Designation: D 696 – 9803

Standard Test Method for


Coefficient of Linear Thermal Expansion of Plastics
Between −30°C and 30°C W with a Vitreous Silica
Dilatometer 1
This standard is issued under the fixed designation D 696; the number immediately following the designation indicates the year of
original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A
superscript epsilon (e) indicates an editorial change since the last revision or reapproval.

1. Scope*
1.1 This test method covers determination of the coefficient of linear thermal expansion for plastic materials having coefficients
of expansion greater than 1 3 10−6 1°C by use of a vitreous silica dilatometer. At the test temperatures and under the stresses
imposed, the plastic materials shall have a negligible creep or elastic strain rate or both, insofar as these properties would
significantly affect the accuracy of the measurements.
NOTE 1—There is no similar or equivalent ISO standard.
1.1.1 Test Method E 228 shall be used for temperatures other than −30°C to 30°C.
1.1.2 This test method shall not be used for measurements on materials having a very low coefficient of expansion (less than
1 3 10 −6 1°C). For materials having very low coefficient of expansion, interferometer or capacitance techniques are
recommended.
1.2 The thermal expansion of a plastic is composed of a reversible component on which are superimposed changes in length
due to changes in moisture content, curing, loss of plasticizer or solvents, release of stresses, phase changes and other factors. This
test method is intended for determining the coefficient of linear thermal expansion under the exclusion of these factors as far as
possible. In general, it will not be possible to exclude the effect of these factors completely. For this reason, the test method can
be expected to give only an approximation to the true thermal expansion.
1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory
limitations prior to use.
2. Referenced Documents
2.1 ASTM Standards:

1
This test method is under the jurisdiction of ASTM Committee D-20 on Plastics and is the direct responsibility of Subcommittee D20.30 on Thermal Properties (Section
D20.30.07).
Current edition approved Feb. April 10, 1998. 2003. Published January 1999. June 2003. Originally published as D 696 – 42. approved in 1942. Last previous edition
D 696 – 91e1. approved in 1998 as D 696 – 98.

*A Summary of Changes section appears at the end of this standard.


Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.

1
D 696 – 9803
D 618 Practice for Conditioning Plastics and Electrical Insulating Materials for Testing2
D 883 Terminology Relating to Plastics2
D 1898 Practice for Sampling of Plastics2
D 4065 Practice for Determining and Reporting Dynamic Mechanical Properties of Plastics3
E 228 Test Method for Linear Thermal Expansion of Solid Materials with a Vitreous Silica Dilatometer4
E 691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method4
E 831 Test Method for Linear Thermal Expansion of Solid Materials by Thermomechanical Analysis4

3. Terminology
3.1 Definitions—Definitions are in accordance with Terminology D 883 unless otherwise specified.

4. Summary of Test Method


4.1 This test method is intended to provide a means of determining the coefficient of linear thermal expansion of plastics which
are not distorted or indented by the thrust of the dilatometer on the specimen. For materials that may indent, see 8.4. The specimen
is placed at the bottom of the outer dilatometer tube with the inner one resting on it. The measuring device which is firmly attached
to the outer tube is in contact with the top of the inner tube and indicates variations in the length of the specimen with changes
in temperature. Temperature changes are brought about by immersing the outer tube in a liquid bath or other controlled temperature
environment maintained at the desired temperature.

5. Significance and Use


5.1 The coefficient of linear thermal expansion, a, between temperatures T1 and T2 for a specimen whose length is L 0 at the
reference temperature, is given by the following equation:
a 5 ~L2 2 L 1!/@L0~T22T1!# 5 DL/L 0DT
where L1 and L2 are the specimen lengths at temperatures T1 and T2, respectively. a is, therefore, obtained by dividing the linear
expansion per unit length by the change in temperature.
5.2 The nature of most plastics and the construction of the dilatometer make −30 to +30°C ( [−22°F to +54°F)] a convenient
temperature range for linear thermal expansion measurements of plastics. This range covers the temperatures in which plastics are
most commonly used. Where testing outside of this temperature range or when linear thermal expansion characteristics of a
particular plastic are not known through this temperature range, particular attention shall be paid to the factors mentioned in 1.2
and special preliminary investigations by thermo-mechanical analysis, such as that prescribed in Practice D 4065 for the location
of transition temperatures, may be required to avoid excessive error. Other ways of locating phase changes or transition
temperatures using the dilatometer itself may be employed to cover the range of temperatures in question by using smaller steps
than 30°C (54°F) [54°F] or by observing the rate of expansion during a steady rise in temperature of the specimen. Once such a
transition point has been located, a separate coefficient of expansion for a temperature range below and above the transition point
shall be determined. For specification and comparison purposes, the range from −30°C to +30°C ( [−22°F to +86°F)] (provided
it is known that no transition exists in this range) shall be used.

6. Apparatus
6.1 Fused-Quartz-Tube Dilatometer suitable for this test method is illustrated in Fig. 1. A clearance of approximately 1 mm is
allowed between the inner and outer tubes.
6.2 Device for measuring the changes in length (dial gage, LVDT, or the equivalent) is fixed on the mounting fixture so that its
position may be adjusted to accommodate specimens of varying length (see 8.2). The accuracy shall be such that the error of
indication will not exceed 61.0 µm ( [4 3 10 −5 in.)] for any length change. The weight of the inner silica tube plus the measuring
device reaction shall not exert a stress of more than 70 kPa (10 psi) [10 psi] on the specimen so that the specimen is not distorted
or appreciably indented.
6.3 Scale or Caliper capable of measuring the initial length of the specimen with an accuracy of 60.5 %.
6.4 Controlled Temperature Environment to control the temperature of the specimen. Arrange the bath so a uniform temperature
is assured over the length of the specimen. Means shall be provided for stirring the bath and for controlling its temperature within
60.2°C ( [60.4°F)] at the time of the temperature and measuring device readings.
NOTE 2—If a fluid bath is used, it is preferable and not difficult to avoid contact between the bath liquid and the test specimen. If such contact is
unavoidable, take care to select a fluid that will not affect the physical properties of the material under test.
6.5 Thermometer or Thermocouple —The bath temperature shall be measured by a thermometer or thermocouple capable of
an accuracy of 60.1°C ( [60.2°F)].

2
Annual Book of ASTM Standards, Vol 08.01.
3
Annual Book of ASTM Standards, Vol 08.02.
4
Annual Book of ASTM Standards, Vol 14.02.

2
D 696 – 9803

FIG. 1 Quartz-Tube Dilatometer

7. Sampling
7.1 Unless otherwise specified, the material
7.1 Sampling shall be sampled as described conducted in Sections 8 through 14 of Practice D 1898. accordance with the
material specification for the material in question.
8. Test Specimen
8.1 The test specimens may shall be prepared by machining, molding, or casting operations under conditions which that give
a minimum of strain or anisotropy. If anisotropy is suspected on the samples, cut the specimens along the principal axes of
anisotropy and the coefficient of linear thermal expansion shall be measured on each set of specimens. Annealing of the specimens
may remove anisotropy effects due to processing anisotropy, such as machining, molding, or casting opreparations.
8.2 The specimen length shall be between 50 mm and 125 mm.
NOTE 3—If specimens shorter than 50 mm are used, a loss in sensitivity results. If specimens greatly longer than 125 mm are used, the temperature
gradient along the specimen may become difficult to control within the prescribed limits. The length used will be governed by the sensitivity and range
of the measuring device, the extension expected and the accuracy desired. Generally speaking, the longer the specimen and the more sensitive the
measuring device, the more accurate will be the determination if the temperature is well controlled.
8.3 The cross section of the test specimen may be round, square, or rectangular and should shall fit easily into the measurement
system of the dilatometer without excessive play on the one hand or friction on the other. The cross section of the specimen shall
be large enough so that no bending or twisting of the specimen occurs. Convenient specimen cross sections are: 12.5 by 6.3 mm
( [1⁄2 in. by 1⁄4 in.)], 12.5 by 3 mm ( [1⁄2 by 1⁄8 in.)], 12.5 mm ( [1⁄2 in.)] in diameter or 6.3 mm ( [1⁄4 in.)] in diameter. If excessive
play is found with some of the thinner specimen, guide sections may shall be cemented or otherwise attached to the sides of the
specimen to fill out the space.
8.4 Cut the ends of the specimens flat and perpendicular to the length axis of the specimen. Protect If a specimen indents from
the ends against indentation by means use of the dilatometer, then flat, thin steel or aluminum plates shall be cemented or otherwise

3
D 696 – 9803
firmly attached to them before the specimen is placed to aid in positioning it in the dilatometer. These plates shall be 0.3 to 0.5
mm ( [0.012 to 0.020 in.)] in thickness.
9. Conditioning
9.1 Conditioning— Condition the test specimens at 23 6 2°C ( [73.4 6 3.6°F)] and 50 6 5 % relative humidity for not less than
40 h prior to test in accordance with Procedure A of Practice D 618 unless otherwise specified by the contract or relevant material
specification. In cases of disagreement, the tolerances shall be 61°C ( [61.8°F)] and 62 % relative humidity.
9.2 Test Conditions— Conduct tests in the Standard Laboratory Atmosphere of 23 6 2°C ( [73.4 6 3.6°F)] and 50 6 5 %
relative humidity, unless otherwise specified by the contract or relevant material specification. In cases of disagreement, the
tolerances shall be 61°C ( [61.8°F)] and 62 % relative humidity.
10. Procedure
10.1 Measure the length of two conditioned specimens at room temperature to the nearest 25 µm ( [0.001 in.)] with the scale
or caliper (see 6.3).
10.2 Cement or otherwise attach the steel plates to the ends of the specimen to prevent indentation (see 8.4). Measure the new
lengths of the specimens.
10.3 Mount each specimen in a dilatometer. Carefully install the dilatometer in the −30°C (−22°F) [−22°F] controlled
environment. If liquid bath is used, make sure the top of the specimen is at least 50 mm (2 in.) [2 in.] below the liquid level of
the bath. Maintain the temperature of the bath in the range from −32°C to −28°C ( [−26 to −18°F)] 6 0.2°C ( [0.4°F)] until the
temperature of the specimen along the length is constant as denoted by no further movement indicated by the measuring device
over a period of 5 to 10 min. Record the actual temperature and the measuring device reading.
10.4 Without disturbing or jarring the dilatometer, change to the +30°C (+86°F) [+86°F] bath, so that the top of the specimen
is at least 50 mm (2 in.) [2 in.] below the liquid level of the bath. Maintain the temperature of the bath in the range from +28 to
32°C ( [+82 to 90°F)] 6 0.2°C ( [60.4°F)] until the temperature of the specimen reaches that of the bath as denoted by no further
changes in the measuring device reading over a period of 5 to 10 min. Record the actual temperature and the measuring device
reading.
10.5 Without disturbing or jarring the dilatometer, change to −30°C (−22°F) [−22°F] and repeat the procedure in 10.3.
NOTE 4—It is convenient to use alternately two baths at the proper temperatures. Great care should be taken not to disturb the apparatus during the
transfer of baths. Tall Thermos bottles have been successfully used. The use of two baths is preferred because this will reduce the time required to bring
the specimen to the desired temperature. The test should be conducted in as short a time as possible to avoid changes in physical properties during long
exposures to high and low temperatures that might possibly take place.
10.6 Measure the final length of the specimen at room temperature.
10.7 If the change in length per degree of temperature difference due to heating does not agree with the change in length per
degree due to cooling within 10 % of their average, investigate the cause of the discrepancy and, if possible, eliminate. Repeat the
test until agreement is reached.
11. Calculation
11.1 Calculate the coefficient of linear thermal expansion over the temperature range used as follows:
a 5 DL/L0DT

a = average coefficient of linear thermal expansion per degree Celsius,


DL = change in length of test specimen due to heating or to cooling,
L0 = length of test specimen at room temperature (DL and L0 being measured in the same units), and
DT = temperature differences, °C, over which the change in the length of the specimen is measured.
The values of a for heating and for cooling shall be averaged to give the value to be reported.
NOTE 5—Correction for thermal expansion of silica is 4.3 3 10 −7 1°C. If requested, this value should be added to the calculated value to compensate
for the expansion of the apparatus equivalent to the length of the specimen. If thick metal plates are used, appropriate correction may also be desirable
for their thermal expansions.

12. Report
12.1 The report shall include the following:
12.1.1 Designation of material, including name of manufacturer and information on composition when known.
12.1.2 Method of preparation of test specimen,
12.1.3 Form and dimensions of test specimen,
12.1.4 Type of apparatus used,
12.1.5 Temperatures between which the coefficient of linear thermal expansion has been determined,
12.1.6 Average coefficient of linear thermal expansion per degree Celsius, for the two specimens tested.
12.1.7 Location of phase change or transition point temperatures, if this is in the range of temperatures used,

4
D 696 – 9803
12.1.8 Complete description of any unusual behavior of the specimen, for example, differences of more than 10 % in measured
values of expansion and contraction.
13. Precision and Bias
13.1 Table 1 is based on a round robin conducted in 1989 in accordance with Practice E 691 involving nine materials and five
laboratories. For each material, all samples are prepared at one source, but the individual specimens are prepared at the laboratory
that tested them. Each test result is the average of two individual determinations. Each laboratory obtained one test result for each
material.
NOTE 6—Caution: material. Warning—The explanations of “r” and “R” (13.2-13.2.3) only are intended to present a meaningful way of considering
the approximate precision of this test method. The data presented in Table 1 should not be applied to the acceptance or rejection of materials, as these
data apply only to the materials tested in the round robin and are unlikely to be rigorously representative of other lots, formulations, conditions, materials,
or laboratories. In particular, with data from less than six laboratories, the between laboratories results are likely to have a very high degree of error. Users
of this test method should apply the principles outlined in Practice E 691 to generate data specific to their materials and laboratory, or between specific
laboratories. The principles of 13.2-13.2.3 then would be valid for such data.
13.2 Concept of “r” and “R” in Table 1—If Sr and SR have been calculated from a large enough body of data, and for test results
that are averages from testing five specimens for each test result, then the following applies:
13.2.1 Repeatability “r” is the interval representing the critical difference between two test results for the same material,
obtained by the same operator using the same equipment on the same day in the same laboratory. Two test results shall be judged
not equivalent if they differ by more than the “ r” value for that material.
13.2.2 Reproducibility “R” is the interval representing the critical difference between two test results for the same material,
obtained by different operators using different equipment in different laboratories, not necessarily on the same day. Two tests results
shall be judged to be judged not equivalent if they differ by more than the “R” value for that material.
13.2.3 Any judgement in accordance with 13.2.1 or 13.2.2 would have an approximate 95 % (0.95) probability of being correct.
13.3 There are no recognized plastic reference materials to estimate bias of this test method; however, there are recognized
metal and ceramic reference materials.
14. Keywords
14.1 coefficient of expansion; linear expansion; plastics; thermal expansion

SUMMARY OF CHANGES

This section identifies the location of selected changes to this test method. For the convenience of the user,
Committee D-20 has highlighted those changes that may impact the use of this test method. This section may
also include descriptions of the changes or reasons for the changes, or both.

D 696 – 03:

TABLE 1 Coefficient of Linear Expansion, 10−6


No. of
Material Average SrA SRB rC RD Participating
Laboratories
Polyester-Glass 24.7 1.80 4.91 5.04 13.75 5
Phenolic-Glass 34.2 1.18 2.63 3.29 7.36 5
Epoxy-Glass 26.1 1.27 2.74 3.55 7.69 5
Polypropylene 158.2 3.38 12.20 9.47 34.20 5
Polyethylene 63.0 0.454 1.73 1.27 4.80 5
Polycarbonate 113.0 2.48 4.77 6.95 13.36 5
Nylon 66 130.7 2.83 7.63 7.92 21.4 5
PTFE 207.0 18.7 42.7 52.4 119.5 4
Expanded 117.2 16.7 25.9 46.8 72.5 4
Polypropylene
Beads, Density
4.40 PCF
A
Sr = within-laboratory standard deviation for the indicated material. It is
obtained by pooling the within-laboratory standard deviations of the test result from
all the participating laboratories:
Sr = [[( S1)2 = (S2)2 . . .( Sn)2]/n]1/2
B
SR = between-laboratories reproducibility, expressed as standard deviation:
SR = (Sr2 + S2)1/2
C
r = within-laboratory critical interval between two test results = 2.8 3 Sr
D
R = between laboratories critical interval between two test results = 2.8 3 SR

5
D 696 – 9803
(1) Removed permissive language throughout.
(2) Revised paragraph 8.4.
(3) Removed Practice D 1898 from Referenced Documents. There is no reference to it within the standard and it has been
withdrawn.
D 696 – 98:
(1) Change in title to add “With a Vitreous Silica Dilatometer.”
(2) Addition of Note 1.
(3) Updated Section 9.
(4) Updated Section 13.
(5) Added Summary of Changes section.

ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.

This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above