Nothing Special   »   [go: up one dir, main page]

Cascade B

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

05195

Revised 03-15-11
Section 40 & 75

Auto-Start/Stop Controller — Cascade


Features
• Durable encapsulated protection against
dirt, water, and dust – rated NEMA4 and
IP65
• Operates during low battery blackouts
• Compatible with Electronic and
Mechanical engines – ECU, MPU,
AC Frequency
• J1939 Ready – Works directly with
MurphyLink J1939 PowerView gages

The Cascade controller offers automatic start and stop control with easy configuration for a broad number of applications.
This auto-start controller is designed to fit any engine-driven application requiring a simple and robust automatic start and
stop sequence. Pumps, Compressors, Grinders, Power Units and Generators are just few of the industrial applications for
the controller.
The Cascade controller is fully compatible with all major engine types. Whether you are running mechanical or J1939
engines, the controller will work with your application.
Here are some of the unique features of the Cascade that only Murphy can offer at our competitive price.
• Durability: Encapsulated to protect it against dirt, water and dust, along with a compression gasket to fully seal it to the
panel. Cascade is rated NEMA4 and IP65.
• Low Battery Blackouts: Operates in total blackout for a minimum of two seconds.
• Compatibility: Accept MPU, AC Frequency and ECU speed signals and can operate with standard and J1939 engines.
• Inputs and Outputs: The Cascade Inputs and Outputs are ruggedly protected and fault tolerant.
• J1939 Ready: Works directly with Murphy’s J1939-ready PowerView gages, just plug and go, no sender is required.
• CD101 Cascade Configuration Tool: Allows quick setup and loading of parameters into a Murphy standard Cascade
via a PC software tool.
Specifications
Power input: 9-35VDC continuous - operates during total black- Outputs: 7 – 4 auxiliary, configurable (1A DC protected). 3 dedi-
out for 2 seconds minimum. cated outputs for Crank, Fuel/ECU, Alternator excitation.
Power consumption: Sleep Mode (Manual): 1mA typical; Sleep Crank attempts: 3, 5, 10, Continuous.
Mode (Automatic): 4mA typical. Running Mode (Manual): Crank Rest: 5-60 seconds, adjustable.
20mA typical; Running Mode (Automatic): 24mA typical. Shutdown lockout time delay: 5, 10, 15, 20, 25, 30 seconds.
Operating/Storage temperature: -40 to 85°C; (-40 to 185°F). Crank disconnect speed setting: Field settable 0-9999 RPM
Humidity: 0-100%, non-condensing. (16-60Hz AC freq input).
Housing: UV stabilized black polycarbonate and epoxy encapsu- Overspeed/underspeed trip point setting: ±5 to 50% of nomi-
lation. Weather tight and includes sealing gasket to keep nal.
moisture and debris out of enclosure. Properly mounted con- Speed sensing inputs: Magnetic pickup (5-120VAC RMS / 0-10
troller will maintain NEMA4 / IP65 rating of enclosure. kHz) & AC frequency (30-600VAC RMS / 16-80 Hz).
Vibration: Rated to 6G. CANbus interface: Directly reads engine speed, & engine status
Impact: Rated to 10G. data* from SAE-J1939 enabled engines.
Inputs: Dedicated digital inputs for low oil pressure, high engine MODbus interface: In J1939 applications drives PVA series
temperature, remote start, DC charge fail/Alternator fail. Two analog gages.
aux inputs are configurable for multiple functions.

*Engine status data limited to low oil pressure, high engine temperature, “Wait to start” status, Warning & Fault lamp information, and communication
error.
Cascade Auto-Start Controller Dimensions

Front View Back View

How to Order
To Order specify: CD101 P/N 40700259
Shipping Weight: 1 lb. (453 g) approximately.
Shipping Dimensions: 5.1 x 6.7 x 1.6 inch (130 x 170 x 41 mm) approx.

Accessories
CD101 Cascade Configuration Kit P/N:40090045