Sai Apartment
Sai Apartment
Sai Apartment
DIPOLOG CITY
CITY/MUNICIPALITY
LAND USE AND ZONING
ARCHITECTURAL
STRUCTURAL
SANITARY
1 PERPSPECTIVE
8 A0 nts
ELECTRICAL
G
OLO
DIP
TO
5
3 MECHANICAL
7 4
6 ALLIE
DM
CEN EDICAL
Y
1
CIT
TER
GA
AN
DIPO
LOG
BO
CITY
TECHNICAL DESCRIPTION SPO
RTS GEODITIC ENGINEER
ZAM
LINE BEARING DISTANCE 2 COM
PLEX
TO
1-2 S21-50W 16.00
2-3 N75-21W 105.00
3-4 S21-50W 4.00
4-5 N75-21W 20.90
5-6 S21-50W 8.00
6-7 N75-21W 12.15 FIRE PROTECTION
7-8 N21-51E 28.02
8-1 S75-21E 138.03
2 SITE DEVELOPMENT PLAN 3 LOCATION MAP
A0 nts A0 nts
SEAL: CIVIL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
1500 2000
1075
1075
W2 D1 D1 W2 D1 W2
1 1
1500
5000
DINING AREA DINING AREA DINING AREA
2 2
A5 A5
2 W1 D1 D1 W1 D1 W1
2
2000
2000
A3
A4
3
2
10500 10500
SEAL: CIVIL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
D C B A 2 1
SEAL: CIVIL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
600
1200 5000 2000
1200
1200
2100
2100
2100
D1 D2 D2 W1 W2 W2
WOODEN PANEL DOOR WOODEN PANEL DOOR PVC HOLLOW CORE DOOR ALUMINUM FRAME AWNING GLASS WINDOW AWNING GLASS WINDOW
(900 X 2100) (800 X 2100) (700 X 2100) SLIDING GLASS WINDOW (600 X 600) (600 X 600)
MAIN DOOR EXIT DOOR BATHROOM DOOR (1200 X 1200) KITCHEN WINDOW BATHROOM
FRONT/SIDE WINDOW
SEAL: CIVIL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
12
1 50
82
2
20
175
1 ROOF PLAN
A4 Scale 1:100
SEAL: CIVIL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
SEAL: CIVIL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
NOTE :
NOTE :
1 STANDARD DETAILS
S2 nts
SEAL: CIVIL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
NOTE :
1 STANDARD DETAILS
S3 nts
SEAL: CIVIL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
PURLINS
KING POST
1000 TOP CHORD
700
BOTTOM
CHORD
A 3500
B 3500
C 3500
D 3500
E 3500
F
1200
1
5000
8200
2
2000
SEAL: CIVIL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
ROOF FRAMING
BEAMS
TIE BEAM
1 STRUCTURAL PLAN
S5 nts
SEAL: CIVIL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
5 COLUMN ELEVATION
S6 Scale: 1 : 40
NOTE :
SEAL: CIVIL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
KS WC WC KS KS WC WC KS KS WC
F F F F F
1 WATERLINE LAYOUT
P1 Scale: 1 : 100
2 SEWERAGE LAYOUT
P1 Scale: 1 : 100
SEAL: MASTER PLUMBER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
2.
PHILIPPINES AND LOCAL REGULATIONS AND ORDINANCES.
ALL PIPES SHALL BE INSTALLED AS INDICATED IN THE
PLAN
WORKING DRAWINGS. ANY RELOCATION REQUIRED FOR
PROPER EXECUTION OF OTHER TRADES SHALL BE UPON
THE APPROVAL OF THE SANITARY ENGINEER.
3. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER
SCALED DIMENSIONS.
4. ALL PIPES SHALL BE PROVIDED W/ PROPER HANGER AND
5.
SUPPORT
ALL FIXTURES SHALL BE VENTED INDIVIDUALLY AND
SPOT DETAIL
WATERLINES SHALL BE VALVE BY GROUP
6. UNLESS OTHERWISE SPECIFIED, ALL PLUMBING FIXTURES
SHALL BE PROPERLY VENTED. MAXIMUM DISTANCE OF
VENTILATION FROM FIXTURES SHALL BE 1.50 m MEASURED
ALONG THE LENGTH OF PIPE.
7. ALL PLUMBING FITTINGS SHALL BE ACCESSIBLE FOR
MAINTENANCE. PROVIDE MANHOLE IF SUCH SECTION
INSTALLATIONS ARE INSIDE THE CEILING.
8. ALL CHANGES IN DIRECTIONS SHALL BE MADE BY THE
APPROPRIATE USE OF FORTY FIVE (45) WYE LONG SWEEP FFL
QUARTER BEND. ONE EIGHT WHEN THE CHANGE OF FLOW
IS FROM HORIZONTAL TO VERTICAL A SINGLE BEND
COMBINATION MAY BE USED ONLY ON VENT PIPE.
9. NO DOUBLE HUB OR DOUBLE TEE BRANCH SHALL BE USED
ON HORIZONTAL SOIL OR WASTE LINES.
10. PROVIDE PIPE SLEEVES AT WALL, COLUMNS OR SLAB TO
PROTECT FROM BREAKAGE. 2 ROOF DRAIN DETAIL
11. ALL EXPOSED PIPINGS AND FITTINGS IN THE AREAS SHALL
BE CHROME PLATED.
AIR CHAMBER DETAIL P2 nts
12. THE BRAND AND OTHER DETAILED PLUMBING FIXTURES 1 SECTION
SHALL BE IN ACCORDANCE WITH THE SCHEDULE
FURNISHED BY THE ARCHITECT. P2 nts
13. GATE VALVE SHALL BE BRONZE BODY, SOLID WEDGE
14.
TYPE, SCREWED OR FLANGE END. 3 CLEAN-OUT DETAIL
USE POLYPROPYLENE RANDOM,TYPE 3,PN20 FOR ALL
15.
WATER PIPING SYSTEM.
USE uPVC SANITARY PIPING SYSTEM SERIES 1000 FOR 100
P2 nts
LEGEND:
WATER DISTRIBUTION SYSTEM
WATERLINE
FIRELINE
PLAN
GV GATE VALVE
FV FLOAT VALVE
WSP WET STAND PIPE
DSP DRY STAND PIPE
FHC FIRE HOSE CABINET FFL
BI BLACK IRON PIPE
WASTE, SEWER & VENT SYSTEM
SANITARY LINE
VENT LINE
FCO FLOOR CLEAN-OUT
FD SHOWER/FLOOR DRAIN
VS VENT STACK PLAN
SS SOIL STACK
VAC VENT ACROSS CEILING
VP VENT PIPE
PVC POLYVINYL CHLORIDE SECTION
WP WET PIPE
SP SOIL PIPE
VTR VENT THRU ROOF
SCHEDULE OF DIMENSIONS
ST SEPTIC TANK
PIPE DIMENSION IN MM
AC AIR CHAMBER SIZE IN
'A' D F
WASTE, SEWER & VENT SYSTEM
DRAINAGE LINE 50 100x100 225.42
SLOPE = 1/10 SLOPE = 1/10
SECTION
75 125x125 225.42
DS DOWNSPOUT
100 150x150 225.42
CB CATCH BASIN 150 200x200 282.57
RD ROOF DRAIN
CD CORRIDOR DRAIN
PLUMBING FIXTURES
LAV LAVATORY
WC WATER CLOSET
EWT ELEVATED WATER TANK
DIMENSION (in meters)
4 TYP. SEPTIC TANK DETAILS 5 FLOOR DRAIN DETAIL
L W H Lc
P2 nts P2 nts
3.00 2.00 1.20 1.20
SEAL: MASTER PLUMBER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
S S S S S S
S S S
1 LIGHTING LAYOUT
E1 Scale: 1 : 100
LP LP LP
6 7 8
2 POWER LAYOUT
E1 Scale: 1 : 100
SEAL: PROFESSIONAL ELECTRICAL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>
SPARE
SPARE
2 LOAD SCHEDULE
3 SINGLE-LINE DIAGRAM
E2 nts
E2 nts
SEAL: PROFESSIONAL ELECTRICAL ENGINEER: PROJECT: APPROVED BY: SHEET CONTENT: DRAWN BY: <DRAWNBY> DRAWING NO.:
PROPOSED CONSTRUCTION OF 3 UNITS ONE (1) DATE: <DATEDRAWN>