POWER HUB

User Manual V1.5

EFM100-HUB (LV)
EFM100-HUB-F (LV)
EN

Disclaimer

Read this user manual carefully before using the product to ensure that you
completely understand the product and can correctly use it. After reading this user
manual, keep it properly for future reference. Improper use of this product may cause
serious injury to yourself or others, or cause product damage and property loss. Once
you use this product, it is deemed that you understand, approve and accept all the
terms and content in this document. EcoFlow is not liable for any loss caused by the
user's failure to use this product in compliance with this user manual.

In compliance with laws and regulations, EcoFlow reserves the right to final
interpretation of this document and all documents related to this product. This
document is subject to changes (updates, revisions, or termination) without prior
notice. Please visit EcoFlow's official website to obtain the latest product information.
EN

Table Of Contents

Technical Specifications 1

Safety Instructions 2

EcoFlow App 3

Getting Started 3
System Overview 3
Product Overview 7
CAN Bus Connection 8

Product Usage 9

Power On/Off 9
DC Output 9

AC Output 10

AC Charging 10

Smart Generator Charging 11

Solar Charging 12
Vehicle Alternator Charging 12
X-Boost Feature 13

Bypass Mode 14
Inverter Mode 14
Standby Mode 15

FAQs 15

What's in the Box 16

Care and Maintenance 17

FCC Statement 17
EN

Technical Specifications
Basic Information
Net Weight 14 kg (31 lbs)

Dimensions (L × W × H) 480 mm × 140 mm × 300 mm (18.9" x 5.5" x 11.8")

Wi-Fi Supported (<120 Meters)

Bluetooth (v4.0) Supported (<15 Meters)

Output Spec
Pure sine wave, 3600 W (surge 7200 W, 100 ms), 120 V, 60 Hz
Linear derating to 1800 W when 40℃ (104°F) < Ambient
AC Main Out
Temperature < 60℃ (140°F)
Derating to 3000 W when battery voltage < 49 V
AC Standard Out 120 V 20 A
Maximum AC Output
5200 W
Supported by X-Boost
13.6 V 70 A, maximum power: 1000 W
DC Output
or 26.4 V 60 A, maximum power: 1600 W

Input Spec
3000 W maximum power, 30 A maximum current, supported
AC Input Power
by EcoFlow X-Stream Technology
AC Input Voltage 100–120 V, 50 Hz/60 Hz

PV Input 2/3 15–60 V 30 A, maximum power: 1600 W

Alternator Input 1 13–60 V 60 A, maximum power: 1600 W


PV Input 1 15–60 V 30 A, maximum power: 1600 W

Battery Port Spec


40-60 V 100 A, supports up to three 2kWh or 5kWh LFP
batteries, which are sold separately.(Not recommended to
Battery Port (x3) use one Power Hub with both EFM100-BPB and EFM100-BP
at the same time.)

Operating Environment
Operating Temperature –25°C to 60°C (-13°F to 140°F)
Storage Temperature –25°C to 60°C (-13°F to 140°F)

Other
EcoFlow Smart Generator 1800 W maximum charging power, sold separately.

1
EN

Safety Instructions
1. SAVE THESE INSTRUCTIONS – This manual contains important safety and operating
instructions
2. This is a Safety Class I product (supplied with a protective grounding terminal).
Uninterruptible protective grounding must be provided at the AC input and/or output
terminals. Alternatively, the grounding point located externally on the product may
be used. Whenever it is likely that the grounding protection has been damaged, the
product must be turned off and secured against unintended operation; please contact
qualified service staff.
3. To prevent fire, short circuits, and electric shocks, do not install this product in
environments with high humidity, high temperature, or conductive contaminants.
4. Before installing this product, disconnect the main power supply. Do not work with
live power.
5. Keep this product away from heat sources, such as fires or heating furnaces.
6. Keep this product away from any liquid. Do not immerse this product in water or get it
wet. Do not use this product in rain or humid environments.
7. Do not use this product in environments with strong static electricity or magnetic fields.
8. Do not disassemble this product in any way or pierce it with sharp objects.
9. Do not use wires or other metal objects that may result in a short circuit.
10. Do not use unofficial components or accessories. If components or accessories need
to be replaced, purchase them from the EcoFlow official sales channels.
11. Strictly comply with the ambient temperature for use in this user manual when using
this product.
12. Do not stack other heavy objects on this product.
13. Do not forcibly block the fan during product use or place the product in an unventilated
or dusty area.
14. Please avoid impact, falls, or severe vibrations when using the product. In case of a
severe external impact, turn off the power supply immediately and stop using the
product. Ensure the product is well fastened during transportation to avoid vibrations
and impacts.
15. If the product falls into water accidentally during use, place it in a safe open area and
stay away from it until it is completely dry. The dried product cannot be reused, and
should be properly disposed according to the method described in the EcoFlow
Battery User Manual. If the product catches fire, we recommend that you use the
fire extinguishers in the following order: water or water mist, sand, fire blanket, dry
powder , and carbon dioxide fire extinguisher.
16. If there is dirt on the ports of the product, clean it with a dry cloth.
17. Place this product carefully to prevent damage caused by the product falling over. If
the product falls over and is seriously damaged, power it off immediately.
18.Proper disposal of batteries is required. Refer to your local local codes for disposal
requirements.
19. DANGER:To reduce the risk of fire or electric shock, carefully follow these instructions.
20. WARNING: A battery can present a risk of electrical shock, burn from high short-circuit
current, fire or explosion from vented gases. Observe proper precautions.
21. CAUTION : To ensure the safety, AC plug that will be connected Mains or Generator
shall comply UL498 certificated and no less than 38A.
22. Keep this product out of reach of children and pets.

2
EN

EcoFlow App

Control, monitor and customize your Power Kits from afar with the
EcoFlow App. Download at:
https://download.ecoflow.com/app

Privacy Policy
By using EcoFlow Products, Applications and Services, you consent to the EcoFlow Term
of Use and Privacy Policy, which you can access via the “About” section of the “User” page
on the EcoFlow App or on the official EcoFlow website at https://www.ecoflow.com/policy/
terms-of-use and https://www.ecoflow.com/policy/privacy-policy

1. The product Bluetooth can only be connected with one account, if you want
to use another account, please reset Bluetooth via the EcoFlow App or long
pressing the DC button on the product for 3 seconds.
2. This product ONLY SUPPORTS 2.4GHz WiFi.

Getting Started
System Overview

1. If the product is installed in an enclosed space, proper ventilation is a MUST


to prevent this product from overheating.
2. For safety reasons, it is recommended to install a Ground Fault Circuit
Interrupter (GFCI), also known as Residual Current Device (RCD) in the
AC input and AC output of the Power Hub. Please refer to local regulations
regarding grounding of autonomous power systems.
3. Before connecting this product to EcoFlow LFP Battery, ensure that there is
no charging input connected to Power Hub and LFP Battery is powered off.
4. It is not recommended to use one Power Hub with both EFM100-BPB and
EFM100-BP at the same time.
5. It is not recommended to connect or disconnect LFP battery when the
system is on.

3
EN
Recreational Vehicle (RV)
10
9 3
Fuse-100A
DC Appliance
(Not included)

1 2 > ≤
AC Appliance

Chassis

Engine Alternator
Starter Battery

Shore Power Inlet


8 (Not Included)

4 4 5 6

DC Appliance
Off Grid Builds / Self Consumption
AC Appliance

> ≤

4
EN
Partial Home Backup

Backup Loads

AC/DC Smart Distribution Panel AC Sub Panel


(Not Included)

> ≤ OR

Main Panel
(Not Included)
4

Home Loads
4

4
Utility Meter GRID
(Not Included)

1. EcoFlow Power Hub 6. Shore Power/Grid Power


2. AC/DC Smart Distribution Panel 7. Rigid/Flexible Solar Panel
3. Power Kit Console 8. Foldable / Portable Solar Panel
4. EcoFlow 2kWh/5kWh LFP Battery 9. Vehicle Alternator
5. EcoFlow Smart Generator 10. Fuse-100A (Not included)

5
EN
Whole Home Backup

This product can be connected to EcoFlow Smart Home Panel via "Power Hub Infinity Cable
to Smart Home Panel". Once connected, the AC input of the Power Hub is disabled and
the AC charging and discharging is controlled by the Smart Home Panel. The output of the
Power Hub can be turned on/off by pressing the AC switch button (marked as "AC 1" or "AC
2") on the Smart Home Panel. This scenario is used for home power backup or emergency
power for critical equipment, and supports AC parallel or split phase output.

Main Panel Smart Home Panel


(Not Included) (Sold Separately)
Utility Meter Whole
(Not Included)
GRID Home Backup

Power Hub Infinity Cable


To Smart Home Panel
(Sold separately)

4 4

4 4

4 4

6
EN

Product Overview

13 12 11 10

8
7 14

15

16
6

17

1 2 3 4 5

18

19

1. ALT IN / PV IN1 Port 7. DC OUT Button 14. RJ45 CAN Bus Ports
2. PV IN / ALT IN 2/3 Port 8. AC OUT Button 15. DC Main OUT Port
3. Battery 1/2/3 Port / 9. AC Out Indicator 16. AC Main OUT Port
Smart Generator Port 10. DC Out Indicator 17. Earth Stud
4. AC IN Port 11. AC In Indicator 18. Air Outlet
5. AC OUT Port (20A) 12. PV IN Indicator 19. Air Inlet
(For EFM100-HUB only) 13. ALT IN Indicator
6. Main Power Button

7
EN

CAN Bus Connection

To ensure communication quality, this product comes with two RJ45 CAN Bus ports, each
port can be connected to AC/DC Smart Distribution Panel, Power Kit Console, or RJ45 CAN
bus terminator. Both ports MUST be connected to stabilize communication throughout
the system. Not doing so will cause the system to malfunction.

> ≤

> ≤

8
EN

Product Usage
Power On / Off

3s

Status Indicators (Top right corner) Main Power Indicator


Five indicators illuminated in a sequence
Power-on Breathing
from left to right
Power-off Five indicators flash 3 times and stay off. Off

1. Please wait 5 seconds to let the system completely shut down before further
operation after pressing the main power button.
2. Ensure that there is no charging input connected to the Power Hub before
shutting down the Power Kits.

DC Output

When the power is on, short press the DC button to enable DC Output. To disable DC
Output, short press the DC button.

DC OUT: White
light stays on
Error: Orange
light flashing

9
EN

AC Output
When the power is on, short press the AC button to enable AC Output. To disable AC Output,
short press the AC button again.
When Power Hub is in idle mode, please turn off AC Output to avoid power loss.

AC OUT: White
light stays on
Error: Orange
light flashing

AC Charging
The EcoFlow Power Hub features EcoFlow fast charging technology X-Stream . The
maximum AC charging power is 3000 W and the maximum AC charging current is 30 A.
User can adjust the charging current via EcoFlow App or Power Kit Console. The default
charging current is 15 A.

Charging: White light flashing


Fully charged: White light stays on
Error: Orange light flashing

Shore Power Inlet


(not included)

EcoFlow is not liable for damages caused by the use of charging cables not
provided by EcoFlow.

10
EN

Smart Generator Charging


The Power Kits can be recharged by using different cables connected to the AC or DC
output of the EcoFlow Smart Generator.

DC Charging
Connect EcoFlow Smart Generator to the Power Hub with the Smart Generator Charging
Cable (Smart Generator, DC charging cable and adapter are sold separately).

AC Charging
Connect EcoFlow Smart Generator to the Power Hub with the AC Charging Cable.

(AC plug varies in different countries


and regions)

(Included in Cable Pack without AC plug)

11
EN

Solar Charging
The Power Hub has three PV (Photovoltaic) input ports, with a total power of 4800 W for
the three ports and 1600 W for each port. Any brand of solar panel can be used as long as
it meets the specifications of the solar charging input. For EcoFlow 100w rigid or flexible
solar panel, up to 6S3P can be connected to each port, for EcoFlow 400w rigid solar panel,
up to 4S1P or 2S2P can be connected to each port, for EcoFlow 400w foldable solar panel,
up to 3S1P or 2S2P can be connected to each port. (S: series, P: parallel)

PV3 Port
PV2 Port
PV1 Port

Charging: White light flashing


Fully charged: White light stays on
Error: Orange light flashing

Vehicle Alternator Charging


The Power Hub has three alternator charging input which supports 12V, 24V or 48V
alternator. Each port will draw 1600W Max, The max charging current of ALT IN1 Port
is 60 A, while the other two is 30 A. Only ALT IN1 charging current can be adjusted via
EcoFlow App or Power Kit Console.
It is strongly recommended to UNPLUG the alternator charging cable from the
Power Hub when vehicle is not in use for a long time.

Fuse-100A (Not included)

Charging : White light flashing


Fully charged : White light stays on
Error : Orange light flashing

12
EN

Vehicle Alternator System Vehicle Alternator Voltage


Alternator charging will
12V <13V
stop to protect vehicle
24V <26V starter battery from
48V <52V over-discharging

1. Vehicle Alternator Charging will only operate when vehicle is on move. If idle
charging is needed, user can toggle the idle charging button via EcoFlow APP.
2. Connect ALT IN1 port as a priority for vehicle alternator charging.

Priority of multiple charging


Power Hub supports multiple charging input simultaneously, and the charging
priorities are: solar charging, AC charging, vehicle alternator charging and EcoFlow
smart generator charging.
The total charging current at the battery port of the Power Hub is limited to 100A.
When the charging input power is greater than the power required by the battery,
the charging input with lower priority will reduce charging current smoothly or even
stop charging.

X-Boost Feature

With EcoFlow X-Boost technology, this product can power a 5200W Max device (for heating
appliances only) while the rated output power remains 3600W, avoiding operation failure
due to overload protection.

1. The X-Boost feature is unavailable when AC Output is in bypass mode.


2. The X-Boost feature is not suitable for all appliances. The X-Boost feature is
only suitable for heating appliances. It is not suitable for some appliances with
voltage protection, such as precision instruments.

13
EN

Bypass Mode
When the product is connected to external AC and the AC output is enabled, the system
enters bypass mode. The AC output is provided by the external AC power supply and the
LFP battery is charged by the external AC power supply.
When external AC is not available, the Power Hub will automatically transfer to inverter
mode, AC output will restore power within 30ms.

AC IN AC OUT

AC
DC

PV1 DC
DC
PV2 DC DC
DC DC OUT
DC
PV3 DC
DC

BATTERIES

Inverter Mode
When external AC power source is not available, the system will enter Inverter Mode. AC
Output is now supplied by the LFP battery.

AC IN AC OUT

AC
DC

PV1 DC
DC
PV2 DC DC
DC DC OUT
DC
PV3 DC
DC

BATTERIES

14
EN

Standby Mode

When the AC output and DC output of the product are continuously off and there is no
charging input for 20 seconds, it enters standby mode to reduce power consumption.
Pressing the DC OUT or AC OUT button can wake up the system.

The Power Hub will not enter Standby Mode during firmware update.

FAQs
1. Can I connect non-ECOFLOW photovoltaic panels?
Yes, the Power hub has three independent PV charging inputs, and users are free
to choose any brand and model of PV panel.
2. Which scenarios does this product apply to?
Application scenarios include but are not limited to Homes, RVs, and Off-grid Builds.
3. Do the input and output parameters of this product apply to electricity use
standards of all countries?
Yes. Both low-voltage and high-voltage versions of this product are available, which
cover electricity use standards of all countries.
4. What are the charging and discharging methods of this product?
Charging methods include: AC Charging, Vehicle Alternator Charging, Smart Generator
Charging and Solar Charging. The discharging method is AC/DC output.
5. Which devices can connect to the AC output port of this product?
The rated power of the AC output port of this product is 3600W, and surge power is
7200W. It can supply power to most home appliances. However, it is recommended to
confirm the power of the appliances before use, and ensure that the total power of all
AC loads is less than the rated power.
6. How can I clean this product?
Use a dry, soft, and clean cloth or paper towel to wipe off dust, dirt, or water on this
product.
7. How do I store this product?
Before storage, power off the product, then store it in a dry and well-ventilated indoor
environment. Do not place this product near water sources.

15
EN

What's in the Box


Power Hub ×1 Solar Charge Cable Mounting Kit (Back) ×1
(6m/20ft) ×1

Mounting Kit (Top / RJ-45 CAN Bus M4.8*25 (13 pcs)


Bottom) ×2 Terminator ×2

M5*10 (8 pcs) User Manual ×1


Warranty Card ×1
Quick Start Guide ×1

16
EN

Care and Maintenance


1. Use this product in an environment with a temperature ranging from -25°C (-13°F) to
60°C (140°F) and keep this product away from water sources, heat sources, and metal
objects.
2. For safety reasons, do not store this product in an environment where the temperature
is higher than 45°C (113°F) or lower than 0°C (32°F) for a long time.

FCC Statement
This equipment complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:

(1) This equipment may not cause harmful interference, and


(2) This equipment must accept any interference received, including interference that
may cause undesired operation.

Warning: Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.

FCC Radiation Exposure Statement:


This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
200 mm between the radiator & your body.

17

You might also like