Bbasn NRR A1 ZZ DR A 00309 Typical Higher Parapet Detail
Bbasn NRR A1 ZZ DR A 00309 Typical Higher Parapet Detail
Bbasn NRR A1 ZZ DR A 00309 Typical Higher Parapet Detail
NOTE:
Required U-Values:
• Walls - 0.15 W / m2K Compressible filler
• Floors - 0.13 W / m2K
• Roofs - 0.11 W / m2K 42.430
Upper Parapet
An overall airtightness of *.* m2
/hm2 @ 50Pa is to be achieved
12mm marine quality plywood over wall head
TO BE DICUSSED WITH
3mm thick PPC aluminium 50 mm Insulated Cavity Closer with DPC
capping system on galvanised
zed spaces fized to substrate
Weep vent
STRCUTRAL
details and specifications
9.5mm OSB Sheathing Board
(All joints to be taped and sealed)
50mm Air Cavity This drawing has been prepared solely for the
use of STIRLING COUNCIL and there are no
representations of any kind made by NORR
Consultants Limited to any party with whom
102.5mm Facing Brick Roof membrane dressed full width of plywood NORR Consultants Limited has not entered
into a contract
and capping support by sub contractor This drawing must not be used, reproduced or
Breather Membrane (lapped over revised without written permission.
Roof membrane dressed full height of
DPC cloak)
insualtion upstand This drawing shall not be used for
construction purposes until the
“CONSTRUCTION” status appears under the
Membrane TBC Sheet Status.
TO BE DICUSSED WITH
(TO TIMBER KIT SUPPLIERS DESING) 180mm Rigid PIR (tbc) insulation board Do not scale from hard copy drawings
VCL
18mm plywood structural deck
Skypark 5, Suite 1A
45 Finnieston Street,
Timber firrings to Glasgow G3 8JU
TBC
make up roof slope Scotland, UK
norr.com
angle
Drawn Date
LGD 01.08.23
18 mm
Checked Date
40.597 RP 02.08.23
Roof Client
STIRLING COUNCIL
Timber I-Joist truss to Project Name
structural/specalist specifacations BANNOCKBURN ASN
VCL to be fully taped and sealed to walla
and roof VCL to form airtight barrier
T
AF
15mm Durable Plasterboard
Drawing Title
R
VCL Membrane (All joints and junctions to be taped TYPICAL HIGHER PARAPET
D
and sealed to form airtight barrier) DETAIL