CATALOGUE
www.dakshglobal.com
2 COMPANY PROFILE 2023/24
WHY
DAKSH ?
EN-54, NFPA-72, ERTL,
BIS & STQC Complied Fire
Detection Systems
ABOUT US
Daksh second edition of the Fire Detection System and Life Safety products catalogue
contains innovative and intelligent products for a broad range of applications in life safety
domain.
Respecting the strictest National, International laws, standards of product and service
quality, Daksh activities are accredited to ISO9001, EN54, STQC, CE etc. Our
customers have the confidence that Daksh electronics can provide complete solution
as per the need of site and building users. This is made possible via a strong network
of R&D professionals, service team members and In-house manufacturing unit. Daksh
Electricals is among the very few companies which continually invests huge budget on
R&D and service networks.
Daksh is unconditionally and entirely “MAKE IN INDIA”
brand with its state-of-the-art manufacturing and R&D
facility in New Delhi and Uttarakhand. Daksh is one of
the most ethical and reliable brand with having experi-
ence of serving the Nation and Government of India for
more than 20 Years.
4 COMPANY PROFILE 2023/24
INTELLIGENT ADDRESSABLE
FIRE ALARM CONTROL
PANEL MULTILOOP
An addressable fire alarm control panel is a central device that manages and monitors
a network of addressable fire alarm devices, such as smoke detectors, heat detectors,
pull stations, and other devices that are interconnected using a digital communication
protocol.
Details
DE-ML-9DAi
Works on CAN bus communication protocol
Network association
INTELLIGENT ADDRESSABLE
FIRE ALARM CONTROL
PANEL 2 LOOP
The “2 loops” refer to the number of separate circuits or “loops” that can be
connected to the control panel. Each loop can support a 250 addressable devices in
any combination.This control panel is used where the number of addressable devices
are low.
Details
DE-LB-9AI
Works on CAN bus communication protocol
Network association
OVERVIEW
FIRE DETECTORS
Daksh Electronics offers a range of Intelligent Addressable fire detectors and Conven-
tional Fire Detectors. These PLC-based detectors use thermistors and the principle of
the photoelectric effect. The detectors comes with unique features like pinpoint
addressing, drift compensation and dual LED indications.
We Offer Different
Types of Detectors
and Bases
Generlists
Intelligent Addressable
Fire detectors
Semi/Hybrid
Addresable Fire
Detectors
ADDRESSABLE
HEAT & SMOKE
MULTICRITERIA DETECTOR
An Addressable Multi Detector is a type of fire alarm system device that is capable
of detecting smoke along with heat. This analog addressable device uses an optical
Sensing chamber as well as thermistor based heat sensor to Detect Fire. Addressing of
these devices shall be done manually via external hand held programmer.
Details
DE-HSD-9I
Soft addressing by use of handheld address
programmer.
EN54 Complied.
Drift compensation
ADDRESSABLE
HEAT DETECTOR
An Addressable Heat Detector is a type of fire alarm system device that is designed
to detect the increase in temperature that occurs when a fire starts. This device uses
thermistor as sensor to detect fire like situation. Addressing of these devices can be
done by using hand held programmer device.
Details
DE-HD-9I
Stable comm. technique with noise immunity.
EN54 complied.
ADDRESSABLE
SMOKE DETECTOR
An addressable smoke detector is a type of smoke detector that is connected to a fire
alarm control panel via a communication network. Unlike conventional smoke detectors,
which are wired in parallel to a control panel and cannot distinguish between different
detectors, addressable detectors have a unique identification code that allows the
control panel to determine the exact location of the detector that has detected smoke
or fire.
Details
DE-SD-9I
Soft addressing by use of handheld address
programmer.
EN54 Complied.
Drift compensation
ADDRESSABLE
CONTROL MODULE
An addressable control module is a device of a fire alarm system that is used to
control and change a specific output or device, such as a notification appliance or
damper.
Details
DE-CM-9I
Built-in identification automatically identifies third
party devices to the control panel.
ADDRESSABLE
MONITOR MODULE
An addressable monitor module is a device used in fire alarm systems to monitor the
status of a connected fire alarm device and report that status to the main fire alarm
control panel.
Details
Integral LED “blinks” RED each time a communica- Available in upto 16 way module
tion is received from the control panel and turns on
in steady red when activated. Compatible with DAKSH panel.
Relay Automatically Reset when panel resets or In Micro controller based device.
case of power failure.
Low standby current.
Internal circuitry and relay powered directly by two-
wire SLC loop. Fully confirms IS: 2189
12 COMPANY PROFILE 2023/24
ADDRESSABLE
INPUT MODULE
An addressable input module is a component of a fire alarm system that is used to
monitor a specific input or detector and provide information about its status to the
main control panel.
Details
DE-IM-9I
Integral LED “blinks” RED each time
a communication is received from
the control panel and turns on in
steady red when activated.
Addressable –analog
communication
ADDRESSABLE
MANUAL CALL POINT
An addressable manual call point is a type of device used in fire alarm systems to
manually trigger an alarm in the event of a fire or emergency. It is designed to be eas-
ily accessible and identifiable, and is typically located in strategic locations throughout
a building, such as near exits or in areas where a fire is most likely to occur.
Details
DE-MCP-9I
Sends manual alarm signal to control
panel via 2-wire bus.
Anti-tamper facility.
ADDRESSABLE
HOOTER CUM FLASHER
An alarm with flasher is a type of warning device that combines an audible alarm with
a flashing light. It is commonly used in settings where a traditional audible alarm may
not be sufficient to alert people to potential hazards or emergencies.
Details
DE-HCF-MINI
24 Volt DC operation
Flash indication.
Attractive look
ADDRESSABLE
ACTIVE FIRE
REPEATER PANEL
An addressable fire alarm control panel is a central device that manages and monitors
a network of addressable fire alarm devices, such as smoke detectors, heat detectors,
pull stations, and other devices that are interconnected using a digital communication
protocol.
Details
DE-REP-9I
Works on CAN bus Communication Protocol.
Microcontroller based.
Lower consumption.
Easy Installation.
ADDRESSABLE
MAIN PANEL
SMOKE
DETECTOR
REPEATERS
HEAT
DETECTOR
UP TO
250 ADDRESSABLE
MULTICRITERIA DEVICES
UP TO 16 DETECTOR
ADDRESSABLE PANEL
FLOW SWITCH
INPUT
MODULE
DRY CONTACT
SPEAKER
CONTROL
LIGHT MODULE
MOTOR
ADDRESSABLE
PANEL
MANUAL
CALL POINT
MONITOR
MODULE
CONVENTIONAL
SMOKE, HEAT, MULTI,MCP
EMPHASIS ON R&D
When you invest in security and safety
technology, your investments should be secure.
The innovative, future-oriented nature of Daksh
products is a direct result of our high priority
on Research & Development. We invest a large
portion of our budget in our in-house R&D.
The result speaks for themselves as the hold of
Daksh in Addressable Fire System and the newly
introduced hybrid technology.
TEAM WORK
We foster an environment that encourages
innovation, creativity and results through
teamwork. We practice leadership that teaches,
inspires and promotes full participation and
career development. We encourage open and
effective communication and interaction to
maintain transparency between our
departments.
EXCELLENCE
We continually work on improving our products,
our processes and ourselves. We always strive
to understand our customer’s businesses and
help them achieve their goals. We are dedicated
to diversity, fair treatment, mutual respect and
trust.
THOUGHT
Continually improving Quality of Products by
replacing discrete components with SMD
components. Process & Systems-By introduc-
ing Pick and placement machines, Reflow oven,
Stencil Printers etc. Fulfilling customer require-
ments through involvement of employees