Voltage Transducer LV 100-2000/SP5 VPN

= 2000 V
For the electronic measurement of voltages: DC, AC, pulsed...,
with galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).

Electrical data
Features
VPN Primary nominal voltage rms 2000 V
●● Closed loop (compensated)
VPM Primary voltage, measuring range 0 .. ± 3000 V
voltage transducer using Hall
IPN Primary nominal current rms 5 mA
effect
R M Measuring resistance RM min RM max
●● Isolated plastic case recognized
with ± 15 V @ ± 2000 V max 0 200 Ω according to UL 94-V0
@ ± 3000 V max 0 70 Ω ●● Primary resistor R1 incorporated
with ± 24 V @ ± 2000 V max 60 360 Ω within the housing.
@ ± 3000 V max 60 150 Ω
Special features
ISN Secondary nominal current rms 50 mA
K N Conversion ratio 2000 V : 50 mA ●● VC = ± 15 .. 24 (± 5 %) V
VC Supply voltage (± 5 %) ± 15 .. 24 V ●● Vd = 9 kV
IC Current consumption (± 1 mA) < 37(@ ± 24 V) + IS mA ●● TA = - 25°C .. + 70°C.

Accuracy - Dynamic performance data Advantages

XG Overall accuracy @ VPN, TA = 25°C ± 0.9 % ●● Excellent accuracy


εL Linearity error < 0.1 % ●● Very good linearity
●● Low temperature drift
Typ Max
●● Optimized response time
IO Offset current @ IP = 0, TA = 25°C ± 0.2 mA
●● Wide frequency bandwidth
IOT Temperature variation of IO - 25°C .. + 70°C ± 0.4 ± 0.6 mA
●● No insertion losses
tr
t
Response
Resp
m
o9
io
n
%
0
1)
Isteoefsp
t 100. 5.0
time to 90
µs
% of VPN step 150 µs ●● High immunity to external
r PN
interference.
General data Applications
TA Ambient operating temperature - 25 .. + 70 °C ●● Single or three phase inverter
TS Ambient storage temperature - 40 .. + 85 °C ●● Propulsion and braking chopper
NP Turns ratio 20000 : 2000 ●● Propulsion converter
P Total primary power loss 10 W ●● Auxiliary converter
R 1 Primary resistance @ TA = 25°C 400 kΩ ●● Battery charger.
RS Secondary coil resistance @ TA = 70°C 55 Ω
m Mass 790 g Application Domain
Standards EN 50155: 1995
●● Traction.

Note: Standard IEC 61000-4-6 with criteria A < 20%

Page 1/3

110404/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com
Voltage Transducer LV 100-2000/SP5

Isolation characteristics

Vd Rms voltage for AC isolation test, 50 Hz, 1 min 9 kV


Min
dCp Creepage distance 55.12 mm
dCI Clearance distance 27.9 mm
CTI Comparative Tracking Index (group I) 600

Safety

This transducer must be used in electric/electronic equipment with respect


to applicable standards and safety requirements in accordance with the
manufacturer’s operating instructions.

Caution, risk of electrical shock

When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.

Page 2/3

110404/7 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice. www.lem.com
Dimensions LV 100-2000/SP5 (in mm)

Connection

Mechanical characteristics Remarks


●● General tolerance ± 0.3 mm ●● IS is positive when VP is applied on terminal + HT.
●● Transducer fastening 2 holes Ø 6.5 mm, ●● The primary circuit of the transducer must be linked to the
2 x M6 steel screws connections where the voltage has to be measured.
Recommended fastening torque 5 Nm
●● Connection of primary M5 threaded studs
●● Connection of secondary Faston 6.3 x 0.8 mm
●● Connection to the ground M5 threaded stud
Recommended fastening torque 2.2 Nm

Page 3/3