A7 New
A7 New
A7 New
-E-10V24
Soft start/quick exhaust valve
Instructions |
Assembly, Installation,
Safety func.
8111049
8111049
2019-10d
[8111051]
Translation of the original instructions
1 Applicable documents
2 Safety
2.1 Safety Instructions
– Only use the product in original status without unauthorised modifications.
– Only use the product if it is in perfect technical condition.
– Observe labelling on the product.
– Take into consideration the ambient conditions at the location of use.
– Prior to mounting, installation and maintenance work: Switch off power supply and secure it from
being switched back on.
– Observe tightening torques. Unless otherwise specified, the tolerance is ± 20 %.
– The product must be operated only with the specified multi-pin plug sockets NECA-S1G9-P9-MP....
– Non-compliance with the information in this instruction manual can lead to loss of the safety func-
tion.
The product is intended for installation in a machine or automated system and must be used exclus-
ively as follows:
– In an industrial environment
– Within the limits of the product defined by the technical data è 14 Technical Data.
– In its original condition, without unauthorised modifications
– In perfect technical condition
– In standard operation, which includes standstill, set-up and service operation, as well as emer-
gency operation
3 Additional information
– Accessories è www.festo.com/catalogue.
– Spare parts èwww.festo.com/spareparts.
4 Service
Contact your regional Festo contact person if you have technical questions è www.festo.com.
5 Product Overview
5.1 Design
5.1.1 Product design
The product corresponds to category 4 with a maximum achievable performance level e in accordance
with EN ISO 13849-1.
Series M Modular
Power class S Standard
Size 6 Housing width 62 mm
Function – SV Soft-start/quick exhaust valve, electric
Connection size – 1/2 G1/2
– AGB G1/4
– AGC G3/8
– AGD G1/2
– AGE G3/4
– AQN NPT1/4
– AQP NPT3/8
– AQR NPT1/2
– AQS NPT3/4
Performance level –E In accordance with EN ISO 13849-1, category 4
2-channel with self-monitoring, safety device in accordance
with EC Machinery Directive 2006/42/EG
supply voltage – 10V24 24 V DC
Options1) – SO Silencer open
5.2 Function
The product is a safe, redundant mechatronic system in accordance with the requirements of EN ISO
13849-1+2. The safe venting pneumatic safety function is guaranteed even in the event of an error in
the valve (e.g. due to wear or contamination). Through its electrical connection (NECA multi-pin plug
socket Sub-D, 9-pin), the product receives secure enable signals (EN1/EN2) from commercially-avail-
able electronic or electromechanical safety relay units, which monitor the machine’s protective
devices (e.g. emergency stop, light curtain, electric door switch on the protective housing, etc.).
The impulse generated by the start button must be within a time-frame of 0.1 s and 2 s.
If the start button is held down for too long or is locked down, the system identifies a cross circuit and
the product is placed in fault mode.
The start signal for S34 must not be generated until 1 s after the enable signals EN1/EN2 are gener-
ated.
If the start signal is generated before or simultaneously with the enable signals, it will not be recog-
nised and must be generated again.
Operational principle of the multi-pin plug sockets NECA-…-MP1, -MP3 und -MP5
Status of Status of Status of valve Status of valve Status of valve with NECA-…-MP5
EN1 EN2 with NECA-…- with NECA-…-
MP1 MP3
by safety relay unit/PLC (clocked sig- by product by safety relay unit/PLC (potential dif-
nals) ference monitoring)
Tab. 4 Detection of shorts across contacts
Connection examples
MS6-SV-E with multi-pin plug socket NECA-S1G9-P9-MP1
The clock outputs of different controller manufacturers are not standardised. The usability must be
checked in every case. If the clock pulse is outside the described limits, this is recognised by the
product as an error and a safe switch-off is carried out.
The multi-pin plug socket NECA-S1G9-P9-MP3 is intended for conventional circuitry with electromech-
anical safety relays. If problems arise in use with bipolar semiconductor outputs, use the multi-pin
plug socket NECA-S1G9-P9-MP5.
The time delay t2 between EN1 and EN2 must be automatically defined. The duration of the delay is
not evaluated. The multi-pin plug socket NECA-MP5 does not enable the product to detect shorts
across contacts.
Signal contact
The signal contact is a potential-free N/O contact of a semiconductor relay. The contact can be picked
up in the feedback circuit of a safety control system through terminals 3 and 4 of the NECA multi-pin
plug socket as required.
NOTICE!
If the signal contact is operated outside the permitted technical data, this will cause irreparable fail-
ure. Compliance with the specification must be ensured through an appropriate protective circuit.
NOTICE!
Assignment of these contacts is not required to achieve the safety category.
Switching behaviour diagrams, with multi-pin plug socket NECA-S1G9-P9-MP1 è Fig.20 and with
multi-pin plug socket NECA-S1G9-P9-MP3/MP5 è Fig.23.
Example:
At an operating pressure of p1 = 4 bar with reference to the approved tolerance of ± 20% a switch-
through pressure of 1.2 to 2.8 bar is permissible.
NOTICE!
NOTICE!
NOTICE!
The electro-pneumatic soft-start/quick exhaust valve has control technology features which enable
performance level e to be reached for the safety functions. This product has been designed and manu-
factured in accordance with the fundamental and reliable safety principles of EN ISO 13849-2.
The following requirements apply to the manager:
– Specifications on mounting and operating conditions in these operating instructions must be
observed.
– For use in higher categories (2 to 4), the requirements of EN ISO 13849, e.g. CCF, must be con-
sidered.
– The basic and proven safety principles of EN ISO 13849-2 relating to implementation and opera-
tion of the component must be satisfied.
– When using this product in machines or systems subject to specific C standards, it must be in
compliance with the requirements specified in the standards.
– Before using the product, a risk assessment in accordance with EN ISO 12100 as specified in the
EC Machinery Directive 2006/42/EG, appendix I, paragraph 1 and 1.1.2 is required.
– The user is responsible for coordinating all applicable safety regulations and rules with the com-
petent authority and for compliance with regulations and rules.
Failures due to a common cause (Common Cause Failure – CCF)
The following measures ensure that common cause failures are avoided:
– Compliance with the permissible values for vibration and shock stress
– Compliance with the temperature range
– Compliance with compressed air quality as specified in the technical data, in particular avoiding
flash rust particles (such as caused by servicing work) as well as compliance with the residual oil
content of max. 0.1 mg/m3 when using ester-containing oils (which may, for example, be con-
tained in the compressor oil)
– Compliance with the maximum operating pressure, if necessary with a pressure-relief valve
– Clogging of the silencer must be avoided .
PFHd value
The PFHd value depends on the model of the product and the annual actuation rate (nop).
6 Assembly
6.1 Requirement
– Take appropriate measures to remove any particles in the supply lines.
6.2 Preparation
NOTICE!
In order to ensure electromagnetic compatibility in accordance with the EMC Directive, note the follow-
ing:
• Ensure a wall clearance of 32 mm, e.g. with the MS6-WPB mounting bracket.
• Do not lay cables between the wall and the product.
NOTICE!
Fig. 13 Installation
– Observe the flow direction 1 to 2. The numerals 1 on the product housing serve as orientation.
Fig. 15 Assembly
1. Slide the cover cap MS6-END 1 upwards and remove it.
2. Insert a seal 2 between the individual devices (module connector MS6-MV in scope of delivery).
3. Place module connector 2 in the slots of the individual devices.
4. Fasten the module connector with two screws (product scope of delivery). Tightening torque: max-
imum1.2 Nm.
7 Installation
7.1 Pneumatic Installation
Port 1 and 2
If using screw connectors:
– Note the screw-in depth of the connector thread: 10 mm.
– Make sure that the compressed air lines are connected correctly.
– Screw the connectors into the pneumatic connections using a suitable sealing material.
Connection 3
NOTICE!
The product may only be used with the approved NECA multi-pin plug sockets NECA-... .
Information on terminal connections can be found in the assembly instructions enclosed with the
multi-pin plug socket.
When mounting the multi-pin plug sockets NECA-... with enclosed seal, note the correct position of the
plug with reference to the valve. The display window of the multi-pin plug socket NECA-... must point
forward.
8 Commissioning
For easier commissioning, we recommend planning a reset button (normally closed) in the power sup-
ply circuit. This simplifies a reset in case of error.
The valve is tested pneumatically in a self-test once an hour for as long as the product
remains in this status. Operating pressure p1 must be applied; otherwise, the valve switches
to malfunction.
3. Apply Enable signals EN1/EN2. In monitored start mode of operation a start signal is also required
at S34 .
– Power LED (green) lights.
– The outlet pressure p2 is built up slowly.
Duration t of the pressure build-up is adjusted with the flow control screw attached to the cover.
The output pressure rises depending on the throttle setting . When the switch-through pressure is
reached (approx. 50% of operating pressure p1), the valve’s main seat opens è Fig.11. The
product now pressurises the system at full flow.
9 Operation
The pause period after exhausting is 2 s. This period must always be complied with. Only then can
pressurisation be repeated.
10 Maintenance
10.1 Maintenance work
NOTICE!
10.2 Cleaning
1. Switch off energy sources:
– Operating voltage
– Compressed air
2. Clean the outside of the product as required. Approved cleaning agents are soap solutions (max.
+50 °C), petroleum ether and all non-abrasive cleaning agents.
11 Malfunctions
11.1 Diagnostics
LED display
Operating statuses and errors are indicated by flashing light-emitting diodes.
2 Bouncing on the enable signals – Make sure that only debounced con-
tacts are used (e.g. for protective
guards or doors).
5 Power supply is insufficient – provide sufficient power supply.
Power unit is not correctly dimensioned; – use a sufficiently dimensioned power
voltage collapses unit.
6 Pressure supply was interrupted – Restore compressed air supply.
8 Enable signals outside the specification – Comply with specification .
Multi-pin plug socket NECA or cable is – NECACheck multi-pin plug socket or
defective wiring and replace if defective.
Additional PLC emits test pulses that are offset to the – Switch off test pulses.
Error codes enable signals – Use MP5 plug connector.
Malfunction due to electrical or electro- – note maximum length of the signal
magnetic effects (EMC information not in lines.
compliance) – Connect earthing correctly.
– maintain minimum wall distance.
– Do not install cables behind the
product.
Pressure p1 The cross-section of the product pressure – Tighten flow control screw.
collapses supply is too small – Attach reservoir in front of p1 inlet.
briefly at – Adjust compressed air supply, e.g.
every increase cross section of the supply
switching line.
operation
Tab. 8 Fault clearance
12 Disassembly
1. Switch off energy sources:
– Operating voltage
– Compressed air
2. Separate the applicable connections from the product.
13 Disposal
ENVIRONMENT!
Send the packaging and product for environmentally sound recycling in accordance with the current
regulations è www.festo.com/sp.
14 Technical Data
14.1 Technical data, mechanical
MS6-SV-E
MS6-SV-E
Medium
Operating medium Compressed air according to ISO 8573-1:2010 [7:4:4]
and inert gases
Note Lubricated operation possible, in which case lubric-
ated operation will always be required
Temperature
Medium [°C] -10 … +50
Environment [°C] -10 … +50
Bearing [°C] -10 … +50
Operating pressure
Operating pressure [bar] 3.5 … 10
Residual pressure in normal [bar] 0 (no residual pressure)
operation
Residual pressure in the event [bar] £ 0.4 (at p1 = 10 bar and flow control fully open)
of error
C value [l/(s bar)] 19.3
B value 0.21
Flow rate values
Standard nominal flow rate [l/min] 4300 (at p1 = 6 bar, p2 = 5 bar)
1}2
Standard flow rate 2 } 3 [l/min] 9000 (at p1 = 6 bar
Standard flow rate 2 } 3 in the [l/min] ³ 6000 (at p1 = 6 bar)
event of a critical fault
Switch-through point Approx. 50% of p1
Filling flow Adjustable by flow control
minimum pause time after [s] ³ 2
exhaust
Tab. 10 Technical Data, Pneumatic
MS6-SV-E
Electrical connection Sub-D, 9-pin, only with multi-pin plug sockets NECA-
S1G9-P9-MP...
Degree of protection IP65 with multi-pin plug socket NECA
Protection against electric by PELV fixed power supply
shock (protection against direct
and indirect contact in accord-
ance with EN/IEC 60204-1)
Switching position indicator LED and potential-free contact
Operating voltage
Nominal operating voltage DC [V] 24
Current consumption [A] £ 0.121)
Voltage fluctuations
Permissible voltage fluctuations [%] ±10
Switching time
Switching time off [ms] 40
Switching time on [ms] 130
Duty cycle [%] 100
Semiconductor relay (signal contact)
Voltage [V] £ 60
continuous current [A] £ 0.12
Resistance in switched-on [Ω] £ 25
status
Leakage current in switched-off [µA] £ 1
status
Protection class III
1) A high starting current will apply briefly when switching on.
Tab. 11 Technical Data, Electrical
Type MS6-SV-E
NOTICE!
• Pulses at inputs EN1 and EN2 from 0 to 24 V, of £ 3 ms duration do not send an error message to
the product.
• Pulses at inputs EN1 and EN2 from 24 to 0 V, of £ 12 ms duration do not send an error message to
the product.
The following diagrams shows the exact switching characteristics of the Enable signals EN1 and EN2
with time offset. The maximum reaction time can be derived from the delay between the two signals.
Runtime performance
t1 > 5 ms: Level of EN2/EN1 must be HIGH for min. 5 ms (debounce time/input filter/stabil-
isation time).
t2 < = 75 ms: maximum permissible delay time between EN1 and EN2. If exceeded, the product
is not pressurised and an error message is output.
t3 > = 15 ms: Level of EN2/EN1 must be LOW for min. 15 ms (debounce time/input filter/sta-
bilisation time).
t4 = 2 ms: maximum internal time delay caused by the program sequence.
tp1 } 2: Pressurisation > 300 ms
tp2 } 3: Exhausting > 1 s
Tab. 14 Runtime performance
Maximum reaction time from exhausting to pressurisation: t2 + t1 + t4 = 75ms + 5ms + 2ms = 82ms
t1 > 5 ms: Level of EN2 (EN1) must be HIGH (LOW) for min. 5 ms (debounce time/input fil-
ter/stabilisation time).
t2 < = 75 ms: maximum permissible delay time between EN1 and EN2.
Exceeding maximum permissible delay time:
– Product is not pressurised and an error message is output (NECA-…-MP3)
– Product is not pressurised and an error message is output (NECA-…-MP5)
t3 > = 15 ms: Level of EN2 (EN1) must be LOW (HIGH) for min. 15 ms (debounce time/input fil-
ter/stabilisation time).
t4 = 2 ms: maximum internal time delay caused by the program sequence.
tp1 } 2: Pressurisation > 300 ms
tp2 } 3: Exhausting > 2 s
Tab. 15 Runtime performance of enable signals