Nothing Special   »   [go: up one dir, main page]

CO Conductimetre Humeau 8 80

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Bench meters

COND 8+
COND - TDS - Salinity - Temperature
GLP - USB Data Logger - RS232 printer

COND 80+
COND - TDS - Salinity - Resistivity - Temperature
GLP - GMP - USB Data Logger - RS232 printer

makes Conductivity easy

MADE IN ITALY
Easy is the name of the game
GiorgioBormac company, expert in electrochemistry, has developed this new line of bench meters, finding the
correct equilibrium between design and simplicity of use. Simple to use.
The wide color display, simple to read, shows all the necessary informations, like the measure, the buffer
solutions used in the last calibration, the cell constant, GLP informations and the memorized data.
Multilanguage interface that supports English, Spanish, French, German, Italian, Czech… up to 8 languages.
Using only 5 keys, the user has the complete control of all the functions. Simple to understand.
Up to 4 conductivity calibration points, with automatic recognition of the buffer solutions, standards or defined
by the user.
Support to calibration through icons with an advance diagnosis of the conditions of the cell. Saving calibration
for each cell constant. Simple to calibrate.

COND 8+
COND - TDS - Salinity - Temperature - GLP - Data Logger
Main features
• Automatic calibration 1 to 4 points, between 4 conductivity standard values
• Simultaneous display of COND/TDS/Salinity and temperature
• Resolution: automatic scale
• Selectable cell constant allows for use with 2 plates cell
• Saving and recall calibration for each cell constant
• Numeric password for calibration management and data memory delete
• Manual calibration on 1 point (User defined)
• Automatic and Manual temperature compensation, reference values 15…30 °C
• Large color display with indication of calibration standard solutions used and measurement’s stability
• Stability indication, with icon
• Memory recall of last calibration, date and time, and informations about the cell constant
• Calibration Timer: set frequency of the calibration for high quality of measurements
• Non-volatile memory holds up to 1000 data , with date and time, automatically (Data logger)
or manually, and downloadable on PC with free software “DataLink”or printable
• Stirrer plate included (in stirrer version)
• Multilanguage menu setup
• 3 years warranty

2 COND 8+ Basic Back panel COND 8+


Bench meters

COND 8+ Stirrer

Setup menu Measurement screen

How to order COND 8+


Code Description
COND 8+ kit STIRRER with conductivity cell 2301T, conductivity standards 1413 µS and 12,88 mS, 2 beckers with magnetic bar, electrode holder and
50003232
accessories. With stirrer
50003242 COND 8+ kit STIRRER without conductivity cell, includes conductivity standards 1413 µS and 12,88 mS, electrode holder and accessories. With stirrer

50003202 COND 8+ kit BASIC with conductivity cell 2301T, conductivity standards 1413 µS and 12,88 mS, electrode holder and accessories. Without stirrer

50003212 COND 8+ kit BASIC without conductivity cell, includes conductivity standards 1413 µS and 12,88 mS, electrode holder and accessories. Without stirrer

50001132 Magnetic stirrer, controlled by the meter

50003352 VPT 1 conductivity cell C=1 with ATC, glass body, platinum plate, cable length 1m . Measuring range 10 µS…100 mS, 0…80°C

50004002 2301T conductivty cell with ATC, C=1, range 10 µS…100 mS, 0…60°C

50004012 VPT 01 conductivty cell C=0,1 with ATC, PVC/ steel, cable length 1m. Measuring range 0,1 µS…1 mS, 0…60°C

50004072 VPT 10 conductivty cell, C=10, with ATC, cable length 1m, measuring range 100 µS…200 mS

50002012 NT 55 temperature probe

50001502 RS232 printer, normal paper, for series 8+ - 80+

50001512 Power supply AC/DC 12 V/1A for series 8+ - 80+

3
COND 80+
COND - TDS - Salinity - Resistivity - Temperature - GLP - GMP - Data Logger

Main features
• Simultaneous display of COND/TDS/Salinity/Resistivity
and temperature
• Resolution: automatic scale - Selectable cell constant allows Cond calibration procedure
to use with 2 plates cell
• Alphanumeric password for calibration management
and data memory delete with soft keypad included
• GLP and IQ-OQ manual available
• Saving and recall calibration for each cell constant
• Automatic calibration from 1 to 4 calibration points,
between 4 standard buffer solutions
• Manual calibration on 1 point (defined by the user)
• Wide colored display with indication of calibration
standards solutions used and measurement’s stability
• Automatic and manual temperature compensation,
reference values 15…30°C
• Compensation for Ultrapure water for low conductivity measurement
• Memory recall of last calibration, date, time and informations
about the cell constant
• Calibration Timer: set frequency of the calibration for high quality
of measurements
• Indication of stability
• Non-volatile memory holds up to 1000 data , with date and time,
automatically (Data logger) or manually, and downloadable
on PC with free software “DataLink”or printable
• Stirrer plate included (in stirrer version)
• 2 USB ports, for PC connection, and for external keyboard included
• RS232 port for printer connection
• Multilanguage menu setup
• Quick on-line manual
• 3 years warranty

RS232 printer VPT 01


Back panel COND 80+ for COND 8+ e COND 80+ for ultra pure water

4
Bench meters

NOT
LINEAR
Ultrapure Water
temperature compensation

COND 80+ Stirrer

Setup menu Measurement screen

How to order COND 80+


Code Description
COND 80+ kit STIRRER with glass conductivity cell VPT 80/1, conductivity standard solutions 1413 μS and 12,88 mS, soft keypad, power supply and
50003402
acessories. With stirrer
COND 80+ kit STIRRER without conductivity cell, includes conductivity standard solutions 1413 μS and 12,88 mS, soft keypad, power supply and
50003412
acessories. With stirrer
COND 80+ kit BASIC with glass conductivity cell VPT 80/1, conductivity standard solutions 1413 μS and 12,88 mS, soft keypad, power supply and
50003422
acessories. Without stirrer
COND 80+ kit BASIC without conductivity cell, includes conductivity standard solutions 1413 μS and 12,88 mS, soft keypad, power supply and
50003432
acessories. Without stirrer
50003352 VPT 1 conductivity cell C=1 with ATC, glass body, platinum plates, cable length 1m. Measuring range 10 μS…100 mS, 0…80°C

50004072 VPT 10 conductivity cell C=10 with ATC, cable length 1m. Measuring range 100 µS…200 mS

50004012 VPT 01 conductivity cell C=0,1 with ATC, PVC/ steel, cable length 1m. Measuring range 0,1 μS…1 mS, 0…60°C

50002012 NT 55 temperature probe

50001462 External USB keyboard

50001502 RS232 Printer, normal paper for series 8+ - 80+

50001512 Power supply AC/DC 12 V/1A for series 8+ - 80+

50001472 IQ-OQ Manual

5
XS Conductivity Cells
Shaft Material: Glass BNC Plug
Temperature probe: No/Yes (on VPT 80/1)
Plates: Platinum
Length: 120 mm
Diameter: 12 mm RCA Cinch Plug

Model Range COND Temp. °C Connection Note Code


VP 1 10 μS…10 mS 0…+80 °C Fix cable / BNC Cell constant C=1 50004062
Cell constant C=1
VPT 1 10 μS…10 mS 0…+80 °C Fix cable / BNC temperature probe NTC 30KΩ 50003352
RCA Cinch plug

Shaft Materiale: PVC / Steel


Temperature probe Yes
Plates: Steel
Length: 120 mm
Diameter: 12 mm

Model Range COND Temp. °C Head Note Code


Cell constant C=0,1 , Temp. probe
VPT 01 0,1μS…1mS 0…+60 °C Fix cable / BNC NTC 30KΩ plug RCA Cinch 50004012
for ultra pure water

Shaft Material: Glass


Temperature probe: Yes
Plates: Platinum
Length: 120 mm
Diameter: 12 mm

Model Range COND Temp. °C Head Note Code


Cell constant C=10 , temp. probe
VPT 10 100 μS…200 mS 0…+80 °C Fix cable / BNC NTC 30KΩ plug RCA Cinch 50004072
for sea water

Shaft Material: Epoxy


Temperature probe: Yes
Plates: Platinum
Length: 120 mm
Diameter: 12 mm

Model Range COND Temp. °C Head Note Code


Cell constant C=1 ,
2301T 10 μS…100 mS 0…+60 °C Fix cable / BNC Temp. probe NTC 30KΩ 50004002
plug RCA Cinch

6
Bench meters

Certificated DANAK/DFM

Conductivity standards 5 µS/cm


certificated DANAK/DFM

Conductivity standard 5 µS/cm


NIST traceability

Calibration solutions NIST traceability certificate


Conductivity standards
• Ergonomic bottle, 500 ml, with calibration compartment • 24 months guaranteed lifetime
incorporated , with table of conductivity variation as a • 1,3 and 5,0 µS/cm 12 months guaranteed lifetime
function of temperature, for an accurate calibration • On the certificate are reported real value and expiry date
• 1,3 e 5,0 µS/cm in glass bottle, 300 ml • Certificates of analysis downloadable on website
• Cheaper, just use the necessary for calibration

XS Professional with DANAK/DFM certificate XS Basic with NIST traceability

CONDUCTIVITY STANDARDS CONDUCTIVITY STANDARDS


Code Packaging Value µS/cm (20°C / 25 °C) Accuracy Code Packaging Value µS/cm (20°C / 25°C) Accuracy
51300303 300 ml 1,3 ± 0.1 µS/cm 51100503 300 ml 1,3 ± 0.1 µS/cm
51300313 300 ml 5,0 ± 0.1 µS/cm 51100513 300 ml 5,0 ± 0.1 µS/cm

51300323 500 ml 76 / 84 ± 1% 51100613 500 ml 76 / 84 ± 1%


51300333 500 ml 133 / 147 ± 1% 51100623 500 ml 133 / 147 ± 1%
51300343 500 ml 1278 / 1413 ± 1% 51100633 500 ml 1278 / 1413 ± 1%
51300353 500 ml 11670 / 12880 ± 1% 51100643 500 ml 11670 / 12880 ± 1%

Fill compartment with a simple press Calibrate the elctrode Empty the calibration compartment
7
Datasheet COND 80+ COND 8+
0,00…20,00 - 200,0 - 2000 μS / 2,00 - 20,00 - 0,00…20,00 - 200,0 - 2000 μS / 2,00 - 20,00 -
COND measuring range
200,0 - 1000 mS 200,0 mS
Resolution Automatic scale
Accuracy ±1 % full scale

COND calibration points 1…4


Buffer auto recognition 84, 1413 μS, 12.88, 111.8 mS, 1 defined by the user
Indication of calibration points Yes
Temperature coefficent Ultrapure Water and 0,00…10,00 %/ °C 0,00…10,00 %/ °C
Reference temperature 15…30ºC
GLP calibration Yes, with date and time
Indication of conditions of the cell Yes, with icon
Indication of cell constant Yes
Calibration timer with alarm Yes
Cell type 2 poles
Cell constant 0,1 - 1 - 10
TDS measuring range 0,1 mg/l…500g/l 0,1 mg/l…100g/l
TDS Factor/ Accuracy 0.40 … 1.00 / ±1 % full scale
Salinity measuring range / Accuracy 0,01…100 ppt / ±1 % full scale
Resistivity measuring range / Accuracy 1…10 MΩ / ±1 % full scale —
Temperature °C measuring range / Accuracy -20,0…120,0 / ± 0,5°C -10…110,0 / ± 0,5°C
Temperature compensation Automaric or Manual 0…100°C (NTC 30KΩ)
Temperature calibration Yes

GLP system Yes


Password Yes, alphanumeric Yes, numeric
Memory MAN/AUTO 1000 data, with date and time
Display Multicolor dot matrix, with icons, digital view
BNC, Cinch/RCA (ATC), RS232 for printer, USB for BNC, Cinch/RCA (ATC), RS232 for printer, USB for
Input
PC and USB for external keyboard PC connection
Selectable languages 8 languages
On-line manual Yes —
Magnetic stirrer Yes
Speed control 0…3000 rpm
IP protection IP 54
Power supply AC/DC adaptor 12V / 1000mA
Dimensions 165 x 195 x 68 mm
Weight 1050 g (without stirrer)

COND 8+-COND 80+ 12-17 VER 2.0 ENG