Nothing Special   »   [go: up one dir, main page]

TMC2 NPT

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

TMC2

TMC2
TMC2 ALUMINUM GLOBALLY APPROVED,
HAZARDOUS (CLASSIFIED) LOCATION CABLE GLAND

FOR MC, MC-HL, INTERLOCKED & TECK ARMORED CABLES


 implified two part design
S
Compact slim profile
Independent sealing and armor clamping
Simple, sequential installation process
No disassembly required
O -ring face seal as standard
Hub not required
+110˚C
Low Impedance Copper Plated Stainless Steel 360° Grounding Spring
- 60˚C to +110˚C (-76˚F to +230˚F)
-60˚C
Globally marked, cCSAus, IECEx, ATEX and UKEX

TECHNICAL CLASSIFICATION GLOBAL PRODUCT CERTIFICATION


DESIGN SPECIFICATION BS 6121:Part 1:1989, IEC 62444, EN 62444 ATEX CERTIFICATE CML18ATEX1335X
IECEx CERTIFICATE IECEx CML 18.0192X
MECHANICAL CLASSIFICATION* Impact = Level 8, Cable Anchorage = Type D UKEX CERTIFICATE CML 21UKEX1262X
ENCLOSURE PROTECTION IK10 to IEC 62262 (20 joules) Brass and Stainless Steel only ^II 2G 1D, Ex eb IIC Gb,
CODE OF PROTECTION CODE OF PROTECTION Ex eb IIC Gb, Ex ta IIIC Da
Ex ta IIIC Da
INGRESS PROTECTION RATING** IP66
COMPLIANCE STANDARDS EN 60079-0,7 COMPLIANCE STANDARDS IEC 60079-0,7,31
NEMA RATING** Type 4X
cCSAus CERTIFICATE 2194053
CABLE GLAND MATERIAL Copper Free (<0.4%) Aluminum, Stainless Steel, Electroless Nickel Plated Brass Class II, Div 1 and 2, Groups E, F, and G; Class III, Div 1 and 2; Encl. Type 4X; Ex e II;
CSAus CODE OF PROTECTION
Class I, Zone 1, AEx e II; AEx ta IIIC
SEAL MATERIAL CMP SOLO LSF Halogen Free Thermoset Elastomer
Class I, Div 2, Groups A, B, C, and D; Class II, Div 1 and 2, Groups E, F, and G;
Corrugated & Interlocked Metal Clad Armor (MC) or TECK90, Continuously Welded Metal
CABLE TYPE cCSA CODE OF PROTECTION Class III, Div 1 and 2; Encl. Type 4X; Ex e II; Class I, Zone 1, AEx e II; AEx ta IIIC
Clad Armor (MC-HL), ACIC-HL, ACWU90-HL, RC90-HL, RA90-HL
Class I, Zone 1, AEx e II; AEx ta IIC
ARMOR CLAMPING Low Impedance Copper Plated Stainless Steel 360° Grounding Spring CAN/CSA-C22.2 No 0-10,18-04,25-1966,30-M1986,174-M1984,94-M91,
JACKET SEALING TECHNIQUE CMP Load Retention Seal COMPLIANCE STANDARDS ANSI/UL 2225, ANSI/UL 50, ANSI/UL 514B, CAN/CSA-E61241-1-1,
CAN/CSA-C22.2 No.60079-0:07,7:07
SEALING AREA(S) Cable Outer Jacket
ECAS CERTIFICATE 20-02-06425 UkrSEPRO CERTIFICATE CЦ 19.0371X 
* Mechanical and Electrical Classifications applied as per IEC 62444 and EN 62444
** When CMP installation accessories are used. Refer to www.cmp-products.com for further RETIE APPROVAL NUMBER 03866 CCOE / PESO (INDIA) CERTIFICATE P444949
AMERICAS HAZARDOUS LOCATION CABLE GLANDS

information.
CCC CERTIFICATE 2020322313003284
MARINE APPROVALS LRS: 01/00172, DNV: TAE000000Y, ABS: 20-2022051-PDA, BV: 43180

ORDER REFERENCE CABLE JACKET THRU ACROSS ACROSS


ENTRY THREAD ‘C’ CABLE ARMOR DIAMETER ‘A’ APPROX
(NPT SUFFIX REQUIRED) MINIMUM DIAMETER ‘B’ BORE ‘G’ FLATS ‘D’ CORNERS ‘D’ NOMINAL
WEIGHT
THREAD ASSEMBLY SHROUD
ARMOR STOP IN ARMOR STOP OUT ALUMINUM
NPT LENGTH ‘E’ LENGTH ‘F’
ALUMINUM NICKEL PLATED BRASS STAINLESS STEEL NPT MIN MAX MAX MAX MAX (oz)
OPTION MIN MAX MIN MAX
TMC2050A075 TMC2050NB075 TMC2050SS075 ½” - 0.78 0.42 0.55 0.55 0.63 0.51 PVC06
0.50 0.75 1.20 1.32 2.44 2.29
TMC2075A075 TMC2075NB075 TMC2075SS075 - ¾” 0.80 0.42 0.55 0.55 0.63 0.51 PVC09
TMC2050A099 TMC2050NB099 TMC2050SS099 ½” - 0.78 0.60 0.65 0.65 0.89 0.61
0.69 0.99 1.48 1.63 2.96 PVC09 3.00
TMC2075A099 TMC2075NB099 TMC2075SS099 - ¾” 0.80 0.60 0.78 0.78 0.89 0.75
TMC2075A118 TMC2075NB118 TMC2075SS118 ¾” - 0.80 0.79 0.86 0.86 1.10 0.82
0.87 1.18 1.81 1.99 3.15 PVC11 5.11
TMC2100A118 TMC2100NB118 TMC2100SS118 - 1” 0.98 0.79 0.98 0.98 1.10 0.95
TMC2100A137 TMC2100NB137 TMC2100SS137 1” - 0.98 0.94 1.08 1.08 1.28 1.04
1.02 1.37 2.05 2.26 3.55 PVC15 6.70
TMC2125A137 TMC2125NB137 TMC2125SS137 - 1 ¼” 1.01 0.94 1.18 1.18 1.28 1.14
TMC2125A162 TMC2125NB162 TMC2125SS162 1 ¼” - 1.01 1.22 1.35 1.35 1.50 1.31
1.30 1.62 2.36 2.60 3.59 PVC18 8.82
TMC2150A162 TMC2150NB162 TMC2150SS162 - 1 ½” 1.03 1.22 1.42 1.42 1.50 1.38
TMC2125A190 TMC2125NB190 TMC2125SS190 1 ¼” - 1.01 - - 1.51 1.72 1.37
1.57 1.90 2.56 2.82 3.59 PVC37 9.45
TMC2150A190 TMC2150NB190 TMC2150SS190 - 1 ½” 1.03 - - 1.51 1.72 1.54
TMC2150A200 TMC2150NB200 TMC2150SS200 1 ½” - 1.03 1.57 1.70 1.70 1.88 1.61
1.65 2.00 2.75 3.03 3.76 PVC21 11.06
TMC2200A200 TMC2200NB200 TMC2200SS200 - 2” 1.06 1.57 1.70 1.70 1.88 1.65
TMC2150A233 TMC2150NB233 TMC2150SS233 - 1 ½” 1.03 - - 1.81 2.21 1.61
2.95 3.25 PVC23
TMC2200A233 TMC2200NB233 TMC2200SS233 2” - 1.06 - - 1.81 2.21 1.90 2.33 2.03 3.97 12.77
TMC2250A233 TMC2250NB233 TMC2250SS233 - 2 ½” 1.57 - - 1.81 2.21 2.03 3.54 3.89 PVC28
TMC2200A272 TMC2200NB272 TMC2200SS272 - 2” 1.06 2.14 2.46 2.17 2.61 2.07
3.54 3.89 PVC28
TMC2250A272 TMC2250NB272 TMC2250SS272 2 ½” - 1.57 2.14 2.46 2.46 2.61 2.27 2.72 2.40 4.10 24.69
TMC2300A272 TMC2300NB272 TMC2300SS272 - 3” 1.63 2.14 2.46 2.46 2.61 2.40 4.33 4.76 PVC31
TMC2300A325 TMC2300NB325 TMC2300SS325 3” - 1.63 2.49 2.78 2.78 2.97 2.72
2.62 3.25 4.33 4.76 4.67 PVC31 42.68
TMC2350A325 TMC2350NB325 TMC2350SS325 - 3 ½” 1.69 2.49 2.78 2.78 2.97 2.72
TMC2350A376 TMC2350NB376 TMC2350SS376 3 ½” - 1.69 2.95 3.45 3.45 3.54 3.38
3.16 3.76 4.84 5.32 4.95 LSF33 53.44
TMC2400A376 TMC2400NB376 TMC2400SS376 - 4” 1.73 2.95 3.45 3.45 3.54 3.38
TMC2400A425 TMC2400NB425 TMC2400SS425 4” - 1.73 - - 3.56 3.94 3.70 4.25 3.59 5.23 5.75 5.16 LSF34 59.19
Order code example: TMC2050A075 - “TMC2” (Type Gland) - “050” (½” NPT Thread) - ‘A’ (Material Aluminum) - “075”(Max Cable Diameter 0.75”)