CENTAX-L

Assembly and operating instructions


016L-00050…00090-SS/FS/FF20
M016-00004-EN
Rev. 2
Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

Contents

1 General remarks ..................................................................................... 5

2 Safety ..................................................................................................... 6
2.1 Safety remarks .................................................................................. 6
2.1.1 Signal words ......................................................................... 6
2.1.2 Pictograms ............................................................................ 7
2.2 Qualification of deployed personnel ...................................................... 7
2.3 Intended application........................................................................... 7
2.4 Application not in compliance with the intended use ............................... 9

3 Delivery, transport, storage and disposal ............................................. 10


3.1 Delivery ...........................................................................................10
3.2 Transport .........................................................................................10
3.3 Storage ...........................................................................................10
3.3.1 Storage location....................................................................11
3.3.2 Storage of couplings / flexible elements ...................................11
3.4 Disposal...........................................................................................11

4 Technical description ............................................................................ 12


4.1 Characteristics..................................................................................12
4.2 Specifications ...................................................................................12

5 Alignment of the units being connected ................................................ 13


5.1 Axial alignment.................................................................................14
5.2 Radial alignment ...............................................................................15
5.3 Angular alignment.............................................................................17

6 Mounting .............................................................................................. 18
6.1 General assembly instructions ............................................................18
6.2 Mounting overview ............................................................................20
6.3 Mounting the hub for link/flange hub (3)..............................................22
6.3.1 Mounting the hub for link (3) with cylindrical bore and keyway ...22
6.3.2 Mounting the hub for link (3) with conical oil interference fit .......24
6.3.3 Mounting the flange hub (3) ...................................................27
6.4 Mounting the hub/adapter (4) ............................................................28
6.4.1 Mounting the hub (4) with cylindrical bore and keyway ..............28
6.4.2 Mounting the hub (4) with conical oil interference fit .................30
6.4.3 Mounting the adapter (4) .......................................................33
6.5 Aligning the units ..............................................................................33
6.6 Positioning the link flange assembly ....................................................34
6.7 Mounting the centrifugal protection (D/F) assembly ..............................35
6.7.1 Mounting the centrifugal protection assembly (D),
sizes 00050…00080 and 00082…00090 ....................................36
6.7.2 Mounting the centrifugal protection assembly (F), size 00081 .....37

CENTA Antriebe Kirschey GmbH 2 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.8 Connecting the rubber elements .........................................................38


6.9 Removing the mounting supports........................................................40
6.10 Mounting the links ............................................................................40
6.11 After completed mounting ..................................................................43

7 Operation.............................................................................................. 44
7.1 Operating faults, root causes and remedy ............................................44
7.2 Admissible overall misalignment of the coupling ...................................44

8 Care and maintenance .......................................................................... 45


8.1 Work to be performed .......................................................................45
8.1.1 Cleaning the coupling ............................................................45
8.1.2 Visual inspection of the coupling .............................................45
8.1.3 Visual inspection of links ........................................................45
8.1.4 Visual inspection of the rubber elements / rubber segments .......46
8.1.5 Inspection of the screw connections ........................................46
8.2 Replacing defective parts ...................................................................46

9 Dismantling .......................................................................................... 47
9.1 General dismantling instructions .........................................................47
9.2 Dismantling the links .........................................................................48
9.3 Disconnecting the rubber elements .....................................................48
9.4 Dismantling the centrifugal protection assembly (D/F) ...........................48
9.4.1 Dismantling the centrifugal protection assembly (D),
sizes 00050…00080 and 00082…00090 ....................................48
9.4.2 Dismantling the centrifugal protection assembly (F),
size 00081 ...........................................................................48
9.5 Dismantling the link flange assembly (1) .............................................49
9.6 Removing the mounting supports........................................................49
9.7 Dismantling the hub/adapter (4; if necessary) ......................................49
9.7.1 Dismantling the hub with cylindrical bore and keyway ...............49
9.7.2 Dismantling the hub with conical oil interference fit ...................49
9.7.3 Dismantling the adapter (4) ...................................................50
9.8 Dismantling the hub for link/flange hub (3; if necessary) ........................... 51
9.8.1 Dismantling the hub for link (3) with cylindrical bore and keyway ... 51
9.8.2 Dismantling the hub for link (3) with conical oil interference fit ....... 51
9.8.3 Dismantling the flange hub (3) ...............................................52
9.9 Reassembling the coupling .................................................................52

10 Wearing and spare parts....................................................................... 53

11 Annex ................................................................................................... 54
11.1 CENTA data sheet D013-013 (lubricated screw connections) ..................54
11.2 CENTA data sheet D016-900 Declaration of incorporation according to
the EC Machinery Directive 2006/42/EC, Appendix II B ..........................55

CENTA Antriebe Kirschey GmbH 3 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

Index of illustrations
Fig. 5-1 Axial misalignment ........................................................................ 14
Fig. 5-2 Radial misalignment ...................................................................... 15
Fig. 5-3 Angular misalignment .................................................................... 17
Fig. 6-1 Example: 016L-00050…00080 and 00082…00090-..20 ...................... 20
Fig. 6-2 Example: 016L-00081-..20 ............................................................ 20
Fig. 6-3 Mounting the hub for link (3) with cylindrical bore and keyway ........... 22
Fig. 6-4 Mounting the hub for link (3) with conical oil interference fit .............. 24
Fig. 6-5 Mounting the flange hub (3) ........................................................... 27
Fig. 6-6 Mounting the hub (4) with cylindrical bore and keyway ...................... 28
Fig. 6-7 Mounting the hub (4) with conical oil interference fit ......................... 30
Fig. 6-8 Mounting the adapter (4) ............................................................... 33
Fig. 6-9 Positioning the link flange assembly ................................................ 34
Fig. 6-10 Mounting the centrifugal protection assembly (D)............................ 36
Fig. 6-11 Mounting the centrifugal protection assembly (F) ............................ 37
Fig. 6-12 Connecting the rubber elements ................................................... 38
Fig. 6-13 Detail X ..................................................................................... 38
Fig. 6-14 Mounting the links ("ccw" counterclockwise rotation) ....................... 41
Fig. 6-15 Mounting the links ("cw" clockwise rotation) ................................... 41

Index of tables
Table 2-1 Shape and size of ventilation holes ................................................ 8
Table 5-1 Permissible radial alignment tolerance .......................................... 16
Table 6-1 Guide to links............................................................................. 40
Table 7-1 Troubleshooting table ................................................................. 44

Index of formulas
Formula 5-1 Calculated dimension SW.......................................................... 17

CENTA Antriebe Kirschey GmbH 4 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

1 General remarks
These assembly and operating instructions form a constituent part of the
coupling delivery and must be kept in an easily accessible place at all times.

CENTA products are developed and produced to quality standard


DIN EN ISO 9001:2000.

In the interests of further development, CENTA reserves the right to make


technical changes.

IMPORTANT
CENTA is unable to accept liability for damage and operating faults caused by failure to
observe the operating instructions.

These operating instructions are protected under copyright to CENTA Antriebe


Kirschey GmbH.

In case of technical questions, please enquire with our head office:

CENTA Antriebe
Kirschey GmbH
Bergische Strasse 7
42781 Haan
GERMANY
Phone +49-2129-912-0
Fax +49-2129-2790
centa@centa.de
www.centa.info

CENTA Antriebe Kirschey GmbH 5 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

2 Safety
The purpose of these operating instructions is to enable users to:
 use the coupling safely and correctly
 maximize efficiency
 ensure that care and maintenance are carried out correctly

For this reason, these operating instructions must be thoroughly read and
understood prior to work on and with the coupling.

WARNING
Injury and material damage can occur as a result of:
 Failure to adhere to the safety and accident prevention regulations
valid at the relevant installation site
The safety and accident prevention regulations valid at the installation
site in question must be adhered to when performing any of the tasks
described in these operating instructions.

2.1 Safety remarks


In these operating instructions, safety remarks are indicated by a pictogram and
a signal word.

2.1.1 Signal words


The following signal words are used in the safety remarks:

Denotes the immediate threat of danger.


DANGER If not prevented, fatal or extremely serious injuries can result.

Denotes a potentially dangerous situation.


WARNING If not prevented, fatal or extremely serious injuries can result.

Denotes a potentially dangerous situation.


CAUTION If not prevented, minor injuries and/damage to property may result.

Denotes application tips and particularly useful information. This is not


IMPORTANT a signal word denoting a dangerous or damaging situation.

CENTA Antriebe Kirschey GmbH 6 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

2.1.2 Pictograms
Possible pictograms in the safety precautions:

Warning of a hazardous area

Do not switch

Use protective gloves

Use protective goggles

2.2 Qualification of deployed personnel


All the work described in these operating instructions may only be performed by
authorized persons with adequate training and instruction.

WARNING
Injury and material damage can occur as a result of:
 Work at the coupling which is not described in these instructions
Only carry out work which is described in these operating instructions.

2.3 Intended application

WARNING
Injury and material damage can occur as a result of:
 Application not in compliance with the intended use
The couplings are intended exclusively for use in accordance with the
relevant design. They may only be used under the specified conditions.

CENTA Antriebe Kirschey GmbH 7 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

WARNING
Injuries can occur as a result of:
 Contact with rotating parts
Shield the coupling in accordance with the applicable accident
prevention regulations with an enclosure.
Exception:
The coupling is encased by the driving and driven units.

The scope of delivery provided by CENTA does not include a protective


enclosure.

This enclosure must fulfil the following criteria:


 Provide protection against persons gaining access to rotating parts
 Restrain any rotating parts which may be work loose
 Guarantee sufficient ventilation for the coupling

This enclosure must be made of stable steel components. In order to ensure


adequate ventilation for the coupling, the enclosure must be fitted with regular
openings. For safety reasons, these openings must not exceed the dimensions
outlined in table 2-1.

Component Circular openings Rectangular openings


[mm] [mm]

Top of the enclosure Ø8 8

Side elements of the Ø8 8


enclosure

Table 2-1 Shape and size of ventilation holes

The enclosures must be positioned a minimum of 15 mm distant from rotating


parts. The enclosure must be electrically conductive and be included in the
equipotential bonding.

Before commencing long-term operation, the plant must successfully complete a


test run.

CENTA Antriebe Kirschey GmbH 8 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

2.4 Application not in compliance with the intended use

WARNING
Injury and material damage can occur as a result of:
 Inadmissibly high torque
 Inadmissibly high or low speeds
 Exceeding the specified ambient temperature
 Inadmissible ambient medium
 Inadmissible coupling enclosure
 Exceeding the admissible overall misalignment values
Only use the coupling for the specified application.

CENTA bears no liability for damage resulting from application not in compliance
with the intended use of the equipment.
Should there be a change of plant parameters, the coupling design must be
reviewed by CENTA (address see chapter 1).

CENTA Antriebe Kirschey GmbH 9 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

3 Delivery, transport, storage and disposal


3.1 Delivery
After delivery, the coupling:
 must be checked for completeness and correctness of the delivery.
 must be examined for possible transport damage (which must be reported
immediately to the carrier).

3.2 Transport

CAUTION
Injury and material damage can occur as a result of:
 Incorrect transportation of couplings
Ensure that the coupling is correctly transported.

CAUTION
Material damage to coupling components can occur as a result
of:
 Contact with sharp-edged objects
Protect coupling components for transportation.
Only hoist coupling components with nylon belts or ropes.
Always cushion parts when supporting them from below.

Following transportation damage:


 Check the coupling carefully for damage.
 Consult the manufacturer (Address see chapter 1).

3.3 Storage

CAUTION
Material damage to elastic elements and rubber parts can occur
as a result of:
 Incorrect storage
These parts must be stored laid flat and so they cannot distort, and
protected from ozone, heat, light, moisture and solvents.

IMPORTANT
Rubber parts are marked where possible with their production date. From this date,
they may only be stored for a maximum of 5 years.

CENTA Antriebe Kirschey GmbH 10 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

3.3.1 Storage location


Requirements imposed on the storage location:
 Moderately ventilated and low in dust
 Dry (max. 65% humidity)
 Temperature stabilized (-10°C to +25°C)
 Free of ozone-producing devices such as light sources and electric motors
 Free of UV light sources and direct sunlight
 Do not store solvents and disinfectants, fuels or lubricants, acids, chemicals
etc. in the same location

For more details, refer to DIN 7716.

3.3.2 Storage of couplings / flexible elements


 Unpack the parts.
 Check the packaging for damage. Replace if necessary.
 Check that the wax protection on steel components is intact. If necessary,
patch or renew.
 Package the parts (for prolonged periods of storage, enclose desiccant and
weld into film).
 Place the parts into storage.

3.4 Disposal

RECYCLING
Ensure safe, environmentally responsible disposal of operating supplies
and exchange parts. For this, locally provided recycling facilities and
regulations must be utilized.

For disposal, the coupling parts must be separated where possible and sorted
according to material type.

CENTA Antriebe Kirschey GmbH 11 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

4 Technical description
4.1 Characteristics
The CENTAX-SEC series L coupling have the following excellent characteristics,
due to the combination of a torsionally flexible CENTAX element and the CENTA
link coupling with axial angular movement:

 Compensation of torsional vibrations and impacts without wear.


 Compensation of major axial, radial and angular displacement with minimal
restoring forces.
 Silent operation and noise damping.
 Backlash free, torsionally rigid and radially rigid.
 Low-maintenance, free of wear.
 Easy visual inspection.
 Fast exchange of components.
 No special tools required.
 The design is protected by international patents.
 Type approval from leading classification agencies.
 Tried and tested thousands of times over in tough daily operation since 1992.

4.2 Specifications
The specifications can be found in the catalogue and the dimensions in the
installation drawing.

CENTA Antriebe Kirschey GmbH 12 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

5 Alignment of the units being connected

IMPORTANT
 Align the units during the assembly.
 Align the units that are to be connected as accurately as possible. In this way, a
long service life for the coupling and maximum operating misalignment values can
be achieved.
The overall misalignment is composed of the misalignment and the operating
misalignment. The permissible overall misalignment values can be found in the
corresponding catalogue and must not be exceeded.
 All permissible alignment tolerances apply to arrangements at operating
temperatures.
If the arrangement would be aligned at a different temperature, there would be
additional deviations in the arrangement, which were produced by the difference
between the aligning and operating temperature.
For alignment, this has to be taken into account.
 After completion of assembly, check the alignment of the coupling again and if
necessary correct.

CENTA Antriebe Kirschey GmbH 13 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

5.1 Axial alignment


Determine the axial misalignment (see Fig. 5-1).

 Take installation length L from the installation drawing.


 Align the units (installation dimension = L±∆KA max).

Permissible axial alignment tolerance:


∆KA max=0.5 mm

Fig. 5-1 Axial misalignment

CENTA Antriebe Kirschey GmbH 14 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

5.2 Radial alignment

CAUTION
Material damage to elastically installed engines can occur as a
result of:
 Disregard to which extent the engine mounts may settle during
alignment
During vertical alignment, take into account the extent by which the
engine mounts settle. Please enquire about specifications for the
degree of settling from the engine manufacturer or engine mounts
manufacturer.

Measure the radial misalignment with a dial gauge (see Fig. 5-2).

 Attach the dial gauge to the hub.


 Set the sensor of the dial gauge radially against the centering.
 Turn the hub with dial gauge and hub slowly by 360°.
 Align the units (calculated deviation ≤∆KR max).

The permissible radial alignment tolerance ∆KR max can be found in the following
table.

Fig. 5-2 Radial misalignment

CENTA Antriebe Kirschey GmbH 15 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

Size Shorehardeness ∆KR max


[Shore A] [mm]

50 - 56 45 / 50 / 60 ±0.9

70 ±0.3

64, 65, 67 50 / 60 ±0.9

70 ±0.3

66, 69 - 71 50 / 60 ±1.2

70 ±0.36

72 50 / 60 ±1.5

70 ±0.45

75 50 / 60 ±1.65

70 ±0.51

78 50 / 60 ±1.8

70 ±0.6

80 50 / 60 ±2.1

70 ±0.66

81 50 / 60 ±2.1

70 ±0.75

82 - 90 50 / 60 ±2.4

70 ±0.75

Table 5-1 Permissible radial alignment tolerance

CENTA Antriebe Kirschey GmbH 16 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

5.3 Angular alignment


Measure the angular misalignment with a dial gauge (see Fig. 5-3).

 Attach the dial gauge to the hub.


 Position the sensor of the dial gauge radially against flat surface at a
distance R.
 Turn the hub with dial gauge and hub slowly by 360°.

The maximum dial gauge deflection must not exceed the value 2xSw at any
point. The permissible tolerance SW max should be calculated according to formula
below.

 Align the units (calculated deviation ≤∆KW max).

Permissible angular alignment tolerance:


∆KW max=0.15°

Fig. 5-3 Angular misalignment

Formula 5-1 Calculated dimension SW

CENTA Antriebe Kirschey GmbH 17 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6 Mounting
6.1 General assembly instructions
Any work method which impairs the safety of the coupling is prohibited.
The user undertakes to notify the manufacturer immediately of any changes
occurring at the coupling which could impair safety (address see chapter 1).

WARNING
Injuries can occur as a result of:
 Contact with rotating parts
Before starting work at the coupling, switch off the plant and secure
against unintentional start-up.

WARNING
Injury and material damage can occur as a result of:
 Assembly of the coupling in the wrong sequence
Only ever assemble the coupling in the described sequence.

WARNING
Injury and material damage can occur as a result of:
 Falling coupling components
Secure coupling components against falling to the floor.

CAUTION
Material damage to coupling components can occur as a result
of:
 Contact with sharp-edged objects
Protect coupling components for transportation.
Only hoist coupling components with nylon belts or ropes.
Always cushion parts when supporting them from below.

CAUTION
Material damage can occur as a result of:
 Soiled joint surfaces
The surfaces that are to be joined must be free of dirt, preservatives
and lubricants.

CENTA Antriebe Kirschey GmbH 18 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

CAUTION
Material damage to coupling components can occur as a result
of:
 Anaerobic adhesives (e.g. Loctite) used for screw locking
This type of screw locking medium may not be in contact with rubber
parts.

IMPORTANT
 Screw preparation and tightening torque levels in accordance with
CENTA data sheet D013-013 (see chapter 11.1).
 Use suitable lifting devices for assembly.
 The following assembly stages are described for coupling 016L-000..-SS/FS/FF20.
 Part illustration and marking may different slightly from installation drawing and
delivery state.

CENTA Antriebe Kirschey GmbH 19 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.2 Mounting overview


The following figures are showing examples of possible design.

Fig. 6-1 Example: 016L-00050…00080 and 00082…00090-..20

Fig. 6-2 Example: 016L-00081-..20

CENTA Antriebe Kirschey GmbH 20 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

Item Info Designation Remark

1 Link flange assembly Pre-mounted by CENTA

1.1 Rubber element

1.2 Link flange

2 Link See installation drawing for


the direction of rotation
“cw/ccw“

3 Hub for link/Flange hub Scope of supply see


installation drawing

4 Hub/Adapter Scope of supply see


installation drawing

5.1 Rubber element

5.2 Ring

11 Ring Scope of supply of sizes


-00050…00080 and
-00082…00090

13 Ring Scope of supply of size


-00081

D Centrifugal protection assembly Pre-mounted by CENTA;


Scope of supply of sizes
-00050…00080 and
-00082…00090

F Centrifugal protection assembly Pre-mounted by CENTA;


Scope of supply of size
-00081

 Mount the coupling as appropriate for the supplied design, according to the
sequence described below. For supplied design and the parts built-in, see
installation drawing.
 Mounting the hub for link/flange hub (3), see chapter 6.3 .
 Mounting the hub/adapter (4), see chapter 6.4 .
 Aligning the units, see chapter 5 .
 Positioning the link flange assembly (1), see chapter 6.6 .
 Mounting the centrifugal protection assembly (D/F), see chapter 6.7 .
 Mounting the rubber elements (1.1 and 5.1), see chapter 6.8 .
 Removing the mounting supports, see chapter 6.9 .
 Mounting the links (2), see chapter 6.10 .
 After completed mounting, see chapter 6.11 .

CENTA Antriebe Kirschey GmbH 21 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.3 Mounting the hub for link/flange hub (3)


 Mount the hub for link/flange hub (3) as appropriate for the type supplied
(see installation drawing):
 Mounting the hub for link (3) with cylindrical bore and keyway,
see chapter 6.3.1 .
 Mounting the hub for link (3) with conical oil interference fit,
see chapter 6.3.2 .
 Mounting the flange hub (3), see chapter 6.3.3 .

6.3.1 Mounting the hub for link (3) with cylindrical bore and keyway

Fig. 6-3 Mounting the hub for link (3) with cylindrical bore and keyway

Item Info Designation Remark

3 Hub for link

A Shaft Customer part

a Face of shaft

b Face of hub for link

CENTA Antriebe Kirschey GmbH 22 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

CAUTION
Material damage can occur as a result of:
 Incorrect heating of the hubs/flange hubs
Heat the hubs/flange hubs steadily in an oil bath, a fan oven, on an
electric hot plate, either inductive or with a flame (ring burner).

CAUTION
Injuries can occur as a result of:
 Hot coupling components
Use suitable protective gloves.

 Warm the hub for link (3) to a temperature of 170° - 200°C.


 Push the hub for link (3) onto the shaft (A).

IMPORTANT
Face of shaft must not protrude to face of hub. Otherwise radial replacement of other
coupling parts is not guaranteed.

CAUTION
Material damage can occur as a result of:
 Hot hubs/flange hubs
Before further mounting of hubs/flange hubs, allow them to cool to
ambient temperature.

CENTA Antriebe Kirschey GmbH 23 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.3.2 Mounting the hub for link (3) with conical oil interference fit

Fig. 6-4 Mounting the hub for link (3) with conical oil interference fit

Item Info Designation Remark

3 Hub for link

19 Screw plug G¼ or G¾
see installation drawing

A Shaft Customer part

a Face of shaft

b Face of hub for link

c Thread G¼ or G¾
see installation drawing

 Lightly oil the cone of the shaft (A).


 Push the hub for link (3) onto the shaft (A).
 Remove the screw plug (19) from the hub for link (3).

CENTA Antriebe Kirschey GmbH 24 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

WARNING
Injury and material damage can occur as a result of:
 Non-compliance with the operating instructions for the hydraulic
pumps
Before carrying out work with the hydraulic pumps, do not fail to read
their operating instructions. Only ever work with hydraulic pumps as
described in their operating instructions.

WARNING
Injury and material damage can occur as a result of:
 Hydraulic fluid spraying out
Use protective goggles.

IMPORTANT
We recommend the following mounting fluids:
 For mounting:
Oil with a viscosity 300 mm2/s at 20°C, e.g. SKF LHMF300
 For dismantling:
Oil with a viscosity 900 mm2/s at 20°C, e.g. SKF LHDF900

 Connect the pump (pmax= 3000 bar) for expanding the hub for link (3) to
the thread G¼ or G¾ (c).
 Screw the pump for pushing on the hub for link to the shaft.
 Build up the oil pressure to push on the hub for link.

WARNING
Material damage can occur as a result of:
 Too fast increase of the expanding pressure in the hub
The increase of the expanding pressure may not exceed
35 bar/minute.

WARNING
Material damage can occur as a result of:
 Insufficient expanding pressure in the hub
If the expanding pressure is too low, the necessary pushing pressure is
too high.

CENTA Antriebe Kirschey GmbH 25 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

 Slowly build up the oil pressure for expanding the hub for link.
 Build up the oil pressure alternately until the lift path (p up) of the hub for
link (3) is reached (for p up and reference faces, see installation drawing).
 Decrease the oil pressure for expanding the hub for link.
 Remove the pump for expanding the hub for link from the hub for link (3).
 Maintain the oil pressure for pushing on the hub for link for one hour.
 Decrease the oil pressure for pushing on the hub for link.
 Remove the pump for pushing on the hub for link from the shaft.
 Turn the hub for link (3), drain oil out of the thread G¼ or G¾ (c) and
dispose correctly.
 Screw the screw plug (19) into the hub for link (3).

IMPORTANT
Do not place a load on the hub for 24 hours.

IMPORTANT
The front edge of the shaft must not project. Otherwise, radial replacement of the
rubber elements is not guaranteed.

CENTA Antriebe Kirschey GmbH 26 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.3.3 Mounting the flange hub (3)

Fig. 6-5 Mounting the flange hub (3)

Item Info Designation Remark

3 Flange hub

C Flange Customer part

 Push the flange hub (3) onto/into the centring of the flange (C).
 Screw the flange hub (3) to the flange (C).

CENTA Antriebe Kirschey GmbH 27 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.4 Mounting the hub/adapter (4)


 Mount the hub/adapter (4) as appropriate for the type supplied (see
installation drawing):
 Mounting the hub (4) with cylindrical bore and keyway,
see chapter 6.4.1 .
 Mounting the hub (4) with conical oil interference fit,
see chapter 6.4.2 .
 Mounting the adapter (4), see chapter 6.4.3 .

6.4.1 Mounting the hub (4) with cylindrical bore and keyway

Fig. 6-6 Mounting the hub (4) with cylindrical bore and keyway

Item Info Designation Remark

4 Hub

B Shaft Customer part

a Face of shaft

b Face of hub

CENTA Antriebe Kirschey GmbH 28 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

CAUTION
Material damage can occur as a result of:
 Incorrect heating of the hubs/flange hubs
Heat the hubs/flange hubs steadily in an oil bath, a fan oven, on an
electric hot plate, either inductive or with a flame (ring burner).

CAUTION
Injuries can occur as a result of:
 Hot coupling components
Use suitable protective gloves.

 Heat the hub (4) to a temperature of 170° - 200°C.


 Push the hub (4) onto the shaft (B).

IMPORTANT
Face of shaft must not protrude to face of hub. Otherwise radial replacement of other
coupling parts is not guaranteed.

CAUTION
Material damage can occur as a result of:
 Hot hubs/flange hubs
Before further mounting of hubs/flange hubs, allow them to cool to
ambient temperature.

CENTA Antriebe Kirschey GmbH 29 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.4.2 Mounting the hub (4) with conical oil interference fit

Fig. 6-7 Mounting the hub (4) with conical oil interference fit

Item Info Designation Remark

4 Hub

19 Screw plug G¼ or G¾
see installation drawing

B Shaft Customer part

a Face of shaft

b Face of hub

c Thread G¼ or G¾
see installation drawing

 Lightly oil the cone of the shaft (B).


 Push the hub (4) onto the shaft (B).
 Remove the screw plug (19) from the hub (4).

CENTA Antriebe Kirschey GmbH 30 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

WARNING
Injury and material damage can occur as a result of:
 Non-compliance with the operating instructions for the hydraulic
pumps
Before carrying out work with the hydraulic pumps, do not fail to read
their operating instructions. Only ever work with hydraulic pumps as
described in their operating instructions.

WARNING
Injury and material damage can occur as a result of:
 Hydraulic fluid spraying out
Use protective goggles.

IMPORTANT
We recommend the following mounting fluids:
 For mounting:
Oil with a viscosity 300 mm2/s at 20°C, e.g. SKF LHMF300
 For dismantling:
Oil with a viscosity 900 mm2/s at 20°C, e.g. SKF LHDF900

 Connect the pump (pmax= 3000 bar) for expanding the hub (4) to the
thread G¼ or G¾ (c).
 Screw the pump for pushing on the hub to the shaft.
 Build up the oil pressure to push on the hub.

WARNING
Material damage can occur as a result of:
 Too fast increase of the expanding pressure in the hub
The increase of the expanding pressure may not exceed
35 bar/minute.

WARNING
Material damage can occur as a result of:
 Insufficient expanding pressure in the hub
If the expanding pressure is too low, the necessary pushing pressure is
too high.

CENTA Antriebe Kirschey GmbH 31 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

 Slowly build up the oil pressure for expanding the hub.


 Build up the oil pressure alternately until the lift path (p up) of the hub (4) is
reached (for p up and reference faces, see installation drawing).
 Decrease the oil pressure for expanding the hub.
 Remove the pump for expanding the hub from the hub (4).
 Maintain the oil pressure for pushing on the hub for one hour.
 Decrease the oil pressure for pushing on the hub.
 Remove the pump for pushing on the hub from the shaft.
 Turn the hub (4), drain oil out of the thread G¼ or G¾ (c) and dispose
correctly.
 Screw the screw plug (19) into the hub (4).

IMPORTANT
Do not place a load on the hub for 24 hours.

IMPORTANT
Face of shaft must not protrude to face of hub. Otherwise radial replacement of other
coupling parts is not guaranteed.

CENTA Antriebe Kirschey GmbH 32 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.4.3 Mounting the adapter (4)

Fig. 6-8 Mounting the adapter (4)

Item Info Designation Remark

4 Adapter

E Flange Customer part

 Push the adapter (4) onto/into the centring of the flange (E).
 Screw the adapter (4) to the flange (E).

6.5 Aligning the units


 Align the units to be connected (see chapter 5).

CENTA Antriebe Kirschey GmbH 33 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.6 Positioning the link flange assembly

Fig. 6-9 Positioning the link flange assembly

Item Info Designation Remark

1 Link flange assembly Pre-mounted by CENTA

1.1 Rubber segment

1.2 Link flange

3 Hub for link/Flange hub Illustrated is the hub for link

4 Hub/Adapter Illustrated is the hub

d Centring for link

 Position the link flange assembly (1) between the hub for link/flange hub (3)
and the hub/adapter (4).
 Slide the link flange assembly (1) over the hub for link/flange hub (3) and
place it on the hub for link/flange hub (3).
The centrings for the links (d) must point towards the hub for link/flange hub
(3).

CENTA Antriebe Kirschey GmbH 34 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.7 Mounting the centrifugal protection (D/F) assembly


 Mount the centrifugal protection assembly (D/F) as appropriate for the type
supplied (see installation drawing):
 Mounting the centrifugal protection assembly (D),
sizes 00050…00080 and 00082…00090, see chapter 6.7.1 .
 Mounting the centrifugal protection assembly (F),
size 00081, see chapter 6.7.2 .

CENTA Antriebe Kirschey GmbH 35 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.7.1 Mounting the centrifugal protection assembly (D),


sizes 00050…00080 and 00082…00090

Fig. 6-10 Mounting the centrifugal protection assembly (D)

Item Info Designation Remark

1 Link flange assembly

4 Hub/Adapter Illustrated is the hub

5.1 Rubber element

5.2 Ring

9 Screw ISO 4762-10.9

11 Ring

D Centrifugal protection assembly Pre-mounted by CENTA

 Push the centrifugal protection assembly (D) onto the centring of the
hub/adapter (4).
 Screw the hub/adapter (4) to the centrifugal protection assembly (D) using
the screws (9).

CENTA Antriebe Kirschey GmbH 36 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.7.2 Mounting the centrifugal protection assembly (F), size 00081

Fig. 6-11 Mounting the centrifugal protection assembly (F)

Item Info Designation Remark

1 Link flange assembly

4 Hub/Adapter Illustrated is the hub

5.1 Rubber element

5.2 Ring

9 Screw DIN912-10.9

13 Ring

F Centrifugal protection assembly Pre-mounted by CENTA

 Place the centrifugal protection assembly (F) between the link flange
assembly (1) and the hub/adapter (4) and support it.
 Push the ring (13) onto the centring of the hub/adapter (4).
 Push the centrifugal protection assembly (F) onto the centring of the
ring (13).
 Screw the hub/adapter (4) and the ring (13) to the centrifugal protection
assembly (F) using the screws (9).

CENTA Antriebe Kirschey GmbH 37 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.8 Connecting the rubber elements

Fig. 6-12 Connecting the rubber elements

Fig. 6-13 Detail X

CENTA Antriebe Kirschey GmbH 38 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

Item Info Designation Remark

1.1 Rubber element Part of link flange assembly

5.1 Rubber element Part of centrifugal protection


assembly

6.1 Sheet

6.2 Bolt 2x180°

6.3 Circlip DIN 471 2x180°

6.4 Nut

6.5 Screw ISO4762-10.9

6.6 Washer

X Detail See Fig. 6-13

e Drilling for bolt In rubber element (5.1)

f Drilling for bolt In rubber element (1.1)

IMPORTANT
Ensure during installation that the bolts are in the right position.

 Place the bolts (6.2; 2x180°) in the drillings (f) of the rubber element (1.1).
 Secure the bolts (6.2; 2x180°) using the circlip (6.3).
 Turn the rubber element (1.1) towards the rubber element (5.1) until the
drillings (e) in the rubber element (5.1) and the bolts (6.2) are aligned.
 Push together the rubber element (1.1) and the rubber element (5.1) until a
distance of approx. 5 mm is reached.
By doing so, place the bolts (6.2) into the drillings (e) of the rubber element
(5.1).

 Push two screws (6.5) with washers (6.5) through the drillings of the
rubber element (1.1).
 Push the sheet (6.1) onto the screws (6.5).
 Screw the rubber element (1.1), the sheet (6.1) and the rubber element
(5.1) loosely using the screws (6.5), washers (6.6) and nuts (6.4).
 Repeat the mounting section above until all sheets (6.1) are screwed loosely.
 Fasten all screws (6.5) by required tightening torque (see chapter 11.1).

CENTA Antriebe Kirschey GmbH 39 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.9 Removing the mounting supports


 Remove all mounting supports.

6.10 Mounting the links

IMPORTANT
 The links must be mounted in such a way that they are subjected to tensile load.A
differentiation is made between the direction of rotation left (ccw) and right (cw),
looking towards the driving end.
 Links are packaged in sets.
 All links of a link set are the same weight.
 Only mount links in complete sets "crosswise".
 Instructions on how to mount one link are provided following. Item numbers and
the part illustrations may differ slightly from the delivery state.

The following table gives an overview of the number of size of the links used.

CENTAX-L Link
Size Size Quantity

50/52/55/56 4

64/65/67 2 5

68 6

69/70/71 4

72 3 5

75 6
176/276

78 4
177/277

80/81 5
179/181/279/281
4
82/84/85 6
183/184/283/284

88 8

90 9

Table 6-1 Guide to links

CENTA Antriebe Kirschey GmbH 40 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

Fig. 6-14 Mounting the links ("ccw" counterclockwise rotation)

Fig. 6-15 Mounting the links ("cw" clockwise rotation)

CENTA Antriebe Kirschey GmbH 41 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

Item Info Designation Remark

X/Y Looking at the flange

1 Link unit

a Label "Flange"

b Label "Hub"

c The recess must be pointing towards


the flange

1.1 Collar sleeve

2 Hub/Tube

3 Flange

4 Bearing unit comprising:

4.1 PU bearing

4.2 Sliding bearing

d PTFE coating must be at the top

5 Washer for centrifugal bearing

6 Screw ISO4014-10.9 M.. Dimensions as shown in parts


list

7 Screw ISO4014-10.9 M.. Dimensions as shown in parts


list

8 Washer Only at size 3 and 4

 Set the link unit (1) marked "Flange" on the centring fixture of the
flange (3).
 Position the link side with the inscription "Hub" against the centring
fixture of the hub/tube (2).
 Tighten the screw (7; "Flange") with the washer (8; only at size 3 and 4)
and the screw (6; "Hub"), washer for centrifugal bearing (5) and the
bearing unit (4; PTFE coating must be at the top) alternately by hand
until the centring fixtures of the collar sleeves (1.1) are seated in the
centring fixtures of the hub/tube (2) / flange (3).
 Repeat the mounting section above until all links are mounted (for quantity
of the links, please see the table guide to links).
 Fasten the screws (6 and 7) of the link unit (1) by required tightening torque
"crosswise".

CENTA Antriebe Kirschey GmbH 42 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

6.11 After completed mounting

WARNING
Injury and material damage can occur as a result of:
 Loose screw connections
Before commissioning, the tightening torque levels of all screws must
be checked and corrected if necessary.

Before commencing long-term operation, the plant must successfully complete a


test run.

CENTA Antriebe Kirschey GmbH 43 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

7 Operation

WARNING
Injury and material damage can occur as a result of:
 Worn coupling components
If the running noises change and/or vibrations occur turn the plant off
immediately.

Determine the fault and its root cause, and remedy.


The troubleshooting process is simplified by the table in the next chapter.
On principle in case of a fault, an analysis of the entire plant should be
performed.

7.1 Operating faults, root causes and remedy

Faults Possible root Remedy


causes

Running noises or Alignment error 1. Switch off the plant


vibrations in the
2. Check alignment, correct if applicable
plant
3. Trial run

Loose screws 1. Switch off the plant


2. Check alignment, correct if applicable
3. Check screw torque levels and correct if
necessary
4. Trial run

Breakage of the Alignment error 1. Switch off the plant


rubber element
2. Exchange defective parts
3. Check alignment, correct if applicable
4. Trial run

Inadmissibly high 1. Switch off the plant


torque
2. Exchange defective parts
3. Check alignment, correct if applicable
4. Trial run

Table 7-1 Troubleshooting table

In case of uncertainty or if you have questions, please contact our head office
(address see chapter 1).

7.2 Admissible overall misalignment of the coupling


The overall misalignment values can be found in the catalogue.

CENTA Antriebe Kirschey GmbH 44 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

8 Care and maintenance

WARNING
Injuries can occur as a result of:
 Contact with rotating parts
Before starting work at the coupling, switch off the plant and secure
against unintentional start-up.

The coupling requires low maintenance. It is possible to perform a visual


inspection during the regular scheduled maintenance intervals for the complete
unit. Every 12 month a visual inspection is strictly required.

8.1 Work to be performed


8.1.1 Cleaning the coupling
 Remove any loose dirt from the coupling.

8.1.2 Visual inspection of the coupling


 Inspect the coupling for cracks, chips or missing parts.
 Replace faulty and missing parts.

8.1.3 Visual inspection of links


 Make a visual inspection of the links every 12 months.

Pay particular attention to the rubber bushes of the links. Squash folds and small
cracks of up to 1 mm may be considered normal.
In the case of crack depths in excess of 1 mm, or detachment of the rubber-to-
metal bond, the links must be exchanged.

IMPORTANT
Exchange the links:
 In the event of damage
 When replacing the rubber elements

IMPORTANT
 Links are packaged in sets.
 All links of a link set are the same weight.
 Only mount or replace links in complete sets.

CENTA Antriebe Kirschey GmbH 45 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

8.1.4 Visual inspection of the rubber elements / rubber segments

IMPORTANT
Exchange the rubber elements / rubber segments in the event that:
 The wear specifications given in W000-00002 are exceeded

 Assess the rubber elements / rubber segments as described in CENTA


guidelines W000-00002.

8.1.5 Inspection of the screw connections


 Check the tightening torque levels of all screws and if necessary, correct.

8.2 Replacing defective parts


 Remove the coupling as described in chapter 9.
 Replace wearing parts.
 Mount the coupling as described in chapter 6.

CENTA Antriebe Kirschey GmbH 46 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

9 Dismantling
9.1 General dismantling instructions
Any work method which impairs the safety of the coupling is prohibited.
The user undertakes to notify the manufacturer immediately of any changes
occurring at the coupling which could impair safety (address see chapter 1).

IMPORTANT
The coupling is dismantled in reverse order to the assembly process.
Please refer to the illustrations in chapter 6.

WARNING
Injuries can occur as a result of:
 Contact with rotating parts
Before starting work at the coupling, switch off the plant and secure
against unintentional start-up.

WARNING
Injury and material damage can occur as a result of:
 Dismantling of the coupling in the wrong sequence
Only ever dismantle the coupling in the described sequence.

WARNING
Injury and material damage can occur as a result of:
 Falling coupling components
Secure coupling components against falling to the floor.

CAUTION
Material damage to coupling components can occur as a result
of:
 Contact with sharp-edged objects
Protect coupling components for transportation.
Only hoist coupling components with nylon belts or ropes.
Always cushion parts when supporting them from below.

IMPORTANT
Use suitable lifting devices for dismantling.

CENTA Antriebe Kirschey GmbH 47 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

9.2 Dismantling the links


See Fig. 6-14 or 6-15:
 Loosen the screws (6 and 7) of the links (1) alternately ("Flange"/"Hub") and
remove with washers (8; with link size 3 and 4 only), bearing unit (4) and
washers for centrifugal bearing (5).
 Remove the links (1).

9.3 Disconnecting the rubber elements


See Fig. 6-12 and 6-13:
 Loosen the screws (6.5) of the connection rubber element (1.1) and rubber
element (5.1).
 Support the rubber element (1.1).
 Separate the rubber element (1.1) approx. 10mm from the rubber element
(5.1).
 Remove the screws (6.5) with the washers (6.6), the nuts (6.4) and the
sheets (6.1).
 Place the rubber element (1.1) on the hub for link/flange hub (3),
see fig. 6.9 .
 Pull the circlips (6.3) from the bolts (6.2) and remove them as well as the
bolts. (2x180°).

9.4 Dismantling the centrifugal protection assembly (D/F)


 Dismantle the centrifugal protection assembly (D/F) as appropriate for the
size supplied (see installation drawing):
 Dismantling the centrifugal protection assembly (D),
sizes 00050…00080 and 00082…00090, see chapter 9.4.1 .
 Dismantling the centrifugal protection assembly (F),
size 00081, see chapter 9.4.2 .

9.4.1 Dismantling the centrifugal protection assembly (D), sizes


00050…00080 and 00082…00090
See Fig. 6-10:
 Loosen the screws (9) of the connection hub/adapter (4) and centrifugal
protection assembly (D) and remove.
 Pull the centrifugal protection assembly (D) off the centring of the
hub/adapter (4) and remove.

9.4.2 Dismantling the centrifugal protection assembly (F), size 00081


See Fig. 6-11:
 Loosen the screws (9) of the connection hub/adapter (4), ring (13) and
centrifugal protection assembly (F) and remove.
 Pull the centrifugal protection assembly (F) and ring (13) off the centring of
the hub/adapter (4) and remove.

CENTA Antriebe Kirschey GmbH 48 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

9.5 Dismantling the link flange assembly (1)


See Fig. 6-9:
 Remove out of the installation space the link flange assembly (1).

9.6 Removing the mounting supports


 Remove all mounting supports.

9.7 Dismantling the hub/adapter (4; if necessary)


 Dismantle the hub/adapter (4) as appropriate for the supplied design (see
installation drawing):
 Dismantling the hub (4) with cylindrical bore and keyway,
see chapter 9.7.1 .
 Dismantling the hub (4) with conical oil interference fit,
see chapter 9.7.2 .
 Dismantling the adapter (4), see chapter 9.7.3 .

9.7.1 Dismantling the hub with cylindrical bore and keyway


See Fig. 6-6:
 Remove the hub (4) from the shaft (B).

9.7.2 Dismantling the hub with conical oil interference fit


See Fig. 6-7:

WARNING
Injury and material damage can occur as a result of:
 Non-compliance with the operating instructions for the hydraulic
pumps
Before carrying out work with the hydraulic pumps, do not fail to read
their operating instructions. Only ever work with hydraulic pumps as
described in their operating instructions.

WARNING
Injury and material damage can occur as a result of:
 Hydraulic fluid spraying out
Use protective goggles.

WARNING
Injuries and material damages can occur by:
 Suddenly loosening hubs
Secure the hub with a hydraulic tool against sudden axial loosening.

CENTA Antriebe Kirschey GmbH 49 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

IMPORTANT
We recommend the following mounting fluids:
 For mounting:
Oil with a viscosity 300 mm2/s at 20°C, e.g. SKF LHMF300
 For dismantling:
Oil with a viscosity 900 mm2/s at 20°C, e.g. SKF LHDF900

 Remove the screw plug (19) from the hub (4).


 Connect the pump (pmax= 3000 bar) to the thread G¼ or G¾ (c) of hub (4)
to expand the hub.
 Screw the pump to the shaft (B), in order to hold the hub.
 Build up oil pressure in order to hold the hub.

WARNING
Material damage can occur as a result of:
 Too fast increase of the expanding pressure in the hub
The increase of the expanding pressure may not exceed
35 bar/minute.

 Slowly build up oil pressure to expand the hub (pmax= 1500 bar).
 Slowly reduce the oil pressure for holding the hub.
 Slowly reduce the oil pressure for expanding the hub.
 Repeat the above mounting section until the hub is completely released from
the shaft.
 Remove the pump for holding the hub from the shaft (B).
 Remove pump for expanding the hub from the hub (4).
 Turn the hub (4), drain oil out of the thread G¼ or G¾ (c) and dispose
correctly.
 Screw the screw plug (19) into the hub (4).
 Remove the hub (4) from the shaft (B).

9.7.3 Dismantling the adapter (4)


See Fig. 6-8:
 Loosen and remove the screws of the connection adapter (4) and flange (E).
 Pull the adapter (4) out of/off the centring of the flange (E) and remove.

CENTA Antriebe Kirschey GmbH 50 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

9.8 Dismantling the hub for link/flange hub (3; if necessary)


 Dismantle the hub for link/flange hub (3) as appropriate for the supplied
design (see installation drawing):
 Dismantling the hub for link (3) with cylindrical bore and keyway,
see chapter 9.8.1 .
 Dismantling the hub for link (3) with conical oil interference fit,
see chapter 9.8.2 .
 Dismantling the flange hub (3), see chapter 9.8.3 .

9.8.1 Dismantling the hub for link (3) with cylindrical bore and keyway
See Fig. 6-3:
 Remove the hub for link (3) from the shaft (A).

9.8.2 Dismantling the hub for link (3) with conical oil interference fit
See Fig. 6-4:

WARNING
Injury and material damage can occur as a result of:
 Non-compliance with the operating instructions for the hydraulic
pumps
Before carrying out work with the hydraulic pumps, do not fail to read
their operating instructions. Only ever work with hydraulic pumps as
described in their operating instructions.

WARNING
Injury and material damage can occur as a result of:
 Hydraulic fluid spraying out
Use protective goggles.

WARNING
Injuries and material damages can occur by:
 Suddenly loosening hubs
Secure the hub with a hydraulic tool against sudden axial loosening.

CENTA Antriebe Kirschey GmbH 51 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

IMPORTANT
We recommend the following mounting fluids:
 For mounting:
Oil with a viscosity 300 mm2/s at 20°C, e.g. SKF LHMF300
 For dismantling:
Oil with a viscosity 900 mm2/s at 20°C, e.g. SKF LHDF900

 Remove the screw plug (19) from the hub for link (3).
 Connect the pump (pmax= 3000 bar) to the thread G¼ or G¾ (19) of hub
for link (3) to expand the hub.
 Screw the pump to the shaft (A), in order to hold the hub for link.
 Build up oil pressure in order to hold the hub for link.

WARNING
Material damage can occur as a result of:
 Too fast increase of the expanding pressure in the hub
The increase of the expanding pressure may not exceed
35 bar/minute.

 Slowly build up oil pressure to expand the hub for link (pmax= 1500 bar).
 Slowly reduce the oil pressure for holding the hub for link.
 Slowly reduce the oil pressure for expanding the hub for link.
 Repeat the above mounting section until the hub for link is completely
released from the shaft.
 Remove the pump for holding the hub for link from the shaft (A).
 Remove pump for expanding the hub for link from the hub for link (3).
 Turn the hub for link (3), drain oil out of the thread G¼ or G¾ (19) and
dispose correctly.
 Screw the screw plug (19) into the hub for link (3).
 Remove the hub for link (3) from the shaft (A).

9.8.3 Dismantling the flange hub (3)


See Fig. 6-5:
 Loosen and remove the screws of the connection flange hub (3) and flange (C).
 Pull the flange hub (3) out of/off the centring of the flange (C) and remove.

9.9 Reassembling the coupling


 Reassemble the coupling as described in chapter 6.

CENTA Antriebe Kirschey GmbH 52 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

10 Wearing and spare parts

WARNING
Injury and material damage can occur as a result of:
 Mounting and/or utilization of non-original CENTA parts
Never use parts from other manufacturers.

A stock of the most important wearing and spare parts is the most important
condition to ensure that the coupling is functional and ready for operation at all
times.

We only provide a warranty for CENTA original parts.

Wearing parts of this coupling:


 The link kits. These contain all screws, washers and bearing units. In the
event that links or rubber bushes of the link are faulty, they must be
replaced as a complete set.
 The rubber element(s). When exchanging the rubber element(s), all screw
connections must be renewed. These must be ordered separately.

IMPORTANT
 Links are packaged in sets.
 All links of a link set are the same weight.
 Only mount or replace links in complete sets.

When ordering a spare, specify:


 Order no.
 Coupling order no.
 Drawing no.

CENTA Antriebe Kirschey GmbH 53 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

11 Annex
11.1 CENTA data sheet D013-013 (lubricated screw connections)
Validity:
For all non-dynamically stressed screw connections with lubricated shank bolts
in accordance with ISO 4014, ISO 4017 and ISO 4762 (DIN 912) with metric
standard thread in accordance with DIN ISO 262, unless other specifications are
given on CENTA documents.
Preparation of parts that are to be screwed together:
The joining areas must be free of dirt, preservatives and lubricants.
Preparation of screws that ARE NOT secured with liquid screw locking
medium:
Give the screws extra lubrication with motor oil under the screw head and in the
thread.
Preparation of screws that ARE secured with liquid screw locking
medium:
Give the screws extra lubrication with motor oil under the screw head. Remove
all grease from the thread.
Screw tightening method:
Screw in (by hand with torque wrench).

CENTA Antriebe Kirschey GmbH 54 / 55


Assembly and operating instructions M016-00004-EN

CENTAX-L Rev. 2

016L-00050...00090-SS/FS/FF20

11.2 CENTA data sheet D016-900


Declaration of incorporation according to the EC Machinery
Directive 2006/42/EC, Appendix II B

Manufacturer: Contact:
CENTA Antriebe Phone +49-2129-912-0
Kirschey GmbH Fax +49-2129-2790
Bergische Strasse 7 centa@centa.de
42781 Haan / GERMANY www.centa.info

We herewith declare that the incomplete machine

Product: Highly elastic coupling CENTAX-L

Model / series code: CX-L / 016L

Installation size: 50…90

Design: all

Serial number: according to shipping documents, if applicable

- provided this is possible as far as the scope of supply is concerned - complies


with the following basic requirements of the Machinery Directive 2006/42/EC
Appendix I, subchapters 1.1.2, 1.1.3, 1.1.5, 1.3.2, 1.3.3, 1.3.4 and 1.5.4.
In addition, we declare that the special technical documents for this incomplete
machine were compiled according to Appendix VII Part B and undertake to
forward these to the market monitoring authorities by request via our
"Documentation Department".
Commissioning of the incomplete machine is interdicted until the incomplete
machine has been incorporated in a machine and the latter complies with the
provisions of the EC Machinery Directive and the EC Declaration of Conformity
according to Appendix II A is on hand.
The declaration is invalidated by every modification to the delivered parts.

Authorised representative for the


compilation of the relevant technical
documents:
by order of Gunnar Anderseck
(Authorised Person Documentation)

Declaration of incorporation was issued:

by proxy Dipl.-Ing. Jochen Exner


Haan, 09.12.2009
(Design Management)

CENTA Antriebe Kirschey GmbH 55 / 55

You might also like