Nothing Special   »   [go: up one dir, main page]

Outdoor UPS Brochure

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

OUTDOOR

SINGLE-PHASE
UPS
UP TO 2000VA

THE SOURCE OF POWER


SINGLE PHASE
Designed for UPS
outdoor application Provides continuous power to critical loads during
with wide operating blackout in rugged environment
temperature range Wide operating temperature range from -40°C to 70°C
suits for outdoor applications
Built-in boost and buck AVR to regulate input voltage
Selectable transfer time for normal or generator
modes
Provides RS-232, USB and SNMP intelligent port
Circuit breaker protection on AC input, AC output and
external battery input
User-adjustable charging current
Adjustable input threshold voltage
Provides programmable signals for dry contacts
Battery compensation design will optimize battery
lifecycle

-40°C +70°C

ULTRA WIDE TEMPERATURE RANGE


OUTDOOR
UPS - Single phase

General characteristics
Nominal power (VA) 2000
Active power (W) 1600
Technology Line interactive
Waveform Sinusoidal
Architecture UPS with extendable backup
time
Input characteristics
Input voltage 120 or 230 V
Input frequency 50/60 Hz Autosensing
Input voltage range 100-130 Vac or 170÷300 Vac
Output characteristics
Output voltage 120 or 230 V ± 5 %
Efficiency @AC mode Up to 95 %
Efficiency @AVR mode Up to 90 %
Output frequency (nominal) 50/60 Hz ±0,1 %
THD of output voltage <3% with linear load
Transfer time:

Application area: Normal mode


Generator mode
12 ms
15 ms

Batteries
• Roadway Caution Signs Backup time extension Yes
• Railway Telecom Systems Battery voltage
Charging current
48 Vdc
Up to 10A
• Radio Base Stations & Repeaters Communication and management
• SCADA Systems Signaling LED status indicator, alarms and
audible signaling
• Tower and Obstruction Lighting
• Remote Telemetry Communication ports 1 RS232 serialport, 1 slotfornetwork
interfaceconnection
• Video Cameras Mechanical characteristics
133 x 240 x
• Gate Openers Dimensions (H x W x D) (mm) 400
• Security Systems Ambient conditions
Ambient operating temperature (°C) -40÷70
• LED Traffic Controls Relative humidity (%) 5%÷90% non-condensing
• Wi-Fi/WiMax Back-up Power Noise at 1 m (dBA) ‹ 48
• Low Voltage Lighting
Headquarters
Emek Mah. Ordu Cad. No:51
Sancaktepe/Istanbul/Turkey
☎ : +90 (0) 216 622 58 00
Fax : + 90 (0) 216 622 46 51

In accordance with its policy


of continuous improvement, the
Company reserves the right to change
specifications and designs without
notice. All illustrations, descriptions,
dimensions and weights in this
catalogue are for guidance and cannot
be held binding on the Company.

You might also like