Nothing Special   »   [go: up one dir, main page]

KNEE Early Outc Kinematic Retain TKR MCPS Knee 2022 Harvey

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

The Knee 39 (2022) 62–70

Contents lists available at ScienceDirect

The Knee
journal homepage:

Early outcomes using a ‘kinematic retaining’ total knee


replacement – A multicentre prospective study at two years
follow-up
Adrian R. Harvey a, Ian W. Barlow b, Christian Carulli c, Massimo Innocenti c, James O. Smith b,⇑
a
Department of Orthopaedics, University Hospitals Dorset NHS Foundation Trust, The Royal Bournemouth Hospital, Castle Lane East, Bournemouth, Dorset
BH7 7DW, UK
b
Department of Orthopaedics, Dorset County Hospital NHS Foundation Trust, Williams Avenue, Dorchester, Dorset DT1 2JY, UK
c
Orthopaedic Clinic, University of Florence, Careggi University Hospital, 50139 Florence, Italy

a r t i c l e i n f o a b s t r a c t

Article history: Background: Although predictable implant longevity in total knee replacement (TKR) is
Received 18 May 2022 now established, work continues to satisfy the demands of patients who seek full restora-
Revised 6 September 2022 tion of the painless function of the native knee following TKR. This prospective study
Accepted 11 September 2022
examines the early clinical outcomes of 156 patients implanted with a novel ‘kinematic-
retaining’ (KR) implant.
Methods: 156 Physica KR TKRs were implanted for primary osteoarthritis at three
Keywords:
European centres. Patients were reviewed up to two years using radiographic, clinical
Total knee arthroplasty
Kinematic retaining knee
and functional evaluations.
Patient reported outcomes Results: Of the 137 patients retained at two years’ follow up, none had been revised. Within
6 post-operative months, 51.7% and 79.9% had excellent clinical and functional KSS values
respectively, increasing to 81.8% and 88.3% beyond two years. Mean KSS improvement was
34.8 (from 48.6 to 83.4). All KOOS sub-scores improved significantly with total KOOS
improving from a mean of 35.5 (SD ±13.0) to 86.5 (±13.7) at two years post-operatively.
Pain and sports KOOS sub-scores improved rapidly during the early post-operative periods,
with sustained improvements beyond this. Mean OKS improved by 44.1 (±5.1) at two
years. VAS satisfaction scores improved significantly at all time points beyond six weeks.
Mean FJS-12 was 75.7 at two years, with no significant effects of age or gender. No progres-
sive adverse radiographic features were noted.
Conclusions: Early clinical and radiographic outcomes of this kinematic-retaining knee
prosthesis are promising, with improvements in clinical parameters similar to, or exceed-
ing those published in other contemporary TKR designs.
Level of evidence: II, Multicentre Prospective cohort study.
Ó 2022 The Author(s). Published by Elsevier B.V. This is an open access article under the CC
BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

1. Introduction

Total Knee Replacement (TKR) has proved to be a successful and enduring treatment for severe degenerative knee disease
[1]. Despite excellent long-term implant survivorship and incremental advances in arthroplasty design, there remains a

⇑ Corresponding author.
E-mail address: jsmith@doctors.org.uk (J.O. Smith).

https://doi.org/10.1016/j.knee.2022.09.002
0968-0160/Ó 2022 The Author(s). Published by Elsevier B.V.
This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
A.R. Harvey, I.W. Barlow, C. Carulli et al. The Knee 39 (2022) 62–70

cohort of high-demand patients who are unable to return to full activities post-operatively due to pain or poor function [2–
5]. The failure of many knee replacement designs to reproduce the kinematics of the healthy native knee may play a part in
this. The human knee is a complex joint which relies on a dynamic interplay between the incongruent joint surfaces and soft
tissue restraint for normal function during range of motion and loading [6]. This results in a characteristic ‘rollback’ of the
femur on the tibia during initial flexion with a dynamic lateral articular contact point and non-isometric ligament balance
during movement [7]. Despite this, most current TKRs have symmetric medial and lateral articulating surfaces in sagittal
profile, which does not support native knee kinematics and introduces paradoxical movement [8–10].
A key goal of new implant design for TKR is to reproduce normal kinematics after replacement and, in particular, to
achieve the initial rollback. The Physica KR (Lima Corporate Spa, Udine, Italy) is a modular posterior cruciate ligament pre-
serving knee prosthesis with a kinematic-retaining (KR) mechanism, designed to reproduce the native tibiofemoral joint
anatomy in order to restore natural knee kinematics (Figure 1). Here we report the early clinical outcomes of 156 patients
who underwent TKR using the KR knee implant.
The hypothesis formulated at the start of this study is that a knee prosthesis reproducing the tibiofemoral joint anatomy
and the kinematics of the natural knee may contribute to ensure a rapid functional recovery and excellent clinical outcomes
with superior pain relief, even in high-demand patients. This is a five year patient cohort study, we present here the inter-
mediate results at two years’ follow-up.

2. Methods

The study was designed as a post-marketing, multicentre, prospective, open-label cohort study of the CE-certified Physica
KR device with baseline control. A pre-hoc power calculation was performed with Power and Precision v4 software (Biostat,
NJ, USA). Using standard methodology with an anticipated treatment difference of 44.0 points on the KSS, with a standard
deviation of 20.0 and criterion for significance (alpha) set at 0.05, this defined the minimum sample size of 130 patients with
a power of 0.80 to reject the null hypothesis. Assuming a 20% drop-out rate, an enrolment target of 156 patients was estab-
lished. Following local and regional ethical approval 156 patients (87 men and 69 women, mean age 68 years) underwent
TKR with the Physica KR knee implant at three European sites. Patients with primary knee osteoarthritis who had not
responded to conservative treatment were recruited to the study once the decision for TKR had been made. 83 were
’high-demand’ patients with moderate or intense pre-operative activity levels. All the surgical procedures were performed
by the authors in each study site under spinal or general anaesthesia according to a standardised surgical technique. Expo-
sure was achieved through a medial parapatellar approach, bone cuts were made using proprietary jigs referenced with
intramedullary femoral and extramedullary tibial alignment. Antithrombotic and antibiotic prophylaxis was administered
according to each institution’s standard protocol.
Patients were reviewed within one month pre-operatively (T0), and post-operatively at 6 weeks (T1), 6 months (T2),
1 year (T3) and 2 years (T4) using clinical and functional performance evaluations. Knee Society Score (KSS) served as the
primary endpoint and Knee injury and Osteoarthritis Outcome Score (KOOS), Oxford Knee Score (OKS), Visual Analogue Scale

Figure 1. The Physica KR implant, designed to reproduce native tibiofemoral joint anatomy and function. The articular surface is asymmetric but congruent,
with a saddle shaped lateral tibial liner in the sagittal plane (red markings for emphasis).

63
A.R. Harvey, I.W. Barlow, C. Carulli et al. The Knee 39 (2022) 62–70

(VAS) satisfaction, Forgotten Joint Score (FJS-12) and serious adverse incidents served as secondary endpoints. Radiographic
assessment included anteroposterior, lateral and skyline projections as well as weight bearing long-leg alignment films, with
pre-operative assessment of osteoarthritis severity according to Kellgren and Lawrence grading (Figure 2). Post-operative
radiographic assessment included component and limb alignment, signs of loosening, heterotopic ossification and any
adverse features according to the Knee Society radiographic criteria [11,12], to define any possible risk factors that may lead
to failure. Data were analysed with SAS (SAS Analytics, NC, USA) using paired t-tests against pre-operative baseline measure-
ments to detect functional and clinical outcome, satisfaction and safety profile. Outcome measures were compared across
follow-up visits using the Wilcoxon signed-rank test and additionally sub-categorised across age and gender using the Wil-
coxon rank-sum test at each review. P-values were adjusted for multiple comparisons using the false discovery rate (FDR)
method, with values less than 0.05 considered significant.

3. Results

Of 156 patients who underwent TKR within the study, 137 (87.8%) patients were retained at two years’ follow up. None of
the TKRs had been revised and two patients had died of unrelated causes.

3.1. Functional clinical outcomes and patient satisfaction

3.1.1. Range of motion


Pre-operative range of motion (116 ± 14°) was largely regained by six months (113 ± 14.6°).

3.1.2. KSS
Overall, mean improvement at 2 post-operative years was 34.8 (from 48.6 to 83.4) (Table 1, Figure 3). Pre-operatively,
only 1.3% and 14.1% of patients reported excellent clinical and functional scores respectively. This improved to 20.4% and
34.2% by six post-operative weeks. Excellent clinical and functional scores were seen in the majority of patients by six
months, and in 81.8% and 88.3% of patients at two years, respectively (Tables 2 and 3). This was mirrored by mean KSS func-
tional scores, which improved from 55.6 (SD ±18.5) pre-operatively, to 65.5 (±22.0) at six weeks and 90.2 (±18.1) at two
years (Table 1, Figure 4). There was a highly significant improvement (p < 0.0001) in both median clinical and functional
scores between each timepoint up to one year post-operatively. When comparing KSS by age or gender at each timepoint,
there were no significant differences in outcome, except that male functional scores improved significantly more than
females at six weeks and six months post-operatively (p = 0.0225 and 0.0002 respectively).

3.1.3. KOOS
All mean sub-scores improved significantly during the follow-up period with total KOOS improving from a mean of
35.5 (±13.0) to 86.5 (±13.7) at two years post-operatively (Table 4, Figure 5). Highly significant (p < 0.001) incremental

Figure 2. Radiographic analysis. Anteroposterior, lateral and long leg alignment views of a patient’s left knee before and after implantation with the Physica
KR total knee replacement.

64
A.R. Harvey, I.W. Barlow, C. Carulli et al. The Knee 39 (2022) 62–70

Table 1
Summary of patient retention (n (%)), and clinical and functional scores through the first two post-operative years (mean (±SD)). VAS Satisfaction and FJS were
measured from 6 weeks and 1 year post-operatively, respectively.

Score Patients KSS Clinical KSS Functional OKS FJS VAS Satisfaction
Pre-operative (T0) 156 (100%) 48.6 (14.6) 55.6 (18.5) 20.2 (6.8) – –
6 weeks (T1) 153 (98.1%) 65.9 (16.3) 65.5 (22.0) 30.5 (7.8) – 73.8 (19.9)
6 months (T2) 149 (95.5%) 77.8 (14.6) 85.2 (19.0) 39.5 (6.9) – 80.9 (19.6)
1 year (T3) 151 (96.8%) 82.3 (13.5) 90.0 (17.1) 42.3 (6.0) 64.4 (27.2) 87.1 (14.7)
2 years (T4) 137 (87.8%) 83.4 (11.7) 90.2 (18.1) 44.1 (5.1) 75.7 (26.5) 88.4 (16.6)

Figure 3. Mean Clinical Knee Society Score (KSS, FU = Follow up).

Table 2
KSS Clinical scores through first two post-operative years (n (%)).

Visit Poor Fair Good Excellent


Pre-operative (T0) 122 (78.2%) 28 (17.9%) 4 (2.6%) 2 (1.3%)
6 weeks (T1) 53 (34.9%) 24 (15.8%) 44 (28.9%) 31 (20.4%)
6 months (T2) 19 (12.8%) 7 (4.7%) 46 (30.9%) 77 (51.7%)
1 year (T3) 10 (6.7%) 3 (2%) 30 (20.1%) 106 (71.1%)
2 years (T4) 8 (5.8%) 3 (2.2%) 14 (10.2%) 112 (81.8%)

Table 3
KSS Functional scores through first two post-operative years.

Visit Poor Fair Good Excellent


Pre-operative (T0) 88 (56.4%) 28 (17.9%) 18 (11.5%) 22 (14.1%)
6 weeks (T1) 51 (33.6%) 20 (13.2%) 29 (19.1%) 52 (34.2%)
6 months (T2) 12 (8.1%) 4 (2.7%) 14 (9.4%) 119 (79.9%)
1 year (T3) 8 (5.4%) 2 (1.3%) 9 (6%) 130 (87.2%)
2 years (T4) 6 (4.4%) 2 (1.5%) 8 (5.8%) 121 (88.3%)

improvements of each sub-score were noted at every post-operative timepoint, except for sports between six months and one
year post-operatively which still reached significance (p = 0.0457). When comparing KOOS by age or gender at each time
point, there were no significant differences in outcome at any time point, except that patients over 65 had a significantly
higher stiffness score at one year (p = 0.0118). The pain and sports sub-scores improved particularly rapidly during the early
post-operative periods, with sustained improvements beyond this (Figure 5, Table 4).

3.1.4. OKS
Poor scores were noted in 78% of the patients pre-operatively, but in fewer than 30% by six weeks post-operatively and
just 1.5% of patients at two years. In contrast, good or excellent pre-operative scores were seen in 2.6% of patients, but was
achieved by 36.2% by the sixth post-operative week and 95.5% by two years (Table 5). OKS improved rapidly for the first six
65
A.R. Harvey, I.W. Barlow, C. Carulli et al. The Knee 39 (2022) 62–70

Figure 4. Mean Functional Knee Society Score (KSS).

Table 4
KOOS sub-scores and total scores by timepoint (mean (±SD)).

Visit Symptoms Pain ADLs Sports QoL Total


Pre-operative (T0) 44.9 (18.0) 40.7 (13.4) 46.0 (16.8) 17.9 (17.5) 22.5 (14.8) 35.5 (13.0)
6 weeks (T1) 63.6 (15.9) 67.0 (16.1) 75.4 (14.9) 36.3 (27.0) 52.0 (18.9) 62.0 (15.4)
6 months (T2) 79.0 (14.9) 82.6 (16.3) 84.9 (14.2) 63.1 (24.6) 68.9 (22.2) 76.7 (15.6)
1 year (T3) 83.6 (14.9) 88.5 (14.8) 89.0 (13.8) 69.2 (23.8) 77.5 (20.9) 82.2 (15.3)
2 years (T4) 88.2 (13.6) 92.5 (12.1) 92.8 (11.6) 74.3 (22.2) 82.1 (20.1) 86.5 (13.7)

Figure 5. Knee injury and Osteoarthritis Outcome Score (KOOS).

months and then with a shallower trajectory to 44.1 (±5.1) at two years (Table 1, Figure 6). Improvements at each time-point
were all highly statistically significant (p < 0.0001). When comparing by age or gender, there were no statistically significant
differences at any time-point.

66
A.R. Harvey, I.W. Barlow, C. Carulli et al. The Knee 39 (2022) 62–70

Table 5
OKS at time-points up to two years post-operatively.

Visit Poor Fair Good Excellent


Preoperative (T0) 122 (78.2%) 30 (19.2%) 4 (2.6%) 0
6 weeks (T1) 45 (29.6%) 52 (34.2%) 42 (27.6%) 13 (8.6%)
6 months (T2) 7 (4.8%) 18 (12.3%) 48 (32.9%) 73 (50%)
1 year (T3) 3 (2%) 6 (4.1%) 37 (25%) 102 (68.9%)
2 years (T4) 2 (1.5%) 4 (3%) 18 (13.3%) 111 (82.2%)

Figure 6. Oxford Knee Score (OKS).

3.1.5. VAS satisfaction


Scores improved significantly at all time points beyond six weeks (Table 1), although comparison by age and gender
revealed no significant differences between these parameters at any post-operative time-point.

3.1.6. FJS-12
FJS was measured from one year post-operatively, with mean score of 64.4 at one year and 75.7 at two years. The
improvement in this period was highly statistically significant (p < 0.001) and there were no significant effects of age or gen-
der on the score.

3.2. Radiographic outcomes

Post-operative component and limb alignment were maintained throughout the study period. 1 mm radiolucent lines
were present in two patients (1.2%) on immediate post-operative films (tibia, zone 4, femur zone 1). By two years post-
operatively there were two femoral lucencies over 2 mm wide (both in zone 1) and two around the tibial component (zone
1 and zone 4).
Zone 1 and 4 of both the tibial and femoral components demonstrated lucent lines of up to 1 mm at two years – seven
femoral and 13 tibial lucencies were noted in zone 1 and two femoral and five tibial lucencies were noted in zone 4. A further
two 1 mm lines were seen in femoral zone two, and in the tibia there was one in zone 5, three in zone 6 and one in zone 8.
The majority of these lucencies were noted within six months post-operatively and appeared non-progressive up to the cur-
rent study end-point. No patellar radiolucent lines were demonstrated at any time-point. Heterotopic ossification was noted
in five knees during the study period, but had not progressed beyond Brooker grade II in any patient at two years.

3.3. Complications

There were complications in eight patients (5%) (Table 6). No cases of revision, loosening, implant migration or serious
adverse events were reported.
67
A.R. Harvey, I.W. Barlow, C. Carulli et al. The Knee 39 (2022) 62–70

Table 6
Complications (both intra-operative complications were identified and resolved during
the index procedures).

Complications
Intra-operative
Tibial plateau fracture (minimally-displaced) 1 (0.6%)
Incorrect tibial prosthesis rotation (removed and re-implanted) 1 (0.6%)
Post-operative
Deep vein thrombosis 3 (1.9%)
Post-operative anaemia requiring transfusion 2 (1.3%)
Haematoma (resolved conservatively) 1 (0.6%)
Total 8 (5.0%)

4. Discussion

Although TKR has had success in abolishing pain and correcting deformity from arthritis for many years, a significant
minority of patients remain unsatisfied with their functional outcome and ongoing symptoms. In order to address this, an
appreciation of the native knee’s kinematics have allowed the design of novel implants that reproduce natural movements
throughout the range of motion. Early clinical and radiographic outcomes of this kinematic-retaining knee prosthesis are
promising, with improvements in clinical parameters similar to, or exceeding those published in other contemporary TKR
designs. Varying design philosophies have recently been introduced to try to address the deficiencies in functional outcome.

4.1. Comparison with other contemporary TKR designs

4.1.1. KOOS
Patients implanted with the cementless Triathlon Tritanium TKR achieved KOOS improvements from 33.1 pre-operatively
to 84.1 at a mean follow up of 5.5 years, comparable with the improvement seen in the present study [13]. A retrospective
study of the Persona Knee System reported three-year post-operative mean KOOS improvements of 39 for symptoms, 40 for
pain and 29 for daily living [14]. The current study compares favourably at only two years post-operatively, with improve-
ments of 43.3, 51.8 and 46.8, respectively. Another study assessing the outcomes of the Persona system at two years reported
KOOS of 55.0 for sports and 78.2 for quality of life, compared to 74.3 and 82.1 respectively in the current study [15]. Scores
reported for the Unity system at one year, demonstrated similar, but perhaps not as marked, improvements to those seen for
each subscore in the current study [16].

4.1.2. OKS
OKS for patients in the present study improved by an average of 19.3 points over the first six post-operative months and a
further to 4.6 points (to 44.1) at two years. Two studies reporting the outcomes of the Attune TKR, demonstrated mean OKS
improvements of 12.1 and 15.7 at six months [17,18], improving by just another 0.5 points at two years. A two year follow up
study of the Persona demonstrated improvements of 18.9 at one year although in contrast to the Physica KR, little improve-
ment was noted beyond this [19]. A study of the Unity knee demonstrated a mean OKS of 45.9 at two years, although base-
line pre-operative scores were not published [20].

4.1.3. KSS
The mean KSS clinical and functional scores in the current study had improved by 34.8 and 34.6 points respectively, at
two years post-operatively. In a study of the Attune system, improvements of 49.9 and 18.4 points respectively, were noted
[18]. Two further studies of the Attune system reported KSS functional score improvements of 37.2 and 37.3 at two years
[21,22] A study of the Journey II Bicondylar TKR reported clinical and functional KSS of 93.7 and 75.4 at six months, and
96.2 and 81.5 at two years. Although the clinical scores for the Journey II are slightly higher than the present study, the func-
tional scores are lower. Additionally, this study was retrospective and no baseline pre-operative data or comparisons are
available [23]. Another study of the Journey II reported improvements of clinical and functional KSS respectively from 26
and 21 to 91 and 88 at about two years follow up [24]. Again, this study was retrospective with undefined study entry points.
Furthermore, even the second iteration of the Journey knee has a higher revision rate in clinical use (2.96% at three years)
than benchmark figures within joint registry data [25]. A retrospective study of the Persona TKR reported KSS clinical
improvements from 45 to 94 and functional improvements from 46 to 92 at three post-operative years [14], with another
study demonstrating mean KSS improvements of 35.3 (57.3–92.6) for clinical and 26.3 (49.1–75.4) for functional scores
at a mean 3.9 years’ follow-up [26]. These results compare similarly to the present study’s findings. KSS was also measured
for the Unity TKR [20]. Although the mean clinical and functional KSS at two years’ post-implantation were slightly superior
(87.1 and 96.4, respectively), no pre-operative baseline scores are reported.
68
A.R. Harvey, I.W. Barlow, C. Carulli et al. The Knee 39 (2022) 62–70

4.1.4. FJS-12
FJS-12 for patients in the current study was 75.7 at two years post-operatively. This compares to other contemporary
knee replacement designs. The Attune achieved FJS-12 of 67.6 [27], while the Vanguard CR and SAIPH medially stabilised
knees achieved 63.8 and 79.9 respectively at one year [28]. Scores of 66.2 and 69.2 have been published at two years for
the Triathlon knee implanted in mechanical and clinical alignment respectively [29].

4.1.5. Radiographic measures


Radiographic outcomes were encouraging, with only a small minority demonstrating lucencies in any zone. Concerns
have been raised with respect to the shorter keels in modern knee replacement designs, potentially predisposing to progres-
sive loosening, but this has not been borne out in practice with other prostheses [26]. Studies of other modern, high-
functioning knee implants frequently show a minority with non-progressive asymptomatic lucencies [15,20,26]. It remains
to be seen if the small number of lucencies seen in the present study go on to progress beyond the current two year follow
up, although we have seen no evidence of the early failure at the implant-cement interface experienced by another new
implant [30–32]. We observed no significant malalignment or heterotopic ossification in the current study.

Conclusion

Limitations of this study include a relatively small study sub-group, no direct control comparison and short initial follow-
up period. However, further periodic follow-up of this cohort is planned. Despite these limitations, this study demonstrates
prompt functional recovery with substantial pain relief even in high-demand patients, when implanted with this TKR. It is
thought that these promising early results are a consequence of the implant exhibiting physiological kinematics. Confirma-
tory fluoroscopic kinematic studies of a sub-cohort of patients are being performed separately.

Funding

This research received funding from Lima Corporate Spa, Italy.

Authors’ contributions

ARH, IWB and MI designed and coordinated the study. All the authors participated in patient recruitment, the surgical
procedures and post-operative care and follow-up. JOS and ARH drafted the manuscript. All authors read, amended and
approved the final manuscript.

Ethical approval

Approval was obtained from the Regional Ethics Committee of the principal centres. The trial was registered through
ClinicalTrials.gov (NCT02118272). For UK sites: IRAS project ID is 137766/REC reference is 13/EE/0438. For Italian site: EC
reference is SPE_14.080.
The implant holds a European conformance CE Mark and has been registered with ODEP (Orthopaedic Data Evaluation
Panel) and the Beyond Compliance Advisory Group for ongoing clinical assurance.

Informed consent

All patients underwent appropriate informed consent for inclusion in this study and for measurement, storage and anal-
ysis of their data.

Declaration of Competing Interest

The authors declare that they have no known competing financial interests or personal relationships that could have
appeared to influence the work reported in this paper.

Acknowledgements

The authors thank the research teams at each institution for collecting and managing the patient data and for the patients
themselves for their time and effort contributing to the data used in this study.

References

[1] Evans JT, Walker RW, Evans JP, Blom AW, Sayers A, Whitehouse MR. How long does a knee replacement last? A systematic review and meta-analysis of
case series and national registry reports with more than 15 years of follow-up. Lancet 2019;393:655–63.

69
A.R. Harvey, I.W. Barlow, C. Carulli et al. The Knee 39 (2022) 62–70

[2] Baker PN, van der Meulen JH, Lewsey J, Gregg PJ. The role of pain and function in determining patient satisfaction after total knee replacement. Data
from the National Joint Registry for England and Wales. J Bone Joint Surg Br 2007;89(7):893–900.
[3] Gandhi R, Davey JR, Mahomed NN. Predicting patient dissatisfaction following joint replacement surgery. J Rheumatol 2008;35(12):2415–8.
[4] Kim TK, Chang CB, Kang YG, Kim SJ, Seong SC. Causes and predictors of patient’s dissatisfaction after uncomplicated total knee arthroplasty. J
Arthroplasty 2009;24(2):263–71.
[5] Scott CE, Howie CR, MacDonald D, Biant LC. Predicting dissatisfaction following total knee replacement: a prospective study of 1217 patients. J Bone
Joint Surg Br 2010;92(9):1253–8.
[6] Iwaki H, Pinskerova V, Freeman MA. Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver
knee. J Bone Joint Surg Br 2000;82(8):1189–95.
[7] Pinskerova V, Johal P, Nakagawa S, Sosna A, Williams A, Gedroyc W, et al. Does the femur roll-back with flexion? J Bone Joint Surg Br 2004;86-B
(6):925–31.
[8] Nägerl H, Frosch KH, Wachowski MM, Dumont C, Abicht C, Adam P, et al. A novel total knee replacement by rolling articulating surfaces. In vivo
functional measurements and tests. Acta Bioeng Biomech 2008;10(1):55–60.
[9] Victor J, Bellemans J. Physiologic kinematics as a concept for better flexion in TKA. Clin Orthop Relat Res 2006;452:53–8.
[10] Bullens PH, van Loon CJ, de Waal Malefijt MC, Laan RF, Veth RP. Patient satisfaction after total knee arthroplasty: a comparison between subjective and
objective outcome assessments. J Arthroplasty 2001;16(6):740–7.
[11] Ewald FC. The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 1989;248:9–12.
[12] Sarmah SS, Patel S, Hossain FS, Haddad FS. The radiological assessment of total and unicompartmental knee replacements. J Bone Joint Surg Br 2012;94
(10):1321–9.
[13] Restrepo S, Smith EB, Hozack WJ. Excellent mid-term follow-up for a new 3D-printed cementless total knee arthroplasty. Bone Joint J 2021;103-B(6
Supple A):32–7.
[14] Bernard de Villeneuve F, Jacquet C, Puech S, Parratte S, Ollivier M, Argenson JN. Minimum Five Years Follow-Up of Total Knee Arthroplasty Using
Morphometric Implants in Patients with Osteoarthritis. J Arthroplasty 2021;36(7):2502–9.
[15] Galea VP, Botros MA, Madanat R, Nielsen CS, Bragdon C. Promising early outcomes of a novel anatomic knee system. Knee Surg Sports Traumatol
Arthrosc 2019;27(4):1067–74.
[16] Pourmoghaddam A, Dettmer M, Malanka S, Kreuzer S. Comparison of Functional Outcomes of Total Knee Arthroplasty Using Two Different Single
Radius Implants. Reconstruct Rev 2016;6(1):43–8.
[17] Carey BW, Harty J. A comparison of clinical- and patient-reported outcomes of the cemented ATTUNE and PFC sigma fixed bearing cruciate sacrificing
knee systems in patients who underwent total knee replacement with both prostheses in opposite knees. J Orthop Surg Res 2018;13(1):54.
[18] Chua JL, Goh GS, Liow MHL, Tay DK, Lo NN, Yeo SJ. Modern TKA implants are equivalent to traditional TKA implants in functional and patellofemoral
joint-related outcomes. Knee Surg Sports Traumatol Arthrosc 2019;27(4):1116–23.
[19] Mathijssen NMC, Verburg H, London NJ, Landsiedl M, Dominkus M. Patient reported outcomes and implant survivorship after Total knee arthroplasty
with the persona knee implant system: two year follow up. BMC Musculoskelet Disord 2019;20(1):97.
[20] Paszicsnyek T. Early Experience with a Modern Generation Knee System: Average 2 Years’ Follow-up. Reconstruct Rev 2015;5(4):23–8.
[21] Ranawat CS, White PB, West S, Ranawat AS. Clinical and Radiographic Results of Attune and PFC Sigma Knee Designs at 2-Year Follow-Up: A
Prospective Matched-Pair Analysis. J Arthroplasty 2017;32(2):431–6.
[22] Song SJ, Park CH, Liang H, Kang SG, Park JJ, Bae DK. Comparison of Clinical Results and Injury Risk of Posterior Tibial Cortex Between Attune and Press
Fit Condylar Sigma Knee Systems. J Arthroplasty 2018;33(2):391–7.
[23] Harris AI, Luo TD, Lang JE, Kopjar B. Short-term safety and effectiveness of a second-generation motion-guided total knee system. Arthroplast Today
2018;4(2):240–3.
[24] Hommel H, Wilke K. Good Early Results Obtained with a Guided-Motion Implant for Total Knee Arthroplasty: A Consecutive Case Series. Open Orthop J
2017;24(11):51–6.
[25] No authors listed. National Joint Registry: National Joint Registry for England and Wales; 17th Annual Report 2020.
[26] Yang JaeWon, Heckmann ND, Nahhas CR, Salzano MB, Ruzich GP, Jacobs JJ, et al. Early outcomes of a modern cemented total knee arthroplasty: is tibial
loosening a concern? Bone Joint J 2021;103-B(6 Supple A):51–8.
[27] Behrend H, Zdravkovic V, Bösch M, Hochreiter B. No difference in joint awareness after TKA: a matched-pair analysis of a classic implant and its
evolutional design. Knee Surg Sports Traumatol Arthrosc 2019;27(7):2124–9.
[28] French SR, Munir S, Brighton R. A Single Surgeon Series Comparing the Outcomes of a Cruciate Retaining and Medially Stabilized Total Knee
Arthroplasty Using Kinematic Alignment Principles. J Arthroplasty 2020;35(2):422–8.
[29] Young SW, Sullivan NPT, Walker ML, Holland S, Bayan A, Farrington B. No Difference in 5-year Clinical or Radiographic Outcomes Between Kinematic
and Mechanical Alignment in TKA: A Randomized Controlled Trial. Clin Orthop Relat Res 2020;478(6):1271–9.
[30] Bonutti P, Khlopas A, Chughtai M, Cole C, Gwam C, Harwin S, et al. Unusually High Rate of Early Failure of Tibial Component in ATTUNE Total Knee
Arthroplasty System at Implant-Cement Interface. J Knee Surg 2017;30(05):435–9.
[31] Hazelwood KJ, O’Rourke M, Stamos VP, McMillan RD, Beigler D, Robb 3rd WJ. Case series report: Early cement-implant interface fixation failure in total
knee replacement. Knee 2015;22(5):424–8.
[32] Staats K, Wannmacher T, Weihs V, Koller U, Kubista B, Windhager R. Modern cemented total knee arthroplasty design shows a higher incidence of
radiolucent lines compared to its predecessor. Knee Surg Sports Traumatol Arthrosc 2019;27(4):1148–55.

70

You might also like