Water Measurement Manual
Water Measurement Manual
Water Measurement Manual
Bureau of Reclamation
In cooperation with
FIRST EDITION 1953 SECOND EDITION 1967 REPRINTED 1967, 1971 REVISED REPRINT 1974 REPRINTED 1975, 1977, 1981 REVISED REPRINT 1984 REPRINTED 1993 THIRD EDITION 1997 REVISED REPRINTED 2001
For sale by the Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402. As the Nation's principal conservation agency, the Department of the Interior has responsibility for most of our nationally owned public lands and natural resources. This includes fostering sound use of our land and water resources; protecting our fish, wildlife, and biological diversity; preserving the environmental and cultural values of our national parks and historical places; and providing for the enjoyment of life through outdoor recreation. The Department assesses our energy and mineral resources and works to ensure that their development is in the best interests of all our people by encouraging stewardship and citizen participation in their care. The Department also has a major responsibility for American Indian reservation communities and for people who live in island territories under U.S. Administration.
PREFACE
The mission of many public and private water resources organizations is to manage and conserve existing water supplies. These management efforts involve making sound technical and economic decisions concerning new and existing water needs, while respecting the environment by sustaining or restoring the aquatic ecosystems which may be affected. One key to better management practices, including water conservation, is reliable and accurate water measurement. The term "water measurement" as used in this manual refers to the measurement of flow (unit volume per unit time). Major advances in measurement technology along with a continued demand for the Water Measurement Manual are responsible for initiating this revision. The first edition of the Water Measurement Manual (1953) had a distribution of 11,000 copies and was compiled from the Bureau of Reclamation (Reclamation) publication Manual for Measurement of Irrigation Water (1946). This previous manual had five earlier editions beginning in 1913 and extending to 1940. The continual demand for the Water Measurement Manual and the need for updating resulted in the second edition (1967). From 1967 to 1984, two revised reprints plus five reprints of the second edition were published. The demand and need for the second edition has continued because of conservation pressure and increased user competition for water; therefore, this third edition was prepared to supplement and update information contained in the second edition. Modern trends of technical practice, along with the developments in personal computers, have resulted in increased emphasis on using custom-fitted, long-throated measurement structures that can be designed to measure flow and are simpler to fabricate. Consequently, fewer short-form flumes are being considered for new installations. Thus, information on Parshall flumes has been reduced and incorporated in the more general "Flumes" chapter, which recommends longthroated flumes for new installation in preference to Parshall flumes. The main Parshall flume information retained in this edition relates to maintenance and operation needs of existing flumes, including flume dimensions, free flow measurement, submerged flow measurement, and head losses. The sections on size selection and setting crest elevation for Parshall flumes have been deleted or reduced in this edition. Where Parshall flumes may be desired or required by State law, examples in the previous editions of the manual can be referred to for size selection and setting the crest elevation. New chapters and sections were added to make the third edition more current technologically and more useful to other government organizations. The new chapters added are:
Basic Concepts Related to Flowing Water and Measurement Selection of Water Measuring Devices Measurement Accuracy Inspection of Water Measurement Systems Acoustic Flow Measurement Discharge Measurement Using Tracers i.
Russ Dodge was the primary author/editor for the revisions in this third edition. Reclamation especially appreciates the efforts of John Replogle and Albert Clemmens (from the U.S. Water Conservation Laboratory) of the Agricultural Research Service for writing major portions of chapters or separate sections relating to selection of devices, long-throated flumes, overshot weirs, and other devices, as well as for reviewing revisions of the entire manual. Reclamation is also indebted to the U.S. Natural Resources Conservation Service, formerly the Soil Conservation Service, for contribution of material and reviews by Leland Hardy and Thomas Spofford. In addition to personnel from outside organizations, several Reclamation personnel contributed to revisions of new sections and chapters. Warren Frizell revised the chapter on measuring and recording water stage or head and conducted a peer review of the manual. Tracy Vermeyen wrote the chapter on acoustic flow measurements. Brent Mefford wrote much of the chapter on selection of water measurement devices. Dave Rogers wrote the section on radial gate flow measurements and the use of the RADGAT computer program. Tony Wahl compiled the tables in appendix A. Cliff Pugh coordinated the assembly, reviews, and publication. Jerry Fitzwater assembled and modified many of the drawings and figures. Tom Hovland was the primary technical editor in charge of publication editing and organization, and Teri Manross did the desktop publishing and copy editing. Jim Higgs created the online version of the manual, which is available at www.usbr.gov/pmts/hydraulics_lab/pubs/wmm/ Certain trade names appear in the manual. Mention of such names should not be construed as an endorsement or recommendation of a product by the Bureau of Reclamation, Agricultural Research Service, or Natural Resource Conservation Service.
ii.
Accurate accounting and good records help allocate equitable shares of water between competitive uses both on and off the farm. Good water measurement practices facilitate accurate and equitable distribution of water within district or farm, resulting in fewer problems and easier operation. Accurate water measurement provides the on-farm irrigation decision-maker with the information needed to achieve the best use of the irrigation water applied while typically minimizing negative environmental impacts. Installing canal flow measuring structures reduces the need for time-consuming current metering. Without these structures, current metering is frequently needed after making changes of delivery and to make seasonal corrections for changes of boundary resistance caused by weed growths or changes of sectional shape by bank slumping and sediment deposits. Instituting accurate and convenient water measurement methods improves the evaluation of seepage losses in unlined channels. Thus, better determinations of the cost benefits of proposed canal and ditch improvements are possible. Permanent water measurement devices can also form the basis for future improvements, such as remote flow monitoring and canal operation automation. 1-1
Good water measurement and management practice prevents excess runoff and deep percolation, which can damage crops, pollute ground water with chemicals and pesticides, and result in project farm drainage flows containing contaminants. Accounting for individual water use combined with pricing policies that penalize excessive use.
3. Scope
This revised manual has three principal purposes. The first is to provide water users and districts guidance in selecting, managing, inspecting, and maintaining their water measurement devices. The second is to describe the standard methods and devices commonly used to measure irrigation water. The third is to acquaint irrigation system operators with a variety of other established but less common methods and with new or special techniques.
1-2
5. Bibliography
American Society of Mechanical Engineers, "Fluid Meters, Their Theory and Application," H.S. Bean, ed., Research Committee on Fluid Meters, sixth edition revised, New York, 1983. American Society of Mechanical Engineers, "Performance Test Codes-Hydraulic Turbines and Turbine Mode of Pump/Turbines," revision, Performance Test Code Committee No. 18, New York, 1992. Bos, M.G. (ed.), Discharge Measurement Structures, 3rd edition, International Institute for Land Reclamation and Improvement, Publication 20, Wageningen, The Netherlands, 1989. Bos, M.G., J.A. Replogle, and A.J. Clemmens, 1991, Flow Measuring Flumes for Open Channel Systems, John Wiley & Sons, 1984, and American Society of Agricultural Engineers, New York, 1991. Brakensiek, D.L., H.B. Osborn, and W.R. Rawls (coordinators/editors), Field Manual for Research in Agricultural Hydrology, Agricultural Handbook 224, U.S. Department of Agriculture, U.S. Government Printing Office, Washington, DC, 1979. Clemmens, A.J., M.G. Bos, and J.A. Replogle, "FLUME: Design and Calibration of LongThroated Measuring Flumes," version 3.0, International Institute for Land Reclamation and Improvement, Publication 54 (with software), The Netherlands, 1993. International Organization for Standardization, "Liquid Flow Measurement in Open Channels Using Weirs and Flumes," ISO 1438, Geneva, Switzerland, 1975. International Organization for Standardization, "Measurement of Liquid Flow in Open Channels," Handbook No. 15, Geneva, Switzerland, 1983. International Organization for Standardization, "Measurement of Flow by Means of Pressure Differential Devices," ISO 5167-1, Geneva, Switzerland, 1991. U.S. Geological Survey, National Handbook of Recommended Methods of Water-Data Acquisition," prepared cooperatively by U.S. Government agencies, Government Printing Office, Washington, DC, 1980.
1-3
2. Kinds of Flow
Flow is classified into open channel flow and closed conduit flow. Open channel flow conditions occur whenever the flowing stream has a free or unconstrained surface that is open to the atmosphere. Flows in canals or in vented pipelines which are not flowing full are typical examples. The presence of the free water surface prevents transmission of pressure from one end of the conveyance channel to another as in fully flowing pipelines. Thus, in open channels, the only force that can cause flow is the force of gravity on the fluid. As a result, with steady uniform flow under free discharge conditions, a progressive fall or decrease in the water surface elevation always occurs as the flow moves downstream. In hydraulics, a pipe is any closed conduit that carries water under pressure. The filled conduit may be square, rectangular, or any other shape, but is usually round. If flow is occurring in a conduit but does not completely fill it, the flow is not considered pipe or closed conduit flow, but is classified as open channel flow. Flow occurs in a pipeline when a pressure or head difference exists between ends. The rate or discharge that occurs depends mainly upon (1) the amount of pressure or head difference that exists from the inlet to the outlet; (2) the friction or resistance to flow caused by pipe length, pipe roughness, bends, restrictions, changes in conduit shape and size, and the nature of the fluid flowing; and (3) the cross-sectional area of the pipe. 2-1
2-2
The pressure force, Fp, on the tap connection area is designated pa. The weight and pressure force are equal, and dividing both by the area, a, gives the unit pressure on the wall of the pipe in terms of head, h, written as: p = h (2-1) or:
h=
(2-2)
Thus, head is pressure, p, divided by unit weight of water, , or 62.4 pounds per cubic foot (lb/ft3). Pressure is often expressed in psi or pounds per square inch (lb/in2), which may be converted to feet of water by multiplying the (lb/in2) value by 2.31. For example, 30 lb/in2 is produced by 69.3 feet of water. When the head principle is used, the discharge, Q, is computed from an equation such as the one used for a sharp-crested rectangular weir of length, L: Q = CLh3/2 (2-3) A coefficient, C, is included that accounts for simplifying assumptions and other deficiencies in deriving the equation. The coefficient can vary widely in nonstandard installations, but is well defined for standard installations or is constant over a specified range of discharge. The flow cross-sectional area, A, does not appear directly in the equation, but an area can be extracted by rewriting this equation: Q = CLhh1/2 (2-4) in which: A = Lh (2-5) In this form, C also contains a hidden square root of 2g, which, when multiplied by (h)1/2, is the theoretical velocity. This velocity does not need to be directly measured or sensed. Because the weir equation computes velocity from a measuring head, a weir is classified as a head measuring device. Some devices that actually sample or sense velocities, v, are: (1) Float and stopwatch (2) Current and propeller meters (3) Vane deflection meters These devices generally do not measure the average velocity, V, for an entire flow cross section. Thus, the relationship between sampled velocities, v, and the mean velocity, V, must be known as well as the flow section area, A, to which the mean velocity applies. Then, the discharge, Q, sometimes called the flow rate, is the product, AV. 2-3
Discharge or rate of flow has units of volume divided by unit time. Thus, discharge can be accurately determined by measuring the time, t, to fill a known volume, Vo: Q=
Vo (2-6) t
Water measurement devices can be calibrated using very accurate volumetric tanks and clocks. More commonly, weight of water in the tanks is used by converting the weight of water per unit volume. The weight of water per cubic foot, called unit weight or specific weight, , is 62.4 lb/ft3 at standard atmospheric conditions.
4. Discharge-Area-Velocity Relationships
Flow rate or discharge, Q, is the volume of water in cubic feet passing a flow section per unit time, usually measured in cubic feet per second (ft3/s). The distance, dv, in feet that water will travel at a given velocity in a pipe of constant diameter is velocity, V, in feet per second (ft/s) multiplied by time, t, in seconds, or: dv = Vt (2-7) The volume, Vo, in cubic feet passing from the upstream to the downstream ends of this distance is the distance, dv, in feet times area, A, in square feet of the flow section. Thus: Vo = dvA = AVt (2-8) To get the time rate of flow or discharge, Q, in cubic feet per second, divide the right and left sides of equation 2-8 by time, t, in seconds, resulting in: Q = AV (2-9) Flow in open channels of rectangular cross section is often expressed in terms of unit discharge, q, in cubic feet per second per foot of width which is discharge, Q, in cubic feet per second divided by cross-sectional width, Lb, in feet or: q=
Q VA = = VD (2-10) Lb Lb
The area, A, is LbD, where D is the depth of flow. The continuity concept is an important extension of equation 2-9. On the basis that water is incompressible and none is lost from a flowing system, then as the cross-sectional area changes, the velocity must adjust itself such that the values of Q or VA are constant: Q = A1V1 = A2V2 = . = AnVn (2-11)
2-4
where the subscript denotes any number of arbitrarily selected positions along the flowing system. This principle, known as continuity, is especially useful in the analysis of tube flow measurement devices such as the venturi meter.
5. Flow Totalization
Water is sold and measured in terms of total volume consumed, say cubic feet, over some convenient time period, perhaps for billing each month. Many flowmeters have built in capability to sum or totalize volume continually. Thus, the volume consumed is obtained by taking the difference of two sequential monthly readings. To aid irrigation operation and management, most meters provide instantaneous rate of flow or discharge displayed in units such as cubic feet per second. These flow rates are used to set flow and predict the volume of water that will be consumed for intervals of time after flow setting.
8. Orifice Relationships
Equations 2-9 and 2-13 can be used to develop an equation for flow through an orifice, which is a sharp-edged hole in the side or bottom of a container of water (figure 2-2a). To find the velocity of flow in the orifice, use equation 2-13, then multiply by area to get AV, or discharge, Q, resulting in: Q1 = A 2 gh (2-14) The subscript t denotes theoretical discharge through an orifice. This equation assumes that the water is frictionless and is an ideal fluid. A correction must be made because water is not an ideal fluid. Most of the approaching flow has to curve toward the orifice opening. The water, after passing through the orifice, continues to contract or curve from the sharp orifice edge. If the orifice edges are sharp, the jet will appear as shown on figure 2-2. The maximum jet contraction occurs at a distance of one-half the orifice diameter (d/2) downstream from the sharp edge. The cross-sectional area of the jet is about six-tenths of the area of the orifice. Thus, equation 2-14 must be corrected using a contraction coefficient, Cc, to produce the actual discharge of water being delivered. Thus, the actual discharge equation is written as: Qa = Cc A 2 gh (2-15) For a sharp-edged rectangular slot orifice where full contraction occurs, the contraction coefficient is about 0.61, and the equation becomes: Qa = 0.61A 2 gh (2-16) A nonstandard installation will require further calibration tests to establish the proper contraction coefficient because the coefficient actually varies with the proximity to the orifice edge with respect to the approach and exit boundaries and approach velocity.
A correction factor is needed to account for simplifications and assumptions. Thus, a discharge coefficient, Cd, is added to obtain actual discharge, expressed as: Q a = Cd
2 3
2 g Lbh3/2 (2-18)
This relationship is the basic weir equation and can be modified to account for weir blade shape and approach velocity. However, Cd must be determined by analysis and calibration tests. For standard weirs, Cd is well defined or constant for measuring within specified head ranges.
2-7
Figure 2-3c -- Specific energy balance. Figures 2-3a and 2-3b show the total energy head, H1; for example, at point 1, in a pipe and an open channel, which can be written as: V H1 = h1 + 1 + Z1 (2-19) 2g
2
V H2 = h2 + 2 + Z2 (2-20) 2g Energy has been lost because of friction between points 1 and 2, so the downstream point 2 has less energy than point 1. The energy balance is retained by adding a head loss, hf (1-2). The total energy balance is written as: h1 = V1 V + Z1 = h2 + 2 + Z2 + hf (1-2) (2-21) 2g 2g
2 2
The upper sloping line drawn between the total head elevations is the energy gradeline, egl. The next lower sloping solid line for both the pipe and open channel cases shown on figure 2-3 is the hydraulic grade line, hgl, which is also the water surface for open channel flow, or the height to which water would rise in piezometer taps for pipe flow. A special energy form is commonly used in hydraulics in which the channel invert is selected as the reference Z elevation (figure 2-3c). Thus, Z drops out, and energy is the sum of depth, h, and velocity head only. Energy above the invert expressed this way is called specific energy, E. This simplified form of energy equation is written as: Specific energy = E =
V2 + h (2-22) 2g
Equations 2-21 and 2-11 lead to several interesting conclusions. In a fairly short pipe that has little or insignificant friction loss, total energy at one point is essentially equal to the total energy at another point. If the size of the pipeline decreases from the first point to the second, the velocity of flow must increase from the first point to the second. This increase occurs because with steady flow, the quantity of flow passing any point in the completely filled pipeline remains the same. From the continuity equation (equation 2-11), when the flow area decreases, the flow velocity must increase. The second interesting point is that when the velocity increases in the smaller section of the pipeline, the pressure head, h, decreases. At first, this decrease may seem strange, but equation 221 shows that when V2/2g increases, h must decrease proportionately because the total energy from one point to another in the system remains constant, neglecting friction loss. The fact that the pressure does decrease when the velocity in a given system increases is the basis for tubetype flow measuring devices. In open channel flow where the flow accelerates, more of its supply of energy becomes velocity head, and depth must decrease. On the other hand, when the flow slows down, the depth must increase.
2-9 An example of accelerating flow with corresponding decreasing depth is found at the approach to weirs. The drop in the water surface is called drawdown. Another example occurs at the entrance to inverted siphons or conduits where the flow accelerates as it passes from the canal, through a
contracting transition, and into the siphon barrel. An example of decelerating flow with a rising water surface is found at the outlet of an inverted siphon, where the water loses velocity as it expands in a transition back into canal flow. Flumes are excellent examples of measuring devices that take advantage of the fact that changes in depth occur with changes in velocity. When water enters a flume, it accelerates in a converging section. The acceleration of the flow causes the water surface to drop a significant amount. This change in depth is directly related to the rate of flow.
A (2-23) Pw
Thus, wetted perimeter times the hydraulic radius is equal to the area of irregular section flow as shown on figures 2-4a and 2-4c. For use in Froude number and energy relationships in open channel flow hydraulics, mean depth, hm, is defined as the depth which, when multiplied by the top water surface width, T, is equal to the irregular section area, A, shown on figures 2-4a and 2-4b, of the flow section and is commonly used for critical flow relationships. The equation for hydraulic mean depth, hm, is: hm =
A (2-24) T
In rectangular channels, hydraulic radius, Rh, does not equal depth, but approaches depth as the channel becomes very wide. However, the hydraulic mean depth, hm, is the same as the depth of the rectangular flow section.
2-10
Figure 2-4 -- Definitions of hydraulic radius and hydraulic mean depth (area is the same for all three cases).
where the subscript m denotes hydraulic mean depth as defined previously in section 11 of this chapter. For open channel modeling, the Froude number of a model is made equal to the Froude number of the actual full size device. The length ratio is set and the scale ratios for velocity and discharge are determined from the equality. However, the modeler must make sure that differences in friction loss between the model and the actual device are insignificant or accounted for in some way.
2-11
Open channel flow water measurement generally requires that the Froude number, F, of the approach flow be less than 0.5 to prevent wave action that would hinder or possibly prevent an accurate head reading. When the Froude number is 1, the velocity is equal to the velocity of wave propagation, or celerity. When this condition is attained, downstream wave or pressure disturbances cannot travel upstream. A Froude number of 1 also defines a very special hydraulic condition. This flow condition is called critical and defines the critical mean depth and critical velocity relationship as: Fc = Vc ghcm (2-26)
The subscript c denotes critical flow condition. The critical hydraulic mean depth, hcm, is the depth at which total specific energy is minimum for a given discharge. Conversely, hcm is the depth at which the discharge is maximum for a given total specific energy. When depth is greater than critical, the resulting velocity is considered streaming or tranquil and is called subcritical velocity. Conversely, when the depth is less than critical, the flow is rapid or shooting and is called super-critical velocity. Water measurement flumes function best by forcing flow to pass through critical depth; then discharge can be measured using one head measurement station upstream. Also, for weirs and flumes, one unique head value exists for each discharge, simplifying calibration. This flow condition is called free flow. However, if the downstream depth submerges critical depth, then separate calibrations at many levels of submergence are required, and two head measurements are needed to measure flow. Designing flumes for submerged flow will always decrease accuracy of flow measurement. Flumes and weirs can be submerged unintentionally by poor design, construction errors, structural settling, attempts to supply increased delivery needs by increasing downstream heads, accumulated sediment deposits, or weed growths. Important critical flow relationships can be derived using equation 2-26 and rewriting in the form: Vc = ghcm (2-27) Solving for head in equation 2-27 results in: V hcm = c g
2
(2-28)
Dividing both sides of this equation by 2 gives critical velocity head in terms of critical mean depth written as:
2-12
h Vc = cm (2-29) 2 2g The total energy head with Z equal to zero for critical flow using equation 2-19 is: Hc = h c + Vc (2-30) 2g
2
Squaring both sides of equation 2-27 and replacing velocity with Q/A and hcm with A/T according to equation 2-24 and rearranging results in: Qc g
2
Ac Tc
(2-31)
This equation and the specific energy equation 2-22 are the basic critical flow relationships for any channel shape.
hc (2-32) 2
or: Hc = Conversely: hc =
3 hc (2-33) 2
2 Hc (2-34) 3
Multiplying both sides of equation 2-27 by the area, Ac, of the flow section, which is Lbhc, results in discharge expressed as: Q = Lbhc ghc = Lb ghc
3/2
(2-35)
To get unit discharge, q, this equation is divided by the width of flow, Lb, resulting in:
2-13
Q = ghc Lb
3/2
(2-36)
hc =
q2 (2-37) g
Using equation 2-34 to replace hc with Hc in equation 2-35 results in theoretical discharge, Qt:
2 Q1 = Lb g ( Hc )3/2 (2-38) 3
Discharges in equations 2-35 through 2-38 are usually considered actual, assuming uniform velocity throughout the critical depth cross section and assuming that no correction of velocity distribution is needed. Because specific energy is constant in a fairly short measuring structure with insignificant friction losses, specific energy, Hc, at the critical location can be replaced with specific energy, H1, at a head measuring station a short distance upstream. However, some friction loss, possible flow curvature, and non-uniform velocity distribution occur. Thus, a coefficient of Cd must be added to correct for these effects, resulting in an expression for actual discharge:
Q a = Cd L b
2 3
2 gH13/2 (2-39) 3
For measurement convenience, the total head, H1, is replaced with the depth, h1. To correct for neglecting the velocity head at the measuring station, a velocity coefficient, Cv, must be added, resulting in:
Q a = C d C vL b
2 3
2 gh13/2 (2-40) 3
This equation applies to both long-throated flumes or broad-crested weirs and can be modified for any shape by analyses using the energy balance with equation 2-31. These equations differ only in numerical constants that are derived from assumptions and selection of basic relationships used in their derivation. However, experimental determination of the coefficient values for C and Cv would compensate, making each equation produce the same discharge for the same measuring head. Either equation could be used. The examples given above show that traditional discharge equations are often a mixture of rational analysis and experimental coefficient evaluation.
2-14
However, recent development of computer modeling of long-throated flumes (Clemmens et al. [1991]) precludes the need for experimental determination of coefficients. These long-throated flumes are covered in chapter 8.
2-15
(h1 h2 )2 g A ( 1 )2 1 A2
(2-46)
Taking the square root of both sides and multiplying both sides by A1 results in the theoretical discharge equation:
Qt = V 1 A 1 = A 1
2 g (h1 h2 ) A ( 1 )2 1 A2
(2-47)
To obtain actual discharge, a coefficient, Cd, added to compensate for velocity distribution and for minor losses not accounted for in the energy equation yields:
Q a = Cd A 1
2 g (h1 h2 ) A ( 1 )2 1 A2
(2-48a)
Some investigators solve for discharge using throat area and velocity, resulting in:
Q a = Cd A 2
2 g (h1 h2 ) A 1 ( 2 )2 A1
(2-48b)
However, equations 2-48a and 2-48b are identical and can be converted to:
Q a = Cd A 1 A 2
2 g (h1 h2 )
A1 A2
2 2
(2-49)
Equations 2-48b and 2-49 also apply to nozzles and orifices in pipes. On figure 2-5, the hydraulic grade line, hgl, represents the pressure that acts on the walls of the venturi meter. An appreciable drop will be noticed at the narrow throat, and a gradual pressure rise is seen as the flow leaves the throat and smoothly spreads and slows in the expanding portion of the meter. Figure 2-6 shows the conditions that occur in a pipe orifice meter. As the flow approaches the orifice plate, the water near the pipe walls is slowed and stopped in the corners formed by the plate and the pipe walls. As a result, the pressure just ahead of the orifice at point B is a little greater than in the pipeline farther upstream at A. As the flow accelerates and passes through the orifice, the pressure drops and is lowest just downstream from the plate where the jet is smallest, and the velocity is highest at point C.
2-16
Farther down-stream, the flow begins to spread out and slow down, and a rise in pressure occurs at points D and E.
Figure 2-6 -- Pipe orifice meter. In both venturi meters and orifice meters, the pressure difference between the inlet tap and the throat or minimum pressure tap is related to discharge tables or curves using the suitable coefficients with the proper equation. An example discharge curve is shown for an 8-inch (in) venturi meter on figure 2-7. Thus, the meters may serve as reliable flow measuring devices.
(2-50)
Properly designed venturi meters and nozzles have no contraction, which makes Cc unity because of the smooth transitions that allow the water to flow parallel to the meter boundary surfaces. Ultimately, the actual discharge must be measured experimentally by calibration tests, and the theoretical discharge must be corrected. 2-17
A common misconception is that coefficients are constant. They may indeed be constant for a range of discharge, which is the case for many standard measuring devices. Complying with structural and operational limits for standard devices will prevent measurement error caused by using coefficients outside of the proper ranges. Some water measuring devices cover wider ranges using variable coefficients of discharge by means of plots and tables of values with respect to head and geometry parameters. Coefficients also vary with measuring station head or pressure tap location. Therefore, users should make sure that the coefficients used match pressure or head measurement locations. Water measurement equations generally require use of some to all of these coefficients to produce accurate results. Often, composite numerical coefficients are given that are product combinations of area or a dimension factored from the area, acceleration of gravity, integration constants, and the correction coefficients. However, geometry dimensions and physical constants, such as acceleration of gravity, are better kept separate from the nondimensional coefficients that account for the difference between theoretical and actual conditions. Otherwise, converting equations from English to metric units is more difficult. Equation 2-49 also applies to orifices and nozzles. The coefficient of discharge for venturi meters ranges from 0.9 to about unity in the turbulent flow range and varies with the diameter ratio of throat to pipe. The coefficient of discharge for orifices in pipes varies from 0.60 to 0.80 and varies with the diameter ratio. For flow nozzles in pipelines, the coefficient varies from 0.96 to 1.2 for turbulent flow and varies with the diameter ratio. ASME (1983) and ISO (1991) have a detailed treatment of pipeline meter theory, coefficients, and instruction in their use.
(2-51)
8 gRh S f
(2-53)
The coefficients C, n, and f are friction factors. The Darcy-Weisbach friction factor, f, is nondimensional and is a function of Reynolds number, 4RhV/L, and relative roughness, k/4Rh, in which L is kinematic viscosity, and k is a linear measure of boundary roughness size. The Reynolds number accounts for variation of viscosity. This function is given in the form of plots in any fluid mechanics textbook; for example, Streeter (1951), Rouse (1950), and Chow (1959). These plots are generally in terms of pipe diameter, D, which should be replaced with 4Rh for open channel flow. Values of k have been determined empirically and are constant for a given flow boundary material as long as the roughness can be considered a homogenous texture rather than large roughness elements relative to the depth. Solving equations 2-51, 2-52, and 2-53 for V/(RhS)1/2 results in a combined flow equation and relationship between the three friction factors, C, n, and f, written as:
1.49 Rh n
1/ 6
8g =C= f
V Rh S
(2-54)
Solving for velocity using equation 2-54 and multiplying by area produces a discharge equation and can be used in the slope area method of determining discharge as discussed in chapter 13. All three of these friction factors have been determined empirically, computed from measurement of equation variables. The Chezy factor, C, varies with hydraulic radius, slope, and physical boundary roughness. The Chezy factor varies from 22 to 220. Manning's friction factor, n, varies from 0.02 for fine earth lined channels to 0.035 for gravel. If the channel beds are strewn with rocks or are 1/3 full of vegetation, the n value can be as much as 0.06. The n values for concrete vary from 0.011 to 0.016 as finish gets rougher. Values of k can be found in hydraulic and fluid mechanics textbooks such as Streeter (1951), Rouse (1950), and Chow (1959). The value of k for concrete varies from 0.01 to 0.0001 ft depending on condition and quality of finishing. 2-19
Because Chezy and Manning equations and their friction factors have been determined for ordinary channel flows, they do not accurately apply to shallow flow, nor can these two equations be corrected for temperature viscosity effects. Values of k are constant for given material surfaces for k/4Rh equal or less than 1/10 and when 4RhV/ is greater than 200,000. Flow depths downstream are more likely the result of intentional structural restriction or water delivery head requirements downstream. Therefore, in designing and setting the elevation of flumes and weirs, the flow conditions just downstream need to be carefully assessed or specified in terms of required downstream operations and limits of measuring devices. More advanced hydraulic analyses are needed where normal flow is not established. For gradually varied flow, the friction equations can be used as trial and error computations applied to average end section hydraulic variables for relatively short reach lengths. The design and setting of crest elevations in an existing system permit the establishment of operation needs and downstream depths by actual field measurement.
If the control width is greater than 50 percent of the approach channel width, then 10 average approach flow widths of straight, unobstructed approach are required. If the control width is less than 50 percent of the approach width, then 20 control widths of straight, unobstructed approach are required. If upstream flow is below critical depth, a jump should be forced to occur. In this case, 30 measuring heads of straight, unobstructed approach after the jump should be provided. If baffles are used to correct and smooth out approach flow, then 10 measuring heads (10h1) should be placed between the baffles and the measuring station.
Approach flow conditions should be continually checked for deviation from these conditions as described in chapter 8 of this manual.
2-20
18. Bibliography
American Society of Mechanical Engineers, "Fluid Meters, Their Theory and Application," H.S. Bean, ed., Research Committee on Fluid Meters, sixth edition revised, New York, 1983. Bos, M.G. (ed.), Discharge Measurement Structures, 3rd edition, International Institute for Land Reclamation and Improvement, Publication 20, Wageningen, The Netherlands, 1989. Chow, V.T., Open-Channel Hydraulics, McGraw-Hill Book Company, Inc., 1959. Clemmens, A.J., M.G. Bos, and J.A. Replogle, "FLUME: Design and Calibration of LongThroated Measuring Flumes," version 3.0, International Institute for Land Reclamation and Improvement, Publication 54 (with software), The Netherlands, 1993. International Organization for Standardization, "Measurement of Flow by Means of Pressure Differential Devices," ISO 5167-1, Geneva, Switzerland, 1991. King, H.W., and E.F. Brater, Handbook of Hydraulics, fifth edition, McGraw-Hill Book Company, Inc., New York, 1963. Rouse, H., Elementary Mechanics of Fluids, John Wiley and Sons, Inc., New York, 1950. Schuster, J.S., "Water Measurement Procedures-Irrigation Operators Workshop," REC-OCE-7038, U.S. Bureau of Reclamation Publication, 1970. Streeter, V.L., Fluid Mechanics, McGraw-Hill Book Company, Inc., 1951.
2-21
Spurious errors are commonly caused by accident, resulting in false data. Misreading and intermittent mechanical malfunction can cause discharge readings well outside of expected random statistical distribution about the mean. A hurried operator might incorrectly estimate discharge. Spurious errors can be minimized by good supervision, maintenance, inspection, and training. Experienced, well-trained operators are more likely to recognize readings that are significantly out of the expected range of deviation. Unexpected spiral flow and blockages of flow in the approach or in the device itself can cause spurious errors. Repeating measurements does not provide any information on spurious error unless repetitions occur before and after the introduction of the error. On a statistical basis, spurious errors confound evaluation of accuracy performance. Systematic errors are errors that persist and cannot be considered entirely random. Systematic errors are caused by deviations from standard device dimensions. Systematic errors cannot be detected by repeated measurements. They usually cause persistent error on one side of the true value. For example, error in determining the crest elevation for setting staff or recorder chart gage zeros relative to actual elevation of a weir crest causes systematic error. The error for this case can be corrected when discovered by adjusting to accurate dimensional measurements. Worn, broken, and defective flowmeter parts, such as a permanently deformed, over-stretched spring, can cause systematic errors. This kind of systematic error is corrected by maintenance or replacement of parts or the entire meter. Fabrication error comes from dimensional deviation of fabrication or construction allowed because of limited ability to exactly reproduce important standard dimensions that govern pressure or heads in measuring devices. Allowable tolerances produce small systematic errors which should be specified.
Calibration equations can have systematic errors, depending on the quality of their derivation and selection of form. Equation errors are introduced by selection of equation forms that usually only approximate calibration data. These errors can be reduced by finding better equations or by using more than one equation to cover specific ranges of measurement. In some cases, tables and plotted curves are the only way to present calibration data.
Random errors are caused by such things as the estimating required between the smallest division on a head measurement device and water surface waves at a head measuring device. Loose linkages between parts of flowmeters provide room for random movement of parts relative to each other, causing subsequent random output errors. Repeating readings decreases average random error by a factor of the square root of the number of readings. Total error of a measurement is the result of systematic and random errors caused by component parts and factors related to the entire system. Sometimes, error limits of all component factors are well known. In this case, total limits of simpler systems can be determined by computation (Bos et al., 1991).
In more complicated cases, different investigators may not agree on how to combine the limits. In this case, only a thorough calibration of the entire system as a unit will resolve the difference. In any case, it is better to do error analysis with data where entire system parts are operating simultaneously and compare discharge measurement against an adequate discharge comparison standard.
3-2
Calibration is the process used to check or adjust the output of a measuring device in convenient units of gradations. During calibration, manufacturers also determine robustness of equation forms and coefficients and collect sufficient data to statistically define accuracy performance limits. In the case of long-throated flumes and weirs, calibration can be done by computers using hydraulic theory. Users often do less rigorous calibration of devices in the field to check and help correct for problems of incorrect use and installation of devices or structural settlement. A calibration is no better than the comparison standards used during calibration. Comparison standards for water measurement are systems or devices capable of measuring discharge to within limits at least equal to the desired limits for the device being calibrated. Outside of the functioning capability of the primary and secondary elements, the quality of the comparison standard governs the quality of calibration. Discrepancy is simply the difference of two measurements of the same quantity. Even if measured in two different ways, discrepancy does not indicate error with any confidence unless the accuracy capability of one of the measurement techniques is fully known and can be considered a working standard or better. Statistical deviation is the difference or departure of a set of measured values from the arithmetic mean. Standard Deviation Estimate is the measure of dispersion of a set of data in its distribution about the mean of the set. Arithmetically, it is the square root of the mean of the square of deviations, but sometimes it is called the root mean square deviation. In equation form, the estimate of standard deviation is:
S=
( X avg X Ind ) 2 ( N 1)
(3-1)
where:
S = the estimate of standard deviation XAvg = the mean of a set of values XInd = each individual value from the set N = the number of values in a set = summation
The variable X can be replaced with data related to water measurement such as discharge coefficients, measuring heads, and forms of differences of discharge. The sample number, N, is used to calculate the mean of all the individual deviations, and (N - 1) is used to calculate the estimate of standard deviation. This is done because when you know the mean of the set of N values and any subset of (N - 1) values, the one excluded value can be calculated. Using (N-1) in the calculation is important for a small number of readings.
3-3
For the sample size that is large enough, and if the mean of the individual deviations is close to zero and the maximum deviation is less than +3S, the sample distribution can be considered normally distributed. With normal distribution, it is expected that any additional measured value would be within +3S with a 99.7 percent chance, +2S with a 95.4 percent chance, and +S with a 68.3 percent chance. Measurement device specifications often state accuracy capability as plus or minus some percentage of discharge, meaning without actually stating, +2S, two times the standard deviation of discharge comparisons from a calibration. However, the user should expect an infrequent deviation of +3S. Error in water measurement is commonly expressed in percent of comparison standard discharge as follows:
E % Q Cs =
100(Q Ind QC s )
QC s
(3-2)
where:
QInd = indicated discharge from device output QCs = comparison standard discharge concurrently measured in a much more precise way
E % Q Cs = error in percent comparison standard discharge
Comparison standard discharge is sometimes called actual discharge, but it is an ideal value that can only be approached by using a much more precise and accurate method than the device being checked. Water providers might encounter other terms used by instrument and electronic manufacturers. Some of these terms will be described. However, no universal agreement exists for the definition of these terms. Therefore, water providers and users should not hesitate to ask manufacturers' salespeople exactly what they mean or how they define terms used in their performance and accuracy claims. Cooper (1978) is one of the many good references on electronic instrumentation. Error in percent full scale, commonly used in electronics and instrumentation specifications, is defined as:
E%QFS =
3-4
where:
QInd = indicated discharge QCs = comparison standard discharge concurrently measured QFS = full scale or maximum discharge E%QFS = error in percent full-scale discharge
To simply state that a meter is "3 percent accurate" is incomplete. Inspection of equations 3-2 and 3-3 shows that a percentage error statement requires an accompanying definition of terms used in both the numerator and denominator of the equations. For example, a flowmeter having a full scale of 10 cubic feet per second (ft3/s) and a full scale accuracy of 1 percent would be accurate to +0.1 ft3/s for all discharges in the flowmeter measurement range. Some manufacturers state accuracy as 1 percent of measured value. In this case, the same example flowmeter would be accurate to within +0.1 ft3/s at full scale; and correspondingly, a reading of 5 ft3/s would be accurate to within +0.05 ft3/s for the same flowmeter at that measurement.
3. Capability Terms
The term linearity usually means the maximum deviation in tracking a linearly varying quantity, such as measuring head, and is generally expressed as percent of full scale. Discrimination is the number of decimals to which the measuring system can be read. Repeatability is the ability to reproduce the same reading for the same quantities. Sensitivity is the ratio of the change of measuring head to the corresponding change of discharge. Range is fully defined by the lowest and highest value that the device can measure without damage and comply with a specified accuracy. The upper and lower range bounds may be the result of mechanical limitations, such as friction at the lower end of the range and possible overdriving damage at the higher end of the range. Range can be designated in other ways: (1) as a simple difference between maximum discharge (Qmax) and minimum discharge (Qmin), (2) as the ratio (Qmax/Qmin), called rangeability, and (3) as a ratio expressed as 1:(Qmin/Qmax). Neither the difference nor the ratios fully define range without knowledge of either the minimum or maximum discharge. Additional terms are related more to dynamic variability and might be important when continuous records are needed or if the measurements are being sensed for automatic control of canals and irrigation.
Hysteresis is the maximum difference between measurement readings of a quantity established by the same mechanical set point when set from a value above and reset from a value below. Hysteresis can continually get worse as wear of parts increases friction or as linkage freedom increases. Response has several definitions in the instrumentation and measurement fields. For water measurement, one definition for response is the smallest change that can be sensed and displayed as a significant measurement. Lag is the time difference of an output reading when tracking a continuously changing quantity.
3-5
Rise time is often expressed in the form of the time constant, defined as the time for an output of the secondary element to achieve 63 percent of a step change of the input quantity of the primary element.
4. Comparison Standards
Water providers may want or be required to have well developed measurement programs that are highly managed and standardized. If so, irrigation managers may wish to consult International Organization for Standardization (1983), American Society for Testing Materials standards (1988), American Society of Mechanical Engineers Test Codes (1992), and the National Handbook of Recommended Methods for Water Data Acquisition (1980). Research laboratories, organizations, and manufacturers that certify measurement devices may need to trace accuracy of measurement through the entire hierarchy of increasingly rigid standards. The lowest standards in the entire hierarchy of physical comparison standards are called working standards, which are shop or field standards used to control quality of production and measurement. These standards might be gage blocks or rules used to assure proper dimensions of flumes during manufacture or devices carried by water providers and users to check the condition of water measurement devices and the quality of their output. Other possible working standards are weights, volume containers, and stop watches. More complicated devices are used, such as surveyor's levels, to check weir staff gage zeros. Dead weight testers and electronic standards are needed to check and maintain more sophisticated and complicated measuring devices, such as acoustic flowmeters and devices that use pressure cells to measure head. For further measurement assurance and periodic checking, water users and organizations may keep secondary standards. Secondary standards are used to maintain integrity and performance of working standards. These secondary standards can be sent to government laboratories, one of which is the National Bureau of Standards in Washington, DC, to be periodically certified after calibration or comparison with very accurate replicas of primary standards. Primary standards are defined by international agreement and maintained at the International Bureau of Weights and Measurements, Paris, France. Depending upon accuracy needs, each organization should trace their measurement performance up to and through the appropriate level of standards. For example, turbine acceptance testing combined with severe contractual performance penalties might require tracing to the primary standards level.
3-6
where:
Q = the discharge in ft3/s C = 3.33, a constant for the weir L = the length of the weir in feet (ft) h1 = the observed head on the weir (ft)
If the length of the weir is 1.50 ft and the observed head is 0.41 ft, the significant equation output is 1.24 ft3/s. As a rule, in any computation involving multiplication or division in which one or more of the numbers is the result of observation, the answer should contain the same number of significant figures as is contained in the observed quantity having the fewest significant figures. In applying this rule, it should be understood that the last significant figure in the answer is not necessarily correct, but represents merely the most probable value.
3-7
where:
Q = discharge g = acceleration caused by gravity
h = upstream head minus the head on the downstream side of the orifice
A = the area of the orifice Cd = coefficient of discharge
Also, the coefficient of discharge, Cd, must be determined experimentally for any combination of orifice shape, measuring head locations, and the location of orifice relative to the flow boundaries. The coefficient has been found to be constant if the orifice perimeter is located away from the approach channel boundary at least a distance equal to twice the minimum orifice opening dimensions. Values of the discharge coefficient calculated by putting the measured calibration data into equation 3-5 may be constant within experimental error if the orifice geometry complies with all the requirements for standard orifices throughout the calibration range. An example set of discharge data is shown in table 3-1. The theoretical hydraulic equation 3-5 was used to compute values of the coefficient of discharge, Cd. The mean of the values (0.61) is the most probable equation coefficient based on 15 readings. The deviation or spread of individual coefficient values from the mean value would be the measure of the uncertainty of the measuring system as used during the calibration. The deviation of coefficient values is an indication of how well the calibration was done. Therefore, accuracy statements should also include statements concerning the head reading technique capability and the accuracy of the standard device used to measure discharge. If several orifices of the same size were calibrated together, then the accuracy statements can be made concerning limits of fabrication and installation of the orifices. The histogram of the same data as shown on figure 3-1 was developed by splitting the range of discharge values into five 0.005-ft3/s intervals. Then the data were tallied as they occurred in each interval. The plotted values of occurrence approach a symmetrical bell shape curve centered around the mean of 0.61, indicating that the data are random or normally distributed and that enough data were obtained to determine a meaningful average value for the discharge coefficient.
3-8
Table 3-1. An example of discharge data Head difference (ft) 0.253 0.245 0.232 0.209 0.197 0.189 0.163 0.161 0.154 0.127 0.109 0.100 0.073 0.060 0.050
Discharge (ft3/s) 3.702 3.613 3.545 3.361 3.267 3.172 3.005 2.924 2.842 2.565 2.450 2.323 1.986 1.813 1.640 Standard deviation =
Discharge coefficient 0.611 0.606 0.608 0.611 0.616 0.606 0.618 0.605 0.602 0.598 0.616 0.610 0.611 0.615 0.609 Cd = 9.142 Cd Avg = 0.610 S = 0.006
3-9
The measure of the spread of repeated measurements such as the discharge coefficient is the estimated standard deviation, which when using the form of equation 3-1 is written as:
S=
(C d C d Avg ) 2 ( N 1)
(3-6)
where denotes summation, and N is the number of Cd values. The value of S is the estimate of standard deviation, , which is approached more closely as the number of samples, N, becomes larger. Formal, small sample statistical methods can be used to evaluate confidence bounds around S based on sample size. After N has become large enough and normal distribution is verified, all previous and subsequent data are expected to fall within the bounds of +S, +2S, and +3S for about 68.3, 95.4, and 99.7 percent confidence levels, respectively.
3-10
To overcome the defect of using correlation coefficients that are based on log units, the flume measuring capability should be investigated in terms of percent discharge deviations, Q, or expressed as: Q% =
where: 100(Q E q QC s ) (3-9)
QC s
Q% = percent deviation of discharge QCs = measured comparison standard discharge QEq = discharge computed using measured heads and the regression equation
Then, calculate the estimate of standard deviation, S, and substitute Q% for Cd in equation 3-6F from the previous example. For the Parshall flume example, S was about 3.0 percent. The maximum deviation for the example flume was about -10 percent, and the average deviation was about 0.08 percent discharge, which is a small bias from the expected zero. Because of this small bias combined with a maximum absolute deviation of about 3S, the error was considered normally distributed, and the sample size, N, was considered adequate. Examples will be used to describe the next four sections.
3-11
Table 3-2. Determining sample standard deviation Head (h1) (ft) 1.012 1.017 1.014 1.010 1.015 1.013 1.012 1.014 1.013 1.011 Deviation (h1 - h1AVg) (ft) -0.0011 0.0039 0.0009 -0.0031 0.0019 -0.0001 -0.0011 0.0009 -0.0001 -0.0021 (Dev)2 (h1 - h1AVG)2 (square feet [ft2]) 0.00000121 0.00001521 0.00000081 0.00000961 0.00000361 0.00000001 0.00000121 0.00000081 0.00000001 0.00000441
(h1-h1AVg) = +0.0000
This calculation shows that estimating the staff gage +0.01 ft contributes up to +1.6 percent error in discharge at flows of about 9 ft3/s. 3-12
Both calculations are required because both could have been different depending on the discharge equation form and the value of discharge relative to measuring range limits.
Q = 9.99h13/2 (3-10)
Using this equation and making calculations similar to the previous example, they produce table 3-3. It is assumed that the water provider does not want to introduce more than 2 percent error caused by precision of head measurement. This amount of error is demarcated by the stepped line through the body of table 3-3. If the water providers needed to measure flow below 7 ft3/s, they would have to use stilling wells and vernier point gages. This line shows that heads could be measured with a staff gage at locations where all deliveries exceed about 7 ft3/s. They could select a higher cut-off percentage based on expected frequency of measurements at different discharges. The results of this type of analysis should be compared to the potential accuracy of the primary part of the measuring system.
Table 3-3. Discharge deviation Discharge (ft3/s) Equation Head (ft) Percent deviation of discharge at calibration head at a plus h1 of: h1 +0.002 ft Deviation (%) 18 9 5 3 2 1 1.481 0.933 0.630 0.448 0.342 0.216 0.25 0.37 0.53 0.72 0.92 1.40 h1 +0.01 ft Deviation (%) 1.0 1.6 2.7 3.6 4.4 7.0
3-13
Figure 3-2 -- Percent full-scale deviation of flow rate versus actual (comparison standard) flow rate. fit line slopes down to the right and passes through the zero error company claim of +2.0-percent full-scale accuracy is true. The best axis to the left of midrange. This meter could be made to have a better full-scale accuracy by shifting the meter output vertically and/or tilting its output by electronics or computer programming. The same data were converted and plotted in terms of percent comparison standard error of discharge using equation 3-11 on figure 3-3. To compare error in percent of actual discharge, E%Qact, with error in percent full-scale discharge, E%QFS, calculated contours of equal percent full scale were also plotted on figure 3-3.
E%Qact =
3-14
Q Ind QC s
(3-12)
A typical calibration check of a propeller meter mounted at the end of a pipe is plotted on figure 3-4. For this flowmeter, percent registration drops steeply below a discharge of 1 ft3/s. This result clearly indicates some of the problems of measuring near the lower range limits of this flowmeter. A slight increase of bearing friction will shift the dropping part of the curve to the right because the discharge at which the propeller will not turn will increase. Thus, in effect, the range is shortened on its low discharge end. The percent registration on the flat part of the curve near maximum registration will also decrease with age and wear of the flowmeter. In fact, the manufacturer may set meters, when they are new, to register high in anticipation of future wear. For example, they may set meters to read 3 to 5 percent high, expecting wear to lower the curve to about 100 percent registration at about mid-life of the flowmeter.
3-15
6. Bibliography
American Society for Testing and Materials, Annual Book of ASTM Standards, Water Environmental Technology, Section 11, Volume 11.01 Water (1), 1988. American Society of Mechanical Engineers, "Performance Test Codes-Hydraulic Turbines and Turbine Mode of Pump/Turbines," revision, Performance Test Code Committee No. 18, New York: The American Society of Mechanical Engineers, PTC 18-92, 1992. Bos, M.G. (ed.), Discharge Measurement Structures, third edition revised, Publication 20, International Institute for Land Reclamation and Improvement, Waneningen, The Netherlands, 1989. Cooper, W.D., Electronic Instrumentation and Measurement Techniques, Prentice-Hall, New York, 1978. International Organization for Standardization, Measurement of Liquid Flow in Open Channels, Handbook No. 15, Geneva, Switzerland, 1983. U.S. Geological Survey, Office of Water Data Coordination, National Handbook of Recommended Methods of Water-Data Acquisition, prepared cooperatively by agencies of the United States Government, Government Printing Office, Washington DC, 1980.
3-16
Weirs Flumes Submerged orifices Current meters Acoustic flowmeters Other open-channel devices Other closed conduit devices
The first four methods given above are discussed in considerable detail in this manual because they are the most common methods used. A variety of other devices for open channels and closed conduits is available-particularly for smaller rates of flow. These devices are discussed only briefly in chapters 11 and 12. This brief discussion does not mean that they are not useful devices. Such devices are appropriate for many applications.
3. Selection Considerations
The main factors which influence the selection of a measuring device include:
Accuracy requirements Cost Legal constraints Range of flow rates Head loss Adaptability to site conditions 4-1
Adaptability to variable operating conditions Type of measurements and records needed Operating requirements Ability to pass sediment and debris Longevity of device for given environment Maintenance requirements Construction and installation requirements Device standardization and calibration Field verification, troubleshooting, and repair User acceptance of new methods Vandalism potential Impact on environment
(a) Accuracy
The target or desired accuracy of the measurement system is an important consideration in measurement method selection. Most water measurement devices can produce accuracies of +5 percent. Some devices are capable of +1 percent under laboratory settings. However, in the field, maintaining such accuracies usually requires considerable expense or effort (e.g., special construction, recalibration, maintenance, etc.). Selecting a device that is not appropriate for the site conditions can result in a nonstandard installation of reduced accuracy, sometimes greater than +10 percent. Accuracies are usually reported for the primary measurement method or device. However, many methods rely on a secondary measurement, which typically adds error to the overall measurement. For example, the primary calibration for a weir is the relationship between head and discharge; this relationship typically contains a small error. However, the head must be measured, which potentially introduces additional error. Chapters 3 and 8 contain discussion and examples concerning the influence of secondary devices on accuracy.
(b) Cost
The cost of the measurement method includes the cost of the device itself, the installation, secondary devices, and operation and maintenance. Measurement methods vary widely in their cost and in their serviceable life span. Measurement methods are often selected based on the initial cost of the primary device with insufficient regard for the additional costs associated with providing the desired records of flows over an extended period of time.
4-2
Devices like weirs or flumes should be avoided if downstream water levels can, under some conditions, submerge the device. In addition, the information provided by the measuring device needs to be useful for the operators performing their duties. Devices that are difficult and time consuming to operate are less apt to be used and are more likely to be used incorrectly. In some cases, water measurement and water level or flow control need to be accomplished at the same site. A few devices are available for accomplishing both (e.g., constant-head orifice, vertically movable weirs, and Neyrpic flow module) (Bos, 1989). However, separate measurement and control devices are typically linked for this purpose. Special care is needed to assure that devices are compatible and, when used as a system, achieve both functions.
4-4
4-5
4-6
4. Selection Guidelines
Selection of a water measurement method can be a difficult, time-consuming process if one were to formally evaluate all the factors discussed above for each measuring device. Of course, this difficulty is one reason that standardization of measurement devices within a district is so popular. However useful devices are sometimes overlooked when similar devices are automatically selected. The purpose of this chapter is to provide some preliminary guidance on selection so that the number of choices can be narrowed down before a more thorough analysis of the tradeoffs between alternatives is performed.
4-7
The (+) symbol indicates positive features that might make the device attractive from the standpoint of the associated selection criteria. A (-) symbol indicates negative aspects that might limit the usefulness of this method based on that criteria. A (0) indicates no strong positive or negative aspects in general. A (v) means that the suitability varies widely for this class of devices. The letters (na) mean that the device is not applicable for the stated conditions. A single negative value for a device does not mean that the device is not useful and appropriate, but other devices would be preferred for those selection criteria. Table 4-1 - Application-based selection of water measurement devices 1. Open channel conveyance system 1. Natural channels 1. Rivers 1. Periodic current metering of a control section to establish 2. stage-discharge relation 3. Broad-crested weirs 4. Long-throated flumes 5. Short-crested weirs 6. Acoustic velocity meters (AVM - transit time) 7. Acoustic Doppler velocity profiles 8. Float-velocity/area method 9. Slope-area method 2. Intermediate-sized and small streams 1. Current metering/control section 2. Broad-crested weirs 3. Long-throated flumes 4. Short-crested weirs 5. Short-throated flumes 6. Acoustic velocity meters (AVM - transit time) 7. Float-velocity/area method 2. Regulated channels 1. Spillways 1. Gated 1. Sluice gates 2. Radial gates 2. Ungated 1. Broad-crested weirs (including special crest shapes, Ogee crest, etc.) 2. Short-crested weirs 2. Large canals 1. Control structures 1. Check gates 2. Sluice gates 3. Radial gates 4. Overshot gates
4-8
Table 4-1 - Application-based selection of water measurement devices (Cont.) 2. Other 1. Long-throated flumes 2. Broad-crested weirs 3. Short-throated flumes 4. Acoustic velocity meters 3. Small canals (including open channel conduit flow) 1. Long-throated flumes 1. Broad-crested weirs 2. Short-throated flumes 1. Sharp-crested weirs 3. Rated flow control structures (check gates, radial gates, sluice gates, overshot gates) 4. Acoustic velocity meters 5. Other 1. Float-velocity area methods 4. Farm turnouts 1. Pipe turnouts (short inverted siphons, submerged culverts, etc.) 1. Metergates 2. Current meters 3. Weirs 4. Long-throated flumes 5. Short-throated flumes 2. Other 1. Constant head orifice 2. Rated sluice gates 3. Movable weirs 2. Closed conduit conveyance systems 1. Large pipes 1. Venturi meters 2. Rated control gates (orifice) 3. Acoustic velocity meters (transit time) 2. Small and intermediate-sized pipelines 1. Venturi meters 2. Orifices (in-line, end-cap, shunt meters, etc.) 3. Propeller and turbine meters 4. Magnetic meters 5. Acoustic meters (transit-time and doppler) 6. Pitotmeters 7. Elbow meters 8. Trajectory methods (e.g., California pipe method) 9. Other commercially available meters
4-9
Table 4-2. Water measurement device selection guidelines. Symbols +. 0,Care used as relative indicators comparing application of water measurement devices to the listed criteria ("v" denotes device suitability varies widely, "na" denotes not applicable to criteria) Device Flows Flows Flow Head Accuracy Cost >150 <10 span loss ft3/s ft3/s Site conditions
Lined Unlined Short canal canal full pipe Sharp-crested weirs Broad-crested weirs Long-throated flumes Short-throated flumes Submerged orifices (in channels) Current metering Acoustic velocity meters n an open channel Radial and sluice gates Propeller meters at pipe exit Differential head meters for pipe1 Mechanical velocity meters for pipe2 Magnetic meters for pipe Acoustic Doppler ultrasonic meters for pipe Acoustic flowmeter pipe (single path) Acoustic flowmeter pipe (multipath)
1 2
Closed conduit na na na na na na na na + + + + + + +
0 0 0 0 0 + 0 0 0 +
0 + 0 0 0 + + + 0 0 -
+ + + 0 0 0 +
+ + + 0 + 0 0 + 0 0 0 0
0 + + 0 0 0 0 0 0 +
0 0 + + + V + + + + +
+ + 0 0 0 + 0 na na na na na na
0 0 0 0 0 0 + 0 na na na na na na
na na na na na na na + + 0 0 -
Venturi, orifice, pitot tube, shunt meters, etc. Propeller meters, turbine meters, paddle wheel meters, etc.
Table 4-2 - Water measurement device selection guidelines. Symbols +. 0,Care used as relative indicators comparing application of water measurement devices to the listed criteria ("v" denotes device suitability varies widely, "na" denotes not applicable to criteria) (continued) Device Measurements Sediment/Debris Longevity Maintenance Construction Field Standardization verify
ElecSediment Debris Moving Rate Volume tricity pass. pass. parts needed Sharpcrested weirs Broadcrested weirs Longthroated flumes Shortthroated flumes Submerged orifices (in channels) Current metering Acoustic velocity meters in an open channel Radial and sluice gates Propeller meters at pipe exit Differential head meters for pipe1 Mechanical velocity meters for pipe2 Magnetic meters pipe + + + 0 0 +
+ +
+ 0
+ 0
+ 0
0 +
+ 0
0 +
+ 0
0 0
+ -
0 0
+ -
+ +
Acoustic Doppler ultrasonic meters for pipe Acoustic flowmeter pipe (single path) Acoustic flowmeter pipe (multipath)
1 2
Venturi, orifice, pitot tube, shunt meters, etc. Propeller meters, turbine meters, paddle wheel meters, etc. The process of narrowing down options might start with table 4-1 to examine the main methods to consider. Table 4-2 can then be used to get an idea of the general positive and negative features of various methods. In narrowing down the options, different applications will place different weight on the selection criteria, so no universally correct selection exists. Finally, a preliminary design for several candidate methods selected should be performed so that details on cost, hydraulics, operations, etc., can be more thoroughly examined C followed by final selection, design, and construction.
(b) Example
We want to measure the flow entering a small farm turnout ditch that serves an agricultural field. The ditch is trapezoidal, concrete-lined and has a rectangular metal sluice gate that is opened by hand to divert flow into the ditch from a canal lateral. No power is available at the site. The ditch carries a flow of about 10 cubic feet per second (ft3/s). Field survey measurements taken during an irrigation indicate about a 0.75-ft drop in the water surface from the gate to the downstream channel. The irrigation flow transports fine sediment and numerous tumble-weeds. Water is diverted to the field on a 2-week rotation for a period of about 24 hours. The measurement device will be used to establish a known flow rate through the headgate for crop yield management and water use accounting. Typically, the water surface in the lateral remains fairly constant during an irrigation; therefore, a single measurement per irrigation will meet current needs. However, in the future, more frequent measurements may be desired. The irrigator would like to install a device that costs less than $500. Table 4-1 identifies a number of devices that are typically used for farm turnouts. Our site requires we select a device or method that can be used in an open channel. Therefore, common measurement devices given for this application are: current meters, weirs, flumes, and rated sluice gates (headgates). Next, the advantages or disadvantages for each of these devices should be considered with respect to the measurement goals and the site conditions. Table 4-2 is used to assist in comparing the attributes of devices. 4-12
Typically, only a few selection constraints are high priorities. The selection priorities for the example are likely: meeting available head, cost, accuracy, and debris passage goals. Head loss is the highest priority because it is a physical constraint of the site that must be met to provide good measurement. Current meters provide the least head loss followed by long-throated flumes (including broad-crested weirs), short-throated flumes, and sharp-crested weirs. Sluice gates rate low in terms of head loss; however, for this application, the gate is part of the site and will not provide additional head loss. Based on our highest priority, current metering, a long-throated flume or rating the headgate are good choices. Next, consider the cost of devices including: initial cost, data collection time, and maintenance. Rating the headgate and a long-throated flume are considered to be a lower cost than current metering largely because of the time involved in data collection. Accuracy of measurement and debris passage favor a long-throated flume. This example selection process identifies a long-throated flume as potentially the best device followed by rating of the headgate. These two methods of measurement are recommended for additional detailed design and evaluation prior to the final selection.
5. Bibliography
Bos, M.G., (ed.), Discharge Measurement Structures, third revised edition, International Institute for Land Reclamation and Improvement, Publication No. 20, Wageningen, The Netherlands, 1989.
4-13
Then, curves and/or tables must be prepared. Installation and proper inspection and maintenance of standard devices are not difficult and are less costly in the long run. Standard discharge tables may then be used with full confidence.
3. Approach Flow
Poor flow conditions in the area just upstream from the measuring device can cause large discharge indication errors. In general, the approaching flow should be tranquil. Tranquil flow is defined as fully developed flow in long, straight channels with mild slopes, free of close curves, projections, and waves. Venturi meters require 10 diameters of straight pipe approach. By analogy, open channel flow would require 40 hydraulic radii of straight, unobstructed approach. A good example of practical approach criteria taken from Bos (1989) follows:
If the control width is greater than 50 percent of the approach channel width, then 10 average approach flow widths of straight, unobstructed approach are required. If the control width is less than 50 percent of the approach width, then 20 control widths of straight, unobstructed approach are required. If upstream flow is below critical depth, a jump should be forced to occur. In this case, 30 measuring heads of straight, unobstructed approach after the jump should be provided. If baffles are used to correct and smooth out approach flow, then 10 measuring heads should be placed between the baffles and the measuring station.
Deviation from a normal transverse or vertical flow distribution, or the presence of water surface boils, eddies, or local fast currents, is reason to suspect the accuracy of the measuring device. Errors of 20 percent are common, and errors as large as 50 percent or more may occur if the approach flow conditions are very poor. Sand or gravel bars, weed growths, or slumped riprap obstructions along the banks or in the flow area can cause nonsymmetrical approach flow. Inadequate distance downstream from a drop, check, or slide gate will concentrate flow locally and cause error. A bend or angle in the channel just upstream from the measuring device or a rapid expansion in the flow section can cause secondary flow or large eddies, which tend to concentrate the flow in part of a cross section. Figure 5-1 shows an example of a poor flow distribution in the approach to a weir. The highvelocity, turbulent stream is approaching the weir at a considerable angle. The high-velocity approach flow and the waves on the surface hinder head measurement. With this poor approach flow, the weir will not produce the same head-discharge relationship as its standard equation and calibration table.
5-2
Figure 5-1 -- Example of poor approach flow conditions upstream from weir. Standard weir proportions for rectangular, Cipoletti, and 90-degree Vnotch weirs are shown on figure 5-2. The approach velocity toward weirs should be less than 0.5 foot per second (ft/s). This velocity value is equivalent to a head error of 0.005 ft. Velocity of approach can be estimated by dividing the maximum discharge by the area at a point 4 to 6 measuring heads upstream from the blade. Excess approach velocity is commonly caused by violating the criteria specified in chapter 7.
4. Turbulence
Turbulence results from relatively small parcels of water spinning in a random pattern within the bulk flow while moving downstream. Turbulence may be recognized as water surface boils or three dimensional eddies which appear and disappear haphazardly. Because of this local motion within the general motion of the bulk flow, any particle of water may, at any given instant, move forward, sideways, vertically, or even backward. In effect, the water is passing a given point with accelerating and decelerating motion superimposed upon the main flow rather than with a uniform, ideal velocity. Thus, more or less water may pass a given point over a short length for short time periods, depending on the observation point chosen (figure 5-1). 5-3
Excessive turbulence will adversely affect the accuracy of any measuring device but is particularly objectionable when using current meters or propeller meters of any kind. Turbulence can be objectionable even without air entrainment or the "white water" often associated with turbulence. Turbulence is commonly caused by stilling basins or other energy dissipaters, by a sudden drop in water surface, or by obstructions in the flow area such as turnouts-- operating or not--that have projections or indentations from the supply canal. Shallow flow passing over a rough or steep bottom can also cause turbulence. Weeds or riprap slumped into the flow area or along the banks, or sediment deposits upstream from the measuring device, also can cause excessive turbulence. Excessive turbulence can cause measuring errors of 10 percent or more. Therefore, the flow approaching a measuring structure or device should be modified to resemble tranquil canal flow.
Figure 5-3 -- Underpass wave suppressor. The channel may be either rectangular or trapezoidal in cross section. Constructing the suppressor four times as long as the flow is deep can reduce waves as much as 93 percent. The suppressor produces a slight backwater effect for the most effective vertical placement. The suppressor may be supported on piers, can be constructed of wood or concrete, and need not be watertight. 5-4
The design of several other suppressor types, along with example cases, is covered in Peterka (1983). Figure 5-4 shows turbulence and waves in a Parshall flume produced by an outlet works stilling basin, which makes accurate discharge determination impossible. The log raft in the foreground was used in an attempt to quiet the flow; however, the raft was later lifted out of the water because of ineffectiveness.
Figure 5-4 -- Turbulence and waves in a Parshall flume produced by an outlet works stilling basin. The log raft failed to quite the flow. Figure 5-5 shows the water surface after removal of the log raft and installation of an underpasstype wave suppressor. This modification significantly reduced the turbulence and waves, making accurate discharge determination a routine matter.
Figure 5-5 -- Underpass-type wave suppressor reduces turbulence and waves in Parshall flumes.
5-5
Figure 5-6 -- Weir approach flow. The water surface is considerably lower at the weir blade than it is at 5 ft upstream. The elevation difference between the two circled points on the surface of the approach flow is called the velocity head and represents the potential required to produce the increase in velocity between the points. A drop in water surface of 0.1 ft is common just upstream from a weir and (from the equation above) represents an increase in velocity of 0.8 ft/s. If the head on the weir is measured too close to the weir, the head measurement can be up to 0.1 ft too small. For a weir 6 ft long, with a head of 0.45 ft, a discharge of 7 ft3/s is indicated. If you measured the head too close to the weir, such that the head was reduced by 0.1 ft, a discharge of 5 ft3/s would be indicated. This difference amounts to an error of about 35 percent based on the reported discharge; and, more importantly, the water provider would be giving away 2 ft3/s. Standard weir tables are based on the measured head of the weir (velocity head is negligible) and do not compensate for excessive velocity head. Any increase in velocity above standard conditions, therefore, will result in measuring less than the true head on the weir. Therefore, more water will be delivered than is measured. Causes of excessive velocity head include inadequate pool depth upstream from the weir, deposits in the upstream pool (figure 5-7), and poor lateral velocity distribution upstream from the weir.
Figure 5-7 -- Sediment deposits in weir pool. Figure 5-7 shows sediment deposits, which have reduced the depth of the weir significantly and increased the velocity of the approach to well above the desirable level. Other problems exist as well; the head gage should not be located this close to the weir blade, the weeds should be removed, and the "edge" of the weir should be sharp. Discharges over this weir will be larger than indicated in "standard" tables. 5-6
5-7
If the head upstream from the weir is pulled down a significant amount, then the weir is not sufficiently ventilated. An easy test for sufficient ventilation is to part the nappe downstream from the blade for a moment with a hand or a shovel to allow a full supply of air to enter beneath the nappe. After removing the hand or shovel, the nappe should not gradually become depressed (over a period of several or more minutes) toward the weir blade. If the upper nappe profile remains the same as it was while fully ventilated, the weir has sufficient ventilation. If the nappe clings to the downstream side of the weir and does not spring clear, the weir may discharge up to 25 percent more water than the head reading indicates. This problem is generally a low flow problem with heads near and less than 0.2 ft and occurs more frequently with V-notch weirs. Good practice would involve checking the nappe before and after readings. Gates calibrated only for free discharge at partial openings should not be submerged, nor should eddies interfere with the jet of water issuing from the gate. Gaging stations should be kept free of deposited sediment bars or other side-projecting obstructions to prevent backflow or eddies from interfering with the uniform flow conditions that should exist in the cross section being measured.
Inaccurate weir blade lengths or Parshall flume throat widths, insufficient or nonexistent weir nappe ventilation, or incorrectly located and zeroed head or staff gages cause measuring errors. A transverse slope on a sharp-crested weir blade can cause errors, particularly if the gage zero is referenced to either end. The error can be minimized by determining the discharge based on the head at each end and using the average discharge. Errors in setting the gage zero are the same as misreading the head by the same amount. At low heads, a relatively small zero setting error can cause errors of 50 percent or more in the discharge. A head determination error of only 0.01 ft can cause a discharge error of from 5 percent on a 90degree V-notch weir to over 8 percent on a 48inch (in) Cipoletti weir (both for a head of 0.20 ft). The same head error on 6 and 12in Parshall flumes can result in 12- and 6-percent errors, respectively, for low heads. Out of plumb or skewed weir blades will show flow measurement inaccuracies of measurable magnitude if the weir is out of alignment by more than a few degrees. Rusted or pitted weir blades or those having projecting bolts or offsets on the upstream side can cause errors of 2 percent or more depending on severity of the roughness. Any roughness will cause the weir to discharge more water than indicated. Rounding of the sharp edge of a weir or reversing the face of the blade also tends to increase the discharge. On older wood crests, a well rounded edge can cause a 15- to 25-percent or more increase in discharge (figure 5-8). The well-rounded edge on the once sharp-crested weir on figure 5-8 will increase the discharge to well above "standard." The weeds are also undesirable, as is the weir gage which projects into the flow area.
Figure 5-8 -- Poorly maintained weir edge. Certain types of meters require pressure readings to determine discharges. Piezometers, or pressure taps, as they are sometimes called, must be regarded with suspicion when considering flow measurement accuracy.
5-9
Piezometers or pressure head taps must be installed with care and with a knowledge of how they perform; otherwise, indicated pres-sure values can be in error. For example, as shown on figure 5-9, the four piezometers indicate different pressure readings (water levels) because of the manner in which flow passes the piezometer opening. Piezometer openings are shown larger than they should be constructed in practice. Always use the smallest diameter opening consistent with the possibility of clogging by foreign material. Unless the piezometer is vertical as in Y, the water elevation will be drawn down as in X or increased as in Z. Basically, pressure taps should be perpendicular to the flow boundary, and the flow must be parallel to the boundary. Rough edges or burrs on or near the edges of the piezometer holes deflect the water into or away from the piezometer, causing erroneous indications. The case as in W shows the tube pushed into the flow, causing the flow to curve under the tip which pulls the water level down. Errors caused by faulty piezometer tap installation increase with velocity.
Figure 5-9 -- Examples of piezometer installation. Sometimes, to obtain a better average pressure reading, four taps around the pipe are manifolded. If unbalanced pressure exists because of velocity distribution, error can be introduced by flow circulation in the manifolding tubing. Two forms of manifolding are shown on figure 5-10. The commonly seen case (a)-circular form-causes circulation errors. Case (b) is the triple tee system, designed to minimize circulation errors. Large tube diameter relative to piezometer hole diameter through the meter wall will reduce circulation error considerably for both cases.
5-10
Figure 5-10 -- Examples of piezometer manifold tubing (top: poor arrangement; bottom: good compensating arrangement). Large-diameter tubing relative to piezometer diameter will reduce circulation errors considerably for both cases. Frequently, pressure taps are connected to manometers and U-tubes (figure 5-11), and air trapped in the tubing can cause large errors. Air travels in bubbles that tend to rise and form large air blockages. Thus, piezometers should not be connected at the top of a pipe. Even with taps on the side, air will come out of solution as water warms. Air in the vertical parts of the tubing causes large errors. Although air in horizontal parts of the tubing does not cause error, a bubble will likely move to a vertical part of the tubing when flow increases or decreases. For bleeding air, flowmeters should be placed at locations where the pipelines are under positive pressure; that is, where the hydraulic grade line is well above the pipe and manometry system as shown on figure 5-11.
5-11
Figure 5-11 -- Manometry system below the hydraulic grade line is desirable. If the meter and/or manometer are above the grade line as shown on figure 5-12, then pressure is negative. Negative pressure causes air to come out of solution and accumulate. Also, air can leak through pipe fittings and flange gaskets into the pipe and manometer system. Air can leak through openings that water cannot leak through.
Figure 5-12 -- Manometry system above the hydraulic grade line is undesirable. Care in designing the system should be taken to make sure that the hydraulic grade line is above the tubing system at maximum water delivery. Otherwise, bleeding will have to be done frequently with separate water source purging, or water delivery will have to be shut off to provide positive pressure during bleeding. When the hydraulic grade line is below the system, the negative pressure causes air to accumulate faster. This condition should be avoided if at all possible. The effect of a few deficiencies often found in measuring devices has been given to illustrate the degree of error to be expected in making ordinary measurements under ordinary conditions. Other effects have not or cannot be stated in terms of percent error without an exact definition of the degree of fault or deterioration. The examples given should be sufficient to emphasize the importance of careful and exact installation practices as well as regular and prompt repair or rehabilitation of the devices after they have been installed. 5-12
Figure 5-13 -- Cipoletti weir operating with good flow conditions in the approach pool. Figure 5-13 shows a Cipoletti weir performing properly for the discharge shown. Flow is well distributed across the wide pool and shows no evidence of excessive turbulence. Accurate or "standard" discharges can be expected under these conditions. At larger discharges, the nonsymmetrical approach may produce undesirable conditions. The principles described above also apply to head measurements on broad-crested weirs and flumes, meter gates, or any other device dependent on a head measurement for discharge determination. Improper gage location, or an error in head measurement in a flume, can result in large discharge errors because of water surface curvature. Incorrect flume throat width dimensions and weir lengths can also produce errors. The relative ease of making accurate length measurements usually keeps these errors small. However, operators should check lengths in the field rather than rely on values stated or shown on drawings. 5-13
Readings obtained from stilling wells, whether visual or recorded, should be questioned unless the operator is certain that the well intake pipe is not partially or fully clogged with sediment or air pockets. Data from an overactive stilling well can also be misleading, particularly if longperiod surges occur in the head pool. In fact, all head determinations should be checked to ensure that the reading is not part of a long period surge. A sufficient number of readings, about 10, should be taken at regular time intervals of about 15 seconds, and averaged to obtain the average head. More readings may be required if consecutive readings indicate that the pool is continuing to rise or fall. If this process takes too much time, the cause of the instability should be determined and eliminated. Readings from gages or staffs which may have slipped or heaved should be avoided. Periodic rough checks can sometimes be made with a carpenter's level or square from a reference point on another structure. A still-ponded water level at the weir crest height is a valuable check on the staff gage zero. Each operator should understand the desired measurement and then critically examine each operation to ensure that the correct measurement is being taken. The operator should try to find fault with every step in the head measurement process and attempt to improve techniques wherever possible.
12. Bibliography
Bos, M.G., Discharge Measurement Structures, third revised edition, International Institute for Land Reclamation and Improvement, Publication No. 20, Wageningen, The Netherlands, 1989. Peterka, A.J., Hydraulic Design of Stilling Basins and Energy Dissipaters, Engineering Monograph No. 25, United States Department of the Interior, Bureau of Reclamation, Denver, Colorado, 1983. Schuster, J.S. (ed.), "Water Measurement Procedures-Irrigation Operator's Workshop," RECOCE-70-38, United States Department of the Interior, Bureau of Reclamation, Denver, Colorado, 1970. 5-15
2. Datum of Gage
A convenient and meaningful elevation datum should be selected for the station. The operating datum for the station should be set below the water-stage elevation for zero flow. The operating datum can be referenced to mean sea level. The datum should be permanent for the expected life of the station and should be referenced to at least two or three other benchmarks that are independent of the gaging structure.
3. Measurement Method
Two basic philosophies can be used to determine stage or gage height-direct and indirect. Direct methods involve a measurement of the height from the liquid level to a datum line; an indirect method infers the stage level from some other characteristic, such as the head read by a pressure transducer.
4. Nonrecording Gages
Two general types of nonrecording gages are in use: (1) staff gages, on which readings of stage are made directly; and (2) chain, wire weight, float-type, and hook gages, with which measurements are made from fixed points. Staff gages may be either vertical or inclined. The inclined type should be carefully graduated and accurately installed to ensure correct stage readings. Most permanent gages are enameled steel plates bolted in sections to the staff. This kind of staff gage is shown on figure 8-4 in chapter 8. Care should be taken to install the gages solidly to prevent errors caused by changes in elevation of the supporting structure. A chain gage is a substitute for the staff gage and consists of a horizontal scale and a chain that passes over a pulley to attach to a hanging weight (figure 6-1). Chain gages may be mounted on a bridge that spans (or any other structure that overhangs far enough) over the stream. Water stage is indicated by raising or lower the weight until it just touches the water surface and reading the position of the chain index mark on the horizontal scale. 6-1
Chain gages are affected by settling of the structure that supports them, changes in load on the structure, temperature changes, and changes in length as the chain links wear. Wind may also introduce errors by not allowing the weight to remain in a vertical position.
Figure 6-1 -- Chain gage. The wire weight gage is a modification of the chain gage and uses a wire or small cable wound on a reel. The reel is graduated, or a counter is used to give readings to tenths and hundredths of a foot. A check bar of known elevation is often provided so that lowering the weight onto the bar will produce a reading on the counter or reel, which can be compared with the reference elevation. A wire weight gage is shown on figure 6-2.
6-2
5. Recording Gages
Water-stage recorders consist of a group of instruments that produce a record of water surface elevation with respect to time. The output can be analog (providing a graphical result) or digital (punched paper tape or stored or transmitted values). Important advantages of recorders over nonrecording staff gages are: (1) In streams having daily fluctuations, continuous records provide the most accurate means of determining the daily average gage height. (2) Maximum and minimum stage are recorded, and the time they occurred can be noted. (3) Records can be obtained at stations where observers are not always available.
Figure 6-3 -- Horizontal drum water-stage recorder. The time element records parallel to the axis of the drum. (courtesy Leupoild and Stevens Instruments, Inc.).
6-3
These types of recorders usually operate using 8-day, spring-driven clocks. Electrical drives could also be used if a reliable source were readily available. The stylus, usually either a capillary pen or a pencil of proper hardness, must be capable of operation for the full 8 days without attention. To accommodate various water-stage differentials, ratios of water-stage change to recorder-chart change are available from 1:1 to 10:1 and should be specified at the time the recorder is ordered. The standard width of recorder paper is 10 inches (in), and all recorders come equipped with metal covers. The fourth type of graphic recorder is shown on figures 6-4 and 6-5. The time element, consisting of a compensated, balanced, weight-driven clock, drives two parallel rolls, one of which holds the supply paper. The paper unrolls from the supply roll at a uniform rate and with constant tension and is taken up on the receiving roll. Speed of travel may be adjusted from 0.3 to 9.6 in per day on any standard instrument, and other chart speeds are available on special order. The normal chart length is 75 feet (ft).
Figure 6-4 -- Continuous recording water-stage recorder with cover raised. The time element rotates the rolls, and the height element records parallel to the axis of the rolls. (courtesy Leupoild and Stevens Instruments, Inc.).
Figure 6-5 -- Typical installation of a continuous water-stage recorder in a wooden shelter. The float activates a pen stylus which moves parallel to the axis of the rolls so that 1 in of travel represents a change in water stage of 1 ft. The stylus is designed so that it can be accurately set for gage height. The ratio of water surface change to stylus travel can also be adjusted to accommodate small to large ranges of depth. The range of the recorder is limited only by the length of the float cable because the stylus reverses direction at the point of maximum deflection. Capacity of the ink reservoir is sufficient for the recorder to operate for 60 days or longer.
6-5
Figure 6-6 -- Digital recorder. Water stage is transmitted to the punched-paper tape recorder, usually through shaft rotation on a float and pulley arrangement. Shaft rotation is converted by the recorder into coded punch-tape records (figure 6-7). The code consists of four groups of four punches each. In each group, the first punch represents "1"; the second, "2"; the third, "4"; and the fourth, "8." Thus, a combination of 1, 2, or 3 appropriate punches in a given group represents digits from 1 to 9. A blank (no punch) represents zero. Together, the four groups of punches represent all numbers from 0 to 9999.
6-6
Figure 6-7 -- Digital recorder punched tape. (courtesy U.S. Geological Survey). Coding is done by either one or two identical disks that have raised ridges on the faces. Figure 66 shows a digital recorder with only one disk, which produces 2-digit numbers ranging from 0 to 99. Two disks would be used if 3- or 4-digit numbers are required. The right-hand disk is connected directly to the input shaft, and the left-hand disk is driven from the first disk by a 100to-1 worm-gear reducer. One-hundred revolutions of the input shaft and the first disk cause one revolution of the second disk. A paper tape is moved upward through the punch assembly in the center of the instrument. The punch block contains a row of 18 pins or punches-16 for information and 2 for feeding the tape. At the selected intervals of time, the punch assembly is pivoted on a shaft at the bottom, so the punch, paper, and pins are moved toward the disks. Those pins that strike raised ridges on the disks are forced through the paper, punching neat round holes. The pins that do not strike ridges do not punch holes. This record reflects the position of the disks, which is proportional to the water stage, all as a function of time. 6-7
The mechanically punched tape is still widely used at this time (1996) and is considered very practical for field use where temperature, moisture, and power conditions are widely variable. Electronic translators can convert punched tape records into suitable input for digital computers. The most recent advances have been in the area of data loggers. This group of electronic instruments has evolved quickly over the last 10 years. Small, battery-operated, fully programmable units offer many features in addition to data recording (figure 6-8). Some type of transducer is required to sense the water stage with this type of recorder. Options range from a pressure transducer sensing water level in a stilling well to a pressure transducer on a bubbler system, to an angular transducer sensing shaft rotation on a float-driven system. In all cases, an analog (voltage or current) output is sensed, digitally recorded, and stored by the data logger. This type of system is perhaps best suited to the transmission of data via satellite or microwave, providing a central control location with current water stage information. Remote sites are very well suited to being powered by batteries which are charged through small solar cells. However, vandalism of the solar panels can be a problem because they must be exposed. Concealing solar panels in some way (such as in the top of a tree) can help.
because of waves and turbulent fluctuations on the scale face. If the wall of a flume is relatively thin, the flume channel is connected directly by an orifice through the wall shared by the flume and stilling well to improve head reading. Separate or more remote wells are connected by pipes through thicker walls and embankments. Thus, the average water surface outside the well is translocated into the well, and the waves and fluctuations are dampened. 6-8
Polyvinyl chloride, polyethylene, and galvanized-iron pipes, sealed on the lower end with an opening in the side, make excellent wells. Some older stilling wells were made from tongue-and-groove creosoted lumber and worked satisfactorily. Sewer pipe of suitable size with tightly sealed joints has also been used. On a flume, stilling wells are often formed of the same material as the flume. Because the primary purpose of the stilling well is to prevent oscillations of the float caused by surging water or wave action, the well must be firmly anchored to prevent movements that could introduce oscillations within the well. Surges and wind waves of the outside water surface can be dampened by restricting the area of an inlet port through a relatively thin wall to about 1/1,000 of the inside horizontal crosssectional area of the well. If the stilling well is served by a long connecting pipe, the diameter should be increased to produce the same effective dampening. Thin wall port diameters are about 1/30 the diameter of the wells, and connecting pipeline diameters are about 1/20 the diameter of the well. Thin wall port and connecting pipe diameters for different sized stilling wells for full dampening are tabulated below: Table 6-1. Stilling well dimensions for full dampening Stilling well size 12-in diameter 16-in diameter 20-in diameter 24-in diameter 30-in diameter 36-in diameter 3- by 3-ft square 3- by 4-ft rectangular 4- by 5-ft rectangular Thin through walls or short inlet pipes Diameter (in) 1/2 1/2 5/8 3/4 1 1-1/4 1-1/4 1-1/2 2 Connecting pipes 20 to 30 ft long diameter (in) 1/2 3/4 3/4 1 1-1/2 2 2 3 4
These table dimensions are used for connecting reservoirs and flumes where head remains relatively steady during reading and lag time is unimportant. Frequently, for actively changing discharge systems or very remote wells, connecting pipes must be large enough to allow recorder floats to respond quickly and to follow the water level changes. Usually, this pipe diameter is about 1/10 the diameter of the stilling well. Also, the connecting pipe can be oversized, and a gate valve that has the same head loss for flow in both directions can be provided for throttling. The gate valve allows throttling to the required amount of dampening. However, the piping system from the inside wall of the flume channel to the inside wall of the well must have the same form and friction losses for pulses of flow in both directions. The gate valve must be located so that a distance of at least 20 pipe diameters exists on both sides of the valve. The gate valve should be centered. 6-9
If required, the gate valve could be opened fully for cleaning or to closely follow continually changing water level, or the valve could be throttled to prevent wide oscillation of ink pens. The pipe connection to the stilling well wall and flow channel wall should be perpendicular and carefully cut flush with the inside walls of the well and flume flow channel. Otherwise, the translocated water surface elevation in the well can deviate considerably from the actual mean elevation in the flume because of velocity impact and unbalanced head losses. The size of the stilling well depends on the method used to measure the head. The diameter, if circular shaped, could range from a recommended minimum size of 4 in for hand-inserted dipsticks to 18 in to accommodate larger diameter floats. Wells may be much larger to provide access for cleaning or to make the reading of wall attached staff gages at sight angles at least as flat as 30 degrees. An overly steep sight angle will hinder accurate reading of water surface elevation on the staff gradations. It is recommended that well walls have a 2-in clearance from floats used with recorders. Weights should have adequate clearance from well walls. A stilling well may need to house the float and recorder system or other surface detecting equipment. The wells may need to be tall enough to provide convenient access to recorders for reading, reference setting, and maintenance. The wells may need to be tall enough to keep counterbalance weights from interfering with float movement. Before making a measurement, the wells should be flushed with fresh water to be sure they are free of sediment, foreign material, or blockages, which could cause erroneous head readings. Recording equipment should be checked and serviced regularly. Cross checks should be made between the staff gages, hook gages, plumb bobs, recorder values, and any other discharge indicators to expose system errors. Thus, even when using stilling wells, staff gages should still be used on the inside walls of flumes for cross checking. Further details on stilling wells can be found in table 8.1 of chapter 8 (Bos et al., 1991; Brakensiek, 1979). Figures 6-9 and 6-10 show designs of typical installations of a more permanent nature. Installation cost is an important consideration in the selection of a structure. Shelters often become attractive targets for firearms, so higher initial costs of permanent installations may be offset by savings in undamaged equipment and complete records. Figure 6-11 shows a current meter gaging station with cable, car, corrugated steel shelter house, and stilling well.
6-10
Figure 6-10 -- Plans for reinforced concrete recorder house and stilling well.
Figure 6-11 -- Current-meter gaging station with cable car, corrugated steel shelter house, and stilling well. If a continuous record of water stage is required at a particular location, the cost of a concrete gage house and stilling well is usually justified. Figure 6-12 shows plans for a typical concrete structure used by the U.S. Geological Survey (Wahl et al., 1995). Considerable care must be used in construction to minimize settling or cracking of the concrete.
Figure 6-12 -- Plans for smooth and corrugated steel pipe recorder housing and stilling wells (sheet 1 of 2).
Figure 6-12 -- Plans for smooth and corrugated steel pipe recorder housing and stilling wells (sheet 2of 2). The intake pipes on most stilling wells require occasional cleaning, especially on streams and canals carrying sediment. A flushing tank and pump cannot be justified on any but permanent installations (figure 6-9). The tank is filled with a hand pump, and a sudden release of the tank water will usually flush out the intake piping. For tightly clogged pipes or temporary or semipermanent stilling wells, a sewer rod or "snake" provides the most satisfactory means for cleaning. The use of plugged crosses instead of tees and elbows in the piping system allows for the easy insertion of the cleaning rods or "snakes."
Erroneous readings from a gaging station are many times directly related to the setting or shifting of the datum.
10. Bibliography
Bos, M.G., J.A. Replogle, and A.J. Clemmens, 1991, Flow Measuring Flumes for Open Channel Systems, John Wiley & Sons, 1984, and American Society of Agricultural Engineers, New York, 1991. Brakensiek, D.L., H.B. Osborn, and W.R. Rawls (coordinators/ editors), Field Manual for Research in Agricultural Hydrology, Agricultural Handbook 224, U.S. Department of Agriculture, U.S. Government Printing Office, Washington, DC, 1979. Buchanan, T.J., and W.P. Somers, "Stage Measurement at Gaging Stations," Chapter 10, Book 1, Surface Water Techniques Series, U.S. Geological Survey, Washington, DC, 1965. Wahl, K.L., W.O. Thomas, Jr., and R.M. Hirsch, "The Stream-Gaging Program of the U.S. Geological Survey," Circular 1123, U.S. Geological Survey, Washington, DC, 1995. 6-14
2. Definition of Weirs
A measuring weir is simply an overflow structure built perpendicular to an open channel axis to measure the rate of flow of water. Inspecting and checking the critical parts of weir structures for degradation and improper operation are easy. A properly built and operated weir of a given shape has a unique depth of water at the measuring station in the upstream pool for each discharge. Thus, weirs can be rated with respect to an upstream head relative to the crest elevation versus discharge, and equations or tables which apply to the particular shape and size weir can be generated. The crest overflow shape governs how the discharge varies with head measurement.
7-1
7-2
Figure 7-1 -- Different kinds of sharp-crested weirs. When the distances from the sides of the weir notch to the sides of the weir pool are greater than two measurement heads, the water will flow relatively slowly along the bulkhead face toward the overflow opening. As the water from the sides of the channel nears the notch, it accelerates and has to turn to pass through the opening. This turning cannot occur instantaneously, so a curved flow path or side contraction results in which the water springs free to form a jet narrower than the overflow opening width. Flow coming along the bottom of the weir pool and up a sufficiently high bulkhead and weir plate springs upward and forward in the curved, underside jet surface or crest contraction. The falling sheet of water springing from the weir plate is the nappe. After passing the head measuring station or about a distance of two head measurements upstream from the overflow opening, the water surface drops more and more as flow approaches the crest. This continuing drop of water surface or drawdown results from the acceleration of the water as it approaches the weir. The drop in water surface between the measuring station and the notch is equal to the change of velocity head, or V2/2g, between these stations as explained in section 7 in chapter 2. The term vertical contraction includes both crest contraction and drawdown at the weir plate. When approach conditions allow full contractions at the ends and at the bottom, the weir is a contracted weir. For full contraction, the ends of the weir should not be closer to the sides and bottom of the approach channel than a specified distance. 7-3
Full side contractions on a thin-plate Cipolletti weir are shown on figure 7-2. If the specified distances are not met, then the weir is partially contracted.
Figure 7-2 -- Cipolletti weir operating with full contractions at the end and on the crest. When sides of the flow channel act as the ends of a rectangular weir, no side contraction exists, and the nappe does not contract from the width of the channel. This type of weir is a suppressed weir and is shown on figures 7-1 and 7-3. To reproduce the full vertical rating, contraction of the suppressed weir that existed during its calibration requires full air ventilation under the nappe and the proper crest elevation.
Velocity of approach is equal to the discharge divided by the flow section area at the head measuring station. Velocity of approach is important because it can change weir calibrations by effectively reducing the crest length and/or measuring head. In addition, a variable discharge coefficient results as increasing velocity changes the curvature of flow springing from the weir plates. Free flow occurs when a thin-plate weir allows free access of air under the falling jet sheet or nappe. With free flow, head measurements at one upstream location determine discharge with knowledge of weir size and shape.
Downstream water rising above the weir crest elevation produces a submerged weir condition. When the downstream water surface is near or above the crest elevation of a sharp-crested weir, accuracy of measurement should not be expected. "Submerged flow correction methods" or "submerged calibrations" only produce estimates of discharge. 7-4
The use of a submerged weir as a water measurement device is not good practice and should only be done as a temporary, emergency procedure. Because of the large loss of accuracy, designing thin-plate weirs for submergence should be deliberately avoided. However, submergence may happen unexpectedly or may be temporarily necessary. In such cases, flow can be estimated using special techniques discussed in Skogerbe et al. (1967), but not on a longterm basis. A weir discharge measurement consists of measuring depth or head relative to the crest at the proper upstream location in the weir pool, and then using a table or equation for the specific kind and size of weir to determine discharge. Commonly, a staff gage, described in chapter 6, having a graduated scale with the zero placed at the same elevation as the weir crest, measures head. Putting staff gages in stilling wells dampens wave disturbances when reading head. Using vernier hook point gages in stilling wells produces much greater accuracy than staff gages. These staff gages must be zero referenced to the weir crest elevation. Section 7 in chapter 8 provides more information regarding measuring head and related errors.
Rectangular weirs V-notch weirs from 25 degrees to 100 degrees Cipolletti (trapezoidal) weirs
Equations for weirs determine discharge values used to produce tables for field use. However, users and designers must pay due respect to specific limits such as calibration range, velocity of approach, setting requirements, dimension tolerances, and operating techniques. A few weir tables are extended by measured data outside of equation limits.
7-5
(c) The edges of the weir opening should be located in one plane, and the corners should have proper specified angles. (d) The top thickness of the crest and side plates should be between 0.03 and 0.08 inch (in). (e) All weir plates should have the same thickness for the entire boundary of the overflow crest. If the plates are thicker than specified in condition (d), the plate edges shall be reduced to the required thickness by chamfering the downstream edge of the crest and sides to an angle of at least 45 degrees; 60 degrees is highly recommended for a V-notch to help prevent water from clinging to the downstream face of the weir. (f) The upstream edges of the weir opening plates must be straight and sharp. Edges of plates require machining or filing perpendicular to the upstream face to remove burrs or scratches and should not be smoothed off with abrasive cloth or paper. Avoid knife edges because they are a safety hazard and damage easily. (g) The bottom edge plates and fastener projection upstream should be located a distance of at least two measuring heads from the crest. If not, the plates must be inset flush with the upstream face of the supporting bulkhead, and the fasteners must be countersunk on the upstream pool side. Upstream faces of the plates must be free of grease and oil. (h) The overflow sheet or nappe should touch only the upstream faces of the crest and side plates. (i) Maximum downstream water surface level should be at least 0.2 foot (ft) below crest elevation. However, when measuring close to the crest, frequent observations are necessary to verify that the nappe is continually ventilated without waves periodically filling the under nappe cavity. (j) To prevent the nappe from clinging to the downstream face of the weir, the head measurement should be greater than 0.2 ft. Conditions (d), (e), and (f) also help to prevent clinging. If measurements must be made at heads approaching this value for substantial periods, operators must ensure the head measuring system has commensurate precision with respect to needed accuracy and must continually check for clinging. (k) The measurement of head on the weir is the difference in elevation between the crest and the water surface at a point located upstream from the weir a distance of at least four times the maximum head on the crest. (l) Keep the approach to the weir crest free of sediment deposits. All the approach flow conditions as discussed in section 17 of chapter 2 of this manual apply. Additional requirements and limitations specific to different types of weirs follow.
7-6
Q = discharge, cubic feet per second (ft3/s) e = a subscript denoting "effective" Ce = effective coefficient of discharge, ft1/2/s Le = L + k b h1e = h1 + kh
In these relationships:
kb = a correction factor to obtain effective weir length L = measured length of weir crest B = average width of approach channel, ft h1 = head measured above the weir crest, ft kh = a correction factor with a value of 0.003 ft
The factor kb changes with different ratios of crest length, L, to average width of approach channel, B. Values of kb for ratios of L/B from 0 to 1 are given on figure 7-4. The factor kh is a constant value equal to 0.003 ft.
Figure 7-4 -- Value of width-adjustment factor from Georgia Institute of Technology tests (courtesy of American Civil Society of Engineers).
7-7
The effective coefficient of discharge, Ce, includes effects of relative depth and relative width of the approach channel. Thus, Ce is a function of h1/p and L/B, and values of Ce may be obtained from the family of curves presented on figure 7-5. p is the vertical distance from the weir crest to the approach pool invert.
Figure 7-5 -- Effective coefficient of discharge, Ce, as a function of L/B and h1/p, from Georgia Institute of Technology tests (courtesy of American Civil Society of Engineers). The straight lines on figure 7-5 have the equation form:
Ce = C1 (h1/p) + C2 (7-2)
where:
Ce = effective coefficient of discharge C1 = equation coefficient h1 = head on the weir (ft) p = height of crest above approach invert (ft) C2 = equation constant
For convenience, the coefficients and constants for straight lines of each L/B on figure 7-5 are given in the following tabulation for interpolation:
7-8
Table 7-1. Coefficient and constants used in determining the effective coefficient of discharge for the Kindsvater-Carter method
L/B
0.2 0.4 0.5 0.6 0.7 0.8 0.9 1.0
C1
-0.0087 0.0317 0.0612 0.0995 0.1602 0.2376 0.3447 0.4000
C2
3.152 3.164 3.173 3.178 3.182 3.189 3.205 3.220
The straightforward, comprehensive, and accurate Kindsvater-Carter method of determining discharges for rectangular weirs is well suited for discharge rating use. It is particularly useful for installations where full crest contractions or full end contractions are difficult to achieve. Traditional rectangular weirs that do not meet crest height limits or that are using the older methods of correcting for velocity of approach should be recalibrated using the KindsvaterCarter method. Weirs that fall out of the limits of the Kindsvater-Carter rating curves need replacement or field calibration by thorough current metering. Limits on usage and dimensions are:
The calibration relationships were developed with rectangular approach flow and head measurement sections for these weirs. For applications with other flow section shapes, the average width of the flow section for each h1 is used as B to calculate discharges. The crest length, L, should be at least 6 in. The crest height, p, should be at least 4 in. Like all weirs used for head measurement, h1 should be at least 0.2 ft . Values of h1/p should be less than 2.4. All the requirements in section 5 apply. The downstream water surface elevation should be at least 2 in below the crest. All the approach flow conditions in chapter 2 apply .
Q = 4.28 Ce tan (
) h1e5/2(7-3)
7-9
where:
Q = discharge over weir in ft3/s Ce = effective discharge coefficient h1 = head on the weir in ft h1e = h1 + kh = angle of V-notch
The head correction factor, kh, is a function of (figure 7-6a). However, for fully contracted traditional 90-degree V-notch weirs, equation 7-6 and the rating table discussed later produce comparable accuracy.
Figure 7-6a -- Head correction factor, kh, for V-notches of any angle (courtesy of National Bureau of Standards, Kulin et al. [1975]).
Figure 7-6b -- Effective coefficient, Ce, for fully contracted V-notches of any angle (courtesy of National Bureau of Standards, Kulin et al. [1975]). For fully contracted V-notch weirs, the value of kh is related to as given on figure 7-6a, and values of Ce are read from figure 7-6b. Partially contracted 90-degree V-notches only can be rated using figure 7-7 to obtain Ce values. The calibration relationships were developed with rectangular approach flow and head measurement sections for these weirs. For applications with other flow section shapes, the average width of the flow section for each h1 is used as B to determine coefficients. 7-10
Figure 7-7 -- Effective coefficient, Ce, for partially contracted 90-degree V-notches (courtesy of National Bureau of Standards, Kulin et al. [1975]). Bos (1989) and International Organization for Standardization (1983) explain and define limits basic to the use of these figures. Precautions and restrictions concerning the use of V-notch weirs are as follows: (a) V-notch weirs should not be designed beyond the range of the parameters plotted on figures 7-6 and 7-7. Only the 90-degree V-notch weir can be made partially contracted through the use of figure 7-7. (b) The water surface downstream from the weir should always remain at least 0.2 ft below the notch. Lower discharge readings should be rejected if the contraction is not springing underneath for the entire nappe length. (c) The measuring head should be greater than 0.2 ft because precision of head measurement error is large relative to smaller head depths, and the nappe may cling to the weir plate. (d) For the fully contracted V-notch, the maximum measuring head should be less than 1.25 ft. (e) For the partially contracted V-notch, the maximum head should be less than 2 ft. (f) For fully contracted V-notches, the h1/B ratio should be equal to or less than 0.2. (g) For the partially contracted 90-degree notch, h1/B should be equal to or less than 0.4. (h) The average width of the approach channel, B, should always be greater than 3 ft for the fully contracted V-notch. (i) For the partially contracted 90-degree V-notch, the approach channel width should be greater than 2 ft. (j) The V-notch of the weir should always be located at least 1.5 ft above the invert of the weir pool for fully contracted weirs. (k) Only the 90-degree V-notch can be partially contracted, but the point of the notch must be located at least 4 in from the channel invert. (l) All the requirements in section 5 apply. 7-11
Q = 3.33h13/2(L-0.2h1) (7-4)
where:
Q = discharge in ft3/s neglecting velocity of approach L = the length of weir in ft h1 = head on the weir in ft
The Francis equation has a constant discharge coefficient which facilitates computations without the use of tables. However, the coefficient does not remain constant for a ratio of head-to-crest length greater than one-third, and the actual discharge exceeds that given by the equation. Francis' experiments were made on comparatively long weirs, most of them with a 10-ft crest and heads ranging from 0.4 ft to 1.6 ft. Thus, these equations apply particularly to such weirs. The Bureau of Reclamation (Reclamation) experiments on 6in, 1ft, and 2-ft weirs on the Boise Project in Idaho show that the equation also applies fairly well to shorter crest lengths, provided the head of water on the weir is not greater than about one-third the length of the weir.
The prefix A indicates that the tables(s) are located in the Appendix. 7-12
For most sizes of these weirs, the values of discharge in table A7-2 end when the measurement head reaches one-third of the crest length, the limit of the equation. Reclamation, Boise Project, calibrated weirs to extend the head range of contracted rectangular weirs. Their calibrations are included in the table for the 6-in, 1-ft, and 2-ft crest lengths and are indicated by shaded entries in the tables.
Figure 7-8 -- Section through suppressed weir with air vent in wall. Other conditions for accuracy of measurement for this type of weir are identical to those of the contracted rectangular weir, except those relating to side contraction and the crest height. The crest height should be equal to at least 3h1max. A suppressed weir in a flume drop is illustrated on figure 7-3. 7-13
(a) Equation for Standard Suppressed Rectangular Weirs With Full Bottom Contraction
The Francis equation for the standard suppressed rectangular weir (figure 7-1) is:
7-14
7-15
7-16
Figure 7-10 -- Compound weir with 90-degree notch and suppressed rectangular crest used by U.S. Forest Service. The compound weir, as described, has a disadvantage. When the discharge begins to exceed the capacity of the V-notch, thin sheets of water will begin to pass over the wide horizontal crests. This overflow causes a discontinuity in the discharge curve (Bergmann, 1963). Therefore, the size and elevation of the V-notch should be selected so that discharge measurements in the transition range will be those of minimum importance. Determining discharges over compound weirs has not been fully investigated either in the laboratory or in the field. However, an equation has been developed on the basis of limited laboratory tests on a 1-ft-deep, 90-degree V-notch cut into rectangular notches 2, 4, and 6 ft wide to produce horizontal extensions of L=0, L=2, and L=4 ft, respectively (Bergmann, 1963). The weirs were fully contracted, and heads up to 2.8 ft above the notch point were used. The equation is as follows:
where:
Q = discharge in ft3/s h1 = head above the point of the V-notch in ft L = combined length of the horizontal portions of the weir in ft h2 = head above the horizontal crest in ft
When h1 is 1 ft or less, the flow is confined to only the V-notch portion of the weir, and the standard V-notch weir equation 7-6 is used. Further testing is needed to confirm this equation before it is used for weirs beyond the sizes for which it was developed.
Figure 7-11 -- Weir box turnout with Cipolletti weir. Simmons and Case (1954) and Palde (1972) studied this concept further to improve approach flow velocity distribution, still the water surface at the gages, and increase discharge measuring capacity, accuracy, and head differential between the supply canal head elevation and weir pool. To achieve narrower box widths, suppressed rectangular weirs were installed for full size laboratory tests. These tests developed system arrangements, box and weir dimensions, and stilling baffle arrangements (figures 7-12c and 7-13) and calibrations for discharges up to 12 ft3/s and for canal and weir pool head differences up to 6 ft. Suppressed rectangular weirs 3 and 4 ft long were used rather than Cipolletti weirs to simplify the structure and increase capacity. 7-18
To meet three different conditions likely to be encountered in the field, the three designs for 5.0ft3/s maximum measuring capacity shown on figure 7-12 were prepared.
Figure 7-12a -- Standard designs for 5.0-ft3/s weir box turnout (sheet 1 of 3).
Figure 7-12b -- Standard designs for 5.0-ft3/s weir box turnout (sheet 2 of 3).
Figure 7-12c -- Standard designs for 5.0-ft3/s weir box turnout (sheet 3 of 3).
Figure 7-13 -- Baffle arrangement and rating table for 12-ft3/s weir box turnout. The type 1 turnout weir box (figure 7-12a) is placed immediately adjacent to the supply canal with the turnout inlet recessed into the side of the canal. The type 2 turnout (figure 7-12a) is placed farther from the canal. Maximum discharge for turnout types 1 and 2 is 5.0 ft3/s with a maximum head drop between the canal water surface and the weir pool surface of 3.0 ft. The type 3 (figure 7-12b) turnout is designed for 5.0 ft3/s with a head drop of up to 6.0 ft. Instead of having the square bottom gate at the weir pool headwall, the gate is moved to the canal pipeline inlet. Discharges through types 1 and 2 weir box turnouts are determined by measuring the weir pool head, h1, on the weir gage provided just above the baffles and wave suppressor, measuring the head drop, Y, using the weir gages both upstream and downstream from the gate, and using the table of discharge on figure 7-12b. Both weir gages should be set at the same elevation. Discharges through type 3 turnouts are determined by the single measurement of weir pool head, h1, and the table of discharge on figure 7-12b, depending on maximum design discharge measurement capacity. The baffle arrangement and rating table for the 12-ft3/s maximum capacity weir box developed by Palde (1972), shown on figure 7-13, incorporates a suppressed weir. This weir box is installed in gate, pipe, and box configuration similar to the smaller discharge capacity weir box in the type 3 turnout using the dimensions and baffle arrangement shown on figure 7-12b, which also shows the calibration chart. All four designs are arranged to permit easy construction as in-place structures or as precast units. All use reinforced concrete for the main box and headwalls and use separate, easily replaced, wooden or metal baffle assemblies in the weir pool. 7-20
A space is left open at the upstream face of the baffle so any accumulations of weeds and debris can be removed. Design and construction details for the 5- and 12-ft3/s weir boxes are given in Aisenbrey et al. (1978).
Broad-crested weirs can be computer calibrated. A broad-crested weir could be considered if rusting, impact, abrasion, etc., might cause maintenance problems with a flat-plate weir. Specially shaped weirs can be designed to fit more complicated channel cross sections better, and the shape control section can be selected to provide special discharge ranging and variation needs with respect to head. Some forms of broad-crested weirs pass floating debris and sediment better than sharp thin-plate weirs, especially those with round nose or ramp approach transitions. Submergence does not affect broad-crested weirs up to about 80 percent with a vertical downstream drop and up to about 90 percent with sloped downstream transitions.
No clear-cut classification distinction or hydraulic difference exists between broad-crested weirs and long-throated flumes. Computer calibrations of broad-crested weirs use the principles and theories that are used for long-throated flumes. Thus, broad-crested weirs such as flat crests across trapezoidal and circular flow channels are covered in chapter 8.
7-21
Figure 7-14 -- Adjustable Cipolletti weir in a division box. A form of a movable crest broad-crested weir is discussed in Bos (1984) and Bos et al. (1991). This publication also shows how movable weirs can be arranged to provide shutoff and sediment sluicing provided enough channel drop is available.
Figure 7-15 -- Sectional view of an overshot gate. Although water level control is useful, operators also need to know the flow rate at each gate to better operate systems. Wahlin and Replogle (1994) further developed the Kindsvater and Carter (1959) calibration approach for a sloping leaf gate as a weir by modifying equation 7-1 with a gate angle correction coefficient, Ca, as follows: 7-22
Ca = correction factor for angle of the gate Ce = effective discharge coefficient for a vertical weir from figure 7-5 or equation 7-2 Le = effective crest length he = effective measurement head
An empirical plot (figure 7-16) for Ca was determined from laboratory tests. For values of h1/p less than 1.0 and for gate angles between 16.2 degrees and 63.4 degrees, the relationship for Ca is:
Figure 7-16 -- Correction factor, Ca, versus gate leaf angle, , for use in equation 7-9. The angle, , is measured in the direction of the flow between the channel invert and the underside of the gate leaf in degrees. Ca = 1.0333 + 0.003848 - 0.000045 2 (7-10) These equations can determine the flow rate in the field of a properly ventilated free-flow leaf gate to within about 6.4 percent. These equations were tested against hydraulic laboratory modeling and field data. Eventually, with further testing, these authors expect to verify that their derived submergence functions will provide submerged flow calibrations to within about 10 percent. This accuracy estimation for submerged flow rate does not include errors associated with head measurement. An example computation of free overshot discharge follows. For a leaf gate that is 6.5 ft wide and 9.75 ft long, sloping at 40 degrees, mounted with the hinge point about 3 in above the invert, and a measurement head, h1, of 3.25 ft, calculate the free flow discharge.
7-23
The overfall edge of a leaf gate is in a region of no side contraction; therefore, the effective discharge coefficient can be calculated assuming no side contractions of the weir. Thus, figure 7-7 or equation 7-2 with a C1 of 0.40 and C2 of 3.22 are used to calculate a value for the effective discharge coefficient, Ce, as 3.42 at h1/p of 0.5. Because no effects caused by side contractions were assumed, a value of -0.003 ft is assigned to Kb (figure 7-4). Kindsvater and Carter (1959) also recommend that a constant value of 0.003 ft be assigned to Kh regardless of the flow rate or gate height. Thus, Le is 6.497 ft, and he is 3.253 ft. Because h1/p is less than 1.00, and the gate angle is between 16.2 and 63.4 degrees, equation 7-8 can be used to determine that Ca is 1.115. Then, equation 7-7 is used to calculate discharge as below:
Q = (1.115)(3.42)(6.497)(3.253)1.5 (7-0)
Q = 145.3 ft3/s
7-24
Figure 7-17 -- Discharge equation for short-crested triangular weir (SCS Agriculture Handbook No. 244).
These differential heads are small relative to the ability to measure head precisely. Therefore, submergence correction procedures should be only a temporary emergency procedure to provide estimates. The need for submergence correction should be eliminated directly by maintenance and cleaning of weeds, sediment, and other debris from the downstream channel, changing system operations, raising the crest, or installing another kind of measuring device since correction estimates are only within +15 percent. Flow cannot be estimated for submerged partially contracted Kindsvater-Carter and KindsvaterShen calibrated weirs discussed in sections 6 and 7.
A sill at the downstream end of the basin will help prevent bottom shear flow on the channel bed downstream from the basin. Bos (1989) has discussion of designing basins for water measurement structures and designing riprap with proper underbase material. Chapter 4 has further information on weirs but may indicate selection of a device other than a weir.
Standard equations and tables are valid only when sufficient ventilation is provided. The weir will deliver more water than indicated by the tables and equations when ventilation is inadequate. This inaccuracy occurs because the nappe sheet seals with the sidewalls, and the falling jet aspirates air from the cavity. The exiting flow carries the aerated water away, causing a negative pressure under the nappe. The negative pressure and some jet backflow raise the water behind the nappe sheet higher than the water exiting just downstream. The height of pullup behind the nappe depends upon the drop, discharge, and crest length. The height that the water is pulled up behind the nappe is an estimate of the discharge error. For example, if the measuring head on a 3-ft suppressed weir is 1 ft, and the water behind the nappe pulls up 0.3 ft because of air demand, the error of discharge measurement would be about +6.5 percent. If the water was only pulled up 0.1 ft, the error for the same weir and measuring head would be +2.5 percent. However, some of the rise of water behind the nappe is due to backflow from the falling jet. The design of pipe size to introduce sufficient air depends on the discharge, drop, and the loss of accuracy that is tolerable. Sizing air piping and air vents requires some knowledge of fluid mechanics and is difficult to do. Bos (1989) gives the equations to compute the undernappe pressure and a plot of discharge error versus under-nappe pressure for sizing air vents. The weir structure should be set in a straight reach of the channel, perpendicular to the line of flow. The weir crest must be level and the bulkhead plumb. Adequate cutoff walls well tamped in place should be used on the weir structure to prevent undermining of the structure. The average width of the approach channel should be set to approximately conform to the size of the box for a distance of 10 to 20 ft upstream for the smaller structures and from 50 to 70 ft or more for the largest structures. The weir box may accumulate sand and silt to such an extent that discharge measurements will be incorrect. For sluicing silt and sand deposits, an opening may be provided in the weir bulkhead at the floor line beneath the weir notch. This sluiceway should be provided with a suitable cover or gate to prevent leakage. If sediment is a severe problem, then sedimentexcluding vortex tubes that bypass bed load with a small continuous flow may be more desirable than inaccuracies resulting from silt and sand.
If leakage does occur, remedial action should be immediately followed with careful rechecking to see that the weir is level and that its elevation corresponds to the zero elevation of the measuring gage. In any case, the crest of the weir should be checked periodically to verify that it is level and to verify correspondence to gage zero. Care must be taken to avoid damaging the weir notch itself. Even small nicks and dents can reduce the accuracy of an otherwise good weir installation. Any nicks or dents that do occur should be carefully dressed with a fine-cut file or stone, stroking only in the plane of the upstream face of the weir plates or the plane of the beveled surface of the weir plates. Under no circumstances should any attempt be made to completely remove an imperfection, which will result in a change to the shape of the weir opening. Instead, only those portions of the metal that protrude above the normal surfaces should be removed.
19. Bibliography
Ackers, W.R., J.A. Perkins, and A.J.M. Harrison, Weirs and Flumes for Flow Measurement, John Wiley & Sons, New York, 1978. Aisenbrey, A.J., Jr., R.B. Hayes, H.J. Warren, D.L. Winsett, and R.B. Young, Design of Small Canal Structures, Bureau of Reclamation, Denver, Colorado, 1978. Bergmann, J.M., Compound Weir Study, Hydraulic Laboratory Report No. Hyd-505, Bureau of Reclamation, April 5, 1963. Bos, M.G. (ed.), Discharge Measurement Structures, International Institute for Land Reclamation and Improvement, Publica-tion 20, third revised edition, Wageningen, The Netherlands, 1989. Brakensiek, D.L., H.B. Osborn, and W.R. Rawls (coordinators/editors), Field Manual for Research in Agricultural Hydrology, Agricultural Handbook 224, U.S. Department of Agriculture, U.S. Government Printing Office, Washington, DC, 1979. Francis, J.B., Lowell Hydraulics Experiments, D. Van Nostrand, fourth edition, New York, New York, 1883. International Organization for Standardization, "Measurement of Liquid Flow in Open Channels," Handbook No. 15, Geneva, Switzerland, 1983. King, H.W., and E.F. Brater, Handbook of Hydraulics, fifth edition, McGraw-Hill Book Company, Inc., New York, 1963. Kindsvater, C.E., and R.W. Carter, "Discharge Characteristics of Rectangular Thin-Plate Weirs," Paper No. 3001, Transactions, American Society of Civil Engineers, vol. 124, 1959. Kulin, G., and P.R. Compton, "A Guide to Methods and Standards for the Measurement of Water Flow," Special Publication 421, National Bureau of Standards, 1975.
7-29
Palde, U.J., Hydraulic Laboratory Studies of a 4-Foot-Wide Weir Box Turnout Structure for Irrigation Use, Report REC-ERC-72-31, Bureau of Reclamation, Denver, Colorado, September 1972. Shen, J.A., "Preliminary Report on the Discharge Characteristics of Trapezoidal-Notch ThinPlate Weirs," U.S. Geological Survey, July 1959. Simmons, W.P., and W.D. Case, Hydraulic Model Studies of Small Weir Box Turnout Structures for General Irrigation Use, Hydraulic Laboratory Report No. Hyd-396, Bureau of Reclamation, Denver, Colorado, October 21, 1954. Skogerboe, G.V., L.M. Hyatt, and K.O. Eggleston, "Design and Calibration of Submerged Open Channel Flow Measurement Structures, Part 4-Weirs," Report WG31-5, Utah State University, May 1967. Wahlin, B.T., and J.A. Replogle, Flow Measurement Using an Overshot Gate, published for Reclamation by UMA, Inc., 1994.
7-30
2. Flume Classes
Many kinds of flumes are in use. The two basic classes or forms of flumes are discussed below.
Long-throated flumes can have nearly any desired cross-sectional shape and can be custom fitted into most canal-site geometries. The modified broad-crested weirs (Replogle, 1975; Bos et al., 1991), also called ramp flumes (Dodge, 1983), are styles of long-throated flumes.
(b) The long-throated flume (broad-crested weir) with approximatly 1,200 ft3/s. Figure 8-1 -- Large long-throated flume for left to right flow in Arizona canal (courtesy of U.S. Water Conservation Laboratory, Phoenix, Arizona).
8-2
Figure 8-2 -- Four-foot, short-form Parshall flume, discharging 62 ft3/s under free-flow conditions. Scour Protection is needed for this much drop.
8-3
(a) H-Flumes
H-flumes, developed by the Natural Resources Conservation Service (former known as the Soil Conservation Service) (Brakensiek, et al., 1979; Kulin et al., 1975), are made of simple trapezoidal flat surfaces. These surfaces are placed to form vertical converging sidewalls. The downstream edges of the trapezoidal sides slope upward toward the upstream approach, forming a notch that gets progressively wider with distance from the bottom. These flumes should not be submerged more than 30 percent. This group of flumes, including H-flumes, HS-flumes, and the HL-flumes (Brakensiek et al., 1979; Gwinn and Parsons, 1976) have been used mostly on small agricultural watersheds and have not found extensive use in irrigation flow measurements.
8-4
Although these early versions were laboratory calibrated, more recently, they were found to conform to the analysis procedures for long-throated flumes for heads less than about 50 percent of maximum. For higher depths, their throats become too short for precise long-throated flume analysis, and the laboratory ratings should be used. Except for those already in existence, and for which the user may need calibrations, these flumes are generally being replaced with versions having longer throats, making them long-throated flumes that can be calibrated by analysis.
4. Submergence
All flumes have a minimum needed head loss to assure that free flow exists and that only an upstream head measurement is needed to determine discharge rate. This required head loss is usually expressed as a submergence limit defined by the ratio of the downstream head to the upstream head, both referenced to the flume throat bottom. The term "modular limit" is defined as this limiting submergence ratio for a particular flow module, which causes no more than a 1percent deviation in the upstream head reading for a given discharge. When these limits are exceeded, an additional downstream head measurement is sometimes used to extend the measurement range of a flume, particularly for Parshall and cutthroat flumes, but at considerable loss of accuracy. Submergence also increases upstream channel depth, decreasing the upstream velocity, which may aggravate sedimentation problems. Long-throated flumes can tolerate high submergence in some cases. Trying to extend their measurement range with a downstream head measurement is not recommended. They can be designed to have submergence limits (modular limits) ranging from 65 to 95 percent, depending on discharge rate, shape, and exit channel energy conditions. For example, a flume discharging into a channel that is similar in size and shape to the approach channel can have submergence limits that calculate to exceed 82 to 95 percent for minimum to maximum flow rate, provided an expansion section is used, and from about 72 to 93 percent without an expansion section. The same flume, when discharging into a lake, may have submergence limits of only 65 to 80 percent, decreasing further to about 60 to 70 percent if there is no expansion section. Thus, some knowledge of the installation site is needed before a required head loss can be assigned. Visual determination of limiting submergence for most flumes can be difficult. However, for long-throated flumes, this condition is relatively easy to recognize. Several references offer guidelines in terms of standing diagonal wave locations to aid visual determination of flow submergence (Bos et al., 1991; Clemmens et al., 1993). In general, if the downstream hydraulic jump causes a frothy wave line across the channel that is at or beyond the end of the contracted throat section, the flume has not reached its limiting submergence-the modular limit. If the wave is on the throat, or no wave is visible, the flume is beyond its submergence limit, and the measurement would be invalid. 8-5
For long-throated flumes, painting lines projecting up the channel walls to denote the downstream end of the crest to aid visual distinction is suggested (Bos et al., 1991). Distinction in terms of wave location in Parshall flumes is not so clear. In the absence of visual observation in any of the flumes, automatic recording operations may need a second downstream head measurement if the opportunity for excessive backwater exists. This measurement would warn of invalid data. Some states have laws that require Parshall flumes by name for certain situations. Past designs for Parshall flumes tended to overuse submergence for economic savings with the only caveat that submergence should not exceed 95 percent. However, today, designing for this level of submergence is not considered good practice in view of accuracy loss and a hysteresis discontinuity in the submergence correction function described in the section on Parshall flumes in this chapter.
(2) If the control width is less than 50 percent, then 20 control widths of straight unobstructed approach are required. (3) If upstream flow exceeds critical velocity, a jump should be forced to occur. In this case, 30 measuring heads of straight unobstructed approach after the jump is completed should be provided. (4) If baffles are used to correct and smooth approach flow, then 10 measuring heads should be placed between the baffles and the measuring station. Approach velocities less than 1 foot per second (ft/s) encourage aquatic pests, insects, and sediment deposition, so the approach velocity should exceed 1 ft/s if at all practical. To prevent wave interference of head measurement, the Froude number of the approaching channel flow should be less than 0.5 for the full range of anticipated discharges and should not be exceeded over a distance of at least 30 times the measurement head before the structure. It is recommended that a check be made of the approach velocity condition by current meter measurements, especially when using baffles. In any case, approach condition should be verified visually. Visual inspection should be made for obvious boils and backflows and unstable surface conditions.
8-7
6. Workmanship
Flumes require accurate workmanship for satisfactory performance. Short flumes will provide reasonably accurate flow measurements if the standard dimensions are attained during construction. For accurate flow measurement, the flow surfaces must be correctly set or placed at the proper elevation, the crest must be properly leveled, and the walls must be properly plumbed. Although long-throated flumes can be computer recalibrated using as-built dimensions to correct for moderate form slipping or errors of construction, correcting for throat-section slope in the direction of flow is not always satisfactory. In any case, adequate care during construction is preferable. The modified broad-crested weir flume has only one critical flow surface, and it is level. Flumes should be set on a solid, watertight foundation to prevent leakage around and beneath the flume and prevent settlement or heaving. Collars or antiseep walls should be attached to either or both the upstream and downstream flanges of the flume and should extend well out into the channel banks and bottom to prevent bypass flow and foundation settlement caused by erosion. A stable foundation without significant settling or leakage must be secured at reasonable costs. The flumes can be built of wood, concrete, galvanized sheet metal, or other materials. Large flumes are usually constructed on the site, but smaller flumes may be purchased as complete flumes and placed in one piece. Others are provided in bolt-together pieces which are assembled onsite. Some of these flumes are made of lightweight materials, which are then made rigid and immobile by careful earth backfill or by placing concrete outside of the walls and beneath the bottom. When making a number of relatively small concrete flumes of the same size, use of portable and knockdown reusable forms is economical and practical. These forms require high quality design and workmanship. 8-8
Good construction practice should be used in placing footings, setting the forms, and pouring and tamping wall concrete to provide smooth surface finishes. Accuracy of the short flumes depends on correct flume dimensions, proper setting, and proper use. As flume size decreases, the influence of a small dimensional error becomes more prominent, and the importance of this care increases.
7. Head Measurements
The head is usually sensed either in the channel itself or in a stilling well located to one side of the channel. The stilling well is connected by a small pipe to the channel. Many methods can be used to detect the water surface in a stilling well or in the flume channel. Some methods exploit the electrical conductance of water and capacitance of immersed insulated wires. Sonic sensors depend on timing sound pulses reflected from the water surface. Measurement heads can also be determined with a variety of pressure sensing devices. The most frequently used methods are wall-mounted staff gages in the entrance section of the flume or in a stilling well or floatoperated recorders placed in a stilling well.
8-9
If head detection is in
Open channel Point gage Dipstick Not applicable Not applicable 0.013 0.023 > 0.050 0.066 0.033 Not applicable Stilling well 0.0015 0.003 0.013 0.016 0.023 Not required Not required 0.016 Commonly used for research Good for research/field use
Staff gage Pressure bulb + recorder Bubble gage + recorder Float-operated recorder Float totalizer attached to recorder
For concrete-lined canals, the gage can be mounted directly on the canal wall. The value for measuring head on the sloping walls of trapezoidal-shaped canals must be appropriately converted to vertical head values before entering the discharge tables. These tables are usually made for stilling well use or vertical gage applications. The sloping gage can be marked to read direct values or equivalent values of vertical head. Sometimes, sloping staffs are marked to display discharge directly, but the discharge gradations are not equally spaced. The gage may be mounted onto a vertical support for unlined canals. Most permanent gages are enameled steel, cast aluminum, or some type of plastic resin. Enameled linear scales marked in metric or English units are available from commercial sources. An example staff gage is shown on figure 8-4. Important flow rates can be noted on these scales by separate markings, allowing convenient adjustment of control gates to desired discharges without requiring tables. For convenience, the gages can be marked directly in discharge units rather than in measuring head units. 8-10
Figure 8-4 -- Typical staff gage for measuring head or water stage.
Connections that are not flush and/or have rough edges have different head losses depending on direction of flow in the connecting piping. This causes buildup or reduction of head in stilling wells compared to the actual head in the measurement device. The size of the stilling well depends on the method used to measure the head. The diameter, if circular shaped, ranges from a recommended minimum size of 4 in for hand-inserted dipsticks to 18 in to accommodate larger diameter floats. Wells may be much larger to provide access for cleaning or to make the reading of wall attached staff gages at sight angles at least as flat as 30 degrees. It is recommended that well walls have a 2-in clearance from floats and weights used with recorders. A stilling well may need to house the float and recorder system or other surface detecting equipment. The wells may need to be tall enough to provide convenient access to recorders for reference setting and maintenance. The wells may also need to be tall enough to keep counterbalance weights from interfering with float movement. Before making a measurement, the wells should be flushed with fresh water to be sure they are free of sediment, foreign material, or blockages, which could cause erroneous head readings. Recording equipment should be checked and serviced regularly. Cross-checks should be made between the staff gages, hook gages, plumb bobs, recorder values, and any other discharge indicators to expose system errors. Thus, even when using stilling wells, staff gages should still be used on the insidewalls of flumes for cross-checking. Further details on stilling wells can be found in chapter 6 and Bos (1989), Bos et al. (1991), and Brakensiek et al. (1979).
8-12
A stable and permanent surveying bench mark, such as a bronze cap placed in concrete, should be added in an acceptable location near the measuring structure. Its elevation should have been previously established relative to the sill elevation. More detailed information on zero-setting procedures is presented in Clemmens et al. (2001) and Bos et al. (1991).
Some confusion of terminology exists here. Some investigators would consider the ramp flume a broad-crested weir because the flow constriction is produced from a bottom transition alone, whereas a flume would depend to some extent on side convergence. Both long-throated flumes and broad-crested weirs can be accurately rated by analysis using fluid flow concepts. The energy principle, critical depth relationships, and boundary layer theory are combined when computer calibrating these flumes and weirs. Because of this close connection, this manual will consider and call both the long-throated flumes and broad-crested weirs longthroated measurement structures. Cost estimates for a large 930ft3/s ramp flume varied from about 45 to 60 percent of that for a Parshall flume in a retrofit situation. Clemmens and Replogle (1980) cited costs of onetenth to onethird of equivalent Parshall flumes for a small ramp-type, long-throated flume. Some of the cost differences between small and large structures result from the need for service roads, foundation differences, and repair of approach channel surfaces in retrofit designs. Long-throated flumes can be computer calibrated to within +2 percent plus head measurement error and have submergence limits up to 90 percent. Even when the listed submergence limits are near 70 percent, the absolute head loss or water surface drop through the long-throated flumes may be smaller than the older structures, depending on the particular design selection from among the many choices of shape. Short-throated flumes can measure free flow accurately in the range of +3 to +5 percent plus head measurement error and have submergence limits from 50 to 80 percent. Increased uncertainty occurs when using flow corrections to obtain discharge rates beyond submergence limits commonly up to 95 percent. However, Peck (1988) found large correction errors caused by hysteresis shifts of the downstream wave front at a submergence of 90 percent. Correction is frequently done above 90-percent submergence with Parshall flume measurements. Using submergence corrections commonly results in discharge errors ranging from 7 to +20 percent, and possibly much more, as differences in upstream and downstream measuring heads become small. With most flumes, close adherence to tolerances during construction is required to rely on empirical equations and calibrations provided for each specific short-throated flume. Dimensional errors and slippage of the forms frequently cause unacceptable errors that are difficult to resolve without laborious field calibrations. Field calibrations for submergence correction are very cumbersome and time consuming because of the usual project operational limitations, difficulties of controlling heads, and the need for long lag times for heads to settle to asymptotic levels. However, long-throated flumes can usually be computer recalibrated using asbuilt dimensions if form slippage has not caused crest slope in the direction of flow. Even then, crest correction may be practical and relatively inexpensive. The measured heads in the short-throated flumes do not always indicate system head loss. For example, the upstream measured head of a Parshall flume is located about one-third of the way into its converging crest section, and the water surface may have a considerable drawdown from the approach canal surface elevation. This factor makes size selection and crest elevation setting more complicated than for long-throated flumes that approximate existing channel dimensions and shape.
8-14
Because long-throated flumes have greater tolerance to submergence than short-form flumes and weirs, they can deliver more discharge without having to consider the effects of submergence, which usually requires observation of a downstream depth. For example, Parshall flumes require 3 to 4 times the absolute water surface fall through the structure for free-flow measurements than long-throated flumes (Bos et al., 1991). Long-throated flumes, with tolerances for high submergence ratios, require only one head measurement. They are considered to be more accurate and economical than, for example, extending Parshall flume measurement range by submerging up to comparable long-throated flume submergence limits and making corrections using two head measurements. Because long-throated flumes fit nicely into existing flow channels, they are convenient for making portable measurement devices. Portable long-throated devices for flow rates up to about 2 ft3/s are described in Bos et al. (1991), for trapezoidal and rectangular cross sections.
The S.I. tables are reproduced in Cheremisinoff et al. (1988). Statistically fitted equations in S.I. units that closely reproduce the computed tables are presented in Hoffman et al. (1991). The above references and this manual provide design and calibration tables for selecting and sizing long-throated structures from sets of predetermined, dimensioned, and precalibrated structures or from dimensionless design tables for some special structures. However, computer techniques are much preferred for all installations, designs, and calibrations for long-throated flumes. Thus, when practical, long-throated flumes should be designed using the WinFlume computer program (http://www.usbr.gov/pmts/hydraulics_lab/winflume/). Using restricted sets of dimensions reduces the capability of more exact custom fitting to shapes of existing channels, which can make it difficult to attain discharge range requirements. The need for computer techniques becomes much more important for large long-throated structures.
8-17
Table 8-2. Long-throated flume sizes and discharge ranges for lined trapezoidal canals (English units)ac
Canal Shape Side slope Z1 (1) 1.0 Bottom width, b1 (ft) (2) 1.0 Maximum canal depthb, d (ft) (3) 2.5
Range of Canal Capacities Qminc (ft3/s) (4) 1.9 4.2 4.8 5.6 6.2 5.6 6.2 6.8 7.4 8.2 5.0 6.4 7.6 6.4 7.6 8.9 10.1 11.4 8. 9. 11. 12. 13. 9. 11. 12. 13. 14. 17. Qmax (ft3/s) (5) 8d 16d 19 15 11 27d 40 33 27 22 19d 35 26 31d 64d 78 62 46 49d 82d 86 72 60 66d 108d 140d 160 140 98 Weir selection (table 8-3) (6) Ae Be Ce De Ee De Ee Fe Ge He Ie Je Ke Je Ke Le Me Ne Pe Qe Re Se Te Qe Re Se Te Ue Ve
Weir Dimensions Crest width, bc (ft) (7) 2.0 2.5 3.0 3.5 4.0 3.5 4.0 4.5 5.0 5.5 3.0 4.0 5.0 4.0 5.0 6.0 7.0 8.0 5.0 6.0 7.0 8.0 9.0 6.0 7.0 8.0 9.0 10.0 12.0 Sill height, p1 (ft) (8) 0.50 0.75 1.00 1.25 1.50 0.75 1.00 1.25 1.50 1.75 0.8 1.2 1.6 0.8 1.2 1.6 2.0 2.4 1.00 1.33 1.67 2.00 2.33 1.00 1.33 1.67 2.00 2.33 3.00 Minimum head loss, H a (ft) (9) 0.06 0.08 0.10 0.12 0.13 0.10 0.12 0.14 0.15 0.16 0.08 0.11 0.14 0.10 0.13 0.16 0.18 0.20 0.11 0.13 0.16 0.18 0.20 0.12 0.14 0.17 0.20 0.22 0.25
1.0
2.0
3.0
1.25
1.0
3.0
1.25
2.0
4.0
1.5
2.0
4.0
1.5
3.0
5.0
NOTES: LaH1max; Lb=2 to 3p1; x=La+Lb>2 to 3 H1max L>1.5 H1max d>1.2 h1max+p1 H>0.1H1 b Maximum recommended canal depth c Limited by sensitivity d Limited by Froude number; otherwise limited by canal depth e Calibrations developed with WinFlume and the preceding computer models.
Table 8-3. Rating equation parameters and ranges of application for flat-crested, long-throated flumes in lined trapezoidal canalsa
Q = K1(h1+K2)U
8-19
Table 8-4. Rating equation parameters and ranges of application for flat-crested, long-throated flumes with rectangular throat sections (see Figure 8-6).
q = K1(h1+K2)U where q is the unit discharge in cubic feet per second per foot of width of the throat. Q = qbc
Parameters K1 K2 U h1, range q, range H Parameters K1 K2 U h1, range q, range H Parameters K1 K2 U h1, range q, range H 0.35 bc 0.65 ft, L = 0.75 ft p1 = 0.25 ft p1 = 0.125 ft p1 = 3.996 0 1.612 0.06 0.46 0.04 1.15 0.04 p1 = 0.25 ft 3.662 0.008 1.643 0.15 1.0 0.18 3.2 0.07 p1 = 1.0 ft 3.125 0.017 1.621 0.3 3.0 0.48 19 0.25 3.610 0 1.581 0.06 0.48 0.04 1.14 0.06 3.126 0 1.526 0.05 0.5 0.03 1.08 0.19 0.65 bc 1.0 ft, L = 1.0 ft p1 = 0.5 ft p1 = 0.25 ft p1 = 3.696 0.004 1.617 0.08 0.7 0.07 2.1 0.06 p1 = 3.036 0 1.514 0.15 1.5 0.17 5.6 0.5 p1 = 2.999 0 1.521 0.3 3.0 0.48 16 0.85 3.385 0 1.562 0.8 0.7 0.07 1.95 0.10 3.089 0 1.518 0.08 0.8 0.07 1.8 0.26 p1 = 0.25 ft 3.686 0 1.598 0.1 0.9 0.09 3.1 0.07 1.0 bc 1.5 ft, L = 1.5 ft p1 = 0.5 ft p1 = 3.400 0 1.569 0.1 1.0 0.09 3.4 0.11 3.059 0 1.515 0.1 1.0 0.09 3.1 0.67 p1 = 3.027 0 1.519 0.2 2.04 0.26 9.24 0.63
1.5 bc 3.0 ft, L = 2.25 ft p1 = 0.5 ft p1 = 1.0 ft 3.375 0.011 1.625 0.15 1.5 0.17 6.6 0.13 3.19 0.009 1.587 0.15 1.5 0.17 6.1 0.2
3.0 bc 6.0 ft, L = 3.0 ft p1 = 1.0 ft p1 = 1.5 ft 3.169 0.013 1.605 0.22 1.93 0.29 9.28 0.22 3.167 0 1.557 0.21 1.98 0.29 9.26 0.29
bc 6.0 ft, L = 4.0 ft p1 = 1.5 ft p1 = 2.0 ft 3.150 0.016 1.575 0.3 2.6 0.48 14.2 0.33 3.105 0 1.563 0.3 2.64 0.48 14.2 0.40
La = h1max and Lb = 2 to 3 times p1 and La + Lb = 2 to 3 times h1max H = 0.1H1, or value listed, whichever is greater, for flumes discharging into a rectangular tailwater channel of the same width as the crest, bc H = 0.4H1, or value listed, whichever is greater, for flumes with an abrupt expansion into a tailwater channel wider than the crest width, bc
Table 8-5. Equation and flow range parameters for flat-crested, long-throated flumes in partially full circular conduits (K1 and K2 3 values are valid for units of feet and ft /s only).
p1/D 0.20 0.25 0.30 0.35 0.40 0.45 0.50 La/D 0.50 0.60 0.55 0.50 0.45 0.40 0.35 Lb/D 0.60 0.75 0.90 1.05 1.20 1.35 1.50 L/D 0.700 1.125 1.050 0.975 0.900 0.825 0.750 K1 4.176 3.970 3.780 3.641 3.507 3.378 3.251 K2 0.007 0.004 0 0 0 0 0 U 1.750 1.689 1.625 1.597 1.573 1.554 1.540 range of h1/D 0.080 - 0.43 0.070 - 0.60 0.070 - 0.55 0.065 - 0.50 0.060 - 0.45 0.055 - 0.40 0.050 - 0.35 range of Q/D5/2 0.056 - 0.980 0.048 - 1.689 0.050 - 1.434 0.046 - 1.202 0.042 - 0.991 0.037 - 0.807 0.032 - 0.640
2.5
Pregage distance, Lpg hmax Sill height = p1 Approach, La hmax Dimensionless sill height = p1/D Converging, Lcv = 3 p1 hmin = 0.07D hmax = [0.85 D - p1] Control, Lc 1.5 D p1 H = 0.1H1 for flumes with a 6:1 downstream transition H = 0.2H1 for flumes with a vertical drop downstream from the crest
h Q = D K1 1 + K 2 D
Note: The length values shown are minimum lengths in direction of flow, and may be increased 30 percent with only a slight change in calibration.
Note: These values represent minimum lengths in direction of flow, may be increased 30 percent with only slight change in calibration, and should be suitable for most applications. Besides selecting shape and size, the tables help to determine head-discharge characteristics, obtain proper measurement range, obtain sufficient sensitivity, meet the Froude number limit, and provide a final calibration. 8-20
The equation coefficients, exponents, and constants included in the tables were developed with the assumption of a known approach channel cross-sectional shape and area. However, any particular control section size and shape can be used with any approach section size and shape. But discharges must be adjusted with the approach velocity coefficient, Cv (Bos et al., 1991). The rating equations with use limits are given in design and selection tables that automatically limit the Froude number. However, if smaller approach areas are used, the designer must determine that the Froude number remains less than about 0.5. Frequently, the site conditions may call for flumes that would have dimensions beyond the ranges provided by the ratings in this chapter. To extend beyond these limits and for further information, refer to Bos et al. (1991), Clemmens et al. (1993), Ackers et al. (1978), and Bos (1989). The designer has the option of designing a flume shape or size not presented here by using the theoretically based computer program (Clemmens et al., 1987; 1993).
8-21
slopes as given in the first two columns. The third column lists recommended values of maximum canal depth, d, for each side-slope and bottom-width combination. The offering of many pre-computed sizes will aid in retrofitting older canal systems and yet not prevent the adoption of standard sized canals as proposed by other agencies and international bodies, such as the Natural Resources Conservation Service, U.S. Department of Agriculture (USDA), and the ICID. For each combination of bottom and side slope, several standard crest sill heights can be used (column 8 in table 8-2). Columns 4 and 5 give the limits on discharge for each canal-flume combination. These limits on canal capacity originate from three sources: (1) The Froude number, equation 2-25, in the approach channel, is limited to less than 0.5 to assure water surface stability. (2) The canal freeboard, Fb, upstream from the structure, should be greater than 20 percent of the upstream sill-referenced head, h1. In terms of canal depth, this limit is d>(p1 + 1.2h1max). (3) The sensitivity of the flume at maximum flow should be such that a 3/8-in change in the value of the sill-referenced head, h1, causes less than a 10-percent change in discharge. Also indicated in the last column of table 8-2 is a minimum head loss, H, that the structure must provide. Excessive downstream water levels may prevent this minimum head loss, which means that the structure exceeds its modular limit or submergence limit and no longer functions as an accurate measuring device. When flumes are placed in irrigation canals, the downstream channel is similar to the upstream channel, and the modular limit range for a flume with no expansion section of 72 to 93 percent for low flow to high flow is appropriate. The tables presented herein for long-throated flumes and broad-crested weirs are based on this assumption, except that the upper limit is conservatively reduced to 90 percent. Thus, the design head loss is either 0.1 h1 or the listed value for H, whichever is greater. For these tables, it was assumed that the weir was placed in a continuous channel with a constant cross section. Technically, this limit of submergence is based on the total energy drop through the structure, but the velocity head component is usually of the same order of magnitude upstream and downstream so that h may be satisfactorily substituted for H. Table 8-2 is primarily intended for the selection among these structures. It is also useful for the selection of canal sizes. The Froude number in the canal is automatically limited to 0.5. Selecting the smallest canal for a given capacity will give a reasonably efficient section. For instance, if the design capacity of the canal is to be 35 ft3/s, the smallest canal that can be incorporated with a measuring flume has b1 = 2 ft, z1 = 1.0, and d = 3 ft. Each standard flume can be used for a range of bottom widths because the change in flow area upstream from the structure causes only a small change in velocity of approach and a 8-22
corresponding small change in energy head. The width ranges have been selected so that the error in discharge caused by the change in flow area is less than 1 percent. This is a systematic error for any particular approach channel size, and the extent of this error varies with discharge. However, the width of the crest must match the table dimension value. A flume suitable for several of the listed canal bottom widths is also suitable for any intermediate width. For example, in table 8-2, structure Ee can be used in canals with bottom widths between 1 and 2 ft; for example, b1 = 1.25 ft. The user will need to determine the sill height to match bc, head loss, and maximum design discharge for these intermediate sizes. The rating equation coefficients and constants for the flumes are given in table 8-3 and will reproduce the values presented in the original calibration tables produced by computer modeling (Bos et al., 1991) to within about +1 percent. The original tables were computed using the following criteria and the symbols on figure 8-5: (1) Each flume has a constant bottom width, bc, and a sill height, p1, that varies with the canal dimensions. (2) The ramp length can be chosen such that it is between 2 and 3 times the sill height. The 3:1 ramp slope is preferable. (3) The gage is located a distance equal to at least maximum total head, H1max, upstream from the toe of the ramp. In addition, the gage should be located a distance of roughly 2 to 3 times H1max from the entrance to the throat. (4) The throat length should be at least 1.5 times the maximum expected sill referenced measured head, h1max, but should be within the limits indicated in table 8-2. (5) The canal depth must be greater than the sum of (p1 + h1max + Fb), where Fb is the freeboard requirement, which is roughly 0.2 times the sill referenced maximum measured head, h1max. Occasionally, a flume cannot be found from these design tables that will work satisfactorily. The user must then judge and select between several options; for example: (1) Find a new site for the structure with more vertical space. (2) Add to the canal wall height upstream from the site so that more backwater effect can be created. (3) Try one of the other shapes. (4) Use the design tables to interpolate and get a rating for an intermediate width, probably with some sacrifice in accuracy. (5) Produce a special design using the computer model.
8-23
Figure 8-6 -- Flow measurement structure for earthen channel with a rectangular control section. For earthen canals, the designer selects both structure flow width and a sill height and must be more aware of the other design considerations. For lined channel design, only the sill height must be selected. If the upstream sill-referenced head is not measured in a rectangular approach canal of this same width, but instead is measured in the upstream earthen section, then these tables require correction to the discharge, Q, for the change in the approach velocity. The tables and equations can also be used to determine the rating for side-contracted rectangular flumes. Procedures needed to handle and correct for change of velocity of approach are given in Bos (1989), Bos et al. (1991), and Clemmens et al. (1993). Throat lengths for side contractions appear to work best if they exceed about 2 times the throat width. The full-length structure of figure 8-6 can be simplified by deleting the diverging transition (downstream ramp) or the entire extended rectangular tailwater channel. These changes will increase the head loss across the structure and force energy dissipation to take place within the earthen canal section. The extended tailwater section of the structure may be deleted only if adequate riprap is provided and if the Froude number in the tailwater channel is less than 1.7 at maximum flow (Bos et al. 1991). The approach canal of figure 8-6 provides a known flow area and velocity of approach. The coefficients and constants for rating equations for the rectangular flumes given in table 8-4 assume that the approach section is rectangular and has the same width as the throat.
8-24
The rectangular measurement flume discharges nearly equal quantities of water over equal widths. The major differences are associated with the friction along the walls. Thus, the flow is nearly two-dimensional along the crest, so rating tables can provide the unit flow rate, q, in cubic feet per second per foot width of crest for each value of h1. This allows a wide variety of sizes for rectangular long-throated structures. For each width, bc, of the structure, an accurate rating table can be developed by multiplying the design table discharges by bc:
Q = b cq
(8-1)
The equation, coefficients, and exponents for a series of rectangular flat-crested, long-throated flumes given in table 8-4 were developed from computer modeled tables given in Bos et al. (1991). The equation will reproduce those computer-derived table values to within +1.5 percent. The equation coefficients and exponents are given for sets of p1 or crest heights. However, interpolation between crest heights gives reasonable results. Small groupings of structure widths were averaged to keep sidewall effect error to within 1 percent. Overall accuracy of rectangular long-throated flumes can be between 2 and +5 percent, depending on how accurately water levels are measured. Overall accuracy of +2 percent is possible but requires calibration by the computer program of Clemmens et al. (1993) and sensitive stilling well water level measurements. If the approach area, A1, is larger than that used to develop these rating design tables, either because of a higher sill or a wider approach channel, the ratings must be adjusted for Cv. To simplify this process, the discharge over the structure for a Cv value of 1.0 is given in the far right column of each grouping. This column is labeled p1 = infinity because that would cause the approach velocity of zero, and Cv would be 1.0. This scenario approximates a structure at the outlet of a reservoir or lake. The complete correction procedure is given in Bos (1989), Bos et al. (1991), and Clemmens et al. (1993). The design procedure for lined rectangular canals is relatively straightforward. It consists of selecting a table crest height, p1, that causes modular flow throughout the discharge range and provides sufficient freeboard at the maximum discharge. An appropriate width must be chosen for unlined canals. Several widths will usually work. Extremely wide, shallow flows are subject to measurement errors because of low head detection sensitivity. Extremely narrow, deep flows require long structures and large head losses. Because of the wide variety of shapes that can be encountered in earthen channels and in the range of discharges to be measured, determining the interrelated values of h1max, p1, and bc of the structure is complicated. Although this difficulty complicates the design process, it allows the designer greater flexibility and expands the applicability of the flumes. The following criteria should be considered by the designer: (1) The discharges to be measured (per foot of width) must be within the range of discharges shown in the table for the selected structure if the dimensions in the tables are to be used. (2) The needed or selected allowable combined measurement error should be checked and not exceeded. The allowable error may vary for different flow ranges (Bos et al., 1991; Clemmens et al., 1993). 8-25
(3) ) Sufficient head loss should be available across the structure at all flow rates. If there is an abrupt expansion (no downstream ramp) into a rectangular channel the same width as the crest, the head loss should be the greater of 0.1H1 or the value shown in table 8-4. If the downstream channel is wider than the crest, the head loss should be at least 0.4H1. (4) Placing a structure in the canal should not cause overtopping upstream. (5) A uniform, straight, and unobstructed approach channel section of 10 times the channel width should precede the structure. (6) The Froude number, as defined in chapter 3, should not exceed 0.5 for a distance of at least 30 times h1 upstream from the structure. Following these criteria will allow the designer to select a satisfactory structure that will operate as intended. For a rectangular long-throated flume in an earthen canal, the rectangular section need not extend 10 times its width upstream from the structure if a gradual taper is used to guide the flow into the rectangular section. For the structures given here, it is recommended that the rectangular section extend upstream from the head measurement location (gaging station) as shown on figure 8-6. It is also recommended that well-designed protective riprap be placed downstream from the structure for a distance of four times the maximum downstream channel flow depth, y2max (figure 8-6). A step should be provided at the downstream end of the structure just before the riprap section to avoid local erosion from floor jets. Sizing of riprap and filters is discussed by Bos (1989) and Bos et al. (1991). A freeboard criteria of 0.2 h1max has been used satisfactorily for lined channels. For unlined channels, it may be more appropriate to specify a maximum approach flow water depth, y1max. The downstream water depth, y2, needs to be checked and must not exceed the submergence or modular limit for both the minimum and maximum expected discharge. If the channel is rectangular or the length of the rectangular-throated flume downstream from the crest end is as on figure 86, then 0.1 H1 or the H value given at the bottom of table 8-4 can be used as the lower value of minimum required total head loss, H. If a shorter length in an earthen channel is used and the tailwater channel is significantly larger than the stilling basin would be, then considerably more head loss will probably be required. The designer should use the head loss value for the discharge into a lake or pool, H, = 0.4 H1. This value may represent a drastic difference in the value of head loss. The designer may decide to use the shortened structure and calculate the actual modular limit by use of the computer model (Bos et al., 1991). Another alternative is to build a prototype in the field and set the crest to the appropriate level by trial and error.
8-26
can be used in circular conduits. These flumes (figure 8-7) are usually placed in the conduit at a crest height from 0.2 to 0.5 times the pipe diameter in height. The open channel depth limit in the conduit is about 0.9 times the approach conduit diameter.
Figure 8-7 -- Long-throated flume in a partially filled circular conduit. General methods of computing calibrations for long-throated flumes in circular conduits and selected construction configurations were developed using the computer model described in Clemmens et al. (1993). The precalibrated selections given in table 8-5 are for average roughnesses of construction materials and are based on curve-fitted equations of computed discharge tables in English units for dimensions proportioned in terms of pipe diameter. Calibration equations for other pipe diameters can be approximated using Froude modeling relationships, which produce the following equation:
Q = discharge, ft3/s D = diameter of pipe, ft K1 = constant from table 8-5 K2 = constant from table 8-5 h1 = head measured from sill top (bottom of contracted section), ft U = Exponent
Precalibrated flumes represented in table 8-5 are subject to Froude scaling. These and all the long-throated flume shapes can be similarly scaled without using the computer model as long as all dimensions remain proportional. Small differences from direct computer results are to be expected because roughness of construction materials is not usually scaled. Smooth concrete roughness was used to develop the values in table 85. The calibration equations, coefficients, constants, and exponents for the equation from table 8-5 will usually produce calibrations within +3 percent of discharge, not counting the error of head measurement, for scaling ratios between 8-27
1:5 and 5:1. Scaling expansion by 10 tends to overemphasize roughness and will underpredict discharge by 5 to 10 percent. Accuracy within +2 percent requires individual computation of the constructed device using the constructed dimensions in the computer model of Clemmens et al. (1993). As with the other broad-crested weirs and long-throated flumes, the width of the flat crest or sill surface, bc, is one of the two most important dimensions in the flume. The other is the zero elevation of the head measuring device. For portable measurements, it is recommended to translocate the water surface to a small stilling well overhanging the crest at the head reference location. Thus, the translocated head in the stilling well is conveniently referenced to the crest without the necessity of surveyor leveling of the structure (Bos et al., 1991). The measuring head and crest elevation can both be measured by the same point gage. The upstream gage should be used only if it is accurately leveled or is part of a permanently installed flume. For example: A circular concrete culvert 4 ft in diameter and 20 ft long is to be converted into a measuring structure. The outlet ends in an overfall so that a minimum sill height of 0.2D is useable. Develop the calibration equation using table 8-5, and sketch the installation dimensions. Using equation 8-2 and table 8-5 gives:
Q = (D5/2)K1(h1/D + K2)U
or: Q = (4)5/2 4.13 (h1/4 + 0.004)1.736 or: Q = 132.2(h1/4 + 0.004)1.736 for an h1 range of: 0.08 D < h1 <0.65D or: 0.32 <h1 < 2.6 and a Q range of: 0.056 D5/2 < Q < 1.975D5/2 or: 1.792 < Q < 63.2 The modular or submergence limits should be checked and should not exceed 0.8h1 if a vertical drop exists at the end of the downstream crest and should not exceed 0.9h1 if a 1:6 horizontal sloping ramp downstream is added such as shown on figure 8-6. These modular limits are equivalent to minimum required head loss to measure flow of 0.2h1. All flow rates to be measured should be checked for exceeding the modular limit. A stilling well can be placed in the channel if it does not significantly obstruct flow or divert flow to a far bank and cause erosion. Placing the stilling well in the upstream channel often causes detrimental flow patterns that can affect the function of the flow measuring device, unless it is dug deep into the bank or placed a substantial distance upstream. Represented on figure 8-8 is a static pressure tube consisting of several 1/8-in-diameter holes drilled into 1-in polyvinylchloride pipe used as a head measurement pickup. These holes are 8-28
located about 2 ft from the end of the capped pipe so that flow separation around the end of the pipe is neutralized by the time the flow passes the pressure sensing holes. The water level sensed here is transmitted to the stilling well where the depth can be observed by any of the several methods discussed in section 7 of this chapter.
Figure 8-8 -- Layout scheme for portable long-throated measurement structures in partially full circular conduits. Note that the sensing holes are well above the floor of the channel, which should reduce sediment plugging. Also, note that the sensing pipe is clamped tightly to the wall of the culvert so that debris trapping is minimized. The area obstruction of the pipe crossing the sill control area is small and can be ignored.
(d) Constructing Portable Long-Throated Flumes for Circular and Semicircular Conduits
A 0.2D sill height is commonly selected for semicircular conduits. For either semicircular or complete pipes, the sloping ramp can be fabricated from sheet materials such as galvanized steel, stainless steel, aluminum, or marine plywood. A suggested method for layout of the necessary portion of an ellipse is illustrated on figure 8-8.
In the past, it was common to size and set flumes for 95-percent submergence to reduce approach flow depths 4 to 6 in. The 1976 second edition of this manual gives detailed examples of selecting size and setting crest elevation for free flow and intended submergence. Although correction methods for determining submerged discharge exist, designing flumes for submerged flow measurement is no longer considered good design practice because it compromises accuracy. For example, imprecision of head measurement increases discharge error by 4 to 20 percent over the primary free-flow accuracy of 3 to 5 percent. In addition, a recent study (Peck, 1988) found a 12-percent discontinuity in the submergence correction function for a 1-ft flume depending upon whether downstream measuring head results from a falling or rising water surface. Designing and setting Parshall flumes for submerged flow measurement is not usually recommended because less expensive, long-throated flumes can be designed that approach or exceed 90 percent submergence limits with a single upstream head measurement. Moreover, the absolute required drop in water surface is usually less for the long-throated flumes, particularly the modified broad-crested weir styles. Because so many Parshall flumes are currently in use, the remaining part of this section is concerned mainly with structural dimensions for checking existing flumes, equations for computing discharges, free-flow discharge tables for each size flume, plots for submerged discharge measurement corrections, and head loss curves for assessing upstream depth changes caused by downstream delivery depth changes. Care must be taken to construct Parshall flumes according to the structural dimensions given on figure 8-9. This factor becomes more important as size gets smaller. The portion of the flume downstream from the end of the converging section need not be constructed if the flume has been set for free flow where it is not expected to operate above submergence limit. This truncated version of the Parshall flume is sometimes referred to as the Montana flume. Submergence corrections or discharge cannot be determined for Montana flumes or other modified Parshall flumes because they do not include the part of the full Parshall flume where the submergence head, hb, was measured during calibration. Different size Parshall flumes are not geometrically proportional. For example, a dimension in the 12-ft flume cannot be assumed to be three times the corresponding dimension in the 4-ft flume. Each of the flumes on figure 8-9 is a standard device and has been calibrated for the range of discharges shown in the table. The flumes can reliably measure free-flow discharge to within "3 to "5 percent, plus head detection error, if standard dimensions are attained during construction, the flume is correctly set, and the flume is operated and maintained according to the recommended procedures.
8-30
Figure 8-9 -- Parshall flume dimensions -- sheet 1 of 2 (courtesy of U.S. Natural Resources Conservation Services).
Figure 8-9 -- Parshall flume dimensions -- sheet 2 of 2 (courtesy of U.S. Natural Resources Conservation Services).
Parshall flume sizes are designated by the throat width, W, and dimensions are available for flumes from the 1-in size for free flow of 0.03 ft3/s at 0.2 ft of measuring head up to the 50-ft size with 3,000 ft3/s at a head of 5.7 ft. The free-flow discharge range and dimensions for Parshall flumes are given on figure 8-9. The minimum flows in this table up to the 1-ft-size flume are for a head of 0.2 ft because measuring at smaller heads results in imprecision of head measurement and surface tension effects. The remaining discharge limits are based on the range of the calibration data and practical size considerations.
8-31
Q = Chan (8-3)
where:
Q = discharge (ft3/s) C and n for each size are given in table 8-6
Head versus discharge is given in tables A8-7 through A8-21 for all sizes (see appendix). Table 8-6 Coefficients (C) and exponents (n) for Parshall flumes for equation 8-3 Throat width 1 in 2 in 3 in 6 in 9 in 1 ft 2 ft 3 ft 4 ft 5 ft 6 ft 7 ft 8 ft 10 ft 12 ft 15 ft 20 ft 25 ft 30 ft 40 ft 50 ft Coefficient (C) 0.338 0.676 0.992 2.06 3.07 3.95 8.00 12.00 16.00 20.00 24.00 28.00 32.00 39.38 46.75 57.81 76.25 94.69 113.13 150.00 186.88 Exponent (n) 1.55 1.55 1.55 1.58 1.53 1.55 1.55 1.57 1.58 1.59 1.59 1.60 1.61 1.60 1.60 1.60 1.60 1.60 1.60 1.60 1.60
Figure 8-10 -- Rate of submerged flow through a 1-in Parshall flume (Robinson, 1957).
Figure 8-11 -- Rate of submerged flow through a 2-in Parshall flume (Robinson, 1957).
Figure 8-12 -- Rate of submerged flow through a 3-in Parshall flume (Robinson, 1957).
Figure 8-13 -- Relationship of hc and hb gages for 1-, 2-, and 3-in Parshall flumes for submergence greater than 50 percent (Robinson, 1957). In a 3-in flume, assume ha of 0.20 ft and the downstream head measured at the hc gage is 0.19 ft. To determine the discharge, turn to the curve on figure 8-13, which shows the relationship of hc to hb. For a value of hc equal to 0.19, hb is found to be 0.17. The submergence, hb/ha = 0.17/0.20 = 0.85 or 85 percent. Enter figure 8-12 with the value of the upstream head, ha, of 0.20 and move horizontally to the right to the vertical line for hb/ha of 85 percent. This intersection point lies about seven-tenths of the distance from the curved discharge line for 0.06 ft3/s, toward the 0.07ft3/s line. The interpolated discharge value is 0.067 ft3/s. This rate of flow for submerged conditions is considerably less than the free-flow discharge value of 0.082 ft3/s for ha of 0.20 ft. As mentioned previously in section 7 of this chapter, correcting for submergences greater than 90 percent does not provide reliable accuracy.
8-35
Figure 8-14 -- Diagram of determining rate of submerged flow for a 6-in Parshall flume (courtesy of U.S. Natural Resources Conservation Service).
Figure 8-15 -- Diagram for determining rate of submerged flow for a 9-in Parshall flume (courtesy of U.S. Natural Resources Conservation Service).
Figure 8-16 -- Diagram for determining correction to be subtracted from free discharge to obtain rate of submerged flow for 1- through 8-ft Parshall flumes. Submergence correction values for 1- to 8-ft flumes are obtained from figure 8-16, but the procedures contained in the note in the figure must be followed. 8-36
These procedures state that values read from the curve are multiplied by the M values listed in the table on figure 8-16 for each size to obtain the product or correction to subtract from the free discharge values. For example, assume that submerged flow occurs in a 3-ft flume where ha is 2.10 ft and hb is 1.89 ft. The submergence ratio, 1.89 divided by 2.10, is 0.90, or 90-percent submergence. The free-flow discharge for a 3-ft flume with ha of 2.10 is found from table A8-12 to be 38.4 ft3/s. On figure 8-16, ha is 2.10 and submergence is 90 percent: a correction of 3.5 ft3/s. However, this correction is only for a 1-ft flume. For a 3-ft flume, the correction must be multiplied by 2.4 (from tabulation on figure 8-16) to get the total correction of 8.4 ft3/s. The corrected submerged discharge is, therefore, 38.4 minus 8.4, or 30.0 ft3/s. As mentioned previously in section 7 of this chapter, correcting for submergences greater than 90 percent does not provide reliable accuracy.
Figure 8-17 -- Diagram for determining correction to be subtracted from free discharge flow to obtain submerged flow discharges through 10- to 50-ft Parshall flumes (Parshall 1953). The correction values, indicated along the base of the diagram on figure 817, give the number of cubic feet per second to be subtracted for each 10 ft of crest width, W. To aid in determining the multi plying factor, a tabulation has been incorporated on figure 8-17. Thus, to determine the discharge for submerged flow through a 20ft flume when ha is 3.25 ft and hb is 3.06 ft, first determine the submergence ratio:
hb = 0.941 = 94.1% ha
Enter at the left side of the diagram of figure 8-17, and at ha equals 3.25, project a horizontal line to intersect the 94-percent line, then continue on to one-tenth of the distance between the 94- and 95per-cent lines. Vertically below this point on the horizontal scale is the correction value, 56 ft3/s. For a 20-ft flume, the multiplying factor is 2.0 (from tabulation on figure 8-17), and the total correction is: 8-37
2.0 x 56 = 112 ft3/s The free discharge value from table A8-16 for ha of 3.25 is about 503 ft3/s. Therefore, the submerged flow is 503 minus 112, or 391 ft3/s. As mentioned previously in section 7 of this chapter, correcting for submergences greater than 90 percent does not provide reliable accuracy.
Figure 8-18 -- Head loss through 10- to 50-ft Parshall flumes (Parshall 1953).
8-38
Figure 8-19 -- Head loss through 1- to 8-ft Parshall flumes (courtesy of U.S. Natural Resources Conservation Service.
8-39
Web Resources
Preface: The information provided below is intended for use with existing Parshall flumes operating in the submerged-flow correction zone. If you are contemplating construction of a new Parshall flume, you are strongly urged to consider a long-throated flume. Information about long-throated flumes is available at www.usbr.gov/wrrl/winflume
Figures 8-16 and 8-17 in the Water Measurement Manual, 3rd Edition (Chapter 8, Section 10), provide a means for correcting free-flow discharges through Parshall flumes to account for the effect of submergence. Figure 8-16 is for flumes of 1-ft width, and includes multiplying factors for use with flumes of 2- to 8-ft width. Figure 8-17 is for flumes of 10-ft width, again with multiplying factors for larger flumes up to 50-ft width, and can be easily converted to a single equation:
DQ = 0.000132ha2.123e9.284S
where e is the base of natural logarithms, 2.7183. This equation yields smaller discharge reductions and does not have the non-linear character of Parshall's nomograph (Fig. 8-16). Converting Figure 8-16 to a tractable equation would be a tedious exercise. Also, Peck's more detailed experiments on 1-ft flumes indicate less discharge reduction due to submergence than do Parshall's limited data, making the value of such an effort questionable. More detailed physical testing is needed to extend Peck's data for use on 2- to 8-ft wide flumes. 8-40
However, in the interim, it is reasonable to use Peck's equation for 1-ft wide flumes and the multiplying factors shown on Figure 8-16 to obtain discharge corrections for 2- to 8-ft wide flumes, with one caveat. Peck's equation is only valid for flow conditions on the right side of the discontinuity that he observed in submerged flow rating curves (i.e., submergences less than about 85 to 90 percent). (Note: Peck has an equation applicable to the left side of the discontinuity, but procedures for defining the exact point of discontinuity are not well defined.) Thus, for flumes of 1- to 8-ft width the discharge reduction in ft3/s can be computed using:
DQ = M(0.000132 ha2.123e9.284S )
where M is a multiplying factor that varies as follows:
Multiplying Factor, M 1.0 1.4 1.8 2.4 3.1 3.7 4.3 4.9 5.4
11. Bibliography
Ackers, P., W.R. White, J.A. Perkins, and A.J.M. Harrison. Weirs and Flumes for Flow Measurement. John Wiley & Sons, New York, 327 pp, 1978. American Society of Mechanical Engineers. Fluid Meters, Their Theory and Application. 6th edition revised. Report of American Society of Mechanical Engineers Research Committee on Fluid Meters, H.S. Bean, (ed.), American Society of Mechanical Engineers, New York, 202 pp., 1983. Bos, M.G. (ed.). Discharge Measurement Structures. Third edition revised. Publication 20. International Institute for Land Reclamation and Improvement, PO Box 45, 6700 AA Wageningen, The Netherlands, 401 pp., 1989.
8-41
Bos, M.G., J.A. Replogle, and A.J. Clemmens. Flow Measuring Flumes for Open Channel Systems. American Society of Agricultural Engineers. Republication of book by same title, originally by John Wiley & Sons, New York, 1984, 321 pp., 1991. Brakensiek, D.L., H.B. Osborn, and W.R. Rawls (coordinators/eds.). Field Manual for Research in Agricultural Hydrology. Agricultural Handbook 224, U.S. Department of Agriculture, U.S. Government Printing Office, Washington, DC, 547 pp., 1979. Cheremisinoff, P.N., N.P. Cheremisinoff, and Su Ling Cheng (eds.). Handbook of Civil Engineering Practice 2CHydraulics/ Mechanics. Technomic Publishing Company, Inc., Lancaster, Pennsylvania, 780 pp., 1988. Clemmens, A.J., and J.A. Replogle. Constructing Simple Measuring Flumes for Irrigation Canals. USDA Farmers Bulletin No. 2268, U.S. Department of Agriculture, 13 pp., 1980. Clemmens, A.J., J.A. Replogle, and M.G. Bos. FLUME: A Computer Model for Estimating Flow Through Long-Throated Measuring Flumes. USDA Agricultural Research Service Publication, ARS-57, 68 pp., 1987. Clemmens, A.J., M.G. Bos, and J.A. Replogle. FLUME: Design and Calibration of LongThroated Measuring Flumes. Version 3.0. International Institute for Land Reclamation and Improvement, PO Box 45, 6700 AA Wageningen, The Netherlands, Publication 54 (with software), 1993. Clemmens, A.J., T.L. Wahl, M.G. Bos, and J.A. Replogle, Water Measurement with Flumes and Weirs, ILRI Publication 58, International Institute for Land Reclamation and Improvement, PO Box 45, 6700 AA Wageningen, The Netherlands, 2001. Dodge, R.A. "Ramp Flume Model Study-Progress Summary," GR-8-14, Bureau of Reclamation. Denver, Colorado, 1983. Gwinn, W.R. "Calibration of Walnut Gulch Supercritical Flumes." Journal of the Hydraulics Division, American Society of Civil Engineers, 96(HY8)1681-1689, 1970. Gwinn, W.R., and D.A. Parsons. "Discharge Equations for HS, H, and HL Flumes." In Journal of the Hydraulics Division, American Society of Civil Engineers. Volume 102:HY1, pp. 7388. Discussion: Volume 102:HY11, pp. 1704-1706. Closure: Volume 103:Hy7, p. 809, 1976. Hoffman, G.J., T.A. Howell, and K.H. Solomon (eds.). Management of Farm Irrigation Systems. American Society of Agricultural Engineers, St Joseph, Michigan, 1,040 pp., 1991. Kulin, G., and P.R. Compton. "A Guide to Methods and Standards for the Measurement of Water Flow." National Bureau of Standards, Special Publication 421, 1975.
8-42
Parshall, R.L. Improving the Distribution of Water to Farmers by Use of the Parshall Measuring Flume. Soil Conservation Service, Bulletin 488, U.S. Department of Agriculture and Colorado Agricultural Experiment Station, Colorado A&M College, Fort Collins, Colorado, 1945. ____________. Parshall Flumes of Large Size. Bulletin 426-A (reprint of Bulletin 386), Colorado Agricultural Experiment Station, Colorado State University, Fort Collins, Colorado, 1953. Peck, H. "Submerged Flows in Parshall Flumes." Proceedings, National Conference, Hydraulics Division of the American Society of Civil Engineers, American Society of Civil Engineers, Colorado Springs, Colorado, 1988. Replogle, J.A. "Critical Flow Flumes with Complex Cross Sections." In Irrigation and Drainage in an Age of Competition for Resources. Specialty Conference Proceedings, American Society of Civil Engineers, pp. 366-388, 1975. Replogle, J.A., A.J. Clemmens, and M.G. Bos. "Measuring Irrigation Water," chapter 10, pp. 313-370. In Management of Farm Irrigation Systems. Hoffman, G., T.A. Howell, and K.H. Solomon (eds.), American Society of Agricultural Engineers, Monograph, St. Joseph, Michigan, 1991. Robinson, A.R. Parshall Measuring Flumes of Small Sizes. Technical Bulletin No. 61, Agricultural Experiment Station, Colorado State University, Fort Collins, Colorado, 1957. Robinson A.R., and A.R. Chamberlain. "Trapezoidal Flumes for Open Channel Flow Measurements." Transactions, American Society of Agricultural Engineers, vol. 3 (No. 2):120124,128, 1960. Skogerboe, G.V., R.S. Bennett, and W.R. Walker. "Generalized Discharge Relations for Cutthroat Flumes." Journal of the Irrigation and Drainage Division, American Society of Civil Engineers, vol. 98 No. IR4, pp. 569-583, 1972. U.S. Department of Agriculture, Soil Conservation Service. "Measurement of Irrigation Water." SCS National Engineering Handbook, Section 15CIrrigation, chapter 9, pp. 1-72, 1962. Wahl, T.L., A.J. Clemmens, J.A. Replogle, and M.G. Bos, "WinFlume Windows-Based Software for the Design of Long-Throated Measuring Flumes". Fourth Decennial National Irrigation Symposium, American Society of Agricultural Engineers, Nov. 14-16, 2000, Phoenix, AZ. http://www.usbr.gov/pmts/hydraulics_lab/winflume/ Wells, E.A., and H.B. Gotaas. "Design of Venturi Flumes in Circular Conduits." Transactions of the American Society of Civil Engineers, vol. 123, pp. 749-771, 1958.
8-43
9-1
Figure 9-1 -- Submerged-orifice measurement structure viewed from upstream (refer to table 9-1 for dimensions). Table 9-1. Recommended box sizes and dimensions for a submerged orifice Size of orifice Height of structure, B (ft) Width of head Length, Width, wall, A E W (ft) (ft) (ft) Length of downstream wing wall, C (ft)
9-2
(14) The cross-sectional area of the water prism 20 to 30 ft upstream from the orifice should be at least eight times the cross-sectional area of the orifice. (15) The selected type of head measuring device must be compatible with required project accuracy and the amount of head loss that is acceptable. If all these requirements are satisfied, then the effective discharge coefficient is good to +/-2 percent. However, the accuracy of discharge measurement depends strongly on the secondary head measurement system selected and the magnitude of h. Chapter 8 contains error values for different head measurement systems.
Q = discharge (ft3/s) Cc = coefficient of contraction Cvf = coefficient of velocity caused by friction loss Cva = coefficient to account for exclusion of approach velocity head from the equation A = the area of the orifice (ft2) g = acceleration caused by gravity (ft/s2) h1 = upstream head (ft) h2 = downstream head (ft)
The coefficient of contraction, Cc, accounts for the flow area reduction of the jet caused by the flow curving and springing from the orifice edges. The coefficient Cvf accounts for the velocity distribution and friction loss. The product, CcCvf, is sometimes called the coefficient of discharge, Cd. The coefficient Cva accounts for using the water head only and does not fully account for the velocity head of approach. This coefficient is near unity if all the requirements of section 4 are met. The effective discharge coefficient, Cd, is the product CcCvfCva, which has been determined experimentally to be 0.61 for rectangular irrigation weirs. The coefficient of contraction has the most influence on the effective coefficient discharge. Because Cc must approach unity as velocity approaches zero, its value will increase rapidly after reaching some low velocity. Thus, the equation should not be used for heads less than 0.2 ft even with very precise head measuring devices. The difference between upstream and downstream heads or water surface elevations is sometimes called the differential head, and equation 9-1a can be rewritten as:
Q = Cd A 2 g h
(9-1b)
9-4
where: h = h1 - h2, differential head Cd = 0.61, as determined experimentally. The discharge, when velocity of approach is negligible, may be computed using equation 9-1b. Table A9-21 was prepared for orifice areas from 0.25 to 2.0 ft2.
1
The prefix "A" denotes tables that are located in the appendix.
To avoid accumulations of sediment on the upstream side of the orifice, the bottom contraction may need to be suppressed by placing the lower side of the orifice at canal grade. In occasional instances, use of orifices with both bottom and side contractions suppressed may be necessary. For rectangular submerged orifices having partially suppressed perimeter contraction and negligible velocity of approach assured by providing an approach area at least 8 times larger than the orifice opening, the approximate discharge may be computed by:
Qs = 0.61(1 + 0.15r) A 2 gh
where:
Qs = discharge of the suppressed orifice in ft3/s, velocity of approach neglected r = ratio of the suppressed portion of the perimeter of the orifice to the total perimeter
The variables h, A, and g have the same significance as in equation 9-1b. The term in the parentheses can be thought of as a factor that adjusts the fully contracted effective coefficient of discharge used in equation 9-1b in terms of amount of perimeter with suppressed contraction. This method is expected to produce a coefficient correct to within about +/-3.0 percent. As a temporary estimating procedure, this method can be used to estimate discharge when sediment deposits are present in the approach to an orifice that was meant to be fully contracted. If the deposits were similar in effect to a smooth invert at the bottom of the orifice, the correction would be good. However, the accuracy of the estimated correction is usually in doubt because of the shape, depth, and location of the deposits. Best practice would require removing the sediment immediately rather than making the discharge adjustment. Equation 9-2 can be used for sluice gates when they are in effect bottom and/or side suppressed rectangular orifices with variable opening area. Table A9-3 gives discharge versus head for orifices that are both bottom and side suppressed for orifice areas of 2 ft2 to 125 ft2. Other more exact and complex approaches can be used for determining discharge with sluice gates. These approaches are discussed by Bos (1989), who states that equation 9-2 agrees closely to relationships developed by Henry (1950) and Franke (1968).
To account for excess velocity of approach, the approach velocity head is frequently added to the differential head under the radical assuming that the effective coefficient of discharge does not change. However, in equation 9-1b, this correction assumes that all the correction is accounted for by an approach velocity head term alone. However, this procedure only constitutes a partial correction. The factors that cause excess velocity of approach also cause changes in the contraction and head loss. Thus, the effective discharge coefficient changes by some undefined amount. It is better to find the cause of excess velocity, and if operation changes or maintenance cannot remedy the problem, then a replacement device may be required. Orifices can be calibrated for velocity of approach effects by comparing against another device. This comparison would require measurements at given discharges at several upstream and downstream heads. The cost of these measurements most likely would exceed the cost of a replacement measuring device.
9-7
Figure 9-3 -- A single-barrel CHO turnout. The CHO turnout consists of a short entrance channel leading to a headwall containing one or more gate-controlled openings, a head measurement stilling basin section, and a downstream headwall with one or more gate-controlled barrels that release the flow into the delivery channel (figure 9-4). The rate of flow is measured by using the principle that a submerged orifice of a given size operating under a specific differential head will always pass the same known quantity of water. The upstream gate or gates serve as orifices. The orifice area can be increased or decreased by adjusting the upstream gate or gates. Usually, the head differential is maintained at a constant value, usually 0.20 ft (h on figure 9-4) measured by staff gages or stilling wells located upstream and downstream from the orifice gate headwall.
Figure 9-4 -- Schematic view of a single-barrel CHO turnout with a horizontal inlet channel.
9-8
To set a given flow, the opening of the orifice for the desired discharge is obtained from discharge tables (tables A9-4 and A9-5 for the older 20- and 10-ft3/s sizes). With the upstream gates set at this opening, the downstream gates are adjusted until the differential head across the orifice as measured by the staff gages or stilling wells is at the required constant head (usually 0.20 ft). The discharge will then be at the desired value. Two sizes of orifice gates, 24 by 18 in and 30 by 24 in, have been used extensively in the past. Both sizes are provided in single-barrel and double-barrel designs. The capacity of the singlebarrel 24- by 18-in turnout is 5.0 ft3/s. The capacity of the single-barrel 30 by 24-in turnout is 10 ft3/s. Double-barrel installations have twice the capacity of the single-barrel ones. Newer designs (Aisenbrey et al., 1978) provide standard CHO turnouts for discharges of 2-,4-, 6-, 9-, 12-, 15-, 18-, 24-, and 30-ft3/s with corresponding opening widths of 1.5, 1.5, 2.0, 2.5, 2.5, 3.0, 3.5, 4.0, 4.0 ft. The gate sizes for these turnouts vary from 18 to 48 in. Table A9-6 gives discharge versus gate opening for these turnout sizes with a differential head of 0.2 ft.
For maximum capacities of 10 ft3/s and less, the length of gate basin should be at least 2.25 times the maximum gate opening or 1.75 times the gate support wall opening, whichever is greater. However, no basin length should be less than 3.5 ft. For capacities between 10 ft3/s and 30 ft3/s, the gate basin length should be at least 2.75 times the maximum gate opening. The bottom of the gate basin should be level. The gate opening should be less than or equal to 0.8 times the wall gate support wall opening. 9-9
The distance from the gate lip to the top of the gate support wall opening should be at least equal to the wall thickness. The approach flow submergence above the top of the opening should be 1.78 times the velocity head plus 0.25 ft. The set head differential should be at least 0.2 ft.
An important detail of the Reclamation orifice gate design is a 1-1/2- by 1-1/2-in angle iron brace projecting upstream on the face. The projecting leg of angle iron is located 1-3/4 in from the gate lip. Some of the smaller gates were built without this brace and were field calibrated with weirs. They were found to have an effective coefficient of 0.65. When this bracing is missing, equation 9-1b and this lower coefficient must be used to calculate discharges or tables. Colorado State University (CSU) tests (Kruse, 1965) determined that the effective discharge coefficient is about 0.65 for the normal operation where the depth upstream from the turnout is 2.5 or more times the maximum gate opening. This coefficient is the same value that Reclamation determined for no angle iron bracing at the bottom of the upstream gate face. CSU also investigated the effects of changes in upstream and downstream water levels, sediment deposits, plugging of the orifice gate with weeds and debris, and approach flow conditions. For discharges larger than about 30 ft3/s, special structures involving multiple gates and barrels are designed for the particular site and flow requirements.
9-10
Figure 9-5 -- Schematic view of a CHO turnout with a sloping inlet channel and with piezometers and stilling wells.
Choking caused by weeds that become lodged within the measuring orifice can be serious. Moreover, choking can be difficult to detect when silty water is flowing because the orifice cannot be seen. The principal cause of choking is the presence of waterlogged weeds that catch in the gate opening. These weeds may trap other particles and eventually plug the turnout. The measuring accuracy of CHO turnouts is greatly reduced by the presence of even a few weeds. Care must be taken to ensure that the orifice and the area upstream from the orifice are kept completely clear of weeds and other debris. Trashscreens or trashracks are sometimes placed at the inlet to the CHO turnout.
9-12
Figure 9-6 -- Baffles to reduce water surface fluctuations at staff gages in CHO turnouts.
Figure 9-7 -- Gated orifice check structure used to maintain upstream water surface levels and to measure rates of flow in the Courtland Canal, Nebraska.
9-13
The coefficients of discharge that should be used to compute the rate of flow are difficult to determine analytically because of different degrees of suppression at the bottom and sides and between the orifice openings. Computed discharge tables are ordinarily provided for each structure, but usually a statement is included that a field rating is necessary to ensure accurate results. In general, the recommended practice is that field ratings be made by current meter data and that discharge curves be prepared. For maximum potential accuracy, care must be exercised to prevent either excessively small gate openings or small differential head readings that cause large errors of precision of head or gate opening effects on discharge measurement.
Figure 9-8 -- Diagram of radial gate showing calibration variables. The general equation for flow through an undershot gate can be derived from the Bernoulli equation and expressed as:
Q = Cd G o B
2 gH
(9-3)
9-14
where:
Q = discharge (gate flow) Cd = coefficient of discharge Go = vertical gate opening B = gate width g = gravitational constant H = a head term
The head term, H, in the above equation can be either the upstream depth, Yu, or the differential head across the gate, Yu - Yd (see figure 98). When differential head is used, equation 9-3 becomes the well-known "orifice" equation. The development of the coefficient of discharge, Cd, depends on the definition of the head term as well as the various other parameters that affect gate flow. Cd has been predicted using a number of different methods, but most of these methods have limited application and accuracy. In 1983, a research program at Reclamation's Hydraulics Laboratory developed gate flow algorithms that represent the complete discharge characteristics for canal radial gate check structures. These algorithms are a complex set of equations that cover the range of water levels and gate geometry normally encountered at canal check structures. When applied correctly, they can be as accurate as any canal flow measurement device or procedure. The main disadvantages to using these algorithms are their complexity and the requirement to accurately measure two water levels, Yu and Yd, and the gate position, Go. Additionally, sedimentation or check structure subsidence can change gate flow characteristics at existing structures and require recalibration over time. A computer program has been developed to solve the radial gate flow algorithms. Program RADGAT executes on a personal computer to calculate either flow or gate position at a canal radial gate check structure. The user enters structure dimensions such as gate width, pinion height, gate radius, pier width (between gates), invert elevations, canal bottom widths and side slopes, and head loss coefficients for open transitions and siphons. These physical proper-ties are saved in a data file so they need not be reentered for successive program execution. Then, the user enters upstream and downstream water depths and has the option either to compute discharge for a given gate opening or compute gate opening for a given discharge. RADGAT can also produce rating tables of flow versus gate opening for a range of upstream and downstream depths. Buyalski (1983) contains detailed results from the research program and explanation of the discharge algorithms. It also contains the original version of program RADGAT developed for main-frame computer application. The personal computer version of RADGAT may be obtained through Reclamation's Water Resources Research Laboratory in Denver, Colorado.
9-15
Figure 9-9 -- Typical meter gate installation. Meter gates are usually purchased from commercial suppliers who furnish discharge tables for their product. Generally, the tables are reasonably accurate. In some instances, errors of 18 percent or more have been found. A number of characteristics of meter gates influence their performance, particularly when they are operated at openings larger than 50 percent or the upstream submergence above the crown of the pipe is less than the inside pipe diameter. The discharge table being used should be checked to ensure that it applies to the brand and type of gate being used. Tables for round-bottom gates must not be used for square-bottom gates and vice versa. Gate settings must be made and read accurately, which requires that the gate position indicators be in good condition and show the true openings. The stilling wells should be periodically flushed to make sure they are operating properly and are free of obstructions and silt. Staff gages or scales should also be checked to be sure they have been secured in the proper zero position. Weeds, trash, and sediment must be removed from the approach to the gates because they can cause flow disturbances that result in erroneous head differential readings. This requirement is particularly important along the wing walls because these walls have more effect upon the flow than does the alignment of the bottom. The approach effects are particularly important at gate openings greater than 50 percent. 9-16
Low head wall submergence over the meter gate entrance can also result in discharge errors, particularly at gate openings greater than 75 percent. Considerable error results when the head is less than one pipe diameter above the top of the pipe. Sufficient submergence must also occur at the downstream end of the conduit to ensure that the conduit flows full and that a readable water surface is present in the downstream stilling well, which will usually require at least 1 ft of water depth above the pipe crown. This amount of submergence will normally prevent scour damage downstream in earthen ditches. Large errors in discharge determination can be introduced if the differential head (difference in water surface elevation between the two stilling wells) is small. For example, in reading the two water surface elevations in the stilling wells, an error of 0.01 ft could be made in each reading, giving a possible value of 0.10 ft for a true differential head of 0.08 ft. For a true discharge of 1.10 ft3/s through an 18-in meter gate open 5 in, the difference in the indicated discharge would be about 0.12 ft3/s, an error of about 11 percent. If the gate opening was reduced to 2 in, and the upstream pool could be allowed to rise to pass the same discharge, the differential head would be 0.40 ft, and the same head-reading error of 0.02 ft would indicate a change of only 0.03 ft3/s. The error in discharge determination would be reduced from about 11 percent to less than 3 percent. The head in the downstream measuring well can vary widely depending upon the longitudinal and lateral location of the pressure tap in the pipe. Placing the pressure tap of the downstream measuring well 12 in from the gate is a special case requiring special calibration for each size gate unless the maximum gate opening is limited. A better location for the downstream piezometer would be at a distance D/3, measured from the downstream face of the gate. The pressure gradeline here is lower and flatter. Minor variations in piezometer locations would not result in major measuring errors, and the measured head differential would be greater. However, if the piezometer is moved to this point, the meter must be recalibrated because the manufacturer's published tables will not apply. Laboratory tests have been conducted on square-bottom, flat-leaf meter gates to determine the coefficient of discharge, Cd, for a pressure tap located at a distance D/3 downstream from the gate (Ball, 1961). This curve, shown on figure 9-10, is valid for all sizes of square-bottom, flatleaf meter gates under the following standard conditions:
Figure 9-10 -- Coefficient of discharge curve for meter gates with downstream pressure tap at D/3.
9-17
(1) An approach channel floor sloping upward, 2 to 1, toward the gate, with the downstream end of the floor a distance 0.17D below the pipe entrance invert. (2) Flaring entrance walls, 8 to 1, starting a distance D/4 from the edges of the gate frame. (3) Zero gate openings set when the bottom of the leaf is at the invert of the entrance. (4) Upstream submergence greater than D. (5) The downstream end of the pipe submerged to make the pipe flow full. It should be noted that the coefficient Cd is used with A, which is the area of the pipe and not the gate opening. Discharges may be computed from this equation with an accuracy of +/-2.5 percent. The degree of downstream submergence does not affect the accuracy of the meter if water rises sufficiently in the downstream well to obtain an accurate reading and the pipe runs full at the outlet.
15. Bibliography
Aisenbrey A.J., Jr, R.B. Hayes, H.J. Warren, D.L. Winsett, and R.B. Young, Design of Small Canal Structures, Bureau of Reclamation, Denver, CO, 1978. Ball, J.W., "Flow Characteristics and Limitation of Screw-Lift Vertical Metergates," Hydraulic Laboratory Report No. HYD-471, Bureau of Reclamation, Denver, CO, March 15, 1961. Blackwell, B.T., "Calibration of the Constant-Head Orifice Turnout1:2 Scale Model," Hydraulic Laboratory Report No. HYD-216, Bureau of Reclamation, Denver, CO, November 25, 1946 (unpublished). Bos, M.G., ed., Discharge Measurement Structures, International Institute for Land Reclamation and Improvement, Publication 20, third revised edition, Wageningen, The Netherlands, 1989. Buyalski, C.P., "Discharge Algorithms for Canal Radial Gates," Report REC-ERC-83-9, Bureau of Reclamation, Denver CO, December 1983. Christiansen, J.E., "Measuring Water for Irrigation," Bulletin 588, University of California, Berkley CA, 1935. Franke, P.G., and F. Valentin, "The Determination of Discharge Below Gates in Case of Variable Tailwater Conditions, Journal of Hydraulic Research, Vol. 7, No. 4, Delft, The Netherlands: International Association for Hydraulic Research, 1968. Henry, H., "Discussion Diffusion of Submerged Jets," Transactions of American Society of Civil Engineers, Discussion 115, 1950. Kruse, E.G., "The Constant-Head Orifice Farm Turnout," ARS 41-93, Agricultural Research Service, U.S. Department of Agriculture, January 1965. 9-18
Schuster, J.S. (ed.), "Water Measurement Procedures, Irrigation Operators' Workshop," Report No. REC-OCE-70-38, Bureau of Reclamation, Denver CO, September 1970.
9-19
Anemometer and propeller velocity meter Electromagnetic velocity meters Doppler velocity meters Optical strobe velocity meters
Most of these will be discussed briefly here. The class that is more commonly used for irrigation and watershed measurements is the anemometer and propeller type; however, the use of electromagnetic velocity meters is very popular among water districts. The discussion in the following sections will mainly describe this class and its use.
Where flow depths are too small for current meters and only small heads are possible, flumes are probably the best alternative measuring method. The discussion of current meters, gaging stations, and operational procedures presented in this chapter is brief and is intended mainly to stress the more typical irrigation water measurements that may be made by this method. For more detailed information, refer to USGS Water Supply Paper No. 888 (USGS, 1965), Buchanan and Somers (1969), the National Handbook of WaterData Acquisition (USGS, 1980), and Wahl et al. (1995).
Figure 10-1 -- Current-meter station on a canal, viewed from upstream. Current-meter measurements are taken from the bridge, and the sheltered stilling well houses an automatic water-stage recorder. A gaging station located upstream from any permanent single control section, such as a drop, will usually have a simple relationship between the gage height and discharge. A gaging station located in a river may have successively changing control points downstream as discharge increases or decreases, resulting in more complicated gage height versus discharge relationships. The last two types are not commonly used in irrigation practice and will not be discussed.
10-3
Wading measurement (figure 10-2). Cable supported measurement (figure 10-3). Bridge measurement (figure 10-4). Boat measurement (figure 10-5). Measurement through ice cover.
Figure 10-2 -- Equipment for making wading measurements with a current meter. Note tag line for marking stations.
Figure 10-3 -- Current-meter gaging station with cable car, corrugated steel shelter house, and stilling well.
For stream measurement, the crane is tilted to lean against the bridge rail so the boom supports the meter and weight clear of the bridge. The meter is raised and lowered by a crank and cable reel on the frame. The crane may be folded into a compact unit for ease in transportation. A cable device used extensively to position current meters across canals is shown on figure 10-6. The head tower with the operating mechanism for the cable and the tail tower on the opposite bank can be fixed installations, or vehicles may function as anchors on each side of the canal. A counter on the head tower reel determines the lateral position of the traveling block. Another counter on the reel raises and lowers the meter and determines meter depth. The entire installation is relatively inexpensive and permits stream gaging to be done safely and easily from the bank.
Figure 10-6 -- Cableway with traveling block to support the current meter and position it for readings. Counters are provided on the head tower and reel to determine the position of the meter in the channel. A carriage and track system to handle current meters with heavy weights when working from bridges is shown on figure 10-7. The standard reel and counter assembly is mounted on a carriage supported by ball-bearing rollers that run on a 2- by 6-inch (in) timber track permanently mounted on the bridge rail. This equipment allows the operator freedom of movement with safety, facilitates obtaining accurate stream gaging data, and is easily portable from one station to another.
Figure 10-7 -- Carriage and track for handling current meter and weights from a bridge. A 2- by 6-in timber permanently attached to the bridge rail is the track for the portable, wheeled carriage that supports the reel, cable, and meter assembly.
10-7
V = 2.14N + 0.03
and
(10-1)
V = 2.19N + 0.01
(10-2)
In these equations, V is the velocity in feet per second (ft/s), and N is the number of revolutions per second.
Figure 10-8 -- Typical current-meter rating table. Each meter is calibrated for the types of suspensions with which it may be used (Smoot, 1968). The two principal types of suspensions are wading rod and cables (shown on figures 10-2 and 10-4, respectively). Because accuracy is greatly affected by general condition, the instrument should be checked at least once a year. This check can be done by comparing the meter readings with a second meter by placing it in the same position in a non-changing flow. This procedure is done at low, middle, and high velocity to cover the meter measuring range. If significant difference exists between the two meter readings, or if another meter is not available for checking to begin with, then the meter should be sent to a laboratory for calibration.
This meter has the following general features: vanes to keep the front of the meter headed into the current, either a cable or a rod for handling the meter, weights for sinking the meter when it is suspended on a cable, an electric device for signaling and/or counting the number of revolutions, and connections from the current meter to a 12-volt battery-powered headphone (figure 10-9).
Figure 10-9 -- General assembly of Price type AA current meter (sheet 1 of 2).
Figure 10-9 -- General assembly of Price type AA current meter (sheet 2 of 2). The Bureau of Reclamation (Reclamation) commonly uses two standard Price-type meters: (1) the type AA meter with the Columbus-type weights or a wading rod, and (2) the type BTA meter (figures 10-10 through 10-13). The pygmy meter, discussed in the following subsection, is also a modification of the standard Price meter. The BTA meter has the same pivot, hub assembly, and shaft as the type AA meter, which eliminates the need for two sets of spare parts. The parts for type AA and BTA meters are interchangeable, except for the yoke and the contact chamber. Two sets of revolution-indicating contacts are provided in the type AA and BTA meters; one set indicates every five revolutions. The electrical cable should be connected to the counter most appropriate for the anticipated bucket wheel speeds. A type AA meter on a wading rod is shown on figure 10-13.
10-9
10-10
An improved contact chamber has been developed by USGS to replace the wiper contact of the Price type AA meter (USGS, 1965). The new chamber contains a magnetic switch that is hermetically sealed in a hydrogen atmosphere within a glass enclosure. The switch assembly attaches rigidly to the top of the meter head just above the tip of the shaft. The switch is operated by a small permanent magnet fastened to and in balance with the shaft. The switch quickly closes when aligned with the magnet and promptly opens when the magnet moves away. One count per revolution is obtained. The magnetic switch can be used on any type AA meter by replacing the shaft and the contact chamber. The change does not alter the rating of the meter. Headphones must not be used with the new switch because arcing can weld the switch contacts. Instead, an automatic counter should be used (USGS, 1965).
10-11
Figure 10-14a -- "Dumas" current meter of the propeller type with horizontal axle. Hott and Ott meters are of the same type.
Figure 10-14b -- Truck-mounted assembly of eight propellertype current meters and signal recording equipment used on Gateway Canal, Weber Basin Project, Utah.
8. Wading Rods
Two types of wading rods are available for supporting the current meters when working in shallow and moderate-depth streams: (1) the conventional round rod and (2) the more convenient top-setting rod. Both rods use a baseplate that rests on the bottom of the flow channel. The round rod (figure 10-13) consists of several sections of 1-ft-long, 2-in-diameter, nickelplated round brass tubing. The rod is graduated at intervals of 0.1 ft by shallow machined lines around the rod. A single groove is used at the 0.1-ft graduations, double grooves at the 2-ft intervals, and triple grooves at the foot marks. A nickel-plated sliding support machined from a bronze casting moves up or down on the rod and is held at any desired location by a springactuated lock which uses a lever for release. The current meter and the vanes, if used, attach to this sliding support. 10-12
The top-setting wading rod (figure 10-15) permits all settings to be made in the dry and has a main column of 2-in hexagonal stock and a meter positioning rod of d-in-diameter stock. The main rod attaches to the baseplate and is graduated in 0.1-ft intervals so depth of flow can be measured. Interval markings are the same as those used on common wading rods. The meter is secured to the lower end of the positioning rod and guided by means of a support that slides on the main rod. The position of the meter and sliding support is set by raising or lowering the positioning rod which extends through the handle at the top of the main rod. When the elevation of the meter is set to read the depth on the vernier, it will be at the 0.6 depth position. Doubling the vernier reading puts the meter at the 0.2 depth, and halving puts it at 0.8 depth. Once set, the positioning rod, and hence, the sliding support and meter, is secured by a locking device on the handle. Thus, all adjustments are made from above water so the operator's hands and the log can remain dry.
The meter should be spin tested before and after completing measurements to assure that the meter has no error-causing damage. With the shaft in a vertical position and the cups protected from air currents, the cups should be given a quick turn to start them spinning. If the meter is in proper adjustment and the bearings are free from foreign particles, the cups should come to rest in not less than 3 minutes. If the length of spin is only about 12 minutes, but the cup wheel comes to rest gradually, all flows except those of very low velocities may be measured. If the length of spin is only about 1 minute but the cup wheel comes to rest gradually, the meter may still be used to measure velocities above 1 ft/s. If the length of spin is less than 1 minute, the meter should be reconditioned. Under laboratory controlled conditions, rotation should continue for about 4 minutes. The manner in which rotation ceases will help indicate the condition of the meter and should be observed. The cross section of the stream should be divided vertically into 20 or more segments. Very small streams and sections with smooth, firm boundaries are exceptions, and a smaller number of stream cross-section segments would be sufficient. A single vertical reading is used if the distance between verticals is less than 1 ft. Horizontal divisions are generally selected so not more than 10 percent, and preferably not more than 5 percent, of the discharge will occur between any two adjacent verticals. The stopwatch should be checked frequently and kept in good condition. For low and irregular velocities, the period of observation should be lengthened to obtain a more accurate average count. The current meter should be withdrawn from the water between velocity readings to make sure that rotation is not being impeded by debris or any other cause. The meter should be allowed at least 10 to 20 seconds to attain rotation speed before counting commences. 10-14
The total operation of the meter at each elevation of a vertical should consist of at least two consecutive periods of at least 40 seconds. If significant differences are apparent in each period, more readings should be taken. Measurements while wading should be done facing the bank, standing just downstream from the tag line, and at least 18 in to the side of the meter.
Is placed closer to the boundary than 1-2 rotor diameters Is used to measure velocities less than 0.5 ft/s or out of the range of calibration. Overdriving the rotor can damage bearings Is not held steady in one position during the time measurement Is used in significant waves, such as those caused by wind Is used in flow which is not parallel to the axis of the propeller meter or is oblique to the plane of the cup-type meter Is impeded by weeds or debris
Two-point method Six-tenths-depth method Vertical velocity-curve method Subsurface method Depth integration method Two-tenths method Three-point method One-point continuous method
The two-point method consists of measuring the velocity at 0.2 and then at 0.8 of the depth from the water surface and using the average of the two measurements. High accuracy is obtainable with this method, and its use is recommended. However, the method should not be used where the depth is less than 2 ft. The six-tenths-depth method consists of measuring the velocity at 0.6 of the depth from the water surface and is generally used for shallow flows where the two-point method is not applicable. The method gives satisfactory results. 10-15
The vertical velocity-curve method consists of measuring the velocities at enough vertical positions so that the velocity profile is defined well enough to calculate a sufficiently accurate mean velocity. The method is very accurate, depending upon the number of data points measured for profile, but is time consuming and costly. The subsurface method involves measuring the velocity near the water surface and then multiplying it by a coefficient ranging from 0.85 to 0.95, depending on the depth of water, the velocity, and the nature of the stream or canal bed. The difficulty of determining the exact coefficient limits the usefulness and accuracy of this method. The depth or traveling integration method is performed by observing the velocity along a vertical line by slowly and uniformly lowering and raising the meter throughout the range of water depth two or more times. The method is not accurate and should be used only for comparisons or quick, rough checks. The two-tenths, three-point, and one-point continuous methods are special procedures based on a relationship - previously established for the section - between the true discharge and the velocities observed by these methods. These methods are generally reliable for sections which undergo no serious changes because of erosion, sedimentation, or other deformation. They are discussed in detail in USGS (1965) and USGS (1980). Of the methods cited in this section, the two-point method and the six-tenths-depth method are most used in canal work.
qn = n an
The total discharge is then:
(10-3)
Q=
(
1
an )
The simple average, the midsection method, and Simpson's parabolic rule applied to both the depth and average vertical line velocity values will be discussed using figure 10-16. This figure shows: (a) where the boundary is broken up into inflecting straight line sections and (b) where the boundary is smoothly curved.
10-16
q = the discharge in cubic feet per second (ft3/s) for a partial area Q = total discharge = the mean velocity associated with the partial area a = partial area of total cross section L1, L2,... Ln= distance to vertical measurement locations in feet from an initial point to vertical station L = the distance in feet between consecutive vertical measurement stations 1, 1,..... n = the respective mean velocities in feet per second at vertical measurement stations D1, D2,... Dn= the water depths in feet at verticals n = the number of verticals related to the partial area
q3-4 = [
3 + 4 D + D4 ][ 3 ] ( L4 L3 ) 2 2
(10-5)
The two hyphenated integers as a subscript denote that the partial discharge, q, is for the area between two consecutive vertical measurement points as numbered.
qn = n [
( Ln Ln 1 ) + ( Ln +1 Ln ) ] Dn 2
(10-6)
The value, n, with plus and minus after it denotes that the partial discharge, q, is for the area between halfway back toward the previous vertical measurement and halfway toward the next forward vertical. The mean velocities are determined by any one of the methods listed in section 12. For these two methods, the verticals do not need to be equally spaced, but the verticals should be chosen such that:
10-18
(1) The error of computing the area between the verticals does not exceed 3 percent when the bed is treated as straight lines between the verticals. (2) Except at the banks, the difference between the mean velocities at the verticals does not exceed 20 percent relative to the lower velocity of a pair of verticals.
An = (
Dn 1 + 4 Dn + Dn +1 ) L 3
(10-7)
where is the distance between consecutive vertical velocity measuring stations which are equally spaced across the flow section. Using Simpson's rule to obtain the mean velocity of three consecutive verticals or over two consecutive partial areas is expressed as: < n> = L (
n 1 + 4 n + n +1 )/2L 3
(10-8)
The product of this velocity and the area from the previous equation results in the relationship for the discharge through the two consecutive partial areas, written as:
qn = (L(
n 1 + 4 n + n +1 D + 4 Dn + Dn +1 )/2L) ( n 1 )L (10-9) 3 3
Typical discharge computations obtained by the midsection method, equation 10-5, are illustrated on figure 10-17. Velocities were taken from the current-meter rating table on figure 10-8.
10-19
Figure 10-17 -- Typical current-meter notes and computations for the midsection method using equation 10-5 (sheet 1 of 3).
10-20
Figure 10-17 -- Typical current-meter notes and computations for the midsection method using equation 10-5 (sheet 2 of 3).
'
10-21
Figure 10-17 -- Typical current-meter notes and computations for the midsection method using equation 10-5 (sheet 3 of 3). Simpson's parabolic rule method is particularly applicable to river channels and old canals that have cross sections conforming in a general way to the arc of a parabola or to a series of arcs of different parabolas. Simpson's method requires equally spaced verticals. The simple average and the midsection methods do not require equally spaced verticals. Thus, these two methods are well suited to computing discharges in canals that conform closely to their original trapezoidal rectangular shapes.
This change in flow capacity of the canal for a given depth of flow must be taken into consideration when computing the quantity of water carried by the canal. If the canal is cleaned during the season, the relationship of discharge to gage height is again disturbed. The changing relationship of discharge to gage height in irrigation canals caused by changing boundary conditions is the chief source of error in flow measurements.
Figure 10-18 -- Typical discharge, mean velocity, and area curves for a canal. The probable area curve is established first by drawing the most probable line through the data points. Using this curve, the accuracy of the area computations and of the flow depth measurements may be checked. Next, the computed mean cross-sectional velocities are plotted, and a curve is drawn through the points. This curve provides a check on the velocity computations and helps detect changes in velocity that may occur in the canal because of changing roughness or silting in the canal. Finally, the discharge curve is drawn through the computed discharge points. If flow conditions in the channel did not change resistance significantly during the period needed for measurements over the full range of canal flows, the curve will generally be easy to draw. 10-23
If the relationship of discharge to gage height was affected by growths or sediment deposits, one or more additional discharge curves must be drawn. The number of rating curves required for a cross-section location depends upon the degree of the flow restrictions encountered and the rate at which the restrictions developed. These curves will generally be parallel to, but slightly displaced from, the curve for the clean canal. For the periods when the change is in progress, discharges may be estimated by proportioning between curves for the clean and restricted conditions on a time basis.
10-24
23. Bibliography
Buchanan, T.J., and W.P. Somers, "Stage Measurement at Gaging Stations," chapter 10, book 1, Surface Water Techniques Series, U.S. Geological Survey, Washington DC, 1965. Buchanan, T.J., and W.P. Somers, "Discharge Measurements at Gaging Stations," U.S. Geological Survey Techniques Series, Water-Resources Investigation, Book 3, A8, 65 pp., 1969. Rohwer, C., The Use of Current Meters in Measuring Pipe Discharges, Technical Bulletin 29, Agricultural Experiment Station, Colorado State University, Fort Collins, CO, 1942. Smoot G.F., and C.E. Novak, "Calibration and Maintenance of Vertical-Axis Type Current Meters," U.S. Geological Survey Techniques, U.S. Department of the Interior, U.S. Geological Survey, 1968. U.S. Geological Survey, "Describing Methods and Practices of the Geological Survey, Discharge Measurements at Gaging Stations," Water Supply Paper No. 888, Book 1, Chapter 11, 1965. U.S. Geological Survey, Office of Water Data Coordination, National Handbook of Recommended Methods of Water-Data Acquisition. Prepared cooperatively by agencies of the U.S. Government, Government Printing Office, Washington DC, 1980. Wahl, K.L., W.O. Thomas, Jr., and R.M. Hirsch, "The Stream-Gaging Program of the U.S. Geological Survey," Circular 1123, U.S. Geological Survey, Washington DC, 1995.
10-25
Figure 11-1 -- Transit-time acoustic flowmeters. An acoustic flowmeter is a non-mechanical, non-intrusive device which is capable of measuring discharge in open channels or pipes. These flowmeters can provide continuous and reliable records of flow rates over a wide range of conditions including flow in both directions. Some typical applications include:
Acceptance testing of hydraulic machinery (turbines and pumps). Flow measurement in conduits of large (360 inch [in]) and small (1/2 in) diameter. Hydroelectric powerplant management. Volumetric metering. Wastewater or water treatment plants. Laboratory and field calibration of other flow measurement devices.
Two common methods are used to calculate discharge using acoustic flowmeters:
11-1
(c) Advantages
High accuracy, which can be achieved independent of velocity profile, flow rate, and liquid temperature. Bidirectional flow measurement capability. Non-intrusive, incurring no head loss. Field calibrations are generally not required. System cost is almost independent of pipe size. No moving parts and easily serviceable.
(d) Disadvantages
Relatively high initial cost. Requires electronic technician to troubleshoot and service. Must be programmed for each pipeline material, diameter, and wall thickness. Entrained gases and/or suspended sediment affect the acoustic signal strength.
11-2
2. Theory
Acoustic flowmeters were developed based on the principles that the transit time of an acoustic signal is longer in the upstream than downstream direction, and that these transit times can be accurately measured using microcomputer technology. Discharge measurements are based on determining the average axial velocity in a full-flowing pipe. Knowing this velocity and the cross-sectional area of the measurement section, a discharge can be calculated. The difference in transit times of acoustic signals traveling in opposite directions through the water can be related to velocity of flow (figure 11-1a). In the downstream direction, the velocity of the flowing water, Vw, adds to the speed of sound, C, to give the effective speed of the acoustic pulse, C + Vw. In the upstream direction, the velocity of flow delays the arrival of the pulse, resulting in an effective pulse speed of C - Vw. Taking the difference in these transit times eliminates C from the calculations and results in )t. When )t is known, the average axial velocity can be obtained from the formula:
Vaxial =
where:
(11-1)
Vaxial = average axial velocity of waterflow tu = upstream travel time of the acoustic signal td = downstream travel time of the acoustic signal t = difference in upstream and downstream travel times = angle between the acoustic path and the pipe's longitudinal axis L= acoustic path length between the transducer faces
Another acoustic flow measurement technique uses a similar approach which employs the frequency difference between upstream and downstream acoustic signals. This method is similar to the transit-time method and will not be covered. For more information, see American National Standards Institute/American Society of Mechanical Engineers (ANSI/ASME) standard MFC5M-1985.
3. Available Technology
At this time (1996), many different types of acoustic flowmeters are available. As mentioned in previous sections, transit-time and frequency difference devices, as well as devices which use chordal (multipath) or diametral (single-path) paths to measure the average velocity in the pipe are available. Some systems use clamp-on transducers mounted to the outside of the pipe wall, and some use internal or wet-mount transducers. Likewise, some transducers are mounted in a spool, and others are installed in an existing section of pipe. All these options have their advantages and disadvantages, and they will be covered later. All acoustic flowmeters consist of the following components.
11-3
(c) Transducers
The transducers transmit and receive the acoustic signals. They may be factory or field mounted by clamping, threading, or gluing them to the pipe wall. Transducers can be wetted by the fluid or can be attached to the outside of the pipe. Wetted transducers may be flush mounted, protruding, or recessed. Some wetted transducers can be replaced without taking the pipeline out of service.
4. System Errors
Error sources for acoustic flowmeters are primarily related to the measurement of the average axial velocity. The main source of errors occurs in the determination of the acoustic path length, L, and the path angle, . The error in the velocity measurement is directly proportional to the uncertainty of these two variables. Care must be taken to minimize errors in measuring path length and angles. This care is especially necessary for chordal path meters because the computational procedures require accurate positioning of the acoustic paths. Likewise, errors in the cross-sectional area of the measurement section cause an error in the discharge measurement. This error can be a result of out-of-roundness or shape irregularities caused by temperature, pressure, structural loading, or deposits on the pipe walls. In circular pipe, cross-section dimensional errors can be reduced by averaging diameter measurements made at upstream, midsection, and downstream ends of the measurement section. Another source of error occurs in measuring the transit times of the acoustic signals and in detecting the acoustic signal in the presence of electrical noise. 11-4
Signal detection can also be hindered by signal modifications caused by changes in acoustical properties of the liquid which are caused by entrained air, suspended solids, and changes in temperature and pressure. Likewise, transducer fouling by algae or mineral deposits can reduce signal strength. Secondary flows can create an error in the determination of Vaxial because the calculations are based on flow direction in the axial direction only. Secondary flow is caused by flow disturbances near the measurement section. These disturbances are typically caused by valves, elbows, or transitions. Secondary flow problems can be avoided by careful selection of the measurement section. For small pipes (diameters less than 36 in), 10 pipe diameters of straight pipe upstream and 3 to 5 diameters downstream from the measurement section should be sufficient. For pipe diameters greater than 36 in, 20 to 30 pipe diameters of straight pipe upstream and 3 to 5 diameters downstream may be required to obtain an acceptable velocity profile. If the measurement section must be placed near a bend, secondary flow errors can be reduced by orienting the acoustic paths perpendicular to the plane of the bend and locating the transducer as far downstream as possible. Likewise, another solution is the addition of another acoustic path which crosses the first path. Exact cancellations of secondary flow errors can be accomplished using a cross path configuration. The diametrically reflective path provides a cross path directly. Other variations in velocity profiles, due to Reynolds number effects and pipe wall roughness, can be corrected using a velocity profile correction factor. This correction factor corrects for the difference between the actual velocity profile and the profile assumed in the flowmeter's calculations. In general, deviations in velocity profiles are best accounted for by increasing the number of acoustic paths.
5. Installation Considerations
Many of the errors considered above can be eliminated or decreased by following the manufacturer's installation guidelines. Errors and their sources should be addressed prior to flowmeter installation. The following paragraphs cover areas which should be examined. More detailed descriptions are available in American Society for Testing and Materials (1984), American National Standards Institute (1985), and Laenen (1985).
11-5
(e) Calibration
In general, acoustic flowmeters do not require a field calibration when manufacturer's suggested installation criteria have been met or exceeded. However, in some cases, unusual installation conditions or the need for a high degree of accuracy may require a calibration. Three methods exist for flowmeter calibration: (1) laboratory calibration, (2) field calibration, and (3) analytical techniques. For more information on calibration techniques, a good reference is the ANSI/ASME standard MFC-5M-1985 (American National Standards Institute, 1985).
The potential for transducer fouling from various waterborne contaminants (algae, minerals, etc.) also exists. Theoretical equations used for acoustic flow measurement are based on the assumption that the transducers are in direct contact with the fluid. A protective covering or an external mount transducer will change the transit times and path angles. These changes are usually mathematically modeled by the manufacturer and corrected for by the secondary device.
Channel widths are large. Head loss must be minimized. High accuracy is required. Section rating and stream gaging costs are high. Bidirectional flow (tidal) must be measured. Continuous measurements over a long time period are required.
This section will cover any additional considerations associated with open channel acoustic flowmeters not covered in the previous section on closed conduit acoustic flowmeters. Laenen (1985) and Laenen and Curtis (1989) contain more detailed information on open channel acoustic flowmeters. Design of open channel meters is complicated by the potential errors introduced by a variable water surface and because the open channel environment can cause acoustic signal attenuation and refraction (bending). Another potential problem is signal deflection caused by density gradients or signal reflection from the channel bottom or water surface.
Therefore, care must be taken while measuring the discharge and in determining the channel's cross-sectional area for a range of stages. For installations where appreciable changes in stage occur, the transducers will have to be positioned to allow a full range of measurements.
(c) Limitations
Flowmeter accuracy and performance are limited by four factors: 1. Location of acoustic paths with respect to water surface and the channel bottom, which are reflective surfaces that can cause multipath interference at the receiving transducer(s). 2. Density gradients (usually caused by different water temperatures or salinities) cause the acoustic path to bend, which changes the acoustic path length. 3. Acoustic signal attenuation caused by varying concentrations of air bubbles, sediment, organic matter, and aquatic organisms. 4. Streamflow variability, which causes the angle between the acoustic path and the flow to change.
(d) Availability
Two types of equipment are available for use in measuring velocity: (1) a simple one- or twopath microprocessor based, preprogrammed system that will measure velocity only, and (2) a more complex, programmable, multipath minicomputer that can calculate discharge. At present (1997), open channel systems use 12 volts direct current or 110/220 volts alternating current.
If this condition cannot be met, an "effective" cross-section shape must be determined. The "effective" cross section is determined by taking the cross-sectional area along the acoustic path multiplied by the cosine of the path angle, . A concrete-lined section with a straight reach located upstream is ideal. During site selection, obtain cross-section survey information and note obstructions which may block the acoustic signal. Obtain temperature, total dissolved solids and sediment concentrations, and possible sources of air entrainment (overfalls, spillways, etc.). Variations in stage should be known in order to determine the number of acoustic paths required to assure the system accuracy.
(h) Calibration
Flowmeter calibration can be done using current meter measurements, other velocity-area methods, or using computations based on theoretical velocity profiles. The effort expended for calibration will depend upon factors such as number of acoustic paths, flow conditions at all stages, channel stability, and accuracy requirements. However, accuracy can be verified only within the limits of the calibration method used.
(i) Accuracy
For many streamflow conditions, a single-path flowmeter can measure flow within an accuracy of 3 to 5 percent. For multipath systems, accuracies of 2 percent or better can be achieved over a wide range of flow rates and channel conditions if the system design addresses the major sources of errors of acoustic flow measurement. Errors associated with open channel acoustic flowmeters are usually attributed to three sources: 11-9
1. Transit-time measurements, where timing errors can be on the order of 0.1 foot per second (ft/s) for systems which employ signal validation routines or 0.3 ft/s when signal validation techniques are not used. 2. Acoustic path angle variation. In general, for every one degree of uncertainty in path angle, about 1 percent uncertainty occurs in velocity measurement. Use of crossed acoustic paths will compensate for variations in streamflow direction. 3. Acoustic signal bending. For path lengths less than 1,000 ft, this error is usually less than 3 percent in velocity.
11-10
Web Resources The ADFM Velocity ProfilerTM - A Report on Laboratory and Field Demonstrations Conducted for the Bureau of Reclamation
Mike Metcalf - MGD Technologies Inc.; Tracy Vermeyen - Bureau of Reclamation, Water Resources Research Laboratory; Steve Melavic, John Fields - Bureau of Reclamation, Mid-Pacific RegionMike Metcalf - MGD Technologies Inc.; Tracy Vermeyen - Bureau of Reclamation, Water Resources Research Laboratory; Steve Melavic, John Fields - Bureau of Reclamation, Mid-Pacific Region
Introduction
A new type of flowmeter, the ADFM Velocity ProfilerTM (Profiler) was demonstrated on March 3 and 4, 1997 at the Bureau of Reclamation's Water Resources Research Laboratory in Denver, Colorado. The demonstration was organized by Tracy Vermeyen of the Bureau of Reclamation and Mike Metcalf of MGD Technologies, the manufacturer of the Profiler. A subsequent field test of the instrument was conducted in the San Luis Drain near Los Banos, CA, on March 14, 1997. John Fields and Steve Melavic of the Bureau of Reclamation's Mid-Pacific Regional Office were responsible for organizing this test. This report documents the results of these tests.
Figure 1. Cross section view of typical Profiler application. This figure shows the spatial relationship of the depth cells and the profiles relative to the transducer housing.
The Instrument
Figure 1 shows a typical Profiler installation for measuring open channel flow in a pipe. A transducer assembly is mounted on the invert of a pipe or channel. Piezoelectric ceramics emit short pulses along narrow acoustic beams pointing in different directions. Echoes of these pulses are backscattered from material suspended in the flow. As this material has motion relative to the transducer, the echoes are Doppler shifted in frequency. Measurement of this frequency shift enables the calculation of the flow speed. A fifth transducer is mounted in the center of the transducer assembly and is used to measure the depth. The Profiler divides the return signal into discrete regular intervals which correspond to different depths in the flow. Velocity is calculated from the frequency shift measured in each interval. The result is a profile, or linear distribution of velocities, along the direction of the beam. Each of the small black circles in Figure 1 represent an individual velocity measurement in a small volume known as a depth cell. The directions of the velocity profiles in Figure 1 are based on the geometry of the Profiler's transducer assembly. Figure 2 shows a side view of the transducer assembly. The profiles shown in Figure 1 are generated from velocity data measured by an upstream and downstream beam pair. The data from one beam pair are averaged to generate Profile No. 1, and a beam pair on the opposite side of the transducer assembly generates Profile No. 2.
Figure 2. Side view of the Profiler transducer assembly and its beam geometry.
Since Doppler measurements are directional, only the component of velocity along the direction of the transmit and receive signal is measured, as illustrated in Figure 2. Narrow acoustic beams are required to accurately determine the horizontal velocity from the measured component. The narrow acoustic beams of the Profiler insure that this measurement is accurate. Also, the rangegate times are short and the depth cells occupy a small volume - cylinders approximately 5 cm (2 in.) long and 5 centimeters in diameter. These small sample volumes insures that the velocity
measurements are truly representative of that portion of the flow and potential bias in the return energy spectrum due to range dependent variables is avoided. The result is a very precise measurement of the vertical and transverse distribution of flow velocities. The velocity data from the two profiles are entered into an algorithm to determine a mathematical description of the flow velocities throughout the entire cross-section of the flow. The algorithm fits the velocity data to the basis functions of a parametric model. The parametirc model is used to predict flow velocities at points throughout the flow. The resulting velocity distribution is integrated over the cross-sectional area to determine the discharge. The key benefit to this approach is that the system will operate accurately under variable hydraulic conditions. As hydraulic conditions change, the change will manifest itself in the distribution of velocity throughout the depth of flow. As the Profiler is measuring the velocity distribution directly, it can adapt to changes in the hydraulics, and generate a flow pattern that is representative of the new hydraulic conditions, insuring an accurate estimate of flow rate.
Test Procedure
The Profiler was first tested in two sites at the Bureau of Reclamation's Water Resources Research Laboratory in Denver: a 4-ft-wide flume, and a 12-ft-wide rectangular channel. In both lab sites, the system was installed on the bottom of the flume, centered with the transducer's long axis aligned with the flume's axis (flow direction). No in-situ calibration or rating was performed.
4 ft flume tests - The test began with a flow depth of approximately 4 ft. The depth was increased after about one hour to around 7 ft. Profiler flow measurements were then compared with the venturi meter flows to check for accuracy and repeatability. 12 ft channel tests - The test began with a depth of flow of approximately 2 ft. The depth was decreased after about one hour to about 1.2 ft. Profiler flow measurements were then compared with the venturi meter flows to check for accuracy and repeatability.
The venturi meter flows were determined using a mercury manometer to measured the pressure differential across the venturi. This manometer was manually read several times during the tests. Once set up, the flow was held constant as it was controlled by an active feedback control system. The laboratory venturi meter was calibrated prior to the Profiler demonstration. A weigh tank facility was used to calibrate the venturi meter and the uncertainty in the venturi meter measurement was within +0.8 percent of the weigh tank flow rate. Following the laboratory tests, the Profiler was placed in a "live" channel - the San Luis Drain located near Los Banos, CA. This channel is an irrigation drain for part of the San Joaquin Valley. The channel is trapezoidal in shape, with an 8 ft bottom width and 2:1 side slopes. The Profiler was placed on an aluminum strap about 44 ft in length. Hinges were placed on the strap so that the 8 ft. center piece would lay flat on the channel bottom and the rest of the strap would conform to the side slopes of the channel. The channel was in normal operation during the installation with a flow depth of approximately 7.2 ft.
11-14
Results
Figure 3 shows the results from the 4 ft flume tests. The round symbols represent the Profiler data and the square symbols are the spot readings from the venturi meter. As shown in figure 3, the Profiler data agrees very well with the venturi meter readings. At the beginning of the data record there is some scatter to the Profiler data, as the flow into the flume had just been set and the depth in the flume was still equilibrating. After the first few points, the flow rate readings and depth readings become steady. The Profiler measured an average flow rate of 6.86 ft3/s during the initial depth of flow of 4 ft (after depth equilibration), compared to 6.98 ft3/s for the venturi readings during the same time period; a difference of 1.72%. We also see a change in the Profiler flow rate measurement after the level was increased to 7 ft at around 10:00 a.m. The Profiler over predicts the flow because one pair of acoustic beams intersects the walls of the flume. Consequently, the average velocity is skewed higher because it is measured near the middle of the flume where velocities are larger than near the wall.
Figure 3. Profiler and venturi flow rates measured in the 4 ft flume are plotted as a function of time. The Profiler's depth reading is also plotted to illustrate the effect of fluctuating water surface level on the discharge measurement accuracy.
The spacing on the x-axis is irregular because several sampling schemes, in which parameters such as bin size and sampling interval, were varied. In most cases, changing these parameters did not affect the overall accuracy of the flow rate measurement. 11-15
Figure 4 shows the results from the 12 ft channel test. The round symbols are the Profiler data and the square symbols are the spot readings from the venturi meter. For this test, the Profiler data were averaged over a variety of time periods. Whereas Figure 3 is a plot of "raw" flow data, where each point corresponds to a individual measurement separated by an interval varying from one to five minutes. The first seven ADFM measurements were collected with an one minute averaging interval. The average of these seven measurements is 10.48 ft3/sec. The venturi meter reading was 10.26 ft3/sec, and this flow remained constant for the remainder of the test. The next five ADFM measurements were collected with an averaging interval of 5 minutes. The average of these five measurements is 10.29 ft3/sec. The next six ADFM measurements were collected with an averaging interval of 2 minutes. The average of these seven measurements is 10.43 ft3/sec. This test demonstrates how Profiler measurements becomes more precise as the number of measurements averaged together were increased. The ability to average hundreds of flow measurements over a short period results in a very precise flow measurement. This is illustrated by comparing the average of the all eighteen Profiler measurements with the two venturi meter readings. The Profiler average was +0.97% different from the venturi meter average. The last ADFM measurement was collected with an averaging interval of 2 minutes at a depth of 1.2 ft. The measured flow rate was 10.0 ft3/sec. This measurement was made with a 10:1 width to depth ratio. This demonstrates the Profiler's unique capability to measure flows in wide, shallow channels.
Figure 4. Profiler and venturi flow rates measured in the 12 ft channel are plotted as a function of time. The Profiler's depth reading is also plotted. Initially the Profiler's discharge measurements were variable, but with time the accuracy improved to within 1 percent of the venturi-measured discharge.
11-16
Figure 5 contains a plot of the flow rate, depth, and average velocity measured in the San Luis Drain near Los Banos, CA on March 14, 1997. All three measured parameters were steady over the test period. Variations in the flow rate correlate with variations in the average velocity, as the depth remains fairly constant. The average flow rate over the duration of the test was 91.1 ft3/s. Flow rates of approximately 80 and 86 ft3/s were measured using traditional stream gaging methods. Stream gaging velocities were measured with a Marsh-McBirney Flo-Mate, which is an electromagnetic velocity meter.
Figure 5. Flow rate, depth, and average velocity plotted as a function of time. The average flow rate measured in the San Luis Drain was 91.1 cfs with a standard deviation of 2.0 percent.
The first discharge measurement was obtained by manually measuring velocities at 0.2 and 0.8 of the depth measured from the water surface, at regular intervals across the channel. These velocities were used to compute an average velocity for a particular section of the channel. Multiplying this average velocity by the cross-sectional area of the individual section gives a flow rate for that section. The section flow rates are summed to determine the total flow rate for the channel. The second discharge measurement was obtained by making a single velocity measurement at a height above the bottom of 0.6 of full depth, at regular intervals across the channel. This value was used as the average velocity in that section to compute a flow rate for that section. Again, section flow rates are summed to determine the total flow rate in the channel. 11-17
Note: This velocity measurement should have been measured at 0.6 of the depth measured from the surface not the bottom. It should be mentioned that there was some concern over the accuracy of the manual velocity measurements. The relationship between the velocities measured at the various depths was not as expected. In particular, the velocity value measured at a height above the bottom of 0.8 of full depth, in some cases, was lower than anticipated.
Conclusions
For laboratory tests, the Profiler measured flow rate with an accuracy of approximately 1.7% in the 4 ft. flume and 1.0% in the 12 ft. channel. The Profiler was able to accurately measure flow rate even with a width to depth aspect ratio of 10:1. This test demonstrated that the Profiler does not require an in situ calibration or rating Profiler to make an accurate flow measurement. Accurate flow measurements were attained without any special consideration to the installation, aside from placing the Profiler in the middle of the flow and aligning it with the direction of flow. The Profiler was successfully installed in a "live" channel, without interrupting the flow. Flow rates measured were repeatable and within roughly 10% of a traditional stream gaging measurement. However, there was some concern that the stream gaging measurement might not be accurate, as some velocities appeared lower than anticipated. This would lower the flow rate estimate generated by the stream gaging method. This demonstration was useful in showing the ability of the ADFM Velocity Profiler to measure flow rates in a variety of conditions with a minimal amount of time required to install and setup the instrument. This new technology has the potential to provide flow measurement in areas where traditional discharge measurement devices are impractical. It also could be a valuable tool for calibrations of existing flow measurement structures and for research studies that require velocity profile measurements. This instrument can accurately measure detailed velocity profiles in an open channel which can be used for engineering studies. For example, the ADFM can be used to measure velocity profiles which describe flow into and around structures such as fish screens or fish ladders.
Related links
MGD Technologies Inc. is a professional firm specializing in the assessment of the condition and performance of underground utility systems. The services are provided by highly trained individuals, experienced in the innovative application of integrated, advanced technologies. MGD's ADFM measures the flow velocity at discrete points throughout the depth of flow. MGD Technologies Inc. 9815 Carroll Canyon Road, Suite 200 San Diego CA 92131 USA Tel. 619 695 9225 Fax 619 695 6890
11-18
10. Bibliography
American Society for Testing and Materials, Open Channel Flow Measurement by Acoustic Means, Standard Practice D 4408-84, 1916 Race Street, Philadelphia PA 19103, 1984. American National Standards Institute, Measurement of Liquid Flow in Closed Conduits Using Transit-Time Ultrasonic Flowmeters, ANSI/ASME MFC-5M-1985, ASME United Engineering Center, 345 East 47th Street New York NY 10017, 1985. Laenen, Antonius, Acoustic Velocity Meter Systems, U.S. Geological Survey Techniques of Water Resources Investigations, book 3, chapter A17, U.S. Geological Survey, 1985. Laenen, A., and R.E. Curtis, Jr., Accuracy of Acoustic Velocity Metering Systems for Measurement of Low Velocity in Open Channels, U.S. Geological Survey, Water Resources Investigations Report 89-4090, 1989.
11-19
Dyes of various colors Other chemicals such as fertilizer, salt, and gases Radioisotopes Heat Traveling turbulent eddy pressure sequences Neutrally buoyant beads Floats
For irrigation measurements, salts and dyes are the most convenient and commonly used tracers. Salt tracers are sensed and quantified by measuring evaporated dry weight, chemical titration, or by measuring electrical conductivity. Dye concentrations are measured by fluorimetry or color comparison standards. Sometimes, visual observation of an exiting dye cloud is used, but considerable loss of accuracy occurs. Fluorescein, Rhodamine B, Rhodamine WT, or Pontacyl Pink B dyes have been used because they are easily visible in very dilute solutions. Rhodamine B and Rhodamine WT have been cleared as nontoxic by the U.S. Food and Drug Administration. Rhodamine and Pontacyl Pink B are also quite stable with respect to fading by sunlight and to changes caused by waterborne chemicals. They do not tend to deposit on flow surfaces, sediments, or weeds. These dyes are usually available in powder form, and solutions are easily prepared. Before conducting a discharge measurement program, selected dyes should be tested with water samples or earth canal embankment material samples and exposed to check for possible adsorption, chemical reaction, and fading effects on dye stability. 12-1
Less frequently used methods involve measuring temperature upstream and downstream from a heat source and electronic cross correlations of trains of turbulent pulsations using acoustic methods discussed in chapter 11. The use of surface floats is discussed in chapter 13. Neutrally buoyant beads are usually used in laboratory work to track flow. Mixtures of beads with different specific gravities can also detect and measure fluid density profiles and stratification. Radioisotopes are now rarely used because of their safety and pollution risks. In addition, isotope handlers must be licensed. However, use of any chemical or anything that can affect ecological characteristics of the water or conveyance boundaries may require clearance from several Federal and State authorities such as the U.S. Food and Drug Administration, the U.S. Environmental Protection Agency, and State fish and wildlife and natural resource departments. Government regulations and limits change with time and should be checked prior to a measurement program. However, even when operating within government regulations, public complaints related to taste and color and particles in the resulting water may occur.
Q=
AL T
(12-1)
Q = discharge in cubic feet per second (ft3/s) A = average cross-sectional area of reach length in square feet (ft2) L = reach length between detection stations in feet (ft) T = recorded time required for the tracer solution to travel between the detection stations at each end of the measurement reach in seconds (s)
12-2
QC0+qC1= (Q+q)(C2)
Solving for discharge in equation 12-2a results in:
(12-2a)
Q=q
where:
C1 C 2 C2 C0
(12-2b)
C0 = the natural or background concentration of the tracer of the flow C1 = the concentration of the strong injected tracer solution C2 = the concentration of tracer after full mixing at the sampling station, including the background concentration of the stream Q = the discharge being measured q = the discharge of the strong solution injected into the flow
Equation 12-2 can be modified for use in terms of weight by substituting percent of dry weight of tracer for concentrations and weight of water per second for discharges. The discharge of the channel flow, Q, is measured by determining C0, C1, C2, and the injection rate, q. These required variables and equation 12-2 show that the dilution method does not need measurement of channel geometry or time measurement. Only the final plateau value or C2, the downstream concentration, must be recorded rather than a complete record of the passing cloud that is needed with the salt-velocity-area method.
With elaborate equipment such as multi-port pop valves, turbulators (turbulence-creating devices), complex electrodes, and fluorometers, accuracy can approach +/-1 percent. This degree of accuracy requires using the procedures included in American Society of Mechanical Engineers Performance Test Codes (1992). For irrigation water, the strict code procedures, quality of procedures, equipment, and instrumentation can be relaxed to produce lower levels of accuracy. The selected accuracy target governs the complexity of needed injection equipment, detection equipment, and the quality of recorded data analysis. The least accurate method would involve breaking a bottle of dye contained in wire mesh at an upstream station of a long reach at time zero and visually observing and estimating the time that the center of mass of the dye cloud passes the exit. Any simplified procedure must be evaluated for effect on mixing. Prior to a measurement program, equations 12-1 and 12-2 should be used for error analyses in terms of proposed equipment and procedures because they affect the equation variables. These analyses will determine if the simplified measurement procedures produce the selected accuracy target.
6. Tracer-Velocity-Area Methods
Either salt or dye may be conveniently used in tracer-velocity-area discharge measurements with equal potential accuracy. The only difference is that different detection equipment is needed. Dyes have an added advantage in that they can be detected visually, allowing simpler measurements of less accuracy that may be sufficient for irrigation needs. However, when using any simpler method, the error checks and mixing problems of section 5 in chapter 12 should be considered.
12-4
Figure 12-2 -- Brine injection equipment in conduit. Commonly, sodium chloride (NaCl) is the selected salt used in the tracer injection solution. Finely ground salt should be purchased for ease in mixing the solution. Enough salt must be added to significantly increase the electrical conductivity of the water so that concentrations can be measured accurately. The required amount of salt can be estimated by analyzing the water for existing background quantity of salt in the measurement flow, estimating the amount of flow to be measured, and using chemical handbook data from conductivity-salinity tables. Trial runs may be needed to determine the optimum amounts, which may vary with discharge depending on the range to be measured. For a measurement, a quantity of salt tracer solution is forced into the stream under pressure to provide better initial distribution and assure thorough mixing before arrival at the detection stations. The pop valve injector used by Thomas and Dexter (1955) (figure 12-2) will provide the faster and better mixing required to produce code accuracy. To determine velocity for equation 12-1, a pair of electrodes is installed in the cross section at each end of a measured length of channel well downstream from the injection system. The distance between the pairs of electrodes should be sufficient to ensure accurate measurement of the time of travel between them. The electrodes are electrically energized and connected to a central instrument that records the electrical conductivity at each pair of electrodes with respect to time. A sample of a strip chart recording showing conductivity change that occurs as a salt cloud passes the electrodes is shown on figure 12-3. The recording shows a conductivity rise that indicates the passing of the salt solution cloud past each electrode station. 12-5
In addition to their peaks, the cloud plots have a leading and a trailing edge of low conductivity approaching the baseline conductivity of the flowing water (figure 12-3). The time of cloud travel between electrodes is measured on the chart time scale between the centroids of the two plotted conductivity cloud areas above the background conductivity level. Digital recordings are more convenient than analog recordings for computer determination of area under the timeconductivity plots to determine the center of mass of salt clouds.
Figure 12-3 -- Sample records of a salt cloud passing upstream and downstream electrodes in the salt-velocity method of measuring flows in pipelines. This method requires special equipment and experienced personnel and is relatively expensive. Care in selecting convenient reaches will help reduce time and expense in measuring length and determining an accurate average cross-sectional area.
12-6
Simplification similar to the pipe flow case is possible in open channel flow. However, the colorvelocity-area method in open channels has more limitations and drawbacks. The air entrained by surface velocities and spray above the surface may hinder detection of the position of the center of mass of the colored water in high-velocity flows (Hall, 1943). Also, slow flows are more likely to cause mixing problems.
7. Tracer-Dilution Methods
The tracer-dilution method is capable of measuring both open channel and closed conduit flow. However, possible tracer losses may be more of a problem in open channel flow as discussed previously. Either salts or dyes may be used as tracers. The tracer-dilution method consists of adding a known, strong concentration of tracer solution, C1 (equation 12-2) at a constant rate, to the flow (Schuster, 1970; Collins and Wright, 1964; and University of Newcastle on Tyne, 1964). Then, by chemical analysis, the downstream diluted uniformly mixed concentration, C2, is measured. The solution must be added at a known constant discharge, q. No measurements of flow section geometry or reach distance are required because the total flow is measured directly. The discharge of the channel flow, Q, is measured by determining C0, C1, C2, and the injection rate, q. These required variables and equation 12-2 show that the dilution method does not need measurement of channel geometry or time measurement. Only the final plateau value or C2, the downstream concentration, must be recorded rather than a complete record of the passing cloud that is needed with the salt-velocity-area method. Because the concentrated tracer solution must be added to the flow at a constant known rate, positive displacement metering pumps are needed for injection. Also, this method requires a sufficient flow travel length with enough turbulence to thoroughly mix the dye. Required mixing lengths can perhaps be reduced by turbulators or injecting the dye simultaneously at a number of points across the stream, but the injection arrays may need prevalidation by analysis and preliminary measurement runs to assure complete mixing. If salt solutions are used as tracers, then chemical or conductivity measurement methods are used for detection and concentration measurements. Finely ground salt should be purchased for ease in mixing the solution if selected as the tracer. If dyes are used, then visual color intensity comparison standards may be used. Modern fluorometers can measure dye amounts to one part of dye in a million parts of water and can detect one part in a billion. The human eye cannot detect these minute dilutions, but the dye is quite discernible to the instrument. The color-dilution method may be used for measuring small, medium, or large flows because the cost of the dye is relatively low. The salt-dilution method is applicable to measuring discharges in turbulent streams of moderate or small size where other methods are impracticable. Excessive quantities of salt are required on large streams. Tracer methods require special equipment and experienced personnel, and its use is relatively expensive. The injection equipment and electrodes or fluorometers for detecting and measuring the tracer concentration of the resulting downstream diluted flow make this method quite costly compared to other measuring methods.
12-7
8. Bibliography
American Society of Mechanical Engineers, "Performance Test Codes-Hydraulic Turbines and Turbine Mode of Pumps/Turbines," revision, Performance Test Code Committee, No. 18, New York, NY, 1992. British Standards Institution, "Method of Measurement of Liquid Flow in Open Channels," British Standards 3680, Part 3, 1964. Collins, M.R., and R.R. Wright, "Application of Fluorescent Tracing Techniques to Hydrologic Studies," Journal of the American Water Works Association, June 1964. Hall, L. Standish, "Open Channel Flow at High Velocities," Transactions, Paper No. 2205, vol. 108, American Society of Civil Engineers, p. 1394, 1943. Schuster, J.S. (ed.), "Water Measurement Procedures-Irrigation Operators' Workshop," Report No. REC-OCE-70-38, Bureau of Reclamation, Denver CO, September 1970. Thomas, C.W., and R.B. Dexter, "Modern Equipment for Application of Salt Velocity Method of Discharge," Proceedings of the Sixth General Meeting, vol. 2, International Association of Hydraulic Research, the Hague, Netherlands, 1955. University of Newcastle on Tyne, Dilution Techniques for Flow Measurement, Bulletin No. 31, February 1964.
12-8
3. Deflection Meters
These meters are out of production for irrigation use. However, some are still in use. These meters have some advantages, and they may come back into production. Deflection meters consist of a shaped vane(s) that projects into the flowing water to sense velocity. A secondary device measures the deflection caused by the force of the flow. These meters can be installed permanently or may be easily moved from one location to another. In use, they hang into the flow and are supported on pivots. 13-1
Vanes can be shaped to match the flow section geometry to make them deflect the same amount for any given discharge regardless of the depth of flow in the flow section. This attribute is a considerable advantage where the head-discharge characteristic of the channel is unstable. Flow sections with permanent pivots can be installed at various locations in an irrigation district, and the vanes can be transported from measuring station to measuring station. Under ideal conditions, deflection meters have been found to be accurate within 2 percent. Generally, this accuracy will not be attained because field conditions are seldom ideal. For example, wind can produce errors up to 100 percent. However, a windbreak made from a piece of plywood will substantially reduce this kind of error.
6. Slope-Area Method
The slope-area method consists of using the slope of the water surface in a uniform reach of channel and the average cross-sectional area of that reach to give a rate of discharge. The discharge may be computed from the Manning formula: 13-2
Q=
where:
Q = discharge (ft3/s) A = mean area of the channel cross section (ft2) Rh = mean hydraulic radius of the channel (ft) S = energy slope of the flow n = a roughness factor depending on the character of the channel lining
A straight reach of the channel should be chosen at least 200 ft and preferably 1,000 ft in length. If the reach is free of rapids, abrupt falls, or sudden contractions or expansions, then the water surface slope is the same as the energy slope. The slope, S, may be determined by dividing the difference in the water surface elevations at the two ends of the reach by the length of the reach. A gage point, carefully referenced to a common datum level, should be placed on each bank of the channel and in the center of the reach, in stilling wells if possible. The hydraulic radius, Rh, is defined as the area of the cross section divided by its wetted perimeter. Where the channel or canal is of regular cross section, and the depths at the ends of the course are equal, the area and the wetted perimeter will be constant through-out the course. In irregular channels, the area and the wetted perimeter at several cross sections will be required, and a mean value will be used in computing the hydraulic radius. A static pressure tube, discussed in chapter 8, can be used to measure depth of flow. The factor, n, depends on the character of the channel. It may vary from 0.010, where conditions approaching the ideal are maintained, to 0.060, where the channel is strewn with stones and debris or is about one-third full of vegetation. Because the proper selection of the roughness factor, n, for many streams is difficult and is, at best, an estimate, the discharge determined by the slope-area method is only approximate. Care must be taken to determine the slope and areas simultaneously if the water levels are changing. Chapter 2 provides other flow equations, their friction factors that can be used with this method, and references with tables of friction factors.
Thus, pitot tubes have the problem of precision of head measurement relative to the size of head differential. Depending on needed accuracy, the secondary equipment could be costly and difficult to use in slow velocity. Pitot tubes and their use are more fully described in chapter 14.
9. Weir Sticks
Weir sticks are commercially calibrated stick or staff gage type devices which may be placed by hand upon the crest of a weir. In principle, the sticks show depth of flow plus velocity head or the runup of water above the water surface at the weir blade. This device gives an indication of the head that would have been measured at conventional weir measurement stations. Readings are taken at the top of the runup of water to indicate the rate of flow. Some sticks contain a piezometer and manometer to average the pulsations in the head reading. Turning the stick to an angle will not improve accuracy unless the stick has been calibrated in this position. At best, the sticks can only approximate the potential accuracy of weirs when head is carefully measured in the normal manner. Weir sticks are designed to measure unit discharge along the crest of rectangular suppressed weirs. Thus, the gage indicates the discharge per unit length of weir. The design intent was to make weir measurements simpler without need for staff gage zero setting. Also, poor distribution of velocity of approach at the crest could be accounted for by multiple stick measurements and averaging along the crest because the weir stick measures the depth on the crest and the corresponding velocity head. Thus, they compensate for velocity of approach, such as caused by sediment deposits ahead of the weir blade.
Surface velocity measurements should only be attempted on windless days to avoid wind-caused deflection of the floats. Even under the best conditions, surface floats are often diverted from a direct course between measuring stations because of surface disturbances and crosscurrents. Surface floats are immersed one-fourth or less of the flow depth. Rod floats are submerged more than one-fourth of the depth but do not touch the bottom. Cross sections are established along the straight reach of the channel at a beginning, midpoint, and end. The cross sections should be located far enough apart so the time interval required for the float to travel from one cross section to another can be accurately measured. The midpoint cross section provides a check on the velocity measurements made between the beginning and end sections. The channel width across the sections should be divided into at least three, and preferably at least five, segments of equal width. The average depth of each segment must then be determined. The float must be released far enough upstream from the first cross section to attain stream velocity before reaching the cross section. The times at which the float passes each section should be observed by stopwatch and recorded. The procedure is repeated with floats in each of the segments across the canal, and several measurements should be made in each segment. For flows in canals and reasonably smooth streams, the measured surface float velocities should be multiplied by the coefficients as listed below: Table 13-1. Coefficients to correct surface float velocities to mean channel velocities Average depth in reach (ft) 1 2 3 4 5 6 9 12 15 >20 Coefficient 0.66 0.68 0.70 0.72 0.74 0.76 0.77 0.78 0.79 0.80
The corrected velocities should then be multiplied by the cross-sectional area of the corresponding stream segments to obtain the segment discharges. The sum of the segment discharges will be the total discharge. A method used extensively in India to determine velocities in open channels makes use of rod or tube floats. This device consists of a square or round wooden rod with a width or diameter of 1 to 2 in, depending on the length. The rod is designed with a weighted end so it will float in a vertical position with the length of the immersed portion about 0.9 times the depth of the water. This method is based on the reasonable assumption that the velocity of a rod float extending from the water surface to very near the bottom of a channel will closely represent the mean velocity of the water. Streams are divided into segments as described for the float method, except that velocities in areas near the banks of the channel are not measured by the rod method but are assumed to be two-thirds or three-quarters of the mean velocity of adjacent segments. 13-5
The rod float method may be used in canals with straight stretches that are regular and uniform in cross section and grade. Where these conditions exist and the flow is free of cross currents and eddies, discharge measurements may be made with a high degree of accuracy. The accuracy of float methods are limited by many factors, including a lack of preciseness in the coefficients, too few stream segments being used, appreciable changes in stream depth along the test reach, oblique currents, wind forces, and experimental errors in measuring time and distances. Often, a number of people are required to perform this technique and make observations. The course of the floats is difficult to control, and they can be easily retarded by dragging on submerged debris and on the sides and bottom of the channel.
Differential head meters Positive volume displacement summing meters (generally municipal water) Calibrated velocity sensing meters Measured proportional or calibrated bypass meters Acoustic-type meters
Flowmeters can display or record total volume delivered or instantaneous discharge rates. Direct reading of totalized volume, rather than computing volume from instantaneous discharge readings, is especially convenient where water is sold on the volume basis. Many flowmeters are also equipped with auxiliary equipment to record and display the instantaneous flow discharge. This feature is of great advantage for irrigation when setting rates and controlling delivery. Water measured in closed conduits with mechanical meters must be free of foreign matter. Meters should be inspected regularly (see chapter 5) to detect wear, corrosion, or other change that would tend to alter accuracy. Flowmeter use is limited by relatively high cost and short life in adverse operating environments.
The basic energy balance relationship is written as discussed in chapter 2. The velocity at one of these locations is solved for in terms of the difference of head between the two locations. Using the product of the upstream velocity and area results in discharge expressed as:
Qa = CA1A2
where:
2 g (h1 h2 )
A1 A2
(14-1)
Qa = discharge A1 = upstream approach area A2 = area of the throat or orifice opening h1 = upstream head measurement h2 = downstream head g = gravity constant C = coefficient determined experimentally
The term, h1 - h2, often written in shorter form as h, is the differential head that gives the name to this class of meters. The values of the effective discharge coefficient in both of the equation forms, for the same differential flowmeter, are the same. The coefficients are the same because the area divided by the square root of the denominator in each equation has the same value. Equation 14-1 is valid for the venturi, nozzle, and orifice meters using proper respective effective coefficients. Each kind of flow meter has a different value of effective discharge coefficient. More details concerning what is accounted for by the effective discharge coefficient are covered in chapter 2. With differential flowmeters, the pressure difference between the inlet tap and the throat or minimum pressure tap is related to discharge in tables or curves using the suitable coefficients with the proper equation. An example discharge curve is shown for an 8-inch (in) venturi meter on figure 14-1. Thus, the meters may serve as reliable flow measuring devices.
Figure 14-1 -- Typical calibration curve for an 8-in venturi meter - one kind of differential flowmeter.
14-2
Figure 14-2 -- Sectional view of venturi meter. The American Society of Mechanical Engineers (1983) and International Organization for Standardization (1991) contain details of pipeline meter theory, equations, coefficients, and tables with application instructions. The effective discharge coefficient for venturi meters ranges from 0.9 to about unity (Streeter, 1951; American Society of Mechanical Engineers, 1983) with turbulent flow, and it varies with diameter ratio of throat to pipe. The smaller commercial venturi meters are made of brass or bronze and are available for pipe sizes up to about 2 inches (in) diameter. Larger meters are usually made of cast iron with inner bronze linings. Some larger venturi meters have been constructed of concrete with the convergence and the throat made of finished metal. Large venturi meters have not been standardized for general irrigation practice, and the sizes, shapes, and coefficients are not well known. Accuracy and performance should be specified by purchase contract for large venturi meters. Some relatively simple and effective venturi meters have been made from precast concrete (Summers, 1952; 1953) and plastic (Replogle and Wahlin, 1994) pipe sections and fittings. In the past, the expense of venturi meters and the fact that they must always operate with full pipelines have restricted their use on a broad scale in irrigation systems. The increasing demand for accurate flow measurements in pressure conduits will likely result in greater use of venturi meters in the future. Because venturi meters have smoothly varying flow boundaries, they have been used for measuring sewage and flow carrying other materials. Sometimes, this usage may require clean water backflushing for clearing manometer tubing. With trash-carrying flow that would require frequent flushing, small continuous purging flows have been used to keep material from plugging or entering the pressure taps between and during pressure head measurements. Many variations of the meter exist, each of which is tailored to meet the requirements of specific types of installations.
14-3
Figure 14-3 -- Sectional view of nozzle meter. The effective coefficient of discharge for flow nozzles in pipelines varies from 0.96 to 1.2 for turbulent flow and increases as the throat-to-pipe-diameter ratio increases. Frequently, the upstream pressure connection is made through a hole in the wall of the conduit at a distance of about one pipe diameter upstream from the starting point of the flare of the nozzle (ASME, 1983). Thus, the pressure is measured before it curves to enter the nozzle. The downstream pressure connection may be made through the pipe wall just above the end of the nozzle tube (ASME, 1983). Flow nozzles have been made from precast concrete pipe and used in the field. Flow nozzles have not been used extensively for measuring irrigation water, probably because this application lacks standardization. Discharge tables provided by a manufacturer agreed closely with independent calibration tests and studies (Summers, 1952).
14-4
Figure 14-4 -- Sectional view of orifice meter. Applications with proper water quality, careful attention to installation detail, and proper operation techniques (Hobbs, 1987) make these flowmeters capable of producing accuracy to within 1 percent. However, the usual maintenance and pipe conditions that generally occur in irrigation pipe systems limit field accuracies to within 3 to 5 percent of actual. Advantages of the orifice plate are its simplicity and the ability to select a proper calibration on the basis of the measurements of the geometry (Dijstelbergen, 1982). Disadvantages of the orifice plate include the long, straight pipe length requirements and the limited practical discharge range ratio of about one to three for a single orifice hole size. However, the location of the range can be shifted by using sets of plates for changing orifice hole sizes. This shift, in effect, provides a range ratio increase. Calibrations based on tap locations relative to pipe diameter, rather than orifice diameter, make this feasible because the same tap locations can be used for different orifice plate hole sizes.
Q = CCv A 2 gh Q = Cd A
where:
2 gh
(14-2a) (14-2b)
Q = the discharge Cd = the product CCv C = a coefficient determined experimentally Cv = the velocity of approach factor A = the area of the orifice hole g = the acceleration of gravity h = the differential head
If differential pressure sensing equipment is used as the secondary measuring devices, then 2gh must be replaced with 2P/D, where P is differential pressure and D is the density of the flowing water.
14-5
Figure 14-5 -- Flange and D-D/2 pressure taps for orifice meter.
Cd = coefficient of discharge L1 = the tap distance from the upstream face of the plate L2 = the tap distance from the downstream face of the of the orifice plate D = the pipeline diameter = the ratio of orifice diameter to pipe diameter Re = the Reynolds number (VD/v) V = the pipeline velocity v = the kinematic viscosity of the water
The minimum allowable Reynolds number varies with diameter, tapping arrangement, and . The Reynolds number (VD/v) for flange and (D-D/2) taps must be greater than 1,260 2D. For corner taps Reynolds number must be greater than 10,000 for greater than 0.45. For less than 0.45, the Reynolds number must be greater than 5,000. 14-7
The first three terms of equation 14-3 give the corner tap coefficient when Reynolds number (Re) effect is insignificant. The fourth term introduces Reynolds number effect. The last term accounts for the distance of flange and D-D/2 taps from the upstream face of the orifice plate. Although the equation appears to give a coefficient value for all tapping locations, standardized or not, it was not developed with data for other than standard locations and, therefore, is not recommended for nonstandard tapping locations. The coefficients by this equation are substantially the same as found in older presentations. Differences come mainly from the data fitting method. Uncertainty of the coefficient is claimed to be less than 1 percent, exceeding the usual requirements for irrigation use. The equation which relates flow rate to head differential and other parameters may seem to be rather complicated but is a minor inconvenience with modern computer capabilities. For the usual irrigation practice that accepts meter accuracies within 3 percent or more, the above precautions can be relaxed considerably.
4. Propeller Meters
Propeller meters are commercial flow measuring devices used at the ends of pipes and in conduits flowing full and under pressure (figure 14-6). The uses of propeller meters at the end of pipes (open flow propeller meters) are discussed in chapter 13. Propeller meters use multiple blades made of rubber, plastic, or metal. The propeller rotates on a horizontal axle geared to a totalizer that displays total volume that has passed the meter. The propellers are sometimes hung from a sealing plate with a gasket to seal around a saddle opening on the top of the pipeline. Others have propellers supported by spiders in short, permanent tubes for connection into pipeline flow. Some meters also display instantaneous discharge rate with indicator hands on dials.
Figure 14-6 -- Typical propeller meter installation. The meters are available for a range of pipe diameters from 2 to 72 in. They are normally designed for water flow velocities up to 17 feet per second (ft/s). The accuracy of most propeller meters varies from +/-2 to +/-5 percent of the actual flow. Greater accuracy is possible, and minimum driving velocities as low as 0.5 ft/s are sometimes claimed for certain meters. These claims may, at times, be justified; however, they are sometimes difficult to verify or reproduce, even in carefully controlled laboratory tests. Small changes of frictional resistance of bearings and other mechanical parts caused by wear can cause large deviations from calibration, especially at the low discharge end of measurement range. 14-8
With wear, error increases greatly for velocities below 1 to 1.5 ft/s. Propeller meters should be selected to operate near the middle of their design discharge range. This equipment can be a problem in existing irrigation systems with oversized pipes relative to delivery needs. Sections of the oversized pipe may need to be replaced with smaller pipes to provide enough velocity and approach pipeline length to allow development of velocity profiles. Any condition that makes the approach flow different from calibration conditions affects the accuracy of the meter registration. Insufficient driving velocity relative to friction, unusual velocity distributions, or undeveloped velocity profiles and spiral flow can cause considerable errors. If the propeller diameter measures less than half of the pipe diameter, the meter will be more sensitive to velocity profile differences. Changes in velocity distribution or velocity profile also influence registration. If the conduit from the canal to the meter is less than about six diameters long, typically, flow does not have sufficient time to develop a normal velocity distribution profile. This condition results in a blunt, evenly distributed velocity pattern (figure 14-7, case A). However, a conduit length of 20 to 30 diameters or longer will allow a typical, fully developed velocity profile (figure 14-7, case B).
Figure 14-7 -- Velocity distributions in a pipeline. With a fully developed velocity profile (case B), the velocity of flow near the center of the pipe is high, compared to the velocity near the walls. Thus, a meter with a propeller diameter of only half that of the pipe diameter would read 3 to 4 percent higher in this flow distribution than it would in the flat velocity profile (case A). Larger propellers up to 0.8 of the pipe diameter sample more of the flow velocity, producing greater potential accuracy. Laboratory tests show this statement to be true; and when the propeller diameter is 75 percent or more of the pipe diameter, the variation in registration caused by these velocity profile changes are minor. Spiral flow is caused by poor entrance conditions and combinations of bends and fittings such as valves. Measurement errors caused by spiral flow can be large and, depending on spiral rotational direction of the flow, are either positive or negative. Normally, the manufacturer provides detailed installation instructions which should be followed carefully. The same straight pipe approach and flow straightening vanes to prevent spiral flow that the manufacturer uses during calibration must be reproduced in field installations. Straightening vanes, at least several pipe diameters long, should be placed in the straight pipeline an appreciable distance upstream from the meter as specified by the manufacturer.
14-9
Propeller shafts are usually designed to rotate in one or more bearings. Bearings are contained in a hub, where they are protected from direct contact with objects in the flow. However, water often can and does enter the bearing. Some hubs trap sediment or other foreign particles. After these particles work into the bearing, a definite added resistance to turning becomes apparent. Some propellers are, therefore, designed for flow-through cleaning action so that particles do not permanently lodge and partially consolidate in the bearings. However, some of these bearing flushing systems have been plugged when the bearings have become fully packed with sediment. Newer propeller meters generally have sealed or ceramic bearings to minimize sediment wear problems. Although propellers are designed to pass (to some degree) weeds, moss, and other debris, only a limited amount of foreign material that can be tolerated in the flow. Even moderate amounts of floating moss or weeds can foul a propeller unless it is protected by screens. With larger amounts or certain kinds of foreign material in the water, even screens may not solve the problem. Heavy objects in the water can damage propellers. Where rodents, such as muskrats, can get to plastic propellers, they have been known to cause chewing damage. Propeller meters require continuous inspection and maintenance, which may amount to very little to very much, depending on local conditions and brands selected. Potential users should seek information from other local users before selection. In some cases of high maintenance costs and expensive water, these meters have paid for themselves in as little as 2 months on the basis of water conserved. However, in other areas where water is relatively plentiful, they have never repaid their original cost. Propeller bearing troubles are the most expensive and common problem and may be difficult to overcome except by means of a well-planned maintenance program. Maintenance costs can be excessive if meters are used for water with sediment. Propeller meters require a maintenance routine where bearings are replaced based on time of operation.
5. Bypass Meters
These meters measure part of the total flow which is allowed or forced through a small passageway by differential pressure across a fitting and returned to the main flow. Thus, these meters are sometimes called proportional, or shunt, flowmeters. The side flow drives an indicator or small water measuring device such as a propeller, vane, rotameter, or turbine meter. Indicators of the smaller flowmeter readings are related to total discharge by calibration. These reading devices display or indicate instantaneous rate of flow, totalized volume of flow, or both. Bypass meters are produced and sold commercially with calibrations and discharge tables.
6. Magnetic Flowmeters
The operation of magnetic flowmeters is based upon the principle that a voltage is induced in an electrical conductor moving through a magnetic field. In the case of magnetic flowmeters, the conductor is the flowing water being measured. For a given field strength, the magnitude of the induced voltage is proportional to the velocity of the conductor. The meter consists of a nonmagnetic and non-electrical conducting tube or pipe through which the water flows. Two magnetic coils are used, one on each side of the pipe. Two electrodes in each side of the insulated pipe wall sense the flow-induced voltage. 14-10
The meter should be mounted so that the electrodes are horizontal to prevent air from breaking the voltage measuring circuit. The meter has electrical circuits to transform the induced voltage into a rate-of-flow indication on a meter dial (figure 14-8). The electrical sensing system and uniform flow-through passage allow the magnetic flowmeter to measure flow in both directions.
Figure 14-8 -- Schematic view of a magnetic flowmeter. A source of electrical power is needed to activate the magnetic field, and a transmitter is used to record or send the rate-of-flow signals to desired stations. The water needs sufficient conductivity, but other properties such as temperature, viscosity, density, or solid particles do not change calibration. However, dissolved chemicals can deposit on the electrodes and cause accuracy errors. Some of these meters are provided with wipers or electrolytic or ultrasonic electrode cleaners. Head losses through the meter are negligible, and accuracy of measurement in the upper half of the meter's rated capability is usually good. Later model electromagnetic meters can have good accuracy (+/-1.0%) for a range of minimum to maximum discharge.
7. Deflection Meters
A deflection meter consists of a vane or plate that projects into the flow and a sensing element that measures the deflection caused by the force of the flow against the vane. These meters are sometimes called drag or target meters. They are usually calibrated to indicate the rate of flow in some desired unit of measure. Head losses through the meter are low to moderate, depending upon design. These meters have no pressure taps to plug. The meters are available commercially and are relatively simple. Their accuracy ranges from moderate to good.
8. Variable-Area Meters
In variable-area meters, the water flows vertically upward in a conically tapered tube in which area increases with height. The rate of flow is indicated by the height at which a shaped weight attains stable support from the flow in the tapered tube. Smaller versions are commonly called rotameters because many of the weights are sometimes vaned to rotate for stability in the tapered tube. The weights appear to float freely in the tapered tube. Thus, they are often called floats. When the tube is transparent, the position of the float can be observed directly against graduations on the tube.
14-11
Larger meters sometimes have a stem attached to the float, which is linked mechanically or magnetically to an indicator. Auxiliary recording and transmitting of discharge and totalized volume are sometimes incorporated into these meters. These meters generally have few moving parts to wear or otherwise cause trouble, and the accuracy of the meters can be high. The head losses may be large. These meters have to be installed in a vertical position, making pipe fitting more difficult.
Web Resources
The listings here should not be construed as an endorsement or recommendation of a service or product by the Bureau of Reclamation, Agricultural Research Service, Natural Resource Conservation Service, or other participants of these web pages. These are provided only as a convenience to our web clients. The listing below were selected based on a manufacture statement that they can provide a device related to this chapter or section. To suggest new information for this page, go to the Suggest-A-Link web page. ISA (Instrumentation Society of America, the international society for measurement and control) RP16.4: Nomenclature and Terminology for Extension-Type Variable Area Meters (Rotameters)-1960
http://www.isa.org/?template=Ecommerce/ProductDisplay.cfm&ProductID=2507
Manufactures
FLW Southeast, Inc. 1343 Canton Road Suite D-1 Marietta, GA 30066 Phone: (770) 424-1731 Fax: (770) 424-9733 E-mail: flwse@flwsoutheast.com Related web page: www.flwsoutheast.com
9. Vortex Flowmeter
The vortex generating flowmeter is based on the principle that obstructions placed in flows generate vortex shedding trails in the flow (White and McMurtrie, 1971). A properly shaped obstruction will produce stable vortices that reinforce or interact with each other on each side of the obstruction. The shedding vortex oscillations are sensed in different ways such as by thermistors, pressure cells, or magnetically picking up the oscillation of a shuttle ball in a chamber that has each end connected to each side of the obstruction. The proper shape of the obstruction also produces an oscillation frequency that is proportional to velocity over a large range of flow. Manufacturers cite advantages such as the possibility of no moving parts, calibration by dimensional tolerance limits to +1 percent, large discharge range, and adaptability to electronic digital counting. The meters can be made portable by installing the obstruction through the stuffing boxes. 14-12
Figure 14-9 -- Pitot tubes and manometer. For a velocity measurement, the pressure head is subtracted from the total head, Ht, resulting in velocity head, hv, or V 2/2g. Solving for the velocity of flow, V, results in:
V = C 2 ghv
where:
(14-4)
14-14
The measurement of point velocities is relatively simple. However, partitioning the flow section relative to velocity points is complex, depending on the accuracy desired. The main problem in determining proper partial areas is that each point velocity represents or determines meaningful velocity weighting factors related to each point location. Many schemes can be used to locate measuring points on grids or diameters and assign weighting factors for each position. The procedures are further complicated when corrections are needed to account for the obstruction of rack support systems and the size of the instruments themselves. If accuracies better than +/-3 percent are needed, then procedures set by codes such as ISO (1977) and ASME (1992) should be consulted. Some methods of averaging velocity are done by selecting equal areas related to the shape of the flow cross section and measuring velocity at specific points within these areas. For pitot measurements, the average of the square root of the velocity heads of the point measurements is multiplied by the flow section area. The most common pressure conduit is the circular pipe. For a constant rate of flow, the velocity varies from point to point across the stream, gradually increasing from the walls toward the center of the pipe. The mean velocity is obtained by dividing the cross-sectional area of the pipe into a number of concentric, equal area rings and a central circle. The standard (ASME, 1983) 10-point system is shown on figure 14-10a. More equal area divisions may be used if required by large flow distortions or other unusual flow conditions. Velocity measurements are taken at specific locations in these subareas (figure 14-10a) and are adjusted in terms of average velocity head by the equation:
vavg =
2 g ( hv )avg
(14-5)
Figure 14-10 -- Locations for pitot tube measurements in circular and rectangular conduits (reproduced from British Standard 1042, Flow Measurement [1943], by permission of the British Standards Institution). 14-15
The mean velocity in rectangular ducts can be found by dividing the cross section into an even number (at least 16) of equal rectangles geometrically similar to the duct cross section and measuring the velocity at the center of each area (figure 14-9b). Additional readings should be taken in the areas along the periphery of the cross section according to the diagram on figure 149c. Then, the average velocity is determined from equation 14-5. Acoustic devices, discussed in chapter 11, measure accurate average velocity along chords or diametral lines in planes across the flow section. The diametral arrangement uses the simple average of the line velocities corrected for the angle of the plane across the conduit. The multiple chordal systems use a specific weighting factor for each line velocity to determine the average (AMSE, 1992). The chord locations are specified to maximize accuracy.
Q = 8.69 (1 where:
a 1.88 2.48 ) d d
(14-6)
Q = discharge (ft3/s) a = distance measured in the plane of the end of the pipe from the top of the inside surface of the pipe to the water surface (ft) d = internal diameter of the pipe (ft)
14-16
Figure 14-11 -- Typical arrangement for measuring flow by the California pipe method. This equation, developed from experimental data for pipes 3 to 10 inches in diameter, gives reasonably accurate values of discharge for that range of sizes under certain flow conditions. However, tests by the Natural Resources Conservation Service (formerly U.S. Soil Conservation Service) (Rohwer, 1943) showed that for depths greater than about one-half the diameter of the pipe or a/d less than about 0.5, the discharge does not follow the Vanleer equation. Bos (1989) shows that brink depth must be less than 0.55d, or a/d must be greater than 0.45. Care should therefore be taken in using equation 14-6. The discharge uncertainty of this method is expected to be about +/-10 percent, assuming careful brink depth and pipe diameter measurements. Some additional requirements for proper use and for attaining potential accuracy of the California pipe measurement method are: (1) The discharge pipe must be level. (2) The pipe must be partially full with a/d greater than 0.45. (3) The flow must discharge freely into the air.
Q = 5.01d1.99h0.53
where:
(14-7)
Q = 6.17d1.25h1.35
(14-8)
For jet heights between 0.37d and 1.4d, the flow is considerably less than that given by either of these equations. Figure 14-12, prepared using data from Stock (1955) gives flow rates in gallons per minute for standard pipes 2 to 12 inches in diameter and jet heights from 12 to 60 in. Bos (1989) assigns to this method an accuracy of +/-10 percent for the jet flow range to +/-15 percent for the weir flow range.
Figure 14-12 -- Discharge curves for measurement of flow from vertical standard pipes. The curves are based on data from experiments of Lawrence and Braunworth, American Society of Civil Engineers, Transactions, Vol. 57, 1906 (courtesy of Utah State University). For irrigation convenience, the Natural Resources Conservation Service produced a table from curves for vertical pipes in Stock (1955) for the NRCS National Engineering Handbook (1962a). This table is reproduced here as table 14-1. The table gives discharges for different heads up to 40 in for standard nominal pipe diameters from 2 to 12 inches and for outside diameters of well casings from 4 to 12 inches. As mentioned before, accuracies better than 15 and 10 per-cent should not be expected, depending on whether the flow is acting as a weir or jet-type flow.
14-18
Table prepared from discharge curves in Utah Engineering Experimental Station, Bulletin 5, "Measurement of Irrigation Water," June 1955.
2 3
Figure 14-13 -- Purdue method of measuring flow from a horizontal pipe (courtesy of Utah State University). 14-19
Figure 14-14 -- Flow from horizontal standard pipes by Purdue coordinate method (courtesy of Utah State University) (sheet 1 of 2).
Figure 14-14 -- Flow from horizontal standard pipes by Purdue coordinate method (courtesy of Utah State University) (sheet 2 of 2). The most accurate results will be obtained when the pipe is truly horizontal. If it slopes upward, the indicated discharge will be too high. If it slopes downward, the indicated discharge will be too low. Difficulty occurs in making the vertical measurement, Y, because the top of the jet will usually not be smooth and well defined. The NRCS produced table 14-2 for horizontal pipe discharge for X of 0, 6, 12 and 18 in and Y up to about 8 in for pipe diameters from 2 to 6 in. As mentioned previously, accuracies better than 10 percent should not be expected.
14-20
Table for standard steel pipe prepared from data resulting from actual experiments conducted at Purdue University Experimental Station, Bulletin 32, "Measurement of Pipe Flow by the Coordinate Method," August 1928.
Figure 14-15 -- Discharge through ditch-to-furrow pipes and siphons (figures 14-16 and 14-17) may be determined by measuring the effective head.
14-22
Figure 14-16 -- Rates of flow through ditch-to-furrow pipes for various heads.
for various heads. The pipe ends should be cut cleanly with no burrs. The tubes and ends should not be dented or deformed. Tight bends should be avoided. The flow past either end of the tube must be slow compared to tube velocity. Tubes can become partially or fully air locked at lower discharges of curves shown on figures 14-16 and 1417. The siphons should be reprimed periodically when operating at the low discharge region. Both submerged ends should be located a distance of 1.5 diameters from channel flow boundaries and water surface. If a vortex forms over the siphon entrance, the entrance should be lowered if possible; otherwise, the vortex should be suppressed. The vortex can be suppressed by rafting a wide board over the intake and hanging additional cross vanes from the board if needed. Bos (1989) gives more details concerning these requirements and provides rating curves in metric units. Figure 14-18 (NRCS, 1962a) gives discharge in gallons per minute for heads up to 20 inches for siphon lengths common to furrow irrigation with pipe diameters from 2 to 6 inches. As mentioned previously, accuracies better than 10 percent should not be expected.
Figure 14-18 -- Discharge of aluminum or plastic siphon tubes at various heads for different tube lengths.
This method has recently been applied to shorter, low head turbines (Almquist et al., 1994). The pressure variation is automatically recorded with respect to time on equipment especially devised for this method. Use of the Gibson method requires specially trained personnel. Patents restricting the use of the equipment and method have expired.
18. Bibliography
Almquist, C.W., D.B. Hansen, and P.A. March, Pressure-Time Flow Rate in Low Head Hydro," Proceedings, Symposium on Fundamentals and Advancements in Hydraulic Measurements and Experimentation, Buffalo NY, 1994. American Society of Mechanical Engineers, Fluid Meters, Their Theory and Application, H.S. Bean, editor, sixth edition revised, Research Committee on Fluid Meters, New York, 1983. American Society of Mechanical Engineers, "Performance Test Codes-Hydraulic Turbines and Turbine Mode of Pump/Turbines," revision, Performance Test Code 18, New York NY, 1992. 14-25
Bos, M.G., Discharge Measurement Structures, ILRI Publication 20, Third Revised Edition, Wageningen, The Netherlands, 1989. British Standards Institution, B.S. 1042, Flow Measurement, 1943.Dijstelbergen, H.H., "Gas Meters," In: Developments In Flow
Measurement, R.W.W. Scott (editor), 1982, chapter 5, pp. 129-170, Applied Science Publishers, London. 333 p., 1982.
Furness, R.A., "Developments in Pipeline Instrumentation," in Measurement and Control, No. 20, pp. 25-28, 1987. Gibson, N.R., "The Gibson Method and Apparatus for Measuring the Flow of Water in Closed Conduits," In: Transactions of the American Society of Mechanical Engineers, vol. 45, p. 343, 1923. Greve, F.W., "Measuring of Pipe Flow by the Coordinate Method," Purdue Engineering Experiment Station, Bulletin 32, 1928. Hobbs, M., "Inside the Orifice Plate," Process Engineering, London, vol. 68(2), pp. 33, 35, 1987. Humphreys, J.S., "Improving the Performance of Those Orifice Plates," Process Engineering (London), vol. 68(2), pp. 37, 39, 41, 1987. International Organization for Standardization, Measurement of Fluid Flow in Closed Conduits: Velocity Area Method Using Pitot Tubes, ISO 3966, First Edition, Zurich, Switzerland, 1977. International Organization for Standardization, Measurement of Fluid Flow in Closed Conduits: Velocity Area Method Using Pitot Tubes, ISO 5167-1, 1991. Lawrence, F.E., and P.L. Braunworth, "Fountain Flow of Water in Vertical Pipes," In: Transactions of the American Society of Civil Engineers,vol. 57, pp. 265-306, 1906. Natural Resources Conservation Service, National Engineering Handbook, Part 623, Section 15 (pipe coordinates), Chapter 9, "Measurement of Irrigation Water," 1962a. Natural Resources Conservation Service, National Engineering Handbook, Part 623, Section 15, Chapter 5, "Furrow Irrigation," 1962b. Replogle, J.A., and B.T. Wahlin, "Venturi Meter Construction for Plastic Irrigation Pipelines," Proceedings, Applied Engineering in Agriculture, American Society of Agricultural Engineers,. 10(1):21-26, 1994. Rohwer, C., "Discharge of Pipes Flowing Partly Full," Civil Engineering, American Society of Civil Engineers, 1943. Scott, V.E., and C.E. Houston, "Measuring Irrigation Water," Circular 473, California Agricultural Experiment Station, University of California, 1959. 14-26
Streeter, V.L., Fluid Mechanics, McGraw-Hill, New York NY, 1951. Stock, E.M., "Measuring of Irrigation Water," Bulletin No. 5, Utah State Engineering Experiment Station and Utah Cooperative Extension Service, 1955. Summers, J.B., "Flow Characteristics of 8-, 10-, 12-, and 18-Inch Concrete Fresno Irrigation Meters," Hydraulic Laboratory Report No. HYD-340, Bureau of Reclamation, Denver CO, 1952. Summers, J.B., "Hydraulic Investigations of the Consolidated Irrigation District Venturi-Type Meters," Hydraulic Laboratory Report No. HYD-341, Bureau of Reclamation, Denver CO, 1953. Vanleer, B.R., "The California Pipe Method of Water Measure- ment," Engineering News Record, August 3, 1922, and August 21, 1924. White, R., and McMurtrie, "The Vortex Shedding Flowmeter," Paper 2-16-187, Synposiumon Flow-Its Measurement and Control in Science and Industry, 1971.
14-27
Figure 1 - Forty-five degree mitred bend with pressure taps on the inside and outside of the bend. The pressure differential is related to the square of the velocity. This force results in an increased pressure on the outside of the bend and a decreased pressure on the inside. The pressure difference is proportional to the square of the velocity. The general form of the equation would be : (2) Figure 1 shows recommended pressure tap locations for a mitred bend according to ID Tech, inc. ID Tech sells an "Electronic Flow Calculator" based on an elbow meter. The coefficents of discharge (Cd) for mitred bends (determined empirically by ID Tech) are proprietary. Their toll free phone number is 888-782-0498.
Figure 2 shows a multiple level outlet at Beltzville Dam in Pennsylvania. Differential pressures across opposing pressure taps (P1 and P2) and stream gage measurements were used to develop the rating curve and equation shown in figure 3 (Hart and Pugh, 1975).
Figure 2 - Water Quality Control outlet at Beltzville Dam (Hart and Pugh, 1975). The pressure differential between P1 and P2 was empirically calibrated to obtain a discharge relationship. The elbow meter is used to set desired outlet flows for normal operations.
Figure 3 - Elbow Meter Calibration, Beltzville Dam. Similar empirical relationships could be developed for pipe bends in the field by using a strap on acoustic flowmeter (or another flow measurement method) to obtain the data and develop the equation. One differential pressure transducer would be connected to the high and low pressure taps to measure the differential and obtain flow. This is a simple and relatively accurate device if the pressure taps are properly installed and the "burrs" are cleaned from the inside of the tap. A slight rounding of the edge of the taps helps to improve their performance. As a practical matter, the lower limit of an elbow meter is about 2 ft/s. Pressure differences and discharge measurement accuracy are very low below this velocity. Flow Tech recommends an upper velocity limit of 10 ft/s, this is probably due to seperation at the sharp bend in the mitred elbow. Higher velocities may be allowable for
elbows with a constant radius such as the example in figure 2 and 3. (1) Hart, E. D., and Pugh, C. A. , "Outlet Works for Beltzville Dam, Pohopoco Creek, Pennsylvania," Technical Report H-75-10, U. S. Army Corps of Engineers, Waterways Experiment Station, May, 1975.
Nomenclature
A Ac Ao a B bc C Ca Cc Cd Ce Cv Cva Cvf c D dv E
flow section area contracted area of flow orifice area area average width width Chezy factor, general coefficient, concentration of a tracer, or constant gate angle correction factor contraction coefficient discharge coefficient effective discharge coefficient velocity of approach coefficient coefficient to account for exclusion of approach velocity head velocity coefficient caused by friction loss velocity of sound pipe diameter distance water will travel at a given velocity in a pipe of constant diameter specific energy
E%QCs error in percent comparison standard discharge E%QFS error in percent full-scale discharge e egl F
a subscript denoting "effective" energy grade line Froude number Nom-1
canal freeboard critical Froude number pressure force friction factor gate opening acceleration caused by gravity total energy head critical total energy head head or height measuring head submergence head submergence ratio critical head critical hydraulic mean depth effective measurement head head loss hydraulic mean depth measured velocity head
h1 + k h
head measure above a weir crest (upstream head) upstream head minus downstream head (differential head)
k kb kh L Lb Le N n PH
Pw
boundary roughness size correction factor to obtain effective weir length correction factor to obtain effective head length cross-sectional width
Reynolds number hydraulic radius ratio of suppressed portion of the perimeter of an orifice to total perimeter radius of curvature slope or estimate of standard deviation invert or bottom slope water surface slope estimate of standard deviation time top water surface width top water surface width at critical conditions time downstream travel time of the acoustic signal upstream travel time of the acoustic signal difference in times equation coefficient or exponent mean velocity critical velocity average axial velocity of water flow volume weight mean of a set of values each individual value from a set of values potential energy head Nom-4
ratio of orifice hole diameter to pipe diameter unit weight of water angle kinematic viscosity standard deviation
Nom-5
Conversion Factors
Length Multiply Miles By 1.60935 1,760 5,280 63,360 0.00062137 1.0936 3.28088 39.37 100 0.001 0.9144 0.00056818 3.0 36 0.3048 0.00018939 0.33333 12 0.08333 0.027778 0.000015783 2.54 Area Square miles 4,014,489,600 27,878,400 3,097,600 640 259 208.71 0.404687 0.0015625 4,840 43,560 4,047 0.83613 0.0000003228 0.0002066 9 1,296 0.092903 0.000000003587 0.000022957 0.11111 144 0.0000000002491 6.45163 0.0000001594 0.0007716 0.006944 Volume Acre-feet 325,851 43,560 1,613.3 1,233.49 27 46,656 0.00061983 0.76456 1,728 7.4805 28.317 0.037037 0.000022957 U.S. gallons Cubic feet Cubic yards Cubic meters Cubic feet Cubic inches Acre-feet Cubic meters Cubic inches U.S. gallons Liters Cubic yards Acre-feet Square inches Square feet Square yards Acres Hectares Square feet Hectares Square miles Square yards Square feet Square meters Square miles Acres Square feet Square inches Square meters Square miles Acres Square yards Square inches Square miles Square centimeters Acres Square yards Square feet To obtain Kilometers Yards Feet Inches Miles Yards Feet Inches Centimeters Kilometers Meters Miles Feet Inches Meters Miles Yards Inches Feet Yards Miles Centimeters
Meters
Yards
Feet
Inches
Acres
Square yards
Square feet
Square inches
Cubic yards
Cubic feet
To obtain Cubic inches Liters Cubic feet Acre-feet Cubic centimeters U.S. gallons Cubic feet
Cubic inches
40
38.4 0.028317 1.699 101.941 2,446.58 28.317 1.547 3.07 2.629 0.06309 3.7854
U.S. gallons per minute Cubic feet per minute Cubic feet per hour Cubic feet per day Acre-feet per year Acre-feet per day Acre-inches per hour Miners inch in Idaho, Kansas, Nebraska, South Dakota, North Dakota, New Mexico, Utah, Washington, southern California (customary) Miners inch in Arizona, Montana, Oregon, Nevada, and California (statutory) Miners inch in Colorado Cubic meters per second Cubic meters per minute Cubic meters per hour Cubic meters per day Liters per second Cubic feet per seconda Acre-feet per day Cubic meters per minute Liters per second Liters per minute
Velocity Feet per second 0.68 1.097 30.48 2.540 0.3048 Acceleration Feet per second per second 0.3048 Weight, Mass Pounds, avoirdupois 0.4536 16 7,000 1.21528 1,000 15,432 2.2046 907.185 Kilograms Ounces Grains Pounds, troy Grams Grains Pounds, avoirdupois Kilograms Meters per second per second Miles per hour Kilometers per hour Centimeters per second Centimeters per hour Meters per year
Kilograms
Pounds per square inch Pounds per square foot Feet of water column (at 20 0C)
Horsepower (metric)
4.8824 0.092903
Surface Tension Pounds per foot 1.4882 Gas Constant Feet per degree F 0.5486 Meters per degree Celsius Kilograms per meter
NOTES: 1 ft3/s falling 8.81 feet = 1 horsepower. 1 ft3/s falling 10.0 feet = 1.135 horsepower. 1 ft3/s falling 11.0 feet = 1 horsepower at 80-percent efficiency. 1 ft3/s flowing for 1 year will cover 1 square mile to a depth of 1.131 feet, or 13.572 inches. 1 inch depth of water on 1 square mile = 2,323,200 cubic feet = 0.0737 ft 3/s for 1 year.
a
The cubic foot per second is also commonly referred to as the second-foot.
Sharp-Crest Weirs
A7-2. Discharge of standard contracted rectangular weirs in ft3/sec. A7-3. Discharge of standard suppressed rectangular weirs in ft3/sec. A7-4. Discharge of 90 V-notch weirs, in ft3/sec. A7-5. Discharge of standard Cipolletti weirs in ft3/sec. Shaded entries determined experimentally.
Parshall Flumes
A8-7. Free-flow discharge through 1-inch Parshall measuring flume in ft3/sec. A8-8. Free-flow discharge through 2-inch Parshall measuring flume in ft3/sec. A8-9. Free-flow discharge through 3-inch Parshall measuring flume in ft3/sec. A8-10. Free-flow discharge through 6-inch Parshall measuring flume in ft3/sec. A8-11. Free-flow discharge through 9-inch Parshall measuring flume in ft3/sec. A8-12. Free-flow discharges in ft3/sec through 1- to 8-foot Parshall flumes. A8-13. Free-flow discharge through 10-ft Parshall measuring flume in ft3/sec. A8-14. Free-flow discharge through 12-ft Parshall measuring flume in ft3/sec. A8-15. Free-flow discharge through 15-ft Parshall measuring flume in ft3/sec. A8-16. Free-flow discharge through 20-ft Parshall measuring flume in ft3/sec. A8-17. Free-flow discharge through 25-ft Parshall measuring flume in ft3/sec. A8-18. Free-flow discharge through 30-ft Parshall measuring flume in ft3/sec. A8-19. Free-flow discharge through 40-ft Parshall measuring flume in ft3/sec. A8-20. Free-flow discharge through 50-ft Parshall measuring flume in ft3/sec.
Table A7-2. Discharge of standard contracted rectangular weirs in ft3/sec. Shaded entries determined experimentally. All others computed from the formula Q =3.33(L -0.2h 1)h 11.5.
Head, h 1 ft --------0.18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 .54 .55 .56 .57 .58 .59 .60 0.5 --------0.122 .132 .142 .152 .162 .173 .184 .195 --------------------------------------------------------------------------------------------------------------------------------------------1.0 ----------------0.286 .307 .329 .350 .373 .395 .419 .442 .466 .490 .514 .539 .564 .590 .615 .658 .686 .714 .743 .772 .801 .830 .860 .890 .920 .950 .981 1.01 1.04 1.08 1.11 ----------------------------------------1.5 ----------------0.435 .467 .500 .534 .568 .604 .639 .676 .712 .750 .788 .827 .866 .905 .945 .986 1.03 1.07 1.11 1.15 1.20 1.24 1.28 1.33 1.37 1.42 1.46 1.51 1.55 1.60 1.65 ----------------------------------------Weir Length, L , ft 2.0 3.0 4.0 ----------------0.584 .627 .672 .718 .764 .812 .860 .909 .959 1.01 1.06 1.11 1.17 1.22 1.28 1.33 1.39 1.44 1.50 1.56 1.62 1.68 1.74 1.80 1.86 1.92 1.98 2.05 2.11 2.17 2.24 2.30 2.37 2.43 2.50 2.57 2.63 2.70 2.77 2.84 2.91 ----------------0.882 .948 1.02 1.09 1.16 1.23 1.30 1.38 1.45 1.53 1.61 1.69 1.77 1.85 1.94 2.02 2.11 2.19 2.28 2.37 2.46 2.55 2.64 2.74 2.83 2.93 3.02 3.12 3.22 3.31 3.41 3.51 3.62 3.72 3.82 3.93 4.03 4.14 4.24 4.35 4.46 ----------------1.18 1.27 1.36 1.45 1.55 1.64 1.74 1.84 1.95 2.05 2.16 2.26 2.37 2.48 2.60 2.71 2.83 2.94 3.06 3.18 3.30 3.43 3.55 3.68 3.80 3.93 4.06 4.19 4.32 4.46 4.59 4.73 4.86 5.00 5.14 5.28 5.43 5.57 5.71 5.86 6.00 5.0 ----------------1.48 1.59 1.70 1.82 1.94 2.06 2.18 2.31 2.44 2.57 2.70 2.84 2.98 3.11 3.26 3.40 3.54 3.69 3.84 3.99 4.14 4.30 4.46 4.61 4.77 4.94 5.10 5.26 5.43 5.60 5.77 5.94 6.11 6.29 6.46 6.64 6.82 7.00 7.18 7.37 7.55 6.0 ----------------1.78 1.91 2.05 2.19 2.33 2.48 2.63 2.78 2.93 3.09 3.25 3.41 3.58 3.75 3.92 4.09 4.26 4.44 4.62 4.80 4.99 5.17 5.36 5.55 5.75 5.94 6.14 6.34 6.54 6.74 6.95 7.15 7.36 7.57 7.79 8.00 8.22 8.43 8.65 8.88 9.10 7.0 ----------------2.07 2.23 2.39 2.55 2.72 2.89 3.07 3.25 3.43 3.61 3.80 3.99 4.18 4.38 4.58 4.78 4.98 5.19 5.40 5.61 5.83 6.05 6.27 6.49 6.72 6.95 7.18 7.41 7.65 7.88 8.12 8.37 8.61 8.86 9.11 9.36 9.61 9.87 10.1 10.4 10.6
Table A7-2 [continued]. Discharge of standard contracted rectangular weirs in ft3/sec. Shaded entries determined experimentally. All others computed from the formula Q =3.33(L -0.2h 1)h 11.5
Head, h 1 ft 0.61 .62 .63 .64 .65 .66 .67 .68 .69 .70 .71 .72 .73 .74 .75 .76 .77 .78 .79 .80 .81 .82 .83 .84 .85 .86 .87 .88 .89 .90 .91 .92 .93 .94 .95 .96 .97 .98 .99 1.00 1.01 1.02 1.03 1.04 1.05 2.0 2.98 3.05 3.12 3.19 3.26 3.34 3.41 3.58 3.66 3.74 3.82 3.90 3.98 4.06 4.14 4.22 4.30 4.38 4.46 4.54 4.62 4.70 4.78 4.87 4.96 5.05 5.14 5.23 5.32 5.41 5.50 5.59 5.68 5.77 5.86 5.95 6.04 6.13 6.22 6.31 --------------------3.0 4.57 4.68 4.79 4.90 5.01 5.12 5.23 5.35 5.46 5.58 5.69 5.81 5.93 6.05 6.16 6.28 6.40 6.52 6.65 6.77 6.89 7.01 7.14 7.26 7.39 7.51 7.64 7.76 7.89 8.02 8.15 8.27 8.40 8.53 8.66 8.80 8.93 9.06 9.19 9.32 --------------------4.0 6.15 6.30 6.45 6.60 6.75 6.91 7.06 7.22 7.37 7.53 7.69 7.84 8.00 8.17 8.33 8.49 8.65 8.82 8.98 9.15 9.32 9.49 9.65 9.82 9.99 10.2 10.3 10.5 10.7 10.9 11.0 11.2 11.4 11.6 11.7 11.9 12.1 12.3 12.5 12.7 12.8 13.0 13.2 13.4 13.6 5.0 7.74 7.93 8.12 8.31 8.50 8.69 8.89 9.08 9.28 9.48 9.68 9.88 10.1 10.3 10.5 10.7 10.9 11.1 11.3 11.5 11.7 12.0 12.2 12.4 12.6 12.8 13.0 13.3 13.5 13.7 13.9 14.2 14.4 14.6 14.8 15.1 15.3 15.5 15.8 16.0 16.2 16.5 16.7 16.9 17.2 6.0 9.33 9.55 9.78 10.0 10.2 10.5 10.7 10.9 11.2 11.4 11.7 11.9 12.2 12.4 12.7 12.9 13.2 13.4 13.7 13.9 14.2 14.4 14.7 15.0 15.2 15.5 15.7 16.0 16.3 16.5 16.8 17.1 17.4 17.6 17.9 18.2 18.5 18.8 19.0 19.3 19.6 19.9 20.2 20.5 20.7 7.0 10.9 11.2 11.4 11.7 12.0 12.3 12.5 12.8 13.1 13.4 13.7 13.9 14.2 14.5 14.8 15.1 15.4 15.7 16.0 16.3 16.6 16.9 17.2 17.5 17.8 18.1 18.4 18.8 19.1 19.4 19.7 20.0 20.4 20.7 21.0 21.3 21.7 22.0 22.3 22.6 23.0 23.3 23.6 24.0 24.3
Table A7-2 [continued]. Discharge of standard contracted rectangular weirs in ft3/sec. Shaded entries determined experimentally. All others computed from the formula Q =3.33(L -0.2h 1)h 11.5
Head, h 1 ft 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 1.20 1.21 1.22 1.23 1.24 1.25 1.26 1.27 1.28 1.29 1.30 1.31 1.32 1.33 1.34 1.35 1.36 1.37 1.38 1.39 1.40 1.41 1.42 1.43 1.44 1.45 1.46 1.47 1.48 1.49 1.50 4.0 13.8 14.0 14.1 14.3 14.5 14.7 14.9 15.1 15.3 15.5 15.7 15.9 16.1 16.3 16.5 16.7 16.9 17.1 17.3 17.5 17.7 17.9 18.1 18.3 18.5 18.7 18.9 19.1 --------------------------------------------------------------------Weir Length, L , ft 5.0 6.0 7.0 17.4 17.6 17.9 18.1 18.4 18.6 18.9 19.1 19.3 19.6 19.8 20.1 20.3 20.6 20.8 21.1 21.3 21.6 21.9 22.1 22.4 22.6 22.9 23.1 23.4 23.7 23.9 24.2 24.4 24.7 25.0 25.2 25.5 25.8 26.0 26.3 26.6 26.8 27.1 27.4 27.7 27.9 28.2 28.5 28.8 21.0 21.3 21.6 21.9 22.2 22.5 22.8 23.1 23.4 23.7 24.0 24.3 24.6 24.9 25.2 25.5 25.8 26.1 26.4 26.8 27.1 27.4 27.7 28.0 28.3 28.6 29.0 29.3 29.6 29.9 30.3 30.6 30.9 31.2 31.6 31.9 32.2 32.5 32.9 33.2 33.5 33.9 34.2 34.5 34.9 24.7 25.0 25.4 25.7 26.0 26.4 26.7 27.1 27.4 27.8 28.2 28.5 28.9 29.2 29.6 30.0 30.3 30.7 31.0 31.4 31.8 32.2 32.5 32.9 33.3 33.6 34.0 34.4 34.8 35.2 35.5 35.9 36.3 36.7 37.1 37.5 37.8 38.2 38.6 39.0 39.4 39.8 40.2 40.6 41.0 Head, h 1 ft 1.51 1.52 1.53 1.54 1.55 1.56 1.57 1.58 1.59 1.60 1.61 1.62 1.63 1.64 1.65 1.66 1.67 1.68 1.69 1.70 1.71 1.72 1.73 1.74 1.75 1.76 1.77 1.78 1.79 1.80 1.81 1.82 1.83 1.84 1.85 1.86 1.87 1.88 1.89 1.90 1.91 1.92 1.93 1.94 1.95 5.0 Weir Length, L , ft 6.0 7.0 35.2 35.5 35.9 36.2 36.6 36.9 37.2 37.6 37.9 38.3 38.6 39.0 39.3 39.7 40.0 40.4 40.7 41.1 41.4 41.8 42.1 42.5 42.8 43.2 43.6 43.9 44.3 44.6 45.0 45.4 45.7 46.1 46.4 46.8 47.2 47.5 47.9 48.3 48.6 49.0 49.4 49.8 50.1 50.5 50.9 41.4 41.8 42.2 42.6 43.0 43.4 43.8 44.2 44.6 45.0 45.4 45.8 46.3 46.7 47.1 47.5 47.9 48.3 48.7 49.2 49.6 50.0 50.4 50.8 51.3 51.7 52.1 52.5 53.0 53.4 53.8 54.3 54.7 55.1 55.6 56.0 56.4 56.9 57.3 57.7 58.2 58.6 59.1 59.5 59.9
29.0 29.3 29.6 29.9 30.1 30.4 30.7 31.0 31.3 31.5 31.8 32.1 32.4 32.7 33.0 33.2 33.5 -----------------------------------------------------------------------------------------------------------------
Table A7-2 [continued]. Discharge of standard contracted rectangular weirs in ft3/sec. Shaded entries determined experimentally. All others computed from the formula Q =3.33(L -0.2h 1)h 11.5
Head, h 1 ft 1.96 1.97 1.98 1.99 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.19 2.20 2.21 2.22 2.23 2.24 2.25 2.26 2.27 2.28 2.29 2.30 2.31 2.32 2.33 6.0 51.2 51.6 52.0 52.4 52.7 ------------------------------------------------------------------------------------------------------------------------------------7.0 60.4 60.8 61.3 61.7 62.2 62.6 63.1 63.5 64.0 64.4 64.9 65.3 65.8 66.2 66.7 67.1 67.6 68.1 68.5 69.0 69.4 69.9 70.4 70.8 71.3 71.7 72.2 72.7 73.1 73.6 74.1 74.6 75.0 75.5 76.0 76.4 76.9 77.4
Table A7-2 [continued]. Discharge of standard contracted rectangular weirs in ft3/sec. Shaded entries determined experimentally. All others computed from the formula Q =3.33(L -0.2h 1)h 11.5
Head, h 1 ft ----0.20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 2.60 2.70 2.80 2.90 3.00 3.10 3.20 3.30 3.40 3.50 3.60 3.70 3.80 3.90 4.00 4.10 4.20 4.30 4.40 4.50 8.0 ----2.37 4.34 6.67 9.30 12.2 15.3 18.7 22.2 26.0 29.9 34.0 38.2 42.6 47.1 51.8 56.5 61.4 66.5 71.6 76.8 82.1 87.6 93.1 98.7 104. 110. ------------------------------------------------------------------------9.0 ----2.67 4.89 7.51 10.5 13.7 17.3 21.1 25.1 29.3 33.7 38.3 43.1 48.1 53.2 58.5 63.9 69.5 75.2 81.0 86.9 93.0 99.2 105. 112. 118. 125. 132. 138. 145. ------------------------------------------------------------10.0 ----2.97 5.44 8.36 11.7 15.3 19.2 23.4 27.9 32.6 37.6 42.7 48.1 53.6 59.3 65.2 71.3 77.5 83.9 90.4 97.1 104. 111. 118. 125. 132. 140. 147. 155. 163. 170. 178. 186. ------------------------------------------------Weir Length, L , ft 12.0 15.0 ----3.56 6.53 10.0 14.0 18.4 23.1 28.2 33.6 39.3 45.3 51.5 57.9 64.6 71.6 78.7 86.1 93.6 101. 109. 117. 126. 134. 143. 151. 160. 169. 178. 188. 197. 207. 217. 226. 236. 246. 257. 267. 277. 288. 298. ------------------------4.46 8.17 12.6 17.5 23.0 29.0 35.4 42.1 49.3 56.8 64.6 72.8 81.2 89.9 98.9 108. 118. 128. 138. 148. 158. 169. 180. 191. 202. 214. 225. 237. 249. 261. 274. 286. 299. 312. 325. 338. 351. 365. 378. 392. 406. 420. 434. 448. 18.0 ----5.35 9.82 15.1 21.1 27.7 34.8 42.5 50.7 59.3 68.3 77.7 87.6 97.7 108. 119. 130. 142. 154. 166. 178. 191. 204. 217. 230. 244. 258. 272. 286. 301. 316. 331. 346. 362. 377. 393. 409. 425. 442. 458. 475. 492. 509. 526. 544. 20.0 ----5.94 10.91 16.8 23.4 30.8 38.7 47.3 56.4 65.9 76.0 86.5 97.4 109. 121. 133. 145. 158. 171. 185. 198. 213. 227. 242. 257. 272. 287. 303. 319. 336. 352. 369. 386. 403. 421. 439. 456. 475. 493. 511. 530. 549. 568. 588. 607.
Table A7-3. Discharge of standard suppressed rectangular weirs 3 1.5 in ft /sec. Computed from the formula Q =3.33Lh 1
Head h 1, ft 0.20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 .54 .55 .56 .57 .58 .59 .60 .61 .62 .63 .64 Weir Length, L , ft 2.0 3.0 0.596 .641 .687 .735 .783 .833 .883 .934 .987 1.04 1.09 1.15 1.21 1.26 1.32 1.38 1.44 1.50 1.56 1.62 1.68 1.75 1.81 1.88 1.94 2.01 2.08 2.15 2.21 2.28 2.35 2.43 2.50 2.57 2.64 2.72 2.79 2.87 2.94 3.02 3.10 3.17 3.25 3.33 3.41 0.894 .961 1.03 1.10 1.17 1.25 1.32 1.40 1.48 1.56 1.64 1.72 1.81 1.89 1.98 2.07 2.16 2.25 2.34 2.43 2.53 2.62 2.72 2.82 2.92 3.02 3.12 3.22 3.32 3.43 3.53 3.64 3.75 3.85 3.96 4.07 4.19 4.30 4.41 4.53 4.64 4.76 4.88 5.00 5.11
1.0 0.298 .320 .344 .367 .392 .416 .441 .467 .493 .520 .547 .575 .603 .631 -----------------------------------------------------------------------------------------------------------------------------
1.5 0.447 .481 .515 .551 .587 .624 .662 .701 .740 .780 .821 .862 .904 .947 .990 1.03 1.08 1.12 1.17 1.22 1.26 1.31 1.36 1.41 1.46 1.51 1.56 1.61 1.66 1.71 1.77 ---------------------------------------------------------
4.0 1.19 1.28 1.37 1.47 1.57 1.67 1.77 1.87 1.97 2.08 2.19 2.30 2.41 2.53 2.64 2.76 2.88 3.00 3.12 3.24 3.37 3.50 3.63 3.76 3.89 4.02 4.16 4.29 4.43 4.57 4.71 4.85 4.99 5.14 5.29 5.43 5.58 5.73 5.88 6.04 6.19 6.35 6.50 6.66 6.82
5.0 1.49 1.60 1.72 1.84 1.96 2.08 2.21 2.34 2.47 2.60 2.74 2.87 3.01 3.16 3.30 3.45 3.60 3.75 3.90 4.06 4.21 4.37 4.53 4.69 4.86 5.03 5.19 5.36 5.54 5.71 5.89 6.06 6.24 6.42 6.61 6.79 6.98 7.17 7.35 7.55 7.74 7.93 8.13 8.33 8.52
Table A7-3 [continued]. Discharge of standard suppressed rectangular 3 1.5 weirs in ft /sec. Computed from the formula Q =3.33Lh 1
Head h 1, ft 0.65 .66 .67 .68 .69 .70 .71 .72 .73 .74 .75 .76 .77 .78 .79 .80 .81 .82 .83 .84 .85 .86 .87 .88 .89 .90 .91 .92 .93 .94 .95 .96 .97 .98 .99 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 Weir Length, L , ft 3.0 4.0 5.0 5.24 5.36 5.48 5.60 5.73 5.85 5.98 6.10 6.23 6.36 6.49 6.62 6.75 6.88 7.01 7.15 7.28 7.42 7.55 7.69 7.83 7.97 8.11 8.25 8.39 8.53 8.67 8.82 8.96 9.10 9.25 9.40 9.54 9.69 9.84 9.99 ------------------------------------6.98 7.14 7.30 7.47 7.63 7.80 7.97 8.14 8.31 8.48 8.65 8.83 9.00 9.18 9.35 9.53 9.71 9.89 10.1 10.3 10.4 10.6 10.8 11.0 11.2 11.4 11.6 11.8 11.9 12.1 12.3 12.5 12.7 12.9 13.1 13.3 13.5 13.7 13.9 14.1 14.3 14.5 14.7 14.9 15.2 8.73 8.93 9.13 9.34 9.54 9.75 9.96 10.2 10.4 10.6 10.8 11.0 11.2 11.5 11.7 11.9 12.1 12.4 12.6 12.8 13.0 13.3 13.5 13.7 14.0 14.2 14.5 14.7 14.9 15.2 15.4 15.7 15.9 16.2 16.4 16.7 16.9 17.2 17.4 17.7 17.9 18.2 18.4 18.7 18.9 Head h 1, ft 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 1.20 1.21 1.22 1.23 1.24 1.25 1.26 1.27 1.28 1.29 1.30 1.31 1.32 1.33 1.34 1.35 1.36 1.37 1.38 1.39 1.40 1.41 1.42 1.43 1.44 1.45 1.46 1.47 1.48 1.49 1.50 1.51 1.52 1.53 1.54 Weir Length, L , ft 4.0 5.0 15.4 15.6 15.8 16.0 16.2 16.4 16.6 16.9 17.1 17.3 17.5 17.7 17.9 18.2 18.4 18.6 18.8 19.1 19.3 19.5 19.7 20.0 20.2 20.4 ------------------------------------------------------------------------------------19.2 19.5 19.7 20.0 20.3 20.5 20.8 21.1 21.3 21.6 21.9 22.2 22.4 22.7 23.0 23.3 23.5 23.8 24.1 24.4 24.7 25.0 25.3 25.5 25.8 26.1 26.4 26.7 27.0 27.3 27.6 27.9 28.2 28.5 28.8 29.1 29.4 29.7 30.0 30.3 30.6 30.9 31.2 31.5 31.8 Head h 1, ft 1.55 1.56 1.57 1.58 1.59 1.60 1.61 1.62 1.63 1.64 1.65 1.66 1.67 L 5.0 32.1 32.4 32.8 33.1 33.4 33.7 34.0 34.3 34.6 35.0 35.3 35.6 35.9
Table A7-4. Discharge of 90 V-notch weirs, in ft3/sec, computed from the formula Q =2.49h 12.48.
Head H , ft 0.20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 .54 .55 .56 .57 .58 .59 .60 .61 .62 .63 .64 Discharge Q , ft/sec 0.046 .052 .058 .065 .072 .080 .088 .097 .106 .116 .126 .136 .148 .159 .172 .184 .198 .212 .226 .241 .257 .273 .290 .307 .325 .344 .363 .383 .403 .425 .446 .469 .492 .516 .540 .565 .591 .618 .645 .673 .701 .731 .761 .792 .823 Head H , ft 0.65 .66 .67 .68 .69 .70 .71 .72 .73 .74 .75 .76 .77 .78 .79 .80 .81 .82 .83 .84 .85 .86 .87 .88 .89 .90 .91 .92 .93 .94 .95 .96 .97 .98 .99 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 Discharge Q , ft/sec 0.856 .889 .922 .957 .992 1.03 1.06 1.10 1.14 1.18 1.22 1.26 1.30 1.34 1.39 1.43 1.48 1.52 1.57 1.62 1.66 1.71 1.76 1.81 1.87 1.92 1.97 2.02 2.08 2.14 2.19 2.25 2.31 2.37 2.43 2.49 2.55 2.62 2.68 2.74 2.81 2.88 2.94 3.01 3.08 Head H , ft 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 1.20 1.21 1.22 1.23 1.24 1.25 1.26 1.27 1.28 1.29 1.30 1.31 1.32 1.33 1.34 1.35 1.36 1.37 1.38 1.39 1.40 1.41 1.42 1.43 1.44 1.45 1.46 1.47 1.48 1.49 1.50 1.51 1.52 1.53 1.54 Discharge Q , ft/sec 3.15 3.23 3.30 3.37 3.45 3.52 3.60 3.68 3.75 3.83 3.91 3.99 4.08 4.16 4.25 4.33 4.42 4.50 4.59 4.68 4.77 4.86 4.96 5.05 5.15 5.24 5.34 5.44 5.53 5.63 5.74 5.84 5.94 6.05 6.15 6.26 6.36 6.47 6.58 6.69 6.81 6.92 7.03 7.15 7.27 Head H , ft 1.55 1.56 1.57 1.58 1.59 1.60 1.61 1.62 1.63 1.64 1.65 1.66 1.67 1.68 1.69 1.70 1.71 1.72 1.73 1.74 1.75 1.76 1.77 1.78 1.79 1.80 1.81 1.82 1.83 1.84 1.85 1.86 1.87 1.88 1.89 1.90 1.91 1.92 1.93 1.94 1.95 1.96 1.97 1.98 1.99 Discharge Q , ft/sec 7.38 7.50 7.62 7.74 7.86 7.99 8.11 8.24 8.36 8.49 8.62 8.75 8.88 9.02 9.15 9.28 9.42 9.56 9.70 9.83 9.98 10.1 10.3 10.4 10.6 10.7 10.8 11.0 11.1 11.3 11.4 11.6 11.8 11.9 12.1 12.2 12.4 12.6 12.7 12.9 13.0 13.2 13.4 13.5 13.7
Table A7-5. Discharge of standard Cipolletti weirs in ft/sec. Shaded entries determined experimentally. Others computed from the formula Q =3.367Lh 11.5
Head H , ft --------.18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 .54 .55 .56 .57 .58 .59 .60 Weir Length, L , ft 2.0 3.0 ----------------.602 .648 .695 .743 .792 .842 .893 .945 .998 1.05 1.11 1.16 1.22 1.28 1.34 1.39 1.45 1.52 1.58 1.64 1.70 1.77 1.83 1.90 1.97 2.03 2.10 2.17 2.24 2.31 2.38 2.45 2.53 2.60 2.67 2.75 2.82 2.90 2.97 3.05 3.13 ----------------.903 .972 1.04 1.11 1.19 1.26 1.34 1.42 1.50 1.58 1.66 1.74 1.83 1.91 2.00 2.09 2.18 2.27 2.37 2.46 2.56 2.65 2.75 2.85 2.95 3.05 3.15 3.25 3.36 3.46 3.57 3.68 3.79 3.90 4.01 4.12 4.23 4.35 4.46 4.58 4.69
0.5 --------.129 .139 .151 .162 .174 .186 .200 .214 ---------------------------------------------------------------------------------------------------------------------------------------------
1.0 ----------------.301 .324 .347 .371 .396 .421 .446 .472 .499 .526 .553 .581 .609 .638 .668 .697 .727 .758 .789 .820 .852 .884 .916 .949 .983 1.02 1.05 1.08 1.12 1.16 1.20 -----------------------------------------
1.5 ----------------.452 .486 .521 .557 .594 .631 .670 .709 .748 .789 .830 .872 .914 .957 1.00 1.05 1.09 1.14 1.18 1.23 1.28 1.33 1.37 1.42 1.47 1.52 1.58 1.63 1.68 1.73 1.79 -----------------------------------------
4.0 ----------------1.20 1.30 1.39 1.49 1.58 1.68 1.79 1.89 2.00 2.10 2.21 2.32 2.44 2.55 2.67 2.79 2.91 3.03 3.15 3.28 3.41 3.54 3.67 3.80 3.93 4.07 4.20 4.34 4.48 4.62 4.76 4.91 5.05 5.20 5.34 5.49 5.64 5.80 5.95 6.10 6.26
5.0 ----------------1.51 1.62 1.74 1.86 1.98 2.10 2.23 2.36 2.49 2.63 2.77 2.91 3.05 3.19 3.34 3.49 3.64 3.79 3.94 4.10 4.26 4.42 4.58 4.75 4.91 5.08 5.25 5.42 5.60 5.77 5.95 6.13 6.31 6.50 6.68 6.87 7.05 7.24 7.44 7.63 7.82
Table A7-5 [continued]. Discharge of standard Cipolletti weirs in ft3/sec. Shaded entries determined experimentally. Others computed from the formula Q =3.367Lh 11.5
Head H , ft 0.61 .62 .63 .64 .65 .66 .67 .68 .69 .70 .71 .72 .73 .74 .75 .76 .77 .78 .79 .80 .81 .82 .83 .84 .85 .86 .87 .88 .89 .90 .91 .92 .93 .94 .95 .96 .97 .98 .99 1.00 1.01 1.02 1.03 1.04 1.05 Weir Length, L , ft 3.0 4.0 5.0 4.81 4.93 5.05 5.17 5.29 5.42 5.54 5.66 5.79 5.92 6.04 6.17 6.30 6.43 6.56 6.69 6.82 6.96 7.09 7.23 7.36 7.50 7.64 7.78 7.92 8.06 8.20 8.34 8.48 8.62 8.77 8.91 9.06 9.21 9.35 9.50 9.65 9.80 9.95 10.1 10.5 10.6 10.8 10.9 11.1 6.42 6.57 6.73 6.90 7.06 7.22 7.39 7.55 7.72 7.89 8.06 8.23 8.40 8.57 8.75 8.92 9.10 9.28 9.46 9.64 9.82 10.0 10.2 10.4 10.6 10.7 10.9 11.1 11.3 11.5 11.7 11.9 12.1 12.3 12.5 12.7 12.9 13.1 13.3 13.5 13.7 13.9 14.1 14.3 14.5 8.02 8.22 8.42 8.62 8.82 9.03 9.23 9.44 9.65 9.86 10.1 10.3 10.5 10.7 10.9 11.2 11.4 11.6 11.8 12.0 12.3 12.5 12.7 13.0 13.2 13.4 13.7 13.9 14.1 14.4 14.6 14.9 15.1 15.3 15.6 15.8 16.1 16.3 16.6 16.8 17.1 17.3 17.6 17.9 18.1 Head H , ft 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 1.20 1.21 1.22 1.23 1.24 1.25 1.26 1.27 1.28 1.29 1.30 1.31 1.32 1.33 1.34 1.35 1.36 1.37 1.38 1.39 1.40 1.41 1.42 1.43 1.44 1.45 1.46 1.47 1.48 1.49 1.50 Weir Length, L , ft 3.0 4.0 5.0 11.3 11.4 11.6 11.7 11.9 12.1 12.2 12.4 12.5 12.7 12.9 13.0 13.2 13.4 13.6 13.7 13.9 14.1 14.3 14.4 14.6 14.8 15.0 15.2 15.4 15.5 15.7 15.9 16.1 16.2 16.4 16.6 16.8 17.0 17.2 17.4 17.6 17.8 18.0 18.2 18.3 18.5 18.7 18.9 19.1 14.7 14.9 15.1 15.3 15.5 15.8 16.0 16.2 16.4 16.6 16.8 17.0 17.3 17.5 17.7 17.9 18.1 18.4 18.6 18.8 19.0 19.3 19.5 19.7 20.0 20.2 20.4 20.7 --------------------------------------------------------------------18.4 18.6 18.9 19.2 19.4 19.7 20.0 20.2 20.5 20.8 21.0 21.3 21.6 21.9 22.1 22.4 22.7 23.0 23.2 23.5 23.8 24.1 24.4 24.7 25.0 25.2 25.5 25.8 26.1 26.4 26.7 27.0 27.3 27.6 27.9 28.2 28.5 28.8 29.1 29.4 29.7 30.0 30.3 30.6 30.9 Head H , ft 1.51 1.52 1.53 1.54 1.55 1.56 1.57 1.58 1.59 1.60 1.61 1.62 1.63 1.64 1.65 1.66 1.67 L 5.0 31.2 31.5 31.9 32.2 32.5 32.8 33.1 33.4 33.8 34.1 34.4 34.7 35.0 35.4 35.7 36.0 36.3
2.0 3.21 3.29 3.37 3.45 3.53 3.61 3.69 3.81 3.90 3.98 4.06 4.15 4.24 4.33 4.42 4.51 4.60 4.69 4.78 4.87 4.96 5.05 5.14 5.24 5.34 5.44 5.54 5.64 5.74 5.84 5.94 6.04 6.14 6.25 6.36 6.47 6.58 6.69 6.80 6.91 ---------------------
Table A7-5 [continued]. Discharge of standard Cipolletti weirs in ft3/sec. Shaded entries determined experimentally. Others computed from the formula Q =3.367Lh 11.5
Head H , ft 0.20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 .54 .55 .56 .57 .58 .59 .60 .61 .62 .63 .64 Weir Length, L , ft 7.0 8.0 2.11 2.27 2.43 2.60 2.77 2.95 3.12 3.31 3.49 3.68 3.87 4.07 4.27 4.47 4.67 4.88 5.09 5.30 5.52 5.74 5.96 6.19 6.42 6.65 6.88 7.11 7.35 7.59 7.84 8.08 8.33 8.58 8.84 9.09 9.35 9.61 9.88 10.1 10.4 10.7 11.0 11.2 11.5 11.8 12.1 2.41 2.59 2.78 2.97 3.17 3.37 3.57 3.78 3.99 4.21 4.43 4.65 4.88 5.11 5.34 5.58 5.82 6.06 6.31 6.56 6.81 7.07 7.33 7.60 7.86 8.13 8.40 8.68 8.96 9.24 9.52 9.81 10.1 10.4 10.7 11.0 11.3 11.6 11.9 12.2 12.5 12.8 13.1 13.5 13.8 Head H , ft 0.65 .66 .67 .68 .69 .70 .71 .72 .73 .74 .75 .76 .77 .78 .79 .80 .81 .82 .83 .84 .85 .86 .87 .88 .89 .90 .91 .92 .93 .94 .95 .96 .97 .98 .99 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 Weir Length, L , ft 7.0 8.0 12.4 12.6 12.9 13.2 13.5 13.8 14.1 14.4 14.7 15.0 15.3 15.6 15.9 16.2 16.5 16.9 17.2 17.5 17.8 18.1 18.5 18.8 19.1 19.5 19.8 20.1 20.5 20.8 21.1 21.5 21.8 22.2 22.5 22.9 23.2 23.6 23.9 24.3 24.6 25.0 25.4 25.7 26.1 26.5 26.8 14.1 14.4 14.8 15.1 15.4 15.8 16.1 16.5 16.8 17.1 17.5 17.8 18.2 18.6 18.9 19.3 19.6 20.0 20.4 20.7 21.1 21.5 21.9 22.2 22.6 23.0 23.4 23.8 24.2 24.5 24.9 25.3 25.7 26.1 26.5 26.9 27.3 27.7 28.2 28.6 29.0 29.4 29.8 30.2 30.7
6.0 1.81 1.94 2.08 2.23 2.38 2.53 2.68 2.83 2.99 3.15 3.32 3.49 3.66 3.83 4.01 4.18 4.36 4.55 4.73 4.92 5.11 5.30 5.50 5.70 5.90 6.10 6.30 6.51 6.72 6.93 7.14 7.36 7.58 7.79 8.02 8.24 8.47 8.69 8.92 9.16 9.39 9.62 9.86 10.1 10.3
9.0 2.71 2.92 3.13 3.34 3.56 3.79 4.02 4.25 4.49 4.73 4.98 5.23 5.49 5.74 6.01 6.27 6.55 6.82 7.10 7.38 7.67 7.96 8.25 8.54 8.84 9.15 9.45 9.76 10.1 10.4 10.7 11.0 11.4 11.7 12.0 12.4 12.7 13.0 13.4 13.7 14.1 14.4 14.8 15.2 15.5
6.0 10.6 10.8 11.1 11.3 11.6 11.8 12.1 12.3 12.6 12.9 13.1 13.4 13.6 13.9 14.2 14.5 14.7 15.0 15.3 15.6 15.8 16.1 16.4 16.7 17.0 17.2 17.5 17.8 18.1 18.4 18.7 19.0 19.3 19.6 19.9 20.2 20.5 20.8 21.1 21.4 21.7 22.0 22.4 22.7 23.0
9.0 15.9 16.2 16.6 17.0 17.4 17.7 18.1 18.5 18.9 19.3 19.7 20.1 20.5 20.9 21.3 21.7 22.1 22.5 22.9 23.3 23.7 24.2 24.6 25.0 25.4 25.9 26.3 26.7 27.2 27.6 28.1 28.5 28.9 29.4 29.8 30.3 30.8 31.2 31.7 32.1 32.6 33.1 33.5 34.0 34.5
Table A7-5 [continued]. Discharge of standard Cipolletti weirs in ft3/sec. Shaded entries determined experimentally. Others computed from the formula Q =3.367Lh 11.5
Head H , ft 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 1.20 1.21 1.22 1.23 1.24 1.25 1.26 1.27 1.28 1.29 1.30 1.31 1.32 1.33 1.34 1.35 1.36 1.37 1.38 1.39 1.40 1.41 1.42 1.43 1.44 1.45 1.46 1.47 1.48 1.49 1.50 1.51 1.52 1.53 1.54 Weir Length, L , ft 7.0 8.0 27.2 27.6 27.9 28.3 28.7 29.1 29.4 29.8 30.2 30.6 31.0 31.4 31.8 32.2 32.5 32.9 33.3 33.7 34.1 34.5 34.9 35.3 35.7 36.2 36.6 37.0 37.4 37.8 38.2 38.6 39.0 39.5 39.9 40.3 40.7 41.2 41.6 42.0 42.4 42.9 43.3 43.7 44.2 44.6 45.0 31.1 31.5 31.9 32.4 32.8 33.2 33.7 34.1 34.5 35.0 35.4 35.9 36.3 36.7 37.2 37.6 38.1 38.6 39.0 39.5 39.9 40.4 40.9 41.3 41.8 42.3 42.7 43.2 43.7 44.1 44.6 45.1 45.6 46.1 46.5 47.0 47.5 48.0 48.5 49.0 49.5 50.0 50.5 51.0 51.5 Head H , ft 1.55 1.56 1.57 1.58 1.59 1.60 1.61 1.62 1.63 1.64 1.65 1.66 1.67 1.68 1.69 1.70 1.71 1.72 1.73 1.74 1.75 1.76 1.77 1.78 1.79 1.80 1.81 1.82 1.83 1.84 1.85 1.86 1.87 1.88 1.89 1.90 1.91 1.92 1.93 1.94 1.95 1.96 1.97 1.98 1.99 Weir Length, L , ft 7.0 8.0 45.5 45.9 46.4 46.8 47.3 47.7 48.1 48.6 49.0 49.5 50.0 50.4 50.9 51.3 51.8 52.2 52.7 53.2 53.6 54.1 54.6 55.0 55.5 56.0 56.4 56.9 57.4 57.9 58.3 58.8 59.3 59.8 60.3 60.8 61.2 61.7 62.2 62.7 63.2 63.7 64.2 64.7 65.2 65.7 66.2 52.0 52.5 53.0 53.5 54.0 54.5 55.0 55.5 56.1 56.6 57.1 57.6 58.1 58.7 59.2 59.7 60.2 60.8 61.3 61.8 62.4 62.9 63.4 64.0 64.5 65.0 65.6 66.1 66.7 67.2 67.8 68.3 68.9 69.4 70.0 70.5 71.1 71.7 72.2 72.8 73.3 73.9 74.5 75.0 75.6
6.0 23.3 23.6 23.9 24.3 24.6 24.9 25.2 25.6 25.9 26.2 26.6 26.9 27.2 27.6 27.9 28.2 28.6 28.9 29.3 29.6 29.9 30.3 30.6 31.0 31.3 31.7 32.0 32.4 32.8 33.1 33.5 33.8 34.2 34.5 34.9 35.3 35.6 36.0 36.4 36.7 37.1 37.5 37.9 38.2 38.6
9.0 35.0 35.4 35.9 36.4 36.9 37.4 37.9 38.3 38.8 39.3 39.8 40.3 40.8 41.3 41.8 42.3 42.9 43.4 43.9 44.4 44.9 45.4 46.0 46.5 47.0 47.5 48.1 48.6 49.1 49.7 50.2 50.7 51.3 51.8 52.4 52.9 53.5 54.0 54.6 55.1 55.7 56.2 56.8 57.3 57.9
6.0 39.0 39.4 39.7 40.1 40.5 40.9 41.3 41.7 42.0 42.4 42.8 43.2 43.6 44.0 44.4 44.8 45.2 45.6 46.0 46.4 46.8 47.2 47.6 48.0 48.4 48.8 49.2 49.6 50.0 50.4 50.8 51.2 51.7 52.1 52.5 52.9 53.3 53.7 54.2 54.6 55.0 55.4 55.9 56.3 56.7
9.0 58.5 59.0 59.6 60.2 60.8 61.3 61.9 62.5 63.1 63.6 64.2 64.8 65.4 66.0 66.6 67.2 67.8 68.4 69.0 69.6 70.2 70.8 71.4 72.0 72.6 73.2 73.8 74.4 75.0 75.6 76.3 76.9 77.5 78.1 78.7 79.4 80.0 80.6 81.2 81.9 82.5 83.2 83.8 84.4 85.1
Table A7-5 [continued]. Discharge of standard Cipolletti weirs in ft3/sec. Shaded entries determined experimentally. Others computed from the formula Q =3.367Lh 11.5
Head H , ft 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.19 2.20 2.21 2.22 2.23 2.24 2.25 2.26 2.27 2.28 2.29 2.30 2.31 2.32 2.33 2.34 2.35 2.36 2.37 2.38 2.39 2.40 2.41 2.42 2.43 2.44 Weir Length, L , ft 7.0 8.0 66.7 67.2 67.7 68.2 68.7 69.2 69.7 70.2 70.7 71.2 71.7 72.2 72.8 73.3 73.8 74.3 74.8 75.3 75.9 76.4 76.9 77.4 78.0 78.5 79.0 79.5 80.1 80.6 81.1 81.7 82.2 82.7 83.3 83.8 --------------------------------------------76.2 76.8 77.3 77.9 78.5 79.1 79.6 80.2 80.8 81.4 82.0 82.6 83.1 83.7 84.3 84.9 85.5 86.1 86.7 87.3 87.9 88.5 89.1 89.7 90.3 90.9 91.5 92.1 92.7 93.3 94.0 94.6 95.2 95.8 96.4 97.0 97.7 98.3 98.9 100. 100. 101. 101. 102. 103. Head H , ft 2.45 2.46 2.47 2.48 2.49 2.50 2.51 2.52 2.53 2.54 2.55 2.56 2.57 2.58 2.59 2.60 2.61 2.62 2.63 2.64 2.65 2.66 2.67 2.68 2.69 2.70 2.71 2.72 2.73 2.74 2.75 2.76 2.77 2.78 2.79 2.80 2.81 2.82 2.83 2.84 2.85 2.86 2.87 2.88 2.89 L , ft 8.0 103. 104. 105. 105. 106. 106. 107. 108. 108. 109. 110. 110. 111. 112. 112. 113. 114. 114. 115. 116. 116. 117. 118. ----------------------------------------------------------------------------------------9.0 116. 117. 118. 118. 119. 120. 121. 121. 122. 123. 123. 124. 125. 126. 126. 127. 128. 129. 129. 130. 131. 131. 132. 133. 134. 134. 135. 136. 137. 137. 138. 139. 140. 140. 141. 142. 143. 144. 144. 145. 146. 147. 147. 148. 149. Head H , ft 2.90 2.91 2.92 2.93 2.94 2.95 2.96 2.97 2.98 2.99 3.00 L 9.0 150. 150. 151. 152. 153. 154. 154. 155. 156. 157. 157.
9.0 85.7 86.4 87.0 87.6 88.3 88.9 89.6 90.2 90.9 91.6 92.2 92.9 93.5 94.2 94.9 95.5 96.2 96.9 97.5 98.2 98.9 100. 100. 101. 102. 102. 103. 104. 104. 105. 106. 106. 107. 108. 108. 109. 110. 111. 111. 112. 113. 113. 114. 115. 115.
Table A8-7. Free-flow discharge through 1-inch Parshall measuring flume in ft3/sec. Computed from the formula Q =0.338h a1.55.
Upper Head h a, ft 0.00 0.10 0.20 0.30 0.40 0.50 0.60
Hundredths 0.04 0.05 ----0.0160 .037 .063 .095 .130 .169 0.0033 .0179 .039 .066 .098 .134 .173
Table A8-8. Free-flow discharge through 2-inch Parshall measuring flume in ft3/sec. Computed from the formula Q =0.676h a1.55.
Upper Head h a, ft 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70
Hundredths 0.04 0.05 ----0.0321 .074 .127 .189 .260 .338 .424 0.0065 .0357 .079 .133 .196 .268 .347 .433
Table A8-9. Free-flow discharge through 3-inch Parshall measuring flume in ft3/sec. Computed from the formula Q =0.992h a1.55.
Upper Head h a, ft 0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00
0.00 ----0.0280 .082 .153 .240 .339 .449 .571 .702 .843 .992
0.01 ----0.0324 .088 .161 .249 .349 .461 .583 .716 .857 1.007
0.02 ----0.0371 .095 .170 .259 .360 .473 .596 .729 .872 1.023
0.03 ----0.0420 .102 .178 .268 .371 .485 .609 .743 .886 1.039
Hundredths 0.04 0.05 ----0.0471 .109 .186 .278 .382 .497 .622 .757 .901 1.054 0.0095 .0524 .116 .195 .288 .393 .509 .635 .771 .916 1.070
0.06 0.0127 .0579 .123 .204 .298 .404 .521 .648 .785 .931 1.086
0.07 0.0161 .0636 .130 .212 .308 .415 .533 .662 .799 .946 1.102
0.08 0.0198 .0695 .138 .221 .318 .426 .546 .675 .814 .961 1.118
0.09 0.0237 .0756 .146 .230 .328 .438 .558 .688 .828 .977 1.134
Table A8-10. Free-flow discharge through 6-inch Parshall measuring flume in ft /sec. Computed from the formula Q =2.06h a
3 1.58
Upper Head h a, ft 0.10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.20
0.00 0.05 .16 .31 .48 .69 .92 1.17 1.45 1.74 2.06 2.39 2.75
0.01 0.06 .17 .32 .50 .71 .94 1.20 1.48 1.77 2.09 2.43 2.78
0.02 0.07 .19 .34 .52 .73 .97 1.23 1.51 1.81 2.13 2.46 2.82
0.03 0.08 .20 .36 .54 .76 .99 1.25 1.53 1.84 2.16 2.50 2.86
Hundredths 0.04 0.05 0.09 .22 .37 .56 .78 1.02 1.28 1.56 1.87 2.19 2.53 2.89 0.10 .23 .39 .58 .80 1.04 1.31 1.59 1.90 2.23 2.57 2.93
0.06 0.11 .25 .41 .60 .82 1.07 1.34 1.62 1.93 2.26 2.60 2.97
0.07 0.13 .26 .43 .62 .85 1.09 1.36 1.65 1.96 2.29 2.64 3.01
0.08 0.14 .28 .45 .65 .87 1.12 1.39 1.68 2.00 2.33 2.68 3.04
0.09 0.15 .29 .47 .67 .89 1.15 1.42 1.71 2.03 2.36 2.71 3.08
Table A8-11. Free-flow discharge through 9-inch Parshall measuring flume in ft3/sec. Computed from the formula Q =3.07h a1.53
Upper Head h a, ft 0.10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.20 1.30 1.40 1.50
0.00 0.09 .26 .49 .76 1.06 1.41 1.78 2.18 2.61 3.07 3.55 4.06 4.59 5.14 5.71
0.01 0.10 .28 .51 .78 1.10 1.44 1.82 2.22 2.66 3.12 3.60 4.11 4.64 5.19 5.77
0.02 0.12 .30 .54 .81 1.13 1.48 1.86 2.27 2.70 3.16 3.65 4.16 4.69 5.25 5.83
0.03 0.14 .32 .56 .84 1.16 1.51 1.90 2.31 2.75 3.21 3.70 4.21 4.75 5.31 5.88
Hundredths 0.04 0.05 0.15 .35 .59 .87 1.20 1.55 1.94 2.35 2.79 3.26 3.75 4.27 4.80 5.36 5.94 0.17 .37 .62 .90 1.23 1.59 1.98 2.39 2.84 3.31 3.80 4.32 4.86 5.42 6.00
0.06 0.19 .39 .64 .94 1.26 1.63 2.02 2.44 2.88 3.36 3.85 4.37 4.91 5.48 6.06
0.07 0.20 .41 .67 .97 1.30 1.66 2.06 2.48 2.93 3.40 3.90 4.43 4.97 5.54 6.12
0.08 0.22 .44 .70 1.00 1.33 1.70 2.10 2.52 2.98 3.45 3.95 4.48 5.03 5.59 6.18
0.09 0.24 .46 .73 1.03 1.37 1.74 2.14 2.57 3.02 3.50 4.01 4.53 5.08 5.65 6.24
Table A8-12 [continued]. Free-flow discharges in ft3/sec through 1- to 8-foot Parshall flumes. Discharges for 2- to 8-ft flumes computed from the formula Q =4.00Wh a1.522(W ^0.026). Discharges for 1-ft flume computed from the formula Q =3.95h a
1.55
Upper Head
h a, ft 0.20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 .54 .55 .56 .57 .58 .59
1.0 0.33 .35 .38 .40 .43 .46 .49 .52 .55 .58 .61 .64 .68 .71 .74 .78 .81 .85 .88 .92 .95 .99 1.03 1.07 1.11 1.15 1.19 1.23 1.27 1.31 1.35 1.39 1.43 1.48 1.52 1.56 1.61 1.65 1.70 1.74
2.0 0.66 .71 .77 .82 .88 .93 .99 1.05 1.11 1.17 1.24 1.30 1.37 1.44 1.50 1.57 1.64 1.71 1.79 1.86 1.93 2.01 2.09 2.16 2.24 2.32 2.40 2.48 2.57 2.65 2.73 2.82 2.90 2.99 3.08 3.17 3.26 3.35 3.44 3.53
3.0 0.96 1.04 1.12 1.20 1.28 1.37 1.46 1.54 1.63 1.73 1.82 1.92 2.01 2.11 2.22 2.32 2.42 2.53 2.64 2.75 2.86 2.97 3.08 3.20 3.32 3.44 3.56 3.68 3.80 3.93 4.05 4.18 4.31 4.44 4.57 4.71 4.84 4.98 5.11 5.25
4.0 1.26 1.36 1.47 1.57 1.68 1.80 1.91 2.03 2.15 2.27 2.39 2.52 2.65 2.78 2.92 3.05 3.19 3.33 3.48 3.62 3.77 3.92 4.07 4.22 4.38 4.54 4.70 4.86 5.03 5.19 5.36 5.53 5.70 5.88 6.05 6.23 6.41 6.59 6.77 6.96
5.0 --------------------2.22 2.36 2.50 2.65 2.80 2.96 3.12 3.28 3.44 3.61 3.78 3.95 4.13 4.31 4.49 4.67 4.86 5.05 5.24 5.43 5.63 5.83 6.03 6.24 6.45 6.66 6.87 7.08 7.30 7.52 7.74 7.97 8.20 8.43 8.66
6.0 --------------------2.63 2.80 2.97 3.15 3.33 3.52 3.71 3.90 4.10 4.30 4.50 4.71 4.92 5.13 5.35 5.57 5.79 6.02 6.25 6.48 6.72 6.96 7.20 7.45 7.69 7.95 8.20 8.46 8.72 8.98 9.25 9.52 9.79 10.1 10.3
7.0 ----------------------------------------4.07 4.29 4.52 4.75 4.98 5.21 5.46 5.70 5.95 6.20 6.46 6.72 6.98 7.25 7.52 7.80 8.08 8.36 8.65 8.94 9.23 9.53 9.83 10.1 10.4 10.8 11.1 11.4 11.7 12.0
8.0 ----------------------------------------4.63 4.88 5.13 5.39 5.66 5.92 6.20 6.48 6.76 7.05 7.34 7.64 7.94 8.25 8.56 8.87 9.19 9.51 9.84 10.2 10.5 10.8 11.2 11.5 11.9 12.2 12.6 13.0 13.3 13.7
Table A8-12 [continued]. Free-flow discharges in ft3/sec through 1- to 8-foot Parshall flumes. Discharges for 2- to 8-ft flumes computed from the formula Q =4.00Wh a1.522(W ^0.026). Discharges for 1-ft flume computed from the formula Q =3.95h a
1.55
Upper Head
h a, ft 0.60 .61 .62 .63 .64 .65 .66 .67 .68 .69 .70 .71 .72 .73 .74 .75 .76 .77 .78 .79 .80 .81 .82 .83 .84 .85 .86 .87 .88 .89 .90 .91 .92 .93 .94 .95 .96 .97 .98 .99
1.0 1.79 1.84 1.88 1.93 1.98 2.03 2.07 2.12 2.17 2.22 2.27 2.32 2.37 2.43 2.48 2.53 2.58 2.63 2.69 2.74 2.80 2.85 2.90 2.96 3.01 3.07 3.13 3.18 3.24 3.30 3.35 3.41 3.47 3.53 3.59 3.65 3.71 3.77 3.83 3.89
2.0 3.62 3.72 3.81 3.91 4.01 4.10 4.20 4.30 4.40 4.50 4.60 4.71 4.81 4.91 5.02 5.12 5.23 5.34 5.44 5.55 5.66 5.77 5.88 5.99 6.11 6.22 6.33 6.45 6.56 6.68 6.79 6.91 7.03 7.15 7.27 7.39 7.51 7.63 7.75 7.88
3.0 5.39 5.53 5.68 5.82 5.97 6.11 6.26 6.41 6.56 6.71 6.86 7.02 7.17 7.33 7.49 7.65 7.81 7.97 8.13 8.30 8.46 8.63 8.79 8.96 9.13 9.30 9.48 9.65 9.82 10.0 10.2 10.4 10.5 10.7 10.9 11.1 11.3 11.4 11.6 11.8
4.0 7.15 7.34 7.53 7.72 7.91 8.11 8.31 8.51 8.71 8.91 9.11 9.32 9.53 9.74 9.95 10.2 10.4 10.6 10.8 11.0 11.3 11.5 11.7 11.9 12.2 12.4 12.6 12.8 13.1 13.3 13.5 13.8 14.0 14.3 14.5 14.8 15.0 15.2 15.5 15.7
5.0 8.89 9.13 9.37 9.61 9.85 10.1 10.3 10.6 10.8 11.1 11.4 11.6 11.9 12.1 12.4 12.7 12.9 13.2 13.5 13.8 14.0 14.3 14.6 14.9 15.2 15.5 15.7 16.0 16.3 16.6 16.9 17.2 17.5 17.8 18.1 18.4 18.7 19.1 19.4 19.7
6.0 10.6 10.9 11.2 11.5 11.8 12.1 12.4 12.7 13.0 13.3 13.6 13.9 14.2 14.5 14.8 15.2 15.5 15.8 16.1 16.5 16.8 17.2 17.5 17.8 18.2 18.5 18.9 19.2 19.6 19.9 20.3 20.6 21.0 21.4 21.7 22.1 22.5 22.9 23.2 23.6
7.0 12.4 12.7 13.0 13.4 13.7 14.0 14.4 14.7 15.1 15.5 15.8 16.2 16.5 16.9 17.3 17.7 18.0 18.4 18.8 19.2 19.6 20.0 20.4 20.8 21.2 21.6 22.0 22.4 22.8 23.2 23.7 24.1 24.5 24.9 25.4 25.8 26.2 26.7 27.1 27.6
8.0 14.1 14.5 14.8 15.2 15.6 16.0 16.4 16.8 17.2 17.6 18.0 18.5 18.9 19.3 19.7 20.2 20.6 21.0 21.5 21.9 22.4 22.8 23.3 23.7 24.2 24.6 25.1 25.6 26.1 26.5 27.0 27.5 28.0 28.5 29.0 29.5 30.0 30.5 31.0 31.5
Table A8-12 [continued]. Free-flow discharges in ft3/sec through 1- to 8-foot Parshall flumes. Discharges for 2- to 8-ft flumes computed from the formula Q =4.00Wh a1.522(W ^0.026). Discharges for 1-ft flume computed from the formula Q =3.95h a
1.55
Upper Head
h a, ft 1.00 1.01 1.02 1.03 1.04 1.05 1.06 1.07 1.08 1.09 1.10 1.11 1.12 1.13 1.14 1.15 1.16 1.17 1.18 1.19 1.20 1.21 1.22 1.23 1.24 1.25 1.26 1.27 1.28 1.29 1.30 1.31 1.32 1.33 1.34 1.35 1.36 1.37 1.38 1.39
1.0 3.95 4.01 4.07 4.14 4.20 4.26 4.32 4.39 4.45 4.51 4.58 4.64 4.71 4.77 4.84 4.91 4.97 5.04 5.11 5.17 5.24 5.31 5.38 5.44 5.51 5.58 5.65 5.72 5.79 5.86 5.93 6.00 6.07 6.15 6.22 6.29 6.36 6.43 6.51 6.58
2.0 8.00 8.12 8.25 8.37 8.50 8.63 8.76 8.88 9.01 9.14 9.27 9.40 9.54 9.67 9.80 9.93 10.1 10.2 10.3 10.5 10.6 10.7 10.9 11.0 11.2 11.3 11.4 11.6 11.7 11.9 12.0 12.2 12.3 12.4 12.6 12.7 12.9 13.0 13.2 13.3
3.0 12.0 12.2 12.4 12.6 12.8 13.0 13.1 13.3 13.5 13.7 13.9 14.1 14.3 14.5 14.7 14.9 15.1 15.3 15.6 15.8 16.0 16.2 16.4 16.6 16.8 17.0 17.2 17.4 17.7 17.9 18.1 18.3 18.5 18.8 19.0 19.2 19.4 19.6 19.9 20.1
4.0 16.0 16.3 16.5 16.8 17.0 17.3 17.5 17.8 18.1 18.3 18.6 18.9 19.1 19.4 19.7 19.9 20.2 20.5 20.8 21.1 21.3 21.6 21.9 22.2 22.5 22.8 23.0 23.3 23.6 23.9 24.2 24.5 24.8 25.1 25.4 25.7 26.0 26.3 26.6 26.9
5.0 20.0 20.3 20.6 21.0 21.3 21.6 21.9 22.3 22.6 22.9 23.3 23.6 23.9 24.3 24.6 25.0 25.3 25.7 26.0 26.4 26.7 27.1 27.4 27.8 28.1 28.5 28.9 29.2 29.6 30.0 30.3 30.7 31.1 31.4 31.8 32.2 32.6 33.0 33.3 33.7
6.0 24.0 24.4 24.8 25.2 25.5 25.9 26.3 26.7 27.1 27.5 27.9 28.3 28.8 29.2 29.6 30.0 30.4 30.8 31.2 31.7 32.1 32.5 33.0 33.4 33.8 34.3 34.7 35.1 35.6 36.0 36.5 36.9 37.4 37.8 38.3 38.7 39.2 39.6 40.1 40.6
7.0 28.0 28.4 28.9 29.4 29.8 30.3 30.7 31.2 31.7 32.1 32.6 33.1 33.6 34.1 34.5 35.0 35.5 36.0 36.5 37.0 37.5 38.0 38.5 39.0 39.5 40.0 40.5 41.1 41.6 42.1 42.6 43.1 43.7 44.2 44.7 45.3 45.8 46.3 46.9 47.4
8.0 32.0 32.5 33.0 33.6 34.1 34.6 35.1 35.7 36.2 36.8 37.3 37.8 38.4 38.9 39.5 40.1 40.6 41.2 41.7 42.3 42.9 43.5 44.0 44.6 45.2 45.8 46.4 47.0 47.6 48.2 48.8 49.4 50.0 50.6 51.2 51.8 52.4 53.1 53.7 54.3
Table A8-12 [continued]. Free-flow discharges in ft3/sec through 1- to 8-foot Parshall flumes. Discharges for 2- to 8-ft flumes computed from the formula Q =4.00Wh a1.522(W ^0.026). Discharges for 1-ft flume computed from the formula Q =3.95h a
1.55
Upper Head
h a, ft 1.40 1.41 1.42 1.43 1.44 1.45 1.46 1.47 1.48 1.49 1.50 1.51 1.52 1.53 1.54 1.55 1.56 1.57 1.58 1.59 1.60 1.61 1.62 1.63 1.64 1.65 1.66 1.67 1.68 1.69 1.70 1.71 1.72 1.73 1.74 1.75 1.76 1.77 1.78 1.79
1.0 6.65 6.73 6.80 6.88 6.95 7.03 7.10 7.18 7.25 7.33 7.41 7.48 7.56 7.64 7.71 7.79 7.87 7.95 8.03 8.11 8.18 8.26 8.34 8.42 8.50 8.58 8.66 8.75 8.83 8.91 8.99 9.07 9.16 9.24 9.32 9.40 9.49 9.57 9.65 9.74
2.0 13.5 13.6 13.8 13.9 14.1 14.2 14.4 14.5 14.7 14.8 15.0 15.2 15.3 15.5 15.6 15.8 15.9 16.1 16.3 16.4 16.6 16.7 16.9 17.1 17.2 17.4 17.5 17.7 17.9 18.0 18.2 18.4 18.5 18.7 18.9 19.0 19.2 19.4 19.6 19.7
3.0 20.3 20.6 20.8 21.0 21.2 21.5 21.7 21.9 22.2 22.4 22.6 22.9 23.1 23.4 23.6 23.8 24.1 24.3 24.6 24.8 25.1 25.3 25.5 25.8 26.0 26.3 26.5 26.8 27.0 27.3 27.5 27.8 28.1 28.3 28.6 28.8 29.1 29.3 29.6 29.9
4.0 27.2 27.5 27.8 28.1 28.4 28.8 29.1 29.4 29.7 30.0 30.3 30.7 31.0 31.3 31.6 31.9 32.3 32.6 32.9 33.3 33.6 33.9 34.3 34.6 34.9 35.3 35.6 35.9 36.3 36.6 37.0 37.3 37.6 38.0 38.3 38.7 39.0 39.4 39.7 40.1
5.0 34.1 34.5 34.9 35.3 35.7 36.1 36.5 36.9 37.3 37.7 38.1 38.5 38.9 39.3 39.7 40.1 40.5 40.9 41.3 41.7 42.2 42.6 43.0 43.4 43.9 44.3 44.7 45.1 45.6 46.0 46.4 46.9 47.3 47.7 48.2 48.6 49.1 49.5 49.9 50.4
6.0 41.0 41.5 42.0 42.5 42.9 43.4 43.9 44.4 44.8 45.3 45.8 46.3 46.8 47.3 47.8 48.3 48.8 49.3 49.8 50.3 50.8 51.3 51.8 52.3 52.8 53.3 53.9 54.4 54.9 55.4 55.9 56.5 57.0 57.5 58.0 58.6 59.1 59.7 60.2 60.7
7.0 48.0 48.5 49.1 49.6 50.2 50.8 51.3 51.9 52.4 53.0 53.6 54.2 54.7 55.3 55.9 56.5 57.1 57.6 58.2 58.8 59.4 60.0 60.6 61.2 61.8 62.4 63.0 63.6 64.3 64.9 65.5 66.1 66.7 67.3 68.0 68.6 69.2 69.8 70.5 71.1
8.0 54.9 55.6 56.2 56.8 57.5 58.1 58.8 59.4 60.1 60.7 61.4 62.0 62.7 63.4 64.0 64.7 65.4 66.1 66.7 67.4 68.1 68.8 69.5 70.2 70.8 71.5 72.2 72.9 73.6 74.3 75.1 75.8 76.5 77.2 77.9 78.6 79.4 80.1 80.8 81.5
Table A8-12 [continued]. Free-flow discharges in ft3/sec through 1- to 8-foot Parshall flumes. Discharges for 2- to 8-ft flumes computed from the formula Q =4.00Wh a1.522(W ^0.026). Discharges for 1-ft flume computed from the formula Q =3.95h a
1.55
Upper Head
h a, ft 1.80 1.81 1.82 1.83 1.84 1.85 1.86 1.87 1.88 1.89 1.90 1.91 1.92 1.93 1.94 1.95 1.96 1.97 1.98 1.99 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.19
1.0 9.82 9.91 9.99 10.1 10.2 10.2 10.3 10.4 10.5 10.6 10.7 10.8 10.9 10.9 11.0 11.1 11.2 11.3 11.4 11.5 11.6 11.7 11.7 11.8 11.9 12.0 12.1 12.2 12.3 12.4 12.5 12.6 12.7 12.8 12.8 12.9 13.0 13.1 13.2 13.3
2.0 19.9 20.1 20.2 20.4 20.6 20.8 20.9 21.1 21.3 21.5 21.6 21.8 22.0 22.2 22.3 22.5 22.7 22.9 23.1 23.2 23.4 23.6 23.8 24.0 24.1 24.3 24.5 24.7 24.9 25.1 25.3 25.4 25.6 25.8 26.0 26.2 26.4 26.6 26.8 27.0
3.0 30.1 30.4 30.7 30.9 31.2 31.4 31.7 32.0 32.3 32.5 32.8 33.1 33.3 33.6 33.9 34.2 34.4 34.7 35.0 35.3 35.5 35.8 36.1 36.4 36.7 36.9 37.2 37.5 37.8 38.1 38.4 38.6 38.9 39.2 39.5 39.8 40.1 40.4 40.7 41.0
4.0 40.4 40.8 41.2 41.5 41.9 42.2 42.6 43.0 43.3 43.7 44.1 44.4 44.8 45.2 45.5 45.9 46.3 46.6 47.0 47.4 47.8 48.1 48.5 48.9 49.3 49.7 50.0 50.4 50.8 51.2 51.6 52.0 52.4 52.8 53.1 53.5 53.9 54.3 54.7 55.1
5.0 50.8 51.3 51.7 52.2 52.6 53.1 53.5 54.0 54.5 54.9 55.4 55.9 56.3 56.8 57.3 57.7 58.2 58.7 59.1 59.6 60.1 60.6 61.0 61.5 62.0 62.5 63.0 63.5 63.9 64.4 64.9 65.4 65.9 66.4 66.9 67.4 67.9 68.4 68.9 69.4
6.0 61.3 61.8 62.4 62.9 63.5 64.0 64.6 65.1 65.7 66.2 66.8 67.4 67.9 68.5 69.0 69.6 70.2 70.8 71.3 71.9 72.5 73.1 73.6 74.2 74.8 75.4 76.0 76.6 77.2 77.8 78.3 78.9 79.5 80.1 80.7 81.3 81.9 82.6 83.2 83.8
7.0 71.8 72.4 73.0 73.7 74.3 75.0 75.6 76.3 76.9 77.6 78.2 78.9 79.6 80.2 80.9 81.6 82.2 82.9 83.6 84.3 84.9 85.6 86.3 87.0 87.7 88.4 89.1 89.7 90.4 91.1 91.8 92.5 93.2 93.9 94.7 95.4 96.1 96.8 97.5 98.2
8.0 82.3 83.0 83.7 84.5 85.2 86.0 86.7 87.5 88.2 89.0 89.7 90.5 91.3 92.0 92.8 93.6 94.3 95.1 95.9 96.7 97.4 98.2 99.0 99.8 101. 101. 102. 103. 104. 105. 105. 106. 107. 108. 109. 109. 110. 111. 112. 113.
Table A8-12 [continued]. Free-flow discharges in ft3/sec through 1- to 8-foot Parshall flumes. Discharges for 2- to 8-ft flumes computed from the formula Q =4.00Wh a1.522(W ^0.026). Discharges for 1-ft flume computed from the formula Q =3.95h a
1.55
Upper Head
h a, ft 2.20 2.21 2.22 2.23 2.24 2.25 2.26 2.27 2.28 2.29 2.30 2.31 2.32 2.33 2.34 2.35 2.36 2.37 2.38 2.39 2.40 2.41 2.42 2.43 2.44 2.45 2.46 2.47 2.48 2.49 2.50
1.0 13.4 13.5 13.6 13.7 13.8 13.9 14.0 14.1 14.2 14.3 14.4 14.5 14.6 14.7 14.8 14.9 14.9 15.0 15.1 15.2 15.3 15.4 15.5 15.6 15.7 15.8 15.9 16.0 16.1 16.2 16.3
2.0 27.1 27.3 27.5 27.7 27.9 28.1 28.3 28.5 28.7 28.9 29.1 29.3 29.5 29.7 29.9 30.1 30.3 30.5 30.7 30.9 31.1 31.3 31.5 31.7 31.9 32.1 32.3 32.5 32.7 32.9 33.1
3.0 41.3 41.5 41.8 42.1 42.4 42.7 43.0 43.3 43.6 43.9 44.2 44.5 44.8 45.1 45.4 45.7 46.0 46.4 46.7 47.0 47.3 47.6 47.9 48.2 48.5 48.8 49.1 49.5 49.8 50.1 50.4
4.0 55.5 55.9 56.3 56.7 57.1 57.5 57.9 58.3 58.7 59.1 59.5 60.0 60.4 60.8 61.2 61.6 62.0 62.4 62.9 63.3 63.7 64.1 64.5 64.9 65.4 65.8 66.2 66.6 67.1 67.5 67.9
5.0 69.9 70.4 70.9 71.4 71.9 72.4 72.9 73.5 74.0 74.5 75.0 75.5 76.0 76.6 77.1 77.6 78.1 78.7 79.2 79.7 80.2 80.8 81.3 81.8 82.4 82.9 83.5 84.0 84.5 85.1 85.6
6.0 84.4 85.0 85.6 86.2 86.8 87.5 88.1 88.7 89.3 89.9 90.6 91.2 91.8 92.5 93.1 93.7 94.4 95.0 95.7 96.3 96.9 97.6 98.2 98.9 99.5 100. 101. 101. 102. 103. 103.
7.0 98.9 99.7 100. 101. 102. 103. 103. 104. 105. 105. 106. 107. 108. 108. 109. 110. 111. 111. 112. 113. 114. 114. 115. 116. 117. 118. 118. 119. 120. 121. 121.
8.0 114. 114. 115. 116. 117. 118. 119. 119. 120. 121. 122. 123. 124. 125. 125. 126. 127. 128. 129. 130. 131. 131. 132. 133. 134. 135. 136. 137. 138. 139. 139.
Table A8-13. Free-flow discharge through 10-ft Parshall measuring flume in ft3/sec. Computed from the formula Q =39.38h a1.6.
Upper Head h a, ft 0.10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 2.60 2.70 2.80 2.90 3.00 3.10 3.20 3.30 3.40 3.50 3.60 3.70 3.80 3.90 4.00 4.10 4.20 4.30 4.40 4.50 4.60 4.70 4.80 4.90 5.00 Hundredths 0.04 0.05 1.69 4.01 7.01 10.6 14.7 19.3 24.3 29.8 35.7 41.9 48.6 55.6 62.9 70.6 78.6 86.9 95.5 104. 114. 123. 133. 143. 153. 164. 175. 186. 198. 209. 221. 233. 246. 258. 271. 284. 298. 311. 325. 339. 353. 368. 382. 397. 412. 428. 443. 459. 475. 491. 507. 524. 1.89 4.29 7.34 11.0 15.1 19.8 24.9 30.4 36.3 42.6 49.2 56.3 63.7 71.4 79.4 87.8 96.4 105. 115. 124. 134. 144. 155. 165. 176. 187. 199. 210. 222. 235. 247. 260. 272. 286. 299. 313. 326. 340. 355. 369. 384. 399. 414. 429. 445. 460. 476. 493. 509. 525.
0.00 0.99 3.00 5.74 9.09 13.0 17.4 22.3 27.6 33.3 39.4 45.9 52.7 59.9 67.5 75.3 83.5 92.0 101. 110. 119. 129. 139. 149. 160. 171. 182. 193. 205. 216. 228. 241. 253. 266. 279. 292. 306. 319. 333. 348. 362. 376. 391. 406. 422. 437. 453. 468. 484. 501. 517.
0.01 1.15 3.24 6.05 9.46 13.4 17.9 22.8 28.1 33.9 40.0 46.5 53.4 60.7 68.2 76.1 84.4 92.9 102. 111. 120. 130. 140. 150. 161. 172. 183. 194. 206. 218. 230. 242. 254. 267. 280. 294. 307. 321. 335. 349. 363. 378. 393. 408. 423. 438. 454. 470. 486. 502. 519.
0.02 1.32 3.49 6.36 9.83 13.8 18.3 23.3 28.7 34.5 40.6 47.2 54.1 61.4 69.0 77.0 85.2 93.8 103. 112. 121. 131. 141. 151. 162. 173. 184. 195. 207. 219. 231. 243. 256. 269. 282. 295. 308. 322. 336. 350. 365. 379. 394. 409. 425. 440. 456. 472. 488. 504. 520.
0.03 1.51 3.75 6.68 10.2 14.3 18.8 23.8 29.2 35.1 41.3 47.9 54.8 62.1 69.8 77.8 86.1 94.7 104. 113. 122. 132. 142. 152. 163. 174. 185. 196. 208. 220. 232. 244. 257. 270. 283. 296. 310. 324. 338. 352. 366. 381. 396. 411. 426. 442. 457. 473. 489. 506. 522.
0.06 2.10 4.56 7.68 11.4 15.6 20.3 25.4 30.9 36.9 43.2 49.9 57.0 64.4 72.2 80.2 88.6 97.3 106. 116. 125. 135. 145. 156. 166. 177. 188. 200. 212. 224. 236. 248. 261. 274. 287. 300. 314. 328. 342. 356. 371. 385. 400. 415. 431. 446. 462. 478. 494. 511. 527.
0.07 2.31 4.85 8.02 11.8 16.0 20.7 25.9 31.5 37.5 43.9 50.6 57.7 65.2 72.9 81.0 89.5 98.2 107. 117. 126. 136. 146. 157. 167. 178. 190. 201. 213. 225. 237. 249. 262. 275. 288. 302. 315. 329. 343. 358. 372. 387. 402. 417. 432. 448. 464. 480. 496. 512. 529.
0.08 2.53 5.14 8.37 12.2 16.5 21.2 26.5 32.1 38.1 44.5 51.3 58.5 65.9 73.7 81.9 90.3 99.1 108. 117. 127. 137. 147. 158. 168. 179. 191. 202. 214. 226. 238. 251. 263. 276. 290. 303. 317. 331. 345. 359. 374. 388. 403. 418. 434. 449. 465. 481. 497. 514. 530.
0.09 2.76 5.43 8.73 12.6 16.9 21.7 27.0 32.7 38.8 45.2 52.0 59.2 66.7 74.5 82.7 91.2 100. 109. 118. 128. 138. 148. 159. 170. 181. 192. 203. 215. 227. 239. 252. 265. 278. 291. 304. 318. 332. 346. 360. 375. 390. 405. 420. 435. 451. 467. 483. 499. 516. 532.
Table A8-14. Free-flow discharge through 12-ft Parshall measuring flume in ft3/sec. Computed from the formula Q =46.75h a1.6.
Upper Head h a, ft 0.10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 2.60 2.70 2.80 2.90 3.00 3.10 3.20 3.30 3.40 3.50 3.60 3.70 3.80 3.90 4.00 4.10 4.20 4.30 4.40 4.50 4.60 4.70 4.80 4.90 5.00 Hundredths 0.04 0.05 2.01 4.77 8.32 12.6 17.4 22.9 28.9 35.4 42.3 49.8 57.7 66.0 74.7 83.8 93.3 103. 113. 124. 135. 146. 158. 170. 182. 195. 208. 221. 235. 248. 263. 277. 292. 307. 322. 338. 353. 369. 386. 402. 419. 437. 454. 472. 490. 508. 526. 545. 564. 583. 602. 622. 2.25 5.09 8.72 13.0 18.0 23.5 29.5 36.0 43.1 50.5 58.5 66.8 75.6 84.7 94.3 104. 114. 125. 136. 147. 159. 171. 183. 196. 209. 222. 236. 250. 264. 278. 293. 308. 323. 339. 355. 371. 387. 404. 421. 438. 456. 473. 491. 510. 528. 547. 566. 585. 604. 624.
0.00 1.17 3.56 6.81 10.8 15.4 20.6 26.4 32.7 39.5 46.8 54.5 62.6 71.1 80.1 89.4 99.2 109. 120. 131. 142. 153. 165. 177. 190. 203. 216. 229. 243. 257. 271. 286. 301. 316. 331. 347. 363. 379. 396. 413. 430. 447. 464. 482. 500. 519. 537. 556. 575. 594. 614.
0.01 1.37 3.85 7.18 11.2 15.9 21.2 27.0 33.4 40.2 47.5 55.2 63.4 72.0 81.0 90.4 100. 110. 121. 132. 143. 154. 166. 178. 191. 204. 217. 230. 244. 258. 273. 287. 302. 317. 333. 349. 365. 381. 397. 414. 431. 449. 466. 484. 502. 521. 539. 558. 577. 596. 616.
0.02 1.57 4.15 7.55 11.7 16.4 21.8 27.6 34.0 40.9 48.3 56.0 64.3 72.9 81.9 91.4 101. 111. 122. 133. 144. 156. 167. 180. 192. 205. 218. 232. 246. 260. 274. 289. 304. 319. 334. 350. 366. 383. 399. 416. 433. 450. 468. 486. 504. 522. 541. 560. 579. 598. 618.
0.03 1.79 4.45 7.93 12.1 16.9 22.3 28.3 34.7 41.6 49.0 56.8 65.1 73.8 82.9 92.3 102. 112. 123. 134. 145. 157. 169. 181. 194. 206. 220. 233. 247. 261. 275. 290. 305. 320. 336. 352. 368. 384. 401. 418. 435. 452. 470. 488. 506. 524. 543. 562. 581. 600. 620.
0.06 2.49 5.42 9.12 13.5 18.5 24.0 30.1 36.7 43.8 51.3 59.3 67.7 76.5 85.7 95.2 105. 116. 126. 137. 149. 160. 172. 185. 197. 210. 224. 237. 251. 265. 280. 295. 310. 325. 341. 357. 373. 389. 406. 423. 440. 457. 475. 493. 511. 530. 549. 567. 587. 606. 626.
0.07 2.74 5.75 9.53 14.0 19.0 24.6 30.8 37.4 44.5 52.1 60.1 68.5 77.4 86.6 96.2 106. 117. 127. 138. 150. 161. 174. 186. 199. 212. 225. 239. 253. 267. 281. 296. 311. 327. 342. 358. 374. 391. 407. 424. 442. 459. 477. 495. 513. 532. 550. 569. 589. 608. 628.
0.08 3.01 6.10 9.94 14.4 19.6 25.2 31.4 38.1 45.3 52.9 60.9 69.4 78.3 87.5 97.2 107. 118. 128. 139. 151. 163. 175. 187. 200. 213. 226. 240. 254. 268. 283. 298. 313. 328. 344. 360. 376. 392. 409. 426. 443. 461. 479. 497. 515. 534. 552. 571. 591. 610. 630.
0.09 3.28 6.45 10.4 14.9 20.1 25.8 32.1 38.8 46.0 53.7 61.8 70.3 79.2 88.5 98.2 108. 119. 129. 141. 152. 164. 176. 188. 201. 214. 228. 241. 255. 270. 284. 299. 314. 330. 345. 361. 378. 394. 411. 428. 445. 463. 481. 499. 517. 535. 554. 573. 592. 612. 632.
Table A8-15. Free-flow discharge through 15-ft Parshall measuring flume in ft3/sec. Computed from the formula Q =57.81h a1.6.
Upper Head h a, ft 0.30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 2.60 2.70 2.80 2.90 3.00 3.10 3.20 3.30 3.40 3.50 3.60 3.70 3.80 3.90 4.00 4.10 4.20 4.30 4.40 4.50 4.60 4.70 4.80 4.90 5.00 5.10 5.20 5.30 5.40 5.50 5.60 5.70 5.80 5.90 6.00 Hundredths 0.04 0.05 10.3 15.5 21.6 28.3 35.7 43.7 52.4 61.6 71.3 81.6 92.3 104. 115. 128. 140. 153. 167. 181. 195. 210. 225. 241. 257. 273. 290. 307. 325. 342. 361. 379. 398. 417. 437. 457. 477. 498. 519. 540. 561. 583. 605. 628. 651. 674. 697. 721. 745. 769. 793. 818. 843. 869. 895. 921. 947. 973. 1000. 1027. 10.8 16.1 22.2 29.0 36.5 44.6 53.3 62.5 72.3 82.6 93.4 105. 117. 129. 142. 155. 168. 182. 197. 212. 227. 242. 259. 275. 292. 309. 326. 344. 362. 381. 400. 419. 439. 459. 479. 500. 521. 542. 563. 585. 608. 630. 653. 676. 699. 723. 747. 771. 796. 821. 846. 871. 897. 923. 949. 976. 1003. 1030.
0.00 8.42 13.3 19.1 25.5 32.7 40.5 48.8 57.8 67.3 77.4 88.0 99.0 111. 123. 135. 148. 161. 175. 189. 204. 219. 235. 250. 267. 283. 300. 318. 335. 353. 372. 391. 410. 429. 449. 469. 489. 510. 531. 553. 574. 596. 619. 641. 664. 688. 711. 735. 759. 784. 808. 833. 859. 884. 910. 936. 963. 989. 1016.
0.01 8.88 13.9 19.7 26.2 33.4 41.3 49.7 58.7 68.3 78.4 89.1 100. 112. 124. 136. 149. 163. 177. 191. 206. 221. 236. 252. 268. 285. 302. 319. 337. 355. 374. 392. 412. 431. 451. 471. 491. 512. 533. 555. 577. 599. 621. 644. 667. 690. 714. 737. 762. 786. 811. 836. 861. 887. 913. 939. 965. 992. 1019.
0.02 9.34 14.4 20.3 26.9 34.2 42.1 50.6 59.7 69.3 79.5 90.1 101. 113. 125. 138. 151. 164. 178. 192. 207. 222. 238. 254. 270. 287. 304. 321. 339. 357. 375. 394. 413. 433. 453. 473. 494. 514. 536. 557. 579. 601. 623. 646. 669. 692. 716. 740. 764. 789. 813. 838. 864. 889. 915. 942. 968. 995. 1022.
0.03 9.81 15.0 20.9 27.6 34.9 42.9 51.5 60.6 70.3 80.5 91.2 102. 114. 126. 139. 152. 166. 179. 194. 209. 224. 239. 255. 272. 288. 305. 323. 341. 359. 377. 396. 415. 435. 455. 475. 496. 516. 538. 559. 581. 603. 626. 648. 671. 695. 718. 742. 766. 791. 816. 841. 866. 892. 918. 944. 971. 997. 1024.
0.06 11.3 16.7 22.9 29.7 37.3 45.4 54.2 63.5 73.3 83.7 94.6 106. 118. 130. 143. 156. 170. 184. 198. 213. 228. 244. 260. 277. 293. 311. 328. 346. 364. 383. 402. 421. 441. 461. 481. 502. 523. 544. 566. 588. 610. 632. 655. 678. 702. 725. 750. 774. 798. 823. 849. 874. 900. 926. 952. 979. 1006. 1033.
0.07 11.8 17.3 23.5 30.5 38.1 46.3 55.1 64.4 74.3 84.7 95.7 107. 119. 131. 144. 157. 171. 185. 200. 215. 230. 246. 262. 278. 295. 312. 330. 348. 366. 385. 404. 423. 443. 463. 483. 504. 525. 546. 568. 590. 612. 635. 657. 681. 704. 728. 752. 776. 801. 826. 851. 877. 902. 928. 955. 981. 1008. 1035.
0.08 12.3 17.9 24.2 31.2 38.8 47.1 56.0 65.4 75.3 85.8 96.8 108. 120. 133. 145. 159. 172. 187. 201. 216. 231. 247. 263. 280. 297. 314. 332. 350. 368. 387. 406. 425. 445. 465. 485. 506. 527. 548. 570. 592. 614. 637. 660. 683. 706. 730. 754. 779. 803. 828. 854. 879. 905. 931. 957. 984. 1011. 1038.
0.09 12.8 18.5 24.9 31.9 39.6 48.0 56.9 66.4 76.4 86.9 97.9 109. 121. 134. 147. 160. 174. 188. 203. 218. 233. 249. 265. 282. 299. 316. 333. 352. 370. 389. 408. 427. 447. 467. 487. 508. 529. 551. 572. 594. 617. 639. 662. 685. 709. 733. 757. 781. 806. 831. 856. 882. 908. 934. 960. 987. 1014. 1041.
Table A8-16. Free-flow discharge through 20-ft Parshall measuring flume in ft3/sec. Computed from the formula Q =76.25h a1.6.
Upper Head h a, ft 0.30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 2.60 2.70 2.80 2.90 3.00 3.10 3.20 3.30 3.40 3.50 3.60 3.70 3.80 3.90 4.00 4.10 4.20 4.30 4.40 4.50 4.60 4.70 4.80 4.90 5.00 5.10 5.20 5.30 5.40 5.50 5.60 5.70 5.80 5.90 6.00 Hundredths 0.04 0.05 13.6 20.5 28.4 37.3 47.1 57.7 69.1 81.2 94.0 108. 122. 137. 152. 168. 185. 202. 220. 239. 258. 277. 297. 318. 339. 360. 383. 405. 428. 452. 476. 500. 525. 550. 576. 603. 629. 656. 684. 712. 740. 769. 798. 828. 858. 889. 919. 951. 982. 1014. 1047. 1079. 1113. 1146. 1180. 1214. 1249. 1284. 1319. 1355. 14.2 21.3 29.3 38.3 48.1 58.8 70.2 82.4 95.4 109. 123. 138. 154. 170. 187. 204. 222. 240. 260. 279. 299. 320. 341. 363. 385. 407. 430. 454. 478. 503. 528. 553. 579. 605. 632. 659. 687. 715. 743. 772. 801. 831. 861. 892. 922. 954. 985. 1017. 1050. 1083. 1116. 1149. 1183. 1218. 1252. 1287. 1323. 1358.
0.00 11.1 17.6 25.2 33.7 43.1 53.4 64.4 76.3 88.8 102. 116. 131. 146. 162. 178. 195. 213. 231. 250. 269. 289. 309. 330. 352. 374. 396. 419. 442. 466. 490. 515. 540. 566. 592. 619. 645. 673. 701. 729. 758. 787. 816. 846. 876. 907. 938. 970. 1001. 1034. 1066. 1099. 1133. 1166. 1200. 1235. 1270. 1305. 1341.
0.01 11.7 18.3 26.0 34.6 44.1 54.4 65.6 77.5 90.1 103. 117. 132. 147. 163. 180. 197. 215. 233. 252. 271. 291. 312. 332. 354. 376. 398. 421. 445. 468. 493. 518. 543. 569. 595. 621. 648. 676. 704. 732. 760. 790. 819. 849. 879. 910. 941. 973. 1005. 1037. 1069. 1103. 1136. 1170. 1204. 1238. 1273. 1309. 1344.
0.02 12.3 19.0 26.8 35.5 45.1 55.5 66.7 78.7 91.4 105. 119. 134. 149. 165. 182. 199. 217. 235. 254. 273. 293. 314. 335. 356. 378. 401. 423. 447. 471. 495. 520. 545. 571. 597. 624. 651. 678. 706. 735. 763. 793. 822. 852. 882. 913. 944. 976. 1008. 1040. 1073. 1106. 1139. 1173. 1207. 1242. 1277. 1312. 1348.
0.03 12.9 19.8 27.6 36.4 46.1 56.6 67.9 79.9 92.7 106. 120. 135. 151. 167. 183. 201. 218. 237. 256. 275. 295. 316. 337. 358. 380. 403. 426. 449. 473. 498. 523. 548. 574. 600. 627. 654. 681. 709. 737. 766. 795. 825. 855. 885. 916. 947. 979. 1011. 1043. 1076. 1109. 1143. 1177. 1211. 1245. 1280. 1316. 1351.
0.06 14.9 22.0 30.2 39.2 49.2 59.9 71.4 83.7 96.7 110. 125. 140. 155. 172. 188. 206. 224. 242. 261. 281. 301. 322. 343. 365. 387. 410. 433. 456. 481. 505. 530. 556. 582. 608. 635. 662. 690. 718. 746. 775. 804. 834. 864. 895. 926. 957. 989. 1021. 1053. 1086. 1119. 1153. 1187. 1221. 1256. 1291. 1326. 1362.
0.07 15.5 22.8 31.0 40.2 50.2 61.0 72.6 85.0 98.0 112. 126. 141. 157. 173. 190. 208. 226. 244. 263. 283. 303. 324. 345. 367. 389. 412. 435. 459. 483. 508. 533. 558. 584. 611. 637. 665. 692. 720. 749. 778. 807. 837. 867. 898. 929. 960. 992. 1024. 1056. 1089. 1123. 1156. 1190. 1225. 1259. 1294. 1330. 1366.
0.08 16.2 23.6 31.9 41.1 51.2 62.1 73.8 86.2 99.4 113. 128. 143. 159. 175. 192. 209. 227. 246. 265. 285. 305. 326. 347. 369. 391. 414. 438. 461. 485. 510. 535. 561. 587. 613. 640. 667. 695. 723. 752. 781. 810. 840. 870. 901. 932. 963. 995. 1027. 1060. 1093. 1126. 1160. 1194. 1228. 1263. 1298. 1333. 1369.
0.09 16.9 24.4 32.8 42.1 52.3 63.3 75.0 87.5 101. 115. 129. 144. 160. 177. 194. 211. 229. 248. 267. 287. 307. 328. 350. 371. 394. 417. 440. 464. 488. 513. 538. 563. 589. 616. 643. 670. 698. 726. 755. 784. 813. 843. 873. 904. 935. 966. 998. 1030. 1063. 1096. 1129. 1163. 1197. 1231. 1266. 1301. 1337. 1373.
Table A8-17. Free-flow discharge through 25-ft Parshall measuring flume in ft3/sec. Computed from the formula Q =94.69h a1.6.
Upper Head h a, ft 0.30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 2.60 2.70 2.80 2.90 3.00 3.10 3.20 3.30 3.40 3.50 3.60 3.70 3.80 3.90 4.00 4.10 4.20 4.30 4.40 4.50 4.60 4.70 4.80 4.90 5.00 5.10 5.20 5.30 5.40 5.50 5.60 5.70 5.80 5.90 6.00 Hundredths 0.04 0.05 16.9 25.5 35.3 46.4 58.5 71.6 85.8 101. 117. 134. 151. 170. 189. 209. 230. 251. 273. 296. 320. 344. 369. 395. 421. 448. 475. 503. 532. 561. 591. 621. 652. 684. 716. 748. 781. 815. 849. 884. 919. 955. 991. 1028. 1066. 1103. 1142. 1180. 1220. 1259. 1300. 1340. 1382. 1423. 1465. 1508. 1551. 1594. 1638. 1683. 17.7 26.4 36.4 47.5 59.8 73.0 87.2 102. 118. 135. 153. 172. 191. 211. 232. 253. 276. 299. 322. 347. 372. 397. 423. 450. 478. 506. 535. 564. 594. 624. 655. 687. 719. 752. 785. 819. 853. 888. 923. 959. 995. 1032. 1069. 1107. 1146. 1184. 1224. 1263. 1304. 1344. 1386. 1427. 1470. 1512. 1555. 1599. 1643. 1687.
0.00 13.8 21.9 31.2 41.8 53.5 66.3 80.0 94.7 110. 127. 144. 162. 181. 201. 221. 243. 264. 287. 310. 334. 359. 384. 410. 437. 464. 492. 520. 549. 579. 609. 640. 671. 703. 735. 768. 802. 836. 870. 905. 941. 977. 1014. 1051. 1088. 1126. 1165. 1204. 1244. 1284. 1324. 1365. 1406. 1448. 1491. 1534. 1577. 1621. 1665.
0.01 14.5 22.7 32.2 42.9 54.7 67.6 81.4 96.2 112. 128. 146. 164. 183. 203. 223. 245. 267. 289. 313. 337. 361. 387. 413. 439. 467. 495. 523. 552. 582. 612. 643. 674. 706. 738. 771. 805. 839. 874. 909. 944. 981. 1017. 1054. 1092. 1130. 1169. 1208. 1248. 1288. 1328. 1369. 1411. 1453. 1495. 1538. 1581. 1625. 1669.
0.02 15.3 23.6 33.3 44.1 56.0 68.9 82.9 97.7 114. 130. 148. 166. 185. 205. 226. 247. 269. 292. 315. 339. 364. 389. 415. 442. 469. 497. 526. 555. 585. 615. 646. 677. 709. 742. 775. 808. 842. 877. 912. 948. 984. 1021. 1058. 1096. 1134. 1173. 1212. 1251. 1292. 1332. 1373. 1415. 1457. 1499. 1542. 1586. 1629. 1674.
0.03 16.1 24.5 34.3 45.2 57.2 70.3 84.3 99.3 115. 132. 149. 168. 187. 207. 228. 249. 271. 294. 317. 342. 366. 392. 418. 445. 472. 500. 529. 558. 588. 618. 649. 680. 712. 745. 778. 812. 846. 881. 916. 952. 988. 1025. 1062. 1100. 1138. 1177. 1216. 1255. 1296. 1336. 1377. 1419. 1461. 1504. 1547. 1590. 1634. 1678.
0.06 18.5 27.3 37.4 48.7 61.0 74.4 88.7 104. 120. 137. 155. 173. 193. 213. 234. 256. 278. 301. 325. 349. 374. 400. 426. 453. 481. 509. 537. 567. 597. 627. 658. 690. 722. 755. 788. 822. 856. 891. 927. 962. 999. 1036. 1073. 1111. 1149. 1188. 1228. 1267. 1308. 1349. 1390. 1432. 1474. 1516. 1559. 1603. 1647. 1691.
0.07 19.3 28.3 38.5 49.9 62.3 75.8 90.2 106. 122. 139. 157. 175. 195. 215. 236. 258. 280. 303. 327. 352. 377. 402. 429. 456. 483. 512. 540. 570. 600. 630. 661. 693. 725. 758. 791. 825. 860. 895. 930. 966. 1002. 1039. 1077. 1115. 1153. 1192. 1232. 1272. 1312. 1353. 1394. 1436. 1478. 1521. 1564. 1607. 1651. 1696.
0.08 20.1 29.3 39.6 51.1 63.6 77.2 91.7 107. 123. 141. 159. 177. 197. 217. 238. 260. 282. 306. 329. 354. 379. 405. 431. 458. 486. 514. 543. 573. 603. 633. 665. 696. 729. 761. 795. 829. 863. 898. 934. 970. 1006. 1043. 1081. 1119. 1157. 1196. 1236. 1276. 1316. 1357. 1398. 1440. 1482. 1525. 1568. 1612. 1656. 1700.
0.09 21.0 30.2 40.7 52.3 64.9 78.6 93.2 109. 125. 142. 160. 179. 199. 219. 240. 262. 285. 308. 332. 356. 382. 408. 434. 461. 489. 517. 546. 576. 606. 637. 668. 700. 732. 765. 798. 832. 867. 902. 937. 973. 1010. 1047. 1084. 1122. 1161. 1200. 1240. 1280. 1320. 1361. 1402. 1444. 1486. 1529. 1572. 1616. 1660. 1705.
Table A8-18. Free-flow discharge through 30-ft Parshall measuring flume in ft3/sec. Computed from the formula Q =113.13h a1.6.
Upper Head h a, ft 0.30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 2.60 2.70 2.80 2.90 3.00 3.10 3.20 3.30 3.40 3.50 3.60 3.70 3.80 3.90 4.00 4.10 4.20 4.30 4.40 4.50 4.60 4.70 4.80 4.90 5.00 5.10 5.20 5.30 5.40 5.50 5.60 5.70 5.80 5.90 6.00 Hundredths 0.04 0.05 20.1 30.4 42.2 55.4 69.9 85.6 102. 120. 140. 160. 181. 203. 226. 250. 274. 300. 327. 354. 382. 411. 441. 471. 503. 535. 568. 601. 635. 670. 706. 742. 779. 817. 855. 894. 934. 974. 1015. 1056. 1098. 1141. 1185. 1229. 1273. 1318. 1364. 1410. 1457. 1505. 1553. 1601. 1651. 1700. 1751. 1801. 1853. 1905. 1957. 2010. 21.1 31.5 43.5 56.8 71.4 87.2 104. 122. 141. 162. 183. 205. 228. 252. 277. 303. 329. 357. 385. 414. 444. 475. 506. 538. 571. 604. 639. 674. 709. 746. 783. 821. 859. 898. 938. 978. 1019. 1060. 1103. 1146. 1189. 1233. 1278. 1323. 1369. 1415. 1462. 1510. 1558. 1606. 1656. 1705. 1756. 1807. 1858. 1910. 1962. 2016.
0.00 16.5 26.1 37.3 50.0 63.9 79.2 95.6 113. 132. 151. 172. 194. 216. 240. 264. 290. 316. 343. 371. 399. 429. 459. 490. 522. 554. 588. 621. 656. 691. 727. 764. 802. 840. 878. 918. 958. 998. 1040. 1082. 1124. 1167. 1211. 1255. 1300. 1346. 1392. 1438. 1486. 1534. 1582. 1631. 1680. 1730. 1781. 1832. 1884. 1936. 1989.
0.01 17.4 27.2 38.5 51.3 65.4 80.8 97.3 115. 134. 153. 174. 196. 219. 242. 267. 292. 319. 346. 374. 402. 432. 462. 493. 525. 558. 591. 625. 660. 695. 731. 768. 805. 843. 882. 922. 962. 1002. 1044. 1086. 1128. 1171. 1215. 1260. 1305. 1350. 1396. 1443. 1490. 1538. 1587. 1636. 1685. 1735. 1786. 1837. 1889. 1941. 1994.
0.02 18.3 28.2 39.7 52.7 66.9 82.4 99.0 117. 136. 156. 176. 198. 221. 245. 269. 295. 321. 348. 376. 405. 435. 465. 496. 528. 561. 594. 628. 663. 699. 735. 772. 809. 847. 886. 926. 966. 1007. 1048. 1090. 1133. 1176. 1220. 1264. 1309. 1355. 1401. 1448. 1495. 1543. 1592. 1641. 1690. 1741. 1791. 1843. 1894. 1947. 2000.
0.03 19.2 29.3 41.0 54.0 68.4 84.0 101. 119. 138. 158. 179. 201. 223. 247. 272. 298. 324. 351. 379. 408. 438. 468. 500. 532. 564. 598. 632. 667. 702. 738. 775. 813. 851. 890. 930. 970. 1011. 1052. 1094. 1137. 1180. 1224. 1269. 1314. 1359. 1406. 1453. 1500. 1548. 1597. 1646. 1695. 1746. 1796. 1848. 1900. 1952. 2005.
0.06 22.1 32.7 44.7 58.2 72.9 88.9 106. 124. 143. 164. 185. 207. 230. 255. 280. 305. 332. 360. 388. 417. 447. 478. 509. 541. 574. 608. 642. 677. 713. 749. 787. 824. 863. 902. 942. 982. 1023. 1065. 1107. 1150. 1193. 1237. 1282. 1327. 1373. 1420. 1467. 1514. 1562. 1611. 1661. 1710. 1761. 1812. 1863. 1915. 1968. 2021.
0.07 23.1 33.8 46.0 59.6 74.5 90.5 108. 126. 145. 166. 187. 210. 233. 257. 282. 308. 335. 362. 391. 420. 450. 481. 512. 544. 577. 611. 646. 681. 717. 753. 790. 828. 867. 906. 946. 986. 1027. 1069. 1111. 1154. 1198. 1242. 1287. 1332. 1378. 1424. 1471. 1519. 1567. 1616. 1665. 1715. 1766. 1817. 1868. 1920. 1973. 2026.
0.08 24.1 35.0 47.3 61.0 76.0 92.2 110. 128. 147. 168. 189. 212. 235. 259. 285. 311. 337. 365. 394. 423. 453. 484. 515. 548. 581. 615. 649. 684. 720. 757. 794. 832. 871. 910. 950. 990. 1031. 1073. 1115. 1158. 1202. 1246. 1291. 1337. 1382. 1429. 1476. 1524. 1572. 1621. 1670. 1720. 1771. 1822. 1874. 1926. 1978. 2032.
0.09 25.1 36.1 48.6 62.5 77.6 93.9 111. 130. 149. 170. 192. 214. 238. 262. 287. 313. 340. 368. 397. 426. 456. 487. 519. 551. 584. 618. 653. 688. 724. 760. 798. 836. 874. 914. 954. 994. 1035. 1077. 1120. 1163. 1206. 1251. 1296. 1341. 1387. 1434. 1481. 1529. 1577. 1626. 1675. 1725. 1776. 1827. 1879. 1931. 1984. 2037.
Table A8-19. Free-flow discharge through 40-ft Parshall measuring flume in ft3/sec. Computed from the formula Q =150.00h a1.6.
Upper Head h a, ft 0.30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 2.60 2.70 2.80 2.90 3.00 3.10 3.20 3.30 3.40 3.50 3.60 3.70 3.80 3.90 4.00 4.10 4.20 4.30 4.40 4.50 4.60 4.70 4.80 4.90 5.00 5.10 5.20 5.30 5.40 5.50 5.60 5.70 5.80 5.90 6.00 Hundredths 0.04 0.05 26.7 40.3 56.0 73.4 92.7 113. 136. 160. 185. 212. 240. 269. 299. 331. 364. 398. 433. 469. 507. 545. 585. 625. 667. 709. 752. 797. 842. 889. 936. 984. 1033. 1083. 1134. 1185. 1238. 1291. 1346. 1401. 1456. 1513. 1571. 1629. 1688. 1748. 1809. 1870. 1932. 1995. 2059. 2123. 2189. 2254. 2321. 2389. 2457. 2526. 2595. 2665. 28.0 41.8 57.6 75.3 94.7 116. 138. 162. 188. 214. 242. 272. 302. 334. 367. 401. 437. 473. 510. 549. 589. 629. 671. 713. 757. 801. 847. 893. 941. 989. 1038. 1088. 1139. 1191. 1243. 1297. 1351. 1406. 1462. 1519. 1576. 1635. 1694. 1754. 1815. 1876. 1938. 2002. 2065. 2130. 2195. 2261. 2328. 2395. 2464. 2532. 2602. 2672.
0.00 21.9 34.6 49.5 66.2 84.8 105. 127. 150. 175. 201. 228. 257. 287. 318. 351. 384. 419. 455. 492. 530. 569. 609. 650. 692. 735. 779. 824. 870. 917. 965. 1013. 1063. 1113. 1165. 1217. 1270. 1324. 1378. 1434. 1490. 1548. 1606. 1664. 1724. 1784. 1845. 1907. 1970. 2033. 2097. 2162. 2228. 2294. 2362. 2429. 2498. 2567. 2637.
0.01 23.0 36.0 51.1 68.0 86.7 107. 129. 152. 177. 203. 231. 260. 290. 321. 354. 388. 422. 458. 495. 533. 573. 613. 654. 696. 739. 783. 829. 875. 922. 969. 1018. 1068. 1118. 1170. 1222. 1275. 1329. 1384. 1440. 1496. 1553. 1611. 1670. 1730. 1790. 1851. 1913. 1976. 2040. 2104. 2169. 2235. 2301. 2368. 2436. 2505. 2574. 2644.
0.02 24.2 37.4 52.7 69.8 88.7 109. 131. 155. 180. 206. 234. 263. 293. 325. 357. 391. 426. 462. 499. 537. 577. 617. 658. 700. 744. 788. 833. 879. 926. 974. 1023. 1073. 1123. 1175. 1227. 1281. 1335. 1389. 1445. 1502. 1559. 1617. 1676. 1736. 1796. 1858. 1920. 1983. 2046. 2110. 2175. 2241. 2308. 2375. 2443. 2512. 2581. 2651.
0.03 25.5 38.9 54.3 71.6 90.7 111. 134. 157. 182. 209. 237. 266. 296. 328. 361. 394. 430. 466. 503. 541. 581. 621. 662. 705. 748. 792. 838. 884. 931. 979. 1028. 1078. 1129. 1180. 1233. 1286. 1340. 1395. 1451. 1507. 1565. 1623. 1682. 1742. 1802. 1864. 1926. 1989. 2052. 2117. 2182. 2248. 2314. 2382. 2450. 2519. 2588. 2658.
0.06 29.3 43.3 59.3 77.2 96.7 118. 141. 165. 190. 217. 245. 275. 306. 337. 371. 405. 440. 477. 514. 553. 593. 633. 675. 718. 761. 806. 851. 898. 945. 994. 1043. 1093. 1144. 1196. 1249. 1302. 1356. 1412. 1468. 1525. 1582. 1641. 1700. 1760. 1821. 1882. 1945. 2008. 2072. 2136. 2202. 2268. 2335. 2402. 2470. 2539. 2609. 2679.
0.07 30.6 44.8 61.0 79.0 98.7 120. 143. 167. 193. 220. 248. 278. 309. 341. 374. 408. 444. 480. 518. 557. 597. 637. 679. 722. 766. 810. 856. 903. 950. 999. 1048. 1098. 1149. 1201. 1254. 1307. 1362. 1417. 1473. 1530. 1588. 1647. 1706. 1766. 1827. 1889. 1951. 2014. 2078. 2143. 2208. 2274. 2341. 2409. 2477. 2546. 2616. 2687.
0.08 31.9 46.4 62.7 80.9 101. 122. 145. 170. 195. 223. 251. 281. 312. 344. 377. 412. 447. 484. 522. 561. 601. 642. 683. 726. 770. 815. 861. 907. 955. 1003. 1053. 1103. 1154. 1206. 1259. 1313. 1367. 1423. 1479. 1536. 1594. 1652. 1712. 1772. 1833. 1895. 1957. 2021. 2085. 2149. 2215. 2281. 2348. 2416. 2484. 2553. 2623. 2694.
0.09 33.3 47.9 64.5 82.8 103. 124. 148. 172. 198. 225. 254. 284. 315. 347. 381. 415. 451. 488. 526. 565. 605. 646. 688. 731. 775. 819. 865. 912. 960. 1008. 1058. 1108. 1159. 1212. 1264. 1318. 1373. 1428. 1485. 1542. 1600. 1658. 1718. 1778. 1839. 1901. 1964. 2027. 2091. 2156. 2221. 2288. 2355. 2423. 2491. 2560. 2630. 2701.
Table A8-20. Free-flow discharge through 50-ft Parshall measuring flume in ft3/sec. Computed from the formula Q =186.88h a1.6.
Upper Head h a, ft 0.30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.20 1.30 1.40 1.50 1.60 1.70 1.80 1.90 2.00 2.10 2.20 2.30 2.40 2.50 2.60 2.70 2.80 2.90 3.00 3.10 3.20 3.30 3.40 3.50 3.60 3.70 3.80 3.90 4.00 4.10 4.20 4.30 4.40 4.50 4.60 4.70 4.80 4.90 5.00 5.10 5.20 5.30 5.40 5.50 5.60 5.70 5.80 5.90 6.00 Hundredths 0.04 0.05 33.3 50.2 69.7 91.5 115. 141. 169. 199. 230. 264. 298. 335. 373. 412. 453. 496. 540. 585. 631. 679. 728. 779. 830. 883. 937. 993. 1049. 1107. 1166. 1226. 1287. 1349. 1412. 1477. 1542. 1609. 1676. 1745. 1815. 1885. 1957. 2029. 2103. 2178. 2253. 2330. 2407. 2486. 2565. 2645. 2727. 2809. 2892. 2976. 3061. 3146. 3233. 3321. 34.8 52.1 71.8 93.8 118. 144. 172. 202. 234. 267. 302. 339. 377. 416. 458. 500. 544. 589. 636. 684. 733. 784. 836. 889. 943. 998. 1055. 1113. 1172. 1232. 1293. 1355. 1419. 1483. 1549. 1615. 1683. 1752. 1822. 1892. 1964. 2037. 2110. 2185. 2261. 2337. 2415. 2494. 2573. 2653. 2735. 2817. 2900. 2984. 3069. 3155. 3242. 3329.
0.00 27.2 43.1 61.6 82.5 106. 131. 158. 187. 218. 250. 284. 320. 358. 396. 437. 479. 522. 567. 613. 660. 708. 758. 810. 862. 916. 971. 1027. 1084. 1142. 1202. 1262. 1324. 1387. 1451. 1516. 1582. 1649. 1717. 1787. 1857. 1928. 2000. 2073. 2148. 2223. 2299. 2376. 2454. 2533. 2613. 2694. 2776. 2859. 2942. 3027. 3112. 3198. 3286.
0.01 28.7 44.9 63.6 84.7 108. 133. 161. 190. 221. 254. 288. 324. 361. 400. 441. 483. 526. 571. 617. 665. 713. 763. 815. 867. 921. 976. 1032. 1090. 1148. 1208. 1268. 1330. 1393. 1457. 1523. 1589. 1656. 1724. 1794. 1864. 1935. 2008. 2081. 2155. 2230. 2307. 2384. 2462. 2541. 2621. 2702. 2784. 2867. 2951. 3035. 3121. 3207. 3294.
0.02 30.2 46.6 65.6 87.0 110. 136. 164. 193. 224. 257. 291. 328. 365. 404. 445. 487. 531. 576. 622. 669. 718. 769. 820. 873. 927. 982. 1038. 1095. 1154. 1214. 1275. 1337. 1400. 1464. 1529. 1595. 1663. 1731. 1801. 1871. 1942. 2015. 2088. 2163. 2238. 2314. 2392. 2470. 2549. 2629. 2710. 2792. 2875. 2959. 3044. 3129. 3216. 3303.
0.03 31.7 48.4 67.7 89.2 113. 139. 166. 196. 227. 260. 295. 331. 369. 408. 449. 491. 535. 580. 627. 674. 723. 774. 825. 878. 932. 987. 1044. 1101. 1160. 1220. 1281. 1343. 1406. 1470. 1536. 1602. 1670. 1738. 1808. 1878. 1950. 2022. 2096. 2170. 2246. 2322. 2399. 2478. 2557. 2637. 2718. 2801. 2884. 2967. 3052. 3138. 3224. 3312.
0.06 36.4 53.9 73.9 96.1 120. 147. 175. 205. 237. 270. 306. 342. 381. 420. 462. 504. 548. 594. 641. 689. 738. 789. 841. 894. 948. 1004. 1061. 1119. 1178. 1238. 1299. 1362. 1425. 1490. 1555. 1622. 1690. 1759. 1829. 1899. 1971. 2044. 2118. 2193. 2268. 2345. 2423. 2502. 2581. 2662. 2743. 2825. 2909. 2993. 3078. 3164. 3251. 3338.
0.07 38.1 55.8 76.0 98.5 123. 150. 178. 208. 240. 274. 309. 346. 385. 425. 466. 509. 553. 599. 646. 694. 743. 794. 846. 899. 954. 1010. 1067. 1125. 1184. 1244. 1305. 1368. 1432. 1496. 1562. 1629. 1697. 1766. 1836. 1907. 1978. 2051. 2125. 2200. 2276. 2353. 2431. 2509. 2589. 2670. 2751. 2834. 2917. 3001. 3086. 3172. 3259. 3347.
0.08 39.7 57.7 78.2 101. 126. 152. 181. 211. 244. 277. 313. 350. 389. 429. 470. 513. 557. 603. 650. 699. 748. 799. 851. 905. 959. 1015. 1072. 1130. 1190. 1250. 1312. 1374. 1438. 1503. 1569. 1636. 1704. 1773. 1843. 1914. 1986. 2059. 2133. 2208. 2284. 2361. 2439. 2517. 2597. 2678. 2759. 2842. 2925. 3010. 3095. 3181. 3268. 3356.
0.09 41.4 59.7 80.3 103. 128. 155. 184. 215. 247. 281. 317. 354. 392. 433. 474. 517. 562. 608. 655. 704. 753. 804. 857. 910. 965. 1021. 1078. 1136. 1196. 1256. 1318. 1381. 1444. 1509. 1575. 1642. 1710. 1780. 1850. 1921. 1993. 2066. 2140. 2215. 2291. 2368. 2446. 2525. 2605. 2686. 2768. 2850. 2934. 3018. 3103. 3190. 3277. 3365.
Table A9-2. Discharge of fully contracted standard submerged rectangular orifice in ft /sec. Computed from the formula Q =0.61A (2g h )
3 0.5
Head h , ft 0.01 .02 .03 .04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40
0.25 0.122 .173 .212 .245 .274 .300 .324 .346 .367 .387 .406 .424 .441 .458 .474 .490 .505 .519 .533 .547 .561 .574 .587 .600 .612 .624 .636 .648 .659 .670 .681 .692 .703 .714 .724 .734 .744 .754 .764 .774
0.5
Cross-sectional area A of orifice, square feet 0.75 1.0 1.25 1.5 1.75 0.367 .519 .636 .734 .821 .899 .971 1.04 1.10 1.16 1.22 1.27 1.32 1.37 1.42 1.47 1.51 1.56 1.60 1.64 1.68 1.72 1.76 1.80 1.84 1.87 1.91 1.94 1.98 2.01 2.04 2.08 2.11 2.14 2.17 2.20 2.23 2.26 2.29 2.32 0.490 .692 .848 .979 1.09 1.20 1.30 1.38 1.47 1.55 1.62 1.70 1.76 1.83 1.90 1.96 2.02 2.08 2.13 2.19 2.24 2.30 2.35 2.40 2.45 2.50 2.54 2.59 2.64 2.68 2.73 2.77 2.81 2.85 2.90 2.94 2.98 3.02 3.06 3.10 0.612 .865 1.06 1.22 1.37 1.50 1.62 1.73 1.84 1.94 2.03 2.12 2.21 2.29 2.37 2.45 2.52 2.60 2.67 2.74 2.80 2.87 2.93 3.00 3.06 3.12 3.18 3.24 3.30 3.35 3.41 3.46 3.52 3.57 3.62 3.67 3.72 3.77 3.82 3.87 0.734 1.04 1.27 1.47 1.64 1.80 1.94 2.08 2.20 2.32 2.44 2.54 2.65 2.75 2.84 2.94 3.03 3.12 3.20 3.28 3.36 3.44 3.52 3.60 3.67 3.74 3.82 3.89 3.95 4.02 4.09 4.15 4.22 4.28 4.34 4.41 4.47 4.53 4.59 4.64 0.857 1.21 1.48 1.71 1.92 2.10 2.27 2.42 2.57 2.71 2.84 2.97 3.09 3.21 3.32 3.43 3.53 3.63 3.73 3.83 3.93 4.02 4.11 4.20 4.28 4.37 4.45 4.53 4.61 4.69 4.77 4.85 4.92 5.00 5.07 5.14 5.21 5.28 5.35 5.42
2.0 0.979 1.38 1.70 1.96 2.19 2.40 2.59 2.77 2.94 3.10 3.25 3.39 3.53 3.66 3.79 3.92 4.04 4.15 4.27 4.38 4.49 4.59 4.70 4.80 4.90 4.99 5.09 5.18 5.27 5.36 5.45 5.54 5.62 5.71 5.79 5.87 5.96 6.04 6.11 6.19
0.245 .346 .424 .490 .547 .600 .648 .692 .734 .774 .812 .848 .882 .916 .948 .979 1.01 1.04 1.07 1.09 1.12 1.15 1.17 1.20 1.22 1.25 1.27 1.30 1.32 1.34 1.36 1.38 1.41 1.43 1.45 1.47 1.49 1.51 1.53 1.55
Table A9-2. Discharge of fully contracted standard submerged rectangular orifice in ft /sec. Computed from the formula Q =0.61A (2g h )
3 0.5
Head h , ft .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 .54 .55 .56 .57 .58 .59 .60 .61 .62 .63 .64 .65 .66 .67 .68 .69 .70 .71 .72 .73 .74 .75 .76 .77 .78 .79 .80
0.25 0.784 .793 .803 .812 .821 .830 .839 .848 .857 .865 .874 .882 .891 .899 .908 .916 .924 .932 .940 .948 .956 .964 .971 .979 .987 .994 1.00 1.01 1.02 1.02 1.03 1.04 1.05 1.05 1.06 1.07 1.07 1.08 1.09 1.09
0.5 1.57 1.59 1.61 1.62 1.64 1.66 1.68 1.70 1.71 1.73 1.75 1.76 1.78 1.80 1.82 1.83 1.85 1.86 1.88 1.90 1.91 1.93 1.94 1.96 1.97 1.99 2.00 2.02 2.03 2.05 2.06 2.08 2.09 2.11 2.12 2.13 2.15 2.16 2.18 2.19
Cross-sectional area A of orifice, square feet 0.75 1.0 1.25 1.5 1.75 2.35 2.38 2.41 2.44 2.46 2.49 2.52 2.54 2.57 2.60 2.62 2.65 2.67 2.70 2.72 2.75 2.77 2.80 2.82 2.84 2.87 2.89 2.91 2.94 2.96 2.98 3.01 3.03 3.05 3.07 3.09 3.12 3.14 3.16 3.18 3.20 3.22 3.24 3.26 3.28 3.13 3.17 3.21 3.25 3.28 3.32 3.36 3.39 3.43 3.46 3.50 3.53 3.56 3.60 3.63 3.66 3.70 3.73 3.76 3.79 3.82 3.85 3.89 3.92 3.95 3.98 4.01 4.04 4.07 4.10 4.12 4.15 4.18 4.21 4.24 4.27 4.30 4.32 4.35 4.38 3.92 3.97 4.01 4.06 4.10 4.15 4.19 4.24 4.28 4.33 4.37 4.41 4.45 4.50 4.54 4.58 4.62 4.66 4.70 4.74 4.78 4.82 4.86 4.90 4.93 4.97 5.01 5.05 5.08 5.12 5.16 5.19 5.23 5.26 5.30 5.33 5.37 5.40 5.44 5.47 4.70 4.76 4.82 4.87 4.93 4.98 5.03 5.09 5.14 5.19 5.24 5.29 5.35 5.40 5.45 5.49 5.54 5.59 5.64 5.69 5.73 5.78 5.83 5.87 5.92 5.97 6.01 6.06 6.10 6.14 6.19 6.23 6.27 6.32 6.36 6.40 6.44 6.49 6.53 6.57 5.49 5.55 5.62 5.68 5.75 5.81 5.87 5.94 6.00 6.06 6.12 6.18 6.24 6.30 6.35 6.41 6.47 6.52 6.58 6.64 6.69 6.75 6.80 6.85 6.91 6.96 7.01 7.06 7.12 7.17 7.22 7.27 7.32 7.37 7.42 7.47 7.52 7.57 7.61 7.66
2.0 6.27 6.34 6.42 6.49 6.57 6.64 6.71 6.78 6.85 6.92 6.99 7.06 7.13 7.19 7.26 7.33 7.39 7.46 7.52 7.58 7.65 7.71 7.77 7.83 7.89 7.95 8.01 8.07 8.13 8.19 8.25 8.31 8.36 8.42 8.48 8.54 8.59 8.65 8.70 8.76
Table A9-3. Discharge of rectangular submerged orifices with bottom and side contractions suppressed, in ft3/sec. Computed from the formula 0.5 Q =0.70A (2g h )
Head h , ft 0.04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 2.0 2.25 2.51 2.75 2.97 3.18 3.37 3.55 3.73 3.89 4.05 4.20 4.35 4.49 4.63 4.77 4.90 5.02 5.15 5.27 5.39 5.50 5.62 5.73 5.84 5.94 6.05 6.15 6.26 6.36 6.45 6.55 6.65 6.74 6.83 6.93 7.02 7.11 7.19 7.28 7.37 7.45 7.54 7.62 7.70 7.78 7.86 7.94 8.02 8.10 8.18 2.5 2.81 3.14 3.44 3.72 3.97 4.21 4.44 4.66 4.86 5.06 5.25 5.44 5.62 5.79 5.96 6.12 6.28 6.44 6.59 6.74 6.88 7.02 7.16 7.30 7.43 7.56 7.69 7.82 7.94 8.07 8.19 8.31 8.43 8.54 8.66 8.77 8.88 8.99 9.10 9.21 9.32 9.42 9.52 9.63 9.73 9.83 9.93 10.0 10.1 10.2 Cross-sectional area A of orifice, square feet 3.0 3.5 4.0 5.0 3.37 3.77 4.13 4.46 4.77 5.06 5.33 5.59 5.84 6.08 6.31 6.53 6.74 6.95 7.15 7.35 7.54 7.72 7.90 8.08 8.26 8.43 8.59 8.76 8.92 9.08 9.23 9.38 9.53 9.68 9.83 9.97 10.1 10.3 10.4 10.5 10.7 10.8 10.9 11.1 11.2 11.3 11.4 11.6 11.7 11.8 11.9 12.0 12.2 12.3 3.93 4.40 4.82 5.20 5.56 5.90 6.22 6.52 6.81 7.09 7.36 7.61 7.86 8.11 8.34 8.57 8.79 9.01 9.22 9.43 9.63 9.83 10.0 10.2 10.4 10.6 10.8 10.9 11.1 11.3 11.5 11.6 11.8 12.0 12.1 12.3 12.4 12.6 12.7 12.9 13.0 13.2 13.3 13.5 13.6 13.8 13.9 14.0 14.2 14.3 4.49 5.02 5.50 5.94 6.36 6.74 7.11 7.45 7.78 8.10 8.41 8.70 8.99 9.26 9.53 9.79 10.0 10.3 10.5 10.8 11.0 11.2 11.5 11.7 11.9 12.1 12.3 12.5 12.7 12.9 13.1 13.3 13.5 13.7 13.9 14.0 14.2 14.4 14.6 14.7 14.9 15.1 15.2 15.4 15.6 15.7 15.9 16.0 16.2 16.4 5.62 6.28 6.88 7.43 7.94 8.43 8.88 9.32 9.73 10.1 10.5 10.9 11.2 11.6 11.9 12.2 12.6 12.9 13.2 13.5 13.8 14.0 14.3 14.6 14.9 15.1 15.4 15.6 15.9 16.1 16.4 16.6 16.9 17.1 17.3 17.5 17.8 18.0 18.2 18.4 18.6 18.8 19.0 19.3 19.5 19.7 19.9 20.1 20.3 20.4 6.0 6.74 7.54 8.26 8.92 9.53 10.1 10.7 11.2 11.7 12.2 12.6 13.1 13.5 13.9 14.3 14.7 15.1 15.4 15.8 16.2 16.5 16.9 17.2 17.5 17.8 18.2 18.5 18.8 19.1 19.4 19.7 19.9 20.2 20.5 20.8 21.0 21.3 21.6 21.8 22.1 22.4 22.6 22.9 23.1 23.4 23.6 23.8 24.1 24.3 24.5 7.0 7.86 8.79 9.63 10.4 11.1 11.8 12.4 13.0 13.6 14.2 14.7 15.2 15.7 16.2 16.7 17.1 17.6 18.0 18.4 18.9 19.3 19.7 20.1 20.4 20.8 21.2 21.5 21.9 22.2 22.6 22.9 23.3 23.6 23.9 24.2 24.6 24.9 25.2 25.5 25.8 26.1 26.4 26.7 27.0 27.2 27.5 27.8 28.1 28.4 28.6
Table A9-3 [continued]. Discharge of rectangular submerged orifices with bottom and side contractions suppressed, in ft3/sec. Computed from the formula Q =0.70A (2g h )0.5
Head h , ft 0.04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 8.0 8.99 10.0 11.0 11.9 12.7 13.5 14.2 14.9 15.6 16.2 16.8 17.4 18.0 18.5 19.1 19.6 20.1 20.6 21.1 21.6 22.0 22.5 22.9 23.4 23.8 24.2 24.6 25.0 25.4 25.8 26.2 26.6 27.0 27.3 27.7 28.1 28.4 28.8 29.1 29.5 29.8 30.1 30.5 30.8 31.1 31.5 31.8 32.1 32.4 32.7 Cross-sectional area A of orifice, square feet 10.0 12.0 14.0 16.0 18.0 11.2 12.6 13.8 14.9 15.9 16.9 17.8 18.6 19.5 20.3 21.0 21.8 22.5 23.2 23.8 24.5 25.1 25.7 26.3 26.9 27.5 28.1 28.6 29.2 29.7 30.3 30.8 31.3 31.8 32.3 32.8 33.2 33.7 34.2 34.6 35.1 35.5 36.0 36.4 36.8 37.3 37.7 38.1 38.5 38.9 39.3 39.7 40.1 40.5 40.9 13.5 15.1 16.5 17.8 19.1 20.2 21.3 22.4 23.4 24.3 25.2 26.1 27.0 27.8 28.6 29.4 30.1 30.9 31.6 32.3 33.0 33.7 34.4 35.0 35.7 36.3 36.9 37.5 38.1 38.7 39.3 39.9 40.4 41.0 41.6 42.1 42.6 43.2 43.7 44.2 44.7 45.2 45.7 46.2 46.7 47.2 47.7 48.1 48.6 49.1 15.7 17.6 19.3 20.8 22.2 23.6 24.9 26.1 27.2 28.4 29.4 30.5 31.5 32.4 33.4 34.3 35.2 36.0 36.9 37.7 38.5 39.3 40.1 40.9 41.6 42.4 43.1 43.8 44.5 45.2 45.9 46.5 47.2 47.8 48.5 49.1 49.7 50.4 51.0 51.6 52.2 52.8 53.3 53.9 54.5 55.1 55.6 56.2 56.7 57.3 18.0 20.1 22.0 23.8 25.4 27.0 28.4 29.8 31.1 32.4 33.6 34.8 36.0 37.1 38.1 39.2 40.2 41.2 42.2 43.1 44.0 44.9 45.8 46.7 47.6 48.4 49.2 50.0 50.8 51.6 52.4 53.2 53.9 54.7 55.4 56.1 56.8 57.6 58.2 58.9 59.6 60.3 61.0 61.6 62.3 62.9 63.6 64.2 64.8 65.4 20.2 22.6 24.8 26.8 28.6 30.3 32.0 33.5 35.0 36.5 37.8 39.2 40.4 41.7 42.9 44.1 45.2 46.3 47.4 48.5 49.5 50.6 51.6 52.5 53.5 54.5 55.4 56.3 57.2 58.1 59.0 59.8 60.7 61.5 62.3 63.1 64.0 64.7 65.5 66.3 67.1 67.8 68.6 69.3 70.1 70.8 71.5 72.2 72.9 73.6 20.0 22.5 25.1 27.5 29.7 31.8 33.7 35.5 37.3 38.9 40.5 42.0 43.5 44.9 46.3 47.7 49.0 50.2 51.5 52.7 53.9 55.0 56.2 57.3 58.4 59.4 60.5 61.5 62.6 63.6 64.5 65.5 66.5 67.4 68.3 69.3 70.2 71.1 71.9 72.8 73.7 74.5 75.4 76.2 77.0 77.8 78.6 79.4 80.2 81.0 81.8
Table A9-3 [continued]. Discharge of rectangular submerged orifices with bottom and side contractions suppressed, in ft3/sec. Computed from the formula Q =0.70A (2g h )0.5
Head h , ft 0.04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 22 24.7 27.6 30.3 32.7 35.0 37.1 39.1 41.0 42.8 44.6 46.2 47.9 49.4 51.0 52.4 53.9 55.3 56.6 58.0 59.3 60.5 61.8 63.0 64.2 65.4 66.6 67.7 68.8 69.9 71.0 72.1 73.1 74.2 75.2 76.2 77.2 78.2 79.1 80.1 81.0 82.0 82.9 83.8 84.7 85.6 86.5 87.4 88.3 89.1 90.0 24 27.0 30.1 33.0 35.7 38.1 40.4 42.6 44.7 46.7 48.6 50.4 52.2 53.9 55.6 57.2 58.8 60.3 61.8 63.2 64.7 66.0 67.4 68.7 70.1 71.3 72.6 73.8 75.1 76.3 77.4 78.6 79.8 80.9 82.0 83.1 84.2 85.3 86.3 87.4 88.4 89.4 90.4 91.4 92.4 93.4 94.4 95.3 96.3 97.2 98.1 Cross-sectional area A of orifice, square feet 26 28 30 32 29.2 32.7 35.8 38.6 41.3 43.8 46.2 48.4 50.6 52.7 54.6 56.6 58.4 60.2 62.0 63.7 65.3 66.9 68.5 70.0 71.6 73.0 74.5 75.9 77.3 78.7 80.0 81.3 82.6 83.9 85.2 86.4 87.6 88.8 90.0 91.2 92.4 93.5 94.7 95.8 96.9 98.0 99.1 100. 101. 102. 103. 104. 105. 106. 31.5 35.2 38.5 41.6 44.5 47.2 49.7 52.2 54.5 56.7 58.9 60.9 62.9 64.9 66.7 68.6 70.3 72.1 73.8 75.4 77.1 78.6 80.2 81.7 83.2 84.7 86.2 87.6 89.0 90.4 91.7 93.1 94.4 95.7 97.0 98.2 99.5 101. 102. 103. 104. 106. 107. 108. 109. 110. 111. 112. 113. 115. 33.7 37.7 41.3 44.6 47.7 50.6 53.3 55.9 58.4 60.8 63.1 65.3 67.4 69.5 71.5 73.5 75.4 77.2 79.0 80.8 82.6 84.3 85.9 87.6 89.2 90.8 92.3 93.8 95.3 96.8 98.3 99.7 101. 103. 104. 105. 107. 108. 109. 111. 112. 113. 114. 116. 117. 118. 119. 120. 122. 123. 36.0 40.2 44.0 47.6 50.8 53.9 56.8 59.6 62.3 64.8 67.3 69.6 71.9 74.1 76.3 78.4 80.4 82.4 84.3 86.2 88.1 89.9 91.7 93.4 95.1 96.8 98.5 100. 102. 103. 105. 106. 108. 109. 111. 112. 114. 115. 116. 118. 119. 121. 122. 123. 125. 126. 127. 128. 130. 131. 34 38.2 42.7 46.8 50.5 54.0 57.3 60.4 63.3 66.2 68.9 71.5 74.0 76.4 78.7 81.0 83.3 85.4 87.5 89.6 91.6 93.6 95.5 97.4 99.2 101. 103. 105. 106. 108. 110. 111. 113. 115. 116. 118. 119. 121. 122. 124. 125. 127. 128. 130. 131. 132. 134. 135. 136. 138. 139. 36 40.4 45.2 49.5 53.5 57.2 60.7 64.0 67.1 70.1 72.9 75.7 78.3 80.9 83.4 85.8 88.1 90.4 92.7 94.9 97.0 99.1 101. 103. 105. 107. 109. 111. 113. 114. 116. 118. 120. 121. 123. 125. 126. 128. 129. 131. 133. 134. 136. 137. 139. 140. 142. 143. 144. 146. 147.
Table A9-3 [continued]. Discharge of rectangular submerged orifices with bottom and side contractions suppressed, in ft3/sec. Computed from the formula Q =0.70A (2g h )0.5
Head h , ft 0.04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 38 42.7 47.7 52.3 56.5 60.4 64.0 67.5 70.8 73.9 77.0 79.9 82.7 85.4 88.0 90.6 93.0 95.5 97.8 100. 102. 105. 107. 109. 111. 113. 115. 117. 119. 121. 123. 124. 126. 128. 130. 132. 133. 135. 137. 138. 140. 142. 143. 145. 146. 148. 149. 151. 152. 154. 155. 40 Cross-sectional area A of orifice, square feet 42 44 46 48 47.2 52.8 57.8 62.4 66.7 70.8 74.6 78.3 81.7 85.1 88.3 91.4 94.4 97.3 100. 103. 106. 108. 111. 113. 116. 118. 120. 123. 125. 127. 129. 131. 133. 136. 138. 140. 142. 144. 145. 147. 149. 151. 153. 155. 157. 158. 160. 162. 163. 165. 167. 168. 170. 172. 49.4 55.3 60.5 65.4 69.9 74.2 78.2 82.0 85.6 89.1 92.5 95.7 98.9 102. 105. 108. 111. 113. 116. 119. 121. 124. 126. 128. 131. 133. 135. 138. 140. 142. 144. 146. 148. 150. 152. 154. 156. 158. 160. 162. 164. 166. 168. 169. 171. 173. 175. 177. 178. 180. 51.7 57.8 63.3 68.4 73.1 77.5 81.7 85.7 89.5 93.2 96.7 100. 103. 107. 110. 113. 116. 118. 121. 124. 127. 129. 132. 134. 137. 139. 142. 144. 146. 148. 151. 153. 155. 157. 159. 161. 163. 165. 167. 169. 171. 173. 175. 177. 179. 181. 183. 185. 186. 188. 53.9 60.3 66.0 71.3 76.3 80.9 85.3 89.4 93.4 97.2 101. 104. 108. 111. 114. 118. 121. 124. 126. 129. 132. 135. 137. 140. 143. 145. 148. 150. 153. 155. 157. 160. 162. 164. 166. 168. 171. 173. 175. 177. 179. 181. 183. 185. 187. 189. 191. 193. 194. 196. 50 56.2 62.8 68.8 74.3 79.4 84.3 88.8 93.2 97.3 101. 105. 109. 112. 116. 119. 122. 126. 129. 132. 135. 138. 140. 143. 146. 149. 151. 154. 156. 159. 161. 164. 166. 169. 171. 173. 175. 178. 180. 182. 184. 186. 188. 190. 193. 195. 197. 199. 201. 203. 204.
44.9 50.2 55.0 59.4 63.6 67.4 71.1 74.5 77.8 81.0 84.1 87.0 89.9 92.6 95.3 97.9 100. 103. 105. 108. 110. 112. 115. 117. 119. 121. 123. 125. 127. 129. 131. 133. 135. 137. 139. 140. 142. 144. 146. 147. 149. 151. 152. 154. 156. 157. 159. 160. 162. 164.
Table A9-3 [continued]. Discharge of rectangular submerged orifices with bottom and side contractions suppressed, in ft3/sec. Computed from the formula Q =0.70A (2g h )0.5
Head h , ft 0.04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 55 61.8 69.1 75.7 81.7 87.4 92.7 97.7 102. 107. 111. 116. 120. 124. 127. 131. 135. 138. 142. 145. 148. 151. 154. 158. 161. 163. 166. 169. 172. 175. 177. 180. 183. 185. 188. 190. 193. 195. 198. 200. 203. 205. 207. 210. 212. 214. 216. 218. 221. 223. 225. 60 67.4 75.4 82.6 89.2 95.3 101. 107. 112. 117. 122. 126. 131. 135. 139. 143. 147. 151. 154. 158. 162. 165. 169. 172. 175. 178. 182. 185. 188. 191. 194. 197. 199. 202. 205. 208. 210. 213. 216. 218. 221. 224. 226. 229. 231. 234. 236. 238. 241. 243. 245. Cross-sectional area A of orifice, square feet 65 70 75 80 73.0 81.6 89.4 96.6 103. 110. 115. 121. 126. 132. 137. 141. 146. 151. 155. 159. 163. 167. 171. 175. 179. 183. 186. 190. 193. 197. 200. 203. 207. 210. 213. 216. 219. 222. 225. 228. 231. 234. 237. 239. 242. 245. 248. 250. 253. 256. 258. 261. 263. 266. 78.6 87.9 96.3 104. 111. 118. 124. 130. 136. 142. 147. 152. 157. 162. 167. 171. 176. 180. 184. 189. 193. 197. 201. 204. 208. 212. 215. 219. 222. 226. 229. 233. 236. 239. 242. 246. 249. 252. 255. 258. 261. 264. 267. 270. 272. 275. 278. 281. 284. 286. 84.3 94.2 103. 111. 119. 126. 133. 140. 146. 152. 158. 163. 169. 174. 179. 184. 188. 193. 198. 202. 206. 211. 215. 219. 223. 227. 231. 235. 238. 242. 246. 249. 253. 256. 260. 263. 266. 270. 273. 276. 279. 283. 286. 289. 292. 295. 298. 301. 304. 307. 89.9 100. 110. 119. 127. 135. 142. 149. 156. 162. 168. 174. 180. 185. 191. 196. 201. 206. 211. 216. 220. 225. 229. 234. 238. 242. 246. 250. 254. 258. 262. 266. 270. 273. 277. 281. 284. 288. 291. 295. 298. 301. 305. 308. 311. 315. 318. 321. 324. 327. 85 95.5 107. 117. 126. 135. 143. 151. 158. 165. 172. 179. 185. 191. 197. 203. 208. 214. 219. 224. 229. 234. 239. 243. 248. 253. 257. 262. 266. 270. 274. 278. 282. 286. 290. 294. 298. 302. 306. 309. 313. 317. 320. 324. 327. 331. 334. 338. 341. 344. 348. 90 101. 113. 124. 134. 143. 152. 160. 168. 175. 182. 189. 196. 202. 208. 214. 220. 226. 232. 237. 242. 248. 253. 258. 263. 268. 272. 277. 281. 286. 290. 295. 299. 303. 308. 312. 316. 320. 324. 328. 332. 335. 339. 343. 347. 350. 354. 357. 361. 365. 368.
Table A9-3 [continued]. Discharge of rectangular submerged orifices with bottom and side contractions suppressed, in ft3/sec. Computed from the formula Q =0.70A (2g h )0.5
Head h , ft 0.04 .05 .06 .07 .08 .09 .10 .11 .12 .13 .14 .15 .16 .17 .18 .19 .20 .21 .22 .23 .24 .25 .26 .27 .28 .29 .30 .31 .32 .33 .34 .35 .36 .37 .38 .39 .40 .41 .42 .43 .44 .45 .46 .47 .48 .49 .50 .51 .52 .53 95 107 119 131 141 151 160 169 177 185 192 200 207 213 220 226 233 239 245 250 256 261 267 272 277 282 287 292 297 302 307 311 316 320 325 329 333 338 342 346 350 354 358 362 366 370 374 377 381 385 389 Cross-sectional area A of orifice, square feet 100 105 110 115 120 112 126 138 149 159 169 178 186 195 203 210 218 225 232 238 245 251 257 263 269 275 281 286 292 297 303 308 313 318 323 328 332 337 342 346 351 355 360 364 368 373 377 381 385 389 393 397 401 405 409 118 132 144 156 167 177 187 196 204 213 221 228 236 243 250 257 264 270 277 283 289 295 301 306 312 318 323 328 334 339 344 349 354 359 364 368 373 378 382 387 391 396 400 404 409 413 417 421 425 429 124 138 151 163 175 185 195 205 214 223 231 239 247 255 262 269 276 283 290 296 303 309 315 321 327 333 338 344 350 355 360 366 371 376 381 386 391 396 400 405 410 415 419 424 428 433 437 441 446 450 129 144 158 171 183 194 204 214 224 233 242 250 258 266 274 282 289 296 303 310 316 323 329 336 342 348 354 360 365 371 377 382 388 393 398 403 409 414 419 424 429 433 438 443 448 452 457 461 466 470 135 151 165 178 191 202 213 224 234 243 252 261 270 278 286 294 301 309 316 323 330 337 344 350 357 363 369 375 381 387 393 399 404 410 416 421 426 432 437 442 447 452 457 462 467 472 477 481 486 491 125 140 157 172 186 199 211 222 233 243 253 263 272 281 290 298 306 314 322 329 337 344 351 358 365 372 378 385 391 397 403 409 415 421 427 433 439 444 450 455 460 466 471 476 481 486 492 497 501 506 511
Table A9-4. Discharge of constant-head orifice (CHO) turnout in ft /sec. Capacity is 20 ft3/sec, gate size is 30 by 24 inches, h =0.20 feet.
Discharge ft /sec 0.25 .50 .75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00 5.25 5.50 5.75 6.00 6.25 6.50 6.75 7.00 7.25 7.50 7.75 8.00 8.25 8.50 8.75 9.00 9.25 9.50 9.75 10.00
3
Gate opening in feet 2 gates 1 gate 0.02 .04 .06 .08 .10 .12 .14 .16 .18 .20 .22 .24 .26 .28 .30 .32 .34 .36 .38 .40 .42 .44 .46 .48 .50 .52 .54 .56 .58 .60 .62 .64 .66 .68 .70 .72 .74 .76 .775 .80 0.04 .08 .12 .16 .20 .24 .28 .32 .36 .40 .44 .48 .52 .56 .60 .64 .68 .72 .755 .79 .83 .87 .91 .95 .99 1.03 1.065 1.10 1.14 1.18 1.22 1.26 1.30 1.34 1.375 1.41 1.45 1.49 1.525 1.56
Discharge ft /sec 10.25 10.50 10.75 11.00 11.25 11.50 11.75 12.00 12.25 12.50 12.75 13.00 13.25 13.50 13.75 14.00 14.25 14.50 14.75 15.00 15.25 15.50 15.75 16.00 16.25 16.50 16.75 17.00 17.25 17.50 17.75 18.00 18.25 18.50 18.75 19.00 19.25 19.50 19.75 20.00
3
Gate opening in feet 2 gates 1 gate 0.81 .83 .85 .87 .89 .91 .93 .95 .97 .99 1.01 1.03 1.05 1.07 1.085 1.10 1.12 1.14 1.16 1.18 1.20 1.22 1.24 1.26 1.28 1.30 1.32 1.34 1.355 1.37 1.39 1.41 1.43 1.45 1.47 1.49 1.51 1.53 1.545 1.56 -----------------------------------------------------------------------------------------------------------------------------------------------------------------
Table A9-5. Discharge of constant-head orifice (CHO) turnout in ft /sec. Capacity is 10 ft3/sec, gate size is 24 by 18 inches, h =0.20 feet.
Discharge ft /sec 0.25 .50 .75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 3.25 3.50 3.75 4.00 4.25 4.50 4.75 5.00
3
Gate opening in feet 2 gates 1 gate 0.025 .05 .075 .10 .125 .15 .175 .20 .225 .25 .275 .30 .325 .35 .375 .40 .425 .45 .475 .50 0.05 .10 .15 .20 .25 .30 .35 .40 .45 .50 .55 .60 .65 .70 .745 .79 .84 .89 .94 .99
Discharge ft /sec 5.25 5.50 5.75 6.00 6.25 6.50 6.75 7.00 7.25 7.50 7.75 8.00 8.25 8.50 8.75 9.00 9.25 9.50 9.75 10.00
3
Gate opening in feet 2 gates 1 gate 0.525 .55 .575 .60 .625 .65 .675 .70 .722 .74 .765 .79 .815 .84 .865 .89 .915 .94 .965 .99 ---------------------------------------------------------------------------------
Table A9-6. Discharges for standard sized constant-head orifice (CHO) turnouts (Aisenbrey, 1978).
Orifice gate openings in feet, for various size turnouts Gate width Discharge ft 3 /sec 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 14.0 15.0 16.0 18.0 20.0 21.0 22.0 24.0 30.0
18 inch 18 inch 24 inch 30 inch 30 inch 36 inch 15-ft3/sec turnout 42 inch 18-ft3/sec turnout 48 inch 24-ft3/sec turnout 48 inch 30-ft3/sec turnout 2-ft3/sec 4-ft3/sec 6-ft3/sec 9-ft3/sec 12-ft3/sec turnout turnout turnout turnout turnout
0.16 .32 .48 .64 .80 .96 1.12 1.27 1.43 -------------------------------------------------
0.16 .32 .48 .64 .80 .96 1.12 1.27 1.43 1.59 1.75 1.91 -------------------------------------
0.13 .27 .40 .53 .66 .80 .93 1.06 1.19 1.33 1.46 1.59 1.86 1.99 -----------------------------
0.11 .23 .34 .46 .57 .68 .80 .91 1.02 1.14 1.25 1.37 1.59 1.71 1.82 2.05 ---------------------
0.10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.19 1.39 1.49 1.59 1.79 1.99 2.09 2.19 2.39 -----
0.10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 1.20 1.39 1.49 1.59 1.79 1.99 2.09 2.19 2.39 2.99