Wolf Guard
Wolf Guard
Wolf Guard
User’s Manual
♦ Users can make calls by using the keypad on alarm panel, just like a telephone
♦ One-key-control function: Out (away) Arm, Home (Stay) Arm, Remote Arm
♦ SOS, fire, gas, door, hall, window, balcony, and boundary place zone descriptions
♦ “Listen in “ function
***New: Now include build-in wireless transmitter to trigger wireless sirens, strobes, relay
units etc.
***New: You can now switch an appliance on/off from your cellphone
LCD Display
1. Initialization
Insert a SIM card in the SIM card slot in the back of the unit.
Note: SIM card must not have a password set, please use a cellphone to remove the password
from the sim card if password protected.
The system must be completely switched of when inserting the SIM card, the SIM card is only
initialized when the unit is powered on. Inserting a new SIM card or inserting the SIM card after
power on the SIM card will not be registered.
Once the SIM card is inserted, plug the power adaptor in, and switch the power switch in the back
of the unit to the on position.
Note: The power switch is used to power on the system's internal backup battery supply. In the
“off” position the backup batteries can not charge and the system can not use the battery backup in
case of power outage.
When switching the alarm system on all the LED lights will go on for 2 seconds by a long beep to
indicate the system is ready.
The time clock will then displays on the LCD screen and the alarm system will connect to the
cellular network. While connecting to your cellular network the [GSM] icon on the LCD screen
will be flashing. When the unit detect the GSM network a long beep will indicate successful
detection. When the [GSM] indicator goes out the system will be in disarm status and ready to use
or program.
While the alarm system is disarmed, input the 4-digit settings password using the keypad on the
alarm unit and press [#] button to confirm. You will hear a voice prompt: please enter instruction.
LCD display:
To manually exit settings mode press [*] and [#] buttons, the main unit emits a long beep and exit
settings mode.
The [SET] indicator will go off and the system returns to disarm state.
3. Factory Reset
In some instances it is easier to clear all settings and redo all settings.
While the alarm is in disarm status, use the keypad to input [95175308246] and press [#] to
confirm, all the LED indicators will be on for 2 seconds and you will hear a long beep. The main
unit's settings will be cleared and restores to its factory settings successfully.
Operating method: [95175308246] + [#]
While in settings mode, use the keypad to enter [21], then input the remote controller
number [1-8], and then press [#] to confirm. The main unit emits a long beep and the [Signal]
indicator flickers once. You will hear a voice prompt “delete completed”.
While in settings mode, use the keypad to enter [23], input the defence zone number
you want to code [01~99], and then input [#] to confirm. The main unit emits a long beep and the
corresponding defence zone is displayed on the screen. You will hear a voice prompt “detector
coding”.
Then trigger a wireless detector to emit a wireless signal; after receiving the signal,
the main unit makes a long beep, and you will hear “coding completed” and the [ ] indicator goes
out.
LCD display:
While in settings mode, use the keypad to enter [24], then enter the defence zone
number you want to delete [01~99], and then input [#] to confirm. The main unit emits a long beep
and the defence zone indicator flickers once. You will hear a voice prompt “delete completed”.
While in settings mode, use the keypad to enter [30], then enter the new 4-digit password, finally
press [#] to confirm. The main unit will make a long beep and you will hear a voice prompt “setting
completed”.
LCD display:
While in settings mode, use the keypad to enter [31], then enter the new 4-digit password, and then
press [#] to confirm. The main unit will make a long beep and you will hear a voice prompt “setting
completed”.
LCD display:
Note:the user password and the settings password can not be the same
9. Clock Setting
While in settings mode, use the keypad to enter [32], then enter the last 2 digits [AA] of the present
year, the two digits [BB] of the month, the two digits [CC] of the day, the two digits [DD] of the
hour, the two digits [EE] of the minute, the two digits [FF] of the second, and finally enter [#] to
LCD display:
LCD display:
LCD display:
LCD display:
While in settings mode, use the keypad to enter [57] ~ [59], then input the SMS receiving number,
and then press [#] button to confirm. The main unit will make a beep, the [Signal] indicator will
flicker once and you will hear “setting completed”, which indicate setup successfully.
For example: delete the first SMS user number from the system
Operating method: [57][#]
While in settings mode, use the keypad to enter [60], then the defence zone number [01~99], then
input defence zone type [1~4], then input defence zone location number [1~8], and then select siren
on/off [0/1], finally press [#] to confirm. You will hear the main unit emit a long beep and a voice
prompt “setting completed”.
For example: set defence zone 12 to be 24-hour, fire alarm and siren on
Operating method: [60][12][3][2][1][#]
For example: set defence zone 12 as Home arm but not alarm
Operating method: [61][12][0][#]
While in settings mode, use the keypad to enter [701], and then press [#] to confirm.
The main unit will emit a beep and the [ ] indicator will go on, and do your recording for the next
10 seconds , record at 10cm away from the main unit with relative loud tone. In the next 10
seconds, the main unit will replay your message.
LCD display:
While in settings mode, use the keypad to enter [75] select if the siren should sounds or not [0/1]
and then press [#] to confirm. The main unit will emit a long beep and a voice prompt “setting
completed”.
LCD display:
When the panic button is pressed the siren can be set to sound or not.
While in settings mode, use the keypad to enter [76], and then [1/0], finally press [#]
to confirm. The main unit will make a long beep and a voice prompt “setting completed”.
Example: the 51st defence zone; the 7th alarming; alarming time:
12:10, August 1st, 2008.
Signal strength must be between 07-31. If it’s less than 07, you should change place.
The signal strength can also be viewed from the signal strength icon on the panel.
This icon indicates the signal strength. When the intensity number is 0-7, this icon will not be
shown; when it’s 8-15, this icon will be flashing; when the number is larger than 16, this icon will
be on the screen without flash.
29.IMEI Checking
In setting status, first input [88] and then press [#] to confirm. The 15-digit IMEI code will be
displayed separately in 4 pages (2 seconds per page) on the screen.
Operation Instructions
1. System statuses.
1) Arm: defence zone 1~99 will alarm when detectors are triggered
2) Home Arm: in home arm status, the defence zone which is set as [Home Arm] will alarm when
detectors are triggered.
3) Disarm: defence zone 1~99 will not alarm when detector are triggered (except 24 hours defence
zones)
4) System setup status: In this status, all defence zones will not alarm when detectors are triggered.
3. Keypad operation
Press [Out Home ] button on keypad, system will make one beep per second for a total of 100
Keypad Operation: Press [Out Home ] button, the system will enter arm status 100 seconds later.
Remote control operation: Press the button
LCD display:
LCD display:
Disarm
Main Unit Operation: Use the keypad to input the user password, then press [#] button. [Out
Home] or [At Home] lights will go off.
Remote Control Operation: Press the button on remote controller
LCD display:
13
If you answer the call, you will hear the pre-recorded voice recorded as explained earlier as well as
an artificial voice that gives the zone number that triggered the alarm..
You can set the alarm system via your telephone or mobile phone keypad.
Press [1]: arm, if finished successfully, you will hear a voice prompt “System armed”.
Press [2]: disarm, if finished successfully, you will hear a voice prompt “System disarmed”.
Press [3]: monitoring for 30 seconds, to continue monitoring, press [3] again to monitor for another
30 seconds.
Press [4]: two-way intercom for 30 seconds. You can’t operate the main unit during this time.
Press [5]: Linkage switch 1, 12V output on.
Press [6]: Linkage switch 1, 12V output off.
beep and the [Signal] indicator will be flashing. After the call, press [ ] button again, the main
unit will hang up the call and be in disarm status.
The alarm system will send power failure and recovery notifications via SMS when detecting power
loss to the alarm system.
Note: Only under Out Arm status, will the system send SMS power failure/ power recovery alerts.
Factory settings
Components list
• Main panel 1 pc,
• Remote controller 2 pcs,
• Siren 1 pc,
• PIR sensor 1 pc,
• Door sensor 1 pc,
• Place the control panel and all parts and accessories out of children’s reach.
• Keep the alarm system dry. Rain, humidity and various fluids or moisture will corrupt
the electronic circuit.
• Do not use or place the alarm system in a dirty location.
• Do no place the system in excessively hot locations. High temperature will shorten
the service life of electronic equipment, damage batteries, deform or even melt
some plastic parts.
• Do not place the system in excessively cold locations. Condensation may occur and
damage the circuit board of the alarm system.
Periodically:
Check the main unit every three months:
• Whether it can arm/disarm normally;
• Whether it can dial the number for alarm normally;
• Whether it can receive wireless detectors’ signal normally;
• Whether the back-up battery can work normally.
Tips
• Since the alarm system is continuously in operation or standby mode, the supply
adaptor of the control panel must be connected to a safe and reliable socket.
• Do not place the system near your bedroom or office table, the siren will make a
loud sound in the case of alarm, which may adversely affect your rest or work.
• If the alarm system will not be used for a long time, please disconnect the system
from the power supply.
• Please do not disassemble, repair or alter the products without permission, or it
may cause accidents and faults.
• Do not drop this product on the ground or on hard objects, as it may lead to
massive impact causing faults and damages.
• Without approval and consent of relevant authorities, please do not set “110”, “119”
Please read the suggestions above carefully and follow the instructions herein. If any of the
equipment does not work properly, please send it to the dealer or authorized service point for repair.
We will try our best to solve the problem for you as soon as possible.
20