30lbe51br411-Rev 1
30lbe51br411-Rev 1
30lbe51br411-Rev 1
NPD Weight
Description Qty
[DN] [Kg]
N
A A
INSULATION:
INS_HC_180 INSULATION:
INS_HC_100
167MM BEND RADIUS 167
+X=-1160/13-30UMY01
+Y=+1619/B-30UMY01 7
26
B +Z=+1532 B
10 6
0
0 7.3 230
10
4
1.8
1.6 5
20
0 38
2.1 5
C C
30LBE51AA411
STEM S 88.57 U INSULATION:
07-0025-228 INS_HC_100
1.9
S5.1
INSULATION:
RH-02
08 230 INS_HC_50
28 S3.2
US-03A 1 PIPE-SMLS, S-STD, A335-P11, ASME-B36.10M 25 7.4 M 18.4
2 THROTTLE VALVE, CL1500, A182-F22, ASME B16.34 25 2 15.0
75 7 8 3 UNDER SUPPORT 25 2 -
167MM BEND RADIUS 21 4 GUIDE SUPPORT 25 1 -
+X=-4400/13-30UMY01 2.2 5 RIGID HANGER 25 1 -
+Y=+1619/B-30UMY01 30LBE51AA412 6 PIPE BEND 5D RADIUS (88.6 DEG), S-STD, A335-P11, 25 0.6 M 1.3
D +Z=+1613 STEM S 88.57 U ASME-B36.10M
D
14
07-0025-228 20 7 PIPE BEND 5D RADIUS (90.0 DEG), S-STD, A335-P11, 25 0.8 M 2.0
ASME-B36.10M
163
167
S4.1
7
66 GS-03A
163
167
E E
167MM BEND RADIUS
6.2 +X=-1160/13-30UMY01
10 +Y=-1075/B-30UMY01
0 +Z=+1464
40.0
PENGERANG POWER SDN BHD
7.2 (Company No. 1089490-K)
25NPD
626
Level 51, Tower 2, PETRONAS Twin Towers
1.11
Kuala Lumpur City Centre
3 50088 Kuala Lumpur, Malaysia
SEE ISO
F 30LBE51BR002 1.4 F
+X=+3650/12-30UMY01
+Y=+120/B-30UMY01 10 PETRONAS PETRONAS TECHNICAL SERVICES SDN BHD
66 TECHNICAL
+Z=+1961 (Company No. 347848-X)
CONN TO SERVICES
Tower 1, PETRONAS Twin Towers
30GMY10BZ002-H12 Kuala Lumpur City Centre
1 25, Loose connection
S3.1 50088 Kuala Lumpur, Malaysia
+X=-1160/13-30UMY01
US-03A
+Y=-1075/B-30UMY01
167MM BEND RADIUS +Z=+675
25NPD
40 167 +X=-4400/13-30UMY01
0 +Y=+120/B-30UMY01
+Z=+1650
G G
7.1
124
1.2 0
10
167
SEONGHWA
167MM BEND RADIUS Industrial Co., Ltd
+X=+3650/12-30UMY01
163
+Y=+120/B-30UMY01 PCP-SAG-PIP-ISO-LBE-479533
+Z=+1674 Ursprung/Original Ursprung-Nr./Original-No. REV Urspr.-PKZ-Nr.
J Orig.-PC J
MY1008-30LBE51-&MTB020-111492 00/00
446539331 &MTC030
INCH-DIA
K 30LBE51BR411 K
SHOP 0 479533
FIELD 8.4 L/M SPISO PLMS-P
01_00 2016-07-01 S.W.Kim J.W.Han REVISED AS MARKED
THK THK THK FIELD SHOP 00_01 2016-04-21 S.W.Kim J.W.Han FIRST ISSUE
(mm) (mm) (mm) in% BW SW RFN FIL in% BW SW RFN FIL Definition 00_00 2016-05-26 S.W.Kim J.W.Han RELEASED FOR EXECUTION
1 25 F BW 33.4 3.38 No R 100 0 0 0 R 100 0 0 0 Radiographic Examination
2 25 F BW 33.4 3.38 No U 0 0 0 0 U 0 0 0 0 Ultasonic Examination.
80
3 25 F BW 33.4 3.38 No P P Liquid Penetration Examination
0 0 0 0 0 0 0 0
4 25 F BW 33.4 3.38 No - -
S 100 100 100 100 S 100 100 100 100 Magnetic Examination
5 25 F BW 33.4 3.38 No
L 6 25 F BW 33.4 3.38 No H 0 0 0 0 H 0 0 0 0 Hardness Testing
7 25 F BW 33.4 3.38 No M 10 0 10 10 M 10 0 10 10 Metascope or ferritic check 2016-04-21 M.J.Shin Piping
8 25 F BW 33.4 3.38 No V V Visual Examination 2016-04-21 S.W.Kim
Exportkennzeichnung AL: ECCN:
Remarks
100 100 100 100 100 100 100
The extent of NDE is mandatory for shop and field welds of the
100
2016-04-21 J.W.Han
Isometric 30LBE51BR411
respective piping system as a designated lot.
Bearbeitung dieses Dokumentes, Verwertung und Mitteilung
- Final dimensions of valves and in- line components to be
checked by erection contractor before installation. General Weld type Addition for extent of NDE below 100%: All materials, all nominal pipe sizes Building: 30UMY
gestattet. Zuwiderhandlungen verpflichten zu Schadenersatz.
- Pipe routing NPS < 3" (DN80) should be Position number acc. partlist BW : Butt weld and all welders shall be considered for a random spot examination of welds
bzw bei Kennzeichen "AL:N" oder "ECCN:N", kann sich eine Genehmigungspflicht, unter anderem
checked by erection contractor at site Shop weld number SW : Socket weld Set of Rules for
oder Geschmacks-mustereintragung vorbehalten. Insulation 180 mm
- All pipes without fit-up allowance Field weld number O-LET : Weldolet, sockolet Construction
Transmittal, reproduction, dissemination and/or editing of this Export classification AL: ECCN: - Fit-up allowance of pipe = 150mm, Support type RFN : Reinforce Nozzle
Pipe Material Class A90A1RA0120 max. allow. work. Temperature 470 C 01_00
M document as well as utilization of its contents and Goods labeled with "AL not equal to N" are subject to European or German export authorization which is additional marked with "+150" KKS-support number FIL : Fillet
20
communication thereof to others without express authorization when being exported out of the EU. Goods labeled with "ECCN not equal to N" are subject to US - For Part No. only figure before dot to be Slope SF : Socket Fusion MY1008-30LBE51-&MTC030-479533
are prohibited. Offenders will be held liable for payment of matched with BOM Part No.
Internal Coating max. allow. work. Pressure 67 bar
reexport authorization. Even without a label, or with label "AL:N" or"ECCN:N", authorization may be Flow direction F : Field weld
damages. All rights created by patent grant or registration of a - For shop pre-fabrication Referance S : Shop weld
utility model or design patent are reserved.
required due to the final whereabouts and purpose for which the goods are to be used.
drawing no. External Coating MY1008-61810-&MDC080-484504 Test Pressure 100.5 bar 1 /1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16