OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

IMPORTANT SETTING CURRENT TIME


Don't connect an appliance where the load exceeds 13 Amp. If cleaning of the timer is required, please cut off mains power and 1. Press CLOCK button and hold, simultaneously press WEEK button until the actual day is displayed. Continue by pressing HOUR or
wipe timer with a dry cloth. DO NOT IMMERSE TIMER IN WATER OR ANY OTHER LIQUID. MIN button until the current hour or minute is displayed. When setting, the buttons WEEK, HOUR or MIN can be held down
for rapid forward counting.
2. Release both buttons. The week and time will be set.
Wiring Instructions 3. To reset incorrect time, repeat above steps.

1. SWITCH OFF AT MAINS.


2. Remove cover. SETTING PROGRAMS
3. Cut cable to suit time switch
position and bare ends of cable, TIP: When verifying your programs ensure that the settings do not overlap, especially when using the block option. If there are program settings
connecting as shown right diagram. overlapping, the timer ON or OFF will be executed according to program time, not by program number. Program OFF has the priority over program ON.
4. Replace cover,tighten screw. 1. Press TIMER button and release. LCD shows ON_1. The first ON setting can be made now.
2. Press WEEK button to set the day or block of days. Set the time by pressing HOUR and MIN button.
3. Press TIMER button again to finish the first ON setting and enter into the first OFF setting. LCD shows OFF_1. By repeating 2 to make the first OFF setting.
4. Press TIMER button again to finish the first OFF setting and enter into the 2nd ON setting. Repeat 2 and 3 to
program remaining settings. Press TIMER button and hold for 2 seconds to enter fast advance.
KEYB0ARD DEFINITION 5. After completing settings, press CLOCK button. The timer is ready to operate.
EXAMPLE: Timer ON at 17:15 and OFF at 22:30 everyday
a. MASTER CLEAR: Clear all data in memory including current time and all programs. a. Press TIMER once and release. LCD displays ON_1
b. RANDOM: Set or cancel random function. b. Press WEEK till LCD displays "MO,TU,WE,TH,FR,SA,SU"
c. CLOCK: Set current time combined with buttons WEEK, HOUR, MIN. Select 12 or 24 hour mode combined with button TIMER. Activate c. Press HOUR till LCD displays 5:00PM or 17:00
summertime function combined with button ON/AUTO/OFF. d. Press MIN till LCD displays 5:15PM or 17:15
d. TIMER: Set programs combined with buttons WEEK, HOUR, MIN. Select 12 or 24 hour mode combined with button CLOCK. e. Press TIMER again and release. LCD displays OFF_1
e. ON/AUTO/OFF: Select operating modes of timer. f. Repeat the above b, c and d till LCD displays "MO,TU,WE,TH,FR,SA,SU" 10:30PM or 22:30

GENERAL FEATURES MANUAL ON/AUTO/MANUAL OFF SETTING


1. 10 ON/OFF programs with 1 minute step. Operating modes can’t be changed during program settings.
2. Output LED indicator. 1. Press ON/AUTO/OFF button to revert the three modes in turn.
3. Display with second. 2. The programs can only be executed in AUTO mode. When AUTO is selected, the timer operates as the programs.
4. MANUAL ON/AUTO/MANUAL OFF selectable. In MANUAL ON or MANUAL OFF mode all programs are ignored and the timer doesn't operate. When MANUAL ON
5. Random function with a random advance of 10-31minutes between 6:00 PM and 6:00 AM. mode is selected, power output is always ON. When MANUAL OFF mode is selected, power output is permanently off.
6. 12/24 hour mode selectable. 3. When the mode is turned from MANUAL ON to AUTO, the timer will keep the setting of MANUAL ON until to the next timer setting.
7. Summer time function available.
8. 16 combinations of day or blocks of days available as follows:
Mo RANDOM FUNCTION
Tu
We 1. Press RANDOM button. LCD displays R(RANDOM). RANDOM function is activated.
Th 2. When this function is ON, the settings will be executed with a random advance of 10-31 minutes between 6:00 PM and 6:00AM.
Fr 3. Press the RANDOM button again to cancel this function. Random function can’t be set during program settings.
Sa 4. The RANDOM function can only be executed in AUTO mode between 6:00PM and 6:00AM.
Su
Mo, Tu, We, Th, Fr, Sa, Su SPECIFICATIONS
Mo, Tu, We, Th, Fr Voltage: 250VAC, 50Hz 12/24 HOUR MODE
Sa, Su Max Load: 13A, 3200W
Mo, Tu, We, Th, Fr, Sa Press CLOCK and TIMER simultaneously to turn the time display
Mo, We, Fr Min. Setting Time: 1 Minute between 12 and 24 hour mode.
‫ޕ‬ ‫ޕ‬
Tu, Th, Sa Operating temperature: -10 C to +40 C
Mo, Tu, We
Th, Fr, Sa
Accuracy: +/- 1 minute per month
SUMMERTIME FUNCTION
Battery backup: NiMH 1.2V > 100hours
Mo, We, Fr, Su
1. Press CLOCK and ON/AUTO/OFF simultaneously. LCD shows S(Summer time). Clock advances 1 hour.
2. To revert to winter setting, press the two buttons again. Clock moves backward 1 hour. S disappears in LCD.
INITIAL OPERATION
1. Connect the timer as wiring instructions and turn the power on. Leave for approximately 14 hours to charge the Memory Back-up battery.
2. Clear all current information by pressing MASTER CLEAR button with a sharp object such as a pen or pencil after charging.
3. The timer is now ready to be set up for use.