0BU
The Compressed Air and Gas Institute (CAGI) sponsors the Performance Verification
Program for Rotary Compressors. The program provides a uniform and commercially
practical means of verifying participants’ claimed ratings. Compliance with the
provisions of the latest edition of ISO 1217, Displacement Compressors-Acceptance
Tests, is mandatory for all participants.
The ratings certified under this program are displayed in the standard CAGI datasheet
format on datasheets published on participants’ websites and in the participants published
literature. The verification seal, which appears on units and on participants’ published
literature, is the participants’ public representation that the stated air flow capacities and
efficiencies of compressors have been verified by an independent laboratory.
The flow and pressure ratings in this directory are provided along with model number
only to help identify the specific model that was tested by the administrator. Consult a
U U
copy of the manufacturer’s data sheet for more detailed information. Datasheets can be
located via the following links:
• Atlas Copco
HU
• Boge
HU
• Chicago Pneumatic
• Elgi
• FS Curtis
HU UH
• Gardner Denver
HU
• Ingersoll Rand
HU
• Kaeser
HU
• Mattei
• Quincy
HU
• Sullair
HU
• Sullivan-Palatek
03-18
Participant List
1BU
Atlas Copco
HU UH
Boge
HU
Chicago Pneumatic
Elgi
FS Curtis
HU
Gardner Denver
HU
Ingersoll Rand
HU
Kaeser
HU UH
Mattei
Quincy
HU
Sullair
HU UH
Sullivan-Palatek
03-18
3B
Rated
Date Model Number Rated Flow Result
Pressure
-- GA55+-125AP 333 125 Passed
-- GA90S-125A 534 125 Passed
-- GA45-125AP 246 125 Passed
-- GA37+-125AP 227 125 Passed
-- GA55-125AP 320 125 Passed
-- GA26+-125AP 157 125 Passed
-- GA37-125AP 227 125 Passed
-- GA75-125 AP 414 125 Passed
GA90VSD-175
-- 603 125 Passed
AP
-- GA90+-125 AP 581 125 Passed
-- GA75-125AP 414 125 Passed
5-13 GA55-125 327 125 Passed
6-13 GA75VSD-175 488 125 Passed
6-13 GA26+-125 157.1 125 Passed
5-14 GA26VSD+ 180.8 102 Passed
5-14 GA90-125 AP 566 125 Passed
5-14 G 110-125 678 125 Passed
4-15 GA45 VSD-175 284 125 Passed
4-15 GA18+ -125 113 125 Passed
8-15 G160 - 125 930 125 Passed
GA45VSD-175
12-17 284 125 Passed
AP
12-17 GA55-125AP 327 125 Passed
Back to Overview
HU U
4B
Back to Overview
HU U
Back to Overview
HU U
6B
Elgi
Back to Overview
HU U
Rated Rated
Date Model Number Result
Flow Pressure
-- RS75D 333 125 Passed
-- SE50-125 205 125 Passed
-- SE50-100 222 100 Passed
-- RS50F-100 220 100 Passed
-- RS25 111 100 Passed
-- RS40 173 125 Passed
-- SE30 113 125 Passed
-- RS50 186 150 Passed
-- SE 25 100 125 Passed
-- GSV-30D 131 100 Passed
-- RS100F 374 150 Passed
6-13 SE-30 126 100 Passed
8-14 GSV-100 430 125 Passed
8-14 RSB-50 200 125 Passed
10-14 SEG15 14 125 Passed
7-15 RS100 440 100 Passed
10-15 FNB22CXX4JXXX 203.4 125 Passed
11-15 FNB37DXX4JXXX 116.1 125 Passed
6-16 NXV 37 211.0 125 Passed
6-16 RSB-30 123.0 125 Passed
6-16 NxB30 170.0 125 Passed
10-17 FNV30DXX4JXPC 173 125 Passed
10-17 FND90FXX4HXPC 563 100 Passed
10-17 FRD75FUXXA4J1XXXX 330 125 Passed
Back to Overview
HU U
Rated Rated
Date Model Number Result
Flow Pressure
-- EBPST-100-100 psig 495 100 Passed
-- EBMST-75-125 psig 320 125 Passed
-- EBM99K/EBM ST-75-125 320 125 Passed
-- EBQ99M/EBQ-ST-150-125 618 125 Passed
-- EBEST-30 120 125 Passed
-- EBHST-50 205 125 Passed
-- EBE99Q02 97 125 Passed
-- EDE99N02E 185 125 Passed
-- EBE99Q01E 97 125 Passed
-- VS70 436 100 Passed
-- EBP99K01 450 125 Passed
5-13 EBH99H02E 205 125 Passed
5-13 EBP99K01 450 125 Passed
5-13 VS25-40A03 242 100 Passed
9-13 EBP99K01 450 125 Passed
5-14 VS80 556 110 Passed
5-14 INT 50 hp, EFD, 125 193 125 Passed
8-14 SAV 125 hp, EAQ, 125 608 125 Passed
2-15 ST-50 238 100 Passed
2-15 VS30 213 100 Passed
2-15 Apex VS 18 94.6 125 Passed
6-16 L45 269.4 100 Passed
6-16 EnviroAire T90 562 115 Passed
8-16 L23RS 146 100 Passed
9-17 ApexVs18-125 90.0 125 Passed
9-17 STG-50 239.0 100 Passed
03-18
Back to Overview
HU U
8B
Rated
Date Model Number Rated Flow Result
Pressure
-- SSR-EP75 323 125 Passed
-- SSR-EP100 434 125 Passed
-- R110IU-A-125 690 125 Passed
-- SSR-EP60SS 246 125 Passed
-- EP75 323 125 Passed
-- EPE50 211 125 Passed
-- R90i-A-125 566 125 Passed
-- UP6-25 98 125 Passed
-- UP6-50 208 125 Passed
-- R55N 312 135 Passed
-- R90N 513.4 135 Passed
-- R90i 566 115 Passed
4-13 R75N-A100 417.9 135 Passed
4-13 R55I-A125 328 115 Passed
4-13 UP625-125 98 125 Passed
5-14 IRN25H-CC-150 99.6 125 Passed
5-14 UP6 40-125 177 125 Passed
5-14 UP6 20-125 77 125 Passed
2-15 UP6-30 117 125 Passed
2-15 R45i 253 115 Passed
3-15 R45N-A100 262 100 Passed
5-16 R37IE-A125 217 115 Passed
5-16 IRN30H-CC-100 130.6 100 Passed
9-16 H100A 411 125 Passed
Failed and
3-18 R37NE 211 135
Re-rated
03-18
Back to Overview
HU U
Rated
Date Model Number Rated Flow Result
Pressure
-- CSD 75 345 115 Passed
-- CSD 100 494 115 Passed
-- CSD 125 566 115 Passed
-- DSD 125 570 115 Passed
-- ASD 40S 162 115 Passed
-- BSD 50 236 115 Passed
-- ASD 30 132 115 Passed
-- BSD 40 193 115 Passed
-- ASD25 112 115 Passed
-- SFC90S 483.8 125 Passed
-- CSD125 567 115 Passed
3-13 SM7.5 32 115 Passed
5-13 SFC75S 441 125 Passed
5-13 CSD75 345 115 Passed
6-14 SK 20 - 125 88 115 Passed
8-14 BSD 60 288 115 Passed
9-14 SFC110S 588 125 Passed
3-15 SFC 75S 441 125 Passed
3-15 CSD100S 417 115 Passed
3-15 AS 30 141 115 Passed
5-16 CSD 60-125 290 115 Passed
4-16 AS-25 120 115 Passed
5-16 SFC 55 357 125 Passed
8-17 BSD 50 236 115 Passed
8-17 SFC 30S 171 125 Passed
8-17 DSD 125 598 115 Passed
Back to Overview
HU U
Rated
Date Model Number Rated Flow Result
Pressure
03-14 AC 18LX 123 100 Passed
10-14 AC 22 131 100 Passed
10-14 Maxima 30 222 100 Passed
2-15 AC15HX 91.8 140 Passed
2-15 Optima 15 94.7 100 Passed
2-15 AC 37LX 246 100 Passed
2-16 AC 11 LX 70 100 Passed
Failed and
2-16 Optima 37 228.8 102
Re-rated
Failed and
2-16 Maxima 55 425 100
Re-rated
Failed and
1-18 Optima 30 197.9 102
Re-rated
Failed and
1-18 Maxima 75X 595 102
Re-rated
Failed and
1-18 AC45 LX 301 102
Re-rated
Back to Overview
HU U
Rated
Date Model Number Rated Flow Result
Pressure
-- QGB-50 238 100 Passed
-- QSI-600 630 100 Passed
-- QSI-500 495 100 Passed
-- QGD-50 223 110 Passed
-- QSI-750 745 100 Passed
-- QGD-30 132.5 100 Passed
-- QGD-40 186 100 Passed
-- QGD-50 226 100 Passed
-- QGV-100 470.9 100 Passed
-- QSI-500i 495 100 Passed
6-13 QGV-50 226.1 100 Passed
5-14 QGV 30 135.7 100 Passed
5-14 QGS 100-125 434 125 Passed
9-14 QGS-60 248 125 Passed
3-15 QSI 120 117 100 Passed
3-15 QGV25 104.3 125 Passed
3-15 QSI 140 136 100 Passed
5-16 QGV-40 185.3 100 Passed
5-16 QGS-25 92 125 Passed
5-16 QGS50c 208 125 Passed
Failed and
12-17 92.6 125
QGD 20 Re-rated
Failed and
12-17 229.9 125
QSI-50 Re-rated
Failed and
12-17 141.3 125
QGDV 30 Re-rated
Back to Overview
HU U
1B
Rated
Date Model Number Rated Flow Result
Pressure
-- LS160-75HAC 346 125 Passed
-- 7509/AC 444 125 Passed
LS200S-
-- 683 125 Passed
150HAC
-- 4509/A 267 125 Passed
-- 1809/A 106 125 Passed
-- 2209/A 127 125 Passed
-- 3709 222 125 Passed
-- 4509P 260 125 Passed
-- 3009V 163 125 Passed
-- 1809V 105 125 Passed
-- 4509V 260 125 Passed
6-13 7509V 454 125 Passed
6-13 7509 444 125 Passed
9-13 ST1109 63.5 125 Passed
9-13 3009 160 125 Passed
5-14 2209V 99 125 Passed
5-14 5509-AC 341 125 Passed
5-14 1809e 99.3 125 Passed
11-15 ST3008 160 115 Passed
8-15 TS20-100 HAC 575 100 Passed
11-15 Senergy 3009B 183 125 Passed
6-16 3709VB 225 125 Passed
9-16 ST3008 160 115 Passed
9-16 ST3708 219 115 Passed
9-17 1109e 60.2 125 Passed
03-18
Back to Overview
HU U
Rated
Date Model Number Rated Flow Result
Pressure
9-13 75UDMBW 325 125 Passed
6-13 25D 105 125 Passed
5-14 50UDG 225 125 Passed
10-14 100UDG VFD 425 125 Passed
8-15 20 D 78 125 Passed
8-15 40 UD 160 125 Passed
9-15 40 UDVFD 165 125 Passed
7-16 SP16 100VFD 440.1 125 Passed
7-16 30DG 120 125 Passed
7-16 SP16 100 441 125 Passed
8-17 SP 20 UD 545 125 Passed
8-17 L50 UD VFD 204 100 Passed
8-17 40 DG 150.1 125 Passed
Back to Overview