OOCL Reefer Inspection (PTI) Complete Guide 2024

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 11

OOCL Reefer Inspection (PTI) Complete Guide 2024

Contents
1. Purposes of Reefer Inspection (PTI)
2. Kinds of Reefer Inspection
3. PTI Application Criteria
4. Special Test Application Criteria
5. Procedures of Reefer Inspection (PTI)
6. How to Disable Dehumidification Function
7. Q&A
Appendix 1 - Special Reefer Series in 2024
==============================================================

1. Purposes of Reefer Inspection (PTI)


Reefer Inspection is performed to ensure that the reefer is in sound and functional conditions. Thus,
to ensure reefer service, Reefer Inspection is carried out before releasing the reefer unit to the
customer.

2. Kinds of Reefer Inspection


There are three kinds of Reefer Inspection:
(I) Regular PTI
(II) Smart PTI
(III) Special Test

(I) Regular PTI

Nature: Inspection service to ensure that a reefer is serviceable before releasing reefer to customer
for export loading.
General policy: Chill PTI is applied to the aged 9 or younger reefers in OOCL fleet, while AUTO
PTI for the reefer at 10 years or older.

 Please refer to the commission date in the machinery panel or the manufacturer’s system etc
resource, or enquire OOCL of the built year, if you are uncertain about the container age.

Terminology Also known Description


as
Chill PTI Chilled PTI PTI for boxes at age 9 or younger. Select the ‘Chilled’ PTI
(TK/Daikin) or “Auto3” (Carrier) checking function in the
reefer controller; If there is data download, it will be Chill PTI (D)
Full PTI Long PTI PTI for boxes at 10 years or older. Select the ‘Full’ PTI
(formerly (TK/Daikin) or “Auto2” (Carrier) checking function in the reefer
Auto PTI) controller. If there is data download, it will be Auto PTI (D)

728779640.docx
1 of 11
(II) Smart PTI (also known as e-PTI)

Nature: Visual inspection service to a reefer which already passed the continuous function test of
machinery performance during previous shipment, to ensure the reefer is serviceable before
releasing reefer to customer for export loading

(III) Special Test (also Extended PTI for Special Shipment)

Nature: Special inspection service for the operation of special features of the reefer.

Terminology Details
Special test for In case of deep-frozen reefer shipment, i.e. booking temperature
deep frozen cargo below minus 23 degC (-23°C), additional testing requirements are
required.
EXCEPTION: For TK Magnum, Deep Frozen Test will be carried out
ONLY when the setting is below minus 25degC (-25°C).
CA Test In case of CA shipment, additional testing requirements are required

3. PTI Application Criteria


PTI Form Applications

Regular PTI Smart PTI Special Test


Chill PTI Full PTI Smart PTI Deep CA test
(at 9 or younger) (at 10 or older) Frozen test
TK √ √ x √ x
Magnum (Below -25°C)

Daikin √ √ Note 1 √ Note 2


(Below -23°C)
Carrier √ √ x √ x
(Below -23°C)

Note 1: subject to OOCL instruction, with PTI instruction in Smart PTI platform
Note 2 Specific series of Daikin units

3.1 Reefers with Smart PTI recommended in Smart PTI platform

The vendor should carry out:


(I) Smart PTI except:
i. The reefer whose structure & its insulation have been repaired, e.g. panel patching more
than 240 x 360cm, and/or whose electrical components have been found visual damage,
such as missing.

728779640.docx
2 of 11
Excluding those repair work with no impact onto the box Insulation and Refrigeration
System functioning:
1. Cleaning of the box and/or machinery,
2. Repair of the electrical component, e.g. power plug, cable,
3. Repair of door handle and corner casting
ii. The reefer is involved in cargo claim or customer’s complaint about cargo quality.
iii. Special request from OOCL via Smart PTI platform or via email etc.

(II) Regular PTI (Chill or Full PTI) under conditions (i) to (iii) in (I)

3.2 Reefers at 9years (built in 2015) or younger – (please refer to Appendix 1)

The vendor should carry out:


(I) Chill PTI except:
i. the reefer whose Refrigeration System / Insulation has been repaired, e.g., leakage,
compressor and panel patching more than 240 x 360cm.
Excluding those repair work with no impact onto the box Insulation and Refrigeration
System functioning:
1. Cleaning of the box and/or machinery,
2. Repair of the electrical component, e.g., heater, LPCO, sensors, power plug, cable,
3. Repair of door handle and corner casting
ii. The reefer is involved in cargo claim or customer’s complaint about cargo quality
iii. Special request from OOCL.

(II) Full PTI under conditions (i) to (iii) in (I).

3.3 Reefers at 10 years (built in 2014) or older

The vendor should carry out: Full PTI.

3.4 Inspection of RH Sensor during PTI

i. For the booking with the request of de-humidification control,

 Issue boxes aged 5 or younger for dehumidification shipment.


 If there’s NO reefer aged 5 or younger at stock, the vendor could select reefer over 5-year-old
for dehumidification booking, however, the vendor should report to OOCLMNR for pre-
approval especially when having the humidity sensor failure.
 Make sure RH sensor is to be tested via controller menu to verify the sensor accuracy. For
details, refer to OOCLMNR bulletin (OOCLMNR001)

ii. For a reefer not prepared for de-humidification booking

728779640.docx
3 of 11
 If the box aged 5 years or younger which is still covered under warranty period, don’t disable
dehumidification function as long as it is a unit equipped with RH Sensor.
 For a box at 6years old or over, specifically described as follows:

a. Thermoking reefer: needn’t inspect RH Sensor during Chill or Long PTI inspection;
refer to item 7 about how to disable dehumidification function.
b. Daikin reefer: No need to manually disable dehumidification function,as De-hum
feature will default off after Long/Chill PTI
c. Carrier Reefer: Don’t disable the humidification feature without OOCL pre-approval.

3.5 Supplementary provisions

1) Regular PTI Validity Period is 60 days, and Smart PTI validity is 30 Days

2) If the reefer has been positioned by vessels from other location and still within 60 days after
latest PTI, POL OPS Team or RFT/HKG Team might provide reefer list to POD team who are
requested to share the reefer list with the vendor and remind the vendor to check reefer carefully
during gate inspection while no PTI is required.

3) If the reefer is empty returned by the shipper due to booking cancelation or other reasons after
release for booking shipment and still within 60days after latest regular PTI, needn’t do regular
PTI again.
 If it is Smart PTI performed for one export booking, but the booking is cancelled after
booking release, the reefer needs regular PTI again once after empty return.

Except:
i. If there is a visual heavy damage of the reefer box and/or machinery. PTI is required per PTI
Application Criteria after the damage is rectified or repaired,

ii. If there is any malfunctioning report on the unit or customer’s complaint about the reefer
performance, PTI is required per PTI Application Criteria.

iii. Special request from OOCL to do PTI.

4) For all the reefers aged at or below 9, the insulation is sound without significant normal wear &
tear and the machinery is new. Thus, we only need to carry out the checking of the reefer
machinery plus the sensor checking at +0.0degC. No need to check the performance at -18degC.

5) The Conventional PTI will be carried out by PM centers, or specific vendors assigned by OOCL
for thorough checking of the reefers, with download data submitted.

6) For brand new reefer being first delivered from the factory to in-service fleet,

728779640.docx
4 of 11
6.1 No PTI is required for Local Use of new reefer unless the new reefer has been idling at
factory over 180days.
6.2 No PTI is required if new reefer is empty positioned to other location as long as the reefer
has been idling at factory not over than 60days after commissioning date.

Except:
I. PTI is required if new reefer is empty positioned to other location while the reefer has
been idling at factory over than 60days after commissioning date.
II. If there is a visual heavy damage of the reefer box and/or machinery, or any part
missing. PTI is required per PTI Application Criteria after the damage is rectified or
repaired.
III. Special request from OOCL to do PTI.

4. Special Test Application Criteria


As the name implies, Special Test is to be carried out for Special Booking Requirement:

i. Deep Frozen Cargo booking

If there is a booking with set temperature below minus 23degC(-23oC), e.g. minus 30degC(-
30oC), the Special Test – Deep Frozen Cargo is to be carried out before issuing the box.

EXCEPTION: For TK Magnum, Deep Frozen Test will be carried out ONLY when the
setting is below minus 25degC (-25oC).

ii. CA test

If there is a booking required of CO2/O2 setting upon the customer’s requirement, CA test is
to be carried out according to the manual before issuing the box.

 Running Test (Also known as pre-cooling)

If there is a booking required of pre-cooling of reefer box upon the customer’s requirement,
the selected Reefer is to be set at the booking temperature, and to be carried out of Running
Test till arrival at booking temperature.

Pre-cooling of reefer is not recommended and subjected to endorsement of OOCL RFT/HKG


beforehand.

728779640.docx
5 of 11
5. Procedures of Reefer Inspection (PTI)
All report forms can be found in DepotSmart.

5.1 Regular PTI

5.1.1 Chill PTI (Also known as Chilled PTI)

The procedures are automated by means of the reefer machinery’s microprocessor.

The procedures consist of:


i. Before switching on, visual inspection is carried out.
ii. After switching on, check and verify the Microprocessor settings, such as a, container number to
be correct; b. the date to be correct; c. time to be GMT, d. optional functions etc
 For Thermoking reefer aged 6-years old or above and not for de-humidification
booking, make sure the dehumidification function is disabled unless dehumidification
function is required in booking instruction. Refer to Item# 7 How to Disable
Dehumidification Function in this guideline.
iii. Select the PTI function of the Microprocessor as below and run the unit:
 For Thermoking, select “Chilled PTI”;
 For Daikin DECOS III Select “Chilled PTI”;
 For Carrier, select “Auto 3’

 In case one reefer requiring of Chill PTI just run with “Brief PTI” (TK), or “S. PTI” (Daikin), (for example,
no Chill PTI menu is found in the controller menu), it needs to set and run the unit to +0.0degC to check
stability at zero setting, or re-test according to above-mentioned step iii;

iv. After Chill PTI pass, record down the necessary readings, Calibrate/Replace sensors, if
necessary.

5.1.2 Full PTI (also known as Long PTI, formerly Auto PTI)

The procedures are automated by means of the reefer machinery’s microprocessor.

The procedures consist of:


i. Before switching on, visual inspection is carried out.
ii. After switching on, check the Microprocessor settings, such as a, container number to be
correct; b. the date to be correct; c. time to be GMT, d. optional functions etc
 For Thermoking reefer aged 6-years old or above and not for de-humidification
booking, make sure the dehumidification function is disabled unless dehumidification
function is required in booking instruction. Refer to Item# 7 How to Disable
Dehumidification Function in this guideline.

iii. Select the PTI function of the Microprocessor as below and run the unit:
 For TK, select “PTI Test”.

728779640.docx
6 of 11
 For Daikin DECOS III, select “F.PTI”.
 For Carrier, select “Auto2”

5.1.4 Differences between Chill PTI and Full PTI

Chill PTI Full PTI


Measurement Measurement recorded Measurement recorded by the
by the controller controller
Process i. Controller testing i. Controller testing
ii. Capacity testing ii. Capacity testing
iii. Run at 0degC iii. Run at 0degC
iv. Defrost checking
v. Run to -18degC

5.2 Smart PTI

The procedure is the visual inspection of structure and electrical parts according to OOCL reefer Inspection
criteria and PTI guide to determine whether the reefer unit has any physical damage.

The procedures consist of:


i. Ensure unit structure and components have No physical damage and none are missing/loose/clogged
(box, mounting bolts, drain cap, kazoo, drain hoses, ventilator, etc.)
ii. Check electrical parts for any broken, loose connections, corrosion or missing etc damage to ensure
they are intact (power cable, plug, contactor and relays, wires harness, terminals, switches, IOT
device etc)
iii. Ensure cleanliness: no extra labels, debris, remains, etc.

 The check list is also specified in Appendix 2 for reference only (but not limited to)

5.3 Special Test (also Extended PTI for Special Shipment)

5.3.1 Special test for deep frozen cargo

(Booking with set temperature below minus 23 deg Celsius, e.g. minus 30degC)

In case of deep frozen cargo booking, all vendors have to comply with the following requirements before
releasing the box for stuffing:

1) If the set temperature of reefer is below -23degC, select container with age at 5 or younger. Please refer to
below table regarding the priority of Reefer machinery to be released.
2)

728779640.docx
7 of 11
Temperature setting Reefers to be used (1, 2, 3 = 1st, 2nd and 3rd priority)
20’RF < -23degC to -30degC 1. TK Magnum; 2. Carrier; 3. Daikin
< -30degC TK Magnum ONLY
40’RQ < -23degC to -25degC 1. TK Magnum; 2. Carrier; 3. Daikin
< -25degC to -30degC 1.TK Magnum; 2. Carrier; 3. Daikin.
Select Carrier/Daikin at 5years old or younger if no TK
magnum available; the younger, the better
< -30degC TK Magnum ONLY, the younger, the better
 If there is no reefer with age at 5 or younger, the next youngest one should be picked ; Special test for
deep frozen cargo should be carried out.
 EXCEPTION: For TK Magnum, Deep Frozen Test is not required when the set point is below -23°C to -
25°C.

3) Perform PTI/Special Test as per OOCL standard PTI procedure and ensure good air-tightness and sound
conditions of box.
 No crack on both interior and exterior panels.
 Door gaskets are in good condition and water tight.
 No missing bolts
 Drain hoses are installed properly.
 And etc.

4) After passing PTI, set the unit as per booking requirement. Record the time required to pull the box
temperature to the booking temperature. If the pull-down time is > 5 hours, please check the box
conditions and report to OOCL (ooclmnr@oocl.com).

5.3.3 Special test for CA cargo

In case of CA booking, all vendors should comply with the following requirements before releasing the box
for stuffing:

1) Select appropriate container with CA feature. (The CA container please see appendix).

2) Perform PTI as per OOCL standard PTI procedure and ensure good air-tightness and sound conditions of
box
3) Select CA Test menu in the controller to carry out CA Test according to the manufacturer specified
procedure.

6. How to Disable Dehumidification Function


 TK MP4000 Controller Unit:
(Menus: Classic Menu → Config → Options → Humidity Sensor → None)

728779640.docx
8 of 11
1) Press the F4 key to enter the Classic menu list and then press the F3 key to scroll to
[CONFIG].
2) Press the F4 key and then press the F3 key to scroll to [OPTION].
3) Press the F4 key and then press the F3 key to scroll to [HUMIDITY SENSOR].
4) Press the F4 key and then press the F3 key to scroll to [NONE].
5) Hold the F4 key to enter.

 TK MP3000/MP3000A controller unit:


(Menus: Main Menu → Configuration → Unit Type → Enter Password → No HUM)

1) Press the F2 or F3 key to enter the menu list.


2) Repeatedly press the F2 or F3 key to scroll through Main menu until [CONFIGURATION]
appears in LCD display.
3) Press the F4 key to access the Configuration menu. Repeatedly press the F2 or F3 key to
scroll to [UNIT TYPE]
4) Press the F4 key, display shows [PASSWORD], press the F2 key, and then press the “0”
Key to input password “A”.
5) Press the F4 key, and then press the ESC key. Press the F2 or F3 key until [NO HUM]
appears.
6) Hold the F4 key until the cursor stops flashing.

7. Q&A

In case of any question, please kindly send email to OOCLMNR@OOCL.COM.

Appendix 1 – Special Reefer Series

Simple guidelines -
1. Built in 2015 or younger - Chill PTI only
(if there is any exception as stated in the PTI Guide, carry out AUTO PTI)

2. Built in 2014 or older - AUTO PTI


(Unless otherwise requested by OOCL)

3. Special Booking – Deep Frozen,CA - Same PTI as above plus special tests.

CONTAINER SERIES RANGES -

1. For Chill PTI – below series of reefers will be carried out Chill PTI unless the conditions as mentioned in
clause 3.1 occur.

728779640.docx
9 of 11
40RQ Year 40RQ Year 20RF Year
OOLU626400-627049 2015 OTPU608611-609110 2020 OOLU395410-396409 2015
OOLU627050-629799 2015 OTPU611626-614140 2020 OOLU206700-207499 2020
OOLU632300-632499 2015 OTPU618141-619140 2020
OOLU629800-629999 2019 SEGU971102-971601 2020
OOLU633500-633999 2019 SEGU980598-981097 2020
OOLU651900-653099 2019 SEGU981598-981847 2020
OOLU674000-674099 2019 SEGU982348-982597 2020
OERU408313-410812 2019 SEGU988108-988267 2020
OERU417583-418226 2020 FBIU506391-507390 2021
OERU480519-480574 2020 FSCU530001-535700 2021
FBIU517988-519829 2023 FSCU598231-599530 2021
FBIU548321-548880 2023 OERU480735-481014 2022
FBIU548881-549020 2023 OERU420067-423286 2022
FBIU549021-549794 2023 OTPU653824-654323 2022
FBIU549795-549860 2023
SEKU917541-931033 2023
OERU426627-427426 2023

Above series are some of containers at 9years or younger; if not in the list (for example, those
leased-in reefer), please usually refer to the commission date in the machinery panel or the
manufacturer’s system etc resource or enquire OOCL of the built year.

2. For Deep Frozen Cargo Shipment – Reefer Machineries that are allowed to be used

Temperature setting Reefers to be used (1, 2, 3 = 1st, 2nd and 3rd priority)
20’RF < -23degC to -30degC 1. TK Magnum; 2. Carrier; 3. Daikin
< -30degC TK Magnum ONLY
40’RQ < -23degC to -25degC 1. TK Magnum; 2. Carrier; 3. Daikin
< -25degC to -30degC 1.TK Magnum; 2. Carrier; 3. Daikin.
Select Carrier/Daikin at 5years old or younger if no TK
magnum available; the younger, the better
< -30degC TK Magnum ONLY, the younger, the better

 For bookings with set temp between -25°C and -30°C, equipment release priority as below:
1). TK Magnum with age below 5 years
2). TK Magnum with age above 5 years, subject to container condition
3). Carrier with age below 5 years
4). Daikin with age below 5 years

 For bookings with set temp below -30°C, only TK Magnum units shall be released, the
younger the better

728779640.docx
10 of 11
3. For CA Shipment – below series of reefers are installed with CA device

40RQ Number Maker Date Built Size/type


OERU480735–481014 Daikin 2022 40RQ
FBIU507311-507390 Daikin 2021 40RQ
FSCU599331-599530 Daikin 2021 40RQ
OERU480519-480574 Daikin 2020 40RQ
OOLU674000-674099 Daikin 2019 40RQ
FBIU549795-549860 Daikin 2023 40RQ
FBIU548881-549020 Carrier 2023 40RQ

Appendix 2 – Check list for Smart PTI

No. General Visual inspection Items


1 Check fasteners, bolts and suspensions, hatches and doors on the machine; Replace or repair if necessary
2 Check all valve caps for any missing
3 Check that compressor and fan motor mountings are proper secured, tighten if necessary
Check condenser coil for cleanliness, obstructions, excessive corrosion or structural damage, Clean if
4 necessary
Check wiring terminals and connections inside control box and external to components including IOT device, for
5 any loose or broken connections
6 Check that wiring to all contactors/relays are secure and these are wired correctly.
check and ensure control box door can be secured correctly and the door gasket/seal is in good order including
7 IOT antenna.
8 Check defrost drain lines/hoses for obstructions and clear if necessary. Wash with fresh water.
Check Power cable and plug are without damage and check any splices have been carried out correctly.
9 Rework / replace as required.
10 Check unit, piping and components for leakage and cleanliness.
11 Check the cable tray compartment if any debris, and remove if any
12 Check and close air ventilation damper/door for tightness
Check reefer body for any structure damage including the evaporator rear plates; Check channels or “T” bar
13 floor for cleanliness; Channels must be free of debris for proper air circulation
14 Check drain plugs/kazoos for any missing or damage etc
15 Ensure doors are closed/locked (reefer, control box, ventilator, etc.)
16 Set reefer (temperature etc) to booking requirement if any
Check to ensure main circuit breaker, On/Off switch and/or power selection switch (if any) at OFF position;
17 unplug and Coil up cable correctly.
18 Remove all foreign labels and stickers.
19 Attach PTI sticker on dedicated spot and fill in necessary information

- END -