Online UPS

MF Series
1~3kVA

Application:
For all kind of ADP Machines

IS 16242 (Part 1)/


IEC 62040-1

ISO 9001 ISO 14001 OHSAS 18001 ISO 27001


Control Panel
up to 50 Items Set by LCD R-85001546

Features: Rear Panel


= True Online, Double Conversion & PWM Technology. 1. RS232
= Fully Digitized Microprocessor Control, High 2. Intelligent Slot / SNMP(Optional)
Frequency & Pure Sine Wave Output. 3. External Battery (Optional)
4. Fan
= LCD Display and Wide Input Voltage Range
5. Output Sockets
= High Input Power Factor >0.99
6. Power Breaker
= Static Bypass and manual bypass
7. Input
= IGBT Based - Inverter & Rectifier
8. Output Terminal Block
= Isolation Transformer Compatible
9. EPO (Optional)
= Advanced Battery Management
= Automatic Battery Charge in UPS Off Mode
= EMI/RFI and Noise Filter
2
= Generator and Solar Compatible 1

= High Reliability Digital Control


3
= Auto-start Function & cold start feature
= ECO Mode & CMS Software integration option 4

9 8
7
Technical Specifications of MF Series Internal Battery Model 1~3kVA
MODEL MF1101B3 MF1102B8 MF1103B8
Capacity (VA) 1000 2000 3000
INPUT
Nominal Voltage 220V/230V/240V AC (1Ph+N+PE, 3 Wire)
Operating Voltage Range 100V~300V AC Load Dependent
Operating Frequency Range 50 / 60 Hz ± 10% (Auto Sensing)
Power Factor >0.99
OUTPUT
Output Voltage/Power Factor 220V / 230V / 240V AC / ±1% / 0.8 Std., 0.9 Optional
Output Frequency Auto Sensing 50 / 60 Hz ± 1~10% Sync Mode (Configurable), 50/60 Hz ± 0.1 Hz Battery Mode
Harmonic Distortion (THDv) ≤1%
Crest Factor 3:1
Efficiency 94.0% Dual Conversion Mode, 99.0% ECO Mode
BATTERY
DC Voltage 36V 96V 96V
Battery Type & Number 12V/7AH x 03 12V/7AH x 08 12V/7AH x 08
Backup Time (50% Load) 12 Min. 19 Min. 16 Min.
Backup Time (Full Load) 05 Min. 08 Min. 05 Min.
Charge Current 1A 1A 1A
Typical Recharge Time 4-5 Hours (90% of full capacity)
SYSTEM FEATURES

LCD Indication Input Voltage/Frequency, Output Voltage/Frequency, Battery Voltage, Load Watt/VA and %, Inverter Temperature,
Operation Mode such as “On Line”, “ON Batt” or On “Bypass”, Fault Codes, Battery & Load Bar graph
LED Indication Normal Operation, Bypass, Abnormal, Fault and Battery Mode
Alarms / Protection Batt. Low, DC High, Inverter Under/Over Voltage, UPS Over Load, Short Circuit, Fan Failure and UPS Fault.
Overload Capability ≤ 125% for 10 min, >125-150% for 1 min, >150% for 200 ms
Transfer Time AC to Battery : 0ms, Inverter to Bypass : 4ms (Typical)
ENVIRONMENTAL
Temperature Operating: 0~50°C*, Storage: -15ºC ~ 60ºC
Humidity / Altitude 0~95% RH Non-condersing / <1500m No derating
Noise ≤45dBA
PHYSICAL
Dimension WxDxH (mm) 144x400x215 192x469x399
Weight (Kg) 11.2 26.7 26.7
STANDARDS
Quality ISO 9001, ISO 14001, ISO 27001, ISO 45001, ISO 50001, BIS, RoHS
Safety IEC/EN62040-1
EMC / Performance IEC/EN62040-2; IEC/EN62040-3, Complying to CE
COMMUNICATION INTERFACE
Standard RS-232
Optional SNMP / ModBus / Dry Contact / USB / RS-485
Monitoring Software NetAgent Utility v5.8 / View Power / UPSilon 2000 / Muser 4000
*Conditions apply.
Specifications are subject to change without prior notice.

Best Power Equipments India Pvt. Ltd.


Corporate Office: G-240, Sector-63, Distt. Gautam Buddh Nagar, Noida-201307 UP
Registered Office: 812A, Shakuntala Building, 59, Nehru Place, New Delhi-110019
PH: +91 120 4637000-0029 | Mobile: +91 9311995859 | Email: crm@bpe.co.in
support@bpeeservices.com | Toll Free: 1800 103 1247 | Website: www.bpee.com

You might also like