MOVITRANS® spot –
contactless
energy transfer system
POSSIBLE USES / TYPICAL APPLICATIONS
ADVANTAGES AT A GLANCE
Stationary components 4 TIS30A installation plate
Nominal voltage: up to DC 60 V
(system frequency 50 kHz): Installation of MOVITRANS® spot with TFS50A Suitable for use from +5 °C to +40 °C.
possible without ground penetration. The surfaces
Nominal voltage: up to DC 360 V
1 TES30 decentralized supply unit can be assembled and disassembled quickly by
Suitable for outdoor use from
Power: 8 kW connecting the installation plates with groove and
-25 °C to +55 °C.
Line voltage V: 380 V – 500 V ± 10% tongue using a jigsaw system. This increases the
SAFS (Safe AC Field Stop) function via binary inputs. flexibility and adaptability of the factory.
6 Energy storage bundle
Energy storage or peak load buffering through
New: With the SAFS function, the charging
Mobile components:
double-layer capacitors. Fast and direct energy
point can be safely switched off, for example, if
intake and energy release. High number of
there is no vehicle above the point. The charging 5 TDM80E pick-up
charging cycles possible.
point is thus safely free of a magnetic field.
Nominal power: up to 11 kW for 4 minutes
Engineering via EtherCAT®/SBusPLUS
2 TCS50 compensation box
compensates for the supply line and inductance
of the field plate
1
6
MOVITRANS® spot is made up of both stationary and
mobile system components that can be quickly and
easily integrated into existing automation systems. The
nominal air gap between the point-based charging plate 4
and the pick-up is 20 mm. This makes it possible to 5
achieve high transmission power even with a high
3
2269 2169 / 0722
ground clearance.