MID 036 - CID 0336 - FMI 02 Incorrect ECS Switch Inputs: Cerrar SIS Pantalla Anterior

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

3516B Marine Engine S2X00001-UP(SEBP3924 - 42) - Documentación Page 1 of 1

Cerrar SIS

Pantalla anterior

Producto:  MARINE ENGINE 
Modelo:  3516B MARINE ENGINE S2X 
Configuración: 3516B Marine Engine S2X00001-UP 

Localización y Solución de Problemas


3500B and 3500C Marine Propulsion Engines
Número de medio -RENR5009-07 Fecha de publicación -01/08/2010 Fecha de actualización -26/08/2010

i01954884

MID 036 - CID 0336 - FMI 02 Incorrect ECS Switch inputs


SMCS - 1901-038

Conditions Which Generate This Code:

One line for the Engine Control Switch (ECS) is open and one line is low.

System Response:

The CID-FMI is logged in memory. The Electronic Control Module (ECM) will flag the ignition
switch as invalid data.

Test Step 1. Perform the following diagnostic procedure: Engine Control Switch (ECS)

Results:

• OK - STOP

• REPAIRED, OK - STOP