IEC 62343-2
Edition 2.0 2014-07

INTERNATIONALE
INTERNATIONAL

Partie 2: Qualification de fiabilité


Part 2: Reliability qualification
STANDARD

Modules dynamiques –
Dynamic modules –
NORME
®
IEC 62343-2:2014-07(en-fr)
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
THIS PUBLICATION IS COPYRIGHT PROTECTED
Copyright © 2014 IEC, Geneva, Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form
or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from
either IEC or IEC's member National Committee in the country of the requester. If you have any questions about IEC
copyright or have an enquiry about obtaining additional rights to this publication, please contact the address below or
your local IEC member National Committee for further information.

Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de l'IEC ou du Comité national de l'IEC du pays du demandeur. Si vous avez des
questions sur le copyright de l'IEC ou si vous désirez obtenir des droits supplémentaires sur cette publication, utilisez
les coordonnées ci-après ou contactez le Comité national de l'IEC de votre pays de résidence.

IEC Central Office Tel.: +41 22 919 02 11


3, rue de Varembé Fax: +41 22 919 03 00
CH-1211 Geneva 20 info@iec.ch
Switzerland www.iec.ch

About the IEC


The International Electrotechnical Commission (IEC) is the leading global organization that prepares and publishes
International Standards for all electrical, electronic and related technologies.
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.

IEC Catalogue - webstore.iec.ch/catalogue Electropedia - www.electropedia.org


The stand-alone application for consulting the entire The world's leading online dictionary of electronic and
bibliographical information on IEC International Standards, electrical terms containing more than 30 000 terms and
Technical Specifications, Technical Reports and other definitions in English and French, with equivalent terms in 14
documents. Available for PC, Mac OS, Android Tablets and additional languages. Also known as the International
iPad. Electrotechnical Vocabulary (IEV) online.
IEC publications search - www.iec.ch/searchpub IEC Glossary - std.iec.ch/glossary
The advanced search enables to find IEC publications by a More than 55 000 electrotechnical terminology entries in
variety of criteria (reference number, text, technical English and French extracted from the Terms and Definitions
committee,…). It also gives information on projects, replaced clause of IEC publications issued since 2002. Some entries
and withdrawn publications. have been collected from earlier publications of IEC TC 37,
77, 86 and CISPR.
IEC Just Published - webstore.iec.ch/justpublished
Stay up to date on all new IEC publications. Just Published IEC Customer Service Centre - webstore.iec.ch/csc
details all new publications released. Available online and If you wish to give us your feedback on this publication or
also once a month by email. need further assistance, please contact the Customer Service
Centre: csc@iec.ch.

A propos de l'IEC
La Commission Electrotechnique Internationale (IEC) est la première organisation mondiale qui élabore et publie des
Normes internationales pour tout ce qui a trait à l'électricité, à l'électronique et aux technologies apparentées.
A propos des publications IEC
Le contenu technique des publications IEC est constamment revu. Veuillez vous assurer que vous possédez l’édition la
plus récente, un corrigendum ou amendement peut avoir été publié.
Catalogue IEC - webstore.iec.ch/catalogue Electropedia - www.electropedia.org
Application autonome pour consulter tous les renseignements
Le premier dictionnaire en ligne de termes électroniques et
bibliographiques sur les Normes internationales, électriques. Il contient plus de 30 000 termes et définitions en
Spécifications techniques, Rapports techniques et autres anglais et en français, ainsi que les termes équivalents dans
documents de l'IEC. Disponible pour PC, Mac OS, tablettes
14 langues additionnelles. Egalement appelé Vocabulaire
Android et iPad. Electrotechnique International (IEV) en ligne.
Recherche de publications IEC - www.iec.ch/searchpub
Glossaire IEC - std.iec.ch/glossary
La recherche avancée permet de trouver des publications IEC Plus de 55 000 entrées terminologiques électrotechniques, en
en utilisant différents critères (numéro de référence, texte, anglais et en français, extraites des articles Termes et
comité d’études,…). Elle donne aussi des informations sur les Définitions des publications IEC parues depuis 2002. Plus
projets et les publications remplacées ou retirées. certaines entrées antérieures extraites des publications des
CE 37, 77, 86 et CISPR de l'IEC.
IEC Just Published - webstore.iec.ch/justpublished
Service Clients - webstore.iec.ch/csc
Restez informé sur les nouvelles publications IEC. Just
Published détaille les nouvelles publications parues. Si vous désirez nous donner des commentaires sur cette
Disponible en ligne et aussi une fois par mois par email. publication ou si vous avez des questions contactez-nous:
csc@iec.ch.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2
®
Edition 2.0 2014-07

INTERNATIONAL
STANDARD
NORME
INTERNATIONALE

Dynamic modules –
Part 2: Reliability qualification

Modules dynamiques –
Partie 2: Qualification de fiabilité

INTERNATIONAL
ELECTROTECHNICAL
COMMISSION

COMMISSION
ELECTROTECHNIQUE
INTERNATIONALE PRICE CODE
CODE PRIX S
ICS 33.180 ISBN 978-2-8322-1799-3

Warning! Make sure that you obtained this publication from an authorized distributor.
Attention! Veuillez vous assurer que vous avez obtenu cette publication via un distributeur agréé.

® Registered trademark of the International Electrotechnical Commission


Marque déposée de la Commission Electrotechnique Internationale
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
–2– IEC 62343-2:2014 © IEC 2014

CONTENTS

FOREWORD ........................................................................................................................... 3
1 Scope .............................................................................................................................. 5
2 Normative references ...................................................................................................... 5
3 Terms, definitions and abbreviations ............................................................................... 6
3.1 Terms and definitions .............................................................................................. 6
3.2 Abbreviated terms ................................................................................................... 6
4 Reliability qualification considerations ............................................................................. 7
4.1 General ................................................................................................................... 7
4.2 General consideration approach ............................................................................. 7
4.3 DM product design .................................................................................................. 7
5 Reliability qualification requirements................................................................................ 7
5.1 General ................................................................................................................... 7
5.2 Demonstration of product quality ............................................................................. 8
5.3 Testing responsibilities ........................................................................................... 8
5.4 Tests ...................................................................................................................... 9
5.4.1 Thorough characterization ............................................................................... 9
5.4.2 Reliability qualification of components, parts and interconnections .................. 9
5.4.3 Reliability qualification of DM assembly process .............................................. 9
5.4.4 Reliability qualification of the Design 1 DM ...................................................... 9
5.4.5 Reliability qualification of the Design 2 DM .................................................... 11
5.4.6 Pass/fail criteria ............................................................................................. 13
5.5 Reliability assessment procedure .......................................................................... 13
5.5.1 Analysis of reliability results .......................................................................... 13
5.5.2 Reliability calculations ................................................................................... 13
5.5.3 Reliability qualification test methods .............................................................. 14
6 Guidance – FMEA and qualification-by-similarity ........................................................... 14
Annex A (informative) Reliability test items and their conditions .......................................... 16
A.1 General ................................................................................................................. 16
A.2 Mechanical environment tests ............................................................................... 16
A.3 Temperature and humidity environmental tests ..................................................... 17
A.4 Electromagnetic compatibility tests ....................................................................... 17
A.5 Fibre integrity tests ............................................................................................... 18
Bibliography .......................................................................................................................... 20

Table 1 – Minimum list for tests required on Design 1 DMs ................................................... 10


Table 2 – Minimum list for tests required on Design 2 DMs ................................................... 12
Table 3 – Failure rate of parts ............................................................................................... 14
Table 4 – Relevant list of IEC reliability test methods for optical components ........................ 14
Table A.1 – Mechanical environmental tests and severity ..................................................... 16
Table A.2 – Temperature and humidity tests and severity ..................................................... 17
Table A.3 – Electromagnetic compatibility test items and their severities .............................. 18
Table A.4 – Fibre integrity test items and their severities ...................................................... 19
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 –3–

INTERNATIONAL ELECTROTECHNICAL COMMISSION


____________

DYNAMIC MODULES –

Part 2: Reliability qualification

FOREWORD
1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising
all national electrotechnical committees (IEC National Committees). The object of IEC is to promote
international co-operation on all questions concerning standardization in the electrical and electronic fields. To
this end and in addition to other activities, IEC publishes International Standards, Technical Specifications,
Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC
Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested
in the subject dealt with may participate in this preparatory work. International, governmental and non-
governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely
with the International Organization for Standardization (ISO) in accordance with conditions determined by
agreement between the two organizations.
2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international
consensus of opinion on the relevant subjects since each technical committee has representation from all
interested IEC National Committees.
3) IEC Publications have the form of recommendations for international use and are accepted by IEC National
Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC
Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any
misinterpretation by any end user.
4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications
transparently to the maximum extent possible in their national and regional publications. Any divergence
between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in
the latter.
5) IEC itself does not provide any attestation of conformity. Independent certification bodies provide conformity
assessment services and, in some areas, access to IEC marks of conformity. IEC is not responsible for any
services carried out by independent certification bodies.
6) All users should ensure that they have the latest edition of this publication.
7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and
members of its technical committees and IEC National Committees for any personal injury, property damage or
other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and
expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC
Publications.
8) Attention is drawn to the Normative references cited in this publication. Use of the referenced publications is
indispensable for the correct application of this publication.
9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of
patent rights. IEC shall not be held responsible for identifying any or all such patent rights.

International Standard IEC 62343-2 has been prepared by subcommittee 86C: Fibre optic
systems and active devices, of IEC technical committee 86: Fibre optics.

This second edition cancels and replaces the first edition published in 2011 and constitutes a
technical revision. The main change with respect to the previous edition is the addition of
Annex A (informative), Reliability test items and their conditions.

The text of this standard is based on the following documents:

CDV Report on voting


86C/1185/CDV 86C/1248/RVC

Full information on the voting for the approval of this standard can be found in the report on
voting indicated in the above table.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
–4– IEC 62343-2:2014 © IEC 2014

This publication has been drafted in accordance with the ISO/IEC Directives, Part 2.

A list of all parts in the IEC 62343 series, published under the general title Dynamic modules,
can be found on the IEC website.

The committee has decided that the contents of this publication will remain unchanged until
the stability date indicated on the IEC web site under "http://webstore.iec.ch" in the data
related to the specific publication. At this date, the publication will be

• reconfirmed,
• withdrawn,
• replaced by a revised edition, or
• amended.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 –5–

DYNAMIC MODULES –

Part 2: Reliability qualification

1 Scope

This part of IEC 62343 applies to dynamic modules and devices (DMs) which are
commercially available. Examples are tuneable chromatic dispersion compensators,
wavelength selective switches and optical channel monitors.

Optical amplifiers are not included in this list, but are treated in IEC 61291-5-2.

For reliability qualification purposes, some information about the internal components, parts
and interconnections is needed; these internal parts are treated as black boxes. This standard
gives requirements for the evaluation of DM reliability by combining the reliability of such
internal black boxes.

The objectives of this standard are the following:

• to specify the requirements for the reliability qualification of DMs;


• to give the minimum list of reliability qualification tests, requirements on failure criteria
during testing and on reliability predictions, and give the relevant normative references.

2 Normative references

The following documents, in whole or in part, are normatively referenced in this document and
are indispensable for its application. For dated references, only the edition cited applies. For
undated references, the latest edition of the referenced document (including any
amendments) applies.

IEC 61300-2-1, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-1: Tests – Vibration (sinusoidal)

IEC 61300-2-4, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-4: Tests – Fibre/cable retention

IEC 61300-2-12, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-12: Tests – Impact

IEC 62005-9-1, Fibre optic interconnecting devices and passive components – Reliability –
Part 9-1: Qualification of passive optical components 1

IEC 62005-9-2, Reliability of fibre optic interconnecting devices and passive optical
components – Part 9-2: Reliability qualification for single fibre optic connector sets – Single
mode

IEC 62572 (all parts), Fibre optic active components and devices – Reliability standards

ISO 9000: Quality management systems – Fundamentals and vocabulary

___________
1 To be published.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
–6– IEC 62343-2:2014 © IEC 2014

3 Terms, definitions and abbreviations

3.1 Terms and definitions

For the purposes of this document, the following terms and definitions apply.

3.1.1
failure
non-compliance to product specification or change in parameters as set by the standard or
agreed by the customer and supplier

3.1.2
qualification
commonly used as the abbreviation for reliability qualification

Note 1 to entry: It is used as a formal testing to determine whether or not the product is suitable for telecom
applications and, therefore, “pass or fail” is the expected outcome

Note 2 to entry: This is different from a reliability test, which is in nature a reliability “engineering test”. Reliability
tests are designed to understand the reliability consideration or estimate the reliability of the product. Pass or fail is
not the main output.

3.1.3
reliability
< time period > minimum period of DM continuous operation without failure at specified
operating and environmental conditions

3.1.4
<reliability
<probability> probability to perform required functions at specified operating and
environmental conditions

Note 1 to entry: The reliability of a DM is expressed by either of the following two parameters: mean time between
failure (MTBF) and failures in time (FIT):
• the MTBF is the mean period of DM continuous operation without any failure at specified operating and
environmental conditions;
• the FIT is the number of failures expected in 10 9 device-hours at specified operating and environmental
conditions.

3.2 Abbreviated terms


DM dynamic module
DS detail specification
ESD electrostatic discharge
FIT failure in time
FMEA failure mode and effects analysis
LCD liquid crystal device
MTBF mean time between failure
RH relative humidity
UCL upper confidence level
VOA variable optical attenuators
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 –7–

4 Reliability qualification considerations

4.1 General

Since DMs are relatively new products in the commercial market and involve different
technologies, the requirements included in this standard will need to be reviewed as
technology progresses.

4.2 General consideration approach

It is worth emphasizing the fundamental approach of reliability qualification adopted in this


standard:

a) Any parts that can be effectively qualified on their individual levels shall be qualified at
that level. Their qualification shall be based on IEC standards or other industrial
standards in the absence of such IEC standards.
b) The qualification tests required at DM level shall be based on the degradation
mechanisms and failure modes that cannot be effectively detected in the lower part levels.
At the DM level, the qualification tests shall not attempt to discover or identify those
degradation mechanisms and failure modes that can be discovered in the lower assembly
levels than the final product level. For example, if all parts in the DM can be effectively
tested for damp heat-accelerated degradations, there is no need to repeat the damp heat
test at the DM level.

4.3 DM product design

A DM is an assembly of various components, parts and interconnections. There are two basic
designs in the current commercial DM market:

a) Design 1: parts (as a general term that includes components, parts and interconnections
used to build a DM from the of point of view of this standard) are packaged separately.
Their packages are usually either hermetic or moisture-resistant. They are integrated into
a housing (usually non-hermetic or not moisture-resistant).
b) Design 2: some parts used in DMs are unpackaged basic optical elements (e.g. crystals,
lenses, mirrors, etc.). These parts cannot be effectively qualified by themselves. These
parts/elements are integrated and packaged inside a hermetic box or moisture-resistant
box.

In Design 1, the individual parts can be tested and qualified individually and therefore, the DM
qualification does not have to repeat the tests that are performed in the part levels for the
same degradation mechanisms and failure modes.

In Design 2, the DM qualification is again focused on the tests that cannot be effectively
performed in the lower assembly levels (i.e., the basic part level). However, in this case there
are usually more tests required since the parts cannot be effectively tested at the part level
individually.

Due to the differences in the designs, and therefore different mechanisms and failure modes,
different qualification test approaches have to be developed separately. They are described in
5.4.4 for Design 1 and 5.4.5 for Design 2, respectively.

5 Reliability qualification requirements

5.1 General

For the purpose of this standard, each internal component, part and interconnection shall be
treated as a black box. It is also important to point out that the parts in the DM of this design
include the fibre splicing, fibre routing and fibre anchoring, as well as how the fibre exits from
the housing and how parts are mounted.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
–8– IEC 62343-2:2014 © IEC 2014

This standard is based on the assumption that the reliability of a DM can be evaluated with
sufficient confidence from the FIT rates of its internal black boxes when the assembly process
of the constituents has been qualified.

There are degradation and failures not due to part failures. An example is the fibre routing
and fibre holders. The quality and reliability of the assembling, for example fibre routing, shall
be assessed and qualified through the process evaluation and qualification. The procedures
to qualify the assembly process are described in 5.4.3.

The internal black boxes often constituting a DM are listed below:

• passive optical components, including patch cords, pigtails, connectors and splices;
• active optical components;
• electronics, including PCBs, electrical connectors, etc.
• others (e.g. fibre splicing, fibre routing and fibre anchoring, as well as how the fibre exits
from the housing and how components are mounted).

The DM manufacturers shall declare the number and type of the internal black boxes
constituting the DM and give the failure rates (in FITs) for each black box.

The DM failure rate shall be calculated by suitably combining the failure rates in FITs of its
black boxes, as described in the 5.5.2. The model and assumptions used in DM failure rate
calculation shall be provided and justified for review, if the DM manufacturer has so requested.

5.2 Demonstration of product quality

Since the reliability qualification tests are performed on a limited number of units, it is
essential to have a quality management system in place to assure that the quality of all units
is consistent. Testing on a limited number of samples will be representative of the production
units to be delivered after the qualification is completed.

This standard (where required by the detailed specification) specifies the minimum mandatory
requirements to assess reliability qualification of a DM and is intended to be part of a total DM
reliability program and quality management system developed and implemented by the DM
manufacturer.

The DM manufacturer shall demonstrate:

• a documented and audited manufacturing process, including the reliability qualification of


purchased parts, in accordance with ISO 9000;
• performance data of production units shall be available for review, and its distribution shall
show processes are under adequate controls;
• a reliability qualification programme, including, for example, accelerated life testing, burn-
in and screening of parts and DMs;
• a reliability qualification maintenance programme to ensure continuity of qualification
status (this can be achieved by means of periodic reliability qualification tests of the
product or similar products);
• a procedure to ensure an appropriate feedback to development and production on
reliability issues.

5.3 Testing responsibilities

The DM manufacturer is responsible for performing reliability qualification testing.

The testing detailed in this standard shall be performed by the DM manufacturer. Additional
testing may be specified in the detailed specification.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 –9–

5.4 Tests

5.4.1 Thorough characterization

A thorough characterization of the product for its performance (may be beyond those in the
performance specifications) and overall operating conditions (may be beyond those in the
operating condition specifications) shall be performed. The data shall be collected and
analysed (minimal for the mean and standard deviation), and be available for review.

5.4.2 Reliability qualification of components, parts and interconnections

All components, parts, and interconnections used to build DMs shall be qualified according to
the appropriate IEC standards for each of them. The components may include, but are not
limited to, variable optical attenuators (VOAs), taps/splitters, detectors, isolators, circulators,
electronic components, splicing connections (including the packaging or re-coating), crystals,
mirrors, prisms, etc.

If the IEC standards for the parts are under development or not yet available, the IEC
standards for parts of similar failure modes and degradation mechanisms should be adopted.
An analysis of similarity of failure modes and degradation mechanisms shall be provided to
support the approach.

Considerations shall be given to designs that use many pieces of same parts. The failure
rates of such parts may significantly contribute to the overall system failure rate or downtime.
The cumulative degradation from individual parts should also be investigated. The results may
require tests on additional samples or more stringent failure definitions.

Additionally, the pass/fail criteria of the part qualification shall be thoroughly examined to
determine whether or not the part qualification is adequate. For an example, if several 1x2
taps are used in a series design, not only the failure rate but also the degradation is multiplied
(i.e. 0,5 dB pass/fail criterion is multiplied), which may not be acceptable. The pass/fail
criterion of the parts commonly defined as 0,5 dB changes in insertion loss is much too loose
for the needs of a product such as a DM. The assessment of tighter criteria shall be carried
out and the qualification status justified.

5.4.3 Reliability qualification of DM assembly process

Fibre routing and component mounting are both important module assembling processes, and
they can be significant failure rate contributors if they are not done properly. Their designs
and processes shall be thoroughly documented and tested. Any changes shall be supported
by adequate experiment data.

If the fibre routing is thoroughly documented and controlled (e.g. through performance
measurements before and after routing) and the final DM is qualified, the fibre routing process
can be considered as a qualified process and can be used in other similar products to
produce a product that is claimed to be qualified by similarity.

5.4.4 Reliability qualification of the Design 1 DM

As described in 5.1 for Design 1, parts (components used to build a DM) are packaged
separately. Their packages are usually either hermetic or moisture-resistant. They are
integrated into a housing (usually non-hermetic or not moisture-resistant).

A reliability qualification procedure related to the complete DMs is described in Table 1. It


gives the minimum list of tests to be performed on DMs in order to assure reliability.

For the tests, no failures are allowed. The tests can be performed sequentially or in parallel.
For “operational” tests, relevant parameters should be monitored during the test.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 10 – IEC 62343-2:2014 © IEC 2014

On the basis of the reliability assurance required for the reliability tests for the DM internal
black boxes, the sampling level is generally low (for example a few samples for each DM
type).

In some specific cases the use of adhesives in the DM can be considered as a critical process
and shall require separate qualification. Depending on the possible function of the adhesive
(mechanical anchoring, splice protection, index matching, etc.), the different failure modes
shall be addressed and supported by reliability/qualification data.

The main point in the reliability qualification of the Design 1 DMs is to ensure that the
reliability of each part is not degraded in the manufacturing process used.

Table 1 – Minimum list for tests required on Design 1 DMs

Test Condition Duration Samples


Active high temperature aging 85 °C 2 000 h 3
T op, min /T op, max
Operational temperature cycling 100 cycles 3
>1 °C/min
100 mm height drop for
Drop (impact) a <10 kg, 75 mm drop for 10 See table below 3
kg − 25 kg
Non-operational
mechanical test b 10 Hz to 55Hz, 1,52 mm,
Vibration 2 h per direction 3
1 octave/min
c
Pull 5/10/100 N See table below 3
2,
400 m/s 5ms for
+/- z-axis,

d 200 m/s 2 , 5ms for


Operational shock 3 times/direction 3
+/- x-axis,
100 m/s 2 , 5 ms for
+/- y-axis
50 Hz to 500 Hz,
20 m/s 2 for z-axis,
d
Operational vibration 2 sweeps/direction 3
10 m/s 2 for x-axis,
5 m/s 2 for y-axis
NOTE A reference to the temperature cycle test method is provided in Clause A.3.
a Mechanical test: Impact (drop) (IEC 61300-2-12 for drop)
Mass Drop height
kg mm
0 to < 10 100

10 to < 25 75
b Mechanical test: vibration(sinusoidal, IEC 61300-2-1).
c Pigtail testing (pull test). The first figure in each row is the outer diameter of the buffered or cabled fibre to
which the specified test conditions apply.
2 mm: 20 N to100 N, 3 times, 5 s pulls
Cable
retention 900 µm 10 N, 3 times, 5 s pulls IEC 61300-2-4
(pull)
250 µm: 5 N, 3 times, 5 s pulls
d The directions of the x, y and z axes are defined by mounting direction to a board in a equipment (x-axis: the
direction which is according to the front and back of the board to be mounted when the board is installed in a
piece of equipment; y-axis: the direction which is according to the gravity (up and down) of the board to be
mounted when the board is installed in a piece of equipment; z-axis: the direction which is perpendicular to
the board to be mounted.) If a tester cannot define the mounting direction, the test shall be carried out in the
most severe conditions for all directions.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 11 –

It is essential that the evaluated DMs are entirely representative of standard production and
have passed all the production procedures and/or specified (where applicable in the DS) burn-
in and screening procedures.

Aspects of the test conditions not provided in the present standard are given in the relevant
detail specifications.

5.4.5 Reliability qualification of the Design 2 DM

A reliability qualification procedure related to design 2 DMs is described in Table 2. In this DM


design, Design 2, not all parts can be effectively tested by themselves (see 4.3). Therefore,
many of the long-term environmental tests can only be effectively tested and qualified in the
DM final product assembly level.

For the test, no failures are allowed. The tests can be performed sequentially or in parallel.
For “operational” tests, relevant parameters should be monitored during the test.

For example, some of the parts may have been qualified by the damp heat test but others
may not pass the damp heat test as required for telecommunications applications. Therefore,
the DM units with all the parts assembled shall be tested in damp heat conditions. This may
seem redundant, but it is necessary.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 12 – IEC 62343-2:2014 © IEC 2014

Table 2 – Minimum list for tests required on Design 2 DMs

Test Condition Duration Samples


Active high temperature aging 85 °C 2 000 h 3
T op, min /T op, max
Operational temperature cycling 100 cycles 3
>1 °C/min
Damp heat 85 °C/85 % RH a 500 h 3
100 mm height drop for
b
Drop (impact) <10 kg, and 75 mm drop See table below 3
for 10 kg – 25 kg
Non-operational
mechanical test c 10 Hz to 55 Hz,
Vibration 2 h per direction 3
1,52mm,1 octave/min
d
Pull 5/10/100 N See table below 3
400 m/s 2 ,
5ms for
± z-axis,

e 200 m/s 2 , 5ms for


Operational shock 3 times/direction 3
± x-axis,
100 m/s 2 , 5ms for
± y-axis
50 Hz to 500 Hz,
20 m/s 2 for z-axis
e
Operational vibration 2 sweeps/direction 3
10 m/s 2 for x-axis
5 m/s 2 for y-axis

Hermeticity (checked before and after 3


∆T = 100 °C 15 cycles
liquid-to-liquid thermal shock) dummy box
NOTE A reference to the temperature cycle test method is provided in Clause A.3.
a Damp heat: the damp heat test at 85 °C/85 % RH for 100 h has been advocated by some manufacturers.
These test conditions may be used. Otherwise, the damp heat test at 40 °C/93 % RH for a much longer
duration may be used with the actual duration to be determined by the acceleration factor.
b Mechanical test: impact (IEC 61300-2-12).
Mass Drop height
kg mm
0 to <10 100

10 to <25 75
c Mechanical test: vibration (sinusoidal, IEC 61300-2-1).
d Pigtail testing (pull test). The first figure in each row is the outer diameter of the buffered or cabled fibre to
which the specified test conditions do apply.
2 mm: 20 N to100 N, 3 times, 5 s pulls
Cable
retention 900 µm: 10 N, 3 times, 5 s pulls IEC 61300-2-4
(pull)
250 µm: 5 N, 3 times, 5 s pulls
e The direction of the x, y and z axes are defined by mounting direction to a board in a piece of equipment (x-
axis: the direction which is according to the front and back of the board to be mounted when the board is
installed in a piece of equipment; y-axis: the direction which is according to the gravity (up and down) of the
board to be mounted when the board is installed in a piece of equipment; z-axis: the direction which is
perpendicular to the board to be mounted.) If a tester cannot define the mounting direction, the test shall be
done in the most severe conditions for all directions.

It is essential that the evaluated DMs are entirely representative of standard production and
have passed all the production procedures and/or specified (where applicable in the DS) burn-
in and screening procedures.

Aspects of the test conditions not provided in the present standard are given in the relevant
standards.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 13 –

5.4.6 Pass/fail criteria

It should be noted that the commonly used failure criterion of a drift of higher than 0,5 dB in
insertion loss (IL) is a guideline. For DWDM DMs, such as wavelength blockers, centre
wavelength drift shall be defined as a failure criterion. The actual and practical criteria should
be developed based on the degradation allowed for the expected life of the product. An
example is provided below to illustrate the determination.

EXAMPLE:

• The acceleration factor of the testing condition to the operating condition is 50.
• The beginning-of-life parametric measurement is 1,0 dB below the end-of-life specification.
• Assume the expected life is 20 years.
• Allowed degradation for a 2 000 h testing is: (1,0*50*2 000)/(20*365,25*24) = 0,57 dB.
• Note that IL is not the only parameter considered for pass/fail; other parameters are included.

5.5 Reliability assessment procedure

5.5.1 Analysis of reliability results

The DM customer/SS shall have a procedure to analyse and verify reliability claims of a DM
manufacturer. In particular, the procedure should include the analysis of

• life test data for the complete dynamic module,


• life test data for internal parts,
• environmental test results.

The analysis of results leads to reporting the reliability parameters of the DM for each type of
device or sub-system. Minimum reliability parameters shall be presented as in Table 4 (see
below).

5.5.2 Reliability calculations

A reliability prediction regarding the complete DM is provided by the DM manufacturer, based


on the failure rates (in FIT “failure in time”) of the internal black boxes composed of the DM
(Design 1) or based on the data for the complete DM (Design 2).

The failure rates of the internal black boxes shall be given by the DM manufacturer taking into
account the basic values issued from the cumulated component-hours issued from the
different parts included in DM. The calculations for each internal black box shall be based on
the current standards regarding reliability calculations.

The reliability calculations will also include the wear-out failures. The FIT figures given for
each internal black box shall take into account all expected failure modes.

The FIT figures of the internal black boxes shall be combined to give the failure rate of the
Design 1 DM as explained in Table 3.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 14 – IEC 62343-2:2014 © IEC 2014

Table 3 – Failure rate of parts

Number of
Element Measured value (UCL 95 %)
elements

Splice n2 A2 FIT (random failure)


Connector n3 A3 FIT (random failure)

Electronics n4 A4 FIT (random failure)

Active component type 1 n (4+1) A (4+1) FIT (random and wear-out failure)

Active component type 2 n (4+2) A (4+2) FIT (random and wear-out failure)

………………………………………… …………………………………………………
Active component type m n (4+m) A (4+m) FIT (random and wear-out failure)

Other internal component type 1 n (4+m+1) A (4+m+1) FIT (random failure)

Other internal component type 2 n (4+m+2) A (4+m+2) FIT (random failure)


………………………………………… ……………………………….
Other internal component type h n (4+m+h) A (4+m+h) FIT (random failure)

Passive optical component type 1 n (4+m+h+1) A (4+m+h+1) FIT (random failure)

Passive optical component type 2 n (4+m+h+2) A (4+m+h+2) FIT (random failure)

………………………………………… ……………………………….
Passive optical component type k n (4+m+h+k) A (4+m+h+k) FIT (wear-out failure)
Fibre routing
Optical component attachment n (4+m+h+k) A (4+m+h+k) FIT
Any other failure modes identified in
n (4+m+h+k) A (4+m+h+k) FIT
FMECA
Total failure rate ∑ i A i *n I
NOTE n i is the number of components of each type included in the DM.

5.5.3 Reliability qualification test methods

Table 4 shows a list of normative references relevant reliability qualification tests and test
conditions for constituting components used for DMs.

Table 4 – Relevant list of IEC reliability test methods for optical components

Constituting components IEC reference


(reliability qualification document number)
Passive optical components IEC 62005-9-1
Optical connectors IEC TR 62005-9-2
Active optical components IEC series 62572

6 Guidance – FMEA and qualification-by-similarity

It is worth emphasizing that the reliability assessment or qualification tests shall be based on
the degradation mechanisms and failure modes. The appropriate accelerated tests can be
developed once the degradation mechanisms, failure modes, and their acceleration factors
are understood. To begin with, the failure mode and effects analysis (FMEA) should be
developed. A set of reliability tests should be planned and conducted as the result of FMEA.
The testing results can be used to develop additional tests or refined tests to better
understand the degradation mechanisms or develop the acceleration models.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 15 –

Where a range of dynamic modules is produced by a DM manufacturer, there may be some


significant similarity between different type codes. A combination of results from different test
programmes, where appropriate, is therefore permitted.

Consideration should be given to the fact that minor differences in technology or processing
can sometimes have a major impact on reliability, whilst not being apparent during quality
assessment.

As a minimum, FMEA shall be carried out for all varieties of products that are considered
“similar” and claimed to be “qualified” by “similarity”. FMEA shall be carried out thoroughly in
order to be an effective tool to consider “qualified-by-similarity”. Its thoroughness can be
checked against the failure mode analysis (FMA), based on manufacturing drop-out and
customer returns.

Evidence should be presented which demonstrates that all results are directly relevant.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 16 – IEC 62343-2:2014 © IEC 2014

Annex A
(informative)

Reliability test items and their conditions

A.1 General

This annex provides information on reliability test items and conditions for DMs. The tester
can select reliability test items and conditions by referring to the following.

A.2 Mechanical environment tests

Table A.1 shows the severity of test items for the mechanical environmental tests. For a
dynamic module with moving parts, such as MEMS mirrors, it is strongly recommended to test
operating mechanical shock and vibration. Operating mechanical shock and vibration tests
are carried out by monitoring the performance of dynamic modules during the tests. The
transportation vibration and handling drop test should be carried out as packed modules.

Table A.1 – Mechanical environmental tests and severity

Groups Test items Severity References


Mechanical shock Mechanical shock 400 m/s 2 , 5 ms for ± z-axis IEC 62343-6-5
(operating) 200 m/s 2 , 5 ms for ± x-axis
100 m/s 2 , 5 ms for ± y-axis
3 times per each direction
Vibration Mechanical vibration 50 Hz – 500 Hz IEC 62343-6-5
(operating) 20 m/s 2 for z-axis
10 m/s 2 for x-axis
5 m/s 2 for y-axis
1 octave/min
2 sweeps per each direction
Mechanical Mechanical shock 5 000 m/s 2 , 3 axes, 2 impacts/direction GR-1209,
shock/impact (components) (12 impacts total) IEC 61753-1,
(non-operating) Nominal 1 ms, half sine pulse IEC 61300-2-9
(weight: ≤ 0,125 kg)
Mechanical shock 2 000 m/s 2 , 3 axes, 2 impacts/direction GR-1209,
(module) (12 impacts total), IEC 61753-1,
(non-operating) Nominal 1,33 ms, half sine pulse IEC 61300-2-9
(weight: > 0,125 and ≤ 0,225 kg)
500 m/s 2 , 3 axes, 2 impacts/direction GR-1209,
(12 impacts total) IEC 61753-1,
Nominal 5 ms, half sine pulse IEC 61300-2-9
(weight: >0,225 and≤ 1 kg)
Unpacked drop 100 mm height for ≤10 kg weight GR-63
(non-operating) 75 mm height for >10 kg and ≤ 25 kg weight
Mechanical Vibration 10 Hz – 55 Hz, 1,52 mm amplitude, 3 axes (20 GR-1209
vibration (non-operating) min/axis) for 1 h
Vibration 10 Hz – 5 Hz, 0,75 mm amplitude, 3 axes, 1 IEC 61753-1
(non-operating) octave/min, 15 sweeps per direction IEC 61300-2-1
Transportation Transportation 5 Hz – 20 Hz, 0,01 g 2 /Hz, 20 – 200 Hz, GR-63
mechanical vibration – packed –3 dB/octave
impact/vibration (non-operating)
Handling drop 1 m height for ≤10 kg weight GR-63
(non-operating)
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 17 –

A.3 Temperature and humidity environmental tests

Table A.2 shows the severity of test items for temperature and humidity environmental tests.
These kinds of tests are most common for design verification and reliability. For hermetically
sealed packaged modules, it may be possible to omit damp heat and high humidity tests. For
half-sealed (resin-sealed) modules, it should be noted that test modules may absorb moisture.
For hermetically sealed packaged modules, it is recommended to carry out an RGA (residual
gas analysis) test.

Table A.2 – Temperature and humidity tests and severity

Groups Test items Severity References


High temperature High temperature 60 °C ±2 °C, 96 h IEC 61753-1 cat C,
(non-operating) IEC 61300-2-18
Low temperature Low temperature –10 °C ±2 °C, 96 h IEC 61753-1 cat C,
(non-operating) IEC 61300-2-17
Temperature Temperature cycling –40 °C to 70 °C, 10 cycles, dwell time: GR-1209
cycling (non-operating) 12 min, ramp rate: 1 °K /min
Temperature Change of –10 °C ±2 °C to 60 °C ±2 °C, duration IEC 61753-1 cat C,
cycling temperature time: 60 min, 1 °K /min changing rate, IEC 61300-2-22
(operating) 5 cycles
DWDM temperature –10 °C to 60 °C, dwell time: 30 min GR-1209
effect
(operating)
Temperature shock Low temperature 30 °K/h to –40 °C, –40 °C for 72 h, GR-63
thermal shock 5 min to RT
(non-operating)
High temperature 30 °K/h to 70 °C, 70 °C for 72 h, GR-63
thermal shock 5 min to RT
(non-operating)
Damp heat Temperature 75 °C, 90 % RH, 168 h GR-1209
humidity aging
(non-operating)
Damp heat steady 40 °C ±2 °C, 93 % + 2 %, 96 h IEC 61753-1 cat C,
state −3
(non-operating) IEC 61300-2-19

High relative humidity 40 °C, 93 %, 96 h GR-63


(non-operating)
Damp heat steady 30 °C, 80 %, 96 h JIS C 5901
state
(non-operating)
Temperature Temperature –10 °C to 60 °C, humidity from 20 % GR-1209
humidity cycling humidity cycling RH to 85 % RH
(operating)

A.4 Electromagnetic compatibility tests

Table A.3 shows test items and severity of electromagnetic compatibility tests. For the
dynamic modules which use an LCD (liquid crystal device) as driving engine, an alternative
wave may be used by electrical driving voltage. A DC/AC convertor circuit may have an
impact on ESD and so on. For the dynamic module using an electrostatic MEMS engine inside,
a high voltage up-convertor circuit may be mounted. It is recommended to carry out ESD
testing when the electrical power supplying circuit is inside.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 18 – IEC 62343-2:2014 © IEC 2014

Table A.3 – Electromagnetic compatibility test items and their severities

Groups Tests Severity References


Electromagnetic Electromagnetic Class B FCC Part 15
interference interference
(non-operating) Class B CISPR 22
Class B EN 55022

Class B + α (original requirement) FCC Part 15

Class B + α (original requirement) CISPR 22

Class B + α (original requirement) EN 55022

Electromagnetic Class A (non-residential) electromagnetic GR-1312,


interference emissions immunity criteria in Clause 3
(non-operating) of GR-1089:2011 GR-1089

Electrostatic Electrostatic discharge Contact discharge: 8 kV IEC 61000-4-2,


discharge (non-operating) Air discharge: 15 kV Level 4
Contact discharge: 6 kV IEC 61000-4-2,
Air discharge: 8 kV Level 3
Electrostatic discharge TR-NWT-000870
(non-operating)
Electromagnetic Electromagnetic 80 MHz – 1 000 MHz, 10 V/m IEC 61000-4-3,
immunity immunity Level 3
(non-operating)
80 MHz -1 000 MHz, 3 V/m IEC 61000-4-3,
Level 2
Electromagnetic fast Electromagnetic fast IEC 61000-4-4,
transient/burst transient/burst Level 4
immunity test immunity test
(non-operating) IEC 61000-4-4,
Level 3
IEC 61000-4-4,
Level 2
IEC 61000-4-4,
Level 1
Surge Surge IEC 61000-4-5
(non-operating)
Immunity to Immunity to conducted IEC 61000-4-6
conducted disturbances
disturbances (non-operating)
Grounding Grounding GR-1089,
(non-operating) Chapter 9

A.5 Fibre integrity tests

Table A.4 shows test items and severity of fibre integrity tests. These kinds of tests are
common for pigtailed modules. It should be noted that some tests require monitoring during
the test. It is recommended to consider mounting methods and procedures when selecting
test items.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 19 –

Table A.4 – Fibre integrity test items and their severities

Groups Tests Severities References


Cable retention Cable retention 0,45 kgf for coated fibre, 5 s, 3 times GR-1209
(non-operating) 0,45 kgf for tight buffer, 5 s, 3 times
1 kgf for loose buffer, 5 s, 3 times
1 kgf for reinforced, 5 s, 3 times
Fibre cable retention 2 N for primary coated IEC 61753-1, cat C,
(operating) 5 N for secondary coated IEC 61300-2-4
10 N for reinforced
120 s duration for 10 N,
60 s duration for 2 N and 5 N
Fibre flex Fibre flex 0,45 kgf, 30 cycles for coated, tight buffer, GR-1209
(non-operating) loose buffer,
0,45 kgf, 300 cycles for reinforced
Fibre flexing 2 N for reinforced, ± 90 °, 30 cycles IEC 61753-1, cat C,
(operating) IEC 61300-2-44
Fibre twist Fibre twist 0,45 kgf 10 cycles for coated, tight buffer, GR-1209
(non-operating) loose buffer, reinforced.
Torsion/twist 5,0 N at 0,1 N/s for reinforced IEC 61753-1, cat O,
(non-operating) 2,0 N at 0,1 N/s for primary and secondary IEC 61300-2-5
coated 10 cycles ±180 °
Fibre side pull Fibre side pull 0,23 kgf 90 ° 5 s, 2 directions for coated, GR-1209
(non-operating) tight buffer, 0,45 kgf, 90 °, 5 s for loose
buffer, reinforced
Static side load 1 N for 1 h for reinforced cables, IEC 61753-1, cat C,
(operating) 0,2 N for 5 min for secondary coated fibres, IEC 61300-2-42
two mutually perpendicular directions
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 20 – IEC 62343-2:2014 © IEC 2014

Bibliography

IEC 60050-731, International Electrotechnical Vocabulary − Chapter 731: Optical fibre


communication

IEC 61000-4-2, Electromagnetic compatibility (EMC) − Part 4-2: Testing and measurement
techniques − Electrostatic discharge immunity test

IEC 61000-4-3, Electromagnetic compatibility (EMC) − Part 4-3: Testing and measurement
techniques − Radiated, radio-frequency, electromagnetic field immunity test

IEC 61000-4-4, Electromagnetic compatibility (EMC) − Part 4-4: Testing and measurement
techniques − Electrical fast transient/burst immunity test

IEC 61000-4-5, Electromagnetic compatibility (EMC) − Part 4-5: Testing and measurement
techniques − Surge immunity test

IEC 61000-4-6, Electromagnetic compatibility (EMC) − Part 4-6: Testing and measurement
techniques − Immunity to conducted disturbances, induced by radio-frequency fields

IEC 61291-5-2, Optical amplifiers – Part 5-2: Qualification specifications – Reliability


qualification for optical fibre amplifiers

IEC 61300-2-5, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-5: Tests – Torsion

IEC 61300-2-9, Fibre optic interconnecting devices and passive components – Basic test and
measurement procedures – Part 2-9: Tests – Shock

IEC 61300-2-42, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-42: Tests – Static side load for connectors

IEC 61300-2-44, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-44: Tests – Flexing of the strain relief of fibre optic
devices

IEC 61753-1, Fibre optic interconnecting devices and passive components performance
standard − Part 1: General and guidance for performance standards

IEC TR 61931, Fibre optic – Terminology

IEC 62343-6-5, Dynamic modules – Part 6-5: Design guide – Investigation of operating
mechanical shock and vibration tests for dynamic devices

CISPR 22, Information technology equipment − Radio disturbance characteristics − Limits and
methods of measurement

EN 55022, Information Technology Equipment – Radio disturbance characteristics – Limits


and methods of measurement

FCC Radio 47, Part 15, Communications equipment Computer technology

Telcordia GR-63, NEBS(TM) Requirements: Physical Protection


Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 21 –

Telcordia GR-1089:2011, Electromagnetic Compatibility and Electrical Safety − Generic


Criteria for Network Telecommunications Equipment

Telcordia GR-1209, Generic Requirements for Passive Optical Components

Telcordia GR-1221, Generic Reliability Assurance Requirements for Passive Optical


Components

Telcordia GR-1312, Generic Requirements for Optical Fiber Amplifiers and Proprietary Dense
Wavelength-Division Multiplexed Systems

Telcordia TR-NWT-000870, Electrostatic Discharge Control in the Manufacture of


Telecommunications Equipment

________________
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 22 – IEC 62343-2:2014 © IEC 2014

SOMMAIRE

AVANT-PROPOS .................................................................................................................. 24
1 Domaine d’application ................................................................................................... 26
2 Références normatives .................................................................................................. 26
3 Termes, définitions et abréviations ................................................................................ 27
3.1 Termes et définitions ............................................................................................ 27
3.2 Termes abrégés .................................................................................................... 27
4 Considérations sur la qualification de fiabilité ................................................................ 28
4.1 Généralités ........................................................................................................... 28
4.2 Approche générale ................................................................................................ 28
4.3 Conception du produit DM ..................................................................................... 28
5 Exigences de qualification de fiabilité ............................................................................ 29
5.1 Généralités ........................................................................................................... 29
5.2 Démonstration de la qualité du produit .................................................................. 29
5.3 Responsabilité des essais ..................................................................................... 30
5.4 Essais ................................................................................................................... 30
5.4.1 Caractéristiques complètes ............................................................................ 30
5.4.2 Qualification de fiabilité des composants, des constituants et des
interconnexions ............................................................................................. 30
5.4.3 Qualification de fiabilité du processus d'assemblage des modules
dynamiques ................................................................................................... 31
5.4.4 Qualification de fiabilité des modules dynamiques de Conception 1 ............... 31
5.4.5 Qualification de fiabilité des modules dynamiques de Conception 2 ............... 33
5.4.6 Critères d'acceptation/de rejet ....................................................................... 35
5.5 Procédure d'évaluation de la fiabilité ..................................................................... 35
5.5.1 Analyse des résultats de la fiabilité ................................................................ 35
5.5.2 Calculs de fiabilité ......................................................................................... 35
5.5.3 Méthodes d'essai de qualification de fiabilité ................................................. 36
6 Lignes directrices – AMDE et qualification-par-similitude ............................................... 36
Annexe A (informative) Eléments d'essai de fiabilité et leurs conditions .............................. 38
A.1 Généralités ........................................................................................................... 38
A.2 Essais environnementaux mécaniques .................................................................. 38
A.3 Essais environnementaux de température et d'humidité ........................................ 39
A.4 Essais de compatibilité électromagnétique ............................................................ 40
A.5 Essais d'intégrité des fibres .................................................................................. 41
Bibliographie ......................................................................................................................... 42

Tableau 1 – Liste minimale des essais exigés sur les modules dynamiques de
Conception 1 ........................................................................................................................ 32
Tableau 2 – Liste minimale des essais exigés sur les modules dynamiques de
Conception 2 ........................................................................................................................ 34
Tableau 3 – Taux de défaillance des constituants ................................................................. 36
Tableau 4 – Liste applicable de méthodes d'essai de fiabilité de l'IEC pour les
composants optiques ............................................................................................................ 36
Tableau A.1 – Essais environnementaux mécaniques et sévérité .......................................... 38
Tableau A.2 – Essais de température et d'humidité et sévérité ............................................. 39
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 23 –

Tableau A.3 – Eléments d'essai de compatibilité électromagnétique et leurs sévérités .......... 40


Tableau A.4 – Eléments d'essai de l'intégrité des fibres et leurs sévérités ............................ 41
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 24 – IEC 62343-2:2014 © IEC 2014

COMMISSION ÉLECTROTECHNIQUE INTERNATIONALE

____________

MODULES DYNAMIQUES –

Partie 2: Qualification de fiabilité

AVANT-PROPOS
1) La Commission Electrotechnique Internationale (IEC) est une organisation mondiale de normalisation
composée de l'ensemble des comités électrotechniques nationaux (Comités nationaux de l’IEC). L’IEC a pour
objet de favoriser la coopération internationale pour toutes les questions de normalisation dans les domaines
de l'électricité et de l'électronique. A cet effet, l’IEC – entre autres activités – publie des Normes internationales,
des Spécifications techniques, des Rapports techniques, des Spécifications accessibles au public (PAS) et des
Guides (ci-après dénommés "Publication(s) de l’IEC"). Leur élaboration est confiée à des comités d'études, aux
travaux desquels tout Comité national intéressé par le sujet traité peut participer. Les organisations
internationales, gouvernementales et non gouvernementales, en liaison avec l’IEC, participent également aux
travaux. L’IEC collabore étroitement avec l'Organisation Internationale de Normalisation (ISO), selon des
conditions fixées par accord entre les deux organisations.
2) Les décisions ou accords officiels de l’IEC concernant les questions techniques représentent, dans la mesure
du possible, un accord international sur les sujets étudiés, étant donné que les Comités nationaux de l’IEC
intéressés sont représentés dans chaque comité d’études.
3) Les Publications de l’IEC se présentent sous la forme de recommandations internationales et sont agréées
comme telles par les Comités nationaux de l’IEC. Tous les efforts raisonnables sont entrepris afin que l’IEC
s'assure de l'exactitude du contenu technique de ses publications; l’IEC ne peut pas être tenue responsable de
l'éventuelle mauvaise utilisation ou interprétation qui en est faite par un quelconque utilisateur final.
4) Dans le but d'encourager l'uniformité internationale, les Comités nationaux de l’IEC s'engagent, dans toute la
mesure possible, à appliquer de façon transparente les Publications de l’IEC dans leurs publications nationales
et régionales. Toutes divergences entre toutes Publications de l’IEC et toutes publications nationales ou
régionales correspondantes doivent être indiquées en termes clairs dans ces dernières.
5) L’IEC elle-même ne fournit aucune attestation de conformité. Des organismes de certification indépendants
fournissent des services d'évaluation de conformité et, dans certains secteurs, accèdent aux marques de
conformité de l’IEC. L’IEC n'est responsable d'aucun des services effectués par les organismes de certification
indépendants.
6) Tous les utilisateurs doivent s'assurer qu'ils sont en possession de la dernière édition de cette publication.
7) Aucune responsabilité ne doit être imputée à l’IEC, à ses administrateurs, employés, auxiliaires ou mandataires,
y compris ses experts particuliers et les membres de ses comités d'études et des Comités nationaux de l’IEC,
pour tout préjudice causé en cas de dommages corporels et matériels, ou de tout autre dommage de quelque
nature que ce soit, directe ou indirecte, ou pour supporter les coûts (y compris les frais de justice) et les
dépenses découlant de la publication ou de l'utilisation de cette Publication de l’IEC ou de toute autre
Publication de l’IEC, ou au crédit qui lui est accordé.
8) L'attention est attirée sur les références normatives citées dans cette publication. L'utilisation de publications
référencées est obligatoire pour une application correcte de la présente publication.
9) L’attention est attirée sur le fait que certains des éléments de la présente Publication de l’IEC peuvent faire
l’objet de droits de brevet. L’IEC ne saurait être tenue pour responsable de ne pas avoir identifié de tels droits
de brevets et de ne pas avoir signalé leur existence.

La Norme internationale IEC 62343-2 a été établie par le sous-comité 86C: Systèmes et
dispositifs actifs à fibres optiques, du comité d’études 86 de l'IEC: Fibres optiques.

Cette deuxième édition annule et remplace la première édition parue en 2011 et constitue une
révision technique. La principale modification par rapport à l’édition précédente consiste en
l'ajout de l'Annexe A (informative), Eléments d'essai de fiabilité et leurs conditions.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 25 –

Le texte de cette norme est issu des documents suivants:

CDV Rapport de vote


86C/1185/CDV 86C/1248/CDV

Le rapport de vote indiqué dans le tableau ci-dessus donne toute information sur le vote ayant
abouti à l'approbation de cette norme.

Cette publication a été rédigée selon les Directives ISO/IEC, Partie 2.

Une liste de toutes les parties de la série IEC 62343, publiées sous le titre général Modules
dynamiques, peut être consultée sur le site web de l'IEC.

Le comité a décidé que le contenu de cette publication ne sera pas modifié avant la date de
stabilité indiquée sur le site web de l’IEC sous "http://webstore.iec.ch" dans les données
relatives à la publication recherchée. A cette date, la publication sera

• reconduite,
• supprimée,
• remplacée par une édition révisée, ou
• amendée.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 26 – IEC 62343-2:2014 © IEC 2014

MODULES DYNAMIQUES –

Partie 2: Qualification de fiabilité

1 Domaine d’application

La présente partie de l'IEC 62343 s'applique aux dispositifs et aux modules dynamiques
disponibles sur le marché. Les exemples suivants peuvent être donnés: compensateurs de
dispersion chromatique accordables, commutateurs sélectifs en longueur d'onde et
contrôleurs de canal de transmission optique.

Les amplificateurs optiques ne sont pas inclus dans cette liste, mais ils sont traités dans
l'IEC 61291-5-2.

Dans le cadre de la qualification de fiabilité, certaines informations sur les composants, les
constituants et les interconnexions internes sont nécessaires; ces constituants internes sont
traités comme des boîtes noires. La présente norme donne les exigences pour l'évaluation de
la fiabilité des modules dynamiques en combinant la fiabilité de telles boîtes noires internes.

Les objectifs de la présente norme sont les suivants:

• spécifier les exigences pour la qualification de fiabilité des modules dynamiques;


• donner la liste minimale des essais de qualification de fiabilité, les exigences concernant
les critères de défaillance pendant un essai et les prévisions de fiabilité, et donner les
références normatives appropriées.

2 Références normatives

Les documents suivants sont cités en référence de manière normative, en intégralité ou en


partie, dans le présent document et sont indispensables pour son application. Pour les
références datées, seule l’édition citée s’applique. Pour les références non datées, la dernière
édition du document de référence s’applique (y compris les éventuels amendements).

IEC 61300-2-1, Dispositifs d'interconnexion et composants passifs à fibres optiques –


Méthodes fondamentales d'essais et de mesures – Partie 2-1: Essais – Vibrations
(sinusoïdales)

IEC 61300-2-4, Dispositifs d'interconnexion et composants passifs à fibres optiques –


Méthodes fondamentales d'essais et de mesures – Partie 2-4: Essais – Rétention de la fibre
ou du câble

IEC 61300-2-12, Dispositifs d'interconnexion et composants passifs à fibres optiques –


Méthodes fondamentales d'essais et de mesures – Partie 2-12: Essais – Impact

IEC 62005-9-1, Dispositifs d'interconnexion et composants passifs à fibres optiques –


Fiabilite – Partie 9-1: Qualification des composants optiques passifs 1

IEC 62005-9-2, Fiabilité des dispositifs d’interconnexion et des composants optiques passifs à
fibres optiques – Partie 9-2: Qualification relative à la fiabilité pour les ensembles de
connecteurs à une seule fibre optique – Unimodal

___________
1 A publier.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 27 –

IEC 62572 (toutes les parties), Composants et dispositifs actifs en fibres optiques – Normes
de fiabilité

ISO 9000: Systèmes de management de la qualité – Principes essentiels et vocabulaire

3 Termes, définitions et abréviations

3.1 Termes et définitions

Pour les besoins du présent document, les termes et définitions suivants s'appliquent.

3.1.1
défaillance
non-conformité à la spécification produit ou modification des paramètres établis par la norme
ou convenus avec le client et le fournisseur

3.1.2
qualification
terme généralement utilisé comme abréviation pour qualification de fiabilité

Note 1 à l'article: Elle est utilisée comme un essai formel pour déterminer si le produit convient ou non aux
applications de télécommunications et par conséquent, le résultat attendu est "acceptation ou rejet".

Note 2 à l'article: Elle est différente de l'essai de fiabilité, qui est par nature un «essai technique» de fiabilité. Les
essais de fiabilité sont conçus pour comprendre les considérations relatives à la fiabilité ou pour estimer la fiabilité
du produit. L’acceptation ou le rejet n'est pas le principal résultat.

3.1.3
fiabilité
< au sens temporel > période minimale de fonctionnement continu du module dynamique sans
aucune défaillance dans des conditions spécifiées de fonctionnement et d'environnement

3.1.4
fiabilité
< au sens fonctionnel > probabilité d’assurer des fonctions requises, dans des conditions
spécifiées de fonctionnement et d’environnement

Note 1 à l'article: La fiabilité d’un module dynamique est exprimée par l’un des deux paramètres suivants: soit le
temps moyen entre défaillances (MTBF) soit le nombre de défaillances dans un temps donné (FIT).
• le MTBF est la durée moyenne de fonctionnement continu du module dynamique sans aucune défaillance dans
des conditions spécifiées de fonctionnement et d'environnement.
• le FIT est le nombre de défaillances attendu pour 10 9 dispositif-heures dans des conditions de fonctionnement
et d'environnement spécifiées.

3.2 Termes abrégés

Terme Terme en français Equivalent en anglais


AMDE analyse des modes de défaillances et failure mode and effects analysis
de leurs effets (FMEA)
DM module dynamique dynamic module
DS sécification particulière detail specification
ESD décharge électrostatique electrostatic discharge
FIT nombre de défaillances dans un temps failure in time
donné
LCD affichage à cristaux liquides liquid crystal device
MTBF temps moyen entre défaillances mean time between failure
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 28 – IEC 62343-2:2014 © IEC 2014

Terme Terme en français Equivalent en anglais


HR humidité relative relative humidity (RH)
UCL niveau de confiance supérieur upper confidence level
VOA affaiblisseurs optiques variables variable optical attenuators

4 Considérations sur la qualification de fiabilité

4.1 Généralités

Puisque les modules dynamiques sont des produits relativement nouveaux sur le marché et
qu'ils font intervenir différentes technologies, les exigences incluses dans la présente norme
devront être révisées au fur et à mesure de l'évolution de la technologie.

4.2 Approche générale

Cela vaut la peine d'insister sur l'approche fondamentale de la qualification de fiabilité


adoptée dans la présente norme:

a) Tous les constituants qui peuvent être qualifiés efficacement sur leurs niveaux individuels
doivent être qualifiés à ce niveau. Leur qualification doit être basée sur les normes IEC,
ou sur d'autres normes industrielles en l'absence de normes IEC.
b) Les essais de qualification exigés au niveau des modules dynamiques doivent être basés
sur les mécanismes de dégradation et les modes de défaillance qui ne peuvent pas être
détectés efficacement à des niveaux de constituants inférieurs. Au niveau du module
dynamique, les essais de qualification ne doivent pas tendre à découvrir ni à identifier les
mécanismes de dégradation et les modes de défaillance qui peuvent être découverts aux
niveaux d'assemblage inférieurs à celui du produit final. Par exemple, si tous les
constituants d'un module dynamique peuvent être efficacement soumis à un essai de
chaleur humide accéléré provoquant des dégradations, il n'y a pas lieu de répéter l'essai
de chaleur humide au niveau du module dynamique.

4.3 Conception du produit DM

Un module dynamique est un ensemble de différents composants, constituants et


interconnexions. Il existe deux conceptions de base sur le marché actuel des modules
dynamiques:

a) Conception 1: les constituants (terme général qui inclut les composants, les constituants
et les interconnexions utilisés pour constituer un module dynamique du point de vue de la
présente norme) sont emballés séparément. Leurs emballages sont généralement
hermétiques ou résistants à l'humidité. Ils sont intégrés dans un boîtier (généralement
non-hermétique ou ne résistant pas à l'humidité).
b) Conception 2: certains constituants utilisés dans des modules dynamiques sont des
éléments optiques de base non encapsulés (par exemple, cristaux, lentilles, miroirs, etc.).
Ces constituants ne peuvent pas être qualifiés efficacement de manière individuelle. Ces
constituants ou éléments sont intégrés et encapsulés à l'intérieur d'un boîtier hermétique
ou d’un boîtier résistant à l’humidité.

Dans la Conception 1, les constituants individuels peuvent être soumis à un essai et qualifiés
individuellement et par conséquent, la qualification des modules dynamiques n’a pas à
répéter les essais qui sont effectués au niveau des constituants pour les mêmes mécanismes
de dégradation et modes de défaillance.

Dans la Conception 2, la qualification des modules dynamiques se concentre à nouveau sur


les essais qui ne peuvent pas être effectués efficacement aux niveaux inférieurs
d'assemblages (c’est-à-dire, au niveau du constituant de base). Toutefois, dans ce cas, un
plus grand nombre d'essais est généralement nécessaire puisque les constituants ne peuvent
pas être soumis efficacement à un essai individuel à leur niveau.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 29 –

En raison des différences de conception, et par conséquent des différents mécanismes et


modes de défaillance, différentes méthodes d'essai de qualification doivent être développées
séparément. Elles sont décrites en 5.4.4 pour la Conception 1 et en 5.4.5 pour la Conception
2, respectivement.

5 Exigences de qualification de fiabilité

5.1 Généralités

Pour les besoins de la présente norme, toutes les interconnexions, tous les constituants et
tous les composants internes doivent être traités comme une boîte noire. Il est également
important de préciser que les constituants dans le module dynamique de cette conception
incluent les épissures des fibres, le cheminement des fibres et la fixation des fibres, ainsi que
la façon dont la fibre sort de l'enveloppe et la façon dont les constituants sont montés.

La présente norme est basée sur l'hypothèse selon laquelle la fiabilité d'un module
dynamique peut être évaluée avec une confiance suffisante à partir des taux de nombre de
défaillances de ses boîtes noires internes quand le processus d’assemblage des éléments
constituants a été qualifié.

Certaines dégradations et défaillances ne sont pas dues aux défaillances des constituants.
Un exemple est le cheminement des fibres et les supports des fibres. La qualité et la fiabilité
de l’assemblage, par exemple le cheminement des fibres, doivent être évaluées et qualifiées
par l'évaluation et la qualification du processus. Les procédures pour qualifier le processus
d'assemblage sont décrites en 5.4.3.

Une liste des boîtes noires internes constituant souvent un module dynamique est donnée ci-
dessous:

• des composants optiques passifs, y compris les cordons de brassage, les fibres amorces,
les connecteurs et les épissures;
• des composants optiques actifs;
• des ensembles électroniques, y compris les cartes de circuit imprimé, les connecteurs
électriques, etc.;
• d'autres éléments (par exemple, les épissures de fibres, le cheminement des fibres et la
fixation des fibres, ainsi que la façon dont la fibre sort de l'enveloppe et dont les
composants sont montés).

Les fabricants de modules dynamiques doivent déclarer le nombre et le type de boîtes noires
internes constituant le module dynamique et donner les taux de défaillance (en nombre de
défaillances dans le temps) pour chaque boîte noire.

Le taux de défaillance d’un module dynamique doit être calculé en combinant


convenablement les taux de défaillance en nombre de défaillances dans le temps de ses
boîtes noires, comme cela est décrit en 5.5.2. Le modèle et les hypothèses utilisés pour le
calcul des taux de défaillance d’un module dynamique doivent être donnés et justifiés pour
être examinés, si le fabricant du module dynamique le demande.

5.2 Démonstration de la qualité du produit

Puisque les essais de qualification de fiabilité sont effectués sur un nombre limité d'unités, il
est essentiel d'avoir un système de gestion de la qualité en place pour garantir que la qualité
de toutes les unités est cohérente. Un essai sur un nombre limité d'échantillons sera
représentatif des unités de production à livrer une fois la qualification terminée.

La présente norme (si cela est exigé par la spécification particulière) spécifie les exigences
obligatoires minimales pour évaluer la qualification de fiabilité d'un module dynamique et elle
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 30 – IEC 62343-2:2014 © IEC 2014

est destinée à faire partie d'un programme de fiabilité des modules dynamiques et d'un
système de gestion de la qualité globaux développés et mis en œuvre par le fabricant de
modules dynamiques.

Le fabricant de modules dynamiques doit montrer:

• un processus de fabrication documenté et audité, comprenant la qualification de fiabilité


des constituants achetés, en conformité avec l’ISO 9000;
• des données de performances des unités de production, celles-ci doivent pouvoir être
passées en revue, et la distribution de ces données doit montrer que les processus sont
soumis à des contrôles appropriés;
• un programme de qualification de fiabilité, y compris, par exemple, des essais de durée de
vie accélérés, un rodage et un déverminage des constituants et des modules dynamiques;
• un programme de maintenance de la qualification de fiabilité pour assurer la continuité de
la qualification (ce programme peut prendre la forme d'essais périodiques de qualification
de fiabilité du produit ou de produits semblables);
• une procédure pour assurer un retour approprié vers le développement et la production
des problèmes de fiabilité.

5.3 Responsabilité des essais

Le fabricant de modules dynamiques est responsable de la réalisation des essais de


qualification de fiabilité.

Les essais détaillés dans la présente norme doivent être effectués par le fabricant de
modules dynamiques. Des essais supplémentaires peuvent être spécifiés dans les
spécifications particulières.

5.4 Essais

5.4.1 Caractéristiques complètes

Une caractérisation complète du produit portant sur ses performances (pouvant être au-delà
de celles stipulées dans les spécifications de performance) et couvrant toutes les conditions
de fonctionnement (pouvant aller au-delà de celles stipulées dans les spécifications des
conditions de fonctionnement) doit être effectuée. Les données doivent être collectées et
analysées (minimales pour la moyenne et l'écart type), et être disponibles pour être
examinées.

5.4.2 Qualification de fiabilité des composants, des constituants et des


interconnexions

Tous les composants, tous les constituants et toutes les interconnexions utilisés pour
construire des modules dynamiques doivent être qualifiés conformément aux normes IEC
appropriées. Les composants peuvent inclure, sans s'y limiter, des affaiblisseurs optiques
variables, des prises ou des séparateurs, des détecteurs, des isolateurs, des circulateurs, des
composants électroniques, des connexions épissurées (y compris l’encapsulation ou le
revêtement), des cristaux, des miroirs, des prismes, etc.

Si les normes IEC pour ces constituants sont en cours de développement ou si elles ne sont
pas encore disponibles, il convient d’adopter les normes IEC applicables aux constituants
ayant des modes de défaillance et des mécanismes de dégradation similaires. Une analyse
de similitude des modes de défaillance et des mécanismes de dégradation doit être fournie
pour étayer cette approche.

Les conceptions qui utilisent de nombreux constituants identiques doivent ère examinées. Les
taux de défaillance de tels constituants peuvent contribuer de manière significative au taux de
défaillance ou au temps d'arrêt global du système. Il convient également d’étudier la
dégradation cumulative des constituants individuels. Les résultats peuvent nécessiter des
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 31 –

essais sur des échantillons supplémentaires ou des définitions de défaillance plus


rigoureuses.

En outre, les critères d’acceptation et de rejet de la qualification d’un constituant doivent être
examinés minutieusement pour déterminer si la qualification du constituant est appropriée.
Par exemple, si plusieurs prises 1x2 sont utilisées dans une conception de série, non
seulement le taux de défaillance est multiplié mais également la dégradation (c’est-à-dire que
le critère d’acceptation ou de rejet à 0,5 dB est multiplié), ce qui peut ne pas être acceptable.
Le critère d’acceptation et de rejet des constituants qui est généralement défini avec une
valeur de 0,5 dB de variation des pertes d'insertion n’est pas assez strict pour les besoins
d’un produit tel qu'un module dynamique. L'évaluation de critères plus stricts doit être
effectuée et l'état de qualification doit être justifié.

5.4.3 Qualification de fiabilité du processus d'assemblage des modules dynamiques

Le cheminement des fibres et le montage des composants sont tous les deux des processus
importants de l’assemblage d’un module qui peuvent contribuer largement au taux de
défaillance s'ils ne sont pas réalisés correctement. Leurs conceptions et leurs processus
doivent être soigneusement documentés et soumis à des essais. Toute modification doit être
accompagnée de données expérimentales appropriées.

Si le cheminement des fibres est documenté et contrôlé de manière approfondie (par exemple,
par des mesures de performance avant et après le cheminement) et que le module
dynamique final est qualifié, le processus de cheminement des fibres peut être considéré
comme un processus qualifié et il peut être utilisé dans d'autres produits semblables pour
réaliser un produit réputé comme qualifié par similitude.

5.4.4 Qualification de fiabilité des modules dynamiques de Conception 1

Comme cela est décrit en 5.1 pour la Conception 1, les constituants (composants utilisés pour
réaliser un module dynamique) sont emballés séparément. Leurs emballages sont
généralement hermétiques ou résistants à l'humidité. Ils sont intégrés dans un boîtier
(généralement non-hermétique ou ne résistant pas à l'humidité).

Une procédure de qualification de fiabilité concernant les modules dynamiques complets est
décrite dans le Tableau 1. Elle donne la liste minimale des essais à réaliser sur les modules
dynamiques pour assurer la fiabilité.

Pour les essais, aucune défaillance n'est admise. Les essais peuvent être réalisés de
manière séquentielle ou en parallèle. Pour les essais “en fonctionnement”, il convient de
surveiller les paramètres appropriés pendant l’essai.

Sur la base de l’assurance de la fiabilité exigée pour les essais de fiabilité pour les boîtes
noires internes des modules dynamiques, le niveau d'échantillonnage est généralement bas
(par exemple quelques échantillons pour chaque type de module dynamique).

Dans certains cas spécifiques l'utilisation d’adhésifs dans le module dynamique peut être
considérée comme un processus critique et doit nécessiter une qualification distincte. Selon
la fonction possible de l'adhésif (ancrage mécanique, protection d'épissure, adaptation
d’indice, etc.), les différents modes de défaillance doivent être traités et accompagnés de
données de fiabilité ou de qualification.

Le point principal dans la qualification de fiabilité d’un module dynamique de Conception 1 est
de garantir que la fiabilité de chaque constituant n'est pas dégradée dans le processus de
fabrication utilisé.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 32 – IEC 62343-2:2014 © IEC 2014

Tableau 1 – Liste minimale des essais exigés sur les modules


dynamiques de Conception 1

Essai Condition Durée Echantillons


Vieillissement actif à haute température 85 °C 2 000 h 3

Cycles de température en T op, min /T op, max


100 cycles 3
fonctionnement >1 °C/min
Chute d'une hauteur de
a 100 mm si <10 kg, chute Voir le tableau ci-
Chute(impact) 3
de 75 mm si dessous
10 kg − 25 kg
Essai mécanique hors
fonctionnement b 10 Hz à 55 Hz, 1,52 mm,
Vibration 2 h par direction 3
1 octave/min

c Voir le tableau ci-


Traction 5/10/100 N 3
dessous
400 m/s 2 , 5ms pour
+/- axe-z,

d 200 m/s 2 , 5ms pour


Choc en fonctionnement 3 fois/direction 3
+/- axe-x,
100 m/s 2 , 5 ms for
+/- axe-y
50 Hz à 500 Hz,
20 m/s 2 pour axe-z, 2
d
Vibration en fonctionnement 3
10 m/s 2 pour axe-x, balayages/direction

5 m/s 2 pour axe-y

NOTE Une référence à la méthode d’essai de cycle de température est fournie à l'Article A.3.
a Essai mécanique Impact (chute) (IEC 61300-2-12 pour les chutes)
Masse Hauteur de chute
kg mm
0 à < 10 100

10 à < 25 75
b Essai mécanique: vibrations (sinusoïdales, IEC 61300-2-1).
c Essai de fibre amorce (essai de traction). La première valeur dans chaque rangée est le diamètre extérieur
de la fibre sous revêtement protecteur ou câblée à laquelle les conditions d’essai spécifiées s’appliquent.
2 mm: 20 N à 100 N, 3 fois, tractions de 5 s
Rétention
du câble 900 µm 10 N, 3 fois, tractions de 5 s IEC 61300-2-4
(traction)
250 µm: 5 N, 3 fois, tractions de 5 s
d Les directions des axes x, y et z sont définies par la direction de montage sur une carte dans un
équipement (axe-x: direction d'après l'avant et l'arrière de la carte à monter lorsqu'elle est installée dans un
bloc d'équipement, axe-y: direction d'après la gravité (haut et bas) de la carte à monter lorsqu'elle est
installée dans un bloc d'équipement, axe-z: direction qui est perpendiculaire à la carte à monter.) Si un
contrôleur ne peut pas définir la direction de montage, l'essai doit être réalisé dans les conditions les plus
sévères pour toutes les directions.

Il est essentiel que les modules dynamiques évalués soient entièrement représentatifs de la
production normale et qu’ils aient passé avec succès toutes les procédures de production
et/ou les procédures de rodage et de déverminage spécifiées (s’il y a lieu dans le module
dynamique).

Les aspects des conditions d'essai qui ne sont pas traités dans la présente norme sont
donnés dans les spécifications particulières applicables.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 33 –

5.4.5 Qualification de fiabilité des modules dynamiques de Conception 2

Une procédure de qualification de fiabilité concernant les modules dynamiques de conception


2 est décrite dans le Tableau 2. Dans le cas d’un module dynamique de Conception 2, on ne
peut pas soumettre efficacement tous les constituants individuellement à un essai (voir 4.3).
Par conséquent, de nombreux essais d’environnement à long terme ne peuvent être menés et
qualifiés efficacement qu'au niveau de l’assemblage du produit final d’un module dynamique.

Pour les essais, aucune défaillance n'est admise. Les essais peuvent être réalisés de
manière séquentielle ou en parallèle. Pour les essais “en fonctionnement”, il convient de
surveiller les paramètres appropriés pendant l’essai.

Par exemple, certains des constituants peuvent avoir été qualifiés suite à l'essai de chaleur
humide, mais d'autres peuvent ne pas satisfaire à l'essai de chaleur humide, comme exigé
pour les applications de télécommunications. Par conséquent, les unités de modules
dynamiques avec tous les constituants assemblés doivent être soumises à un essai dans des
conditions de chaleur humide. Même s’ils peuvent paraître redondants, ces essais sont
nécessaires.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 34 – IEC 62343-2:2014 © IEC 2014

Tableau 2 – Liste minimale des essais exigés sur les modules


dynamiques de Conception 2

Essai Condition Durée Echantillons


Vieillissement actif à haute température 85 °C 2 000 h 3
T op, min /T op, max
Cycles de température en fonctionnement 100 cycles 3
>1 °C/min
Chaleur humide 85 °C/85 % HR a 500 h 3
Chute d'une hauteur de
b 100 mm si <10 kg, et Voir le tableau ci-
Chute (impact) 3
chute de 75 mm si dessous
10 kg – 25 kg
Essai mécanique
hors fonctionnement c 10 Hz à 55 Hz, 1,52mm,
Vibrations 2 h par direction 3
1 octave/min

d Voir le tableau ci-


Traction 5/10/100 N 3
dessous
400 m/s 2 , 5ms pour
± axe-z,

e 200 m/s 2 , 5ms pour


Choc en fonctionnement 3 fois/direction 3
± axe-x,
100 m/s 2 , 5ms
pour ± axe-y
50 Hz à 500 Hz,
20 m/s 2 pour axe-z
e
Vibrations en fonctionnement 2 balayages/direction 3
10 m/s 2 pour axe-x
5 m/s 2 pour axe-y

Herméticité (contrôlée avant et après 3


∆T = 100 °C 15 cycles
le choc thermique liquide-liquide) boîte inerte
NOTE Une référence à la méthode d’essai de cycle de température est donnée à l'Article A.3.
A Chaleur humide: l'essai de chaleur humide à 85 °C/85 % HR pendant 100 h a été préconisé par certains
fabricants. Ces conditions d’essai peuvent être utilisées. Sinon, l’essai de chaleur humide à 40 °C/93 % HR
pendant une durée bien plus longue peut être utilisé, la durée réelle devant être déterminée par le facteur
d’accélération.
b Essai mécanique: impact (IEC 61300-2-12).
Masse Hauteur de chute
kg mm
0 à < 10 100

10 à < 25 75
c Essai mécanique: vibrations (sinusoïdales, IEC 61300-2-1).
d Essai de fibre amorce (essai de traction). La première valeur dans chaque rangée est le diamètre extérieur
de la fibre sous revêtement protecteur ou câblée à laquelle les conditions d’essai spécifiées s’appliquent.
2 mm: 20 N à 100 N, 3 fois, tractions de 5 s
Rétention
du câble 900 µm: 10 N, 3 fois, tractions de 5 s IEC 61300-2-4
(traction)
250 µm: 5 N, 3 fois, tractions de 5 s
e Les directions des axes x, y et z sont définies par la direction de montage sur une carte dans un bloc
d'équipement (axe-x: direction d'après l'avant et l'arrière de la carte à monter lorsqu'elle est installée dans
un bloc d'équipement, axe-y: direction d'après la gravité (haut et bas) de la carte à monter lorsqu'elle est
installée dans un bloc d'équipement, axe-z: direction qui est perpendiculaire à la carte à monter.) Si un
contrôleur ne peut pas définir la direction de montage, l'essai doit être réalisé dans les conditions les plus
sévères pour toutes les directions.

Il est essentiel que les modules dynamiques évalués soient entièrement représentatifs de la
production normale et qu’ils aient subi toutes les procédures de production et/ou les
procédures de rodage et de déverminage spécifiées (s’il y a lieu dans le module dynamique).
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 35 –

Les aspects des conditions d'essai non fournis dans la présente norme sont donnés dans les
normes applicables.

5.4.6 Critères d'acceptation/de rejet

Il convient de noter que le critère de défaillance communément utilisé pour une dérive de
perte d’insertion supérieure à 0,5 dB est une ligne directrice. Pour les modules dynamiques
DWDM, tels que les bloqueurs de longueur d’onde, la dérive de longueur d’onde centrale doit
être définie comme un critère de défaillance. Il convient de développer les critères réels et
pratiques en se basant sur la dégradation admise pour la durée de vie prévue pour le produit.
Un exemple est fourni ci-dessous pour illustrer la détermination.

EXEMPLE:

• Le facteur d'accélération de la condition d'essai par rapport à la condition de fonctionnement est de 50.
• La mesure paramétrique du début de vie est 1,0 dB en dessous de la spécification de fin de vie.
• La durée de vie prévue est prise comme étant de 20 ans.
• La dégradation admise pour un essai de 2 000 h est: (1,0*50*2 000)/(20*365,25*24) = 0,57 dB.
• A noter que la perte d’insertion n’est pas le seul paramètre pris en compte concernant l’acceptation ou le rejet ;
d’autres paramètres le sont aussi.

5.5 Procédure d'évaluation de la fiabilité

5.5.1 Analyse des résultats de la fiabilité

Les clients/fournisseurs de modules dynamiques doivent disposer d'une procédure pour


analyser et vérifier les indications de fiabilité d’un fabricant de modules dynamiques. En
particulier, il convient que la procédure inclue l'analyse

• des données relatives à l’essai d’endurance pour le module dynamique complet,


• des données d'essai pour les constituants internes,
• des résultats des essais environnementaux.

L'analyse des résultats conduit à consigner les paramètres de fiabilité du module dynamique
pour chaque type de dispositif ou de sous-système. Les paramètres de fiabilité
minimauxdoivent être présentés comme dans le Tableau 4 (voir ci-dessous).

5.5.2 Calculs de fiabilité

Une prévision de fiabilité portant sur le module dynamique complet est fournie par le fabricant
du module dynamique, sur la base des taux de défaillance (en nombre de défaillances dans le
temps, FIT) des boîtes noires internes composant le module dynamique (Conception 1) ou sur
la base des données pour le module dynamique complet (Conception 2).

Les taux de défaillance des boîtes noires internes doivent être donnés par le fabricant de
modules dynamiques en tenant compte des valeurs de base issues des heures cumulées des
composants provenant des différents constituants inclus dans le module dynamique. Les
calculs pour chaque boîte noire interne doivent être basés sur les normes actuelles traitant
des calculs de fiabilité.

Les calculs de fiabilité incluront également les défauts d'usure. Les nombres de défaillances
dans le temps (FIT) donnés pour chaque boîte noire interne doivent tenir compte de tous les
modes de défaillance prévus.

Les nombres de défaillances dans le temps des boîtes noires internes doivent être combinés
pour donner le taux de défaillance du module dynamique de Conception 1 comme cela est
expliqué dans le Tableau 3.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 36 – IEC 62343-2:2014 © IEC 2014

Tableau 3 – Taux de défaillance des constituants

Nombre
Elément Valeur mesurée (UCL 95 %)
d'éléments

Epissure n2 A2 FIT (défaillance aléatoire)


Connecteur n3 A3 FIT (défaillance aléatoire)

Electronique n4 A4 FIT (défaillance aléatoire)

Composant actif de type 1 n (4+1) A (4+1) FIT (défaillance aléatoire et d'usure)

Composant actif de type 2 n (4+2) A (4+2) FIT (défaillance aléatoire et d'usure)

………………………………………… …………………………………………………
Composant actif de type m n (4+m) A (4+m) FIT (défaillance aléatoire et d'usure)

Autre composant interne de type 1 n (4+m+1) A (4+m+1) FIT (défaillance aléatoire)

Autre composant interne de type 2 n (4+m+2) A (4+m+2) FIT (défaillance aléatoire)


………………………………………… ……………………………….
Autre composant interne de type h n (4+m+h) A (4+m+h) FIT (défaillance aléatoire)

Composant optique passif de type 1 n (4+m+h+1) A (4+m+h+1) FIT (défaillance aléatoire)

Composant optique passif de type 2 n (4+m+h+2) A (4+m+h+2) FIT (défaillance aléatoire)

………………………………………… ……………………………….
Composant optique passif de type k n (4+m+h+k) A (4+m+h+k) FIT (défaillance d'usure)
Cheminement des fibres
Fixation de composant optique n (4+m+h+k) A (4+m+h+k) FIT
Tout autre mode de défaillance identifié
n (4+m+h+k) A (4+m+h+k) FIT
dans l'AMDEC
Taux de défaillance total ∑ i A i *n I
NOTE n i est le nombre de composants de chaque type inclus dans le module dynamique.

5.5.3 Méthodes d'essai de qualification de fiabilité

Le Tableau 4 donne une liste de références normatives indiquant les essais de qualification
de fiabilité et les conditions d'essai appropriés pour les composants utilisés pour les modules
dynamiques.

Tableau 4 – Liste applicable de méthodes d'essai de fiabilité de l'IEC


pour les composants optiques

Composants Référence IEC


(référence du document de qualification de fiabilité)
Composants optiques passifs IEC 62005-9-1
Connecteurs optiques IEC TR 62005-9-2
Composants optiques actifs Série IEC 62572

6 Lignes directrices – AMDE et qualification-par-similitude

Cela vaut la peine de souligner que les essais de qualification ou d'évaluation de la fiabilité
doivent être basés sur les mécanismes de dégradation et les modes de défaillance. Les
essais accélérés appropriés peuvent être développés une fois que les mécanismes de
dégradation, les modes de défaillance et leurs facteurs d'accélération sont compris. Il
convient de commencer par développer l'analyse des modes de défaillance et leurs effets
(AMDE). Il convient que l'AMDE donne lieu à une planification et à la réalisation d'un
ensemble d'essais de fiabilité. Les résultats des essais peuvent être utilisés pour développer
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 37 –

des essais supplémentaires ou des essais affinés pour mieux comprendre les mécanismes de
dégradation ou développer les modèles d'accélération.

Lorsqu'une gamme de modules dynamiques est produite par un fabricant de modules


dynamiques, différents codes de type peuvent présenter d'importantes similitudes. Il est donc
permis de combiner les résultats de différents programmes d'essai, le cas échéant.

Il convient de prendre en compte le fait que de légères différences de technologie ou de


traitement peuvent parfois avoir un impact important sur la fiabilité, bien qu'elles ne soient
pas évidentes pendant l'évaluation de la qualité.

Au minimum, l'AMDE doit être réalisée pour toutes les variétés de produits considérés comme
"semblables" et qui seront réputés "qualifiés par similitude". L'AMDE doit être réalisée
minutieusement pour constituer un outil efficace de prise en compte des produits "qualifiés
par similitude". Sa précision peut être vérifiée par l'analyse des modes de défaillances (FMA)
issue des pertes de fabrication et des retours clients.

Il convient de présenter des preuves qui démontrent que tous les résultats sont pertinents.
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 38 – IEC 62343-2:2014 © IEC 2014

Annexe A
(informative)

Eléments d'essai de fiabilité et leurs conditions

A.1 Généralités

La présente annexe donne des informations concernant les éléments d'essai de fiabilité et les
conditions pour les modules dynamiques. Le contrôleur peut choisir les éléments d'essai de
fiabilité et les conditions en se référant à ce qui suit.

A.2 Essais environnementaux mécaniques

Le Tableau A.1 donne la sévérité des éléments d'essai pour les essais environnementaux
mécaniques. Pour un module dynamique avec des constituants mobiles, comme les miroirs
MEMS, il est fortement recommandé de réaliser des essais de chocs et de vibrations
mécaniques en fonctionnement. Les essais de chocs et de vibrations sont réalisés en
contrôlant les performances des modules dynamiques au cours des essais. Il est
recommandé de réaliser les essais de vibrations au cours du transport et de chute lors des
manipulations sur les modules emballés.

Tableau A.1 – Essais environnementaux mécaniques et sévérité

Groupes Eléments d'essai Sévérité Références


Chocs Chocs mécaniques (en 400 m/s 2 , 5 ms pour ± axe-z IEC 62343-6-5
mécaniques fonctionnement) 200 m/s 2 , 5 ms pour ± axe-x
100 m/s 2 , 5 ms pour ± axe-y
3 fois pour chaque direction
Vibrations Vibrations mécaniques 50 Hz – 500 Hz IEC 62343-6-5
(en fonctionnement) 20 m/s 2 pour l'axe-z
10 m/s 2 pour l'axe x
5 m/s 2 pour l'axe y
1 octave/min
2 balayages pour chaque direction
Chocs/impacts Chocs mécaniques 5 000 m/s 2 , 3 axes, 2 impacts/direction GR-1209,
mécaniques (composants) (12 impacts au total) IEC 61753-1,
(hors fonctionnement) Impulsion semi sinusoïdale nominale 1 ms, IEC 61300-2-9
(poids: ≤ 0,125 kg)
Chocs mécaniques 2 000 m/s 2 , 3 axes, 2 impacts/direction GR-1209,
(module) (12 impacts au total) IEC 61753-1,
(hors fonctionnement) Impulsion semi sinusoïdale nominale 1,33 ms, IEC 61300-2-9
(poids: > 0,125 et ≤ 0,225 kg)
500 m/s 2 , 3 axes, 2 impacts/direction GR-1209,
(12 impacts au total) IEC 61753-1,
Impulsion semi sinusoïdale nominale 5 ms, IEC 61300-2-9
(poids: >0,225 et ≤1 kg)
Chute non-emballé 100 mm de hauteur pour un poids ≤10 kg GR-63
(hors fonctionnement) 75 mm de hauteur pour un poids >10 kg et
≤25 kg
Vibrations Vibrations 10 Hz – 55 Hz, amplitude 1,52 mm , 3 axes GR-1209
mécaniques (hors fonctionnement) (20 min/axis) pour 1 h
Vibrations 10 Hz – 5 Hz, amplitude 0,75 mm, 3 axes, 1 IEC 61753-1
(hors fonctionnement) octave/min, 15 balayages par direction IEC 61300-2-1
Vibrations/impact Vibrations pendant le 5 Hz – 20 Hz, 0,01 g 2 /Hz, 20 – 200 Hz, GR-63
pendant le transport – emballés –3 dB/octave
Transport (hors fonctionnement)
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 39 –

Groupes Eléments d'essai Sévérité Références


Chute pendant les 1 m de hauteur pour un poids ≤10 kg GR-63
manipulations
(hors fonctionnement)

A.3 Essais environnementaux de température et d'humidité

Le Tableau A.2 donne la sévérité des éléments d'essai pour les essais environnementaux de
température et d'humidité. Ces types d'essais sont les plus courants pour la vérification de la
conception et la fiabilité. Pour les modules scellés de manière hermétique, il est possible de
ne pas réaliser les essais de chaleur humide et d'humidité élevée. Pour les modules semi-
scellés (scellés à la résine), il convient de noter que les modules d'essai peuvent absorber
l'humidité. Pour les modules encapsulés scellés hermétiquement, il est recommandé de
réaliser un essai d'analyse de gaz résiduel (RGA).

Tableau A.2 – Essais de température et d'humidité et sévérité

Groupes Eléments d'essai Sévérité Références


Haute température Haute température 60 °C ±2 °C, 96 h IEC 61753-1 cat C,
(hors IEC 61300-2-18
fonctionnement)
Basse température Basse température –10 °C ±2 °C, 96 h IEC 61753-1 cat C,
(hors IEC 61300-2-17
fonctionnement)
Cycles de Cycles de –40 °C à 70 °C, 10 cycles, durée des GR-1209
température température paliers: 12 min, vitesse de variation:
(hors 1 °K /min
fonctionnement)
Cycles de Variation de –10 °C ±2 °C à 60 °C ±2 °C, durée: 60 IEC 61753-1 cat C,
température température min, taux de variation 1 °K/min, 5 cycles IEC 61300-2-22
(en fonctionnement)
Effet de température –10 °C à 60 °C, durée des paliers: 30 min GR-1209
DWDM
(en fonctionnement)
Choc de Choc thermique 30 °K/h à –40 °C, –40 °C pendant 72 h, GR-63
température basse température 5 min jusqu'à la RT
(hors
fonctionnement)
Choc thermique 30 °K/h à 70 °C, 70 °C pendant 72 h, GR-63
haute température 5 min jusqu'à la RT
(hors
fonctionnement)
Chaleur humide Vieillissement par 75 °C, 90 % HR, 168 h GR-1209
l'humidité et la
température
(hors
fonctionnement)
Chaleur humide 40 °C ±2 °C, 93 % +2 %, 96 h IEC 61753-1 cat C,
continue −3
(hors IEC 61300-2-19
fonctionnement)
Humidité relative 40 °C, 93 %, 96 h GR-63
élevée
(hors
fonctionnement)
Chaleur humide 30 °C, 80 %, 96 h JIS C 5901
continue
(hors
fonctionnement)
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 40 – IEC 62343-2:2014 © IEC 2014

Groupes Eléments d'essai Sévérité Références


Cycles d'humidité Cycles de –10 °C à 60 °C, humidité de 20 % GR-1209
et de température température et à 85 % HR
d'humidité
(en fonctionnement)

A.4 Essais de compatibilité électromagnétique

Le Tableau A.3 donne les éléments d'essai et la sévérité des essais de compatibilité
électromagnétique. Pour les modules dynamiques qui utilisent un LCD (liquid crystal device)
comme dispositif de pilotage, une tension alternative peut être nécessaire comme tension de
commande électrique. Un circuit convertisseur DC/AC peut avoir un impact sur les décharges
électrostatiques, etc. Pour un module dynamique qui utilise un moteur MEMS électrostatique
à l'intérieur, il est admis de monter un circuit de conversion à tension plus élevée. Il est
recommandé de réaliser les essais ESD lorsque le circuit d'alimentation électrique est à
l'intérieur.

Tableau A.3 – Eléments d'essai de compatibilité électromagnétique et leurs sévérités

Groupes Essais Sévérité Références


Brouillage Brouillage Classe B FCC Partie 15
électromagnétique électromagnétique
(hors fonctionnement) Classe B CISPR 22
Classe B EN 55022

Classe B + α (exigences d’origine) FCC Partie 15

Classe B + α (exigence originale) CISPR 22

Classe B + α (exigence originale) EN 55022

Brouillage Classe A (non-résidentiel) critères GR-1312,


électromagnétique d'immunité aux émissions
(hors fonctionnement) électromagnétiques dans l'Article 3 du GR- GR-1089
1089:2011
Décharge Décharge Décharge par contact: 8 kV IEC 61000-4-2,
électrostatique électrostatique Décharge dans l'air: 15 kV Niveau 4
(hors fonctionnement)
Décharge par contact: 6 kV IEC 61000-4-2,
Décharge dans l'air: 8 kV Niveau 3
Décharge TR-NWT-000870
électrostatique
(hors fonctionnement)
Immunité Immunité 80 MHz – 1 000 MHz, 10 V/m IEC 61000-4-3,
électromagnétique électromagnétique Niveau 3
(hors fonctionnement)
80 MHz – 1 000 MHz, 3 V/m IEC 61000-4-3,
Niveau 2
Essai d'immunité Essai d'immunité IEC 61000-4-4,
électromagnétique électromagnétique aux Niveau 4
aux transitoires transitoires rapides en
rapides en salves salves IEC 61000-4-4,
(hors fonctionnement) Niveau 3
IEC 61000-4-4,
Niveau 2
IEC 61000-4-4,
Niveau 1
Onde de choc Salves IEC 61000-4-5
(hors fonctionnement)
Immunité aux Immunité aux IEC 61000-4-6
perturbations perturbations
conduites conduites
(hors fonctionnement)
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 41 –

Groupes Essais Sévérité Références


Mise à la terre Mise à la terre GR-1089,
(hors fonctionnement) Chapitre 9

A.5 Essais d'intégrité des fibres

Le Tableau A.4 donne les éléments d'essai et la sévérité des essais d’intégrité des fibres.
Ces types d'essais sont communs pour les modules à fibre amorce. Il convient de noter que
certains essais nécessitent un contrôle au cours de leur déroulement. Il est recommandé
d'examiner les méthodes et les procédures de montage lors du choix de l'essai.

Tableau A.4 – Eléments d'essai de l'intégrité des fibres et leurs sévérités

Groupes Essais Sévérités Références


Rétention Rétention du câble 0,45 kgf pour les fibres sous protection, 5 s, 3 fois GR-1209
du câble (hors 0,45 kgf pour les revêtements protecteurs serrés,
fonctionnement) 5 s, 3 fois
1 kgf pour les revêtements protecteurs lâches, 5 s,
3 fois
1 kgf pour les types renforcés, 5 s,3 fois
Rétention du câble 2 N pour revêtement primaire IEC 61753-1, cat C,
à fibres (en 5 N pour revêtement secondaire IEC 61300-2-4
fonctionnement) 10 N pour câbles renforcés
120 s durée pour 10 N
60 s durée pour 2 N et 5 N
Flexion de Flexion de la fibre 0,45 kgf, 30 cycles en cas de revêtement, GR-1209
la fibre (hors revêtement protecteur serré, revêtement
fonctionnement) protecteur lâche,
0,45 kgf, 300 cycles pour les cas renforcés
Flexion de la fibre 2 N pour les cas renforcés, ± 90°, 30 cycles IEC 61753-1, cat C,
(en fonctionnement) IEC 61300-2-44
Torsion des Torsion de la 0,45 kgf 10 cycles en cas de revêtement, GR-1209
fibres fibre (hors revêtement protecteur serré, revêtement
fonctionnement) protecteur lâche, cas renforcés
Torsion (hors 5,0 N à 0,1 N/s pour les cas renforcés IEC 61753-1, cat O,
fonctionnement) 2,0 N à 0,1 N/s for pour les revêtements primaires IEC 61300-2-5
et secondaires 10 cycles ±180 °
Traction Traction latérale 0,23 kgf 90° 5 s, 2 directions pour les revêtements GR-1209
latérale de de la fibre (hors protecteurs serrés, 0,45 kgf, 90°, 5 s pour les
la fibre fonctionnement) revêtements protecteurs lâches, cas renforcés
Charge latérale 1 N pendant 1 h pour les câbles renforcés 0,2 N IEC 61753-1, cat C,
statique (en pendant 5 min pour les fibres sous revêtement IEC 61300-2-42
fonctionnement) secondaire, deux directions perpendiculaires l’une
par rapport à l’autre
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
– 42 – IEC 62343-2:2014 © IEC 2014

Bibliographie

IEC 60050-731, Vocabulaire Électrotechnique International – Chapitre 731:


Télécommunications par fibres optiques

IEC 61000-4-2, Compatibilité électromagnétique (CEM) – Partie 4-2: Techniques d'essai et de


mesure − Essai d'immunité aux décharges électrostatiques

IEC 61000-4-3, Compatibilité électromagnétique (CEM) – Partie 4-3: Techniques d'essai et de


mesure – Essai d’immunité aux champs électromagnétiques rayonnés aux fréquences
radioélectriques

IEC 61000-4-4, Compatibilité électromagnétique (CEM) – Partie 4-4: Techniques d'essai et de


mesure − Essai d'immunité aux transitoires électriques rapides en salves

IEC 61000-4-5, Compatibilité électromagnétique (CEM) – Partie 4-5: Techniques d'essai et de


mesure − Essai d'immunité aux ondes de choc

IEC 61000-4-6, Compatibilité électromagnétique (CEM) – Partie 4-6: Techniques d'essai et de


mesure − Immunité aux perturbations conduites induites par les champs radioélectriques

IEC 61291-5-2, Amplificateurs optiques – Partie 5-2: Spécifications de qualification –


Qualification de fiabilité pour amplificateurs à fibres optiques

IEC 61300-2-5, Dispositifs d'interconnexion et composants passifs à fibres optiques –


Méthodes fondamentales d'essais et de mesures – Partie 2-5: Essais – Torsion

IEC 61300-2-9, Dispositifs d'interconnexion et composants passifs à fibres optiques –


Méthodes fondamentales d'essais et de mesures – Partie 2-9: Essais – Chocs

IEC 61300-2-42, Dispositifs d'interconnexion et composants passifs à fibres optiques –


Procédures fondamentales d'essais et de mesures – Partie 2-42: Essais – Charge latérale
statique pour serre-câble

IEC 61300-2-44, Fibre optic interconnecting devices and passive components – Basic test
and measurement procedures – Part 2-44: Tests – Flexing of the strain relief of fibre optic
devices
(disponible en anglais seulement)

IEC 61753-1, Norme de qualité de fonctionnement des dispositifs d'interconnexion et


composants passifs à fibres optiques – Partie 1: Généralités et lignes directrices pour
l’établissement des normes de qualité de fonctionnement

IEC TR 61931, Fibres optiques – Terminologie

IEC 62343-6-5, Dynamic modules – Part 6-5: Design guide – Investigation of operating
mechanical shock and vibration tests for dynamic devices
(disponible en anglais seulement)

CISPR 22, Appareils de traitement de l'information – Caractéristiques des perturbations


radioélectriques – Limites et méthodes de mesure

EN 55022, Appareils de Traitement de l'Information – Caractéristiques des perturbations


radioélectriques – Limites et méthodes de mesure

FCC Radio 47, Part 15, Communications equipment Computer technology


Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
IEC 62343-2:2014 © IEC 2014 – 43 –

Telcordia GR-63, NEBS(TM) Requirements: Physical Protection

Telcordia GR-1089:2011, Electromagnetic Compatibility and Electrical Safety − Generic


Criteria for Network Telecommunications Equipment

Telcordia GR-1209, Generic Requirements for Passive Optical Components

Telcordia GR-1221, Generic Reliability Assurance Requirements for Passive Optical


Components

Telcordia GR-1312, Generic Requirements for Optical Fiber Amplifiers and Proprietary Dense
Wavelength-Division Multiplexed Systems

Telcordia TR-NWT-000870, Electrostatic Discharge Control in the Manufacture of


Telecommunications Equipment

____________
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
Copyrighted material licensed to BR Demo by Thomson Reuters (Scientific), Inc., subscriptions.techstreet.com, downloaded on Nov-27-2014 by James Madison. No further reproduction or distribution is permitted. Uncontrolled when printe
ELECTROTECHNICAL

Tel: + 41 22 919 02 11
Fax: + 41 22 919 03 00
INTERNATIONAL

CH-1211 Geneva 20
3, rue de Varembé
COMMISSION

PO Box 131

info@iec.ch
Switzerland

www.iec.ch