Adpatador TS
Adpatador TS
Adpatador TS
___________________
___________________
Product overview 2
___________________
Mounting 3
SIMATIC
___________________
Connecting 4
Industrial Software Engineering
Tools TS module modem 5
___________________
Modular TS Adapter
6
___________________
TS Module ISDN
Manual
7
___________________
TS Module RS232
8
___________________
TS Module GSM
9
___________________
Technical data
06/2011
A5E02615140-02
Legal information
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.
CAUTION
without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.
NOTICE
indicates that an unintended result or situation can occur if the relevant information is not taken into account.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
1 Preface ...................................................................................................................................................... 5
2 Product overview ....................................................................................................................................... 7
2.1 Components...................................................................................................................................7
2.2 Hardware Requirements ................................................................................................................9
3 Mounting.................................................................................................................................................. 11
3.1 Connect TS Adapter and TS Module...........................................................................................11
3.2 Installing on the S7-300 standard rail ..........................................................................................13
3.3 Installation on a standard rail .......................................................................................................15
3.4 Wall mounting ..............................................................................................................................17
3.5 Cubicle Mounting .........................................................................................................................18
4 Connecting .............................................................................................................................................. 19
4.1 Change the voltage......................................................................................................................19
4.2 Connecting cables .......................................................................................................................21
5 TS module modem .................................................................................................................................. 23
5.1 Scope of delivery and replacement parts for the TS Module modem..........................................23
5.2 Properties of the TS module modem ...........................................................................................24
5.3 LED display of the TS Module modem ........................................................................................27
5.4 Technical data of the TS Module modem ....................................................................................29
6 TS Module ISDN...................................................................................................................................... 31
6.1 Scope of delivery and replacement parts of the TS Module ISDN ..............................................31
6.2 Properties of the TS module ISDN...............................................................................................32
6.3 LED display of the TS Module ISDN............................................................................................34
6.4 Technical data of the TS Module ISDN .......................................................................................36
7 TS Module RS232 ................................................................................................................................... 39
7.1 Scope of deliver of the TS module RS232...................................................................................39
7.2 Properties of the TS module RS232 ............................................................................................40
7.3 LED display of the TS Module RS232 .........................................................................................43
7.4 Technical data of the TS Module RS232 .....................................................................................44
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 3
Table of contents
Modular TS Adapter
4 Manual, 06/2011, A5E02615140-02
Preface 1
Purpose of this manual
This manual provides a comprehensive overview of the modular TS Adapter. It supports you
during the installation and setting up of the hardware. It explains the requirements for
operation and the hardware installation, and how to connect the individual components to the
Ethernet and the telephone network.
The intended readership of the manual includes programmers and engineering personnel
involved in configuration, commissioning and servicing of automation systems.
Supplementary documentation
You can find information on PROFINET and Ethernet in the following documentation:
Documentation Contents
PROFINET system description Basic knowledge of PROFINET: Network component,
System manual data exchange and communications, PROFINET IO,
Component Based Automation, application example -
PROFINET IO and Component Based Automation
SIMATIC NET: Twisted-pair and fiber- Description of Industrial Ethernet networks, network
optic networks configuration, components, installation regulations for
Manual networked automation systems in buildings, etc.
Communication with SIMATIC Basics, services, networks, communication functions,
Manual connecting PGs/OPs, project design and configuration in
STEP 7
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 5
Preface
This manual contains a description of the components which were valid at the time the
manual was published.
Modular TS Adapter
6 Manual, 06/2011, A5E02615140-02
Product overview 2
2.1 Components
2
1
5
4
Only the combination of a basic unit and a TS Module forms a complete functional unit (total
unit). Basic unit and TS Module are connected and assembled together through a connector.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 7
Product overview
2.1 Components
Basic unit
The functions of the TS Adapter are implemented in the basic unit. The basic unit has an
Ethernet port for the connection to a PG or to a PC or to the automation system. The basic
unit is supplied and grounded with DC 24 V through a 3-pin socket board.
Use the following as a basic unit:
● TS Adapter IE Basic
More information about this can be found in the manual from the respective basic unit.
TS Module
The TS Module forms the electrical interface to the telephone network. The TS Modules are
supplied with electricity from the basic unit through the shared connector.
The following TS Modules exist:
● TS module modem (Page 23)
The TS Module Modem contains an analog modem for the connection to the analog
telephone network.
● TS Module ISDN (Page 31)
The TS Module ISDN contains a terminal adapter for the connection to the ISDN network.
● TS Module RS232 (Page 39)
The TS Module RS232 has a RS232 interface for the connection of an external modem.
● TS Module GSM (Page 45)
The TS Module GSM contains a radio modem for connection to the GSM/GPRS network.
More information about the individual TS modules can be found in the respective chapters of
this manual.
Modular TS Adapter
8 Manual, 06/2011, A5E02615140-02
Product overview
2.2 Hardware Requirements
Overview:
● In order to fulfill the installation requirements for UL, you must use a UL-listed NTBA on
the TS Module ISDN. NTBA = Network Terminal Basic Adapter
● TS Module Modem: The following telephone cable is prescribed for compliance of the UL
requirements:
Phone cable of UL category DUXR, consisting of a line plus connector, with a
cross-section of AWG 26.
The supplied cable fulfills this requirement.
● TS Module RS232: All conventional modems permitted for industrial use can be
connected to the TS Module RS232.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 9
Product overview
2.2 Hardware Requirements
Modular TS Adapter
10 Manual, 06/2011, A5E02615140-02
Mounting 3
3.1 Connect TS Adapter and TS Module
Before assembly
Before the assembly of the modular TS Adapter, the basic unit and the TS Module must be
connected:
2 1
4
6
① Basic unit
② TS Module
③ Plug connector from the TS module
④ Elements
⑤ Ethernet port
⑥ Cannot be opened!
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 11
Mounting
3.1 Connect TS Adapter and TS Module
CAUTION
A TS Module can be damaged if you touch the contacts of the plug connector sticking out
sideways of the TS Module.
Follow the EGB directives and directions in order to avoid damaging the TS Module through
electrostatic discharge.
Before you assemble the TS Module and the basic unit make sure that both are in a de-
energized state and that all mounting parts (busbars, plates, etc.) are connected with the
protective conductor.
CAUTION
Mounting methods
You have the following alternatives for the mounting of the TS Adapter and TS Module:
● Installing on the S7-300 standard rail (Page 13)
● Installation on a standard rail (Page 15)
● Wall mounting (Page 17)
● Cubicle Mounting (Page 18)
Modular TS Adapter
12 Manual, 06/2011, A5E02615140-02
Mounting
3.2 Installing on the S7-300 standard rail
Requirement
● You have connected the basic unit and TS Module to the total unit.
● The S7-300-mounting rail is installed.
Mounting
1. Hang the standard rail adapter (optional) ② on the upper edge of the S7-300-standard
rail ①.
2. Clamping the profile rails adapter ② with both screws ③ to the S7-300-standard rail ①.
3. Hang the total unit ④ in the standard rail profile of the adapter ② and move it backwards
until you hear it lock. Make sure that you position the total unit directly above the fixing
bolt.
1
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 13
Mounting
3.2 Installing on the S7-300 standard rail
Dismounting
WARNING
Remove the plug of the analog cable and Ethernet cable from the TS Module and from the
basic unit before you remove the voltage and thus, separate the grounding of the TS
Adapter.
1. Remove both latching mechanisms on the underside of the basic unit and TS Module
with a screwdriver and disengage the latching mechanism.
2. Move the basic unit and TS Module forwards out of the standard rail profile.
Modular TS Adapter
14 Manual, 06/2011, A5E02615140-02
Mounting
3.3 Installation on a standard rail
Requirement
● You have connected the basic unit and TS Module to the total unit.
● The DIN rail is mounted.
Mounting
Note
If you install the total unit in vertical installation or in an environment with strong vibrations,
use the end bracket 8WA1 808 on the DIN rail to prevent that the TS Module comes off the
TS Adapter IE Basic.
You can also use screws as described in section "Wall mounting (Page 17)".
CAUTION
TS Module GSM
Always use the end retainers 8WA1 808 with the TS Module GSM to prevent loosening of
the TS Module from the TS Adapter IE Basic.
① DIN rail
② Total unit
Figure 3-3 Mounting on DIN Rails
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 15
Mounting
3.3 Installation on a standard rail
Dismounting
WARNING
Remove the plug of the analog cable and Ethernet cable from the TS Modul and from the
basic unit before you remove the voltage and thus, separate the grounding of the
TS Adapter.
1. Remove both latching mechanisms on the underside of the TS Adapter and TS Module
with a screwdriver and disengage the latching mechanism.
2. Move the basic unit and TS Module forwards out of the standard rail.
Modular TS Adapter
16 Manual, 06/2011, A5E02615140-02
Mounting
3.4 Wall mounting
Requirement
You have connected the basic unit and TS Module.
Mounting
1. Move the attachment slider ① to the backside of the basic unit and TS Module in the
direction of the arrow until it engages.
2. Screw the basic unit and TS module to the position marked with ② to the designated
assembly wall.
The following image shows the total unit in the view from behind with the attachment sliders
① in both positions:
2
1
① Attachment slider
② Drill holes for wall mounting
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 17
Mounting
3.5 Cubicle Mounting
PP
PP PP
PP
The clearance from the front of the module to the cubicle lid and front door must be at least
25 mm.
Modular TS Adapter
18 Manual, 06/2011, A5E02615140-02
Connecting 4
4.1 Change the voltage
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 19
Connecting
4.1 Change the voltage
Procedure
To change the voltage, proceed as follows:
1. If you want to use ferrules, isolate the wires to 10 mm. Cap the crimp ferrules with the
lines.
Strip about 8 to 10 mm off the wires.
2. Place the cores on (①).
3. Screw the ends of the cores with the voltage, tightening torque: 0.6 to 0.8 Nm (②).
L+ 24 V DC
M Ground
Ground connection
Plug on voltage
place the wired voltage ① until it locks into the power socket.
① Voltage
Modular TS Adapter
20 Manual, 06/2011, A5E02615140-02
Connecting
4.2 Connecting cables
Requirement
The following requirements must be met:
● You have connected the TS Adapter basic unit and the TS Module.
● You have mounted the total unit (TS Adapter-Basic Unit + TS Module).
● You have wired the voltage (Page 19) with which the total unit is supplied with DC 24 V.
Safety information
WARNING
Connecting lines
1. Make sure that the power supply for the total unit is turned off.
2. Place the wired voltage for the TS Adapter on the socket board for the power supply with
DC 24 V.
3. Connect the lines for L+ and M to the DC 24 V power supply.
4. Connect the ground connection of the TS Adapter to the ground.
5. With the help of the Ethernet cable, establish the connection from the TS Adapter to the
PG/PC or to the automation system.
6. Establish the connection between the TS Module and telephone network.
7. Switch on the power supply for the total unit.
Separating lines
1. Switch off the power supply for the total unit.
2. Disconnect the connection between the TS Module and telephone network.
3. Disconnect the remaining connections.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 21
Connecting
4.2 Connecting cables
Modular TS Adapter
22 Manual, 06/2011, A5E02615140-02
TS module modem 5
5.1 Scope of delivery and replacement parts for the TS Module modem
Product package
Spare parts
Please order the spare parts from your local Siemens representative.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 23
TS module modem
5.2 Properties of the TS module modem
Properties
The TS Module Modem has an internal analog modem.
The analog modem port is the 6-pin RJ11 socket behind the lower front panel. See the
image in the chapter LED display of the TS Module Modem
Modular TS Adapter
24 Manual, 06/2011, A5E02615140-02
TS module modem
5.2 Properties of the TS module modem
P RES
P
5- 5-
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 25
TS module modem
5.2 Properties of the TS module modem
Note
Use the supplied cable with ferrite to comply with EMC values and make sure that the ferrite
is on the module side.
Note
How to connect the RJ11 connector:
1. Grasp the cable just below the RJ11 connector.
2. Make sure the RJ11 connector engages audibly.
Note
To use the TS Module Modem outside Germany, you can fit a country-specific TAE
connector onto the RJ11 connector of the phone cable. For Germany, a TAE6N connector is
supplied. In some countries phone sockets with RJ11 ports are available, so you can use the
phone cable without a TAE connector.
See also
LED display of the TS Module modem (Page 27)
Modular TS Adapter
26 Manual, 06/2011, A5E02615140-02
TS module modem
5.3 LED display of the TS Module modem
Overview
The following image shows the LEDs on the front side of the TS Module Modem. The LEDs,
DCD, RxD and TxD are located behind the upper front panel. The TS Module Modem is
illustrated in the image without front panels.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 27
TS module modem
5.3 LED display of the TS Module modem
Start-up characteristics
The LED ON is switched on when the power is restored.
Modular TS Adapter
28 Manual, 06/2011, A5E02615140-02
TS module modem
5.4 Technical data of the TS Module modem
Specifications
● Dimensions: Approx. H 100 x L 30 x W 75 mm
● Weight: Approx. 98 g
● ITU transmission standards:
V.21, V.22, V.22bis, V.23, V.32, V.32bis, V.34, V.34x, K56flex, V.90, V.92
● Error correction and data compression
● a/b port
● Hayes (AT) command set
● All data formats
● Dial procedures: Dual-tone multiple-frequency (DTMF), pulse dialing
Country list
Explicit telecommunications approvals have been obtained for the following countries:
Note
The TS Module Modem is designed so that it can be used worldwide. Ensure compliance
with national laws and country-specific requirements when installing and operating the
TS Module Modem.
You can find the general technical specifications of the TS Module Modem in the section
Technical Specifications (Page 57).
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 29
TS module modem
5.4 Technical data of the TS Module modem
Modular TS Adapter
30 Manual, 06/2011, A5E02615140-02
TS Module ISDN 6
6.1 Scope of delivery and replacement parts of the TS Module ISDN
Product package
Spare parts
Please order the spare parts from your local Siemens representative.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 31
TS Module ISDN
6.2 Properties of the TS module ISDN
Properties
The TS Module ISDN has an internal terminal adapter with an S0 interface.
The S0 port is the 8-pin RJ45 socket behind the lower front panel. See the image in the
chapter LED display of the TS Module ISDN (Page 34)
Modular TS Adapter
32 Manual, 06/2011, A5E02615140-02
TS Module ISDN
6.2 Properties of the TS module ISDN
P
5- 5-
Note
How to connect the RJ45 connector:
1. Grasp the cable just below the RJ45 connector.
2. Make sure the RJ45 connector engages audibly.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 33
TS Module ISDN
6.3 LED display of the TS Module ISDN
Overview
The following image shows the LEDs on the front side of the TS Module ISDN. The LEDs,
DCD, RxD and TxD are located behind the upper front panel. The TS Module ISDN is
illustrated in the image without front panels.
Modular TS Adapter
34 Manual, 06/2011, A5E02615140-02
TS Module ISDN
6.3 LED display of the TS Module ISDN
Start-up characteristics
The LED ON is switched on when the power is restored.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 35
TS Module ISDN
6.4 Technical data of the TS Module ISDN
Specifications
● Dimensions: H 100 x L 30 x W 75 mm
● Weight: Approx. 92 g
● D-channel protocols DSS1 (Euro-ISDN), 1TR6
● Multiple subscriber number (MSN)
● Support of the most important B-channel-protocols:
– V.110 (9600 bit/s, 19200 bit/s, 38400 bit/s)
– V.120 (64 Kbit/s)
– X.75 (64 Kbit/s)
● AT command interpreter
Country list
You will find the current list of countries online at:
http://www.siemens.com/automation/service&support
Procedure
Proceed as follows:
1. Select the entry "Product support".
2. In product support, look for the term "TS Adapter IE Basic" or "TS Module ISDN".
3. Select the "List of contributions" tab.
4. Enter "Certificates" in the "Contribution type" selection box.
Modular TS Adapter
36 Manual, 06/2011, A5E02615140-02
TS Module ISDN
6.4 Technical data of the TS Module ISDN
Explicit telecommunications approvals have been obtained for the following countries:
Note
Ensure compliance with national laws and country-specific requirements when installing and
operating the TS Module ISDN.
You can find the general technical specifications of the TS Module ISDN in the section
Technical Specifications (Page 57).
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 37
TS Module ISDN
6.4 Technical data of the TS Module ISDN
Modular TS Adapter
38 Manual, 06/2011, A5E02615140-02
TS Module RS232 7
7.1 Scope of deliver of the TS module RS232
Product package
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 39
TS Module RS232
7.2 Properties of the TS module RS232
Properties
The TS Module RS232 has a COM interface that serves exclusively for the connection of the
external modem.
The COM interface, a 9-pin RS232 plug connector, is located behind the lower front panel.
See the image in the chapter LED display of the TS Module RS232 (Page 43).
You can operate the following devices from the COM port:
● Standard modems
● ISDN terminal adapters
● GSM wireless modems with an RS232 port
NOTICE
The specifications relating to interference immunity and interference emission apply only
when using devices, lines and connectors conforming to industrial requirements in
accordance with EN 61000-6-4:2001 and EN 61000-6-2:2001.
Modular TS Adapter
40 Manual, 06/2011, A5E02615140-02
TS Module RS232
7.2 Properties of the TS module RS232
Note
Sub D connector design
Please observe the maximum plug dimensions specified in the following image.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 41
TS Module RS232
7.2 Properties of the TS module RS232
P
P
Modular TS Adapter
42 Manual, 06/2011, A5E02615140-02
TS Module RS232
7.3 LED display of the TS Module RS232
Overview
The following figure shows the front side of the TS Module RS232 without front covers.
The TS Module RS232 doe snot have any other LED displays. The statuses of the DCD,
RxD and TxD signals are displayed in the connected modem.
Start-up characteristics
The LED ON is switched on when the power is restored.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 43
TS Module RS232
7.4 Technical data of the TS Module RS232
Specifications
● Dimensions: H 100 x L 30 x W 75 mm
● Weight: Approx. 100 g
● Operating mode: Full duplex, asynchronous
● Signals: TXD, RXD, DSR, CTS, RTS, DTR, DCD
● Data transmission rate: 2400...115 200 bit/s
● Telegram: 8 data bits (LSB first), no parity bit, 1 stop bit
● Rule: according to RS232 standard
● Connectors: D-sub 9-pin, male (PC COMx)
You can find the general technical specifications of the TS Module RS232 in the section
Technical Specifications (Page 57).
Modular TS Adapter
44 Manual, 06/2011, A5E02615140-02
TS Module GSM 8
8.1 Scope of delivery and accessories for the TS Module GSM
Note
The device is designed for industrial use.
Product package
Accessories
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 45
TS Module GSM
8.2 Properties of the TS module GSM
Properties
The TS Module GSM has a port for the connection of a GSM/GPRS antenna and a slot for a
SIM card..
The antenna connection and the slot for the SIM card are located behind the lower front
panel. Refer to the image in the LED display of the TS Module GSM (Page 50).
Modular TS Adapter
46 Manual, 06/2011, A5E02615140-02
TS Module GSM
8.3 Activation of the SIM card for a CSD data connection
Note
As a rule, the network provider allocates a separate number (data number) for the CSD data
connection.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 47
TS Module GSM
8.4 SIM card installation
NOTICE
The SIM card may only be removed or inserted if the TS Module GSM is de-energized.
Modular TS Adapter
48 Manual, 06/2011, A5E02615140-02
TS Module GSM
8.4 SIM card installation
2. Place the SIM card in the SIM card tray as shown and put the SIM card tray back into its
slot.
1
2
① GSM module
② SIM card
③ SIM card tray
Figure 8-3 SIM card installation
Note
Ensure that the SIM card tray is inserted in the guide intended in precisely the right
mounting position. If this is not done, the SIM card will not have the right contact and the
SIM card tray can no longer be removed using the eject button.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 49
TS Module GSM
8.5 LED display of the TS Module GSM
Overview
The following image shows the LEDs on the front side of the TS Module GSM. The
CONNECTED and SIGNAL QUALITY LEDs are behind the top front flap. The
TS Module GSM is illustrated in the image without the upper front panels.
Start-up characteristics
The LEDs are first activated after the initialization and are thus turned on a few seconds later
corresponding to the current operating state.
Modular TS Adapter
50 Manual, 06/2011, A5E02615140-02
TS Module GSM
8.5 LED display of the TS Module GSM
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 51
TS Module GSM
8.6 Technical data of the TS Module GSM
Specifications
● Dimensions: H 100 x L 30 x W 75 mm
● Weight: Approx. 118 g
● Speed
– GPRS Multislot Class 10:
– Up to 2 uplinks: GPRS: 13.4 kBit/s - 27 kBit/s Upload gross
– Up to 4 downlinks: GPRS: 40 kBit/s - 54 kBit/s download gross
● Interfaces
– SIM interface: 3 V / 1.8 V
– Antenna connector: 1 x SMA antenna socket (50 Ohm)
● Frequency area; quad band: 850, 900, 1800, 1900 MHz
● Transmit output power:
– 2 W at 850, 900 MHz
– 1 W at 1800, 1900 MHz
Standards
The TS Module GSM satisfies the requirements of the following standards:
Modular TS Adapter
52 Manual, 06/2011, A5E02615140-02
TS Module GSM
8.6 Technical data of the TS Module GSM
Country list
Explicit telecommunications approvals have been obtained for the following countries:
NOTICE
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 53
TS Module GSM
8.6 Technical data of the TS Module GSM
Note
Ensure compliance with national laws and country-specific requirements when installing
and operating the TS Module GSM.
You can find the general technical specifications of the TS Module GSM in the section
Technical Specifications.
Safety information
Note
Take the following safety notes into account:
• Radio
Never use the unit in areas in which the operation of radio equipment is not permitted.
The device contains a radio transmitter, which can hinder electronic devices like hearing
aids or pacemakers. Your doctor or the manufacturer of such devices can give you
information about this. IN order to make sure that no data carriers are demagnetized,
please do not store any discs, credit cards or other magnetic data carriers near the
device.
• Antenna assembly
The compliance with the recommended radiation thresholds of the Radiological
Protection Commission from September 13/14, 2001, must be guaranteed.
• Assembly of an exterior antenna
With the installation of an antenna outdoors, it is necessary that the antenna is properly
installed by a professional. The compliance with the lightning protection standard VDE V
0185 part 1 to 4 in its current edition and further standards are prescribed here.
• The building lightning protection class (SK)
With an outdoor installation, the antenna may only be installed within the lightning
protection zones O/E and 1. These lightning protection zones are predefined through the
lightning protection ball radius.
• The EMV lightning protection zones concept
The EMV lightning protection zones concept must be complied with. In order to avoid
large induction loops, a lightning protection potential compensation must be used. If the
antenna or the antenna cable is installed near the lightning protection system, the
minimum clearance to the lightning protection system must be complied with. If this is not
possible, an insulated assembly is required as described in the lightning protection
standard VDE V 0185 part 1 to 4 in its current edition.
Modular TS Adapter
54 Manual, 06/2011, A5E02615140-02
TS Module GSM
8.6 Technical data of the TS Module GSM
NOTICE
Ensure compliance with national laws and country-specific requirements when installing
and operating the TS Module GSM.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 55
TS Module GSM
8.6 Technical data of the TS Module GSM
Modular TS Adapter
56 Manual, 06/2011, A5E02615140-02
Technical data 9
9.1 General Specifications
Modular TS Adapter
Power supply Through the internal voltage of the TS Adapter IE Basic.
;;
;;
;;
;;
;; 36 &38 ;;;;;;;;;; ;;;;
;;
;;
&38
36
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 57
Technical data
9.2 Electromagnetic Compatibility
Definition of "EMC"
Electromagnetic Compatibility (EMC) defines the capability of electrical equipment to
operation satisfactorily in its electromagnetic environment without influencing this
environment.
WARNING
NOTICE
The specifications relating to interference immunity and interference emission apply only
when using devices, lines and connectors conforming to industrial requirements in
accordance with EN 61000-6-4:2007 and EN 61000-6-2:2005.
Pulsed interference
The table below shows the electromagnetic compatibility of the modular TS Adapter in
relation to pulsed interference. This requires that the electrical installation to comply with
relevant specifications and standards.
Modular TS Adapter
58 Manual, 06/2011, A5E02615140-02
Technical data
9.2 Electromagnetic Compatibility
Sinusoidal interference
The table below shows the electromagnetic compatibility of the modular TS Adapter in
relation to sinusoidal interference.
Additional measures
If you wish to operate the modular TS Adapter in an office area, you must implement
additional measures to meet the requirements of EN 61000-6-3.
Take suitable additional measures if you need to increase the interference immunity of the
system due to high external interference levels.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 59
Technical data
9.3 Transportation and Storage Conditions
Permitted range
Temperature -40 to +70° C
Barometric pressure 1080 to 660 hPa (corresponding to an altitude of -1000 to
3500 m)
Relative humidity (at +25° C) 5 to 95%, without condensation
Sinusoidal vibration to IEC 60068-2-6 5 - 9 Hz: 3.5 mm
9 - 500 Hz: 9.8 m/s2
Shock impact to IEC 60068-2-29 250 m/s2, 6 ms, 1000 shocks
Modular TS Adapter
60 Manual, 06/2011, A5E02615140-02
Technical data
9.4 Mechanical and climatic environmental conditions
Operating conditions
The modular TS Adapter is designed for weather-protected, stationary use. The modular
TS Adapter complies with the operational requirements to DIN IEC 60721-3-3:
● Class 3M3 (mechanical requirements)
● Class 3K3 (climatic ambient conditions)
Reduction of vibration
Where the modular TS Adapter is subject to major shock impact or vibration, you must take
suitable measures in order to reduce the acceleration or amplitude.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 61
Technical data
9.4 Mechanical and climatic environmental conditions
Modular TS Adapter
62 Manual, 06/2011, A5E02615140-02
Technical data
9.5 Specifications for insulation, safety class, and degree of protection
Insulation requirements
The TS Adapter IE Basic with TS Module Modem can also be used in TNV-3 networks. The
separation between the telephone side and the rest of the electronics was checked during
the type test according to the requirements set forth in the IEC/EN 60950-1 and UL 60950-1
standards.
The ISDN interface was checked according to the IEC/EN 60950-1 standard with
TS Module ISDN.
All other galvanic isolations were designed to meet the requirements of IEC/EN 61131-2.
Protection class
The modular TS Adapter meets protection class III according to EN 61140:2002
(VDE 0140-1).
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 63
Technical data
9.6 Standards, Approvals, Certificates, Guidelines, Labels and Declarations
Note
The currently valid approvals are to be found on the product rating plate.
Safety requirements
● The modular TS Adapter meets the requirements and criteria of the IEC/EN 61131-2
standard.
● The IT interface is subject to the IEC 60950 standard (TS Module Modem /
TS Module ISDN).
CE mark
Our products conform to the requirements and safety objectives of the EC Directives listed
below. They are compliant with the harmonized European Standards (EN) for programmable
logic controllers as published in the official gazettes of the European Community:
● TS Module RS232
2004/108/EC "Electromagnetic Compatibility" (EMC Directive)
● 94/9/EC "Equipment and protective systems intended for use in potentially explosive
atmospheres" (Explosion Protection Directive)
● 1999/5/EC "Radio and telecommunications terminal equipment" (RTTE Directive)
(TS Module Modem / TS Module ISDN / TS Module GSM)
The EC declaration of conformity is held on file available to competent authorities at:
Siemens Aktiengesellschaft
Industry Sector
I IA AS RD ST Typetest
P.O. Box 1963
D-92209 Amberg
EMC Directive
For the TS Module RS232 , the following guidelines apply:
Modular TS Adapter
64 Manual, 06/2011, A5E02615140-02
Technical data
9.6 Standards, Approvals, Certificates, Guidelines, Labels and Declarations
RTTE Directive
The following guidelines apply to Module Modem, TS Module ISDN und TS Module GSM:
● Safety: Telecommunications interface tested to EN 60950-1:2006 + A11:2009
● EMC:
Network compatibility
● TS Module ISDN: TBR3
● TS Module Modem:
– ETSI ES 203021 V2.1.1
Part 1 General aspects, August 2005
Part 2 Basic transmission and protection of the network from harm, August 2005
Part 3 Basic Interworking with the Public Telephone Networks, August 2005
– ETSI ES 201787 V1.1.1
Loop Disconnect (LD) dialling specific requirements
– ETSI ES 201729 V1.1.1
Timed break recall (register recall)
Note
Which of the following approvals has been issued in respect of your product is indicated by
the markings on the rating plate.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 65
Technical data
9.6 Standards, Approvals, Certificates, Guidelines, Labels and Declarations
cULus approval
Note
The system installation must be compliant with NEC (National Electric Code)
requirements.
For use in Class I, Division 2 environments, the modular TS Adapter must be installed in
a cubicle with minimum IP54 protection to IEC 60529.
Information on use of the modular TS Adapter in Zone 2 hazardous areas is contained in
the "Product Information ATEX Zone 2.pdf" file.
located on the product CD in the "_Product_Information" folder.
WARNING
Explosion Hazard - Do not disconnect while circuit is live unless area is known to be
non-hazardous.
Explosion Hazard - Substitution of components may impair suitability for Class I,
Division 2 or Class I, Zone 2.
Modular TS Adapter
66 Manual, 06/2011, A5E02615140-02
Technical data
9.6 Standards, Approvals, Certificates, Guidelines, Labels and Declarations
FM approval
WARNING
Connecting peripherals
Interference immunity requirements are met when connected to an industrial standard
PC/modem in accordance with EN61000-6-2:2005.
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 67
Technical data
9.6 Standards, Approvals, Certificates, Guidelines, Labels and Declarations
EU approval
The TS Adapter IE Basic in connection with the TS Module Modem /TS Module ISDN /
TS Module GSM has been approved in accordance with Council Decision 98/4827EG for
pan-European single terminal connection to the public switched telephone network.
However, due to differences between the individual PSTNs provided in different countries
the approval does not, of itself, give an unconditional assurance of successful operation on
every PSTN network termination point.
Modular TS Adapter
68 Manual, 06/2011, A5E02615140-02
Technical data
9.7 Customer Information for ACTA
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 69
Technical data
9.7 Customer Information for ACTA
Note
Disruptions of the alarm functions of alarm equipment may occur not only as a result of faulty
installation, but also in situations where the TS Module Modem is used as intended (dual
channel mode).
Canada
IC: 4030A-081TSMM
This product meets the applicable Industry Canada technical specifications.
The Ringer Equivalence Number (REN=0.4) is an indication of the maximum number of
devices allowed to be connected to a telephone interface. The termination of an interface
may consist of any combination of devices subject only to the requirement that the sum of
the RENs of all the devices not exceed five.
Modular TS Adapter
70 Manual, 06/2011, A5E02615140-02
Technical data
9.8 Technical Support
Technical support
How to contact Technical Support for all Industry Automation products
● Using the web form to request support
http://www.siemens.com/automation/support-request
Additional information about Siemens Technical Support is available on the Internet at
http://www.siemens.com/automation/service&support
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 71
Technical data
9.8 Technical Support
Additional support
If you have any questions about using the products described in the manual and do not find
the correct answers in this document, please contact your Siemens representative at your
local Siemens office.
You can find your local partner at:
http://www.siemens.com/automation/partner
A guide to our technical documentation for the various SIMATIC products and systems is
available at:
http://www.siemens.com/simatic-doku
The online catalog and online ordering systems are available at:
http://www.siemens.com/automation/mall
Training Centers
Siemens offers corresponding courses to get you started with the SIMATIC S7 automation
system. Please contact your regional training center or the central training center in
90327 Nuremberg, Germany.
http://www.siemens.com/sitrain
Modular TS Adapter
72 Manual, 06/2011, A5E02615140-02
Index
L
A LED statuses
Ambient conditions, 61 TS Module GSM, 51
Analog modem port, 25 TS Module ISDN, 35
Analog phone cable, 25 TS module modem, 28
Approvals, 64 TS Module RS232, 43
C M
CE mark, 64 Marking for Australia and New Zealand, 65
Climatic ambient conditions, 62 Mechanical ambient conditions, 61
cULus approval, 66 Minimum clearances, 18
Customer Information, 69 Mounting
in a casing, 18
on DIN rail, 15
E on profile rail, 13
Wall mounting, 17
Electromagnetic compatibility, 58 Mounting methods, 12
EMC Directive, 64
EU approval, 68
Explosion Protection Directive, 65 O
Operating conditions, 61
F
FM approval, 67 P
Pin assignment
H Analog modem port, 25
ISDN port, 33
Hardware requirements, 9 RS232 interface, 41
Protection class, 63
I
Installation R
horizontal, 57 Requirements
vertical, 57 Hardware, 9
ISDN phone cable, 33 RS232 interface, 41
ISDN port, 33 RTTE Directive, 65
S
Safety requirements, 67
Storage conditions, 60
Modular TS Adapter
Manual, 06/2011, A5E02615140-02 73
Index
T
Test voltage, 63
Transportation conditions, 60
TS Module GSM
Accessories, 45
Approvals, 53
CSD data connection, 47
LED statuses, 51
Product package, 45
Specifications, 52
TS Module ISDN
Approvals, 37
LED statuses, 35
Pin assignment, 33
Product package, 31
Spare parts, 31
TS module modem
Approvals, 29
LED statuses, 28
Pin assignment, 25
Product package, 23
Spare parts, 23
TS Module RS232
LED statuses, 43
Pin assignment, 41
Product package, 39
Specifications, 44
U
UL requirements
Installation requirements, 9
Phone cable, 9
Modular TS Adapter
74 Manual, 06/2011, A5E02615140-02