Nothing Special   »   [go: up one dir, main page]

Sono40 Data Sheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 22

Data sheet

SonoMeter 40
Energy Meters
Description Features
• Available in nominal flow rates qp 0.6, 1.5, 2.5,
3.5, 6.0, 10.0, 15.0, 25.0, 40.0 and 60 m3/h
• Triple communication with M-Bus, wMBus
onboard + 1 additional communication module
slot
• Housings with thread (G3/4 to G2) or flange
(DN 20 to DN 100) connections
• MID approval for ultrasonic energy meter with
dynamic range of 1:100 (qi:qp) in class 2
• Optional MID approved dynamic range of 1:250
in class 2
• Temperature range 0 - 180 °C
• Nominal pressure PN25 bar as standard
• Calculator with IP65 protection class as
standard (IP68 on special request)
• Flow sensor with IP68 protection class as
standard
• Return or supply pipe installation, for vertical or
horizontal mounting
• Battery lifetime for at least 15+1 years
The Danfoss SonoMeter 40 is a range of • Low pressure loss, insensitive to dirt
ultrasonic, compact energy meters intended for • No calming sections needed before or after the
measuring energy consumption in heating and flow sensor (DN 15-DN 50)
cooling applications for billing purposes. The • For DN 65 to DN 100 calming sections are
meters are designed for remote meter read-out needed (5 x DN on inlet and 3 × DN on outlet of
(AMR). flow sensor)
• Remote reading via M-Bus, radio OMS 868 MHz,
SonoMeter 40 energy meters consist of RS 485 Modbus, BACnet, LoRA-WAN, pulse
an ultrasonic flow sensor, a pair of Pt500 output or optical interface
temperature sensors and a calculator • Two pulse inputs or outputs (always included,
with integrated circuits for temperature optionally with pre installed cable)
measurement, flow calculation and energy
calculation.

© Danfoss | Energy Meters | 2022.03 AI384640298387en-010103 | 1


Data sheet SonoMeter 40

Technical specifications Complete energy meter


Application Heating or Bifunctional (combined heating and cooling)
Medium Water quality with pH 7 to 9.5 VDI 2035, VdTÜV TCh 1466
Flow: 1 sec.
Measuring cycle Energy: 1 sec.
Temperature: 10 sec.
ΔΘ: 3 - 175K
Approved meteorological range Θ: 0 - 180 °C
Θq: 0.1 - 130 °C
ΔΘ: 0.2 - 180K
Temp. limits (energy calculation)
Θ: 0 - 180 °C
Ambient operating temperature Class C: 5 - 55 °C indoor installation, condensing, humidity max. 93%.
Ambient storage temperature temperature: -25 – +35 °C, humidity: max. 60%.
Mechanical environment Class M1
Electromagnetic environment Class E2

Calculator
IP [EN60529] 65 (68 on special request)
Voltage 3.6V DC
Battery Supply Battery type and size 2x Lithium Battery, AA-size
Battery life time 15+1 years (including AMR communication)
12 V - 36 V AC
Voltage 12 V - 42 V DC
Galvanically isolated
Power consumption not more than 20 mA
Mains supply 24 V AC/DC Alternating current voltage frequency 50/60 Hz
(internal module) Internal backup battery: 1x AA-size
Service life not less than 15 years (without data reading via
Backup supply
a digital or wireless interface) - for powering of the meter,
when the external power supply is turned off.
Mains supply cable 2 wire copper cable with a diameter of 2 × 0.25 mm²
230 VAC +10% -15%
Voltage to 24VAC transformer for connection to mains power
supply 24 AC/DC module.
Power consumption not more than 5 mA
Mains supply 230 V AC Alternating current voltage frequency 50/60 Hz
(external transformer) Internal backup battery: 1x AA-size
Service life not less than 15 years (without data reading via
Backup supply
a digital or wireless interface) - for powering of the meter,
when the external power supply is turned off.
Mains supply cable 2 wire copper cable with a diameter of 2 × 0.25 mm²
85 x 35 mm LCD display with 8 digits (11.5 mm high main characters)
Display
Menu guide and info panel
Display Units MWh - kWh - GJ - Gcal - °C - m3 - m3/h
Display Values Energy - volume - flow rate - power - temperatures
Optical interface Always included According to EN61107 (IEC1107)
1. M
 -Bus according to EN13757-3, supports 300, 2400,
To be specified when ordering the
Communication 4800, 9600 baud. Delivered with 1,5 m cable.
meter. Both options can be selected.
2. wM-Bus 868 MHz (S1, T1 OMS)
1. Wired M-Bus
Delivered from factory or later
Additional 2. Modbus RTU
upgrade. One option from the list is
communication 3. BACnet MS/TP
possible.
4. LoRaWAN

2 | AI384640298387en-010103 © Danfoss | Energy Meters | 2022.03


Data sheet SonoMeter 40

Technical specifications
(continuous)

Flow sensor
Diameter DN 15 DN 20 DN 15 DN 20 DN 15 DN 20 DN 20 DN 25 DN 25 DN 40 DN 50 DN 65 DN 80 DN 100
Nominal flow qp (m3/h) 0.6 1.0 1.5 2.5 3.5 6 10 15 25 40 60
Max flow qs (m3/h) 1.2 2 3 5 7 12 20 30 50 80 120
Minimum flow (1:100) qi (m3/h) 0.006 0.01 0.015 0.025 0.035 0.06 0.1 0.15 0.25 0.4 0.6
Cut off flow qc (m3/h) 0.003 0.005 0.003 0.005 0.005 0.007 0.012 0.02 0.03 0.05 0.08 0.12
Overflow qss (m3/h) 1.44 2.4 3.6 6 8.4 14.4 24 36 60 96 144
Pressure drop at qp (mbar) 70 9 113 25 171 58 72 94 198 90 100 180 120 200 180 180
Kvs values 2.27 6.32 2.97 6.32 3.63 6.23 5.59 8.15 5.62 11.67 18.97 23.57 43.3 55.9 94.3 141.4
Connection G¾B G1B FL G¾B G1B FL G¾B G1B FL G1B G1B FL G1B G1¼B G1¼B G2B FL FL FL FL FL
Overall length (mm) 110 190 110 190 110 165 190 130 190 130 260 260 300 270 300 300 360
Material of flow sensor CW617N CC770S
Pressure PN (bar) 25 bar
IP [EN60529] IP68
Temperature media (°C) Θq: 0.1 - 130 °C
Cable length 1.2 m, 2.5 m or 5 m
Any position; DN 15 - DN 50: No calming sections needed
Mounting
DN 65 - DN 100: calming sections are needed (5 x DN on inlet and 3 x DN on outlet)

Temperature sensor
Type Pt500, 2 wire, according to EN1434, EN60751
Ø5.2 mm / IP65
Size / IP
Ø6 mm / IP67
Cable length 1.5 m, 3 m, 5 m or 10 m
Accuracy Class B (EN60751)
Approved temp. range EN60751 Θ: 0 - 150 °C
Difference temp. EN60751 ΔΘ: 3 - 150 K
Pressure 25 bar
Mounting without pockets for sizes G3/4 and G1 only

Communication interfaces Optical interface


Optical interface is integrated into the front
panel of the calculator. It is designed for data
reading via M-bus protocol and parameterization
of the meter using SonoMeter 40 UserConfig
software and optical head OG-1-USB.
The optical interface is activated by pressing
the control button and shuts automatically off
5 minutes after the last pressing button or after
completing data transmission via interface.

Wired M-Bus interface


- M-Bus protocol according to EN13757-3 - Default M-Bus telegram includes below
standard information’s:
- 2 wire with polarity reversal protection • Date and time
- Galvanic insulation • Date and time of error starting
- Current drawn: one M-Bus load (1.52mA) • Error code
- Primary or secondary addressing supported • Battery operation time
- Primary M-Bus address (M-Bus integrated) last • Working time without error
2 digits of a serial number; if “00” the primary • Energy for heating
address is 100. • (Energy for cooling)
- Primary M-Bus address (Additional M-Bus • (Energy of tariff 1)
module) Address “2”. • (Energy of tariff 2)
- Configurable baud rate • Volume
300/1200/2400/4800/9600, factory default • Pulse input 1
2400 baud rate. • Pulse input 2
- Battery lifetime min 15+1 years (2 x AA cell) • Power
- Battery supply communication is limited on • Flow rate
every 15 min at 2400 baud rate or faster, 70 • Temperature 1
energy meters on bus • Temperature 2
- Fastest reading interval at mains supply: no • Temperature difference
limits • Serial number

© Danfoss | Energy Meters | 2022.03 AI384640298387en-010103 | 3


Data sheet SonoMeter 40

Communication interfaces Wireless M-Bus (OMS) interface, 868.95 MHz


(continuous) - Wireless M-Bus protocol according to EN13757-4
- OMS (open metering system) compatible, compliant to OMS 4.0.2
- T1 mode (unidirectional)
- sending interval every 90 seconds
(suitable for ‘walk by’ readings)
- battery lifetime min 15+1 years (2 x AA cell)
- default wireless M-Bus telegram includes below information’s:
• Energy for heating
• Time
• Volume
• Energy for cooling
• Pulse in 1
• Pulse in 2
• Power
• Flow
Wireless M-Bus telegram parameter list and sending frequency is configurable!

Modbus RTU, RS485 module


Connectors 90 (noninverting, +) and 91 (inverting, -)
Baud rate 1200, 2400, 4800, 9600 (default), 38400, 56000, 57600, 115200 bps
8E1 (8 data bits, even parity bit, 1 stop bit) – default
Data format 8O1 (8 data bits, odd parity bit, 1 stop bit)
8N2 (8 data bits, no parity bit, 2 stop bits)
Polarity independent connection for power supply – connectors 60 and 61
Voltage 12-24 V AC/DC
Power supply
Maximum power consumption 2 W max.
Typical supply current 50 mA

BACnet MS/TP, RS485 module


BACnet MS/TP protocol and a serial interface for communication with external devices.
Connectors 90 (noninverting, +) and 91 (inverting, -)
Baud rate 9600, 19200, 38400 (default), 57600, 76800, 115200 bps
Data format 8E1 (8 data bits, even parity bit, 1 stop bit)
Polarity independent connection for power supply – connectors 60 and 61
Voltage 12-24 V AC/DC
Power supply
Maximum power consumption 2 W max.
Typical supply current 50 mA

LoRaWAN, 868 module


Transmitting scenarios:
• Heating: Energy and volume + 4 historical values.
• Heating and Cooling: Heating Energy, Cooling energy + Volume + 2 Historical values.
Pulse inputs
Number of pulse inputs 2 or no (to be specified when ordering)
indicated units m3
pulse value programmable
input pulse types IB according to LST EN1434-2
maximum permissible frequency 3 Hz
maximum permissible voltage 3.6 V
condition of maintenance of high level 3.6 V through 3.3 MΩ resistor

For versions with not openable enclosure (IP68), when meter is ordered with the pulse inputs, a
permanently connected 1,5 m cable is fitted in the meter for connecting the pulse inputs.
Pulse outputs
Number of pulse outputs 2 or no (to be specified when ordering)
Class OB in operating mode (OD in test mode)
Type open collector
Permissible current up to 20 mA
Voltage up to 24 V
Pulse duration 125 ms in operating mode (1.2 ms in test mode)

4 | AI384640298387en-010103 © Danfoss | Energy Meters | 2022.03


Data sheet SonoMeter 40

Communication interfaces Pulse value in the operating mode:


(continuous) - when the output is configured for energy, the value of its pulses can be selected from the list
Energy measurement units Possible values for the energy pulse *
„kWh“ or „MWh“ 0,00001; 0,0001; 0,001; 0,01; 0,1; 1; 10; 100; 1000; 10000 MWh/pulse
„GJ“ 0,0001; 0,001; 0,01; 0,1; 1; 10; 100; 1000; 10000 GJ/pulse
„Gcal“ 0,0001; 0,001; 0,01; 0,1; 1; 10; 100; 1000 Gcal/pulse
* length of values list depends of permanent flow rate and LCD energy value comma position

- when the output is configured for water quantity, the value of its pulses can be selected from
the list:
0,001; 0,01; 0,1; 1; 10 m³/pulse
For versions with not openable enclosure (IP68), when meter is ordered with the pulse outputs, a
permanently connected 1,5 m cable is fitted in the meter for connecting the pulse outputs.

Data logger Following hourly, daily and monthly parameter values are recorded in energy meter memory (can be
configured by SonoMeter 40 UserConfig software):
1............. Integrated heating energy
2............. Integrated cooling energy
3............. Integrated energy of tariff 1
4............. Integrated energy of tariff 2
5............. Integrated volume of liquid
6............. Integrated pulse value in pulse input 1
7............. Integrated pulse value in pulse input 2
8............. Maximum thermal power value for heating and date
9............. Maximum thermal power value for cooling and date
10.......... Maximum flow rate value and date
11........... Maximum value of flow temperature of heat conveying liquid and date
12........... Maximum value of return temperature of heat conveying liquid and date
13.......... Minimum value of flow temperature of heat conveying liquid and date
14.......... Minimum value of return temperature of heat conveying liquid and date
15.......... Minimum value of temperature difference and date
16.......... Average value of flow temperature of heat conveying liquid
17........... Average value of return temperature of heat conveying liquid
18.......... Operating time without an error of thermal energy calculation
19.......... Total error code
20.......... Time when the flow rate exceeded 1.2 qs
21.......... Time when the flow rate was less than qi

Data logger capacity


• up to 1480 h - for hourly records
• up to 1130 days - for daily records
• up to 36 last months - for monthly records
• Storage time of measured integrated parameters even if device is disconnected from
power supply: not less than 15 years
All data from archive can be read by means of the remote reading. In addition, data logger records of
monthly parameters can be seen on the display.

Bifunctional meters When the cooling energy tariff function is activated, in case of a negative temperature differential,
energy will be accumulated in the additional tariff register Q . In this case, energy values are
calculated according to the following formulas:
– when the flow sensor is in the supply line
when Θ1 > Θ2: Q = V · ρ1 · (hΤ1-hΤ2), Q  = 0
when Θ1 < Θ2: Q  = V · ρ1 · (hΤ2-hΤ1), Q = 0
– when the flow sensor is in the return line
when Θ1 > Θ2: Q = V · ρ2 · (hΤ1-hΤ2), Q  = 0
when Θ1 < Θ2: Q  = V · ρ2 · (hΤ2-hΤ1), Q = 0

© Danfoss | Energy Meters | 2022.03 AI384640298387en-010103 | 5


Data sheet SonoMeter 40

Application drawings

Flow direction

Return pipe installation

Flow direction

Supply pipe installation

Accuracy

5
4
3
2
Error [%]

1
0
-1
-2
Key
-3
EN1434 class 2
-4
typical accuracy
-5
qi qp qs

Flow measurment accuracy

6 | AI384640298387en-010103 © Danfoss | Energy Meters | 2022.03


Data sheet SonoMeter 40

Pressure loss

Menu structure

INT 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9
Integral parameters

Long press
BIL 2.1 2.2 2.3 2.4 2.5 2.6.1 2.7.1 2xx 2.15.1 Shift down
Statistical data

Short press
INF 3.1 3.2 3.3 3.4 3.5 3.6.1 3.7 3x 3.15 Shift to the right
Informative parameters

© Danfoss | Energy Meters | 2022.03 AI384640298387en-010103 | 7


Data sheet SonoMeter 40

Mounting

Pipe position: Rotation in pipe axis:


No limitations but avoid positions where air can Flow sensor should be angled in 45 to 315° to
be collected. avoid air collection in flow sensor.

5 x DN 3 x DN

flow

Inlet/outlet conditions (only for DN 65 - DN 100)


In order to maximize accuracy, it is necessary to have straight inlet and outlet flow conditions before
and after the flow sensor: 5 × DN on inlet and 3 × DN on outlet of flow sensor.

8 | AI384640298387en-010103 © Danfoss | Energy Meters | 2022.03


Data sheet SonoMeter 40

Dimensions
Calculator

Flow sensor qp= 0.6/1.0/1.5 m³/h


L=110 mm (L=165 mm);
connection type: thread G3/4”

Flow sensor qp= 1.5/2.5 m³/h


L=130 mm
connection type: thread G1“

© Danfoss | Energy Meters | 2022.03 AI384640298387en-010103 | 9


Data sheet SonoMeter 40

Dimensions
(continuous) Flow sensor qp= 0.6/1.0/1.5/2.5 m³/h
L=190 mm
a) connection type: thread G1“
b) connection type: flanges DN20

a)

b)

10 | AI384640298387en-010103 © Danfoss | Energy Meters | 2022.03


Data sheet SonoMeter 40

Dimensions
(continuous) Flow sensor qp= 3.5 m³/h
L=260 mm
a) connection type: thread G1 1/4“
b) connection type: flanges DN25
c) connection type: flanges DN32

a)

b)

c)

© Danfoss | Energy Meters | 2022.03 AI384640298387en-010103 | 11


Data sheet SonoMeter 40

Dimensions
(continuous) Flow sensor qp= 6 m³/h
L=260 mm.
a) connection type: thread G1 1/4“
b) connection type: flanges DN25
c) connection type: flanges DN32

a)

b)

c)

12 | AI384640298387en-010103 © Danfoss | Energy Meters | 2022.03


Data sheet SonoMeter 40

Dimensions
(continuous) Flow sensor qp= 10.0 m³/h
L=300 mm
a) connection type: thread G2“
b) connection type: flanges DN40

a)

b)

Flow sensor qp= 15 m³/h


L=270 mm
connection type: flanges DN50

© Danfoss | Energy Meters | 2022.03 AI384640298387en-010103 | 13


Data sheet SonoMeter 40

Dimensions
(continuous) Flow sensor qp= 25 m³/h
L=300 mm
connection type: flanges DN65

Flow sensor qp= 40 m³/h


L=300 mm
connection type: flanges DN80

Flow sensor qp= 60 m³/h


L=360 mm
connection type: flanges DN100

14 | AI384640298387en-010103 © Danfoss | Energy Meters | 2022.03


Data sheet SonoMeter 40

Weight Connection type Weight of the meter,


(and length) maximum
of the flow sensor (kg)
G3/4“ (110 mm) 0.7
G3/4“ (165 mm) 0.8
G1“ (110 mm) 0.7
G1“ (130 mm) 0.8
G1“ (190 mm) 0.9
DN20 (190 mm) 2.5
G1 ¼“ 3.2
DN25 5.6
DN32 6.0
G2“ 3.7
DN40 6.8
DN50 8.5
DN65 13
DN80 15
DN100 18

Ordering
SonoMeter 40 - Heating
Nominal flow, size and Cable length Cable length Communication
connection type Installation transducer cable temperature sensor Power supply integrated Modules Energy unit Code no.
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2000
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2001
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2026
DN15 qp0.6m³/h G¾ Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2027
110mm Return 1.2m 1.5m Mains power 230V MBus - kWh 187F2052
Supply 1.2m 1.5m Mains power 230V MBus - kWh 187F2053
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2084
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2085
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2002
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2003
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2028
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2029
DN15 qp1.5m³/h G¾ Return 1.2m 1.5m Mains power 230V MBus - kWh 187F2054
110mm Supply 1.2m 1.5m Mains power 230V MBus - kWh 187F2055
Return 1.2m 1.5m Mains power 230V MBus - MWh 187F2078
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2086
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2087
Supply 1.2m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2118
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2004
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2005
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2030
DN20 qp1.5m³/h G1 Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2031
130mm Return 1.2m 1.5m Mains power 230V MBus - kWh 187F2056
Supply 1.2m 1.5m Mains power 230V MBus - kWh 187F2057
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2088
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2089
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2006
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2007
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2032
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2033
DN20 qp2.5m³/h G1
Return 1.2m 1.5m Mains power 230V MBus - kWh 187F2058
130mm
Supply 1.2m 1.5m Mains power 230V MBus - kWh 187F2059
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2090
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2091
Supply 1.2m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2119

© Danfoss | Energy Meters | 2022.03 AI384640298387en-010103 | 15


Data sheet SonoMeter 40

Nominal flow, size and Cable length Cable length Communication


connection type Installation transducer cable temperature sensor Power supply integrated Modules Energy unit Code no.
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2008
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2009
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2034
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2035
DN20 qp2.5m³/h G1
Return 1.2m 1.5m Mains power 230V MBus - kWh 187F2060
190mm
Supply 1.2m 1.5m Mains power 230V MBus - kWh 187F2061
Return 1.2m 1.5m Mains power 230V MBus - MWh 187F2079
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2092
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2093
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2010
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2011
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2036
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2037
DN25 qp3.5m³/h G1¼ Return 2.5m 3m Mains power 230V MBus - kWh 187F2062
260mm Supply 2.5m 3m Mains power 230V MBus - kWh 187F2063
Return 1.2m 1.5m Mains power 230V MBus - MWh 187F2080
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2094
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2095
Supply 1.2m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2120
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2012
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2013
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2038
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2039
DN25 qp6.0m³/h G1¼ Return 2.5m 3m Mains power 230V MBus - kWh 187F2064
260mm Supply 2.5m 3m Mains power 230V MBus - kWh 187F2065
Return 1.2m 1.5m Mains power 230V MBus - MWh 187F2081
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2096
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2097
Supply 1.2m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2121
DN25 qp6.0m³/h
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2162
threaded flange 260mm
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2014
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2015
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2040
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2041
DN40 qp10m³/h G2 Return 2.5m 3m Mains power 230V MBus - kWh 187F2066
300mm Supply 2.5m 3m Mains power 230V MBus - kWh 187F2067
Return 2.5m 3m Mains power 230V MBus - MWh 187F2082
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2098
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2099
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2122
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2016
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2017
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2042
DN40 qp10m³/h Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2043
threaded flange 300mm Return 2.5m 3m Mains power 230V MBus - kWh 187F2068
Supply 2.5m 3m Mains power 230V MBus - kWh 187F2069
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2100
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2101
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2018
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2019
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2044
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2045
Return 2.5m 3m Mains power 230V MBus - kWh 187F2070
DN50 qp15m³/h flange Supply 2.5m 3m Mains power 230V MBus - kWh 187F2071
270mm Return 2.5m 3m Mains power 230V MBus - MWh 187F2083
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2102
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2103
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2110
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2111
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2123

16 | AI384640298387en-010103 © Danfoss | Energy Meters | 2022.03


Data sheet SonoMeter 40

Nominal flow, size and Cable length Cable length Communication


connection type Installation transducer cable temperature sensor Power supply integrated Modules Energy unit Code no.
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2020
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2021
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus+OMS - MWh 187F2046
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus+OMS - MWh 187F2047
DN65 qp25m³/h Return 5m 5m Mains power 230V MBus - MWh 187F2072
flange 300mm Supply 5m 5m Mains power 230V MBus - MWh 187F2073
Return 5m 10m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2104
Supply 5m 10m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2105
Return 5m 10m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2112
Supply 5m 10m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2113
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2022
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2023
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus+OMS - MWh 187F2048
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus+OMS - MWh 187F2049
DN80 qp40m³/h Return 5m 5m Mains power 230V MBus - MWh 187F2074
flange 300mm Supply 5m 5m Mains power 230V MBus - MWh 187F2075
Return 5m 10m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2106
Supply 5m 10m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2107
Return 5m 10m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2114
Supply 5m 10m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2115
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2024
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2025
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus+OMS - MWh 187F2050
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus+OMS - MWh 187F2051
DN100 qp60m³/h Return 5m 5m Mains power 230V MBus - MWh 187F2076
flange 360mm Supply 5m 5m Mains power 230V MBus - MWh 187F2077
Return 5m 10m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2108
Supply 5m 10m Battery 3.6V DC (2 AA-cell) MBus - GJ 187F2109
Return 5m 10m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2116
Supply 5m 10m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2117

Ordering
SonoMeter 40 - Combined heating and cooling
Nominal flow, size and Cable length Cable length Communication
connection type Installation transducer cable temperature sensor Power supply integrated Modules Energy unit Code no.
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2600
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2601
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2626
Return 1.2m 1.5m Mains power 230V MBus - kWh 187F2639
Return 1.2m 1.5m Mains power 230V MBus+OMS - kWh 187F2652
DN15 qp0.6m³/h G¾ Return 1.2m 1.5m Mains power 230V - Modbus kWh 187F2665
110mm Return 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2678
Supply 1.2m 1.5m Mains power 230V - BACnet kWh 187F2691
Supply 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2704
Supply 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2725
Return 1.2m 1.5m Mains power 230V - BACnet kWh 187F2738
Return 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2751
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2602
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2603
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2627
Return 1.2m 1.5m Mains power 230V MBus - kWh 187F2640
Return 1.2m 1.5m Mains power 230V MBus+OMS - kWh 187F2653
DN15 qp1.5m³/h G¾ Return 1.2m 1.5m Mains power 230V - Modbus kWh 187F2666
110mm Return 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2679
Supply 1.2m 1.5m Mains power 230V - BACnet kWh 187F2692
Supply 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2705
Supply 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2726
Return 1.2m 1.5m Mains power 230V - BACnet kWh 187F2739
Return 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2752

© Danfoss | Energy Meters | 2022.03 AI384640298387en-010103 | 17


Data sheet SonoMeter 40

Nominal flow, size and Cable length Cable length Communication


connection type Installation transducer cable temperature sensor Power supply integrated Modules Energy unit Code no.
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2604
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2605
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2628
Return 1.2m 1.5m Mains power 230V MBus - kWh 187F2641
Return 1.2m 1.5m Mains power 230V MBus+OMS - kWh 187F2654
DN20 qp15m³/h G1 Return 1.2m 1.5m Mains power 230V - Modbus kWh 187F2667
130mm Return 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2680
Supply 1.2m 1.5m Mains power 230V - BACnet kWh 187F2693
Supply 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2706
Supply 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2727
Return 1.2m 1.5m Mains power 230V - BACnet kWh 187F2740
Return 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2753
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2606
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2607
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2629
Return 1.2m 1.5m Mains power 230V MBus - kWh 187F2642
Return 1.2m 1.5m Mains power 230V MBus+OMS - kWh 187F2655
DN20 qp2.5m³/h G1 Return 1.2m 1.5m Mains power 230V - Modbus kWh 187F2668
130mm Return 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2681
Supply 1.2m 1.5m Mains power 230V - BACnet kWh 187F2694
Supply 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2707
Supply 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2728
Return 1.2m 1.5m Mains power 230V - BACnet kWh 187F2741
Return 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2754
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2608
Supply 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2609
Return 1.2m 1.5m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2630
Return 1.2m 1.5m Mains power 230V MBus - kWh 187F2643
Return 1.2m 1.5m Mains power 230V MBus+OMS - kWh 187F2656
DN20 qp2.5m³/h G1 Return 1.2m 1.5m Mains power 230V - Modbus kWh 187F2669
190mm Return 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2682
Supply 1.2m 1.5m Mains power 230V - BACnet kWh 187F2695
Supply 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2708
Supply 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2729
Return 1.2m 1.5m Mains power 230V - BACnet kWh 187F2742
Return 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2755
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2610
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2611
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2631
Return 2.5m 3m Mains power 230V MBus - kWh 187F2644
Return 2.5m 3m Mains power 230V MBus+OMS - kWh 187F2657
DN25 qp3.5m³/h G1¼ Return 1.2m 1.5m Mains power 230V - Modbus kWh 187F2670
260mm Return 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2683
Supply 1.2m 1.5m Mains power 230V - BACnet kWh 187F2696
Supply 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2709
Supply 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2730
Return 1.2m 1.5m Mains power 230V - BACnet kWh 187F2743
Return 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2756
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2612
Supply 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2613
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2632
Return 2.5m 3m Mains power 230V MBus - kWh 187F2645
Return 2.5m 3m Mains power 230V MBus+OMS - kWh 187F2658
DN25 qp6.0m³/h G1¼ Return 1.2m 1.5m Mains power 230V - Modbus kWh 187F2671
260mm Return 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2684
Supply 1.2m 1.5m Mains power 230V - BACnet kWh 187F2697
Supply 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2710
Supply 1.2m 1.5m Mains power 24V AC/DC - Modbus kWh 187F2731
Return 1.2m 1.5m Mains power 230V - BACnet kWh 187F2744
Return 1.2m 1.5m Mains power 24V AC/DC - BACnet kWh 187F2757

18 | AI384640298387en-010103 © Danfoss | Energy Meters | 2022.03


Data sheet SonoMeter 40

Nominal flow, size and Cable length Cable length Communication


connection type Installation transducer cable temperature sensor Power supply integrated Modules Energy unit Code no.
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2614
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2615
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2633
Return 2.5m 3m Mains power 230V MBus - kWh 187F2646
Return 2.5m 3m Mains power 230V MBus+OMS - kWh 187F2659
DN40 qp10m³/h G2 Return 2.5m 3m Mains power 230V - Modbus kWh 187F2672
300mm Return 2.5m 3m Mains power 24V AC/DC - Modbus kWh 187F2685
Supply 2.5m 3m Mains power 230V - BACnet kWh 187F2698
Supply 2.5m 3m Mains power 24V AC/DC - BACnet kWh 187F2711
Supply 2.5m 3m Mains power 24V AC/DC - Modbus kWh 187F2732
Return 2.5m 3m Mains power 230V - BACnet kWh 187F2745
Return 2.5m 3m Mains power 24V AC/DC - BACnet kWh 187F2758
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2616
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2617
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2634
Return 2.5m 3m Mains power 230V MBus - kWh 187F2647
Return 2.5m 3m Mains power 230V MBus+OMS - kWh 187F2660
DN40 qp10m³/h Return 2.5m 3m Mains power 230V - Modbus kWh 187F2673
threaded flange
300mm Return 2.5m 3m Mains power 24V AC/DC - Modbus kWh 187F2686
Supply 2.5m 3m Mains power 230V - BACnet kWh 187F2699
Supply 2.5m 3m Mains power 24V AC/DC - BACnet kWh 187F2712
Supply 2.5m 3m Mains power 24V AC/DC - Modbus kWh 187F2733
Return 2.5m 3m Mains power 230V - BACnet kWh 187F2746
Return 2.5m 3m Mains power 24V AC/DC - BACnet kWh 187F2759
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2618
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2619
Return 2.5m 3m Battery 3.6V DC (2 AA-cell) MBus+OMS - kWh 187F2635
Return 2.5m 3m Mains power 230V MBus - kWh 187F2648
Return 2.5m 3m Mains power 230V MBus+OMS - kWh 187F2661
Return 2.5m 3m Mains power 230V - Modbus kWh 187F2674
DN50 qp15m³/h flange Return 2.5m 3m Mains power 24V AC/DC - Modbus kWh 187F2687
270mm Supply 2.5m 3m Mains power 230V - BACnet kWh 187F2700
Supply 2.5m 3m Mains power 24V AC/DC - BACnet kWh 187F2713
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2717
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2718
Supply 2.5m 3m Mains power 24V AC/DC - Modbus kWh 187F2734
Return 2.5m 3m Mains power 230V - BACnet kWh 187F2747
Return 2.5m 3m Mains power 24V AC/DC - BACnet kWh 187F2760
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2620
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2621
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus+OMS - MWh 187F2636
Return 5m 5m Mains power 230V MBus - MWh 187F2649
Return 5m 5m Mains power 230V MBus+OMS - MWh 187F2662
Return 5m 5m Mains power 230V - Modbus MWh 187F2675
DN65 qp25m³/h Return 5m 5m Mains power 24V AC/DC - Modbus MWh 187F2688
flange 300mm Supply 5m 5m Mains power 230V - BACnet MWh 187F2701
Supply 5m 5m Mains power 24V AC/DC - BACnet MWh 187F2714
Return 5m 10m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2719
Supply 5m 10m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2720
Supply 5m 5m Mains power 24V AC/DC - Modbus MWh 187F2735
Return 5m 5m Mains power 230V - BACnet MWh 187F2748
Return 5m 5m Mains power 24V AC/DC - BACnet MWh 187F2761

© Danfoss | Energy Meters | 2022.03 AI384640298387en-010103 | 19


Data sheet SonoMeter 40

Nominal flow, size and Cable length Cable length Communication


connection type Installation transducer cable temperature sensor Power supply integrated Modules Energy unit Code no.
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2622
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2623
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus+OMS - MWh 187F2637
Return 5m 5m Mains power 230V MBus - MWh 187F2650
Return 5m 5m Mains power 230V MBus+OMS - MWh 187F2663
Return 5m 5m Mains power 230V - Modbus MWh 187F2676
DN80 qp40m³/h Return 5m 5m Mains power 24V AC/DC - Modbus MWh 187F2689
flange 300mm Supply 5m 5m Mains power 230V - BACnet MWh 187F2702
Supply 5m 5m Mains power 24V AC/DC - BACnet MWh 187F2715
Return 5m 10m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2721
Supply 5m 10m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2722
Supply 5m 5m Mains power 24V AC/DC - Modbus MWh 187F2736
Return 5m 5m Mains power 230V - BACnet MWh 187F2749
Return 5m 5m Mains power 24V AC/DC - BACnet MWh 187F2762
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2624
Supply 5m 5m Battery 3.6V DC (2 AA-cell) MBus - MWh 187F2625
Return 5m 5m Battery 3.6V DC (2 AA-cell) MBus+OMS - MWh 187F2638
Return 5m 5m Mains power 230V MBus - MWh 187F2651
Return 5m 5m Mains power 230V MBus+OMS - MWh 187F2664
Return 5m 5m Mains power 230V - Modbus MWh 187F2677
DN100 qp60m³/h Return 5m 5m Mains power 24V AC/DC - Modbus MWh 187F2690
flange 360mm Supply 5m 5m Mains power 230V - BACnet MWh 187F2703
Supply 5m 5m Mains power 24V AC/DC - BACnet MWh 187F2716
Return 5m 10m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2723
Supply 5m 10m Battery 3.6V DC (2 AA-cell) MBus - kWh 187F2724
Supply 5m 5m Mains power 24V AC/DC - Modbus MWh 187F2737
Return 5m 5m Mains power 230V - BACnet MWh 187F2750
Return 5m 5m Mains power 24V AC/DC - BACnet MWh 187F2763

20 | AI384640298387en-010103 © Danfoss | Energy Meters | 2022.03


Data sheet SonoMeter 40

Ordering Product Designation Quantity Code no.


Accessories Optical head Optical head OG-1-USB 1 pc 187F3112
Sono40 Battery 3.6V DC A-cell 1 pc 187F2970
Power supply
Sono40 Mains unit 24V AC/DC + 230V AC 1 pc 187F2971
Sono40 M-Bus module 1 pc 187F2972
Communication
Sono40 Modbus RTU module 1 pc 187F2973
modules
Sono40 BACnet MSTP module 1 pc 187F2974
Pt 500 / Ø 5.2 mm / 1.5 m cable, MID 1 pair 187F3125
Temperature sensor Ø Pt 500 / Ø 5.2 mm / 3 m cable, MID 1 pair 187F3127
5.2 mm Pt500 / Ø 5.2 mm / 5 m cable, MID 1 pair 187F3390
Pt500 / Ø 5.2 mm / 10 m cable, MID 1 pair 187F3391
Pt500 / Ø 6.0 mm / 3 m cable, MID 1 pair 187F3123
Temperature sensor Ø
Pt500 / Ø 6.0 mm / 5 m cable, MID 1 pair 187F3124
6.0 mm
Pt500 / Ø 6.0 mm / 10 m cable, MID 1 pair 187F3389
DN15 - 1/2" for direct sensor 1 pc 187F0593
Ball valve
for Ø 5.2 mm DN20 - 3/4" for direct sensor 1 pc 187F0592
temperature sensor DN25 - 1" for direct sensor 1 pc 187F0591
Single pack
DN32 - 5/4" for direct sensor 1 pc 187F3448
DN15 - for direct sensor,12pc 12 pcs. 087H0118
Ball valve
for Ø 5.2 mm DN20 - for direct sensor,12pc 12 pcs. 087H0119
temperature sensor DN25 - for direct sensor,12pc 12 pcs. 087H0120
Multi pack
DN32 - for direct sensor,12pc 12 pcs. 187F3449
DN15: G½”, G½”, G½” PN25 130 °C 1 pc 014U1959
DN20: G¾”, G½”, G¾” PN25 130 °C 1 pc 014U1960
T-Fitting
DN25: G1”, G½”, G1” PN25 130 °C 1 pc 014U1961
DN32: G11/4”, G½”, G11/4” PN25 130 °C 1 pc 014U1943
Ø 5.2 mm, brass, 35 mm length 1 pair 087G6053
Ø 5.2 mm, brass, 52 mm length 1 pair 087G6054
Ø 5.2 mm, brass, 85 mm length 1 pair 087G6055
Pockets Ø 5.2 mm, brass,120 mm length 1 pair 087G6056
for Ø 5.2 mm
temperature sensors Ø 5.2 mm, stainless steel, 85 mm length 1 pair 087G6057
Ø 5.2 mm, stainless steel, 120 mm length 1 pair 087G6058
Ø 5.2 mm, stainless steel, 155 mm length 1 pair 087G6059
Ø 5.2 mm, stainless steel, 210 mm length 1 pair 087G6060
Ø 6.0 mm, brass, 40 mm length 1 pair 087G6061
Ø 6.0 mm, brass, 85 mm length 1 pair 087G6062
Pockets Ø 6.0 mm, brass, 120 mm length 1 pair 087G6063
for Ø 6.0 mm Ø 6.0 mm, stainless steel, 85 mm length 1 pair 087G6064
temperature sensors Ø 6.0 mm, stainless steel, 120 mm length 1 pair 087G6065
Ø 6.0 mm, stainless steel, 155 mm length 1 pair 087G6066
Ø 6.0 mm, stainless steel, 210 mm length 1 pair 087G6067
DN15 G3/4”-R1/2” PN25 130 °C 1 pair 087G6071
DN20 G1”-R3/4” PN25 130 °C 1 pair 087G6072
Tailpiece connection set
DN25 G1 1/4”-R1” PN25 130 °C 1 pair 087G6073
DN40 G2"-R1 1/2" PN25 130°C 1 pair 087G6074
R½” to M10x1 (1pc) - incl. copper gasket for flat sealing. PN25 130 °C 1 pc. 087G6075
Adapter R½” to M10x1 (32pcs.) - incl. copper gasket for flat sealing. PN25 130 °C 32 pcs. 087G6076
for Ø 5.2 mm
temperature sensor R½” to M10x1 (1pc) - conical thread for sealing with hemp. PN25 130 °C 1 pcs. 014U1941
R½” to M10x1 (32pcs.) - conical thread for sealing with hemp. PN25 130 °C 32 pcs. 014U1935
Adapter M10x1 plastic installation set 20 pcs. 087G6077
for Ø 5.2 mm
temperature sensor M10x1 brass installation set 20 pcs. 087G6078

© Danfoss | Energy Meters | 2022.03 AI384640298387en-010103 | 21


Data sheet SonoMeter 40

22 | AI384640298387en-010103 © Danfoss | Energy Meters | DCS-SGDPT/SI | 2022.03

You might also like