PRODUCT DATA SHEET

SikaLatex® R
Acrylic latex bonding agent/admixture for portland-cement mortar/concrete

PRODUCT DESCRIPTION CHARACTERISTICS / ADVANTAGES


SikaLatex® R is an acrylic-polymer latex. It is not re- ▪ Concrete/Mortar/Grout/etc. containing SikaLatex® R
emulsifiable. It is a general purpose admixture which will exhibits improved adhesion to pre-pared substrates
produce polymer-modified concrete and mortar. Sika ▪ Increased adhesive strength of mortar/concrete when
Latex R is also a bonding grout when mixed with sand used as a bonding grout
and portland cement. ▪ Increased resistance to freeze/thaw durability
▪ Does not produce a vapor barrier
USES
▪ Admixture (replacing water) used in cement based
products to improve adhesion, achieve a denser
surface, and improve overall performance
▪ As a bonding grout (prime coat) when mixed with sand
and portland cement

PRODUCT INFORMATION
Packaging 1 qt. (.94 L), 6/case
1 gal. (3.8 L) jug, 4/case
5 gal. (19 L) pail
55 gal. (208 L) drum (special order)
Shelf Life 12 months in original, unopened containers
Storage Conditions Store dry at 40 to 95 °F (4 to 35 °C). Condition material to 60 to 75 °F (15 to
167 °C) before using. Protect from freezing. If frozen, discard

TECHNICAL INFORMATION
Tensile Adhesion Strength Slurry, scrub coat (ASTM C-882)
2 parts sand, 1 part cement. Tested at:
SikaLatex® R added to produce a creamy consistency. 73 °F (23 °C)
Plastic Concrete to Hardened Concrete 50 % R.H.
28 days > 500 psi (3.4 MPa) Bond Strength

APPLICATION INFORMATION

Product Data Sheet


SikaLatex® R
October 2018, Version 01.02
020301010010000098

1/3
Coverage As mixing solution: for Concrete/Mortar/Grout/etc. use neat, replacing the
amount of water typically recommended
As a bonding grout: estimated coverage based on amount of material
(sand/cement) mixed

APPLICATION INSTRUCTIONS SikaLatex® R to seal the surface.

SURFACE PREPARATION
Applying Concrete/Mortar: Remove all deteriorated
concrete, dirt, oil, grease, and all bond-inhibiting
materials from surface. Be sure repair is not less than
1/8 in. (3.2 mm) in depth. Preparation work should be
done by high pressure water blast, scabbler, or other
appropriate mechanical means to obtain an aggregate-
fractured surface with a minimum surface profile of 1/16
in. (1.6 mm). Saturate surface with clean water.
Substrate should be saturated surface dry (SSD) with no
standing water during application.
MIXING
As admixture/mixing solution: With mixer running, add
materials in the following order: SikaLatex® R solution
and then the cement based product. Replace the
amount of water recommended by the product. Do not
dilute with water.
As a bonding grout: With the mixer running, add in the
following order. SikaLatex® R solution, aggregate,
cement. The ratio is 1 part cement, 2 parts sand, and a
sufficient amount of undiluted SikaLatex® R to produce a
creamy paint consistency. Maximum 4 gal./sack of
cement (15L/sack of cement).
As a primer for acrylic coatings: No dilution is required.
Use as is.
APPLICATION METHOD / TOOLS
Admixture: Immediately trowel SikaLatex® R mortar or
concrete mix into areas to be patched. Do not over-
finish. As soon as the application is done, to prevent
damage, cure with damp burlap and/or white
pigmented polyethylene film. Curing should continue for
24 hours. Pre-testing is recommended when adding
SikaLatex® R to a specific mix design to assure the results
required.
Bonding Grout: Brush grout into area to be resurfaced
with stiff-bristled broom or scrub brush. Be sure entire
surface and all edges are coated. Apply topping
immediately over scrub coat before the bonding slurry
dries.
Primer (for acrylic coatings only): Apply undiluted
SikaLatex® R to prepared concrete substrate using
brushes, rollers, soft brooms, or spray. SikaLatex® R
must be tack-free (film formation) prior to coating.
Estimated coverage on a CSP-3 prepared surface is 300
ft2/gal. (7 m2/l) SikaLatex® R primer may be applied up to
24 hours ahead providing the area is kept dry and clean.
Very porous concrete may require a second coat of

Product Data Sheet


SikaLatex® R
October 2018, Version 01.02
020301010010000098

2/3
LIMITATIONS LEGAL DISCLAIMER
▪ Not resistant to UV rays unless painted, covered or • KEEP CONTAINER TIGHTLY CLOSED
coated. • KEEP OUT OF REACH OF CHILDREN
▪ Will not adhere to polyethylene, teflon, silicone, oils • NOT FOR INTERNAL CONSUMPTION
and greases, mold release agents and similar materials. • FOR INDUSTRIAL USE ONLY
▪ Do not expose to open flame or temperatures above • FOR PROFESSIONAL USE ONLY
120 °F (49 °C). Excessive heat can cause shorter shelf
life. Prior to each use of any product of Sika Corporation, its
▪ Not intended as a firestop. subsidiaries or affiliates (“SIKA”), the user must always
▪ Do not use where temperatures rise above 240 °F (116 read and follow the warnings and instructions on the
°C). product’s most current product label, Product Data
▪ As with all cement based materials, avoid contact with Sheet and Safety Data Sheet which are available at
aluminum to prevent adverse chemical reaction and usa.sika.com or by calling SIKA’s Technical Service
possible product failure. Insulate potential areas of Department at 1-800-933-7452. Nothing contained in
contact by coating aluminum bars, rails, posts etc. any SIKA literature or materials relieves the user of the
obligation to read and follow the warnings and
BASIS OF PRODUCT DATA instructions for each SIKA product as set forth in the
current product label, Product Data Sheet and Safety
Results may differ based upon statistical variations Data Sheet prior to use of the SIKA product.
depending upon mixing methods and equipment,
temperature, application methods, test methods, actual SIKA warrants this product for one year from date of
site conditions and curing conditions. installation to be free from manufacturing defects and
to meet the technical properties on the current Product
OTHER RESTRICTIONS Data Sheet if used as directed within the product’s shelf
life. User determines suitability of product for intended
See Legal Disclaimer. use and assumes all risks. User’s and/or buyer’s sole
remedy shall be limited to the purchase price or
ENVIRONMENTAL, HEALTH AND SAFETY replacement of this product exclusive of any labor costs.
NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL
For further information and advice regarding APPLY INCLUDING ANY WARRANTY OF
transportation, handling, storage and disposal of MERCHANTABILITY OR FITNESS FOR A PARTICULAR
chemical products, user should refer to the actual Safety PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL
Data Sheets containing physical, environmental, THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES.
toxicological and other safety related data. User must SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS
read the current actual Safety Data Sheets before using PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT
any products. In case of an emergency, call CHEMTREC OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD
at 1-800-424-9300, International 703-527-3887. BY OTHERS.

Sale of SIKA products are subject to the Terms and


Conditions of Sale which are available at
https://usa.sika.com/en/group/SikaCorp/termsandconditions.html
or by calling 1-800-933-7452.

Sika Corporation Sika Mexicana S.A. de C.V.


201 Polito Avenue Carretera Libre Celaya Km. 8.5
Lyndhurst, NJ 07071 Fracc. Industrial Balvanera
Phone: +1-800-933-7452 Corregidora, Queretaro
Fax: +1-201-933-6225 C.P. 76920
usa.sika.com Phone: 52 442 2385800
Fax: 52 442 2250537

SikaLatexR-en-US-(10-2018)-1-2.pdf

Product Data Sheet


SikaLatex® R
October 2018, Version 01.02
020301010010000098

3/3

You might also like