used as a general purpose system or a spe-
cialized system, depending on the installed software.
USUR-AI900A,
Reference Signal kit This kit is used to display reference signals (ECG waveforms etc.).
USUR-AI900A/EL
USSE-AI900A,
Stress Echo kit Adds the cardiac stress examination function to the system.
USSE-AI900A/EL
USWT-AI900A,
2D Wall Motion Tracking kit Adds the cardiac wall motion analysis function to the system.
USWT-AI900A/EL
USEF-AI600A,
Auto EF Measurement kit Software to enable Ejection Fraction to be measured automatically.
USEF-AI600A /EL
Pencil Connector unit UIPC-AA550A This unit is used to add connectors for pencil transducers.
M-TEE hanger kit UAEH-AI900A TEE transducer hanger for the PET-512MA, PTE-512MC, and PET-512MD.
CV kit UACV-AA550A This kit consists of preset data suitable for cardiovascular examinations, a CV sticker, and a startup screen.
This kit is used to add the STC knob on the operating panel.
STC kit UIST-AI900A Use in combination with UIUB-AI900 is not possible.
*Note that this kit can not be instaled if the UIUB-AI900A.
USHI-AA550A,
CHI kit Adds the Contrast Imaging function to the system.
USHI-AA550A/EL
(*1) Not available in the USA. (*3) Some options are required in addition to UIFR-AA550A.
(*2) Only available in the USA.
2
MPDUS0079EAB
USLM-AI900A, Image processing technology that makes 3D/4D images of fetuses and anatomical structures appear
Luminance kit
USLM-AI900A/EL more realistic. The USMV-AI900A or Smart Sensor 3D kit is needed.
USOB-AI900A, Used for calculation of the volume by extracting the contours for regions with lower brightness in the 3D
Auto Volume Measurement kit
USOB-AI900A/EL Volume image acquired in 4D mode. Enables volume measurement, eg, antral follicle count.
USPF-AI900A,
3D printer format export kit This kit enables output of volume data for Smart 3D, Mecha4D and Smart Sensor 3D to 3D printers.
USPF-AI900A/EL
USEL-AA551A,
Elastography-FLR kit This kit enables Elastography (with FLR measurement) with linear and convex transducers. (*1)
USEL-AA551A/EL
USEL-AA550A,
Elastography kit The kit enables Elastography without FLR measurement. (*2)
USEL-AA550A/EL
USSW-AA550A,
Shear wave kit This kit allows tissue stiffness to be visualized by generating images that show shear wave propagation.
USSW-AA550A/EL
USFN-AA550A, CT/MRI/US volume data is loaded, and a CT/MRI/US planar image and an ultrasound image at the same
Smart Fusion kit
USFN-AA550A/EL position are displayed together. The UIFR-AA550A is required.
This kit is used to generate the magnetic field for acquiring positional information for transducers and
Magnetic Generator kit UIFR-AA550A needles in Smart Fusion, Smart Navigation, and Smart Sensor 3D modes. Sensor securing adaptors and
magnetic sensors are provided (one set for the PVT-375BT or PVT-375SC, and one set for the PVT-475BT).
This magnetic sensor is added for performing Smart Fusion, Smart Navigation, and Smart Sensor 3D using
Sensor kit for Fusion unit UIFR-A501A
multiple transducers. The UIFR-AA550A is required.
USFN-AI901A, Used for the Smart Fusion function. Performs automatic position matching between the ultrasound
Auto Registration kit
USFN-AI901A/EL volume data acquired in a previous exam and the real-time 2D ultrasound image.
(*1) Not available in the USA. (*3) Some options are required in addition to UIFR-AA550A.
(*2) Only available in the USA.
3
Unit Model name Remarks
TM
Position matching device for CT images (CIVCO omniTRAX ), including a magnetic sensor and 12 pieces
Auto Track CT kit UIOT-AI900A of omniTRAX.
* USFN-AA550A is required.
TM
Position matching device for MRI images (CIVCO omniTRAX ), including a magnetic sensor and 12 pieces
Auto Track MR kit UIOT-AI901A of omniTRAX.
* USFN-AA550A is required.
This pole cart allows the magnetic field generator included in the system main unit to be positioned
Fusion Pole Cart UZWT-A500A
independently.
Smart Navigation Sensor kit UISN-A500A This kit is used to mount a magnetic sensor to omniTRAX purchased by CIVCO.
USSS-AI900A, This function is used to display high-precision Smart 3D images by detecting the position of the
Smart Sensor 3D kit
USSS-AI900A/EL transducer based on positional information acquired using the magnetic sensor.
USMP-AI900A,
MicroPure™ kit This kit enables MicroPure, which supports visualization of small structures.
USMP-AI900A/EL
USPV-AI900A,
Panoramic View kit B/W images can be obtained with a wider field of view by moving the transducer in the lateral direction.
USPV-AI900A/EL
USRC-AI900A, This function is used to visualize images with fewer artifacts by cancelling multiple reflections from the
Multi-Reflection Canceller kit
USRC-AI900A/EL body.
Fetal Heart MPI Measurement USFH-AI600A, This kit enables Myocardial Performance Index (MPI). The MPI value can be calculated from the time
kit USFH-AI600A/EL change curve in TDI.
USZS-AI900A,
Measurement Z score kit This kit enables Z-score analysis for the measurement results.
USZS-AI900A/EL
OB kit UAOB-AI900A This kit consists of preset data suitable for OB examinations, an OB sticker, and a startup screen.
(*1) Not available in the USA. (*3) Some options are required in addition to UIFR-AA550A.
(*2) Only available in the USA.
4
MPDUS0079EAB
Rack for mounting a DVD recorder and a color printer on two levels.
UZRI-AI902A
(Not available with UZRI-AI900A)
Mounting kit for peripheral
unit
UZRI-AA550A Rack for mounting a B/W printer in the front or back (For UP-D711/AC or P95DW-DC)
Rack for mounting a color printer or a DVD recorder in addition to a B/W printer in the front. (not available
UZRI-AA551A
with other UZRI options).
Foot switch UZFS-004A Switch used for freezing, printing, and some other operations by foot.
Gel warmer UZGW-008A This unit warms the ultrasound gel to a suitable temperature.
Transducer cable hanger kit UZMK-AI900A Long hanger on which the transducer cable is hooked.
A basket to store transducer connectors is added to the side of the system main unit (one basket is
Transducer Holder kit UZBK-AI900A
provided in the standard configuration)
This kit used to establish connection to the DICOM network via wireless LAN. Complied with the
UIWL-A500A Radio Law of Japan and applicable laws and regulations of USA, EU member states, Iceland, Norway,
Liechtenstein, and Switzerland.
Wireless LAN kit
This kit enables connection to the DICOM network via wireless
UIWL-AI900A
LAN. (For Singapore, Malaysia, Saudi Arabia, Russia, Australia, and Turkey.)
EV/ER Transducer Holder kit UZPH-AI900A This kit is used to add a dedicated holder for endocavitary transducers.
Keyboard kit UIKB-AI900A This kit is used to add a hardware full keyboard for entering the patient ID and comments.
This kit adds a tablet terminal that communicates with the system main unit via wireless LAN to
allow viewing and easy operation of the examination screen. Complied with the Radio Law of Japan
2nd Console kit UITB-AI900A
and applicable laws and regulations of USA, EU member states, Iceland, Norway, Liechtenstein, and
Switzerland. UIWL-A500A is included.
DataBase for External USDB-AI900A, Function for setting up the patient database in the USB HDD in order to perform examinations.
HDD kit USDB-AI900A/EL *UZHI-AI900A is required.
Box with lock for installing the external HDD. HDD itself is not included.
Mounting kit for External HDD UZHI-AI900A
*USDB-AI900A is required.
ECG Cable Hanger kit UZMK-AI901A Hook used to hang the ECG cables on the front of the operating panel.
A battery kit to provide approximately 30 minutes of operation without being connected to a power out-
Battery unit UEBT-AA550A
let.
Track Ball kit UZTB-AI900A Newly designed (heavier) trackball to improved response to user and therefore workflow.
(*1) Not available in the USA. (*3) Some options are required in addition to UIFR-AA550A.
(*2) Only available in the USA.
5
Unit Model name Remarks
Tilt panel kit UITP-AA550A Kit for enabling tilting of the touch panel.
USHE-AI900A,
Online Help kit Kit for displaying the operation manual on the viewing monitor.
USHE-AI900A/EL
USPA-AI900A, A sequence of operations is registered, and each operation is executed by single switch operation. Not
Protocol Assistant kit
USPA-AI900A/EL necessary when USSE-AI900 is installed.
USRI-AI600A,
Reference Image kit Software to enable images from a previous examination to be displayed at the right of the screen.
USRI-AI600A/EL
UZKF-AI900A
(French)
UZKG-AI900A
(German)
UZKI-AI900A
(Italian)
UZKS-AI900A
(Spanish)
This kit is intended for changing the key tops of the full keyboard to support specific languages.
Local Language Key-Top kit
UZKD-AI900A
(Danish)
UZKN-AI900A
(Norwegian)
UZKW-AI900A
(Scandinavian)
UZKR-AI900A
(Russian)
(*1) Not available in the USA. (*3) Some options are required in addition to UIFR-AA550A.
(*2) Only available in the USA.
6
MPDUS0079EAB
Main unit A
CUS-AA450A
STC kit
UIST-AI900A Note: Not Available with Panel USB Port,
UIUB-AI900A.
TEE-Hanger
UAEH-AI900A
UAEH-AI901A
Foot Switch
UZFS-004A
A B
7
B C
Multi-refrection DataBase
Canceller kit for External HDD kit
USRC-AI900A USDB-AI900A
Mounting kit
Super Micro-vascular for External HDD kit
Imaging kit UZHI-AI900A
USMI-AI600A
Panel USB Port kit
Refference Image kit UIUB-AI900A Note: Not Available with STC kit,
UIST-AI900A.
USRI-AI600A
Online Help kit
Measurement Z score kit USHE-AI900A
USZS-AI900A
Buttery unit
OB kit UEBT-AA550A
UAOB-AI900A
Gel warmer
UZGW-008A
C D
8
MPDUS0079EAB
Mounting kit
for fusion sensor
UAFS-001A, UAFS-002A, UAFS-003A,
UAFS-004A, UAFS-005A, UAFS-006A,
UAFS-007A, UAFS-010A
(Note)
Smart Fusion kit (Note) Smart Sensor 3D kit
USFN-AA550A USSS-AI900A
9
TRANSDUCER OPTIONS/OPERATION MODES
Freq. Freq.Range Precision
Transducer name Range 2D ApliPureTM MicroPureTM *1 BEAM M CDI Power
(MHz) (MHz) Imaging
10
MPDUS0079EAB
PLT-308BTP
PLT-704SBT
PLT-705BT
PLT-705BTF
PLT-705BTH
PLT-1005BT
PLT-1202BT
PLT-1204BT
PET-508MA
PET-512MA
PET-512MC *5
PET-512MD *5
*4
PET-805LA
PC-20M
PC-50M
11
TRANSDUCER OPTIONS/OPERATION MODES
*1
*5 STIC Smart Sensor *1 Smart 2D
Transducer name STIC *5 Fusion *1 Remarks
Color 3D 3D*1 Navigation WMT
PSI-70BT
PST-25BT
PST-30BT
PST-50BT
PVT-350BTP *4
PVT-375BT
PVT-375SC *8
PVT-382BT
PVT-475BT *8
PVT-482BT *8
PVT-674BT
PVT-675MVL *2 *2 *5
*2 *2
PVT-675MVS *5
PVT-681MVL *5
PVT-712BT
PVT-745BTF
PVT-745BTH
PVT-745BTV
PVT-781VT
PVT-781VTE
Convex
PVL-715RST
Linear
PLT-308BTP *4
PLT-704SBT
PLT-705BT
PLT-705BTF
PLT-705BTH
PLT-1005BT
PLT-1202BT
PLT-1204BT
PET-508MA
PET-512MA *4
PET-512MC *5
PET-512MD *5
PET-805LA
PC-20M *6, *7
PC-50M *6, *7
12
MPDUS0079EAB
13
• Image Size • Flex-M
The displayed image size can be switched between Any desired plane can be set on the 2D-mode image and
small and large. the M-mode image for the set plane can be reconstructed.
• ApliPure™
– ApliPure Doppler (Spectrum Doppler)
This function reduces ultrasound wave interference with- • Doppler Mode
in tissues, which appear as speckle patterns or speckle – PWD (pulsed-wave Doppler)
noise on 2D images. – HPRF PWD (can be switched to HPRF mode)
– ApliPure+ – CWD (continuous-wave Doppler)
This function can display the boundaries between (USCW-AI900A is required.)
tissues more clearly and reduce speckle noise and acous- – Pencil CWD (pencil-type transducer)
tic shadows. (UIPC-AA550A and USCW-AI900A are required.)
• MicroPure (USMP-AI900A is required.) • Doppler Pulse Repetition Frequency (PRF)
– PWD: 0.3 kHz to 52.1 kHz
– Small structures can be extracted by performing
– CWD: 1.4 kHz to 52.1 kHz
filtering for 2D-mode images.
• Doppler Scan
– Visualization of very small calcifications and other
– 2D/D simultaneous scan
extremely small lesions can be improved.
– D only scan
• Precision Imaging
• Doppler Sampling Volume
– Precision+
The Doppler range gate width can be changed. (Minimum
· Structures in 2D-mode images can be displayed more
0.3 mm)
clearly and the background can be displayed more
• Doppler Sampling Shift
smoothly.
0 cm to the maximum depth
· Saturation in high-intensity regions of tissue structures
• Doppler Cursor Mode
is reduced, allowing the tissue structures to be dis-
Operation for the 2D live image is possible with the
played in a more natural manner.
Doppler sampling volume displayed in it.
• TSO (Tissue Specific Optimization) • Doppler Filter
– Reception focus compensation can be performed. The Doppler filter cutoff can be changed.
– Automatic reception focus compensation can be • Doppler Gain
performed. (Auto TSO) The display brightness for Doppler can be changed.
• BEAM (Biopsy Enhancement Auto Mode) • Doppler Quick Scan
– Display of the needle can be enhanced in the image. The Doppler scale and baseline shift can be adjusted auto-
– The enhancement level can be adjusted. matically.
• Doppler Frequency Analysis and Image Processing
M mode
– Method: FFT
• M Transmission Frequency
– No. of data items: 255 (maximum)
Multi frequency: 5 types (at maximum)
• Indication of Doppler Spectrum Direction
• M Sweep Speed
Reverse display of the velocity spectrum is possible.
The Sweep Speed can be changed in M mode.
• Doppler Baseline Shift (Zero Shift)
• M Gain
– The velocity baseline of Doppler images can be shifted.
M gain can be corrected for 2D gain. – The baseline shift setting can also be adjusted when
• M Image Processing Parameters images that were frozen are displayed.
– M dynamic range (can be changed even after the image • Doppler Audio
has been frozen). Stereo output (blood flow toward and away from the trans-
– M auto gain control ducer)
– M gamma (can be changed even after the image has • Doppler Map
been frozen). The brightness conversion table and the virtual color for
• M Map Doppler images can be set.
M image virtual color setting is possible. The setting can be • Display of Doppler Scale
changed even after the image has been frozen. 2 types (velocity, Doppler shift frequency)
• THI (Tissue Harmonic Imaging) • Doppler Focus
2D mode and THI mode are linked, and M images can be Automatically follows the sample position.
displayed in THI mode. • Doppler Angle Mark
– Pulse subtraction method This mark is displayed for measuring the angle between
– Filtering method the direction of the velocity and the direction of the ultra-
– Differential method sound beam.
• M Mark • Doppler Oblique Scan (PWD Steering)
– The M cursor can be displayed on 2D or C images. – Oblique scans are possible using a specific linear trans-
– The M cursor displayed position can be adjusted. ducer.
– Auto Invert function
14
MPDUS0079EAB
16
MPDUS0079EAB
• Elastography (USEL-AA551A or USEL-AA550A is required.) – ECG Sync Acquisition function can be used.
– Tissue stiffness can be visualized based on the changes – Shear wave measurement can be performed.
in velocity resulting from physical compression and • Smart Sensor 3D (USSS-AI900A, UIFR-AA550A, and UIFR-
decompression of the target region. AI501A are required.)
– FLR measurement can be performed to calculate the Generation of 3D images can be performed based on the
strain within the set ROI. (Not available in the USA.) positional information obtained using the magnetic sensor
• VI (Vascularity Index) attached to the transducer.
The number of pixels in the Power/ SMI image and within – The following functions can be used.
the ROI, the area of the Power/ SMI image and of the ROI, · Volume Color
and the ratio of the number of pixels in the Power/ SMI · Multi View
image to the number of pixels within the ROI can be dis- · Volume View
played for an image acquired in Power/ SMI mode. · Magic Cut
Available on all linear transducers. · CHI (USHI-AA550A is required.)
• Fusion (Smart Fusion) (USFN-AA550A etc. is required.) · Luminance (USLM-AI900A is required.)
Synchronization of ultrasound scanning with CT/MRI · Shear Wave (USSW-AA550A is required.)
image display adjusted according to the examination posi- · OmniView
tion determined using a magnetic sensor attached to the · ECG Sync Construction
transducer can be performed. · STL export (USPF-AI900A is required.)
– The following video modes can be selected. – The following measurements can be performed.
· 2D mode (B mode) · MPR
· Color Doppler · Multi Auto Volume Measurement (USOB-AI900A is
· PWD (pulsed-wave Doppler) required.)
· CWD (continuous-wave Doppler) (USCW-Al900A is • Smart 3D
required.) 3D image can be generated from the 2D image and any
· CHI (Contrast Harmonic Imaging) (USHI-AA550A is input volume shape.
required.) – The following functions can be used.
· Elastography (USEL-AA551A or USEL-AA550A is · Volume Color
required.) · Multi View
– The following image data can be referred to. · Volume View
· CT · Magic Cut
· MR · Omni View
· PET · CHI (USHI-AA550A is required.)
· 3D US (USSS-AI900A is required.) · Shear Wave (USSW-AA550A is required.)
– The following functions can be used. · STL export (USPF-AI900A is required.)
· Blend display • Reference (USRI-AI600A is required.)
· Segment display The ultrasound images of the current examination and the
· Multiplane display (Triple display) previously acquired image of the patient can be displayed
· Multivolume display (Quad display) simultaneously.
· 3D body mark display (Quad display) – The following video modes can be selected.
· Comparative display (Quad display) · 2D mode (B mode)
· Auto Registration (USFN-AI901A is required.) · Color Doppler
· Auto Track (UIOT-AI900A or UIOT-AI901A is required.) – The following image data can be referred to.
– The following measurements can be performed. · US image (still image)
· Basic measurement · Raw data acquired using CUS-AA450
· Cardiac measurement (for ultrasound live image) · CT
• Protocol Assistant (USPA-AI900A is required.) · MR
A series of operations (a protocol) that has been created · MG
for the intended examination can be executed automatically. · PET
Protocols can be created and edited. – The following measurement can be performed.
• Shear wave (USSW-AA550A is required.) Basic measurement
Images representing the speed of propagation of tissue
displacement (shear wave speed) can be visualized (shear
wave scan) by locally displacing tissues by transmitting a
burst wave with high acoustic pressure.
– The following Shear wave display modes are available.
· Speed: shear wave speed display (m/s)
· Elasticity: elasticity display (kPa)
· Propagation: propagation display
17
Display-Related Features · DVD/CD write status
• Display Method · Network use status
– Images on the main unit: 60 Hz non-interlaced display · PACS use status
– Images from external · Used space on HDD
playback devices: 60 Hz non-interlaced display · Saving dynamic/still image
• Monitor Display/Character Display · DICOM printer status/peripheral device status
– ID area · USB flash drive status display
· Patient ID – Multifunction display area
· Patient name Assignment statuses for trackball and surrounding
· Hospital name switches and dials
· Date: Selected from among the formats • Annotation
shown below. – Manual input using the keyboard is possible.
YYYY/MM/DD – Auto annotation (previously specified text) is possible.
MM/DD/YYYY • Pictograms
DD/MM/YYYY Body icons and transducer mark
YYYY: Western calendar year • Biopsy Guide Mark
MM: Month Biopsy guide mark display is possible.
DD: Day • Touch Panel (TCS: Touch Command Screen)
· Time: Selected from among the formats – 12.1-inch LCD monitor: SXGA (1280 x 800)
shown below. – The touch panel tilt angle can be changed by 15°. (UITP-
hh:mm:ss: AM (PM) AA550A is required.)
hh:mm:ss: 24-hour representation • Language
hh: Hour The following languages are supported for the display of
mm: Minute some screens and keyboard entry.
ss: Second
· VIDEO mark, VCR counter
· Age
· Sex
Supported Screen Input by software Input by hardware
· Heart rate display (heart-shaped mark/heart rate)
· Name of the Imaging Preset language display keyboard keyboard*
· Name of the operator English
· Gestational age
– Acoustic power display area
English (UK)
· Acoustic power value (%) (same as"English") (same as"English")
· TI value
German
– Auto data
Frame rate French
Acoustic power index = MI indication Italian
Transducer frequency
Depth Spanish
Dynamic range Danish
GAIN
Dutch
CDI filter
PRF Norwegian
Doppler filter Swedish
Doppler angle
Doppler gate size Finnish
– Thumbnail area Portuguese
· Image data acquired during the current examination is
Icelandic
displayed.
· Information from a previous examination of the patient Russian
currently being examined is displayed. Japanese
– Information message display area
Chinese
An operation guide and other messages are displayed.
– Status area : Applicable : Not applicable
The following system statuses can be displayed. *: UIKB-AI900A is required.
· Battery capacity
18
MPDUS0079EAB
22
MPDUS0079EAB
MASS
Model name Name of component Mass [kg] (lb) Model name Name of component Mass [kg] (lb)
System main unit USPV-AI900A Panoramic View kit 0.1 (0.2)
CUS-AA450 Aplio a450 95 (209.4) USRC-AI900A Multi-reflection Canceller kit 0.1 (0.2)
Options/Accessories for main unit USFH-AI600A Fetal Heart MPI Measurement kit 0.1 (0.2)
USCW-AI900A CW kit 0.1 (0.2) USZS-AI900A Measurement Z score kit 0.1 (0.2)
USUR-AI900A Reference Signal kit 0.1 (0.2) UAOB-Al900A OB kit 0.1 (0.2)
UJUR-AI900A Reference signal cable 0.3 (0.7) UZRI-AI900A Mounting kit for peripheral unit 1.1 (2.4)
UJUR-AI901A Reference signal cable 0.1 (0.2) UZRI-AI902A Mounting kit for peripheral unit 3.1 (6.8)
UJUR-AI902A Reference signal sensor unit 0.4 (0.9) UZRI-AA550A Mounting kit for peripheral unit 2.8 (6.2)
USSE-AI900A Stress Echo kit 0.1 (0.2) UZRI-AA551A Mounting kit for peripheral unit 4.5 (9.9)
USWT-AI900A 2D Wall Motion Tracking kit 0.1 (0.2) UZFS-004A Footswitch 0.6 (1.3)
USEF-AI600A Auto EF Measurement kit 0.1 (0.2) UZGW-008A Gel warmer 1 (2.2)
UIPC-AA550A Pencil Connector unit 0.3 (0.7) UZMK-AI900A Transducer cable hanger kit 0.9 (2.0)
UAEH-AI900A M-TEE hanger kit 1.5 (3.3) UZBK-AI900A Transducer Holder kit 0.3 (0.7)
UAEH-AI901A TEE hanger kit 1.2 (2.6) UIWL-A500A Wireless LAN kit 0.5 (1.1)
UACV-AA550A CV kit 1.0 (2.2) UIWL-AI900A Wireless LAN kit 0.5 (1.1)
UIST-AI900A STC kit 0.1 (0.2) UZPH-AI900A EV/ER Transducer Holder kit 1.6 (3.5)
USPF-AI900A 3D printer format export kit 0.1 (0.2) UIKB-AI900A Keyboard kit 1.1 (2.4)
USHI-AA550A CHI kit 0.1 (0.2) UITB-AI900A 2nd Console kit 1.1 (2.4)
USMV-AI900A 4D kit 0.1 (0.2) UZHI-AI900A Mounting kit for External HDD kit 1.0 (2.2)
USLM-AI900A Luminance kit 0.1 (0.2) USDB-AI900A DataBase for External HDD kit 0.1 (0.2)
USOB-AI900A Auto Volume Measurement kit 0.1 (0.2) UZMK-AI901A ECG Cable Hanger kit 0.1 (0.2)
USEL-AA551A Elastography-FLR kit 0.1 (0.2) UIUB-AI900A Panel USB Port kit 0.1 (0.2)
USEL-AA550A Elastography kit 0.1 (0.2) UEBT-AA550A Battery unit 13 (28.7)
USSW-AA550A Shear wave kit 0.1 (0.2) UZTB-Al900A Track Ball kit 0.2 (0.4)
USFN-AA550A Smart Fusion kit 0.1 (0.2) UITP-AA550A Tilt panel kit 1.5 (3.3)
UIFR-AA550A Magnetic Generator kit 15.0 (33.0) USHE-AI900A Online Help kit 0.1 (0.2)
UIFR-A501A Sensor kit for Fusion unit 0.1 (0.2) USPA-AI900A Protocol Assistant kit 0.1 (0.2)
USFN-AI901A Auto Registration kit 0.1 (0.2) USRI-AI600A Reference Imaging kit 0.1 (0.2)
UIOT-AI900A Auto Track CT kit 0.4 (0.9) UZKF-AI900A Local Language Key-Top kit 0.5 (1.1)
UIOT-AI901A Auto Track MR kit 0.6 (1.3) UZKG-AI900A Local Language Key-Top kit 0.5 (1.1)
UZWT-A500A Fusion Pole Cart 26 (57.3) UZKI-AI900A Local Language Key-Top kit 0.5 (1.1)
UAFS-001A Mounting kit for fusion sensor 0.1 (0.2) UZKS-AI900A Local Language Key-Top kit 0.5 (1.1)
UAFS-002A Mounting kit for fusion sensor 0.1 (0.2) UZKD-AI900A Local Language Key-Top kit 0.5 (1.1)
UAFS-003A Mounting kit for fusion sensor 0.1 (0.2) UZKN-AI900A Local Language Key-Top kit 0.5 (1.1)
UAFS-004A Mounting kit for fusion sensor 0.1 (0.2) UZKW-AI900A Local Language Key-Top kit 0.5 (1.1)
UAFS-005A Mounting kit for fusion sensor 0.1 (0.2) UZKR-AI900A Local Language Key-Top kit 0.5 (1.1)
UAFS-006A Mounting kit for fusion sensor 0.1 (0.2) UP-D711MD/AC B/W printer 1.0(2.2)
UAFS-007A Mounting kit for fusion sensor 0.1 (0.2) UP-D898MD B/W printer 2.6 (5.7)
UAFS-010A Mounting kit for fusion sensor 0.1 (0.2) P95DW B/W printer 2.6 (5.7)
UISN-A500A Smart Navigation Sensor kit 1.0 (2.2) P95DW-DC B/W printer 1.6 (3.5)
Superb Micro Vascular Imaging UP-D25MD Color printer 5.5 (12.1)
USMI-AI600A 0.1 (0.2)
kit
CP30DW Color printer 7.3 (16.1)
USSS-AI900A Smart Sensor 3D kit 0.1 (0.2)
HVO-550MD/
USMP-AI900A MicroPure kit 0.1 (0.2) DVD video recorder 3.2 (7.1)
FDH
23
Model name Name of component Mass [kg] (lb) Model name Name of component Mass [kg] (lb)
Transducers PVT-781VTE Endocavitary transducer 0.97 (2.1)
PSI-70BT Phased array transducer 0.65 (1.4) PVL-715RST Endocavitary transducer 1.04 (2.3)
PST-25BT Phased array transducer 0.8 (1.8) PLT-308BTP Linear array biopsy transducer 0.8 (1.8)
PST-30BT Phased array transducer 0.8 (1.8) PLT-704SBT Linear array transducer 0.9 (2.0)
PST-50BT Phased array transducer 0.8 (1.8) PLT-705BT Linear array transducer 0.85 (1.9)
PVT-350BTP Convex array biopsy transducer 0.95 (2.1) PLT-705BTF Linear array transducer 0.78 (1.7)
PVT-375BT Convex array transducer 0.95 (2.1) PLT-705BTH Linear array transducer 0.78 (1.7)
PVT-375SC Convex array transducer 0.95 (2.1) PLT-1005BT Linear array transducer 0.85 (1.9)
PVT-382BT Convex array transducer 0.8 (1.8) PLT-1202BT Linear array transducer 0.75 (1.7)
PVT-475BT Convex array transducer 0.8 (1.8) PLT-1204BT Linear array transducer 0.85 (1.9)
PVT-482BT Convex array transducer 0.75 (1.7) Multi-plane transesophageal
PET-508MA 1.2 (2.6)
PVT-674BT Convex array transducer 0.9 (2.0) transducer
PVT-675MVL Convex array transducer 1.1 (2.4) Multi-plane transesophageal
PET-512MA 1.32 (2.9)
transducer
PVT-675MVS Convex array transducer 1.05 (2.3)
Multi-plane transesophageal
PVT-681MVL Endocavitary transducer 1.15 (2.5) PET-512MC 1.6 (3.5)
transducer
PVT-712BT Convex array transducer 0.8 (1.8)
Multi-plane transesophageal
PVT-745BTF Convex array transducer 0.8 (1.8) PET-512MD 1.5 (3.3)
transducer
PVT-745BTH Convex array transducer 0.8 (1.8) PET-805LA Linear array transducer 1.17 (2.6)
PVT-745BTV Convex array transducer 0.78 (1.7) PC-20M CW Doppler pencil transducer 0.085 (0.2)
PVT-781VT Endocavitary transducer 0.97 (2.1) PC-50M CW Doppler pencil transducer 0.08 (0.2)
https://global.medical.canon
©Canon Medical Systems Corporation 2018. All rights reserved.
Design and specifications are subject to change without notice.
Model number: CUS-AA450 MPDUS0079EAB V1.3 2018-05 CMSC/Produced in Japan
Canon Medical Systems Corporation meets internationally recognized standards for Quality Management System ISO 9001, ISO 13485.
Canon Medical Systems Corporation meets the Environmental Management System standard ISO 14001.
Aplio, Dynamic Flow, ApliPure, MicroPure, Pulse Subtraction, VolPure, TwinView and Made for Life are trademarks of Canon Medical Systems
Corporation.
Windows is a registered trademark of Microsoft Corporation in the United States and / or other countries.
omniTRAX is a trademark of CIVCO Medical Solutions.