MOSEB VPEMF Series Electromagnetic Flow Meter
MOSEB VPEMF Series Electromagnetic Flow Meter
MOSEB VPEMF Series Electromagnetic Flow Meter
GENERAL
The VPEMF series electromagtic flow meter is a kind of flow
meter made by adopting Faraday law of electromagnetic
induction.
STANDARD SPECIFICATION
Size : 3mm(1/8”)~3000mm(120”) Local Display : LCD Display With Back Light
Measuring Range : Liquid - 0.003 ~ 382,000 m3/Hr Digit Display : 5 Digit Flowrate
Flow Velocity : 0.1m/s ~ 15m/s : 8 Digit Totalizer
Conductivity : Over 5 ㎲ / ㎝ Output
Accuracy : Analog : DC 4 - 20mA/ 0-10mA
DN15 ~ DN600 ±0.3% of the indicating value (flow velocity Pulse : Passive Output (0-5000HZ)
≥1m/s); ±3mm/s (flow velocity <1m/s)
Alarm : 2 Points (high/low flow rate)
DN3 ~ DN10 ±0.5% of the indicating value (flow velocity
DN700 ~ DN3000 ≥0.8m/s); ±4mm/s (flow velocity <0.8m/s) Communication Protocol :RS232/RS485/Hart/Profibus DP
Material Flowrate Unit : Ltr, ft3,m3, Igal, Ugal
Measuring Tube : Stainless Steel 304,316 Flow Time Unit : S, Min, Hr,Dy, Wk
Lining : PTFE, Neoprene ,PFA,F46,PU,Ceramic Flow velocity Unit : m/s
Electrode : SS 316L, Hastelloy-B/C,Titanium,Tantalum, Platinum Power Supply : 19 ~ 40V D.C.
Flange : C S , SS 304, SS316, SS 316L : 85 ~ 265V A.C. 45 ~ 400HZ
Fluid Temperature Ambient Temperature : -40 to +60 °C
Compact Type : -40 ~ +70 °C (Standard) Protection Class : PI 65, IP 67, IP 68
: -40 ~ +60 °C (Explosion Proof) Explosion Proof : Exdibmb II CT6 (Circular Converter)
Remote Type : -40 ~ +150 °C (Standard) : Exdibmb II B+H2T6 (Square Converter)
: -40 ~ +80 °C (Explosion Proof) Power Consumption : Less-than 20 VA
Process Connection Exciting Mode : Low-frequency Rectangular Wave
Flange Type : DIN PN 10 - PN 420 Exciting current : 125~500mA
: ANSI 150# - ANSI2500# Converter Housing : Aluminum Alloy
: JIS 10K / JIS 20K / JIS 40K/JIS63K Cable Entry : Standard : M20 M18
Other Option : Threaded, Clamp on,Tri-clamp Option : 1/2" NPT
FLOW RANGE - Flow Velocity
Size mm
Accuracy %
VE-PURE Malaysia
Page 2
DIMENSIONS & PARAMETERS
Material
No. Description
Normal Option
Connecting
2 C. S. S.S 304/S.S 316
base
Measuring
4 S.S 304 S.S 316
tube
Threaded
M 2 0 × 1 . Connection(F)
5深 10
26 0
1 50 86
DN3, DN6, DN10 Threaded Type Sensor Dimensions(Normal) Larger Caliber Is Optional
VE-PURE Malaysia
Page 3
DIMENSIONS
E-mag
开 封仪 表 厂
VE-PURE Malaysia
Page 4
DIMENSIONS
VE-PURE Malaysia
Page 5
DIMENSIONS
SIZE L D H Weight
mm (kg)
15 80 76 180 10
20 80 76 180 12
25 100 82 185 14
32 110 98 200 15
40 120 104 205 16
VE-PURE Malaysia
Page 6
VE-PURE VPEMF Series Electromagnetic Flow Meter
VE-PURE Malaysia
Page 7