Spesifikasi Loop Calibrator VC05s
Spesifikasi Loop Calibrator VC05s
Spesifikasi Loop Calibrator VC05s
Loop detection function, internal 24V circuit power supply, and simultaneous measurement of
current.
mA has a percentage display mode.
2. Analog output characteristics
Basic functions
DC current DCI
The maximum measurement accuracy is 0.05% and the measurement display is 5 digits.
Output settings can be manually increased or decreased by position.
DCI output includes active output (internal 24V power supply) and passive output (external 24V
power supply).
mA has a percentage display mode.
During DCI output, it can provide manual stepping and automatic waveform output functions.
The manual stepping output mode includes: 25% stepping and 100% stepping.
The output current is selectable from 0~20mA or 4~20mA.
Automatic wave output type includes: automatic step, sawtooth wave, triangle wave, and automatic
waveform working parameters can be configured.
3. Internal 24V circuit power supply.
4. It has maintenance setup functions, including
Auto power-off, backlight, flashlight
5. Others
The segment code is displayed on an LCD with a white backlight.
It has a LED flashlight for lighting.
It is powered by 3 AA battery cells. The battery compartment door is convenient for battery
replacement. Low-battery detection is available.
It is small, firm, reliable, suitable for field use, and cheap.
User-optional large-suction magnetic sling is provided.
Other characteristics:
Uncertainty includes standard uncertainty, hysteresis, nonlinearity, repeatability, and typical long-term stability over the period mentioned (K = 2).
Maximum applied voltage at input end: about 30Vpk; Maximum applied current at input end: about 25mA
The temperature range of internal temperature compensated sensor RJC is -10 to 50 C. The temperature measurement accuracy at 18 to 28 C is ±0.5 C, and the temperature
measurement accuracy at other temperature is ±1C. Cold end compensation time is 10S/ times.
Temperature coefficient: 0.1 × basic accuracy/℃ (temperature range < 18℃ or > 28℃)
Input output function [Used within one year after calibration, 23℃±5℃, 20-70% RH, accuracy =+/-(% set point + reading %)]
Measurement
Range Measurement range Resolution Accuracy Remarks
function
DC voltage
35V -35.000V~35.000V 0.001V 0.02%+2mV Input resistance: approximately 1MΩ
DCV
Other characteristics:
Uncertainty includes standard uncertainty, hysteresis, nonlinearity, repeatability, and typical long-term stability over the period mentioned (K = 2).
Quality standard: developed, designed and manufactured in accordance with TUV ISO 9001.