8030nts-gps Din v0601 en
8030nts-gps Din v0601 en
8030nts-gps Din v0601 en
_____________________________________________________________
Technical Manual
Model 8030NTS/GPS
For DIN Rail Installation
(DIN EN 60715 TH35)
ENGLISH
Version: 06.01 - 16.06.2021
_____________________________________________________________
THE TERM SET DEFINES THE FIXED RELATIONSHIP BETWEEN THE IMAGE VERSION
AND THE ASSOCIATED H8 FIRMWARE VERSION.
THE FIRST TWO DIGITS OF THE TECHNICAL DESCRIPTION VERSION NUMBER, THE
SET VERSION AND THE IMAGE VERSION MUST BE THE SAME! THEY DESIGNATE THE
SHARED FUNCTIONAL IDENTITY BETWEEN DEVICE, SOFTWARE AND TECHNICAL DE-
SCRIPTION.
THE VERSION NUMBER OF THE IMAGE AND THE H8 SOFTWARE CAN BE READ IN THE
WEBGUI OF TIME SERVER 8030NTS/GPS (SEE CHAPTER 7.3.6.1 DEVICE INFOR-
MATION AND CHAPTER 7.3.6.2 HARDWARE INFORMATION).
THE TWO DIGITS AFTER THE DOT IN THE VERSION NUMBER DESIGNATES CORREC-
TIONS TO THE FIRMWARE AND/OR DESCRIPTION WHICH HAVE NO EFFECT ON FUNC-
TIONALITY.
Operational Reliability
Disregard may cause damages to persons or material.
Functionality
Disregard may impact function of system/device.
Information
Notes and Information.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 3 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
SERVICE RELIABILITY
Safety regulations
The safety regulations and observance of the technical data serve to en-
sure trouble-free operation of the device and protection of persons and
material. It is therefore of utmost importance to observe and compliance
with these regulations.
If these are not complied with, then no claims may be made under the
terms of the warranty. No liability will be assumed for any ensuing dam-
age.
CE-Conformity
This device fulfils the requirements of the EU directive 2014/30/EU
"Electromagnetic Compatibility" and 2014/35/EU "Low Voltage Equipment".
Therefore the device bears the CE identification marking
(CE = Communautés Européennes = European communities)
The CE indicates to the controlling bodies that the product complies with the requirements of
the EU directive - especially with regard to protection of health and safety for the operator and
the user - and may be released for sale within the common markets.
4 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
TABLE OF CONTENTS
Contents Page
1 GPS - NTP Time Server 8030NTS/GPS ........................................................................ 9
2 System Structure ........................................................................................................ 12
2.1 Housing ................................................................................................................... 12
2.2 Power Supply .......................................................................................................... 12
2.3 Functional Overview of the Front Panel Elements ................................................... 13
2.3.1 Reset-(Default) Button ....................................................................................................... 13
2.3.2 Status LEDs (TS/Error/Operation) ..................................................................................... 13
2.3.3 USB-Port ............................................................................................................................ 13
2.3.4 LAN Interface ETH0/ETH1 ................................................................................................. 14
2.3.4.1 MAC-Address for ETH0/ETH1 .................................................................................................... 14
2.3.5 Sync Status Optical Coupler .............................................................................................. 15
2.3.6 Sync Status LEDs .............................................................................................................. 15
2.3.7 GPS Antenna Input ............................................................................................................ 15
3 Function Principle....................................................................................................... 16
3.1 Block Diagram ......................................................................................................... 16
3.2 Function 8030NTS (WebGUI: Device) ..................................................................... 17
3.3 Function 8024GPS (WebGUI: Sync Source) ........................................................... 17
4 System Behaviour....................................................................................................... 18
4.1 Boot Phase .............................................................................................................. 18
4.2 NTP Adjustment Process (NTP/Stratum/Accuracy) ................................................. 18
4.3 Reset-(Default) Button ............................................................................................. 18
4.4 Firmware Update ..................................................................................................... 19
4.4.1 Firmware Update 8030NTS (WebGUI: Device) ................................................................. 19
4.4.2 Firmware Update 8024GPS (WebGUI: Sync Source) ....................................................... 20
4.5 Activation of Functions (Activation Key) ................................................................... 21
5 Installation ................................................................................................................... 22
5.1 Installation/Dismounting of the DIN Rail Housing ..................................................... 22
5.1.1 Mounting ............................................................................................................................ 22
5.1.2 Dismounting ....................................................................................................................... 22
5.2 Protective Earth Conductor (Grounding) .................................................................. 23
5.3 Power Connection ................................................................................................... 23
5.3.1 AC Power Supply ............................................................................................................... 23
5.3.1.1 Safety and Warning Instructions ................................................................................................. 23
5.3.1.2 Connection to various Power Networks ...................................................................................... 24
5.3.1.3 Power Cable Connection ............................................................................................................ 24
5.3.1.4 Voltage Input / Fuse Protection ................................................................................................... 25
5.3.1.5 Power Supply Specifications....................................................................................................... 25
5.3.1.6 Power LED.................................................................................................................................. 25
5.3.2 DC Power Supply ............................................................................................................... 25
5.3.2.1 Power Supply Unit Specifications ............................................................................................... 26
5.3.2.2 Fuse Protection........................................................................................................................... 26
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 5 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
TABLE OF CONTENTS
6 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
TABLE OF CONTENTS
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 7 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
TABLE OF CONTENTS
8 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
GPS - NTP TIME SERVER 8030NTS/GPS
The Time Server is integrated into a compact DIN Rail housing and is characterized by its
easy and simple operation, although it offers a broad range of functions. Some of the prac-
tice-oriented functionalities are:
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 9 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
GPS - NTP TIME SERVER 8030NTS/GPS
A superior security is guaranteed via available coding procedures such as symmetric keys,
autokey and access restrictions and deactivation of non-used protocols.
Diffferent Managemenet and Monitoring Functions are availabe as options (e.g. SNMP,
SNMP-Traps, E-mail notification, Syslog-messages including MIB II and private Enterprise
MIB).
Software supplied:
• hmc (hopf Management Console) Software
10 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
GPS - NTP TIME SERVER 8030NTS/GPS
Ethernet Interface
• Auto negotiate
• 10 Mbps half-/full duplex
• 100 Mbps half-/full duplex
• 1 Gbps full duplex
Time Protocols
• RFC-5905 NTPv4 Server
o NTP Broadcast Mode
o NTP Multicast Mode
o NTP Client for additional NTP Servers (redundancy)
o SNTP Server
o NTP Symmetric Key Encryption
o NTP Autokey Encryption
o NTP Access Restrictions
• SINEC H1 time datagram (Activation Key necessary)
• RFC-867 DAYTIME Server
• RFC-868 TIME Server
• Precision Time Protocol (PTP) according to IEEE Std 1588™-2008 (Activation Key
necessary)
o IEEE Standard Profile for Use of IEEE 1588™ Precision Time Protocol
in Power System Applications (Power Profile) according
to IEEE Std C37.238™-2011
Configuration Channel
• HTTP/HTTPS WebGUI (browser-based)
• Telnet
• SSH
• External LAN configuration tool (hmc - Network-Configuration-Assistant)
• hmc Remote connection
Additionally Freatures
• Firmware Update via TCP/IP
• Fail-safe
• Watchdog circuit
• Customized security banner
• NTP local time support
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 11 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
SYSTEM STRUCTURE
2 System Structure
Views of the Timer Server 8030NTS/GPS with AC and DC power supply.
2.1 Housing
The Time Server 8030NTS/GPS is built into a closed aluminium profile housing for horizontal
DIN Rail mounting according to DIN EN 60715 TH35.
12 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
SYSTEM STRUCTURE
2.3.3 USB-Port
On specific problems the USB connection can be used for a system recovery
after consulting the hopf Support.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 13 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
SYSTEM STRUCTURE
The MAC address is uniquely assigned for each LAN interface by the company hopf El-
ektronik GmbH.
14 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
SYSTEM STRUCTURE
The Status LEDs on the front panel signal the current (synchronization) status of the Sync
Source (here Module 8024GPS). The meanings of the LEDs are as follows:
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 15 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
FUNCTION PRINCIPLE
3 Function Principle
This chapter describes the function principle of the Time Server 8030NTS/GPS and the inter-
nal relations between the different functional groups.
16 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
FUNCTION PRINCIPLE
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 17 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
SYSTEM BEHAVIOUR
4 System Behaviour
This chapter describes the behaviour of the system in special operational phases and condi-
tions.
Duration Function
< 1 sec. No action
1 - 9 sec. After releasing a systemwide hardware reset is triggered
>= 10 sec. After releasing a FACTORY DEFAULT followd by a REBOOT is
triggered after approx. 10 seconds
18 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
SYSTEM BEHAVIOUR
The progam releases assigned to a SET version may be taken from the
release notes of the software SETs of the Time Sever 8030NTS/GPS.
For selection of the correct update set the identifier 8030NTS has to be
observed obligatory.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 19 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
SYSTEM BEHAVIOUR
Image Update
10. Log in as Master in WebGUI of the board.
11. Select in Device tab the menu item Image Update.
12. Select the file with the file .img via the selection window.
13. The selected file is shown in the selection window.
14. The update process is started with the button Upload now.
15. In WebGUI the successful file transfer and writing to the Module is indicated.
16. In WebGUI the successful update is indicated after 2-3 minutes with the request to
release a reboot of the board.
17. After activation and successful reboot of the board the image update process is fin-
ished.
H8 Update
1. Log in as Master in WebGUI of the board.
2. Select in the GPS SYNC SOURCE tab the menu item H8 Firmware Update.
3. Select the file with the file extension .mot for Module 8024 via the selection window.
4. The selected file is shown in the selection window.
5. The update process is started with the button Upload now.
6. In WebGUI the successful file transfer to the Module is indicated.
7. Now the update of the board automatically starts after a few seconds.
8. After successful update the board automatically reboots.
9. After approx. 2 minutes the H8 update process is finished and the board is again ac-
cessible via WebGUI.
20 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
SYSTEM BEHAVIOUR
The settins for activation keys (e.g. an entered activation key) are neither
modified nor influenced by the function FACTORY DEFAULTS.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 21 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
INSTALLATION
5 Installation
The installation of the Time Server 8030NTS/GPS is described below.
Dimensions
The dimensions of the housing can be found in Chapter 11.5 Dimensions – DIN Rail Hous-
ing.
• Time Server 8030NTS/GPS – Housing: TYPE 2
5.1.1 Mounting
Place the module’s rail guide bar against the lower edge of the rail, push the module
upwards, and clip to the back.
5.1.2 Dismounting
Push the module upwards and then tip forward to remove from the rail.
22 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
INSTALLATION
The power cable is connected via a 3pole pluggable screw terminal with housing.
N
L
Connecting the incorrect voltage can damage the Time Server 8030NTS/GPS.
The Time Server 8030NTS/GPS is a built-in device. Installation and commissioning may only
be carried out by suitable specialist personnel. In doing so the respective country-specific reg-
ulations (e.g. VDE, DIN) must be observed.
In particular, before commissioning please ensure that
• The power connection has been installed correctly and there is guaranteed protection
against electric shock!
• The ground wire is connected!
• All power cables are correctly fused and sized!
• All output lines are sized in accordance with the max. output current of the device or
are specially fused!
• Sufficient convection is guaranteed!
The device contains components carrying life-threatening voltage and a high amount of stored
energy!
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 23 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
INSTALLATION
The connector must always be mounted using the housing and strain re-
lief fitting provided.
24 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
INSTALLATION
If the internal fuse trips it is highly likely that the device is faulty. In this
case the equipment should be checked at the factory!
Make sure that the external voltage source is switched off. When connect-
ing the power supply, ensure that the polarity and ground connection are
correct!
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 25 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
INSTALLATION
Grounding:
The negative pole (-Vin) and the ground (PE) are connected together as
standard on the system side.
If the internal fuse (device fuse) blows, it is most probable that the device
is defective. In this case the device needs to be checked in the facatory!
GPS Antenna
BNC Connector
GPS Antenna input
26 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
INSTALLATION
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 27 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
COMMISSIONING
6 Commissioning
This chapter describes commissioning of the Time Server 8030NTS/GPS.
In order to obtain correct time outputs in local time or standard time, the
difference between UTC and summer / winter time changeover must be
parameterized when starting up for the first time and after each factory de-
fault.
28 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
COMMISSIONING
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 29 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
COMMISSIONING
IP-address: 192.168.0.1
Network mask: 255.255.255.0
Gateway: not set
In case it is not known whether the Time Server 8030NTS/GPS with a Fac-
tory Default setting causes problems in the network, the basis network pa-
rameterization should be executed via a "Peer to Peer" network connec-
tion.
The network connection is made via a LAN cable and RJ45 plug (recommended cable type:
CAT5 or better).
30 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
COMMISSIONING
The base LAN parameters can be set via the hmc integrated Network Configuration Assis-
tant.
After a successful start of the hmc Network Configuration Assistant and completed search
of the hopf LAN devices, the configuration of the base LAN parameters can be done.
The factory set MAC address for the Time Server 8030NTS/GPS is stated
on a sticker laterally positioned on the exterior of the housing of the device.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 31 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
COMMISSIONING
For an extended configuration of the Time Server 8030NTS/GPS through a browser via
WebGUI the following base parameters are required:
IP Address (IPv4)
An IP address is a 32 bit value divided into four 8 bit numbers. The standard presenta-
tion is 4 decimal numbers (in the range 0...255) separated from each other by dots
(dotted quad notation).
Example: 192.002.001.123
The IP address consists of a leading network ID followed by the host ID. Four common
network classes were defined in order to cover different requirements. Depending on
the network class, the last one, two or three bytes define the host while the rest define
the network (network ID) in each case.
In the following text the "x" stands for the host part of the IP address.
Class A Networks
IP addresses 001.xxx.xxx.xxx to 127.xxx.xxx.xxx
There is a maximum of 127 different networks in this class. This allows the possibility to
connect a very high number of devices (max. 16.777.216)
Example: 100.000.000.001, (Network 100, Host 000.000.001)
Class B Networks
IP addresses 128.000.xxx.xxx to 191.255.xxx.xxx
Each of these networks can consist of up to 65534 devices.
Example: 172.001.003.002 (Network 172.001, Host 003.002)
32 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
COMMISSIONING
Class C Networks
IP addresses 192.000.000.xx to 223.255.255.xxx
These network addresses are the most commonly used. Up to 254 devices can be con-
nected.
Class D Networks
The addresses from 224.xxx.xxx.xxx - 239.xxx.xxx.xxx are used as multicast ad-
dresses.
Class E Networks
The addresses from 240.xxx.xxx.xxx - 254.xxx.xxx.xxx are designated as "Class E" and
are reserved.
Gateway Address
The gateway or router address is required in order to be able to communicate with other
network segments. The standard gateway must be set to the router address which con-
nects these segments. This address must be within the local network.
After entering the above mentioned LAN parameters, they needed to be transferred to the
Time Server 8030NTS/GPS via the Apply button. Afterwards the entry of the Device Pass-
word is requested:
The Time Server 8030NTS/GPS is supplied
with the default device password <device> on
delivery. After entry click on the OK button
to confirm.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 33 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
For the correct display and function of the WebGUI, JavaScript and Cookies
must be enabled in the browser.
7.1.1 Requirements
• Ready-for-operation hopf NTP Time Server 8030NTS/GPS
• PC with installed web browser (e.g. Internet Explorer) in the sub-network of Time
Server 8030NTS/GPS
34 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The WebGUI was developed for multi-user read access but not for multi-
user write access. It is the responsibility of the user to pay attention to this
issue.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 35 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The password should be changed after the first login for security reasons.
After successful login, depending on the access level (device or master user), changes can
be made to the configuration and saved.
Users logged in as "master" have all access rights to the Time Server 8030NTS/GPS.
36 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
User login is not required in order to navigate through the board configuration options.
All the links within the tabs on the left hand side lead to cor-
responding detailed display or setting options.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 37 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
After an entry with Apply is made, the configured field is marked with a star ' * '. This means
that a value has been entered or changed but not yet been stored in the flash memory.
If the data should only be tested it is sufficient to accept the changes with Apply.
For adopting changes and entering values only the respective buttons in
the WebGUI can be used.
38 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The new reading of the modified data from Module 8030NTS for the
WebGUI indication can take up to 30 seconds after data transfer to Mod-
ule 8024GPS.
However, this has no effect on the function of the appropriate set-
ting/value.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 39 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
As illustrated in the above image, an invalid value (e.g. text where a number should be entered,
IP address not within the range etc.) is identified by a red border when an attempt is made to
accept these settings. It should be noted here that this is only a semantic check and not to test
whether an entered IP address can be used on the own network or in the configuration! As
long as an error message is displayed it is not possible to save the configuration in the flash
memory.
The error check only verifies semantics and the validity of ranges. It is NOT
a logic or network check for entered data.
40 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 41 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Login
The login box is described in Chapter 7.2.1 LOGIN and LOGOUT as User.
System Overview
This table gives a direct overview of the Time Server’s 8030NTS/GPS current operating states.
WebGUI Description
Sync Source OK When active (RED) there is a Sync Souce
failure. For details please go to GPS SYNC
SOURCE tab - Module Errors.
Announcement leap second inactive When active (ORANGE) there is an an-
nouncement for a leap-second.
Announcement STD DST inactive When active (ORANGE) there is an an-
nouncement for a summer / winter time
change-over.
NTP is running The NTP process on Module 8030NTS is
running
NTP has stratum 1 Shows the appropriate stratum the NTP pro-
cess works with.
NTP Accuracy is High Shows the appropriate accuracy the NTP
process works with.
Announcements
The display fields LEAP SECOND and STD DST announce a corrosponding event to the
next hour (insertion of a leap-second or rather switchover of summer/winter time).
42 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
7.3.2.1 Host/Nameservice
Setting for the clear network detection.
7.3.2.1.1 Hostname
The standard setting for the Hostname is "hopf8030NTS". This name should also be adapted
to the respective network infrastructure.
If in doubt, simply leave the standard value in place or ask your network administrator.
For a correct operation a hostname is required. The field for the hostname
must not be left blank.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 43 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
44 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 45 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The use of customers MAC address needs to be activated by the function Use Custom Hard-
ware Address (MAC) with enable and subsequently save it with Apply and Save.
Afterwards the customers MAC address has to be entered in hexadecimal form with a colon
to separate as described in the below example, e.g. 00:03:c7:55:55:02
The MAC address assigned by hopf can be activated at any time by disa-
bling this function.
Finally, the Module 8030NTS has to be restarted via "Device" / "Reboot Device".
7.3.2.2.3 DHCP
If DHCP is to be used, activate this with enabled.
46 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
7.3.2.2.8 IPv6
The Time Server 8030NTS/GPS can also be operated in an IPv6 network.
To enable IPv6, Use IPv6 Settings must be set to enable.
IPv6 addresses are 128 bits long and they are recorded in eight 4-character hexadecimal
blocks. For example: 2001:0db8:0000:08d3:1319:8a2e:0370:7344
Leading zeroes in a 4-character hexadecimal block can be omitted. For the above example,
this results in the notation: 2001:db8:0:8d3:1319:8a2e:370:7344
In addition, once per IPv6 address a consecutive sequence of blocks containing all zeros may
be omitted. But this must be recorded with two consecutive colons. For the above example,
this gives the notation: 2001:db8::8d3:1319:8a2e:370:7344
Another example: 2001:0:0:0:1319:8a2e:0:7344 may be represented
as 2001::1319:8a2e:0:7344
or 2001:0:0:0:1319:8a2e::7344
7.3.2.2.9 DHCP-IPv6
If DHCP is to be used, this function is activated with enabled.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 47 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
VLAN ID one (1) and two (2) are reserved and are therefore not permitted!
48 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
This function is used for the distribution of load as well as to increase fail-safety in computer
networks.
If function Bonding has been activated, parameters for ETH0 and ETH1 cannot
be changed any more. The parameters are not displayed in the host setting
menu as long as Bonding will be deactivated.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 49 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
DHCP
Activation of DHCP of the "Bonding interface".
IPv4 address
Input of IPv4 address of the "Bonding interface".
If you do not know the IPv4 address, please contact your network administrator.
50 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
DHCP IPv6
Activation of IPv6 DHCP for the "Bonding interface"
IPv6 address
Input of the IPv6 address for the " Bonding interface".
If the IPv6 address is not known, it must be requested by the network administrator.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 51 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Bonding Policy
• Round-Robin:
In this case the network interfaces, starting with ETH0, are transmitting sequentially
whereby a distribution of load and a higher tolerance for errors are achieved. In that
mode the network interfaces must be connected to the same network switch.
• Active Backup:
Only one of two network interfaces is sending and receiving. If an error occurs, the
other network interface assumes responsibility for the process. The network inter-
faces do not have to be connected to the same network switch. From the outside the
MAC address of the association is only visible on one network interface to avoid a
mix-up. This mode supports tolerance for errors.
• Balance XOR:
Source and target are permanently assigned with one another via the MAC address
of the network interfaces ETH0 and ETH1. The network interfaces must be con-
nected to the same network switch. This mode supports distribution of load and tol-
erance for errors.
• Broadcast:
In this mode the computer sends its data via all available network interfaces which
enables the use of several network switches. This fact leads to a high tolerance for
errors, but this mode does not enable distribution of load.
The network switch on which the network interfaces ETH0 and ETH1 of
Time Server 8030NTS/GPS are connected also needs to be configured
correctly! A wrong configuration can lead to a loss of availability of Time
Server 8030NTS/GPS!
52 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Primary Device (only valid for active backup and TLB directive)
If this asset is configured and the network interface is active, the adjusted network interface is
going to be used. Only if the network interface is inactive, mode is changed to the second
network interface.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 53 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
PRP-suitable applications are known as DAN (Dual Attached Node) and are going to be con-
nected to the independent networks "LAN A" and "LAN B". The advantage of PRP is that cost-
efficient and common network switches can be used which do not have to support the PRP
standard. Applications which do not need to be redundantly available and which do not have
to support PRP can be connected without problems in one of the two LANs - they are then
called SAN (Single Attached Node). If it is necessary to redundantly connect non-PRP-sup-
porting applications to the PRP network, a so-called RedBox (Redundancy Box) can be used.
Time Server 8030NTS/GPS supports PRP as DAN and can therefore directly be integrated
into a PRP network without using a RedBox.
54 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
DHCP
Activation of DHCP for the "PRP interface".
IPv4 address
Input of the IPv4 address for the "PRP interface". If unknown the IPv4 address needs to be
obtained by the network administrator.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 55 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The MTU default setting with value 1466 should not be necessary by de-
fault.
An incorrect configuration can lead to a loss of the network connection
which refuses the Ethernet access to Time Server 8030NTS/GPS.
In that case the settings of Time Server 8030NTS/GPS need to be set to
"factory default"!
The network interface ETH0 of Time Server 8030NTS/GPS need to be connected to PRP
network "LAN A", network interface ETH1 need to be connected to PRP network "LAN B"!
If settings are done without profound knowledge of PRP, severe network prob-
lems can occur.
An incorrect configuration can lead to a loss of the network connection which
refuses the Ethernet access to Time Server 8030NTS/GPS.
In that case the settings of Time Server 8030NTS/GPS need to be set to "factory
default"!
If the functionality PRP was activated, parameters for ETH0 and ETH1 can no
longer be adapted. The parameters will not be displayed in the host settings
menu as long as PRP is going to be deactivated.
DHCP IPv6
Activation of IPv6 DHCP for the "PRP interface"
IPv6 address
Input of the IPv6 address for the " PRP interface".
If the IPv6 address is not known, it must be requested by the network administrator.
56 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The gateway / gateway host need to be in the local sub-network range of the module in order
to use the routes.
The image above shows every configured route of the base system routing table as well as
the user’s defined routes.
Select Use Route File to set whether the routing configuration set under User Defined
Routes should be used, or routing configuration using a routing file.
If IPv6 routes are required, the routes must be made using the settings in
Chapter 7.3.2.6 Routing File.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 57 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Via the selection window under Update file and the button Upload now a new routing file can
be uploaded. When uploading the file is checked whether the file is error-free and only then it
is used.
If a routing file has already been uploaded, the uploaded routing file can be downloaded under
Download Routing File.
58 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
After a Factory Default the HTTP and SSH channels are "enabled".
All service settings are valid globally! Services with “disabled” status are not
externally accessible and are not made externally available by the module!
Using SNMP and SNMP- traps the protocol SNMP should be enabled.
All fields must be filled in for a correct operation of SNMP. Contact your network administrator
for details of data not known.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 59 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
In order to disable SNMPv2 both fields SNMP Read Only Community and SNMP Read Write
Community must remain empty.
SNMPv2 SNMPv2 enabled SNMPv2 disabled
Read Only Community: set (e.g. public) empty
Read/Write Community: set (e.g. secret) empty
There are three security levels in SNMPv3 that can be adjusted by the removal of the pass-
phrases:
SNMPv3 noAuthNoPriv authNoPriv authPriv
Authentication Passphrase: empty set set
Privacy Passphrase: empty empty set
60 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 61 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The setting Minimum Accuracy = LOW may lead to the output of non-syn-
chronised (thus possibly wrong) time information.
62 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
7.3.2.9 RADIUS
This page allows the configuration of the RADIUS service (Remote Authentication Dial-In User
Service).
In order to use this service, a correspondingly configured RADIUS server must exist.
Type in 'Friendly name' (e.g. HOPF Device), Client-'Address' (e.g. 192.168.1.123) and a
'Shared secret' key (***).
The address typed in must match the address of the hopf device.
The shared secret key can be chosen freely. It must be repeated in the confirm field. The
chosen key will be required as a secret key during configuration at the hopf device.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 63 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
64 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Here are some password examples and the tunnel passwords to be given:
MySecret 000000084D79536563726574
ABCDEFGHIJKLMNOPQRST 000000144142434445464748494a4b4c4d4e4f5051525354
Use the Enable field to enable and disable the RADIUS service. If the RADIUS service is
disabled, the MASTER and the DEVICE users are used for logging into the web interface. If
the RADIUS service is activated, the RADIUS service is used to log in to the web interface.
The Server Address field must specify the network address of the RADIUS server.
The Secret Key field must display the 'shared secret key' specified on the RADIUS server for
this hopf device.
In the field Master User Secret the 'Tunnel password' must be entered, which has been
specified in the hopf Master network policy.
In the field Device User Secret the 'Tunnel password' must be entered, which has been
specified in the hopf Device network policy.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 65 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The following picture shows the RADIUS configuration on the hopf device, for a RADIUS
server with the address 192.168.1.124 and the shared secret key MySecret.
7.3.2.9.3 Notes
The RADIUS service is only used for the web interface.
If other protocols than http and https are activated in the management
section of Chapter 7.3.2.7 Management (Management-Protocols –
HTTP, SNMP etc.), they continue to use the master and the device user,
therefore the other protocols should be deactivated when using the RA-
DIUS service.
If the RADIUS service is activated after logging in with a user of the master group on the
general page, you will be logged in as master user.
Users who are in the device group will see that they are logged in as device users.
66 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
After all changes relating to NTP a restart of the NTP service must be per-
formed (see Chapter 7.3.3.6 Restart NTP).
Via the NTP protocol SNTP Clients can also be synchronized. In contrast
to NTP in SNTP Clients delay times are not evaluated on the network. For
this reason the accuracy reached in SNTP Clients is lower than in NTP Cli-
ents.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 67 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The Time Server 8030NTS/GPS works as NTP Server with stratum 1 and belongs to the best
available class of NTP server, as it has a reference clock with direct access.
This screenshot shows a maximum kernel clock error of 6.500 msec (milliseconds). The esti-
mated error value is 2 μs (microseconds).
The values indicated here are based on the calculation of the NTP service and have no sig-
nificance for the accuracy of the Sync Source (here Module 8024GPS).
68 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
7.3.3.3 Peers
The "Peers summary" is used to track the performance of the configured NTP server/driver
and the NTP algorithm itself.
The information displayed is identical with the information available via NTPQ or NTPDC pro-
grams.
Each NTP server/driver that has been set up in the NTP server configuration is displayed in
the peer information.
The connection status is displayed in the reachability column (not reachable, bad, medium,
and reachable).
The first line displays the hopf - refclock ntp driver that gets the time information directly
from the Sync Source.
A short explanation and definition of the displayed values can be found in Chapter 13.5 Ac-
curacy & NTP Basic Principles.
The character in the first column on the left presents the current status of the NTP association
in the NTP selection algorithm. A list and description of possible characters can be found in
the Glossary (see Chapter 13.2 Tally Codes (NTP-specific)).
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 69 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The hopf - refclock ntp driver is already configured as standard (127.127.38.0 in the "Peers
Summary") and is not explicitly displayed here.
Based on the selection of GPS, even though GPS is not the source of the
Sync Source (different product option) the value HIGH for Accuracy may
never be reached.
70 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
NTP Clients do not accept time information from a NTP Time Server with
stratum 16 (invalid). Briefly, as long as the Time Server 8030NTS/GPS in-
dicates the stratum value 16, NTP Clients are not synchronized.
This behaviour of NTP during crystal operation of the Sync Source can be changed. Therefore
the function "Switch to specific stratum" should be enabled by setting the value to "enabled"
and the so-called downgrading stratum (= stratum value of the Time Server 8030NTS/GPS
during crystal operation of the Sync Source).
For the synchronization of NTP Clients during crystal operation of the Sync Source or for test-
ing the system without connected synchronization source, in the setting "enabled" any stratum
value between 1 and 15 can be set.
The NTP service MUST also be restarted (see Chapter 7.3.3.6 Restart
NTP).
Using the option "Switch to specific stratum" the NTP Clients are synchro-
nized with time information indicated in the general menu of the WebGUI of
the Sync Source (here Module 8024GPS) during crystal operating. Whether
this time information (e.g. through drift) is imprecise or the time is manually
set (wrong) cannot be detected by the NTP Client!
In case the value 1 is used for "Stratum in crystal operation", the NTP Cli-
ent cannot not verify whether the Time Server 8030NTS/GPS is synchro-
nised or runs in crystal operation. Should a differentiation be wished be-
tween synchronized and crystal operation the downgrading stratum needs
to be set to a value between 2 and 15.
The value is only adjustable if the "Switch to specific stratum" function is enabled.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 71 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
72 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
For activation of this special NTP setting, the customer's approval shown in the WebGUI
needed to be declared by checking the field "I agree".
Entering this function the transmitted time protocol of the Time Server is not
conform to the NTP standard anymore.
According to the NTP standard NTP uses only the UTC time base. The NTP
time protocol does not allow any leaps in time.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 73 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Following configuration steps for the activation of the NTP time ba-
sis are required:
• Select the desired NTP time base.
• Transfer the setting with Apply Changes to the Time Server.
• Fail-save storage of the configuration by pressing Save to Flash
within 10 seconds.
Depending on the activated time base leap a board reset might be
released after transfer with Apply Changes eliminating non saved
configurations.
Using the NTP time protocol with the local time base the summer-/winter
time adjustment is released one to two minutes belated.
Afterwards the local time is correctly available in the NTP time protocol.
Therefore, within this transition period a requested NTP time protocol is re-
plied by the former time base.
Changing the time base for the output of the protocol for NTP is only de-
signed for customized applications and does not correspond with the stand-
ard of NTP. The synchronisation of a standard NTP-Client with a time basis
deviating from UTC results in a wrong time information in the standard NTP-
Client and might cause time leaps!
74 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Restarting NTP services is the only possibility of making NTP changes effective without having
to restart the entire Time Server 8030NTS/GPS. As can be seen from the warning message,
the currently reachable stability and accuracy get lost caused by this restart.
After a restart of the NTP service it takes up to 10 minutes until the NTP
service on the Time Server 8030NTS/GPS is completely adjusted.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 75 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Restrictions are used in order to control access to the System’s NTP service and these are
regrettably the most misunderstood options of the NTP configuration.
If you are not familiar with these options, a detailed explanation can be found at
http://www.ntp.org/.
The following steps show how restrictions can be configured - should these not be required it
is sufficient to retain the standard settings.
The standard restrictions tell the NTP service how to handle packets of hosts (including remote
time servers) and sub-network which otherwise have no special restrictions.
The NTP configuration can simplify the selection of the correct standard restrictions while mak-
ing the required security available.
Before beginning the configuration the points 7.3.3.7.1 to 7.3.3.7.4 must be checked by the
user:
76 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
kod ✓
No
notrap ✓
nopeer ✓
noquery. ✓
In this case select from the following standard restrictions:
See Chapter 7.3.3.7.6 Access Control Options
kod ✓
notrap ✓
Yes nopeer ✓
If a standard restriction is selected in this area, exceptions can be de-
clared in separate lines for each authorised server, client or sub-net-
work. See Chapter 7.3.3.7.5 Addition of Exceptions to Standard Re-
strictions
Yes kod ✓
notrap ✓
nopeer ✓
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 77 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The entry of exceptions also works for IPv6 addresses. For this, the IPv6 address must be
entered in the column IPv4/IPv6 Address and the length of the IPv6 net mask must be entered
in the Netmask column.
78 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Default Settings:
Always active. Can't be modified by the user.
As standard, NTP requires authentication with a symmetric key in order to carry out modifica-
tions with NTPDC. If a symmetric key is not configured for the NTP service, or if this is kept in
a safe place, it is not necessary to use the nomodify option unless the authentication procedure
appears to be unsafe.
Changes in data do not take effect immediately after clicking on the “Ap-
ply” symbol. The NTP service MUST also be restarted (see Chapter
7.3.3.6 Restart NTP).
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 79 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
80 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 81 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
7.3.3.9 Autokey
NTPv4 offers a new Autokey scheme based on public key cryptography.
As a basic principle, public key cryptography is safer than symmetric key cryptography
as protection is based on a private value which is generated by each host and is never visible.
In order to enable Autokey v2 authentication, the “Autokey Enabled” option must be set to
"enabled" and a password specified (may not be blank).
A new server key and certificate can be generated by pressing the "Generate now" button.
Generate now
This should be carried out regularly as these keys are only valid for one
year.
If the Time Server 8030NTS/GPS is to form part of an NTP trust group, a group key can be
defined and uploaded with the "Upload now" button.
Detailed information about the NTP Autokey scheme can be found in the NTP documentation
(http://www.ntp.org/).
Changes in data do not take effect immediately after clicking on the “Ap-
ply” symbol. The NTP service MUST also be restarted (see Chapter
7.3.3.6 Restart NTP).
82 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
PTP Enable
This option activates or deactivates the PTP service.
Remark: Changes in the "Network Interface …" settings in the "NETWORK" tab, can lead to
the deactivation of "PTP Enable".
PTP Interface
This option sets the network interface that is used by the PTP service.
The content of the drop down depends on the settings in the "NETWORK" tab.
If "NIC Bonding / Teaming active" is active, only "BOND0" can be chosen.
If "NIC PRP active" is active, only "PRP0" can be chosen.
If "NIC Bonding / Teaming active" and "NIC PRP active" are inactive, "ETH0" or "ETH1" can
be chosen.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 83 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
PTP Domain
This option controls the PTP domain.
• Value-range: 0 to 255
PTP Priority 1
This option controls the PTP priority 1.
• Value-range: 0 to 255
PTP Priority 2
This option controls the PTP priority 2.
• Value-range: 0 to 255
PTP Profile
This option supports the selection of predefined profiles. Either "None" or "IEEE C37.238
Power Profile" can be selected.
If "IEEE C37.238 Power Profile" is selected, all settings in the "PTP Advanced Settings" win-
dow are set according to the standard IEEE C37.238 and all the settings in that window cannot
be modified. The options in the "PTP IEEE C37.238 Power Profile Settings" window are only
used by the PTP service when this profile is selected.
If "None" is selected, the settings in the "PTP Advanced Settings" window can be modified
and the settings in the "PTP IEEE C37.238 Power Profile Settings" window are not used by
the PTP service.
PTP Grandmaster ID
This option controls the PTP Grandmaster ID.
• Value-range: 3 to 254
84 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
PTP Transport
This setting determines the network protocol that is used by the PTP service.
Possible choices: "Ethernet / P2P", "Ethernet / E2E" and "IPv4 / E2E"
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 85 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
In case of announcing a leap second by the synchronization source the leap second file will
automatically be updated.
86 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
If time server 8030NTS/GPS is not in operation during the whole announcing time, it is not
possible for the application to update its leap second file. The leap second file needs to be
updated next time when time server is put in operation.
UTC-TAI offset
This field shows the actual value, that the PTP service uses, for the difference of UTC and TAI
time.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 87 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
It should be noted that the standard Linux/Unix Syslog mechanism is used for this functionality.
This is not the same as the Windows System Event mechanism!
The alarm level designates the priority level of the messages to be transmitted and the level
from which transmission should take place (see Chapter 7.3.5.4 Alarm Messages).
The NTP service implemented in the system can transmit its own Syslog messages
(see Chapter 7.3.3.4.2 NTP Syslog Messages (General / Log NTP Messages to Syslog)).
88 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
E-mail notification is one of the important features of this device which offers technical person-
nel the opportunity to monitor and/or control the IT environment.
It is possible to configure various, independing E-mail addresses which each have different
alarm levels.
Dependending on the configured level, an E-mail is sent after an error has occurred on the
respective receiver.
A valid E-mail server (SMTP server) must be entered for the purpose of correct configuration.
Some E-mail servers only accept messages if the sender address entered is valid (spam pro-
tection). This can be inserted in the "Sender Address" field.
The Alarm Level designates the priority level of the messages to be sent and determines from
which level the message should be sent (see Chapter 7.3.5.4 Alarm Messages).
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 89 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
SNMP traps are sent to the configured hosts over the network. It should be noted that these
are based on UDP and therefore it is not certain that they will reach the configured host!
Several hosts can be configured. However, all have the same alarm level.
The private hopf enterprise MIB is also available over the web (see Chapter 7.3.6.6 Down-
loading Configuration Files / SNMP MIB).
The Alarm Level designates the priority level of the messages to be sent and determines from
which level the message should be sent (see Chapter 7.3.5.4 Alarm Messages).
The SNMP protocol must be enabled in order to use SNMP (see Chapter
7.3.2.7 Management (Management-Protocols – HTTP, SNMP etc.)).
90 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Depending on the messages, their configured levels and notifications levels of the E-mails, a
corresponding action is carried out if an event occurs.
Modified settings are failsafe stored after Apply and Save only.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 91 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
This tab provides the basic information about the hardware of Module 8030NTS as well as
software/firmware. Password administration and the update services for the module are also
made accessible via this website. The complete download zone is also a component of this
site.
The display "Current DIP Switch Settings" is not applicable for this device.
92 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
This function serves to reset all values in the flash memory to their factory default values.
This also includes passwords (see Chapter 12.1 Factory Default Values of Module
8030NTS (Device)).
Please log in as a "Master" user in accordance with the description in Chapter 7.2.1 LOGIN
and LOGOUT as User
Pressing the "Reset now" button releases setting of the factory default values.
Once this procedure has been triggered there is NO possibility of restoring the deleted config-
uration.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 93 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The restart concerns the Module 8030HEPTA and the Sync Source (here
Module 8024GPS).
All settings not saved with "Save" are lost on Reboot / Hardware Reset
(see Chapter 7.2.3 Enter or Changing Data).
Moreover the NTP service implemented in the system is restarted. This leads to a renewed
alignment phase with the loss of the stability and accuracy reached up to this point.
Log in is carried out as “Master” user in accordance with the description in Chapter 7.2.1
LOGIN and LOGOUT as User Press the "Reboot now" button and wait until the restart has
been performed.
94 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
In order to carry out an update, enter the name and the folder in which the update / firmware
image is located in the text field or open the file selection dialogue by pressing the "Browse"
button.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 95 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The update process is started by pressing the "Update now" button. The update is installed if
the transfer and checksum test are successful. A success page is displayed and shows the
number of bytes that have been transferred and installed.
A restart of the device with the new Firmware is done automatically after the H8-Firmware
update.
The procedure for the Image update differs only in how the device is restarted.
After the image-update the WebGUI displays a window to confirm the restart (reboot) of the
device.
96 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The security information can be written as 'unformatted' text. There are 2000 characters avail-
able to write failsafe into the device.
When saving the text, only the following characters are accepted (all other characters are
discarded and therefore not displayed on the General page!):
• Capital letters (A…Z)
• Lowercase letters (a…z)
• Numbers (0…9)
• The following special characters: space (" "), exclamation mark ("!"), Comma (","), dot
("."), Colon (":"), question mark ("?")
After a successful storage the "Customized Security Banner" with the saved security infor-
mation is displayed in the General-Tab.
To delete the "Customized Security Banner" the inserted text must be deleted and saved
again.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 97 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
For a subsequent order of an activation key the serial number of the Mod-
ule 8030NTS (device) needs to be provided. The serial number can be
found under the tab DEVICE – Device info (serial number 8030…).
The settings for activation keys (e.g. an entered activation key) are neither
deleted nor restored via the function FACTORY DEFAULTS.
98 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Overview
Full listening of all optional functions with the current activation status and stored activation
key
Activate Feature
Input field to enter a new activation key. After entering the feature is activated by pressing the
Apply button.
If the activation was successful the new feature is listed in the overview with status “Active”
and can be used immediately.
Key Reset
Clears all activation keys and sets all optional features to status “Inactive”. All other non-op-
tional features are still available after performing the key reset. If an optional feature is enabled
again, the last stored configuration for this feature is restored.
A new password must contain at least one capital letter and lowercase let-
ter, a number, and six characters.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 99 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The loaded file System Configuration from the module is only used for
support purposes and cannot be reloaded for adjusting the settings in the
Time Server 8030NTS/GPS.
For the download of the file System Configuration the following process
is mandatory:
1. Pressing the button SAVE
2. Pressing the button Refresh System Configuration
3. After approximately 30 seconds, the files are available for the
download
4. Press on the link Configuration Files to update the web site
5. Perform the download of the file
The "private hopf enterprise MIB" is also available via the WebGUI in this area.
100 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
After the data transfer to 8024GPS it can take up to 30 seconds until the mod-
ified data are re-read from 8030NTS for the WebGUI indication.
This delayed indication has no effect on the functionality.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 101 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Announcements
The display fields LEAP SECOND and STD DST announce a corresponding event to the
next hour (insertion of a leap-second or rather switch-over of summer/winter time).
102 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Always the UTC time must be set. The local time is internally calculated
from the difference time (Time Zone Offset) and the summer / winter time
changeover (Daylight Saving Time).
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 103 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
• Offset Hours Time Zone Offset input of the full hour (0-13)
• Offset Minutes Time Zone Offset input of minutes (0-59)
Example:
Time Offset for Germany East, 1 hour and 0 minutes (+ 01:00)
Time Offset for Peru West, 5 hours and 0 minutes (- 05:00)
104 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
After the turn of the year the changeover times for summer/winter time are
automatically recalculated, without any user intervention.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 105 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
Receiver Status
Display of the actual GPS receiver values. For analysing the GPS receiver in case of support.
106 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 107 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
SyncON Timer
The SyncON timer is used to delay the sync-status "SYNC" by the set time although the GPS
receiver is synchronous.
This function is enabled when adjustment processes should be terminated as defined before
the sync status is "SYNC".
This function is not required for this device and should always be set to 0.
SyncOFF Timer
This value is used to provide reception failure bypassing for an error-message free operation
even under poor reception conditions.
In the event of a reception failure of the Sync Source (here Module 8024GPS), the decrease
of the Sync Source to quartz status is delayed by the set value. The system continues to run
in synchronization status on the internally regulated, highly accurate quartz base during this
period with sync status 'SYOF'.
This timer is of special significance when certain system outputs are linked to a specific system
status.
The Timer can be set from 2min. to 1440min.
108 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
This tab indicates information about the hardware and software of the Module 8024GPS (Sync
Source) implemented in the Time Server 8030NTS/GPS.
This function triggers a hardware reset of (just) the Sync Source (here Module 8024GPS).
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 109 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
After setting the Sync Source to factory default values the GPS receiver
needs up to 13 minutes of satellite reception in order to generate the correct
information on the leap second from the GPS data. Only then the Sync
Source (here Module 8024GPS) can be synchronized.
During this time (however only when the GPS receiver really receives satel-
lites) the following message is displayed in the tab Module Errors:
GPS Receiver in raw data mode - no synchronisation
110 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
In order to carry out an update, enter the name and the folder in which the update / firmware
image is located in the text field or open the file selection dialogue by pressing the "Browse"
button.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 111 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
112 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 113 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
114 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
HTTP/HTTPS WEBGUI – WEB BROWSER CONFIGURATION INTERFACE
The output of the status optical coupler (on the front panel of the Time Server 8030NTS/GPS)
can be configured by the use of this function.
The Sync states are listed in this selection window in rising quality from the bottom to the top
(SYNC = optimal condition).
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 115 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
SSH AND TELNET BASIC CONFIGURATION
Only basic configuration is possible via SSH or Telnet. The complete con-
figuration of the Time Server 8030NTS/GPS takes place exclusively via
the WebGUI.
It is just as easy to use SSH (Port 22) or Telnet (Port 23) as the WebGUI. Both protocols use
the same user interface and menu structure.
The user names and passwords are the same as on the WebGUI and are kept in alignment
(see Chapter 7.3.6.5 Passwords (Master/Device)).
The navigation through the menu takes place by entering the respective number associated
with the menu option (as can be seen in the above image).
116 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
FAULT ANALYSIS / TROUBLESHOOTING
If possible, for each problem the entire status in the tabs GENERAL and
GPS SYNC SOURCE page "Module Errors" via WebGUI should always
be checked.
The following describes various effects and their possible causes on a non-synchro-
nizing system:
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 117 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
FAULT ANALYSIS / TROUBLESHOOTING
Case 1:
Effect: After the first installation, no satellite appears on the display after several
hours and 00 is displayed under Satellites in View.
Possible Errors:
• The antenna cable is too long
• An incorrect cable type was used for the length of the antenna equipment
• The antenna cable is faulty
• The antenna cable is not connected
• The antenna is defective
• The indirect lightning protection is defective
Case 2:
Effect: There are 7 satellites in the visibility range (V=07) but a maximum of 2 appear
on the display frame. However, the value of these satellites is 70 or above.
Possible Errors:
• The visibility range of the antenna to the sky is limited and the Module
8024GPS set to 3D reception mode.
Case 3:
Effect: There are 9 satellites in the visibility range (V=09) and 6 appear on the display
frame. The signal/noise ratios are all below 30. The equipment is not synchro-
nized.
Possible Errors:
• The cable is too long
• An incorrect cable type was used for the length of the antenna equipment
• The BNC connectors are poorly mounted
• The cable is bent or crimped
• Indirect lightning protection was irreversibly damaged by overvoltage
• The antenna is defective
Case 4:
Effect: The equipment was working perfectly but has not been receiving for several
days. 7 satellites appear in the visibility range (V=07) but no satellite is dis-
played.
Possible Errors:
• The cable has been damaged
• There was excess voltage on the antenna equipment and the indirect light-
ning protector is defective
• The antenna is defective
• The GPS receiver of Module 8024GPS is defective
• A building change has had an effect on the antenna equipment (e.g. shading
of the antenna caused by subsequent building installation, or the laying of
cables with a high electrical alternating field in the immediate vicinity of the
GPS antenna cable)
• Electronic equipment with an interference effect on the GPS signal has been
put into operation in the vicinity of the GPS antenna equipment / GPS re-
ceiver (e.g. transmitter for pagers)
Further information on the subject of the GPS antenna system can be consulted in the manual
"Antenna Equipment GPS".
118 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
FAULT ANALYSIS / TROUBLESHOOTING
Description
• There is no "DST" for “daylight saving time“ (summer time) displayed in the Sync
Source time in WebGUI
• Summer time is not considered in outputs working with it and even in case of availibilty.
If possible, for each problem the Configuration File in the tab DEVICE
should be downloaded from the device and be sent to the hopf support
(see Chapter 7.3.6.6 Downloading Configuration Files / SNMP MIB).
• With the file System Configuration or if not possible with the serial number of the
System
• When does the error occur: During commissioning or operation
• Exact error description
• In the case of GPS reception/synchronization problems description of the antenna
equipment used:
o Components used (antenna, indirect lightning protection, etc.)
o Cable type used
o Total length of the antenna system
o Sequence of components and cable lengths between the components
o Antenna installation site (e.g. signal shading by building)
Please write to the following E-mail address with the above information:
support@hopf.com
Providing a detailed error description and above listed information avoid the
need for additional clarification and leads to a faster processing by the sup-
port team.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 119 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
MAINTENANCE
10 Maintenance
The Time Server 8030NTS/GPS is generally maintenance-free. The following points should
be observed if a cleaning of the system might be necessary.
The use of such cleaning agents or media could damage the Time Server 8030NTS/GPS.
Make sure that connections or cables are not loosened while cleaning the
housing of the Time Server 8030NTS/GPS. There is the danger of dam-
age and functionality loss.
120 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
TECHNICAL DATA
11 Technical Data
The company hopf reserves the right to hardware and software altera-
tions at any time.
Ambient Conditions
Temperature range: Operation: 0°C to +50°C
Storage: -20°C to +75°C
Humidtiy: max. 95%, non condensing
CE Conformity
EMV Directive 2014/30/EU
EN 55022 : 2010 / AC : 2011
EN 61000-3-2 : 2006 / A2 : 2009, EN 61000-3-3 : 2013
EN 55024 : 2010
Low Voltage Directive 2014/35/EU
EN 60950-1 : 2006 / AC : 2011
MTBF
MTBF > 250,000h
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 121 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
TECHNICAL DATA
LAN - ETH0/ETH1
Network connection Via a LAN cable with RJ45 connector, male
(recommended cable type CAT5 or better)
Request per second Max. 6,250 requests (during operation in GigaBit
networks under optimum network conditions)
Number of connectable Clients Theoretically unlimited
Network interface ETH0 10/100/1000 Base-T
Ethernet compatibility Version 2.0 / IEEE 802.3
Isolation voltage 1500 Vrms
(Network- to system side)
Boot time: typ.: 35 seconds
- When using static IP addresses for ETH0 and ETH1.
Depending on the network configuration in use (e.g.
DHCP) an extension of the boot phase can occur.
GPS-System - Accuracy
Lambda < 15ms Stability < 0.2ppm HIGH
Lambda < 15ms Stability >= 0.2ppm and <= 2ppm, Offset < 1ms HIGH
Lambda < 15ms Stability > 2ppm or Offset >= 1ms MEDIUM
DCF77-System - Accuracy
Lambda < 15ms Stability < 0.6ppm HIGH
Lambda < 15ms Stability >= 0.6ppm and <= 2ppm, Offset < 2ms HIGH
Lambda < 15ms Stability > 2ppm or Offset >= 2ms MEDIUM
Time Protocols
• NTPv4 Server
• NTP Broadcast Mode
• NTP Multicast Mode
• NTP Client for additional NTP Servers (Redundancy)
• SNTP Server
• NTP Symmetric Key Encryption
• NTP Autokey Encryption
• NTP Access Restrictions
• RFC-867 DAYTIME Server
• RFC-868 TIME Server
• SINEC H1 time datagram (Activation key required)
TCP/IP Network Protocols
• HTTP/ HTTPS
• DHCP
• Telnet
• SSH
• SNMP (Activation key required)
• SMTP (Activation key required)
• SYSLOG (Activation key required)
Configuration Channels
• HTTP/HTTPS-WebGUI (Browser Based)
• Telnet
• SSH
• hmc Remote Access
• External LAN configuration tool (hmc - Network-Configuration-Assistant)
122 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
TECHNICAL DATA
GPS Data
Receiver type: 22 channel phase tracking receiver, C/A code
Evaluation: L1 frequency (1575.42MHz)
Sensitivity: Tracking: -161dB
Cold Start: -148dBm
Synchronization time • Warm start: < 1min.
TTF (Time to First Fix): • Cold start: < 5min
• first installation < 12.5 min
(without valid leap second information)
Antenna connection: • Via BNC connector, female
• For active antennas,
Ub = 5VDC / max. 70mA
• Antenna power feed via BNC connector, fe-
male of Module 8024GPS
Signal Outputs
Status optical coupler: Via 3-pole pluggable screw terminal
Resistive circuit-breaking capacity:
max. 50mA / 80VDC
Special production:
Modifications can be made to hardware and software in accordance with customer specifica-
tions.
The hopf Company reserves the right to modify hardware and software at any
time.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 123 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
TECHNICAL DATA
Internal
Power Supply hopf Type: AC-M05-D hopf Type: AC-M10-D
(Only wide input range)
Input Data
Input voltage range 85-264VAC 85-264VAC
100-250VDC 100-250VDC
Frequency 47-440Hz 47-440Hz
0 Hz 0 Hz
Current consumption approx. 0.15A (100VAC) approx. 0.30A (100VAC)
(at nominal values) 0.10A (200VAC) 0.20A (200VAC)
Inrush current typ. 15A (IO = 100%) 100VAC typ. 15A (IO = 100%) 100VAC
typ. 30A (IO = 100%) 200VAC typ. 30A (IO = 100%) 200VAC
Hold-up time > 20msec. (> 100VAC) > 20msec. (> 100VAC)
at nominal laod
Start-up time after connected < 1 sec. < 1 sec.
mains voltage
Transient overvoltage protection Overvoltage protection III Overvoltage protection III
(EN 60664-1) (EN 60664-1)
Protection supply, internal 400 mA slow blow 400 mA slow blow
(device protection) (device protection)
Recommended Circuit breaker 6A, Circuit breaker 6A,
back-up fuse (AC) 10A charakteristics B 10A charakteristics B
(EN 60898) (EN 60898)
Leakage current against PE < 0.5mA (60Hz, according to < 0.5mA (60Hz, according to
EN 60950) EN 60950)
Input isolation voltage / PE 2000VAC, 1 minute, 2000VAC, 1 minute,
leakage current = 10mA, leakage current = 10mA,
500VDC, 50MOhm min. 500VDC, 50MOhm min.
(at room temperature) (at room temperature)
124 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
TECHNICAL DATA
DC Power Supplies
Input Data
Input voltage range 18-36VDC 36-76VDC
Current consumption (at nominal approx. 0.69A Approx. 0.35A
values)
Start-up time after connected < 200msec. < 200msec.
mains voltage
Protection supply internal 2A fast blow 1A fast blow
(Device protection)
Input isolation voltage 1,500VDC 1,500VDC
Input / Output 1 minute, 500VDC 50M 1 minute, 500VDC 50M
min. (20°C 15°C) min. (20°C 15°C)
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 125 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
11.5
126 / 144
Front View Side View
Klammerbefestigung für
105,00 (4.13")
105,00 (4.13")
35mm Hutschienenmontage (DIN EN 50 022)
W
L
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
FACTORY DEFAULTS OF TIME SERVER 8030NTS/GPS
Using the board in DCF77 sytems (different product variant) the setting for
NTP / General / Sync Source" needs to be re-configured to "DCF77" af-
ter a factory default.
12.1.1 Network
Host/Name Service Setting WebGUI
Hostname hopf8030nts hopf8030nts
Use Manual DNS Entries Enabled Enabled
DNS Server 1 IPv4/IPv6 Address Blank ---
DNS Server 2 IPv4/IPv6 Address Blank ---
DNS Server 3 IPv4/IPv6 Address Blank ---
Use Manual Gateway Entries Enabled Enabled
Default Gateway IPv4 Address Blank ---
Default Gateway IPv6 Address Blank ---
Network Interface ETH0 Setting WebGUI
Use Custom Hardware Address (MAC) Disabled Disabled
Custom Hardware Address (MAC) Blank ---
DHCP Disabled Disabled
IPv4 192.168.0.1 192.168.0.1
IPv4-Netmask 255.255.255.0 255.255.255.0
Operation mode Auto negotiate Auto negotiate
VLAN Interfaces deaktiviert disabled
IPv6 Settings deaktiviert disabled
Network Interface ETH1 Setting WebGUI
Use Custom Hardware Address (MAC) Disabled Disabled
Custom Hardware Address (MAC) Blank ---
DHCP Enabled Enabled
IPv4 Blank ---
IPv4-Netmask Blank ---
Operation mode Auto negotiate Auto negotiate
VLAN Interfaces Disabled Disabled
IPv6 Settings Disabled Disabled
Bonding Setting WebGUI
Network Interface Bonding/Teaming Disabled Disabled
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 127 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
FACTORY DEFAULTS OF TIME SERVER 8030NTS/GPS
128 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
FACTORY DEFAULTS OF TIME SERVER 8030NTS/GPS
12.1.2 NTP
NTP Server Configuration Setting WebGUI
Sync Source GPS GPS
NTP to Syslog Disabled Disabled
Switch to specific stratum Disabled Disabled
Stratum in crystal operation Blank ---
Broadcast address Blank ---
Authentication Disabled None
Key ID Blank ---
Additional NTP Servers Blank ---
NTP Extended Configuration Setting WebGUI
Limitation of Liability Blank ---
Block Output when
Disabled Disabled
Stratum Unspecified
12.1.3 PTP
PTP Configuration Setting WebGUI
PTP Enabled disabled disabled
PTP Interface ETH0 ETH0
PTP Domain 0 0
PTP Priority 1 128 128
PTP Priority 2 128 128
PTP Profile IEEE C37.238 Power Profile IEEE C37.238 Power Profile
PTP IEEE C37.238
Setting WebGUI
Power Profile Settings
PTP Grandmaster ID 3 3
Time Zone Name UTC UTC
PTP Advanced Settings Setting WebGUI
PTP Transport Ethernet / P2P Ethernet / P2P
PTP sync interval (2^x sec) 1 second 0
PTP pdelay request interval (2^x sec) 1 second 0
PTP announce interval (2^x sec) 1 second 0
PTP announce timeout (sec) 2 seconds 2
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 129 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
FACTORY DEFAULTS OF TIME SERVER 8030NTS/GPS
12.1.4 ALARM
Syslog Configuration Setting WebGUI
Syslog Disabled Disabled
Server Name Blank ---
Alarm Level Disabled None
E-mail Configuration Setting WebGUI
E-mail Notifications Disabled Disabled
SMTP Server Blank ---
Sender Address Blank ---
E-mail Addresses Blank ---
SNMP Traps Configuration Setting WebGUI
SNMP Traps Disabled Disabled
Alarm Level Disabled None
SNMP Trap Receivers Blank ---
Alarm Messages Setting WebGUI
Alarms All disabled All none
12.1.5 DEVICE
User Passwords Settings WebGUI
Master Password master ---
Device Password device ---
Diagnostic Settings WebGUI
Real Time Diagnostics Disabled Disabled
Product Activation Settings WebGUI
Activate Feature No changes No changes
130 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
GLOSSARY AND ABBREVIATIONS
x falsetick The peer was picked out by the NTP intersection algorithm
as a false time supplier.
. excess The peer was picked out by the NTP sort algorithm as a
weak time supplier on the basis of synchronization distance
(concerns the first 10 peers).
- outlyer The peer was picked out by the NTP clustering algorithm as
an outlyer.
+ candidate The peer was selected as a candidate for the NTP combining
algorithm.
# selected The peer is of good quality but not among the first six peers
selected by the sort algorithm on the basis of synchroniza-
tion distance.
* sys.peer The peer was selected as a system peer. Its characteristics
are transferred to the Base System.
o pps.peer The peer was selected as a system peer. Its characteristics
are transferred to the Base System. The current synchroni-
zation is derived from a PPS (pulse-per-second) signal either
indirectly via PPS reference clock driver or directly via kernel
interface.
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 131 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
GLOSSARY AND ABBREVIATIONS
132 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
GLOSSARY AND ABBREVIATIONS
13.3 Abbreviations
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 133 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
GLOSSARY AND ABBREVIATIONS
13.4 Definitions
An explanation of the terms used in this document.
See RFC 2131 Dynamic Host Configuration Protocol for further infor-
mation.
134 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
GLOSSARY AND ABBREVIATIONS
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 135 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
GLOSSARY AND ABBREVIATIONS
Thus the QoS (Quality of Service) used for direct synchronization with GPS or serial interface
does not apply to synchronization via NTP.
In simplified terms, accuracies of between 1msec and 1sec can be expected, depending on
the accuracies of the servers used.
NTP has a variety of algorithms to equalise the possible characteristics of IP networks. Algo-
rithms also exist to equalise the offset between reference time source and the local clock.
However, under some circumstances it is not possible to provide an algorithmic solution.
For example:
1. Time servers which do not deliver any correct time cannot be detected at all. The only
option available to NTP is to mark these time servers as FALSETICKERS in compar-
ison to other time servers and to disregard them. However, this means that if only 2
time servers are configured, NTP has no way of determining the correctness of the
individual times and clearly identifying which time is incorrect.
2. Asymmetries in the transmission between NTP servers and NTP clients can neither
be measured nor calculated by NTP. NTP works on the assumption that the transmis-
sion path to the NTP server is exactly as long as the return path. The NTP algorithm
can only filter out changes on a statistical basis. The use of several servers makes it
possible for the combining algorithm to pick up and filter out any such errors. However,
there is no possibility of filtering if this asymmetry is present on all or most of the NTP
servers (faulty routing etc).
3. It goes without saying that the accuracy of the synchronised time cannot be better
than the accuracy resolution of the local clock on the NTP server and NTP client.
136 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
LIST OF RFCS
With reference to the above mentioned error circumstances, the delivered time offset of the
NTP should be considered to be at best the most favourable case and in no way to be a value
that takes account of all possible errors.
In order to resolve this problem, NTP delivers the maximum possible error in relation to the
offset. This value is designated as the synchronization distance ("LAMBDA") and is the sum
of the Root Dispersion and half of the Root Delay of all NTP servers used. This value de-
scribes the worst possible case and thus the maximum error that can be expected.
Finally, please note that the user of the Time Server is responsible for the network conditions
between the Time Server and the NTP clients.
As an example, we mention the case where a network has a delay of 500msec and an accu-
racy shift (asynchronization.) of 50msec occurs. The synchronised clients will therefore
NEVER achieve accuracy values of one millisecond or even microseconds!
The accuracy value in the GENERAL tab of the WebGUI is designed to help the user to esti-
mate the accuracy.
14 List of RFCs
• NTPv4 - Protocol and Algorithms Specification (RFC 5905)
• NTPv4 - Autokey Specification (RFC 5906)
• PPS API (RFC 2783)
• DHCP (RFC 2131)
• Time Protocol (RFC 868)
• Daytime Protocol (RFC 867)
• HTTP (RFC 2616)
• HTTPS (RFC 2818)
• SSH-2 (RFC 4250-4256, 4335, 4344, 4345, 4419, 4432, 4716, 5656)
• TELNET (RFC 854-861)
• SNMPv2 (RFC 1213, RFC1901-1908)
• SNMPv3 (RFC 3410-3418)
• SYSLOG (RFC 5424)
• SMTP (RFC 5321)
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 137 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
LIST OF OPEN SOURCE PACKAGES USED
The following table includes all used software packages with the applicable underlying soft-
ware license conditions:
138 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
LIST OF OPEN SOURCE PACKAGES USED
gd 2.1.1 BSD no
genext2fs 1.4.1 - no
gzip 1.6 GPL v2 no
host-auto- 2.69 GPL v3 no
conf
host-au- 1.15 GPL v2 no
tomake
host-bison 3.0.4 GPL v3 no
host- 7.3.1 BSD no
dos2unix
host- 1.42.13 GPL v2 no
e2fsprogs
host-flex 2.5.37 Flex carries the copyright used for BSD software, slightly no
modified because it originated at the Lawrence Berkeley
(not Livermore!) Laboratory, which operates under a con-
tract with the Department of Energy:
Copyright (c) 2001, 2002, 2003, 2004, 2005, 2006, 2007
The Flex Project.
Copyright (c) 1990, 1997 The Regents of the University of
California.
All rights reserved.
This code is derived from software contributed to Berkeley
by Vern Paxson.
The United States Government has rights in this work pur-
suant to contract no. DE-AC03-76SF00098 between the
United States Department of Energy and the University of
California.
Redistribution and use in source and binary forms, with or
without modification, are permitted provided that the fol-
lowing conditions are met:
1. Redistributions of source code must retain the above
copyright notice, this list of conditions and the following
disclaimer.
2. Redistributions in binary form must reproduce the
above copyright notice, this list of conditions and the
following disclaimer in the documentation and/or other
materials provided with the distribution.
Neither the name of the University nor the names of its
contributors may be used to endorse or promote products
derived from this software without specific prior written
permission.
THIS SOFTWARE IS PROVIDED ``AS IS'' AND WITH-
OUT ANY EXPRESS OR IMPLIED WARRANTIES, IN-
CLUDING, WITHOUT LIMITATION, THE IMPLIED WAR-
RANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE.
This basically says "do whatever you please with this soft-
ware except remove this notice or take advantage of the
University's (or the flex authors') name".
Note that the "flex.skl" scanner skeleton carries no copy-
right notice. You are free to do whatever you please with
scanners generated using flex; for them, you are not even
bound by the above copyright.
host-gen- 1.4.1 GPL v2 no
ext2fs
host- 0.19.7 GPL v3 no
gettext
host-kmod 22 LGPL v2.1 no
host-libffi 3.2.1 libffi - Copyright (c) 1996-2014 Anthony Green, Red Hat, no
Inc and others. See source files for details.
Permission is hereby granted, free of charge, to any per-
son obtaining a copy of this software and associated doc-
umentation files (the ``Software''), to deal in the Software
without restriction, including without limitation the rights to
use, copy, modify, merge, publish, distribute, sublicense,
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 139 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
LIST OF OPEN SOURCE PACKAGES USED
140 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
LIST OF OPEN SOURCE PACKAGES USED
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 141 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
LIST OF OPEN SOURCE PACKAGES USED
142 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
LIST OF OPEN SOURCE PACKAGES USED
GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01 143 / 144
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com
LIST OF OPEN SOURCE PACKAGES USED
144 / 144 GPS - NTP Time Server with 2x 10/100/1000 MBit LAN Interface 8030NTS/GPS - V06.01
hopf Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: info@hopf.com