Osram Sylvania
Osram Sylvania
Osram Sylvania
com
TABLE OF CONTENTS
TABLE OF CONTENTS
Innovation Distinctions and Awards Illuminating Engineering Society of North America (IESNA) Progress Report Environmental Plan Lead-Free Manufacturing Lamp Recycling Buy American Energy and the Cost of Lighting Warranties Glossary of Terms Linear Fluorescent Compact Fluorescent High Intensity Discharge Ballast Controls i iv v vii ix x xi xii xiii xix 1 49 71 113 175
Important Notice
The data and suggested applications contained in this catalog, as well as any additional information our representatives may be able to furnish, are for general information only and are not intended and should not be taken as representations or warranties as to the suitability of a lamp for any particular application or use in any particular equipment, nor are our representatives authorized to make any such representations or give any such warranties. Applications and conditions of use are many and varied and beyond our control. We do not have the same degree of knowledge that the purchaser has with respect to the design of his equipment and the conditions of its use. Therefore, it is up to the purchaser to make his own determination as to the suitability of a lamp for his intended application or use and to assume responsibility for that determination. OSRAM SYLVANIA claims to supply the best possible products at all times. For this reason, OSRAM SYLVANIA reserves the right to make changes in its products when it believes such changes will improve its products. The specifications and information shown in this catalog are believed to be accurate. Although OSRAM SYLVANIA believes this information to be correct, no warranty is made or implied as to the accuracy of this information and OSRAM SYLVANIA does not accept or assume responsibility of liability for errors, changes, omissions or for harm resulting therefrom. In accordance with our established policy to consistently improve our products, the specifications contained herein are subject to change without notice. The OSRAM SYLVANIA Test and Measurement Laboratory is a participant in the Energy Efficient Lighting (EEL) Program of the National Voluntary Laboratory Accreditation Program (NVLAP-NIST) and is accredited for testing of lighting products according to the guidelines for the EEL Program. OSRAM SYLVANIA lamp and ballast measurements are conducted under laboratory conditions utilizing American National Standards Institute (ANSI), Canadian Standards Association (CSA), Commission Internationale de lEclairage (CIE) and Illuminating Engineering Society of North America (IESNA) standards and practices. The OSRAM SYLVANIA Electronic Component and Systems Development Group participate in the Underwriters Laboratories Inc. Client Test Data Program. Ballast designs are tested for conformance to Underwriters Laboratory (UL) safety standards using practices audited, assessed and approved by UL. Actual lamp and ballast performance may vary depending on application and environment (i.e. ambient temperature, input voltage, ballast type, etc.) OSRAM SYLVANIA designs and manufactures lamps and ballasts to meet American National Standard Institutes (ANSI) and/or IEC (International Electrotechnical Commission) standards of construction and performance through Total Quality Manufacturing (TQM) practices where applicable. In addition, ballasts are designed and manufactured to meet Underwriters Laboratory (UL) and Canadian Standards Association (CSA) safety standards as necessary. Ratings may change as a result of changes made to remain compliant with modified or updated standards. OSRAM SYLVANIA will release new or updated technical bulletins when appropriate. All product data presented in this catalog supersedes all data published before 2/1/11. Many OSRAM SYLVANIA products listed in this catalog qualify under the North American Free Trade Agreement (NAFTA) as manufactured in Canada, the United States of America or Mexico.
ii
www.sylvania.com
iii
2010
IE S
R e p o r t
PROGRESS
ECTIO
N
EL
2010 LIgHTFAIR Innovation Awards Building Operating Management 2011 Top Products Award
2011 ADEX Awards QUICKTRONIC POWERSENSE Smart Controls LEDr A-line ULTRA LEDr PAR30LN Dimmable Lamps D6 Area Light LEDr Kit
iv
2010
Each year, The Progress Committee of the Illuminating Engineering
IE
R e p o r t
PROGRESS
ECTIO
N
Society of North America (IESNA) solicits the lighting industry for product submissions. If accepted, these submissions are featured in the committees Progress Report, which is published in the IESNAs publication, Lighting Design & Application. The mandate of the Progress Committee is to keep in touch with developments in the art and science of lighting throughout the world and prepare a yearly review of achievements for the Illuminating Engineering Society of North America. Submissions are organized into one of seven categories: light source, accessory, luminaire, research, application, publication and design tool. They are evaluated for their design, engineering characteristics, installation features and overall uniqueness. The 30-member committee of industry experts votes on up to 200 product submissions annually.
EL
Over the years, many SYLVANIA and OSRAM branded products have been accepted for the Progress Report. An itemized list of our lamps and ballasts are listed in the tables that follow along with their significant features. For detailed descriptions and specifications, please visit www.mySYLVANIA.com.
OSRAM SYLVANIA TRADITIONAL LIGHTING SUBMISSIONS ACCEPTED BY THE IESNA PROGRESS COMMITTEE
PENTRON HO Seamless T5HO fluorescent lamps PENTRON HO XL ECOLOGIC 54 Watt fluorescent lamps
PENTRON HO SUPERSAVER ECOLOGIC 47 Watt fluorescent lamps PENTRON HO ECOLOGIC SUPERSAVER lamp fluorescent lamp family DULUX T/E SUPERSAVER ECOLOGIC compact fluorescent lamps DULUX D SUPERSAVER ECOLOGIC compact fluorescent lamps OCTRON T8, PENTRON T5, PENTRON T5HO and T12 ECOLOGIC fluorescent lamp and ballast system ICETRON induction lamp and ballast system extension OCTRON 800 XP XL T8 lamps METALARC POWERBALL Ceramic 15W TF and QUICKTRONIC Super Mini lamp and ballast system METALARC POWERBALL Ceramic 200W lamp and ballast system METALARC POWERBALL Ceramic single-ended tubular metal halide lamps LUMALUX PLUS ECOLOGIC high pressure sodium lamps QUICKTRONIC High Efficiency (QHE) DALI dimming ballasts QUICKTRONIC High Efficiency (QHE) MH electronic metal halide dimming ballasts QUICKTRONIC High Efficiency (QHE) PROStart T5HO systems
*Based on 2010 IESNA Progress Committee Review
vi
1 Longer lamp life The longer life of our lamps reduces the number of lamps needed for a specific application, lowering the demand for raw materials. More importantly, it significantly lowers maintenance and recycling costs, and reduces the total amount of mercury and lead used in an application.
Reduced use of hazardous materials Lowering the use of hazardous materials is paramount at OSRAM SYLVANIA. To date, we have reduced mercury use by over 90% in our fluorescent lamps, and we continue to lower mercury levels in lamps while maintaining quality and performance. Our micro-mini CFL has less than 1.5 mg of mercury in it, the lowest of any screw-based CFL on the market. In addition, we are completely eliminating lead from nearly all HID (high intensity discharge) and USA manufactured fluorescent lamps. Our ECOLOgIC products pass the US EPAs Toxicity Characteristic Leaching Procedure (TCLP) test for hazardous waste determination. We offer nearly 1,000 ECOLOgIC products more than any other manufacturer. In addition, all applicable SYLVANIA lamps are compliant with the California RoHS regulations to restrict the use of hazardous substances.
3 Lamps with higher efficacy Our products make it possible for you to light to recommended levels using fewer lamps and possibly fewer fixtures. Higher LPW (Lumens Per Watt) also means less energy usage and a reduction of power plant emissions.
5 Lamp Recycling Fluorescent and HID lamps contain small amounts of mercury. Recycling is the most responsible way to dispose of these products keeping mercury and lead out of the waste stream. We offer turnkey recycling solutions through SYLVANIA Lighting Services (SLS). No other service company in the United States sends more lamps to be recycled than SLS.
More than mercury Mercury is a fundamental component in fluorescent lamps. It is needed to produce light and to ensure that a fluorescent lamp will achieve excellent lumen maintenance throughout its potentially long average rated life. At the same time, there are known environmental consequences of mercury. For this reason, it has been the goal of OSRAM SYLVANIA to reduce the use of mercury in fluorescent and HID lamps without sacrificing the performance requirements of high efficacy and extended lamp life. In addition, we have always recommended lamp recycling for all mercury-containing lamps, regardless of whether they pass associated tests classifying them as non-hazardous waste. Mercury is just one criterion to consider when selecting a fluorescent lighting system. Other factors contribute to the overall environmental impact including energy consumption, efficacy and lamp life. More efficient fluorescent systems that incorporate energy-saving lamp types and high efficiency electronic ballasts such as OCTRON XP lamps and QUICKTRONIC QHE ballasts will ultimately contribute less mercury and CO2 over their lifetime through reduced energy demand at the power plant. Additionally, longer-life lamps extend lamp replacement cycles, illustrated in the chart below. A fluorescent lamp containing the lowest amount of mercury is not always the most environmentally preferable solution. Energysaving, higher-performance and longer-life fluorescent systems will ultimately prevail as a more environmentally sound choice. For more information about the OSRAM SYLVANIA commitment to environmental sustainability, or about any of our energysaving and environmentally preferable lighting solutions, please visit www.sylvania.com/sustainability.
Energy efficiency and controllability of systems Energy efficient systems with lighting controls help avoid excessive greenhouse gas emissions. In the US, 50% of our electricity comes from coal-burning power plants. Another 30% comes from power plants burning other fossil fuels. Burning fossil fuels results in emissions of CO2, methane and nitrous oxide, as well as mercury emissions, from power plants. Lighting accounts for 30% of a commercial buildings electricity load. When we can reduce our electricity demand, the attributable greenhouse gas emissions are avoided.
Fluorescent System Performance Comparisons Help You Choose the Solution That is Right For You
Lamp Type Competitive 700 Series T8 Competitive 800 Series T8 OCTRON 700XP/ECO OCTRON 800XP/ECO3 OCTRON 800XPS/ECO3 OCTRON 800XP/SS/ECO3 OCTRON 800XP/SS/ECO3 OCTRON 800XP/SS/XL/ECO3 Lamp Wattage 32 32 32 32 32 28 25 28 Mercury(mg) in each lamp 1.7 1.7 3.5 3.5 2.9 2.9 2.9 3.5 CA RoHS Compliant Yes Yes Yes Yes Yes Yes Yes Yes Lamp Life (hrs at 3 hrs per start) 30,000 30,000 40,000 40,000 40,000 40,000 40,000 52,000 Number of Lamp Cycles in 5-year period 2 2 1 1 1 1 1 1 Total 5-year mercury contribution (mg) 36.2 36.2 36.4 36.4 30.4 32.5 29.3 34.3 Annual CO2 emissions (lbs) 320 320 320 320 268 297 268 297
Calculations assume two-lamp configuration on QUICKTRONIC high efficiency programmed rapid start electronic ballast; annual operating hours of 4380; total mercury contribution includes power-plant emissions Cost of ownership includes energy usage, lamp recycling cost and replacement labor ($20/hr.). Initial installation and cost of product are not included Lamp replacement assumed at 70% of rated life per IESNA Recommended Practice for Lighting Maintenance
viii
www.sylvania.com
Lead-Free Manufacturing
Fluorescent manufacturing in Versailles, Kentucky
Lead-free glass Lead-free solder Lead-free lamps OCTRON T8 T12 ECOLOgIC PENTRON T5*
HID manufacturing in Manchester, New Hampshire
Lead-free glass Lead-free solder Lead-free lamps METALARC POWERBALL Ceramic ECOLOgIC METALARC and METALARC Pulse Start ECOLOgIC** LUMALUX and LUMALUX PLUS ECOLOgIC
Electronic ballast manufacturing
ix
www.sylvania.com/recycle
Lamp Recycling. Its never been more important. Its never been easier.
When it comes to creating a sustainable future, were all in it together. No company can go it alone. Thats why SYLVANIA has joined forces with VEOLIA, a leading provider of environmental services in the US to create a safe, convenient and cost-effective program to keep you in compliance with federal, state and local disposal regulations. Let us show you how easy it is to make a difference in the world. For more information, call 1-800-LIGHTBULB or visit www.sylvania.com/recycle.
BUY AMERICAN
Looking for the best way to invest stimulus funds? Buy American compliant solutions from SYLVANIA can light the way.
The American Recovery and Reinvestment Act (ARRA) contains a Buy American provision that requires many of your current lighting projects use materials manufactured in the United States. Over two-thirds of all SYLVANIA products sold in NAFTA are made in the USA. SYLVANIA operates 17 manufacturing plants, 11 R&D labs and an equipment assembly facility right here in the USA. As regulations go, this is a win-win for your business. Not only do you receive federal funding to help stimulate your business, you get to discover a world of money saving opportunities here at home. We do more than make it easy to comply with ARRA. The savings generated from SYLVANIA energy-efficient lighting systems will save you money today and in the years to come. This results in savings you can invest and use to stimulate your business even more.
The US Department of Energy (DOE) has granted a Buy American categorical waiver under Section 1605 (Buy American) of the ARRA Act of 2009 for the use of fluorescent electronic ballasts. However, not included under the waiver are electronic dimming ballasts for fluorescent lamps that are capable of operating the lamps below 50% of their rated system light output; screw-base and pin-base compact fluorescent lamps (CFL) (10 inches or less) for use in stimulus projects that are funded by the DOEs Office of Energy Efficiency and Renewal Energy. Many of the SYLVANIA QUICKTRONIC electronic ballasts and DULUX compact fluorescent pin-base products meet these requirements. For more information, please visit www.sylvania.com/Energy/stimulus.
xi
COST OF LIgHTINg
As Figure 1 shows, the material cost of a lighting system: bulbs, ballasts and wiring, is small in relation to the cost of the energy to light it.
Energy-efficient systems
An important direction in lighting technology is the move toward systems. OSRAM SYLVANIA started the trend with the system solution, a family of optimally balanced energy-saving lamps and electronic ballast combinations. By bringing lamp and ballast development under an integrated system concept, we have been able to design innovative SYLVANIA lighting systems that optimize energy savings without sacrificing other elements of performance. OSRAM SYLVANIA has the competitive advantage, with years of experience in designing, developing and supporting integrated systems both in ballasts and lamps. Our global network of design and manufacturing brings ballast and lamp knowledge together to produce innovative, cost-effective, energy saving systems.
xii
www.sylvania.com
The
Its the simple way to make sure youre completely covered. Just call 1-800-LIgHTBULB.
QUICK 60+
Simply peace of mind When you specify SYLVANIA electronic ballasts and lamps, your installation will enjoy the highest available levels of performance, and you will enjoy the added benefit of peace of mind. If there is an issue, youll never need to worry about whether its the lamp or its the ballast, and you wont get caught in the middle of solving the problem (we may argue with ourselves, but you wont have to!). All it takes is a phone call and you can get back to business. The bottom line is these are our products, and we stand behind them as no one else can. Simply better service Only QUICK 60+ offers you a choice of three service options to resolve warranty claims for ballasts, including our unique Fixtureside Assistance program from our own nationwide service organization, SYLVANIA Lighting Services. At our discretion, we will dispatch a trained technician to make a service call to resolve any issues with our products. Our people taking care of our products ensure that you get the level of expert service you deserve. Of course, OSRAM SYLVANIA can also coordinate ballast replacement with an independent service provider, or you can manage the replacement yourself and we will determine labor reimbursement costs. OSRAM SYLVANIA will determine which option best suits your needs to make sure youre covered. For lamp replacements, OSRAM SYLVANIA will send lamps to your facility (NO LABOR FOR LAMPS).
System Warranty
Simply better coverage QUICK 60+ is the industrys original and most comprehensive system warranty, providing coverage for QUICKTRONIC ballasts and the SYLVANIA lamps they power. As the originator of the system solution, we have unparalleled lamp and ballast technology within one company that enables us to produce systems that perform better and are more reliable. Of course we design our ballasts and lamps to be compatible with other manufacturers products and back their operation accordingly, but our systems approach allows us to back our systems with a warranty that simply gives you better coverage. It starts with the ballast. When you purchase any QUICKTRONIC ballast, its warranted for a period of up to 60 months. Then, when you add SYLVANIA lamps, you benefit from additional coverage for those lamps; thats the PLUS. More combinations and wider applications provide the broadest range of coverage available in the industry. Another benefit comes each time you group relamp, as the lamp portion of the warranty will extend for an additional term. In short, if you have SYLVANIA ballasts and lamps, youre covered its that simple.
The QUICK 60+ warranty is simple to put to work. If you have SYLVANIA electronic ballasts and lamps youre covered. Just call 1-800-LIGHTBULB (1-800-544-4828) and request warranty service. Any installation of QUICKTRONIC ballasts and SYLVANIA brand lamps is covered by QUICK 60+ for periods defined in the warranty and by the date codes incorporated on all of our products. As an added value, by simply registering the installation, all warranty periods will be defined by the actual date of installation providing complete assurance that youll receive the coverage you deserve. If theres ever a problem, its not a problem you wont have to look up old records and worry about whos responsible. Its that simple.
xiii
Simple for contractors QUICKTRONIC ballasts and SYLVANIA lamps allows a contractor to provide an added value to their customers. Once the system is installed, the contractor can utilize the strengths and services of the nationwide SYLVANIA organization to assist in standing behind the project if the need arises. Added assurance its that simple.
Simple for fixture manufacturers Any lighting manufacturer that installs QUICKTRONIC ballasts in their fixtures can provide their customers with a system warranty once SYLVANIA lamps are installed. Whether the lamps are installed in the factory, or they arrive through distribution, the system is covered. In effect, OEMs can provide customers with a great deal of added value by installing SYLVANIA ballasts and lamps its that simple. Simple for lighting distributors Lighting system upgrades and retrofit installations are an important part of any electrical distributors business. QUICK 60+ allows a distributor to offer customers a comprehensive system warranty in addition to their other value added services. And since the lamp portion of QUICK 60+ renews when an installation is group relamped, distributors can offer added value to future sales of SYLVANIA brand lamps. Peace of mind today and tomorrow its that simple.
Simple for end users Todays users of lighting systems demand better performance higher lumen output, lower energy usage, better color characteristics and more responsive control capabilities all with worry-free operation. OSRAM SYLVANIA has the resources in both lamp and ballast technology to deliver the performance, while QUICK 60+ provides the industrys most comprehensive and worry-free system warranty. End users enjoy a lighting system that is high performance without being high risk its that simple.
See www.sylvania.com or www.mysylvania.com for QUICK 60+ Lamp and Ballast Limited Warranty details.
xiv
QUICK 60+
Limited Warranty
If lamps fail to operate for the warranty period, OSRAM SYLVANIA will provide a free replacement lamp (but no labor allowance). If a QUICKTRONIC ballast fails to operate within the warranty period, OSRAM SYLVANIA will provide a free replacement ballast and labor allowance in accordance with the Labor Options set forth below.
Ballast Warranty Period8 60 mos. 60 mos. 60 mos. 36/60 mos.@<90/70C 60 mos. 60 mos. 36/60 mos.@<90/70C 60 mos. 60 mos. 60 mos. 36/60 mos.@<90/70C 60 mos. 60 mos. 60 mos. 60 mos. 36/60 mos. 36/60 mos. 24 mos. 60 mos. Lamp Warranty Period* 30 mos. 36 mos. 60 mos. 36 mos. 30 mos. 24 mos. 30 mos. 24 mos. 36 mos. 60 mos. 36 mos. 60 mos. 60 mos. 24 mos. 24 mos. 6 mos. 12 mos. 6 mos. N/A
T81 T81 T81 T8 High Ambient1,9 59 59 86/T8HO High Ambient1 T5, T5/HO1 54T5/HO1
QUICKTRONIC 54T5HO High Ambient1 QUICKTRONIC QUICKTRONIC QUICKTRONIC QUICKTRONIC QUICKTRONIC QUICKTRONIC QUICKTRONIC ICE1,5 54PHO & DL40 CF1 MH7 MH7 FM 96IS/96HO & 40T12
Lamp OCTRON Family OCTRON XPS, XP & XP/SS2,3 OCTRON XP/XL & XP/XL/SS Family OCTRON XP, XP/SS2,3 OCTRON FO96/XP, FO96/XP/SS OCTRON FO96 OCTRON FO96HO PENTRON Family10 PENTRON FP54/HO, FP54/C/HO, PF54/HO/SS PENTRON HO/XL PENTRON FP54/HO, FP54/C/HO, FP54/HO/SS PENTRON HO/XL ICETRON DULUX FT55DL, FT40DL & FT40DL/SS Family DULUX D/E, T/E, T/E/IN, T/E/IN/SS T/E/C METALARC Family6 (7K-12K hrs. avg. rated life) METALARC Family6 (15K-20K hrs. avg. rated life) FM N/A
*Note: Fluorescent lamp warranty periods are based on a 3 hour minimum cycle, unless otherwise noted, with a maximum of 4000 hours per year. Other operating cycles may affect warranty period. Lamp warranty can renew when installation is group relamped, contact OSRAM SYLVANIA for details. 1 Occupancy sensor application, 10 minute/start minimum, allowed with QUICKTRONIC PROStart and with QUICKTRONIC ICE ballasts. 2 OCTRON SUPERSAVER bi-pin lamps operate on all QUICKTRONIC T8 electronic ballast (except QTP DALI models.) 3 QUICKTRONIC, Professional Series and High Efciency Series including all IS, PS & DIM models where applicable. 4 Labor options must be pre-approved by OSRAM SYLVANIA. Any labor option or cost that is not pre-approved will not be eligible for reimbursement. 5 ICETRON Lamp Warranty Period allows up to 8760 hours per year (continuous operation). 6 Contact OSRAM SYLVANIA for detailed specications of METALARC lamps. 7 QUICKTRONIC MH ballasts warranty is 36 or 60 months, depending on maximum case temperature. Refer to product specications for details. Electronic HID system warranty period is based on a minimum cycle of 10hr/start up to a maximum operation of 6,000 hours/year. 8 Maximum Case Temp. <70C, for normal environmental operating conditions (40C max. ambient) unless noted. Refer to product specications for details. 9 QUICKTRONIC T8 High Ambient (HT) Series. 10 PENTRON 14, 21, 28 and 35W and PENTRON HO 24, 39 and 80W.
TERMS AND CONDITIONS SYLVANIA lamps and QUICKTRONIC ballasts must be installed together as a system and be installed and operated under suitable environmental conditions and in accordance with the latest National Electrical Code, Underwriters Laboratory Bulletins, and ANSI Specications. This warranty will not apply in the event of conditions demonstrating abnormal use or stress, such as operating temperatures in excess of maximum rated temperatures, under/over voltage conditions, excessive switching cycles (see above Note #1) or operating hours, dirty or cracked sockets or improper lamp or ballast installation. Replacement of SYLVANIA lamps with lamps of other manufacturers will void the lamp portion of this warranty. Replacement of the QUICKTRONIC ballast with any other ballast will void the entire warranty. WARRANTY ACTIVATION / SERVICE CLAIMS The QUICK 60+ warranty is automatically activated after OSRAM SYLVANIA receives a completed QUICK 60+ warranty registration form within 30 days after installation. An acknowledgment will be sent for each registration along with a reference number for future correspondence. Service claims can be made by contacting 1-800-654-0089 to initiate the process for problem resolution. LABOR OPTIONS (Ballast only and ICETRON lamps only) No labor allowance is made for any lamp replacement except ICETRON, during the warranty period. OSRAM SYLVANIA provides for several labor options for service under the QUICK 60+ warranty program. 1. OSRAM SYLVANIA will provide full service coverage through SYLVANIA LIGHTING SERVICES at no cost to the user of the ballast, or
2. OSRAM SYLVANIA will contact a service provider and coordinate replacement at no cost to the user of the ballast, or 3. OSRAM SYLVANIA will reimburse the purchaser reasonable, customary and necessary labor charges required to install the ballast replacement. 4. Labor options must be pre-approved by OSRAM SYLVANIA. Any labor option or cost that is not pre-approved will not be eligible for reimbursement. RETURN OF DEFECTIVE PRODUCT After contacting OSRAM SYLVANIA and receiving a RETURN MATERIAL AUTHORIZATION NUMBER, the user shall promptly return the product at the users expense to OSRAM SYLVANIA after receiving instructions as to if, when and where to ship product. Failure to follow this procedure shall void this warranty. REPLACEMENT OF PRODUCT, LIMITS OF LIABILITY The foregoing shall constitute the sole and exclusive remedy of the purchaser and the sole and exclusive liability of OSRAM SYLVANIA. NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE OR IS TO BE IMPLIED. OSRAM SYLVANIA will not, under any circumstance, whether as a result of breach of contract or warranty, tort or otherwise, be liable for any incidental, special or consequential damages, including lost prots or revenues or any other costs or damages. OSRAM SYLVANIA reserves the right to examine all failed lamps and/or ballasts and reserves the right to be the sole judge as to whether any lamps and/or ballasts are defective and covered under this warranty.
QUESTIONS?
Please call customer service at 1-800-654-0089 or contact your local OSRAM SYLVANIA representative.
xv
xvi
*Subject to and limited by the lamp warranty period limitations set forth above.
LABOR OPTIONS
No labor allowance is made for lamp or ballast replacement.
FURTHER CONDITIONS
1. Warranty periods based on a minimum 4,000 hours/year to a maximum 6,000 hours/year operation (minimum 10hr/start for lamp). 2. The lighting system must operate the lamp within current ANSI Specications. 3. OSRAM SYLVANIA reserves the right to examine all failed lamps to verify cause of failure and shall be the sole judge as to whether the lamps are in fact defective. 4. System warranty valid only for installations of 50 or more lamps and ballasts. Contact OSRAM SYLVANIA for further details. 5. Check with OSRAM SYLVANIA when using occupancy sensors or dimming, as some situations may void the warranty.
QUESTIONS?
Please call customer service at 1-800-654-0089 or contact your local OSRAM SYLVANIA representative.
xvii
MAGNETIC BALLAST
Limited Warranty
Magnetic Ballast Type Fluorescent Magnetic High Intensity Discharge (HID) Magnetic Magnetic Sign
*Note Warranty periods are based on typical 4000 hr/12 months operation; longer operating cycles may limit warranty period. Contact OSRAM SYLVANIA for details.
LABOR OPTIONS
No labor allowance is made for any lamp replacement during the warranty period. OSRAM SYLVANIA shall correct any defects by replacing or repairing, at OSRAM SYLVANIAs option, any ballast determined to be defective under the terms of this warranty. Note: Labor costs are not reimbursed by OSRAM SYLVANIA.
QUESTIONS?
Please call customer service at 1-800-654-0089 or contact your local OSRAM SYLVANIA representative.
xviii
gLOSSARY
Ballast Life OSRAM SYLVANIA ballasts are designed to have an average life expectancy of 60,000 hours. To maximize life, ambient temperature should be kept as low as possible. It is also important to maintain effective dissipation of heat using the lighting fixture as a heat sink for the ballast enclosure. Ballast Losses Power consumed by a ballast
that dissipates as heat instead of being converted into light. Electronic ballasts operate more efficiently than magnetic or hybrid ballasts. A typical ballast loss for a standard two lamp energy saving magnetic ballast is 12 watts, where an electronic equivalent would only be 7 watts.
intensity of light produced at the center of a reflector lamp beam, expressed in candelas. consideration of its dominant wavelength and purity. Rendering Index (CRI) measures the effect a light source has on the perceived color of objects and surfaces. High CRI light makes virtually all colors look natural and vibrant. Low CRI causes some colors to appear washed out or even to take on a completely different hue.
Chromaticity The aspect of color that includes Color Rendering Index (CRI) The Color
Ballast A device used with an electric discharge lamp to obtain the necessary circuit conditions (voltage, current and waveform) for starting and operating; all fluorescent and HID light sources require a ballast for proper operation. Dimming ballasts are special ballasts which, when used together with a dimmer, will vary the light output of a lamp. OSRAM Display/Optic discharge lamps are either designed for AC operation (sine wave and/or square wave with recommended operational frequencies below 1KHz) or DC operation (current regulated or power regulated). Please see OSRAM lamp specifications for correct ballast or electronic control gear selection. Ballast Basics Ballasts have two primary functions: 1) start the lamp and 2) control operation of the lamp once it has started. High frequency electronic ballasts operate lamps more efficiently and eliminate the hum and visible flicker normally associated with standard magnetic ballasts. Electronic ballasts also typically have better power quality than magnetic ballasts. output (ballast factor) divided by input power (watts). Used to measure the level of efficiency of similar ballast models. For example, the OSRAM SYLVANIA QTP2X32T8/UNV ISN which has ballast factor of 0.88 and input watts of 59 (BEF = 1.49).
Ballast Types There are three types of lighting ballasts: 1) Magnetic: an inefficient device that uses a core and coil assembly transformer to perform the minimum functions required to start and operate the lamp; 2) Hybrid or low frequency electronic: essentially a magnetic ballast with a few electronic components that switch off voltage to the lamp coil once the lamp has started. A minimal increase in efficiency is obtained via more expensive magnetic core material and the absence of power to the lamp coils during operation; 3) High frequency electronic: a ballast that operates lamps at frequencies above 20,000 Hz. Maximum efficiency is obtained through the use of electronic circuitry and optimum lamp operating characteristics. Base The lamp base mechanically holds the lamp in place in the application. The lamp base directly or indirectly (via a cable or lead-in wires) conducts electricity from the circuit to the lamp and can be designed to dissipate heat. Lamp bases should be operated within specified temperature ranges. Beam Angle The angle between the two
directions for which the intensity (candlepower) is 50% of the maximum intensity as measured in a plane through the nominal beam centerline (center beam candlepower).
Color Temperature (CT) Color temperature, which is measured in Kelvin (K), indicates whether a lamp has a warm, midrange or cool color appearance. Warm light sources have a low color temperature (2000-3000K) and feature more light in the red/orange/yellow range. Light with a higher color temperature (>5000K) features more blue light and is referred to as cool. Compact Fluorescent Lamps Compact
fluorescent lamps employ small diameter tubes that are bent so they begin and end in a single base. This allows them to be produced in a wide variety of configurations, greatly extending the applications for fluorescent lighting. specification of the color appearance of a lamp, relating its color to that of a reference source, black body radiator, heated to a particular temperature, measured in Kelvin (K); CCT generally measures the warmth or coolness of light source appearance. electricity, expressed in amperes (A).
Current A measure of the rate of flow of Description (See Ordering Abbreviation.) Design Amperes The approximate current which the lamp will draw at design volts. Directional Lighting Illumination on the workplane or on an object predominantly from a single direction. Display/Optic Specialty Lamps Display/Optic
specialty lamps employ a variety of technologies to meet the very precise levels of performance required by the entertainment industry, science, medical and other high-tech fields.
Beam Spread In any plane, the angle between the two directions in the plane in which the candlepower is equal to a stated percent of the maximum candlepower in the beam. Black Body (Planckian Radiator) An ideal
thermal radiator whose SPD curve is defined by its temperature in Kelvin (K) and whose color coordinates lie exactly on the Planckian curve.
Brightness (See Luminance.) Bulb Hard, soft or quartz glass enclosure, which
can contain a vacuum, elemental inert gas or metal and a means of light generation (filament or electrodes).
opposite one another for series electrical connection, mechanical mounting and heat dissipation.
compared to a reference ballast (i.e. BF of 0.90 would yield 90% of a lamps rated lumens). OSRAM SYLVANIA offers T8 systems in many ranges of light output: Low Power (LP): (0.74-0.80) BF; Normal: (0.85-1.0) BF; Medium: (~1.0) BF; and High Light Output (PLUS): (1.15-1.20) BF.
Efficacy The rate at which a lamp is able to convert power (watts) into light (lumens), expressed in lumens per watt (LPW or lm/W). See also LPW Performance. Electric Power The time rate of doing electrical work. The unit is the watt or kilowatt. Work is being done at a rate of 1W when a constant current of 1A is maintained through a resistance by an emf of 1V. Electronic Control Systems (See Ballast.)
luminous intensity (candlepower) of a light source in a specific direction; any given light source will have many different intensities, depending upon the direction considered.
Candlepower Distribution A curve that represents the variation in luminous intensity (expressed in candelas) in a plane through the light center of a lamp or luminaire; each lamp or lamp/luminaire combination has a unique set of candlepower distributions that indicate how light will be spread.
xix
gLOSSARY
EMI/RFI Electronic Ballasts contain circuits that limit electrical noise conducted onto the power line or radiated through the air, otherwise referred to as EMI/RFI. OSRAM SYLVANIA ballasts comply with FCC 47 CFR Part 18, non-consumer limits for commercial applications. Ballasts for residential application must meet consumer limits. OSRAM SYLVANIA has a complete line of QTR electronic and magnetic ballasts for residential use.
or medium which is of itself capable of doing work is said to possess energy. Energy can be expressed in foot pounds.
integer multiple of the fundamental frequency; for example, if 60 Hz is the fundamental frequency, then 120 Hz is the second harmonic and 180 Hz is the third harmonic. Some electronic devices, such as ballasts or power supplies, can cause harmonic distortion, directly affecting power quality.
Hertz (Hz) A unit of frequency equal to one cycle per second; see Frequency. High Intensity Discharge (HID) Lamps
Lamps in which an arc passing between two electrodes in a pressurized tube causes various metallic additives to vaporize and release large amounts of light. All HID lamps offer outstanding energy efficiency and service life. Metal halide lamps also offer good to excellent color rendering index (CRI).
lamp from over-voltage or over-current conditions. OSRAM requires that all Display/Optic lamps be fused in their applications to prevent lamp over-powering. Certain lamps contain their own internal fuse. Please ensure lamps in your specific application are fused with respect to their power source.
The multiplier to be used in illumination calculations to relate the initial rated output of light sources to the anticipated minimum rated output based on the relamping program to be used. (See Lumen Depreciation and Mean Lumens.)
inside a lamp bulb, that when heated electrically generates radiation in the visible, infrared and ultraviolet ranges. Tungsten material is most often used, as it has great tensile strength, is very durable and can be heated very near its melting point without evaporating rapidly. Lamp filaments are offered in a variety of designs optimized for specific applications.
Lens A glass or plastic element used in luminaires to change the direction and control the distribution of light rays. Light Radiant energy that is capable of producing a visual sensation. Light Center Length (LCL) The distance from Light Loss Factor (LLF) A factor used in
a specified reference point on a lamp base to its light center. calculating illuminance after a given period of time and under given conditions. It takes into account temperature and voltage variations, dirt accumulation on luminaire and room surfaces, lamp depreciation, maintenance procedures and atmosphere conditions. Formerly called maintenance factor.
operating lamp shortly after turn-off. Hot ignition is a high performance feature in many OSRAM SYLVANIA discharge lamp types.
expressed in lumens per unit area; 1 lumen per square foot equals 1 footcandle, while 1 lumen per square meter equals 1 lux.
Fluorescent Lamp A low pressure mercury vapor discharge light source. The electric discharge generates ultra-violet (UV) energy, which is absorbed by a phosphor and converted to visible light. Focal Distance The distance between a lamp
(light producing element) and the focal point of the reflector surrounding it. Lamp alignment can be adjusted to influence both illumination and color quality. Sometimes referred to as working distance.
Incandescent Lamp A light source using the principle of incandescence. When an electric current passes through a filament wire (usually tungsten), the heated wire glows. Filaments of standard incandescent lamps are enclosed in a vacuum or gas-filled bulb. They provide low initial cost, good color rendition and excellent optical control. Instant Start (IS) Instant start ballasts apply high voltage across the lamp with no preheating of the cathode. This is the most energy efficient starting method for fluorescent lamp ballasting. IS ballasts use 1.5 to 2 watts less per lamp than rapid start ballast. Other IS ballast benefits typically include parallel lamp circuitry, longer remote wiring distance, easier installation due to less complicated wiring and the lamps have the capability to start at temperatures down to -20F (starting temperatures may vary depending on ballast/lamp types and applications, see actual specifications for details) versus 50F for rapid start. K-Factor A measurement that quantifies the effect of non-linear equipment, such as lighting ballasts, on an electrical system. Lighting systems should be designed so that the transformer rating is sufficient for the ballast used (typically K-factor <4). All OSRAM SYLVANIA ballasts meet this specification. Lamp Manufactured light source, synonymous
with light bulb; the three broad categories of electric lamps are incandescent, fluorescent and high intensity discharge.
that an alternating current system reverses from positive to negative and back to positive, expressed in cycles per second or hertz (Hz). inherent electrical protection. Although there is no need to externally fuse the ballast, should code or regulation require one, 3 amp slow blow fuses are recommended.
rated lamp life, a ballast should start a lamp so that the time from when the lamp begins to glow to the time the lamp arc strikes should be as short as possible. OSRAM SYLVANIA instant start ballasts typically accomplish this task within 50 m/sec.
Low Temperature Starting SYLVANIA QUICKTRONIC QTP & QHE instant start and programmed start electronic ballasts have the capability to start fluorescent lamps at temperatures down to -20F as well as 0F for F40T8 & F96T8 lamps providing the following conditions are met: 1. The ballast is operated at rated nominal line voltage. The ballast case and fixture must always be grounded. The grounding helps assure safety, proper lamp starting. Install ballast in accordance with national and local electrical codes. 2. Ballast cannot be tandem/remote wired for low temperature starting applications. Please note, starting time may increase at low ambient temperatures. Enclosed fixtures are recommeded as fluorescent lamps have reduced light output at cooler ambient temperatures. (See specifications for each models starting temperature rating.) SUPERSAVER lamps start/operate >60F. (See specific product information bulletins for each models starting temperature rating.) LPW Performance Lumens Per Watt. The
number of lumens produced by a light source for each watt of electrical power supplied to the light source. Also see Efficacy.
Grounding The ballast case and fixture must always be grounded. The grounding helps assure safety, proper lamp starting and acceptable EMI/ RFI performance. Install ballast in accordance with national and local electric codes. Halogen Lamps High pressure tungsten filament
lamps containing halogen gases. The halogen gases allow the filaments to operate at higher efficacies than incandescent lamps. Halogen lamps also provide brighter, whiter light with better color characteristics, longer service life and improved energy efficiency.
ratio of peak lamp current to the RMS (root mean square) lamp current. Lamp manufacturers require a LCCF of less than 1.70 in order to achieve full lamp life.
Lamp Flicker Cyclic variation in output of a light source. High frequency electronic ballasts minimize lamp flicker. Lamp flicker from magnetic ballasts may cause eye fatigue for some people.
Lumen Maintenance (See Lumen Depreciation.) Lumens (lm) A unit of luminous flux; overall light output; quantity of light, expressed in lumens. For example, a dinner candle provides about 12 lumens and a 60-watt soft white incandescent lamp provides about 840 lumens. xx
gLOSSARY
Luminaire A light fixture; the complete lighting unit, including lamp, reflector, ballast, socket, wiring, diffuser and housing. Luminaire Efficiency The ratio of luminous flux (lumens) emitted by a luminaire to that emitted by the lamp or lamps used therein. Luminance (L) Light reflected in a particular direction; the photometric quantity most closely associated with brightness perception, measured in units of luminous intensity (candelas) per unit area (square feet or square meters). Luminance Contrast The relationship between the luminances of an object and its immediate background. Luminance Ratio The ratio between the
luminances of any two areas in the visual field.
description of the lamp, using a unique code which can be used when ordering a lamp if the Product Number is not known. An example would be: CF15EL/R30/830/MED, which translates to a 15-watt Soft White DULUX EL reflector electronic self-ballasted compact fluorescent lamp with an R30 reflector, 82CRI, 3000K color temperature and a medium screw base.
PAR Lamps Pressed aluminized reflector lamp, with the outer bulb formed from two pressed glass parts that are fused or sealed together. PAR lamps may be incandescent, halogen or HID types. Parallel vs. Series wiring configurations for
ballasts. Ballasts with parallel lamp circuitry have the benefit of companion lamps remaining lit, even if one of the lamps operated by the ballast should fail. Systems with series lamp wiring, should one lamp fail, all lamps operated on the series ballast will turn off (magnetic ballasts and many rapid start electronic types). with which an electrical device converts voltamperes to watts; devices with power factors (>0.90) are high power factor devices.
Shielding A general term to include all devices used to block, diffuse or redirect light rays, including baffles, louvers, shades, diffusers and lenses. Single-Ended Lamps having a single lamp base
or point of electrical connection.
Maximum Case Temperature All OSRAM SYLVANIA electronic ballasts have a maximum allowable case temperature. Refer to product information bulletins for specific product maximum case temperatures. Applications in which the case temperature exceeds this maximum void all warranties. Maximum Overall Length (MOL) The total length of a lamp, from top of bulb to bottom of base. Mean Lumens Lumen output of a light source
after the source has been used. Mean lumen values for fluorescent and HID lamps are typically measured at 40% of their rated lives. Most high pressure sodium and mercury lamps are measured at 50% of their rated lives. All measurements are made on ANSI reference ballasts. Mean lumens are not typically measured for incandescent and tungsten halogen lamps.
starter, which allows the lamp and filaments to be properly heated before allowing the ballast to supply the correct current flow.
1990) have defined a TCLP test to determine whether wastes are to be treated as hazardous or non-hazardous.
TCLP Test (Toxicity Characteristic Leaching Procedure) Federal EPA regulations (RCRA of
Total Harmonic Distortion (THD) A measure of the distortion of an electrical wave form. Excessive THD (defined by ANSI as greater than 32%) may cause adverse effects to the electrical system. <20% THD ballasts are fine for most applications. However, in buildings with neutral problems caused by high THD loads such as computers, printers, DC supplies, etc., the <10% THD products can help reduce the overall % of Total Harmonic Distortion. Transient Protection OSRAM SYLVANIA
ballasts meet ANSI 62.41 Category A. This helps ensure immunity to electrical disturbances such as power line transients, and temporary line voltage dropouts, surges and sags.
specific OSRAM SYLVANIA lamp. The NAED number in this catalog is labeled Product Number and should be used when ordering OSRAM SYLVANIA products. NAED is the abbreviation for National Association of Electrical Distributors.
Nanometer (nm) A unit of length equal to 10-9 Nominal Watts Wattage used to describe a
lamp. Also see Watt.
Trigger Start A circuit used to eliminate the starter and start the preheat lamp almost instantly. In this circuit each electrode is connected to a separate winding in the ballast so that the electrode is continuously heated. Tungsten Halogen Cycle A regenerative cycle of tungsten and halogen atoms, which, when incorporated into the design of halogen light sources, prevents blackening of the lamp envelope during life. Voltage (V) A measure of electrical potential,
expressed in volts (V). Voltage is the force that pushes electrical current through a conductor.
OFR Abbreviation for ozone free technology. Lamps with the designation OFR do not generate ozone during operation.
designed to be operated in certain positions, i.e., horizontal or base up.
to have certain prescribed characteristics for use in testing electric-discharge lamps and other ballasts. Reference ballasts are typically defined by ANSI.
the process of reflection. Display/Optic reflector lamps utilize ellipsoidal (converging light rays) or parabolic (collimating light rays) reflectors. Dichroic coated reflectors are designed to reflect visible light and pass through unwanted infrared wavelengths.
Watt (W) A unit of electrical power equal to 1 joule per second. Lamps are rated in watts to indicate power consumption. Also see Nominal Watts. Wavelength (l) Distance between two successive points of a periodic wave; the wavelengths of light are typically expressed in nanometers (nm), or billionths of a meter. (See Focal Distance.)
xxi
Fluorescent
TABLE OF CONTENTS
Lamp Basics Competitive Cross Reference Guide Color Temperature and Rendering Guide Lamp and Base Diagrams OCTRON Lamps OCTRON CURVALUME Lamps
2 4 6 7 8 16 19 20 21 23 24 31 34 37 42 42 43 45
OCTRON Specialty PENTRON Lamps PENTRON HO Lamps PENTRON Circline T12 Rapid Start Lamps T12 Instant Start Slimline Lamps Preheat Lamps SAFELINE Lamps GRO-LUX Lamps
Color coding system: Premium products Standard products Safety coated products Products to be discontinued 1
L I N E A R F L U O R E S C E N T
BULB
Usually straight glass tube. May also be circular or U-shaped.
PHOSPHOR
Coating inside the bulb transforms ultraviolet radiation into visible light. Color of light produced depends on composition of phosphor.
CATHODE
Hot cathodes at each end of lamp are coated with emissive materials which emit electrons. Usually made of coiled-coil or singlecoil tungsten wire.
EXHAUST TUBE
Air is exhausted through this tube during manufacture and inert gas introduced into the bulb.
BASE
Several different types used to connect the lamp to the electric circuit and to support the lamp in the lampholder.
MERCURY
A minute quantity of liquid mercury is placed in the bulb to furnish mercury vapor.
GAS
Usually argon or a mixture of inert gases at low pressure. Krypton is sometimes used.
STEM PRESS
The lead-in wires have an air tight seal here and are made of specific wire to assure about the same coefficient of expansion as the glass.
LEAD-IN WIRES
Connect to the base pins and carry the current to and from the cathodes and the mercury arc.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
Base
L I N E A R F L U O R E S C E N T
47.78 Med Bipin 47.78 Med Bipin 45.5 94 Mini Bipin Single Pin
Design wattage on reference ballast. Actual wattage dependent on ballast. Describes the shape of the bulb followed by the bulbs diameter at its widest point. The diameter value is expressed in eighths of an inch. Ex. T = Tubular, 8 = 8/8 inch = 1 inch. Please see page 7 for bulb illustrations. Please see page 7 for base illustrations. The nominal length of linear fluorescent lamps is typically measured from back of lampholder to back of lampholder. PENTRON linear lamp, CURVALUME and Circline lamps are exceptions. The nominal length given for PENTRON linear lamps is the closest familiar nominal length. CURVALUME lamps are measured from the face of the bases to the outside of the glass bend. The measurement for Circline lamps is the outside diameter. Values are in inches. Maximum overall length. The length of the lamp measured in inches. Most symbols and footnotes that apply to a specific product will appear in this space. The explanations of the symbols and footnotes are at the end of the fluorescent section. A text description of the lamp. See below for several examples and explanations of some of the codes. A text description of the lamp. Please see below for several examples and explanations of some of the codes. Correlated Color Temperature. The degree of whiteness of the light. Expressed in Kelvins (K). Please see page 6 for more information. Color Rendering Index. A numbering system for rating the relative color rendering quality of a light source compared to a standard. Please see page 6 for more information. Initial lumens are measured when the lamp has been operating for 100 hours. Mean lumens are typically measured at 40% of the rated life of the lamp. For longer life lamps such as the OCTRON XP lamps, the mean lumens are measured at the same point in time as they are measured for the standard lamps they replace. Fluorescent lamp lumens are typically measured at 25C (77F). The lamp lumens are measured at both 25C (77F) and 35C (95F) for PENTRON linear lamps.
MOL Symbols & Footnotes Ordering Abbreviation CCT CRI Initial & Mean Lumens
Hg
For weight and measurement information, please visit www.sylvania.com Specifications subject to change without notice. Symbols/Footnotes on pages 45-47
L I N E A R F L U O R E S C E N T
* Trademarks or registered trademarks of General Electric Company ** Trademarks or registered trademarks of Philips
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
L I N E A R F L U O R E S C E N T
L I N E A R F L U O R E S C E N T
For a more complete manufacturers cross reference, please see that section of this catalog or visit the electronic catalog at www.sylvania.com.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
FLUORESCENT LAMPS
The bulb shape and size of a fluorescent lamp are expressed by means of a code consisting of the letter T (which designates that the bulb is tubular in shape) followed by a number that expresses the diameter in eighths of an inch. Diameters range from T2 (14 inch) to T17 (218 inch). In nominal overall length, linear fluorescent lamps range from 6 to 96 inches. The nominal length is measured from back of lamp holder to back of lamp holder. For example, the actual overall length of the 40-watt rapid start T12 lamp with a nominal length of 48 inches is 4734 inches. The nominal length given for PENTRON linear lamps is the closest familiar nominal length. CURVALUME U-shaped fluorescent lamps are available as OCTRON T8 lamps with leg spacings of 158 inches and 6 inches and as rapid start T12 lamps with 6 spacings of 6 inches. The leg spacing is measured from the center of one leg to the center of the other leg. The overall length of the CURVALUME lamps is measured from the face of the bases to the outside of the glass bend. Circline lamps, which are circular in shape, are available as T9 lamps with outside diameters of 612, 8, 12 and 16 inches as well as PENTRON T5 lamps with outside diameters of 8.85 and 11.77 inches.
T2 MINIATURE T2 Axial Base (2/8 Diameter) PREHEAT, RAPID START Preheat T5 Miniature Bipin (5/8 diameter) PENTRON T5 Miniature Bipin (5/8 diameter) T12 Recessed Double Contact (1-1/2 diameter) HIGH OUTPUT AND VERY HIGH OUTPUT
L I N E A R F L U O R E S C E N T
ICETRON
ICETRON
BASES
For linear Preheat and Rapid Start Lamps, four electrical contacts are required, two at each end of the lamp. This is accomplished in the standard line of lamps by the use of a miniature bipin base for T5 lamps and a medium bipin for T8 and T12 lamps. The OCTRON T8 medium bipin lamps may also be operated as instant start lamps with the proper wiring and ballasts. When operating OCTRON bipin lamps with instant start ballasts, the two contacts in the lamp holder are shorted together and connected to the single circuit in the ballast. In Circline lamps, the cathodes are connected to a 4-pin base located between the junction of the two ends of the lamp. High Output (HO) and Very High Output (VHO) lamps have recessed double contact (RDC) type bases. Slimline Instant Start lamps require only two electrical contacts, one on each lamp end and have single pin bases.
SINGLE PIN
Single Pin for T6 Slimline BIPIN Miniature Bipin for T5 Preheat & PENTRON
Axial T2 Subminiature
L I N E A R F L U O R E S C E N T
Base
Notes *, *, *, *,
, , , 3,6,12,13,17,19 , , ,
3,6,12,13,17,19 , , ,
3,6,12,13,17,19 , , ,
3,6,12,13,17,19 , , ,
25
T8
48
3,6,12,13,17,19 , , ,
3,6,12,13,17,19 , , ,
3,6,12,13,17,19
Base
Notes *, *, *, *, *,
, , , 3,6,12,13,17,19 , , ,
3,12,13,17,19 , , ,
3,12,13,17,19 , , ,
3,12,13,17,19 , , ,
3,12,13,17,19
*means this bulb meets Federal minimum efficiency standards For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
L I N E A R
Notes *, *, *, *, *,
, , , 3,12,13,17,19 , ,
Base
Ordering Abbreviation FO32/830/XPS/ECO FO32/835/XPS/ECO FO32/841/XPS/ECO FO32/850/XPS/ECO FO32/865/XPS/ECO FO17/830/XPS/ECO FO17/835/XPS/ECO FO17/841/XPS/ECO FO25/830/XPS/ECO FO25/835/XPS/ECO FO25/841/XPS/ECO
CCT (K) 3000 3500 4100 5000 6500 3000 3500 4100 3000 3500 4100
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 , ,
F L U O R E S C E N T
3,12,13,17,19 ,
17
T8
24
3,12,13,17,19 , ,
3,12, 13,17,19 , ,
3,12,13,17,19 , ,
25
T8
36
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19
Base
Ordering Abbreviation FO32/25W/830/XP/SS/ECO FO32/25W/835/XP/SS/ECO FO32/25W/841/XP/SS/ECO FO32/25W/850/XP/SS/ECO FO28/830/XP/SS/ECO FO28/835/XP/SS/ECO FO28/841/XP/SS/ECO FO28/850XP/SS/ECO
CCT (K) 3000 3500 4100 5000 3000 3500 4100 5000
Notes
, , 3,6,12,13,17,19 , ,
3,6,12,13,17,19 , ,
3,6,12,13,17,19 , ,
3,6,12,13,17,19
28
T8
48
*, *, *, *,
3,6,12,13,17,19 , ,
3,6,12,13,17,19 , ,
3,6,12,13,17,19 , ,
3,6,12,13,17,19
*means this bulb meets Federal minimum efficiency standards Specifications subject to change without notice. Symbols/Footnotes on pages 45-47
L I N E A R F L U O R E S C E N T
Base
Ordering Abbreviation FO30/830/XP/SS/ECO FO30/835/XP/SS/ECO FO30/841/XP/SS/ECO FO30/850/XP/SS/ECO FO25/21W/830/XP/SS/ECO3 FO25/21W/835/XP/SS/ECO3 FO25/21W/841/XP/SS/ECO3 FO25/21W/850/XP/SS/ECO3 FO17/15W/830/XP/SS/ECO3 FO17/15W/835/XP/SS/ECO3 FO17/15W/841/XP/SS/ECO3 FO17/15W/850/XP/SS/ECO3
CCT (K) 3000 3500 4100 5000 3000 3500 4100 5000 3000 3500 4100 5000
Notes *, *, *, *,
, , , 3,6,12,13,17,19 , ,
3,6,12,13,17,19 , ,
3,6,12,13,17,19 , ,
3,6,12,13,17,19 ,3,6,
21
T8
36
36
Med Bipin
12,13,17,19 , ,3,6,
12,13,17,19 , ,3,6,
12,13,17,19 , ,3,6,
12,13,17,19 , ,3,6,
15
T8
24
24
Med Bipin
12,13,17,19 , ,3,6,
12,13,17,19 , ,3,6,
12,13,17,19 , ,3,6,
12,13,17,19
*means this bulb meets Federal minimum efficiency standards For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
10
L I N E A R
Notes *, *, *, *, *, *,
, , , 3,12,13,17,19 , ,
Base
Ordering Abbreviation FO32/827/XP/ECO FO32/830/XP/ECO FO32/835/XP/ECO FO32/841/XP/ECO FO32/850/XP/ECO FO32/865/XP/ECO FO32/SKYWHITE/XP/ECO FO17/827/XP/ECO FO17/830/XP/ECO FO17/835/XP/ECO FO17/841/XP/ECO FO17/850/XP/ECO FO17/865/XP/ECO FO25/827/XP/ECO FO25/830/XP/ECO FO25/835/XP/ECO FO25/841/XP/ECO FO25/850/XP/ECO FO25/865/XP/ECO FO40/830/XP/ECO FO40/835/XP/ECO FO40/841/XP/ECO FO40/865/XP/ECO
CCT (K) 2700 3000 3500 4100 5000 6500 8000 2700 3000 3500 4100 5000 6500 2700 3000 3500 4100 5000 6500 3000 3500 4100 6500
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 , ,
F L U O R E S C E N T
3,12,13,17,19 , ,
3,12,13,17,19 ,
3,12,13,17,19 , ,
17
T8
24
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 , ,
13,17,19 , ,
3,12,13,17,19 , ,
25
T8
36
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 , ,
40
T8
60
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19
*means this bulb meets Federal minimum efficiency standards Specifications subject to change without notice. Symbols/Footnotes on pages 45-47
11
L I N E A R F L U O R E S C E N T
Base
Notes *, *, *,
, , 3,17,19,30,33 , ,
3,17,19,30,33 , ,
3,17,19,30,33
Base
Ordering Abbreviation FO32/830/ECO FO32/835/ECO FO32/841/ECO FO32/850/ECO FO17/830/ECO FO17/835/ECO FO17/841/ECO FO25/830/ECO FO25/835/ECO FO25/841/ECO FO40/830/ECO FO40/835/ECO FO40/841/ECO
CCT (K) 3000 3500 4100 5000 3000 3500 4100 3000 3500 4100 3000 3500 4100
Notes *, *, *, *,
, , , 3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 ,
17
T8
24
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 , ,
25
T8
36
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19 , ,
40
T8
60
3,12,13,17,19 , ,
3,12,13,17,19 , ,
3,12,13,17,19
*means this bulb meets Federal minimum efficiency standards For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
12
L I N E A R
Notes *, *, *, *, *,
, , ,3, 12,13,17,19,36 , ,3,
Base
Ordering Abbreviation FO32/730/ECO FO32/735/ECO FO32/741/ECO FO32/750/ECO FO32/765/ECO FO13/735/ECO FO13/741/ECO FO17/730/ECO FO17/735/ECO FO17/741/ECO FO25/730/ECO FO25/735/ECO FO25/741/ECO FO40/730/ECO FO40/735/ECO FO40/741/ECO
CCT (K) 3000 3500 4100 5000 6500 3500 4100 3000 3500 4100 3000 3500 4100 3000 3500 4100
12,13,17,19,36 , ,3,
12,13,17,19,36 , ,3,
12,13,17,19,36 , ,3,
F L U O R E S C E N T
12,13,17,19,36 ,3,
14
T8
18
21666 21667
12,13,17,19,36 , ,3,
12,13,17,19,36 , ,3,
17
T8
24
12,13,17,19,36 , ,3,
12,13,17,19,36 , ,3,
12,13,17,19,36 , ,3,
25
T8
36
12,13,17,19,36 , ,3,
12,13,17,19,36 , ,3,
12,13,17,19,36 , ,3,
40
T8
60
12,13,17,19,36 , ,3,
12,13,17,19,36 , ,3,
12,13,17,19,36
*means this bulb meets Federal minimum efficiency standards Specifications subject to change without notice. Symbols/Footnotes on pages 45-47
13
L I N E A R F L U O R E S C E N T
Pkg Qty 24 24 24 24 24 24
CRI 85 85 81 85 85 81
Notes *, *, *, *, *, *,
, , 3,5,12,13,17 , ,
3,5,12,13,17 , ,
3,5,12,13,17 , , ,
50
T8
96
94
Single Pin
3,5,12,13,17 , , ,
3,5,12,13,17 , , ,
3,5,12,13,17
Pkg Qty 24 24 24 24 24 24
CRI 85 85 85 85 85 85
Notes *, *, *, *,
, , , 3,12,13,17 , ,
3,12,13,17 , ,
3,12,13,17 , ,
3,12,13,17 ,
44
T8
72
72
21598 21599
3,12,13,17 , ,
28
T8
48
48
3,12,13,17
Pkg Qty 24 24 24 24 24 24
CRI 82 82 82 81 85 85
Notes *, *, *, *, *, *,
, , 3,12,13,17 , ,
3,12,13,17 , ,
3,12,13,17 , ,
3,12,13,17 , ,
86
T8
96
93.91 RecessedDC
22206 22207
3,12,13,17 , ,
3,12,13,17
*means this bulb meets Federal minimum efficiency standards For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
14
L I N E A R
Notes *, *, *, *, *,
, , 3,12,13,17,36 , ,
Pkg Qty 24 24 24 24 24
CRI 75 75 75 78 78
3,12,13,17,36 , ,
3,12,13,17,36 , ,
86
T8
96
93.91 RecessedDC
22204 22205
3,12,13,17 , ,
F L U O R E S C E N T
3,12,13,17
*means this bulb meets Federal minimum efficiency standards Specifications subject to change without notice. Symbols/Footnotes on pages 45-47
15
L I N E A R F L U O R E S C E N T
Nominal Nominal Length MOL Wattage Bulb (in) (in) 29 T8 22.5 22.6
Notes *, *, *,
, ,3,12, 13,17,19,20,27 , ,3,12,
13,17,19,20,27 , ,3,12,
13,17,19,20,27 , , ,3,12,
27
T8
22.5
22.6
Med Bipin
13,17,19,20,27 , , ,3,12,
13,17,19,20,27 , , ,3,12,
13,17,19,20,27 , , ,3,12,
13,17,19,20,27
Nominal Nominal Length MOL Wattage Bulb (in) (in) 31 T8 22.5 22.6
Notes *, *, *,
, ,3, 12,13,17,19,20 , ,3,
12,13,17,19,20 , ,3,
12,13,17,19,20
*means this bulb meets Federal minimum efficiency standards For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
16
L I N E A R
Notes *, *, *, *
, , , 3, 12,13,17,19,20 , , 3,
Nominal Nominal Length MOL Wattage Bulb (in) (in) 31 T8 22.5 22.6
Ordering Abbreviation FBO31/830 FBO31/835 FBO31/841 FBO31/750 FBO16/830 FBO16/835 FBO16/841 FBO24/830 FBO24/835 FBO24/841
CCT (K) 3000 3500 4100 5000 3000 3500 4100 3000 3500 4100
12,13,17,19,20 , , 3,
12,13,17,19,20 , , 3,
12,13,17,19,20 , 3,12,
F L U O R E S C E N T
16
T8
10.5
10.6
Med Bipin
21834 21835
13,17,19,20 , , 3,12,
13,17,19,20 , , 3,12,
16
T8
10.5
10.6
13,17,19,20 , , 3,12,
24
T8
16.5
16.6
13,17,19,20 , , 3,12,
13,17,19,20 , , 3,12,
13,17,19,20
Nominal Nominal Length MOL Wattage Bulb (in) (in) 30 T8 22.5 22.6
Notes *, *, *, *, *, *,
, ,3,12, 13,17,19,20,27 , ,3,12,
13,17,19,20,27 , ,3,12,
13,17,19,20,27 , , ,3,
28
T8
22.5
22.6
Med Bipin
12,13,17,19,20,27 , , ,3,
12,13,17,19,20,27 , , ,3,
12,13,17,19,20,27
*means this bulb meets Federal minimum efficiency standards Specifications subject to change without notice. Symbols/Footnotes on pages 45-47
17
L I N E A R F L U O R E S C E N T
Nominal Nominal Length MOL Wattage Bulb (in) (in) 32 T8 22.5 22.6
Notes *, *, *, *,
, ,3, 12,13,17,19,20 , ,3,
12,13,17,19,20 , ,3,
12,13,17,19,20 , ,3,
12,13,17,19,20
Nominal Nominal Length MOL Wattage Bulb (in) (in) 32 T8 22.5 22.6
Notes *, *, *,
, ,3, 12,13,17,19,20 , ,3,
12,13,17,19,20 , ,3,
12,13,17,19,20
Nominal Nominal Length MOL Wattage Bulb (in) (in) 32 T8 22.5 22.6
Notes *, *, *, *,
, ,3, 12,13,17,19,20 , ,3,
12,13,17,19,20 , ,3,
12,13,17,19,20 , ,3,
12,13,17,19,20
*means this bulb meets Federal minimum efficiency standards For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
18
L I N E A R
Notes
, ,3, 12,13,17,19 ,3,12, 13,17,19 , ,3,12,
Base
Ordering Abbreviation FO13/865/XP/ECO FO14/950/20in FBO16/865/XP FO17/950/24in FO17/865/XP/ECO FO21/950/30in FO21/865/XP/ECO FO25/950/36in FO25/865/XP/ECO FO28/950/40in FO32/950/48in FO32/865/XP/ECO FO32/865/XP/XL/ECO3 FO40/950/60in FO40/865/XP/ECO
CCT (K) 6500 5000 6500 5000 6500 5000 6500 5000 6500 5000 5000 6500 6500 5000 6500
17.91 Med Bipin 19.78 Med Bipin 10.60 Med Bipin 23.78 Med Bipin
15
T8
20
16
T8
10.5
17
T8
24
F L U O R E S C E N T
21
T8
30
21869 21730
25
T8
36
21872 21719
28
T8
40
32
T8
48
*, *,
,3,
12,13,17,19 , , ,
40
T8
60
21873 21721
12,13,17,19
OCTRON Specialty
Life @ 3hrs/ Pkg start Qty IS 12 24000 Life @ Life @ 12hrs/ 3hrs/ start start IS PRS 30000 30000 Life @ 12hrs/ start PRS 36000 Approx Lumens Initial (Mean) CRI @25C/77F 1700 (1530)
Base
CCT (K)
Notes
, , 3,13,16, 17,19
*means this bulb meets Federal minimum efficiency standards Specifications subject to change without notice. Symbols/Footnotes on pages 45-47
19
L I N E A R F L U O R E S C E N T
Product Ordering Number Abbreviation 20948 20943 20944 FP28/830/PM/ECO FP28/835/PM/ECO FP28/841/PM/ECO
Pkg Qty 40 40 40
CRI 85 85 85
Notes
, ,3,12, 13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24
Product Ordering Number Abbreviation 20975 20868 20901 20902 22203 20990 FP28/827/ECO FP28/830/ECO FP28/835/ECO FP28/841/ECO FP28/850/ECO FP28/865/ECO FP14/827/ECO FP14/830/ECO FP14/835/ECO FP14/841/ECO FP14/865/ECO FP21/827/ECO FP21/830/ECO FP21/835/ECO FP21/841/ECO FP35/827/ECO FP35/830/ECO FP35/835/ECO FP35/841/ECO
Pkg Qty 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
CCT (K) 2700 3000 3500 4100 5000 6500 2700 3000 3500 4100 6500 2700 3000 3500 4100 2700 3000 3500 4100
CRI 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85
Notes
, ,3,12, 13,14,17,24,35 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
14
T5
24
22.2
Mini Bipin
13,14,17,24,35 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
21
T5
36
34.0
Mini Bipin
13,14,17,24,35 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
35
T5
60
57.6
Mini Bipin
13,14,17,24,35 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
20
L I N E A R
Notes
, , , 3, 12,13, 14,17,24 , , , 3,
Product Ordering Number Abbreviation 20196 20197 20198 20199 20201 FP54/830/HO/XL/ECO FP54/835/HO/XL/ECO FP54/841/HO/XL/ECO FP54/850/HO/XL/ECO FP54/865/HO/XL/ECO
Pkg Qty 40 40 40 40 40
CRI 85 85 85 85 85
12,13, 14,17,24 , , , 3,
12,13, 14,17,24 , , , 3,
12,13, 14,17,24 , , , 3,
F L U O R E S C E N T
12,13, 14,17,24
Product Ordering Number Abbreviation 21070 21071 20964 21072 FP54/50W/830/HO/SS/ECO FP54/50W/835/HO/SS/ECO FP54/50W/841/HO/SS/ECO FP54/50W/850/HO/SS/ECO FP54/47W/830/HO/SS/ECO FP54/47W/835/HO/SS/ECO FP54/47W/841/HO/SS/ECO FP54/47W/850/HO/SS/ECO FP39/35W/830/HO/SS/ECO FP39/35W/835/HO/SS/ECO FP39/35W/841/HO/SS/ECO FP24/21W/830/HO/SS/ECO FP24/21W/835/HO/SS/ECO FP24/21W/841/HO/SS/ECO
Pkg Qty 40 40 40 40 40 40 40 40 40 40 40 40 40 40
CCT (K) 3000 3500 4100 5000 3000 3500 4100 5000 3000 3500 4100 3000 3500 4100
CRI 85 85 85 85 85 85 85 85 85 85 85 85 85 85
Notes
, , , 3, 12,13, 14,17,24 , , , 3,
12,13, 14,17,24 , , , 3,
12,13, 14,17,24 , , , 3,
12,13, 14,17,24 , , , 3,
47
T5
48
45.8
Mini Bipin
12,13, 14,17,24 , , , 3,
12,13, 14,17,24 , , , 3,
12,13, 14,17,24 , , , 3,
12,13, 14,17,24 , , , 3,
35
T5
36
34
Mini Bipin
12,13, 14,17,24 , , , 3,
12,13, 14,17,24 , , , 3,
12,13, 14,17,24 , , , 3,
21
T5
24
22.2
Mini Bipin
12,13, 14,17,24 , , , 3,
12,13, 14,17,24 , , , 3,
12,13, 14,17,24
21
L I N E A R F L U O R E S C E N T
Product Ordering Number Abbreviation 20903 20904 20906 20949 20862 FP54/830/HO/ECO FP54/835/HO/ECO FP54/841/HO/ECO FP54/850/HO/ECO FP54/865/HO/ECO FP24/830/HO/ECO FP24/835/HO/ECO FP24/841/HO/ECO FP39/830/HO/ECO FP39/835/HO/ECO FP39/841/HO/ECO FP80/830/HO/ECO FP80/835/HO/ECO FP80/841/HO/ECO
Pkg Qty 40 40 40 40 40 40 40 40 40 40 40 40 40 40
CCT (K) 3000 3500 4100 5000 6500 3000 3500 4100 3000 3500 4100 3000 3500 4100
CRI 85 85 85 85 85 85 85 85 85 85 85 85 85 85
Notes
, ,3,12, 13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
24
T5
24
22.2
Mini Bipin
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
39
T5
36
34
Mini Bipin
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
80
T5
60
57.6
Mini Bipin
13,14,17,24 , ,3,12,
13,14,17,24 , ,3,12,
13,14,17,24
Product Ordering Number Abbreviation 21042 21043 21044 FP54/835/C/HO/ECO FP54/841/C/HO/ECO FP54/850/C/HO/ECO
Pkg Qty 40 40 40
CRI 85 85 85
Notes
, ,3,12, 13,14,17,24,34 , ,3,12,
13,14,17,24,34 , ,3,12,
13,14,17,24,34
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
22
CIRCLINE 4-Pin T5
L I N E A R
Notes
,3,12, 13,14,17,24 ,3,12, 13,14,17,24 ,3,12 13,14,17,24 ,3,12, 13,14,17,24 ,3,12, 13,14,17,24 ,3,12, 13,14,17,24 ,3,12, 13,14,17,24 ,3,12, 13,14,17,24 ,3,12, 13,14,17,24
Nominal Wattage 22
Bulb T5
Base 2gX13
Ordering Abbreviation FPC22/830 FPC22/835 FPC22/841 FPC40/830 FPC40/835 FPC40/841 FPC55/830/HO FPC55/835/HO FPC55/841/HO
Pkg Qty 12 12 12 12 12 12 12 12 12
CCT (K) 3000 3500 4100 3000 3500 4100 3000 3500 4100
CRI 82 82 82 82 82 82 82 82 82
40
T5
F L U O R E S C E N T
55
T5
23
L I N E A R F L U O R E S C E N T
Base
Product Number 24538 24535 24544 24585 24540 24547 24542 24554 24588 24596 24599 24706
Pkg Qty 30 30 30 30 30 30 30 30 30 30 30 30
CCT (K) 3000 3000 3000 3500 3500 3500 4100 4100 4100 4200 6500 6500
CRI 52 70 80 70 70 80 70 80 87 60 88 80
Notes *, *, *, *, *, *, *, *,
, , , 3,8,12,13,17,36 , ,
F34/D30/SS/ECO
formerly F40/D30/SS/ECO
3,8,12,13,17,36 , ,
F34/D830/SS/ECO F34/D35/SS
3,8,12,13,17,36 , ,
3,8,12,13,17,36 , ,
F34/D35/SS/ECO
formerly F40/D35/SS/ECO
3,8,12,13,17,36 , ,
F34/D835/SS/ECO F34/D41/SS/ECO
3,8,12,13,17 , ,
3,8,12,13,17,36 , ,
F34/D841/SS/ECO F34CWX/SS
3,8,12,13,17,36 ,3,8,
12,13,17
F34CW/SS/ECO F34/DX/SS
*,
,
,3,8,
12,13,17 ,3,8,
12,13,17
F34/D865/SS
formerly F40/D865/SS
*,
,3,8,
12,13,17
*means this bulb meets Federal minimum efficiency standards For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
24
L I N E A R
Notes *, *, *, *,
, , , 3,12,13,17,23,36 , ,
Base
Product Number 24521 24543 24537 24546 24438 24441 24541 24553 24584 24683 24477 24570 24673
Ordering Abbreviation F40/D30/ECO F40/D830/ECO F40/D35/ECO F40/D835/ECO F40N F40CWX F40/D41/ECO F40/D841/ECO F40/D41 F40DSgN50 F40/DX F40/D865 F40/gO
Pkg Qty 30 30 30 30 30 30 30 30 30 30 30 30 10
CCT (K) 3000 3000 3500 3500 3600 4100 4100 4100 4100 5000 6500 6500
CRI 70 80 70 80 86 87 70 80 70 90 88 80
3,12,13,17,23,36 , ,
3,12,13,17,23,36 , ,
3,12,13,17,23,36 ,3,12,
F L U O R E S C E N T
13,17,23,36 , ,3,12,
13,17,23
*, *, *,
, ,
3,12,13,17,23,36 , ,
3,12,13,17,23 ,3,
12,13,17,23,36 ,3,12,
3,12,13,17,23 , ,3,12,
3,12,13,17,23
*,
,
,3,
3,12,13,17,23,36 ,
3,12,13,17,23
*means this bulb meets Federal minimum efficiency standards Specifications subject to change without notice. Symbols/Footnotes on pages 45-47
25
L I N E A R F L U O R E S C E N T
Base
Pkg Qty 30 30
CRI 52 60
Notes
,3,7, 12,13,17 ,3,7, 12,13,17
Base
Pkg Qty 30 30 30 30 30 30
Average Rated Life 3 Hours per start 18000 18000 18000 18000 18000 18000
CRI 52 80 70 80 60 76
Notes
,3, 12,13,17 ,3, 12,13,17 ,3, 12,13,17 ,3, 12,13,17 ,3, 12,13,17 ,3, 12,13,17
Base
Ordering Abbreviation
formerly FB40/WW/6/SS/ECO
Pkg Qty 12 12 12
CRI 52 70 60
Notes *,
, ,3, 8,12,13,17,36
FB34/WW/6/SS/ECO FB34/D35/6/SS
formerly FB40/D35/SS
*, *,
,
,3,
8,12,13,17,36 ,3,
FB34/CW/6/SS/ECO
formerly FB40/CW/6/SS/ECO
8,12,13,17,36
Base
Pkg Qty 12 12 12 12
Average Rated Life 3 Hours per start 18000 18000 18000 18000
CRI 70 80 70 70
Notes *, *, *, *,
,3, 12,13,17,36 ,3,
12,13,17,36 ,3,
12,13,17,36 ,3,
12,13,17,36
*means this bulb meets Federal minimum efficiency standards For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
26
Nominal Wattage 20
Bulb T9
Base 4-Pin
Ordering Abbreviation FC6T9/DCW/RS FC6T9/CW/RS FC8T9/WW/RS FC8T9/DCW/RS FC8T9/DSW/RP FC8T9/CW/RS FC8T9/D/RS FC9T9/DCW/RS FC9T9/DSW/RP/1/6 FC12T9/DCW/RS FC12T9/DSW/RP FC12T9/WW/RS FC12T9/CW/RS FC12T9/D/RS FC16T9/WW/RS FC16T9/DCW/RS FC16T9/CW/RS
Pkg Qty 6 12 12 6 6 12 12 6 6 6 6 12 12 12 12 6 12
Average Rated Life 3hrs/start 8000 8000 12000 12000 12000 12000 12000 10000 10000 15000 15000 15000 15000 15000 8000 8000 8000
CCT (K) 4100 4200 3000 4100 3000 4200 6500 4100 3000 4100 3000 3000 4200 6500 3000 4100 4200
CRI 80 60 52 80 70 60 76 82 82 80 70 52 60 76 80 80 60
Initial Lumens 25C/77F 750 750 1050 1050 1100 1050 900 2000 1900 1925 2100 1950 1925 1650 2500 2750 2500
L I N E A R
Notes
3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17 3,12,13,15,17
22
T9
8.00 - 8.50
4-Pin
F L U O R E S C E N T
30
T9
9.00 - 9.50
4-Pin
20114 20215
32
T9
11.5 - 12.0
4-Pin
40
T9
15.6 - 16.0
4-Pin
Base
Pkg Qty 15 15 15 15
CRI 52 48 60 60
Notes *, *, *, *,
,3,10, 12,13,17,36 ,3,
93.91 RecessedDC
10,12,13,17,36 ,3,10,
12,13,17,36 ,3,10,
12,13,17,36
High Output (800mA) Rapid Start Lamps for Cold Temperature Operation
Approx Lumens Initial (Mean) 25C/77F 8600 (6965) 8600 (6965) 7600 (6155)
Nominal Nominal Length MOL Wattage Bulb (in) (in) 110 T12 96
Base
Pkg Qty 15 15 15
CRI 60 60 76
Notes
, ,3,12, 13,17,25,36 ,3,12, 13,17,25 ,3,12, 13,17,25
93.91 RecessedDC
*means this bulb meets Federal minimum efficiency standards Specifications subject to change without notice. Symbols/Footnotes on pages 45-47
27
L I N E A R F L U O R E S C E N T
Base
Ordering Abbreviation F18T12/DSgN50/HO F24T12/CW/HO F24T12/D/HO F30T12/CW/HO F36T12/CW/HO F36T12/D/HO F42T12/CW/HO F42T12/D/HO F48T12/WW/HO F48T12/D35/HO F48T12/CW/HO F48T12/CW/HO/ECO F48T12/DSgN50/HO F48T12/D/HO F60T12/D35/HO F60T12/CW/HO F60T12/D/HO F64T12/CW/HO F64T12/D/HO
Pkg Qty 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30
Average Rated Life 3 Hours per start 9000 9000 9000 9000 9000 9000 9000 9000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000
CCT (K) 5000 4200 6500 4200 4200 6500 4200 6500 3000 3500 4200 4200 5000 6500 3500 4200 6500 4200 6500
CRI 90 60 76 60 60 76 60 76 52 70 60 60 90 76 70 60 76 60 76
Notes
,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17
35
T12
24
42
T12
30
45
T12
36
55
T12
42
39.91 RecessedDC
25342 25343
60
T12
48
46.00 RecessedDC
75
T12
60
57.91 RecessedDC
80
T12
64
61.91 RecessedDC
25352 25353
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
28
L I N E A R
Notes
,1,3, 12,13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,1,3,
Base
Product Number 25098 25177 27249 25281 25176 25171 25190 25189
Ordering Abbreviation F72T12/D830/HO F72T12/WW/HO F72T12/D35/HO F72T12/D835/HO F72T12/CW/HO F72T12/CW/HO/ECO F72T12/DSgN50/HO F72T12/D/HO F84T12/CW/HO F84T12/D/HO
Pkg Qty 15 15 15 15 15 15 15 15 15 15
Average Rated Life 3 Hours per start 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000
CCT (K) 3000 3000 3500 3500 4200 4200 5000 6500 4200 6500
CRI 80 52 70 80 60 60 90 76 60 76
69.91 RecessedDC
F L U O R E S C E N T
100
T12
84
81.91 RecessedDC
25384 25385
Nominal Nominal Length MOL Wattage Bulb (in) (in) 110 T12 96
Base
Product Number 25149 25152 25165 25166 25155 25184 25164 25185
Ordering Abbreviation F96T12/D30/HO F96T12/D830/HO F96T12/D35/HO F96T12/D835/HO F96T12/D841/HO F96T12/D41/HO F96T12/DSgN50/HO F96T12/D865/HO
Pkg Qty 15 15 15 15 15 15 15 15
Average Rated Life Hours per start 3hrs 12hrs 12000 12000 12000 12000 12000 12000 12000 12000 18800 18800 18800 18800 18800 18800 18800 18800
CCT (K) 3000 3000 3500 3500 4100 4100 5000 6500
CRI 70 80 70 80 80 70 90 80
Notes *, *, *, *, *, *,
,3, 12,13,17,36 ,3,
93.91 RecessedDC
12,13,17,36 ,3,
12,13,17,36 ,3,
12,13,17,36 ,3,
12,13,17,36 ,3,
*,
,3,
12,13,17,36
*means this bulb meets Federal minimum efficiency standards Specifications subject to change without notice. Symbols/Footnotes on pages 45-47
29
L I N E A R F L U O R E S C E N T
Nominal Nominal Length MOL Wattage Bulb (in) (in) 195 T12 96
Base
Pkg Qty 15
CRI 60
Notes
,3,11, 12,13,17
93.91 RecessedDC
Nominal Nominal Length MOL Wattage Bulb (in) (in) 115 T12 48
Base
Ordering Abbreviation F48T12/CW/VHO F48T12/D/VHO F60T12/CW/VHO F60T12/CW/VHO/LT F72T12/CW/VHO F72T12/CW/VHO/LT F72T12/D/VHO F96T12/CW/VHO F96T12/D/VHO
Pkg Qty 30 30 30 30 15 15 15 15 15
Average Rated Life 3 Hours per start 10000 10000 10000 10000 10000 10000 10000 10000 10000
CCT (K) 4200 6500 4200 4200 4200 4200 6500 4200 6500
CRI 60 76 60 60 60 60 76 60 76
Notes
,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17,22 ,3,12, 13,17 ,3,12, 13,17,22 ,3,12, 13,17 ,3,12, 13,17 ,3, 12,13,17
46.00 RecessedDC
135
T12
60
141
T12
60
160
T12
72
215
T12
96
93.91 RecessedDC
25209 25210
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
30
L I N E A R
Notes
,3,9, 12,13,17 ,3,9, 12,13,17 ,3,9, 12,13,17
Ordering Abbreviation F48T12/D35/SS F48T12/D41/SS F48T12/CW/SS F96T12/D41/SSP/ECO F96T12/DX/SS F96T12/DX/SS/ECO F96T12/CW/SS/ECO F96T12/WW/SS/ECO F96T12/D30/SS/ECO F96T12/D35/SS F96T12/D35/SS/ECO F96T12/D41/SS/ECO F96T12/CW/SS F96T12/CW/SS/ECO F96T12/D865/SS
Pkg Qty 30 30 30 15 15 15 15 15 15 15 15 15 15 15 15
CCT (K) 3500 4100 4200 4100 6500 6500 4200 3000 3000 3500 3500 4100 4200 4200 6500
CRI 70 70 60 82 88 88 60 52 70 70 70 70 60 60 80
57
T12
96
94
Single Pin
*,
F L U O R E S C E N T
3,9,12,13,17
60
T12
96
94
Single Pin
*, *, *,
3,9,12,13,17,36 , ,
3,9,12,13,17,36 , ,
3,9,12,13,17,36
*, *, *,
,
3,9,12,13,17,36 ,
3,9,12,13,17,36 , ,
3,9,12,13,17,36
*, *,
,
3,9,12,13,17,36 ,
3,9,12,13,17,36
*,
3,9,12,13,17,36
*means this bulb meets Federal minimum efficiency standards Specifications subject to change without notice. Symbols/Footnotes on pages 45-47
31
L I N E A R F L U O R E S C E N T
Ordering Abbreviation F24T12/CW F42T6/WW F42T6/D35 F42T6/CW F36T12/CW F64T6/WW F64T6/CW F72T8/WW F72T8/CW F72T8/D F48T12/D35 F48T12/CW/ECO F48T12/CW F48T12D/ECO F60T12/D35 F60T12/CW F60T12/D F96T8/CW F96T8/D F64T12/CW F64T12/D F72T12/D830 F72T12/D35
Pkg Qty 30 24 24 24 30 24 24 24 24 24 30 30 30 30 30 30 30 24 24 30 30 15 15
Average Rated Life 3 Hours per start 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 9000 9000 9000 9000 12000 12000 12000 7500 7500 12000 12000 12000 12000
CCT (K) 4200 3032 3500 4200 4200 3000 4200 3000 4200 6500 3500 4200 4200 6500 3500 4200 6500 4200 6500 4200 6500 3000 3500
CRI 60 52 70 60 60 52 60 52 60 76 70 60 60 76 70 60 76 60 76 60 76 80 70
Notes
,3,12, 13,17 ,3, 12,13,17 ,3, 12,13,17 ,3, 12,13,17 ,3,12, 13,17 ,3, 12,13,17 ,3, 12,13,17 ,3, 12,13,17 ,3, 12,13,17 ,3, 12,13,17 ,3, 12,13,17 , ,3,
25
T6
42
40
30
T12
36
34
38
T6
64
62
38
T8
72
70
Single Pin
39
T12
48
46
Single Pin
39
T12
48
46
12,13,17 ,3, 12,13,17 ,3,12, 13,17 ,3, 12,13,17 ,3, 12,13,17 ,3, 12,13,17 ,3,12, 13,17,36 ,3, 12,13,17,36 ,3, 12,13,17 ,3, 12,13,17
50
T12
60
58
51
T8
96
94
Single Pin
29666 29650
52
T12
64
62
Single Pin
26403 26404
55
T12
72
70
Single Pin
27255 27250
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
32
L I N E A R
Notes
,3,12, 13,17 ,3, 12,13,17 ,3,12, 13,17
Ordering Abbreviation F72T12/CW F72T12/D F84T12/CW F96T12/D30/ECO F96T12/D35 F96T12/D35/ECO F96T12/D835/ECO F96T12/CWX F96T12/D41/ECO F96T12/D841/ECO F96T12/DSgN50 F96T12/D865 F96T12/DX
Pkg Qty 15 15 15 15 15 15 15 15 15 15 15 15 15
CCT (K) 4200 6500 4200 3000 3500 3500 3500 4100 4100 4100 5000 6500 6500
CRI 60 76 60 70 70 70 80 87 70 80 90 80 88
70
T12
84
82
28417 29796 29685 29686 29838 29478 29798 29850 29833 29849 29500
75
T12
96
94
*,
3,12,13,17,36
F L U O R E S C E N T
*, *, *,
,
3,12,13,17,36 ,
3,12,13,17,36 , ,
*, *,
3,12,13,17,36 , ,
*,
,3,
3,12,13,17,36
12,13,17
*means this bulb meets Federal minimum efficiency standards Specifications subject to change without notice. Symbols/Footnotes on pages 45-47
33
L I N E A R F L U O R E S C E N T
PREHEAT LAMPS
Miniature T5 Preheat Lamps (Starter Required)
Avg Rated Life @3hrs/start 6000 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 7500 Approx Lumens Initial (Mean) @25C/77F 135 (115) 275 (240) 270 (235) 400 (350) 270 (235) 390 (340) 350 (305) 880 (765) 860 (750) 880 (765) 1325 (1150) 1325 (1150)
Ordering Abbreviation F4T5/CW F6T5/WW F6T5/CW F8T5/WW F8T5/CWX F8T5/CW F8T5/D F13T5/WW F13T5/CW F13T5/SW F18T5/CW/RS/SMBASE F18T5/WW/RS/SMBASE
Pkg Qty 24 24 24 24 24 24 24 24 24 24 24 24
CCT (K) 4200 3000 4200 3000 4100 4200 6500 3000 4200 3000 4200 3000
CRI 60 52 60 52 87 60 76 52 60 52 62 52
Notes
,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17
T5
8.91
T5
12
13
T5
21
18
T5
30
20909 20911
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
34
PREHEAT LAMPS
Standard T8 and T12 Preheat Lamps (Starter Required)
Avg Rated Life @3hrs/start 7500 7500 7500 9000 7500 7500 7500 7500 7500 9000 9000 9000 7500 7500 7500 7500 Approx Lumens Initial (Mean) @25C/77F 530 (460) 685 (645) 575 (560) 650 (565) 920 (845) 845 (735) 940 (845) 825 (720) 700 (655) 770 (670) 750 (655) 660 (575) 1190 (1035) 1280 (1080) 1360 (1130) 1400 (1200)
L I N E A R
Notes
,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17
Base
Ordering Abbreviation F13T8/CW F14T8/CW F14T8/D F14T12/CW F15T8/D830 F15T8/WW F15T8/D35 F15T8/CW F15T8/D F15T12/WW F15T12/CW F15T12/D F18T8CW/K24 F18T8CW/K26 F18T8CW/K28 F18T8CW/K30
Pkg Qty 24 24 24 30 24 24 24 24 24 30 30 30 24 24 24 24
CCT (K) 4200 4200 6500 4200 3000 3000 3500 4200 6500 3000 4200 6500 4200 4200 4200 4200
CRI 60 60 76 60 82 52 70 60 76 52 60 76 60 60 60 60
14
T8
15
14
T12
15
F L U O R E S C E N T
15
T8
18
15
T12
18
18
T8
24
23.78 Med Bipin 25.78 Med Bipin 27.78 Med Bipin 29.78 Med Bipin
26
28
30
35
L I N E A R F L U O R E S C E N T
PREHEAT LAMPS
Standard T8 and T12 Preheat Lamps (Starter Required)
Avg Rated Life @3hrs/start 9000 9000 9000 9000 9000 7500 7500 7500 7500 7500 7500 7500 Approx Lumens Initial (Mean) @25C/77F 1250 (1090) 1300 (1170) 1200 (1045) 880 (765) 1075 (935) 1670 (1455) 1750 (1525) 1730 (1505) 1850 (1610) 2150 (1870) 2180 (1895) 1850 (1655)
Base
Ordering Abbreviation F20T12/WW F20T12/D35 F20T12/CW F20T12/DSgN50 F20T12/D F25T12/CW/28 F25T12/WW/30 F25T12/CW/30 F25T12/CW/33 F30T8/WW F30T8/CW F30T8/D
Pkg Qty 30 30 30 30 30 30 30 30 30 24 24 24
CCT (K) 3000 3500 4200 5000 6500 4200 3000 4200 4200 3000 4200 6500
CRI 52 70 60 90 76 60 52 60 60 52 60 76
Notes
,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17 ,3,12, 13,17
25
T12
28
30
33
30
T8
36
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
36
L I N E A R
Notes
, ,3,12, 13,17,19,28,29 , ,3,12,
Base
Product Number 22271 22272 22374 22375 22376 21556 21557 21560
Ordering Abbreviation FO17/835/XP/ECO/SL FO17/841/XP/ECO/SL FO17/830/ECO/SL FO17/835/ECO/SL FO17/841/ECO/SL FO17/730/ECO/SL FO17/735/ECO/SL FO17/741/ECO/SL FO25/730/ECO/SL FO25/735/ECO/SL FO25/741/ECO/SL FO25/830/ECO/SL FO25/835/ECO/SL FO25/841/ECO/SL FO25/830/XP/ECO/SL FO25/835/XP/ECO/SL FO25/841/XP/ECO/SL FO28/830/XP/SS/ECO/SL FO28/835/XP/SS/ECO/SL FO28/841/XP/SS/ECO/SL FO28/850/XP/SS/ECO/SL FO32/730/ECO/SL FO32/735/ECO/SL FO32/741/ECO/SL
CCT (K) 3500 4100 3000 3500 4100 3000 3500 4100 3000 3500 4100 3000 3500 4100 3000 3500 4100 3000 3500 4100 5000 3000 3500 4100
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
F L U O R E S C E N T
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
25
T8
36
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
28
T8
48
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
32
T8
48
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29
37
L I N E A R F L U O R E S C E N T
Base
Product Number 22381 22382 22268 22383 22385 22386 22388 22276 22277 22278 22142 22390 22384 22298 22387 22389 22391 22392 22393
Ordering Abbreviation FO32/735/XP/ECO/SL FO32/741/XP/ECO/SL FO32750ECOSL FO32/830/ECO/SL FO32/835/ECO/SL FO32/841/ECO/SL FO32/850/ECO/SL FO32/830/XP/ECO/SL FO32/835/XP/ECO/SL FO32/841/XP/ECO/SL FO32/850/XP/ECO/SL FO32/865/XP/ECO/SL FO32/830/XPS/ECO/SL FO32/835/XPS/ECO/SL FO32/841/XPS/ECO/SL FO32/850/XPS/ECO/SL FO32/25W/835/XP/SS/ECO/SL FO32/25W/841/XP/SS/ECO/SL FO32/25W/850/XP/SS/ECO/SL FO40/735/ECO/SL FO40/741/ECO/SL FO40/830/XP/ECO/SL FO40/835/XP/ECO/SL
CCT (K) 3500 4100 5000 3000 3500 4100 5000 3000 3500 4100 5000 6500 3000 3500 4100 5000 3500 4100 5000 3500 4100 3000 3500
Notes
, ,3, 17,19,28,29 , ,3,
17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,6,12,
13,17,19,28,29 , ,3,6,12,
13,17,19,28,29 , ,3,6,12,
13,17,19,28,29 , ,3,12,
40
T8
60
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29 , ,3,12,
13,17,19,28,29
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
38
L I N E A R
Notes
, ,3,12, 13,17,28,29 , ,3,12,
Base
Pkg Qty 24 24 24 24 24 24
CRI 75 75 82 82 78 78
13,17,28,29 , ,3,12,
13,17,28,29 , ,3,12,
13,17,28,29 , ,3,12,
F L U O R E S C E N T
86
T8
96
21505 21507
13,17,28,29 , ,3,12,
13,17,28,29
Base
Pkg Qty 24 24 24 24 24 24
CRI 60 76 60 60 60 75
Notes
,3,12,13, 17,28,29 ,3,12,13, 17,28,29 ,3,12,13, 17,28,29 ,3,12,13, 17,28,29 ,3,12,13, 17,28,29 ,3,12,13, 17,28,29
18
T8
24
26
30
T8
36
Nominal Nominal Length MOL Wattage Bulb (in) (in) 165 T12 72
Base
Pkg Qty 8 8
CRI 60 60
Notes
,3,12,13, 17,22,32 ,3,12,13, 17,22,32
215
T12
96
39
L I N E A R F L U O R E S C E N T
Base
Ordering Abbreviation FP14/830/ECO/SL FP14/835/ECO/SL FP21/830/ECO/SL FP21/835/ECO/SL FP21/841/ECO/SL FP28/830/ECO/SL FP28/835/ECO/SL FP28/841/ECO/SL
Pkg Qty 40 40 40 40 40 40 40 40
CCT (K) 3000 3500 3000 3500 4100 3000 3500 4100 3000 3500 4100 5000 3500 4100 5000
CRI 85 85 85 85 85 85 85 85 85 85 85 85 85 85 85
Notes
,3,12,13, 14,17,24,28,29 , ,3,12,13,
14,17,24,28,29 , ,3,12,13,
21
T5
24
22
Mini Bipin
14,17,24,28,29 , ,3,12,13,
14,17,24,28,29 , ,3,12,13,
14,17,24,28,29 , ,3,12,13,
28
T5
48
46
Mini Bipin
14,17,24,28,29 , ,3,12,13,
14,17,24,28,29 , ,3,12,13,
14,17,24,28,29 , , ,3,12,
50
T5
48
13,14,17,24,28,29 , , ,3,12,
13,14,17,24,28,29 , , ,3,12,
13,14,17,24,28,29 , , ,3,12,
13,14,17,24,28,29 , ,3,12,13,
54
T5
48
14,17,24,28,29 , ,3,12,13,
14,17,24,28,29 , ,3,12,13,
14,17,24,28,29
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
40
L I N E A R
Notes
, ,3,8,12, 13,17,28,29 , ,3,12,13,
Base
Pkg Qty 30 30 30 30 30 15 30 15 15 15 15
CCT (K) 4200 3000 3500 4100 4200 4200 4200 4200 3500 4200 4200
CRI 60 80 80 80 60 60 60 60 80 60 60
40
T12
48
F40/D830/ECO/SL F40/D835/ECO/SL F40/D841/ECO/SL F48T12/CW/HO/SL F96T12/CW/SS/SL F60T12CWHOSL F72T12CWHOSL F72T12D835HOSL F72T12CWVHOLTSL F96T12CWVHOSL
17,23,28,29 , ,3,12,13,
17,23,28,29 , ,3,12,13,
17,23,28,29 ,3,12,13, 17,28,29 ,3,10,12, 13,17,28,29 ,3,12,13, 17,28,29 ,1,3,12,13, 17,28,29 ,1,3,12,13, 17,28,29 ,1,3,12, 13,17,28,29 ,3,12,13, 17,28,29
F L U O R E S C E N T
60
T12
48
96
75
T12
60
85
T12
72
70
85
T12
72
70
160 215
T12 T12
72 96
70 94
RDC RDC
41
L I N E A R F L U O R E S C E N T
Base
Pkg Qty 6 24 30 6 6 6 6
Life @ 3hrs/start Preheat 7500 30000 30000 9000 9000 20000 20000
CCT (K)
CRI 66
Notes
,3,12, 13,21 ,3,12, 13,17 ,3,12, 13,17
17
T8
24
32
T8
48
20
T12
24
3400
89
750 480
40
T12
48
24671 24660
3400
89
1700 1200
Miniature T2 Lamps
Life @ 3hrs/start PRS 10000 10000 10000 10000 10000 10000 10000 10000 10000 10000 Approx Lumens Initial (Mean) @25C/77F 330 (295) 330 (295) 540 (485) 540 (485) 750 (675) 750 (675) 750 (675) 930 (835) 930 (835) 930 (835)
Nominal Nominal Length MOL Wattage Bulb (in) (in) 6 T2 8.6 8.60
Base Axial
Ordering Abbreviation FM6/830 FM6/841 FM8/830 FM8/841 FM11/830 FM11/835 FM11/841 FM13/830 FM13/835 FM13/841
Pkg Qty 20 20 20 20 20 20 20 20 20 20
CCT (K) 3000 4100 3000 4100 3000 3000 4100 3000 3500 4100
CRI 80 80 80 80 80 80 80 80 80 80
Notes
2,3,12, 13,17,24,33 2,3,12, 13,17,24,33 2,3,12, 13,17,24,33 2,3,12, 13,17,24,33 2,3,12, 13,17,24,33 2,3,12, 13,17,24,33 2,3,12, 13,17,24,33 2,3,12, 13,17,24,33 2,3,12, 13,17,24,33 2,3,12, 13,17,24,33
T2
12.6
12.60 Axial
26237 26232
11
T2
16.6
16.60 Axial
13
T2
20.6
20.6
Axial
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
42
ICETRON
ICETRON
L I N E A R
Notes
,3,12,13, 14,18,30,31 ,3,12,13, 14,18,30,31 ,3,12,13, 14,18,30,31 ,3,12,13, 14,18,30,31 ,3,12,13, 14,18,30,31 ,3,12,13, 14,18,30,31 , ,3,4,12,
Nominal Wattage 40
Bulb T17
Product Number 26310 26311 26312 26313 26314 26315 26087 26088 26089
Ordering Abbreviation ICE40/835/RCT/2P ICE40/835/CIR/2P ICE40/841/RCT/2P ICE40/841/CIR/2P ICE40/850/RCT/2P ICE40/850/CIR/2P ICE70/835/2P/ECO ICE70/841/2P/ECO ICE70/850/2P/ECO ICE100/835/2P/ECO ICE100/841/2P/ECO ICE100/850/2P/ECO ICE150/835/2P/ECO ICE150/841/2P/ECO ICE150/850/2P/ECO ICE150/BL/2P
Pkg Qty 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Avg Rated Life @3hrs/start 100000 100000 100000 100000 100000 100000 100000 100000 100000 100000 100000 100000 100000 100000 100000 100000
CCT (K) 3500 3500 4100 4100 5000 5000 3500 4100 5000 3500 4100 5000 3500 4100 5000
CRI 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
T17
6.85
Mount Brkts
T17
7.54
Mount Brkts
T17
6.85
Mount Brkts
F L U O R E S C E N T
T17
7.54
Mount Brkts
T17
6.85
Mount Brkts
70
T17
12.32
Mount Brkts
13,14,18,30,31 , ,3,4,12,
13,14,18,30,31 , ,3,4,12,
13,14,18,30,31 , ,3,4,12,
100
T17
12.32
Mount Brkts
13,14,18,30,31 , ,3,4,12,
13,14,18,30,31 , ,3,4,12,
13,14,18,30,31 , ,3,4,12,
150
T17
16.28
Mount Brkts
13,14,18,30,31 , ,3,4,12,
13,14,18,30,31 , ,3,4,12,
13,14,18,30,31 , ,3,4,12,13,
14,18,26,30,31
43
ICETRON
L I N E A R F L U O R E S C E N T
Bulb T17
Pkg Qty 1
CRI 80
Notes
, ,3,4,12, 13,14,18,30,31
ICETRON Ballasts
Input Current (A) 0.36/0.16 0.66/0.29 0.66/0.29 0.88/0.37 0.88/0.37 1.28/0.54 1.28/0.54 1.34/0.58 1.34/0.58 Input Power (W) 43.75 79/77 79/77
Lamp Type ICE40 ICE70 ICE70 ICE100 ICE100 ICE100 ICE100 ICE150 ICE150
Rated Lumens 2800 6200 6200 8000 8000 8000 8000 12000 12000
Ballast Factor 1.00 1.05 1.05 1.00 1.00 1.38 1.38 1.00 1.00
System Lumens 2800 6500 6500 8000 8000 11000 11000 12000 12000
Notes
49753 QT 1x100 ICE/UNV-T 120-277 49756 QT 1x100 ICE/UNV-W 120-277 49753 QT 1x100 ICE/UNV-T 120-277 49756 QT 1x100 ICE/UNV-W 120-277 49772 QT 1x150 ICE/UNV-T 120-277 49773 QT 1x150 ICE/UNV-W 120-277 49772 QT 1x150 ICE/UNV-T 120-277 49773 QT 1x150 ICE/UNV-W 120-277
1.06/1.03 75/77 1.06/1.03 75/77 154/149 154/149 161/156 161/156 71/73 71/73 74/76 74/76
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
44
L I N E A R F L U O R E S C E N T
Footnote 1 2
Description May be operated at 100 watts (1000MA) same as F84T12/HO. Due to their small diameter, T2 miniature fluorescent lamps operate at higher surface temperatures than other fluorescent lamps. To avoid possible burns, do not touch the lamp during operation and allow sufficient cooling time before removing the lamp from the fixture. The typical bulb wall temperature during operation is 120C at the ends. The maximum allowable bulb wall temperature is 150C. To avoid electrical shock, turn electrical power off before removing or installing the lamp. Mean lumens are measured at 40% of average rated lamp life. The /2P version of the ICETRON lamp is supplied with a 24-inch lead wire terminated by a 2-Pin connector rather than the old 12-inch lead, 3-Pin connector design. The /2P versions are powered by QT1X100 ICE/UNV-T or QT1X150 ICE/UNV-T ballasts. Recommended to be used on any F96 T8 Instant Start circuit. It is not recommended to be used: (1) at lamp ambient temperatures below 60F or in drafty locations, (2) on low power factor ballast, or (3) inverter operated emergency lighting systems unless any of the above equipment is specifically listed for use with the OCTRON FO96 SUPERSAVER 55 watt T8 lamp. Any of the above situations could result in lamp starting and stabilization problems. SUPERSAVER lamps are recommended to be used on F32T8 ballasts with minimum open circuit voltage of 550V RMS at the lamp. Not recommended to be used: (1) in remotely ballasted fixtures with lamp open circuit voltages below 550V, (2) with Rapid Start ballasts unless the lamp open circuit voltage is greater than 570V, (3) in air handling fixtures, (4) on low power factor ballasts or (5) inverter operated emergency lighting systems unless the equipment is specifically listed for particular lamps. Any of the above situations could result in lamp starting and stabilization problems, or system compatibility issues. If an operating lamp is exposed to drafts or the ambient temperature falls below 60F (70F for 25W), striation (a rhythmic pulsing pattern of light running down the tube) and/or reduction in lamp brightness may occur. While visually disconcerting, neither behavior is damaging to the lamp and removing the cause (draft or temperature) will return the lamp to normal operation. Recommended only for use on 2-lamp, 30 watt rapid-start high power factor lead, indoor ballasts that meet ANSI standards. Not intended for use: (1) at lamp ambient temperatures below 60F or in drafty location, (2) on low power factor ballasts, (3) reduced current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above equipment is specifically listed for use with 25 watt lamps. Recommended for use on one or two lamp 40 watt rapid start, high power factor, lead, indoor ballasts that meet ANSI standards. Not intended for use: (1) at lamp ambient temperatures below 60F or in drafty locations, (2) on low power factor ballasts, (3) reduced current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above equipment is specifically listed for use with 34 watt lamps. Recommended for use on one or two lamp high power factor, lead, instant-start, indoor ballasts that meet ANSI standards. Not intended for use: (1) at lamp ambient temperatures below 60 degrees F or in drafty locations, (2) on low power factor ballasts, (3) reduced current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above equipment is specifically listed for use with 32 watt or 60 watt lamps. Recommended for use on one or two lamp high power factor, lead 8-foot lamp, high output, indoor ballasts that meet ANSI standards. Not intended for use: (1) at lamp ambient temperatures below 60F or in drafty locations, (2) on low powerfactor ballasts, (3) reduced current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless any of the above equipment is specifically listed for use with 95 watt lamps. Recommended for use on 2-lamp high power factor, lead, 8-foot lamp, very high output, indoor ballasts that meet ANSI standards. Not intended for use: (1) at lamp ambient temperatures below 60F or in drafty locations, (2) on low power factor ballasts, (3) reduced current/reduced light output ballasts, (4) dimming ballasts, or (5) on inverter operated emergency lighting systems unless equipment is specifically listed for use with 195 watt lamps. Approximate initial lumens after 100 hours operation. The life ratings of fluorescent lamps are based on 3 hour operating cycles under specified conditions and with ballast meeting ANSI specifications. If operating cycle is increased, there will be a corresponding increase in the average hours life.
3 4 5
10
11
12 13
45
L I N E A R F L U O R E S C E N T
20 21 22 23 24
25 26
27
28
29
30
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
46
Footnote 31
Description ICETRON Inductively Coupled Electrodeless Fluorescent lamp. Read these warnings and instructions before installing and using this lamp. Instructions for Installation and Use. (1) To avoid premature lamp or ballast failure and ensure proper lamp, ballast and system performance, make sure lamp, ballast and fixture are properly installed. Electrical interconnects, electrical grounds, thermal management and heatsinking specifications and requirements must be fully adhered to in all applications. (See OSRAM SYLVANIA ICETRON DESIGN GUIDE.) (2) Do not alter the electrical connector on lamp and/or ballast. To do so may adversely affect lamp operation, ballast life and/or emission of EMI (electromagnetic interference). (3) This product may cause interference with radios, cordless telephones and remote control devices. If interference occurs, relocate the radios, cordless telephones and/or remote control devices away from this product. A fluorescent jacketed lamp consists of a T12 (1-1/2 diameter) lamp enclosed inside a T14.5 (1-13/16 diameter) glass jacket. A jacketed fluorescent lamp operates efficiently over a wide range of climatic conditions, including extremes of cold and strong wind in which an unjacketed (bare) lamp would be inefficient or inoperable. The jacket size provides the clearance necessary to minimize damaging lamp-jacket contact; narrow bans of rubber placed between the lamp and the jacket further prevent contact. A weather-tight seal is formed by neoprene rubber end caps. Use only with electronic ballasts which have been specifically designed to operate T2 miniature fluorescent lamps and to reliably and safely control all lamp operating modes including end-of-lamp-life sensing circuitry. If a non-conforming ballast is used, very high temperatures (350C typical) may be generated at the ends of the lamp especially during end-of-lamp-life operation, causing the lamp to crack and resulting in potential fire, electrical shock or burn hazards. Amalgam T5 fluorescent lamps provide at least 90% light output from 10-70C (50-158F). Non-amalgam lamps provide 90% light output from 25-50C (77-122F). Lamps are OSRAM branded. Lamp will no longer be produced after July 14, 2012 due to 2009 DOE Rule Making for GSFL.
L I N E A R F L U O R E S C E N T
32
33
34 35 36
47
L I N E A R F L U O R E S C E N T
NOTES:
For the current listing of available products and more complete product information, please visit us at www.sylvania.com. Specifications subject to change without notice.
48
Compact Fluorescent
TABLE OF CONTENTS
Lamp Basics Competitive Cross Reference Guide Lamp and Base Diagrams Color Temperature and Rendering Guide DULUX S/E ECOLOGIC and DULUX S ECOLOGIC Lamps DULUX D/E ECOLOGIC and DULUX D ECOLOGIC Lamps DULUX T/E/IN ECOLOGIC and DULUX T ECOLOGIC Lamps DULUX L ECOLOGIC Lamps DULUX F Lamps Symbols and Footnotes 50 52 56 58 59 61 64 66 68 69
C O M P A C T F L U O R E S C E N T
The compact fluorescent lamp is an electric discharge device which utilizes a low pressure mercury vapor arc to generate ultra-violet (plus a little visible) energy. The ultra-violet energy is absorbed by a phosphor coat on the inside of the glass tube and converted by the phosphor to visible wavelengths; the wavelengths of the light generated are determined by the composition of the phosphor. In addition to the small amount of mercury vapor, the fluorescent tube contains an atmosphere of an inert gas, usually argon, krypton, neon, or a mixture of two or more of these gases. The pressure of the gases contained in the lamp is very low, usually from 2 to 3 torr. Atmospheric pressure is 760 torr.
BULB
A wide variety of compact fluorescent bulb shapes are available.
PHOSPHOR Coating inside the bulb transforms ultraviolet radiation into visible light. Color of light produced depends on composition of phosphor.
CATHODE Hot cathodes at each end of lamp are coated with emissive materials which emit electrons. Usually made of coiled-coil or single-coil tungsten wire.
EXHAUST TUBE Air is exhausted through this tube during manufacture and inert gas introduced into the bulb.
MERCURY A minute quantity of liquid mercury is placed in the bulb to furnish mercury vapor.
STEM PRESS The lead-in wires have an air tight seal here and are made of specific material to assure about the same coefficient of expansion as the glass.
LEAD-IN WIRES Connect to the base pins and carry the current to and from the cathodes and the mercury arc.
BASE Several different types used to connect the lamp to the electric circuit and to support the lamp in the lampholder.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
50
T(T4) 5.5 140 GX24Q-3 20885 L(T5) 22.6 573 2G11 20586
C O M P A C T F L U O R E S C E N T
Nominal Wattage Bulb Base MOL Symbols & Footnotes Ordering Abbreviation NEMA Generic Designation CCT CRI Initial & Mean Lumens
Design wattage on reference ballast. Actual wattage dependent on ballast. Describes the shape of the bulb. Base designations for compact fluorescent lamps are the NEMA designations. Please see page 57 for base illustrations. Maximum overall length. The actual length of the lamp measured from the bottom of the base to the top outside edge of the glass. In many cases, the bottom of the base is the bottom of the center post of the base of the lamp. Most symbols and footnotes that apply to a specific product will appear in this space. The explanations of the symbols and footnotes are at the end of the compact fluorescent section, please see page 69. A text description of the lamp. Please see below for several examples and explanations of some of the codes. Designation assigned by NEMA (National Electrical Manufacturers Association). Correlated Color Temperature. The degree of whiteness of the light. Expressed in Kelvins (K). Please see page 58 for more information. Color Rendering Index. A numbering system for rating the relative color rendering quality of a light source compared to a standard. Please see page 58 for more information. Initial lumens are measured when the lamp has been operating for 100 hours. Mean lumens are typically measured at 40% of the rated life of the lamp. Compact Fluorescent lamp lumens are measured at 25C (77F) and 35C (95F).
Symbols/Footnotes on page 69
51
C O M P A C T F L U O R E S C E N T
20325 20303 20327 20310 21274 20307 20329 20333 21134 20308 20331 20283 20335 20306 21135 20374 20397 20368 20375
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
52
C O M P A C T F L U O R E S C E N T
Symbols/Footnotes on page 69
53
C O M P A C T F L U O R E S C E N T
20875 20876 20877 20878 20879 20880 20881 20882 20883 20884 20885 20886 20887 20888 20871 20890 20895 20896 20897 20899 20794 20795 20796 20797
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
54
C O M P A C T F L U O R E S C E N T
Symbols/Footnotes on page 69
55
DULUX S
DULUX S/E
DULUX D
DULUX D/E
DULUX T
DULUX L
DULUX F
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
56
BASES
Pin-based compact fluorescent lamps have either 2 pins or 4 pins. Each 2-pin lamp has an internal starter and is designed for preheat, magnetic operation. The 4-pin lamps are designed for electronic ballast operation and are dimmable. These lamps have no internal starter; starting the lamps is a function of the ballast. Medium screw base, compact fluorescent lamps have integral ballasts.
C O M P A C T F L U O R E S C E N T
G 23
GX 23
G 23-2
GX 23-2
G 24 d2
G24 d3
G 24 q-1
G 24 q-2
G 24 q-3
2 G 11
2G7
2 GX 7
GX 24
GX 24 d-2
GX 24 d-3
GX 24 q-1
GX 24 q-2
GX 24 q-3
GX 24 q-4
GX 24 q-5
Symbols/Footnotes on page 69
57
For weight and measurement information, please visit www.sylvania.com LAMP DISPOSAL LABELING
C O M P A C T F L U O R E S C E N T
The following information appears on packages of fluorescent lamps. For more information on lamp disposal labeling, see the inside back cover of this catalog.
Hg
gE* BIAX Low wattage BIAX Double BIAX Triple BIAX High Lumen BIAX Ecolux (ECO)
* Trademarks or registered trademarks of General Electric Company ** Trademarks or registered trademarks of Philips
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
58
DULUX S/E
Base 2g7
Ordering Abbreviation CF5DS/E/827 CF5DS/E/841 CF7DS/E/827 CF7DS/E/841 CF9DS/E/827 CF9DS/E/841 CF13DS/E/827 CF13DS/E/830 CF13DS/E/841
Pkg Qty 50 50 50 50 50 50 50 50 50
CCT (K) 2700 4100 2700 4100 2700 4100 2700 3000 4100
CRI 82 82 82 82 82 82 82 82 82
Notes
,1,2, 4,5,9 ,1,2, 4,5,9 ,1,2, 4,5,9 ,1,2, 4,5,9 ,1,2, 4,5,9 ,1,2, 4,5,9 ,1,2, 4,5,9 ,1,2, 4,5,9 ,1,2, 4,5,9
C O M P A C T F L U O R E S C E N T
S (T4)
4.5
115
2g7
20312 20316
S (T4)
5.7
145
2g7
20313 20317
13
S (T4)
6.2
157
2gX7
Symbols/Footnotes on page 69
59
DULUX S
C O M P A C T F L U O R E S C E N T
Base g23
Ordering Abbreviation CF5DS/827/ECO CF5DS/841/ECO CF7DS/827/ECO CF7DS/835/ECO CF7DS/841/ECO CF7DS/850/ECO CF9DS/827/ECO CF9DS/835/ECO CF9DS/841/ECO CF9DS/850/ECO CF13DS/827/ECO CF13DS/830/ECO CF13DS/835/ECO CF13DS/841/ECO CF13DS/850/ECO
Pkg Qty 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
CCT (K) 2700 4100 2700 3500 4100 5000 2700 3500 4100 5000 2700 3000 3500 4100 5000
CRI 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82
Notes
,
, , , , , , , , , , , , , , ,
1,3,5,9,11 ,
1,3,5,9,11 ,
S (T4)
5.3
135
g23
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11 ,
S (T4)
6.5
165
g23
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11 ,
13
S (T4)
7.1
180
gX23
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
60
DULUX D/E
Base g24Q-2
Ordering Abbreviation
Pkg Qty 50 50 50 50 50 50
CRI 82 82 82 82 82 82
Notes
, , 1,2,4,5,9 , , 1,2,4,5,9 , , 1,2,4,5,9 , , 1,2,4,5,9 , , 1,2,4,5,9 , , 1,2,4,5,9 , , , , , ,
CF18DD/E/15W/SS/830/ECO CFQ18W/g24Q/830 CF18DD/E/15W/SS/835/ECO CFQ18W/g24Q/835 CF18DD/E/15W/SS/841/ECO CFQ18W/g24Q/841 CF26DD/E/21W/SS/830/ECO CFQ26W/g24Q/830 CF26DD/E/21W/SS/835/ECO CFQ26W/g24Q/835 CF26DD/E/21W/SS/841/ECO CFQ26W/g24Q/841
C O M P A C T F L U O R E S C E N T
21
D (T4)
6.5
166
g24Q-3
Base g24Q-1
Ordering Abbreviation CF13DD/E/827/ECO CF13DD/E/830/ECO CF13DD/E/835/ECO CF13DD/E/841/ECO CF18DD/E/827/ECO CF18DD/E/830/ECO CF18DD/E/835/ECO CF18DD/E/841/ECO CF26DD/E/827/ECO CF26DD/E/830/ECO CF26DD/E/835/ECO CF26DD/E/841/ECO
Pkg Qty 50 50 50 50 50 50 50 50 50 50 50 50
CCT (K) 2700 3000 3500 4100 2700 3000 3500 4100 2700 3000 3500 4100
CRI 82 82 82 82 82 82 82 82 82 82 82 82
Notes
, , 1,2,4,5,9 , ,
1,2,4,5,9 , ,
1,2,4,5,9 , ,
1,2,4,5,9 , ,
18
D (T4)
5.8
147
g24Q-2
1,2,4,5,9 , ,
1,2,4,5,9 , ,
1,2,4,5,9 , ,
1,2,4,5,9 , ,
26
D (T4)
6.5
166
g24Q-3
1,2,4,5,9 , ,
1,2,4,5,9 , ,
1,2,4,5,9 , ,
1,2,4,5,9
Symbols/Footnotes on page 69
61
DULUX D
C O M P A C T F L U O R E S C E N T
Base g24D-2
Ordering Abbreviation CF18DD/16W/SS/827/ECO CF18DD/16W/SS/830/ECO CF18DD/16W/SS/835/ECO CF18DD/16W/SS/841/ECO CF26DD/23W/SS/827/ECO CF26DD/23W/SS/830/ECO CF26DD/23W/SS/835/ECO CF26DD/23W/SS/841/ECO
Pkg Qty 50 50 50 50 50 50 50 50
CCT (K) 2700 3000 3500 4100 2700 3000 3500 4100
CRI 82 82 82 82 82 82 82 82
Notes
, , , 1,3,5,7,9,11 , , ,
1,3,5,7,9,11 , , ,
1,3,5,7,9,11 , , ,
1,3,5,7,9,11 , , ,
23
D (T4)
6.8
173
g24D-3
1,3,5,7,9,11 , , ,
1,3,5,7,9,11 , , ,
1,3,5,7,9,11 , , ,
1,3,5,7,9,11
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
62
DULUX D
Base g23-2
Ordering Abbreviation CF9DD/827/ECO CF9DD/830/ECO CF9DD/835/ECO CF13DD/827/ECO CF13DD/830/ECO CF13DD/835/ECO CF13DD/841/ECO CF18DD/827/ECO CF18DD/830/ECO CF18DD/835/ECO CF18DD/841/ECO CF26DD/827/ECO CF26DD/830/ECO CF26DD/835/ECO CF26DD/841/ECO
Pkg Qty 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50
CCT (K) 2700 3000 3500 2700 3000 3500 4100 2700 3000 3500 4100 2700 3000 3500 4100
CRI 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82
Notes
,
, , , , , , , , , , , , , , ,
1,3,5,9,11 ,
1,3,5,9,11 ,
C O M P A C T F L U O R E S C E N T
1,3,5,9,11 ,
13
D (T4)
4.6
118
gX23-2
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11 ,
18
D (T4)
6.0
153
g24D-2
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11 ,
26
D (T4)
6.8
173
g24D-3
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11 ,
1,3,5,9,11
Symbols/Footnotes on page 69
63
DULUX T/E/IN
C O M P A C T F L U O R E S C E N T
Base gX24Q-3
Product Ordering Number Abbreviation 21100 21101 21102 CF26DT/E/IN/21W/830/SS/ECO CF26DT/E/IN/21W/835/SS/ECO CF26DT/E/IN/21W/841/SS/ECO CF32DT/E/IN/28W/830/SS/ECO CF32DT/E/IN/28W/835/SS/ECO CF32DT/E/IN/28W/841/SS/ECO CF42DT/E/IN/38W/830/SS/ECO CF42DT/E/IN/38W/835/SS/ECO CF42DT/E/IN/38W/841/SS/ECO
Notes
, , , 1,2,4,5,9,10 , , ,
T (T4) 5.0
CFTR26W/gX24q/30 50 18000 3000 CFTR26W/gX24q/35 50 18000 3500 CFTR26W/gX24q/41 50 18000 4100 CFTR32W/gX24q/30 50 18000 3000 CFTR32W/gX24q/35 50 18000 3500 CFTR32W/gX24q/41 50 18000 4100 CFTR42W/gX24q/30 50 18000 3000 CFTR42W/gX24q/35 50 18000 3500 CFTR42W/gX24q/41 50 18000 4100
1,2,4,5,9,10 , , ,
1,2,4,5,9,10 , , ,
28
T (T4) 5.6
142
gX24Q-3
1,2,4,5,9,10 , , ,
1,2,4,5,9,10 , , ,
1,2,4,5,9,10 , , ,
38
T (T4) 6.5
163
gX24Q-4
1,2,4,5,9,10 , , ,
1,2,4,5,9,10 , , ,
1,2,4,5,9,10
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
64
DULUX T/E/IN
Base gX24Q-2
Product Ordering Number Abbreviation 20875 20876 20877 20878 CF18DT/E/IN/827/ECO CF18DT/E/IN/830/ECO CF18DT/E/IN/835/ECO CF18DT/E/IN/841/ECO CF26DT/E/IN/827/ECO CF26DT/E/IN/830/ECO CF26DT/E/IN/835/ECO CF26DT/E/IN/841/ECO CF32DT/E/IN/827/ECO CF32DT/E/IN/830/ECO CF32DT/E/IN/835/ECO CF32DT/E/IN/841/ECO CF42DT/E/IN/827/ECO CF42DT/E/IN/830/ECO CF42DT/E/IN/835/ECO CF42DT/E/IN/841/ECO CF57DT/E/IN/827/ECO CF57DT/E/IN/830/ECO CF57DT/E/IN/835/ECO CF57DT/E/IN/841/ECO
Notes
,
T (T4) 4.4
CFTR18W/gX24Q/827 50 12000 2700 CFTR18W/gX24Q/830 50 12000 3000 CFTR18W/gX24Q/835 50 12000 3500 CFTR18W/gX24Q/841 50 12000 4100 CFTR26W/gX24Q/827 50 16000 2700 CFTR26W/gX24Q/830 50 16000 3000 CFTR26W/gX24Q/835 50 16000 3500 CFTR26W/gX24Q/841 50 16000 4100 CFTR32W/gX24Q/827 50 16000 2700 CFTR32W/gX24Q/830 50 16000 3000 CFTR32W/gX24Q/835 50 16000 3500 CFTR32W/gX24Q/841 50 16000 4100 CFTR42W/gX24Q/827 50 12000 2700 CFTR42W/gX24Q/830 50 12000 3000 CFTR42W/gX24Q/835 50 12000 3500 CFTR42W/gX24Q/841 50 12000 4100 CFTR57W/gX24Q/827 50 12000 2700 CFTR57W/gX24Q/830 50 12000 3000 CFTR57W/gX24Q/835 50 12000 3500 CFTR57W/gX24Q/841 50 12000 4100
, , , , , , , , , , , , , , , , , , , ,
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
C O M P A C T F L U O R E S C E N T
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
26
T (T4) 5.0
126
gX24Q-3
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
32
T (T4) 5.6
142
gX24Q-3
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
42
T (T4) 6.5
163
gX24Q-4
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
57
gX24Q-5
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
1,2,4,5,9,10 ,
1,2,4,5,9,10
Symbols/Footnotes on page 69
65
DULUX L
C O M P A C T F L U O R E S C E N T
Base
Ordering Abbreviation CF13DT/E/827/ECO CF13DT/E/830/ECO CF13DT/E/835/ECO CF13DT/E/841/ECO CF18DT/E/827/ECO CF18DT/E/841 CF26DT/E/827/ECO CF32DT/E/827/ECO
Pkg Qty 50 50 50 50 50 50 50 50
CCT (K) 2700 3000 3500 4100 2700 4100 2700 2700
CRI 82 82 82 82 82 82 82 82
Notes
,
106 gX24Q-1
, , , , , , , ,
1,2,4,5,9 ,
1,2,4,5,9 ,
1,2,4,5,9 ,
1,2,4,5,9 ,
18
T (T4)
4.6
116 gX24Q-2
20760 20739
1,2,4,5,9 ,
1,2,4,5,9 ,
26
T (T4)
5.2
124 gX24Q-3
20767 20768
1,2,4,5,9 ,
32
T (T4)
5.8
147 gX24Q-3
1,2,4,5,9
Base
Pkg Qty 50 50
CRI 82 82
Notes
,
123 gX24D-2
, ,
1,3,5,9,11 ,
26
T (T4)
5.4
138 gX24D-3
1,3,5,9,11
Base 2g11
Pkg Qty 10 10 10 10 10 10
CRI 82 82 82 82 82 82
Notes
,
, , ,
,
1,2,4,5,9,12 ,
1,2,4,5,9,12 ,
1,2,4,5,9,12 , ,
25
L (T5)
22.4
570
2g11
1,2,4,5,9,12 , , ,
1,2,4,5,9,12 , , ,
1,2,4,5,9,12
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
66
DULUX L
Base 2g11
Ordering Abbreviation FT18DL/830/ECO FT18DL/835/ECO FT18DL/841/ECO FT18DL/830/RS/ECO FT18DL/835/RS/ECO FT18DL/841/RS/ECO FT24DL/830/ECO FT24DL/835/ECO FT24DL/841/ECO FT36DL/830/ECO FT36DL/835/ECO FT36DL/841/ECO FT40DL/830/RS/ECO FT40DL/835/RS/ECO FT40DL/841/RS/ECO FT40DL/850/RS/ECO FT50DL/830/RS/ECO FT50DL/835/RS/ECO FT50DL/841/RS/ECO FT55DL/830/ECO FT55DL/930/ECO FT55DL/835/ECO FT55DL/841/ECO FT55DL/954/ECO
Pkg Qty 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10
CCT (K) 3000 3500 4100 3000 3500 4100 3000 3500 4100 3000 3500 4100 3000 3500 4100 5000 3000 3500 4100 3000 3000 3500 4100 5400
CRI 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 90 82 82 90
Notes
,
, , , , , , , , , , , , , , , , , , , , , , , ,
1,2,4,5,9 ,
1,2,4,5,9 ,
C O M P A C T F L U O R E S C E N T
1,2,4,5,9 ,
L (T5)
10.5
267
2g11
1,2,4,5,9 ,
1,2,4,5,9 ,
1,2,4,5,9 ,
24
L (T5)
12.9
326
2g11
1,2,4,5,6,9 ,
1,2,4,5,6,9 ,
1,2,4,5,6,9 ,
36
L (T5)
16.6
422
2g11
1,2,4,5,6,9 ,
1,2,4,5,6,9 ,
1,2,4,5,6,9 ,
40
L (T5)
22.6
573
2g11
1,2,4,5,9,12 ,
1,2,4,5,9,12 ,
1,2,4,5,9,12 ,
1,2,4,5,9,12 ,
50
L (T5)
22.6
573
2g11
1,2,4,5,9,12 ,
1,2,4,5,9,12 ,
1,2,4,5,9,12 ,
55
L (T5)
21.1
535
2g11
1,2,4,5,9 ,
1,2,4,5,9 ,
1,2,4,5,9 ,
1,2,4,5,9 ,
1,2,4,5,9
Symbols/Footnotes on page 69
67
DULUX F
C O M P A C T F L U O R E S C E N T
Base 2g10
Pkg Qty 10 10 10 10
CRI 82 82 82 82
Notes
,1,2, 4,5,8,9 ,1,2, 4,5,8,9 ,1,2, 4,5,8,9 ,1,2, 4,5,8,9
24
F (T5)
6.7
171
2g10
36
F (T5)
8.5
217
2g10
20559
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
68
C O M P A C T F L U O R E S C E N T
5 6 7 8 9 10
11 12
69
NOTES:
C O M P A C T F L U O R E S C E N T
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
70
TABLE OF CONTENTS
Lamp Basics Lamp, Base and Operating Position Diagrams Product Family Guide 72 75 76
METALARC POWERBALL EL ECOLOGIC Lamps 78 METALARC POWERBALL Ceramic PAR Lamps METALARC POWERBALL Ceramic T Lamps METALARC POWERBALL Ceramic E17 & ET23.5 Lamps METALARC POWERBALL Cermaic PRO-TECH E17 & High Wattage Lamps METALARC Pulse Start Lamps METALARC SUPER Lamps METALARC Lamps LUMALUX and LUMALUX PLUS Lamps
79 80 81 82 83 87 88 90 91 94 94 95 95 96 102
Mercury Vapor Lamps Low Pressure Sodium Lamps Competitive Cross Reference Guide Lamp Warnings
Color coding system: Premium products Other Standard products Enhanced red (R9) color rendering products High Pressure Sodium lamps 71
Products to be discontinued
OSRAM SYLVANIA: THE LEADER IN ENERGY-SAVING HID LAMPS UNDERSTANDING HIGH INTENSITY DISCHARGE LIGHTING
A brief description of the catalog format and related terminology will assist the reader in understanding the information presented in this section. All product families are listed in ascending wattage, followed by alphabetical bulb designation to simplify lamp identification. Performance ratings are based on tests conducted under controlled conditions on AC circuits with auxiliary equipment meeting current published ANSI specifications. Lamp performance under typical service conditions may vary from rated values. Ratings and specifications are subject to change without notice. ANSI CODE This is a unique code that describes the class and the electrical characteristics of the lamp and ballast as well as the fixture requirements. The code is developed and assigned by the American National Standards Institute (ANSI). It is intended to aid in matching the lamp to both the correct ballast and to a luminaire with the required features. The ANSI CODE consists of type of lamp (S = HPS, H = Mercury, M = Metal Halide, L = LPS, C = Ceramic Metal Halide), followed by the ballast number, and for metal halide and Ceramic metal halide lamps followed by the fixture requirement (O, E, S, F). The emergence of electronic ballasts to operate metal halide lamps has produced additional need to separate the lamp designation of quartz and ceramic metal halide lamps, as there can be some important differences in system performance. Therefore the C lamp designation from NEMA has been introduced going forward for future differentiation of ceramic metal halide lamps and they will begin to be labeled accordingly. ARC LENGTH Arc length is the dimension of the arc discharge measured from one electrode tip to the other. This is useful for optical design of reflectors and affects fixture efficiency. AVERAGE LIFE (HOURS) The average life of a lamp is based on vertical operation (unless otherwise noted) of representative lamps operated under controlled conditions of at least 10 hours per start (except for M1500 and BRITELINE lamps, which are based on 5 hours per start). Average life is defined as the total operation hours at which 50% (Median) of any group of lamps is still operating (except for most High Pressure Sodium and Mercury lamps, for which 65% of the lamps are operating at the end of life denoted by a + next to the life rating). Variations in operating conditions such as bulb and base temperatures and line voltage can also affect lamp life. Regular operation of lamps with off times less than the hot restrike time will shorten lamp life. For hot restrike values of specific lamp types, please refer to the SYLVANIA Metal Halide Lamp Specification Guide. Operating cycles shorter than 10 hours per start will reduce lamp life as follows: 5 hours / start Approximately 75% of rating 2.5 hours / start Approximately 55% of rating 1.25 hours / start Approximately 40% of rating BASE Most SYLVANIA HID lamp bases for general lighting are made of corrosionresistant brass with special lubricant to provide easy removal at end of lamp life. See page 75 for all base illustrations. GU6.5 Bipin bases are used on the smallest HID lamps and conveniently twist&lock feature provides secure installation. G8.5 Durable bipin bases have special center presses that secure lamps in the socket. G12 Ceramic bipin bases are used on T6, T7.5 single ended lamps. E26 Medium Medium (MED) bases are used on lamps in E17 bulbs and are limited to 175W maximum. E26 Medium Skirted Medium skirted (Med Skt) bases consist of a medium brass base with a skirt, which is mechanically connected to a PAR38 bulb. E39 Mogul All (MOG) bases are embossed with letters and numbers representing months and years. The date of installation can be recorded by marking the letter of the current month and the number that coincides with the last digit of the current year. EX39 Exclusionary Mogul Base Exclusionary Mogul bases (EXCL MOG) are bases used on metal halide lamps having shrouded arc tubes, permitting them to be used in open fixture applications. These bases are compatible with exclusionary or standard mogul sockets. E39 POM Position Oriented Mogul (POM) bases are used on lamps designed to operate only in the horizontal position and require a special POM socket. A pin located on the base engages in a slot within the POM socket ensuring proper operating position of the lamp within the fixture. Rx7s / R7s Recessed Single Contact SYLVANIA double-ended HID lamps with recessed single contact (RSC) bases have silver plated contacts to provide maximum electrical contact. BULB Each bulb description consists of a letter to indicate bulb shape, followed by numbers that indicate maximum bulb diameter in 1/8 inch increments. For example, a BT37 bulb is a blown shape with a tubular top, 3-7/8 of an inch or 4-5/8 inches in diameter. Illustrations of bulb shapes are shown on page 75. Although SYLVANIA HID bulbs are made of glass designed to resist thermal shock in normal applications, they must be shielded from direct contact with liquids, such as rain, during operation to avoid bulb breakage. COLOR RENDERING INDEX (CRI) Color Rendering Index (CRI) is an international scale (numbering system) up to 100 indicating the relative color rendering quality of a light source when compared to a standard reference light source of the same chromaticity (color temperature). The CRI expresses the degree to which colors will appear familiar or natural under the light source selected. In general, the higher the CRI number, the better the color rendering properties of the light source being measured. The color rendering index of any two like sources should only be compared if those sources have the same correlated color temperature (CCT). CORRELATED COLOR TEMPERATURE (CCT) The correlated color temperature of a light source, expressed in Kelvin (K), is a means of describing the appearance or chromaticity of the source. The correlated color temperature of the light source contributes to the visual appearance of the lighted space. Warm light sources have a low color temperature (2000-3000K) and feature more light in the red/orange/yellow range. Light with a higher color temperature (>4000K) features more blue and is referred to as cool. With new installations, or group relamps, all color performance evaluations should be made after at least 100 hours of operation (at recommended operating cycles) to allow the lamps to stabilize. Additional changes in chemistry within the arc tube over the life of the lamp may also cause the color temperature to shift as the lamp gets closer to the end of its rated life. To minimize color variation within an installation, it is recommended that HID lamps be group relamped and run on equal operating cycles. DIMMING HID Most SYLVANIA HID products can be dimmed on stepped, bi-level dimming systems provided specific guidelines are followed. Generally, most Metalarc metal halide lamps can be dimmed down to 50% of rated wattage depending on the lamp type and operating position. LUMALUX high pressure sodium lamps can also be dimmed down to 50% of rated wattage. In addition to lower light output, HID lamps may shift in overall color and exhibit a lower color rendering index (CRI) when operated in a dimmed mode. Some restrictions apply to both the operation of the ballast and lamp. For more information on dimming, please reference NEMA guidelines or contact a SYLVANIA representative. FIXTURE REQUIREMENT Developed by the American National Standard Institute (ANSI), the fixture requirement code describes the type of fixture required for each lamp type. See lamp warnings for additional information and proper operating instructions. Operating cycles shorter than 10 hours per start will reduce lamp life as follows: E = Lamps classified as E-type are to be used only in suitably rated enclosed luminaires. O = Lamps classified as O-type, comply with ANSI Standard C78.389 for containment testing and may be used in open luminaires. S = When operated within 15 degrees of vertical, this lamp may be operated in an open luminaire provided the installation is not near people or flammable or combustible material, otherwise it must be operated in a suitably enclosed luminaire. F = F-rated lamps require an enclosed fixture with a UV filter and lens interlock. The 2005 NEC requires that luminaires which use a metal halide lamp shall be provided with either a containment barrier that encloses the lamp (historically referred to as an enclosed luminaire) or shall be provided with a means, typically a special lampholder, that will only accept an ANSI Type-O metal halide lamp. (Exception: This requirement will not apply to open luminaires with thick-glass parabolic reflector PAR lamps.)
H I D
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
72
H I D
36,000 27,000
20,000V 36,000V 23,500V 65 15,000H 30,000H 19,000H 15,000V 110,000V 96,000V 65 9000H 107,800H 86,300H
1000 BT37
Please refer to the Understanding High Intensity Discharge section on this and previous pages for definitions and explanations of the category headers.
73
H I D
PHYSICAL DIMENSIONS
BRITELINE Bulb T7 T8 T9 HQI Bulb R30 MERCURY VAPOR Bulb E17 ET23.5 ED28 ED37 BT56 PAR38 LCL 3.75 5 5 7 9.5 PHYSICAL SIZE LCL 127 127 127 PHYSICAL SIZE LCL (dimensions in mm) MOL 256 254 254 (dimensions in inches) MOL 3.5 (dimensions in inches) MOL 5.44 7.5 8.31 11.5 15.38 5.44 METALARC METAL HALIDE Physical size of all Metalarc lamps Bulb T4/TF T4.5/TC T6 T6 (DE) T7.5 PAR20 PAR30LN PAR38 E17/ED17 ET18 (250W) ET18 (400W) ET23.5 BT28/ED28 BT37 BT56 LCL 1.18 2 2.2 2.25 2.2 3.4 5.75 6.14 4.49 5 7 9.5 (dimensions in inches) MOL 2.24 3.19 3.94 4.5 4.13 3.65 4.76 5.32 5.44 9.75 9.75 6.97 8.31 11.5 15.38
LUMALUX HIgH PRESSURE SODIUM Physical size of all LUMALUX lamps Bulb T7 T14.5 E17 ET18 ET23.5 E25 BT28 BT37 LCL 5 6.89 3.43 5.75 5 8.75 5 7 (dimensions in inches) MOL 10.06 11.22 5.43 9.75 7.75 15.08 8.98 11.5
T4.5 Lamps
LCL
MOL LCL
MOL
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
74
BULBS
A bulb designation consists of a letter(s) to indicate the shape and a number(s) to indicate the approximate maximum diameter in eighths of an inch. Thus, an E17 lamp is an Ellipsoidal shape and 1-7/8 of an inch or 2-1/8 inches in diameter. Other letter designations include: BT = Bulbous Tubular; E or ED = Ellipsoidal; ET = Ellipsoidal Tubular; PAR = Parabolic; R = Reflector; T = Tubular.
EL PAR30LN EL PAR38
E17
ET18
ET23.5
E25
ED37
BT28
BT37
BT56
PAR20
PAR30 LN
PAR38
R30
T7.5 HQI
T4
T6, T7.5
T4.5
T17, T21
BASES
Lamps with screw bases have one lead-in wire soldered or welded to the center contact and the other soldered or welded to the upper rim of the base shell. Bases with ceramic bodies have internal leads welded to either silver-plated contacts or external lead wires.
H I D
GU6.5
G8.5
G12
E39 POM
E39
EX39
E26 Skt
E26
BY22d
RSC
OPERATING POSITIONS
A designated operating position assures maximum lamp performance. Where it is not specified, the lamp is suitable for operation in any position.
Vertical BU-HOR
Vertical BD-ONLY
Vertical BU-ONLY
UNIVERSAL U
Horizontal HOR
Double-Ended HOR
75
LOWER SUPPORT
H I D
STEM BASE
METALARC PRO-TECH (MP) These are specially designed lamps that incorporate a protective shroud to contain a non-passive arc tube failure. Metalarc Pro-Tech lamps can be used in open or enclosed fixtures. Dedicated bases are standard on both low and high wattage lamp types. METALARC POWERBALL CERAMIC (MC or MCP) POWERBALL lamps use a patented round ceramic arc tube, which allows for a more uniform arc tube temperature, higher color rendering (>85) and improved color consistency. These lamps are ideal for applications that demand the best in color performance. METALARC POWERBALL EL (MCP) The self-ballasted POWERBALL EL lamps offer energy saving solutions for applications desired superior light quality and are ideal replacements for halogen or incandescent lamps. METALARC PULSE START (M/PS) METALARC Pulse Start lamps utilize metal halide performance with proven ignitor technology for longer life, improved lumen maintenance and reduced color shift over lamp life compared to standard metal halide products. Lamp configurations include low and high wattage types, both clear and coated. METALARC PRO-TECH designs are also available for open fixture applications. All METALARC products lower than 175W and all METALARC POWERBALL products utilize Pulse Start technology exclusively. METALARC SUPERSAVER (M/SS) Constructed with an enhanced arc tube for peak performance, METALARC SUPERSAVER lamps are designed as energysaving, replacement metal halide lamps. The 360W SUPERSAVER lamp is a direct retrofit for existing 400W products, the 950W SUPERSAVER replaces 1000W lamps and the 150W SUPERSAVER replaces 175W lamps no ballast change is required. METALARC BRITELINE (M) These double-ended lamps are designed for compact fixtures, which provide excellent optical control and high efficiency. These higher wattage lamps are particularly well suited for sports lighting and outdoor floodlighting applications.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
76
LUMALUX PLUS / ECO AND LUMALUX PLUS These environmentally friendlier lamps contain significantly less Mercury than standard high pressure sodium lamps. They will not cycle at the end of life and are rated for 40,000 hours life. All lamps operate on existing high pressure sodium ballasts. LUMALUX Plus / ECO lamps are designed with lead-free bases and they pass the existing Federal TCLP limits.* LUMALUX AND LUMALUX / ECO Available in a broad range of wattages, in both clear and coated configurations, LUMALUX and LUMALUX / ECO lamps are ideal for a variety of applications. LUMALUX medium based lamps are available in wattages ranging from 35-150 watts while mogul based lamps are offered in 50-1000 watts. The mogul based LUMALUX / ECO lamps operate on standard high pressure sodium ballasts and pass the Federal TCLP text. * LUMALUX STANDBY These lamps are designed with two arc tubes to provide instant restrike capability in the event of a momentary power interruption. With almost twice the life of standard high pressure sodium lamps, LUMALUX Standby lamps are a great way to reduce maintenance costs. SOX These energy efficient low pressure sodium lamps emit a characteristic yellow light that is ideal for certain exterior street and area lighting. *based on NEMA LL Series Standards
STEEL FRAME
VACUUM
H I D
STANDARD MERCURY Available in a wide range of lamp types from 75-1000 watts, in both clear and coated configurations, Mercury vapor lamps are ideal for a variety of lighting applications. PAR lamps offer floodlighting and ultra-violet spectra for special lighting applications.
STEM BASE
77
EL PAR30LN
PAR38
Watts 24
Bulb PAR30LN
Base E26Med
Universal 12000 21500 Universal 12000 Universal 12000 Universal 12000 5000 3700 2500
PAR38
E26Med
64305 64237
Universal 12000 26000 Universal 12000 12600 Universal 12000 Universal 12000 5600 2100
H I D
64306 64783
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
78
PAR30LN
PAR20
PAR38
Watts 20
Bulb PAR20
Base E26Med
10 Universal 12000 10500 30 Universal 12000 2650 10 Universal 12000 21000 30 Universal 12000 4000 10 Universal 12000 16000 30 Universal 12000 4000 10 Universal 12000 20000 30 Universal 12000 5000 10 Universal 12000 36000 30 Universal 12000 7500 10 Universal 12000 39600 30 Universal 12000 8000 46 Universal 12000 3500 9 Universal 12000 70000
PAR30LN
E26Med
64879 64878
MCP20PAR30LN/U/830/SP/ECOPB C156/O 6 MCP20PAR30LN/U/830/FL/ECOPB MCP39PAR20/U/940/SP MCP39PAR20/U/940/FL MCP39PAR20/U/830/SPPB MCP39PAR20/U/830/FLPB MCP39PAR30LN/U/940/SP/ECO MCP39PAR30LN/U/940/FL/ECO C156/O 6 C130/O 12 C130/O 12 C130/O 12 C130/O 12 C130/O 6 C130/O 6
39
PAR20
E26Med
H I D
PAR30LN
E26Med
70
PAR30LN
E26Med
27 Universal 12000 13000 12 Universal 12000 42000 30 Universal 12000 12000 46 Universal 12000 5000 15 Universal 15000 40000 25 Universal 15000 16000 65 Universal 15000 3500 15 Universal 15000 58000 25 Universal 15000 25000 60 Universal 15000 6000 15 Universal 15000 50000 25 Universal 15000 28000 65 Universal 15000 6500
MCP70PAR30LN/U/930/VWFL/ECO PB C139/O 6 MCP70PAR38/U/830/SP/ECOPB MCP70PAR38/U/830/FL/ECOPB MCP70PAR38/U/VWFL/830/ECOPB MCP100PAR38/U/830/SP/ECOPB MCP100PAR38/U/830/FL/ECOPB C98/O C98/O C98/O C90/O C90/O 6 6 6 6 6 6
100
150
C102/O 6 C102/O 6
MCP150/PAR38/U/830/VWFL/ECOPB C102/O 6
The first letter of the ANSI code represents the lamp type; C for ceramic metal halide and M for quartz metal halide. The numbers following the lamp type refer to the electrical characteristics required by the ballast to start and operate the lamp reliably. Ceramic, C, or quartz, M lamps with the same electrical characteristic number will operate on the same ballast (per ANSI C78.380-2007). For example, a 150W ceramic lamp with a C102 designation will operate on a 150W metal halide ballast with an M102 designation and vice versa. 2 Lamps with a E26 medium skirt base are not compatible with exclusionary medium sockets.
1
79
T4
T4.5
T6, T7.5
METALARC POWERBALL Ceramic TUBULAR SINGLE ENDED AND DOUBLE ENDED Lamps
HIGH CRI, PULSE START, UV STOP METAL HALIDE LAMPS FOR ENCLOSED FIXTURES ONLY
See product information bulletin (HID054) for product details ANSI Code1/ Fixture Req. C186/E C156/E C130/E Avg Rated Life (hrs) 15000 15000 15000 Approx Lumens Initial (Mean) 1200 (9002) 1700 (1275) 3400 (25502) 1700 (1275) 3400 (2720) 6300 (5040) 2800 (22402) 3400 (2720) 3300 (2640) 6700 (5360) 6400 (5120) 7000 (5600) 9500 (76002) 14500 (11600) 15500 (12400) 6900 (5520) 14800 (11840) Lamp Efficacy (LPW) 80 85 87
Watts
Bulb
Base
Pkg Qty 12 12 12
CRI 82 85 90
TF
15 T4 gU6.5
20
T4
gU6.5
39
T4
gU6.5
TC
H I D
20
T4.5
g8.5
12 12 12
83 82 95
85 87 90
39
T4.5
g8.5
70
T4.5
g8.5
T6 and T7.5
39 T6 g12
MC39T6/U/g12/930 MC39T6/U/g12/830PB MC39T6/U/g12/940PB MC70T6/U/g12/940PB MC70T6/U/g12/930PB MC70T6/U/g12/830PB MC100T6/U/g12/830 MC150T7.5/U/g12/940PB MC150T7.5/U/g12/830 MC70T6/DE/830PB MC150T7.5/DE/830PB
C130/E C130/E C130/E C139/E C139/E C139/E C191/E C142/E C142/E C139/E C142/E
12 12 12 12 12 12 12 12 12 12 12
Clear Clear Clear Clear Clear Clear Clear Clear Clear Clear Clear
Universal Universal Universal Universal Universal Universal Universal Universal Universal HOR 45 HOR 45
15000 15000 15000 15000 15000 15000 15000 15000 15000 12000 12000
93 82 90 93 95 87 85 95 89 88 91
3000 3000 4200 4200 3000 3000 3000 4200 3000 3000 3000
72 87 85 96 91 100 95 97 103 99 99
70
T6
g12
100
T6
g12
150
T7.5
g12
70
T6
RX7s
64793 64794
150
1
T7.5
RX7s
The first letter of the ANSI code represents the lamp type; C for ceramic metal halide and M for quartz metal halide. The numbers following the lamp type refer to the electrical characteristics required by the ballast to start and operate the lamp reliably. Ceramic, C, or quartz, M lamps with the same electrical characteristic number will operate on the same ballast (per ANSI C78.380-2007). For example, a 150W ceramic lamp with a C102 designation will operate on a 150W metal halide ballast with an M102 designation and vice versa. 2 Preliminary data, visit www.sylvania.com for updates.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
80
E17
ET23.5
Watts
Bulb
Base
Ordering Abbreviation MC70/U/MED/940 MC70/C/U/MED/940 MC70/U/MED/830 MC70/C/U/MED/830 MC100/U/MED/940 MC100/C/U/MED/940 MC100/U/MED/830 MC100/C/U/MED/830 MC150/U/MED/940 MC150/C/U/MED/940 MC150/U/MED/830 MC150/C/U/MED/830
Pkg Qty 12 12 12 12 12 12 12 12 12 12 12 12
Lamp Finish Clear Coated Clear Coated Clear Coated Clear Coated Clear Coated Clear Coated
Operating Position Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal
CRI 90 90 88 88 90 90 88 88 90 90 85 85
CCT (K) 4000 3800 3000 3000 4000 3800 3000 3000 4000 3800 3000 3000
E17
70 E17 E26Med
100
E17
E26Med
H I D
150
E17
E26Med
ET23.5
100 ET23.5 E39
64918 64915
MC100/U/ET23.5/942 MC150/U/ET23.5/942
C90/E C102/E
20 20
Clear Clear
Universal Universal
24000 24000
94 90
4200 4200
100 100
150
ET23.5
E39
81
E17
BT28
BT37
Watts 50
Bulb E17
Base EX26Med
Ordering Abbreviation MCP50/U/MED/830PB MCP50/C/U/MED/830PB MCP70/U/MED/940PB MCP70/C/U/MED/940PB MCP70/U/MED/830PB MCP70/C/U/MED/830PB MCP100/U/MED/940PB MCP100/C/U/MED/940PB MCP100/U/MED/830PB MCP100/C/U/MED/830PB MCP150/U/MED/830PB MCP150/C/U/MED/830PB MCP200/PS/BU-ONLY/940
Pkg Qty 12 12 12 12 12 12 12 12 12 12 12 12 6 6 6 6 6
Lamp Finish Clear Coated Clear Coated Clear Coated Clear Clear Clear Coated Clear Coated Clear Clear Coated Clear Coated
Operating Position Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal BU 15 BU 15 BU 15 BU 15 BU 15
CRI 88 88 93 93 88 88 93 90 88 88 88 88 90 94 94 88 88
CCT (K) 3000 2900 4000 3800 3000 3000 4000 4000 3000 3000 3000 3000 4200 4200 4000 4000 3900
70
E17
EX26Med
64193 64194
H I D
100 E17 EX26Med
64741 64742
200
BT28
250
BT28
320
BT37
EX39Excl Mogul
64834 64851
Lamps between 175W and 400W operating on ballasts having a sustaining voltage less than 270V, lamp life may be significantly reduced. 1 The first letter of the ANSI code represents the lamp type; C for ceramic metal halide and M for quartz metal halide. The numbers following the lamp type refer to the electrical characteristics required by the ballast to start and operate the lamp reliably. Ceramic, C, or quartz, M lamps with the same electrical characteristic number will operate on the same ballast (per ANSI C78.380-2007). For example, a 150W ceramic lamp with a C102 designation will operate on a 150W metal halide ballast with an M102 designation and vice versa. 2 Preliminary data, visit www.sylvania.com for latest rating.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
82
ED17
ED28
ET23.5
Watts 70
Bulb E17
Base E26Med
Pkg Qty 12 12 12 12 12 12 12 12 6
Lamp Finish Clear Coated Clear Coated Clear Coated Clear Coated Clear
Approx Lumens Initial (Mean) 5600 (3300) 5400 (3000) 8500 (4675) 8000 (4400) 14000 (11000) 12750 (9300) 17500 (12800) 16600 (12500) 14,400V (10,000V) 12,800H (8,300H) 17500 (12800) 16600 (12500) 19000 (13300) 19000 (13500) 18000 (12800) 21000V (15400V) 18000H (11000H) 23000 (17000) 21500 (15500)
CRI 65 65 65 68 65 70 65 70 65
CCT (K) 4000 3800 4000 3650 4300 4000 4000 3700 4000
100
E17
E26Med
64818 64894
150
E17
E26Med
64785 64892
H I D
175
ED17
E26Med
64171 64170
ED28
E39Mogul
64319
MS175/PS/BU-ONLY MS175/C/PS/BU-ONLY
M152/E M152/E
12 12 12 6 6 6
BU 15 BU 15 BU 15 BU 15 BU 15 Universal
65 70 65 65 70 65
100 95 95 95 90 88 76
BT28
E39Mogul
250
BT28
E39Mogul
64320
64578 64617
MS250/PS/BU-ONLY MS250/C/PS/BU-ONLY
M153/E M153/E
6 6
Clear Coated
BU 15 BU 15
200001 200001
65 70
4200 3600
92 86
Lamps between 175W and 400W operating on ballasts having a sustaining voltage less than 270V, lamp life may be significantly reduced. Lamps > 400W operating on ballasts having a sustaining voltage less than 310V, lamp life may be significantly reduced. 1 20,000 average rated life based on 10 hrs/start. 30,000 average rated life based on 120 hrs/start.
83
BT28
BT37
Watts 320
Bulb BT28
Base E39Mogul
Pkg Qty 6
CRI 65
64646
MS320/C/PS/BU-HOR
M154/E
Coated
BU-HOR
20000V 15000H
400
BT28
E39Mogul
64188
M400/PS/U/BT28
M155/S
Clear
Universal
20000V 15000H
H I D
64191 64189
BT37 E39Mogul
6 6 6
BD 15 BU 15 Universal
64321
64525 64527
750 BT37 E39Mogul
6 6 6
BU 15 BU 15 BU-HOR
64787
64822
MS750/C/PS/BU-HOR/BT37 M149/E
Coated
BU-HOR
20000V 9000H
1000
BT37
E39Mogul
64351
M1000/PS/U/BT37
M141/E
Clear
Universal
15000V 9000H
Lamps between 175W to 400W operated on ballasts having a sustaining voltage less than 270V, lamp life may be significantly reduced. Lamps > 400W operating on ballasts having a sustaining voltage less than 310V, lamp life may be significantly reduced. 1 20,000 average rated life based on 10 hrs/start. 30,000 average rated life based on 120 hrs/start.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
84
E17
BT28
BT37
Watts 50
Bulb E17
Base EX26Med
Ordering Abbreviation MP50/U/MED MP50/C/U/MED MP70/U/MED MP70/C/U/MED MPD70/U/MED/840 MPD70/C/U/MED/840 MP100/U/MED MP100/C/U/MED MPD100/U/MED/840 MPD100/C/U/MED/840 MP150/U/MED MP150/C/U/MED MPD150/U/MED/840 MPD150/C/U/MED/840 MP250/PS/BU-ONLY MP250/C/PS/BU-ONLY
Pkg Qty 20 20 20 20 20 20 20 20 20 20 20 20 20 20 6 6 6
Lamp Finish Clear Coated Clear Coated Clear Coated Clear Coated Clear Coated Clear Coated Clear Coated Clear Coated Clear
Operating Position Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal BU 15 BU 15 BU 15
CRI 70 70 75 75 80 82 75 75 82 82 75 75 88 88 65 70 65
CCT (K) 3000 2900 3000 2900 4200 4000 3000 2900 4200 4000 3000 2900 4200 4000 4000 4000 3800 3600
70
E17
EX26Med
H I D
100
E17
EX26Med
150
E17
EX26Med
250
BT28
EX39Excl Mogul
64789 64790
320/350 BT28
EX39Excl Mogul
64391
64349
Coated
BU 15
20000
70
3600 3600
350/400 BT37
EX39Excl Mogul
64769
MP350/400/PS/BU-ONLY
M131/O M155/O
Clear
BU 15
20000
65
3700 3500
64770
MP350/400/C/PS/BU-ONLY
M131/O M155/O
Coated
BU 15
20000
70
3500 3300
85
PAR38
ED17
BT28
BT37
BT56
Watts 70
Bulb PAR38
CCT (K) 3200 3200 3200 3000 3000 3000 3200 3200 3200
100
PAR38
E26Med Skt
H I D
150
PAR38
E26Med Skt
MP150PAR38/U/VWFL65/ECO M102/O
Lamps between 175W and 400W operating on ballasts having a sustaining voltage less than 270V, lamp life may be significantly reduced. 1 Lamps with an E26 medium skirt base are not compatible with exclusionary medium sockets.
Watts 175
Bulb ED17
Base EX26Med
Ordering Abbreviation MP175/BU-ONLY/MED MP175/BU-ONLY MP175/C/BU-ONLY MP250/BU-ONLY MP250/C/BU-ONLY MP400/BU-ONLY MP400/C/BU-ONLY MP400/BD-ONLY MP1000/BU-ONLY MP1000/C/BU-ONLY
Pkg Qty 20 6 6 6 6 6 6 6 6 6
Lamp Finish Clear Clear Coated Clear Coated Clear Coated Clear Clear Coated
Operating Position BU 15 BU 15 BU 15 BU 15 BU 15 BU 15 BU 15 BD 15 BU 15 BU 15
CRI 65 65 70 65 70 65 70 65 65 70
CCT (K) 3600 4000 3800 4000 3800 3600 3400 3600 3500 3200
BT28
EX39Excl Mogul
250
BT28
EX39Excl Mogul
64404 64405
400
BT37
EX39Excl Mogul
1000
BT56
EX39Excl Mogul
64714 64716
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
86
BT28
BT37
BT56
Watts 175
Bulb BT28
Base E39POM
Ordering Abbreviation MS175/HOR MS250/HOR MS400/HOR/BT28 MS400/HOR MS400/BU-ONLY MS400/C/BU-ONLY MS1000/BU-ONLY MS1000/BD-ONLY
Pkg Qty 6 6 6 6 6 6 6 6
Lamp Finish Clear Clear Clear Clear Clear Coated Clear Clear
CRI 65 65 65 65 65 70 65 65
CCT (K) 4200 4200 4200 4200 4000 3600 4000 4000
250
BT28
E39POM
400
BT28
E39POM
BT37
E39POM
E39Mogul
H I D
1000
BT56
E39Mogul
64435 64436
Watts 150
Bulb BT28
Base E39Mogul
Pkg Qty 6
Approx Lumens Initial (Mean) 13000V (7500V) 12000H (8500H) 36000V (23500V) 30000H (19000H) 36000V (22500V) 30000H (19000H) 35000 (23500) 34000 (22500) 103000V (80000V) 90000H (64000H)
CRI 65
64655
MS360/SS/BU-HOR
M165/S
Clear
BU-HOR
20000V 15000H
65
4000
100 83
64656
MS360/C/SS/BU-HOR
M165/S
Coated
BU-HOR
20000V 15000H
70
3600
100 83
64737 64738
950 BT56 E39Mogul
6 6 6
BU 15 BU 15 Universal
65 70 65
97 94 108 95
64850
150W lamps operate on M57 or M107 ballasts. 360W lamps operate on M59 or M165 ballasts. 950W lamps operate on M47 or M176 ballasts.
87
E17
BT28
ET18
BT37
BT56
Watts 175
Bulb E17
Base E26Med
Pkg Qty 20
Approx Lumens Initial (Mean) 14400V (9300V) 12800H (9300H) 13000V (8400V) 11080H (8400H) 14400V (9300V) 12800H (9300H) 14000V (8400V) 12000H (8400H) 22000V (17500V) 20000H (13500H) 22000V (15000V) 20000H (13000H) 21500V (17000V) 19500H (14000H) 36000V (25000V) 33000H (21500H) 36000V (25500V) 32000H (20500H) 36000V (22500V) 32000H (19000H) 36000V (23500V) 32000H (20500H) 36000V (22500V) 32000H (20500H)
CRI 65
70
3600
74 63
64471
M175/U
M57/E
Clear
Universal
10000V 7500H
65
4200
82 73
H I D
64472
M175/C/U
M57/E
Coated
Universal
10000V 7500H
70
3800
80 69
250
ET18
E39Mogul
64474
M250/U/ET18
M58/E
10
Clear
Universal
10000V 10000H
65
4000
88 80
BT28
E39Mogul
64457
M250/U
M58/E
Clear
Universal
10000V 7500H
65
4200
88 80
64458
M250/C/U
M58/E
Coated
Universal
10000V 7500H
70
3800
86 78
400
ET18
E39Mogul
64575
M400/U/ET18
M59/E
10
Clear
Universal
20000V 15000H
65
4000
90 83
BT28
E39Mogul
64488
M400/U/BT28
M59/E
Clear
Universal
20000V 15000H
65
4000
90 80
64489
M400/C/U/BT28
M59/E
Coated
Universal
20000V 15000H
70
3600
90 80
BT37
E39Mogul
64490
M400/U
M59/S
Clear
Universal
20000V 15000H
65
4000
90 80
64492
M400/C/U
M59/S
Coated
Universal
20000V 15000H
70
3700
90 80
20,000 average rated life based on 10 hrs/start. 30,000 average rated life based on 120 hrs/start. Lumens will be lower for operating positions other than base up. See lumen tilt factor curve in the Metal Halide Specification Guide (HID017).
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
88
BT56
Watts 1000
Bulb BT37
Base E39Mogul
Pkg Qty 6
Approx Lumens Initial (Mean) 110000V (96000V) 107800H (86300H) 110000V (86000V) 107800H (86000H) 107000V (80000V) 101600H (80700H) 170000V (140000V) 153000H (127400H)
CRI 65
64468
M1000/U
M47/S
Clear
Universal
18000V 12000H
65
4000
110 108
1000
BT56
E39Mogul
64470
M1000/C/U
M47/S
Coated
Universal
18000V 12000H
70
3400
107 102
1500
BT56
E39Mogul
64431
M1500/BU-HOR
M48/E
Clear
BU-HOR
3000
70
4000
113 102
H I D
Published rated life based on 5 hours per start. Life rating will increase to 6,000 hours if operated for at least 10 hours per start in the base up position. Lumens will be lower for operating positions other than base up. See lumen tilt factor curve in the Metal Halide Specification Guide (HID017).
89
E17
ET18
ET23.5
E25
Watts 50
Bulb ET23.5
Base E39Mogul
Product Number 67607 67322 67497 67323 67559 67494 67495 67572 67660 67312 67316
Ordering Abbreviation LU50/PLUS/ECO LU70/PLUS/MED LU70/PLUS/ECO LU100/PLUS/MED LU100/PLUS/ECO LU150/55/PLUS/ECO LU200/PLUS/ECO LU250/PLUS/ECO LU310/PLUS/ECO LU400/PLUS/ECO LU1000/PLUS
Pkg Qty 20 20 20 20 20 20 20 20 20 20 6
Lamp Finish Clear Clear Clear Clear Clear Clear Clear Clear Clear Clear Clear
Operating Position Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal
CRI 22 22 22 22 22 22 22 22 22 22 22
CCT (K) 1900 1900 1900 2100 2100 2100 2100 2100 2100 2100 2100
70
E17
E26Medium
ET23.5
E39Mogul
100
E17
E26Medium
H I D
ET23.5
E39Mogul
150
ET23.5
E39Mogul
200
ET18
E39Mogul
250
ET18
E39Mogul
310
ET18
E39Mogul
400
ET18
E39Mogul
1000
1 2
E25
E39Mogul
LU150/100 (100V) and LU150/55 (55V) lamps are not interchangeable. Mean lumens are measured on ANSI reference circuits at rated wattage at 40% of average rated life except for those lamps with a + next to their life rating; these lamps are measured at 50% of average rated life. 3 Use with 5000V pulse rated sockets only. 4 Lamp lumen maintenance is 90% at 30,000 hours.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
90
ET23.5
ET18
E25
Watts 70
Bulb ET23.5
Base E39Mogul
Pkg Qty 20 20 20 20 20 20 6
CRI 22 22 22 22 22 22 22
100
ET23.5
E39Mogul
150
ET23.5
E39Mogul
200
ET18
E39Mogul
250
ET18
E39Mogul
400
ET18
E39Mogul
H I D
1000
1 2
E25
E39Mogul
LU150/100 (100V) and LU150/55 (55V) lamps are not interchangeable. Standby (instant restrike) feature not guaranteed beyond 24,000 operating hours. 3 Use with 5000V pulse rated sockets only.
PLANTASTAR Lamps
PLANT GROWTH / HORTICULTURE
See product information bulletin (HID044) for product details ANSI Code/ Fixture Req. S52/O Avg Rated Life (hrs) 24000 Approx Lumens Initial (Mean) 130000 (124000) Lamp Efficacy (LPW) 130
Watts 1000
Bulb E25
Base E39Mogul
Pkg Qty 6
CRI 22
91
ET23.5
BT28
ET18
BT37
T7, RX7s
E25
Watts
Bulb
Base
Ordering Abbreviation LU50/ECO LU50/D LU70/ECO LU70/D LU100/ECO LU100/D LU150/55/ECO LU150/55/D LU150/100 LU200/ECO LU250/ECO LU250/D LU310/ECO LU400/ECO LU400/D LU400T7/RSC LU750 LU1000/ECO
Pkg Qty 20 20 20 20 20 20 20 20 10 20 20 10 20 20 10 10 6 6
Lamp Finish Clear Coated Clear Coated Clear Coated Clear Coated Clear Clear Clear Coated Clear Clear Coated Clear Clear Clear
Operating Position Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal Horizontal Universal Universal
CRI 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 21 22 22
CCT (K) 1900 1900 1900 1900 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100
E39 Mogul
50 ET23.5 E39Mogul
70
ET23.5
E39Mogul
67512 67513
H I D
100
ET23.5
E39Mogul
67514 67515
150
ET23.5
E39Mogul
67516 67517
BT28
E39Mogul
67518 67576 67578 67521 67580 67533 67524 67527 67547 67307
200
ET18
E39Mogul
250
ET18
E39Mogul
BT28
E39Mogul
310
ET18
E39Mogul
400
ET18
E39Mogul
BT37
E39Mogul
T7
RX7s RSC
750
BT37
E39Mogul
1000
1 2
E25
E39Mogul
LU150/100 (100V) and LU150/55 (55V) lamps are not interchangeable. Mean lumens are measured on ANSI reference circuits at rated wattage at 40% of average rated life except for those lamps with a + next to their life rating; these lamps are measured at 50% of average rated life. 3 Use with 5000V pulse rated sockets only.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
92
E17
Watts
Bulb
Base
Ordering Abbreviation LU35/MED LU35/D/MED LU50/MED LU50/D/MED LU70/MED LU70/D/MED LU100/MED LU100/D/MED LU150/55/MED LU150/55/D/MED
Pkg Qty 20 20 20 20 20 20 20 20 20 20
Lamp Finish Clear Coated Clear Coated Clear Coated Clear Coated Clear Coated
Operating Position Universal Universal Universal Universal Universal Universal Universal Universal Universal Universal
CRI 22 22 21 22 22 22 22 22 22 22
CCT (K) 1900 1900 1900 1900 1900 1900 2100 2100 2100 2100
E26 Medium
35 E17 E26Medium
50
E17
E26Medium
67502 67503
70
E17
E26Medium
67504 67505
H I D
100
E17
E26Medium
67506 67507
150
E17
E26Medium
67508 67509
1 2
LU150/100 (100V) and LU150/55 (55V) lamps are not interchangeable. Mean lumens are measured on ANSI reference circuits at rated wattage at 40% of average rated life except for those lamps with a + next to their life rating; these lamps are measured at 50% of average rated life.
93
R30
T7.5 HQI
Watts 1500
Bulb T7
Pkg Qty 10 10 10 10
CRI 65 65 65 65
T8
2000
T8
T9
H I D
Use in equipment where gasket material is protected from all lamp radiation. Use with 4-5kV igniter. For use where seal temperature does not exceed 350C. 1 Consult your OSRAM SYLVANIA Lighting Representative for lamp/ballast compatibility.
Watts 150
Bulb R30
Pkg Qty 12
CRI 85
Efficacy (LPW) 73
Watts 150
Bulb T7.5
Base g12
Pkg Qty 12
CRI 85
Efficacy (LPW) 87
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
94
E17
PAR38
ET23.5
ED37, ED28
BT56
T17, T21
Watts 75
Bulb E17
Base E26Med
Ordering Abbreviation H43AV-75/DX H38AV-100/DX H44gS-100SP H44gS-100/MDSKSP H38JA-100/DX H39KB-175 H39KC-175/DX H37KC-250/DX H33CD-400 H33gL-400/DX H36gW-1000/DX
Beam Type
Beam Angle
Coated Universal 16000+ Coated Universal 18000+ Universal Universal 16000 16000
100
E17
E26Med
PAR38
ADMedSkt
E26Med Skt
ET23.5
E39Mogul
175
ED28
E39Mogul
H I D
250
ED28
E39Mogul
400
ED37
E39Mogul
1000
BT56
E39Mogul
69331
Mean lumens are measured on ANSI reference circuits at rated wattage at 40% of average rated life except for those lamps with a + next to their life rating; these lamps are measured at 50% of average rated life.
Watts 18
Bulb T17
Base BY22d
Ordering Abbreviation SOX18 SOX35 Plus SOX55 SOX90 Plus SOX135 Plus SOX1806PK
Pkg Qty 12 12 12 12 12 6
Lamp Operating Finish Position Clear Clear Clear Clear Clear Clear BU BU BU HOR HOR HOR
35
T17
BY22d
55
T17
BY22d
90
T21
BY22d
135
T21
BY22d
180
T21
BY22d
95
H I D
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
96
H I D
97
H I D
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
98
H I D
M150/SS/U/BT28 MS360/SS/BU-HOR MS360/BU/EW MS360/C/SS/BU-HOR MS360/C/BU/EW MSP360/SS/BU-ONLY MP360BU/EW MSP360/C/SS/BU-ONLY MP360/C/BU/EW M950/SS/U/BT56 METALARC STANDARD Probe Start Metal Halide Lamps M175/U/MED M175/C/U/MED M175/U M175/C/U M250/U/ET18 M250/U M250/C/U M400/U/ET18 M400/U/BT28 M400/C/U/BT28 M400/U M400/C/U M1000/U/BT37 M1000/U M1000/C/U M1500/BU-HOR MH175/U/M MH175/C/U/M MH175/U MH175/C/U MH250/U MH250/C/U MH400/U/ED28 MH400/U MH400/C/U MH1000/U/BT37 MH1000/U MH1000/C/U
99
H I D
LU70/SBY LU100/SBY LU150/55/SBY LU200/100/SBY LU250/SBY LU400/SBY LU1000/SBY PLANTASTAR High Pressure Sodium Lamps
LU1000/PLANTASTAR C1000S52/AGROLITE XT LUMALUX STANDARD and LUMALUX ECOLOGIC High Pressure Sodium Lamps LU50/ECO LU50/D LU70/ECO LU70/D LU100/ECO LU100/D LU150/55/ECO LU150/55/D LU150/100 LU200/ECO LU250/ECO LU250/D LU310/ECO LU400/ECO LU400/D LU400T7/RSC LU750 LU1000/ECO LU35/MED LU35/D/MED LU50/MED LU50/D/MED LU70/MED LU70/D/MED LU100/MED LU100/D/MED LU150/55/MED LU150/55/D/MED C50S68/ALTO C50S68/D/ALTO C70S62/ALTO C100S54/ALTO C150S55/ALTO C150S56/ALTO C200S66/ALTO C250S50/ALTO C400S51/ALTO C1000S52/ALTO C35S76/M C35S76/D/M C50S68/M C50S68/D/M C70S62/M C70S62/D/M C100S54/M C100S54/D/M C150S55/M C150S55/D/M
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
100
H I D
101
OPEN FIXTURE RATED, METALARC POWERBALL EL INTEGRATED PAR30LN AND PAR38, O-TYPE LAMP
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. ULTRAVIOLET RADIATION EXPOSURE WARNING: This lamp can cause serious skin burns and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes, unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms to the following federal regulations: USA: 21 CFR 1040.30 and CANADA: SOR/80-381.
H I D
II. RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube. Metal Halide arc-tubes operate at high pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. III. LAMP OPERATING INSTRUCTIONS CAUTION: TO REDUCE THE RISKS OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC TUBE RUPTURE THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED: 1. 2. 3. 4. 5. 6. 7. 8. 9. Re-lamp fixture at or before the end of rated life. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture. (See catalog for rated life.) Only operate with compatible fixture at 120V input. This lamp is not intended for use with emergency fixtures or emergency exit lights. Do not operate with an external ballast as ballast is integrated into the lamp. Do not use with dimmers. Do not use on electronic timers, photocells, lighted switches or any other switches that do not meet UL20 Sec. 7.6.15. Before lamp installation or replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards. Do not use lamp if lens, reflector or housing is visibly damaged. Do not use in totally enclosed, recessed fixture. Protect lamp, lamp socket and wiring against moisture, corrosive atmosphere and excessive heat.
10. Suitable for dry and damp locations. Risk of electric shock Do not use where directly exposed to water. 11. Time should be allowed for lamp color to stabilize when turned on for the first time. All lamp ratings are based on 100 hours of operation. Movement or vibration may cause variation in color and appearance. 12. Lamps may require 10-15 minutes to re-light if there is a loss of power to the socket. 13. Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See Product Safety Data Sheet for further details. 14. This product complies with the requirements of FCC 47 CFR 18 non-consumer. This product may cause interference with radios, televisions, wireless telephones and remote controls. If interference occurs, move the product away from these devices or plug into a different outlet. Do not install this near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45-30 MHz. For additional product information, call 1-800-LIGHTBULB (1-800-544-4828). 15. This Class A RFLD complies with the Canadian standard ICES-005. IV. NOTES: 1. 2. This lamp is intended for use in open fixtures since it was designed to contain a ruptured arc-tube and thereby minimize the resultant risks of personal injury, property damage, burns and fire. This lamp contains an arc tube with a fill gas containing less than 10 nCi of Kr-85 and is distributed by OSRAM SYLVANIA Products Inc. 100 Endicott St. Danvers, MA 01923.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
102
ENCLOSED FIXTURE RATED, METALARC POWERBALL CERAMIC TUBULAR SINGLE- AND DOUBLE-ENDED LAMPS WITH G12, G8.5, G6.5 & RX7S BASES, UV-FILTER OUTER JACKET, E-TYPE LAMP ANSI Luminaire Code E ENCLOSED FIXTURE
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Metal Halide lamp is constructed of a UV-attenuating outer quartz bulb with an internal ceramic arc tube. Metal Halide arc tubes operate at high pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc tube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. TO REDUCE THESE RISKS: 1. 2. 3. 4. 5. 6. 7. 8. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2192F, 1200C for a ceramic arc tube and 2012F, 1100C for quartz). If you are uncertain, contact your fixture manufacturer. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.) Only operate lamp in designated operating positions. (See catalog for illustration.) Lamp must be turned off for a minimum of fifteen minutes at least once a week. Never expose operating lamp to moisture (such as rain, sleet or snow). Replace lamp if outer glass bulb is scratched, cracked or damaged in any way. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition. Replace lamp at or before the end of rated life. (See catalog for rated life.)
H I D
II. ELECTRICAL SHOCK AND BURN HAzARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled. III. ULTRAVIOLET RADIATION EXPOSURE: WARNING: This lamp can cause serious skin burns and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms to the following federal regulations: USA: 21 CFR 1040.30 and CANADA: SOR/80-381. IV. LAMP INSTALLATION: 1. Ensure that lamp is securely seated in the socket. 2. If lamp is touched with bare hands, clean fingerprints off with alcohol and wipe dry with clean, lint-free cloth. 3. All sockets must be rated to withstand the maximum pulse voltage output of the ballast. 4. Never install the lamp into an ordinary household socket or a fixture intended for tungsten halogen lamps. V. BROKEN ARC TUBE: Take care in handling and disposing of this lamp. If arc tube is broken, avoid skin contact with any of the contents and fragments. See Product Safety Data Sheet for further details.
103
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Metal Halide lamp is constructed of a UV-attenuating outer quartz bulb with an internal arc-tube. Metal Halide arc-tubes operate at high pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arctube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. TO REDUCE THESE RISKS: 1. 2. 3. 4. 5. 6. 7. 8. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2192F, 1200C for a ceramic arc tube and 2012F, 1100C for quartz). If you are uncertain, contact your fixture manufacturer. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.) Only operate lamp in designated operating positions. (See catalog for illustration.) Lamp must be turned off for a minimum of fifteen minutes at least once a week. Never expose an operating lamp to moisture (such as rain, sleet or snow). Replace lamp if outer glass bulb is scratched, cracked or damaged in any way. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition. Replace lamp at or before the end of rated life. (See catalog for rated life.)
H I D
FOR APPLICATIONS WHERE AN ADDITIONAL MEASURE OF SAFETY IS DESIRED, LAMPS USING AN INTERNAL SHIELD DESIGNED TO CONTAIN AN ARC-TUBE RUPTURE ARE AVAILABLE. II. ELECTRICAL SHOCK AND BURN HAzARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled. III. ULTRAVIOLET RADIATION EXPOSURE: WARNING: This lamp can cause serious skin burns and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms to the following federal regulations: USA: 21 CFR 1040.30 and CANADA: SOR/80-381. IV. LAMP INSTALLATION: 1. Screw lamp firmly but not forcibly into socket to avoid breakage. 2. All horizontal lamps with position oriented mogul (POM) bases (with locating pin) require a POM socket. Do not remove pin from base. 3. All pulse start lamps require a socket rated to withstand a 4000 volt pulse. 4. Never install the lamp into an ordinary household socket. V. BROKEN ARC TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See Product Safety Data Sheet for further details.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
104
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube. Metal Halide arc-tubes operate at high pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. TO REDUCE THESE RISKS: 1. 2. 3. 4. 5. 6. 7. Only operate with compatible ballast and fixture. (See catalog for specific information.) Only operate lamp in designated operating positions. (See catalog for illustration.) Lamp must be turned off for a minimum of fifteen minutes at least once a week. Never expose operating lamp to moisture (such as rain, sleet or snow). Replace lamp if outer glass bulb is scratched, cracked or damaged in any way. Electrically insulate any metal support in contact with the outer glass bulb to avoid glass decomposition. Replace lamp at or before the end of rated life. (See catalog for rated life.)
H I D
This lamp is intended for use in open fixtures since it contains a special shield which was designed to contain a ruptured arc-tube and thereby minimize the resultant risks of personal injury, property damage, burns and fire. In applications where an additional measure of safety is desired, an enclosed fixture may be used with a lens/diffuser material able to contain hot lamp fragments (up to 2192F, 1200C for a ceramic arc tube and 2012F, 1100C for quartz). If you are uncertain, contact your fixture manufacturer. II. ELECTRICAL SHOCK AND BURN HAzARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled. III. ULTRAVIOLET RADIATION EXPOSURE: WARNING: This lamp can cause serious skin burns and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms to the following federal regulations: USA: 21 CFR 1040.30 and CANADA: SOR/80-381. IV. LAMP INSTALLATION: 1. Screw lamp firmly but not forcibly into socket to avoid breakage. 2. All pulse start lamps require a socket rated to withstand a 4000 volt pulse. 3. Never install the lamp into an ordinary household socket. V. BROKEN ARC TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See Product Safety Data Sheet for further details.
105
ANSI Luminaire Code S ENCLOSED FIXTURE/Open if meets requirement of Paragraph I.1 below
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Metal Halide lamp is constructed of an outer glass bulb with an internal arc-tube. Metal Halide arc-tubes operate at high pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. TO REDUCE THESE RISKS: 1. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2012F, 1100C). If you are uncertain, contact your fixture manufacturer. When operated within 15 of vertical, this lamp may be operated in an open fixture PROVIDED THE INSTALLATION IS NOT NEAR PEOPLE OR FLAMMABLE OR COMBUSTIBLE MATERIAL. 2. 3. 4. 5. 6. 7. 8. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.) Only operate lamp in designated operating positions. (See catalog for illustration.) Lamp must be turned off for a minimum of fifteen minutes at least once a week. Never expose an operating lamp to moisture (such as rain, sleet or snow). Replace lamp if outer glass bulb is scratched, cracked or damaged in any way. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition. Replace lamp at or before the end of rated life. (See catalog for rated life.)
H I D
FOR APPLICATIONS WHERE AN ADDITIONAL MEASURE OF SAFETY IS DESIRED, LAMPS USING AN INTERNAL SHIELD DESIGNED TO CONTAIN AN ARC-TUBE RUPTURE ARE AVAILABLE. II. ELECTRICAL SHOCK AND BURN HAzARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled. III. ULTRAVIOLET RADIATION EXPOSURE: WARNING: This lamp can cause serious skin burns and eye inflammation from shortwave ultraviolet radiation if the outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available. This product conforms to the following federal regulations: USA: 21 CFR 1040.30 and CANADA: SOR/80-381. IV. LAMP INSTALLATION: 1. Screw lamp firmly but not forcibly into socket to avoid breakage. 2. All horizontal lamps with position oriented mogul (POM) bases (with locating pin) require a POM socket. Do not remove pin from base. 3. All pulse start lamps require a socket rated to withstand a 4000 volt pulse. 4. Never install the lamp into an ordinary household socket. V. BROKEN ARC TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See Product Safety Data Sheet for further details.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
106
ANSI Luminaire Code F ENCLOSED FIXTURE with UV Filter and lens interlock required
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Metal Halide lamp is constructed with a quartz arc-tube which operates at high pressure and at very high temperatures. The arc-tube can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication resulting in the discharge of glass fragments and extremely hot particles. In the event of such rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. TO REDUCE THESE RISKS: 1. 2. 3. 4. 5. 6. 7. 8. Only operate lamp in an enclosed fixture with a lens/diffuser material able to contain hot lamp fragments (up to 2012F, 1100C). If you are uncertain contact your fixture manufacturer. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.) Only operate lamp in horizontal position. (See page 75.) Lamp must be turned off for a minimum of fifteen minutes at least once a week. Never expose operating lamp to moisture (such as rain, sleet or snow). Replace lamp if bulb is scratched, cracked or damaged in any way. Keep all metals at least 3 inches from the body of the arc tube to avoid glass decomposition. Replace lamp at or before the end of rated life. (See catalog for rated life.)
H I D
II. ULTRAVIOLET RADIATION HAzARD: THIS LAMP EMITS ULTRAVIOLET (UV) POWER DURING OPERATION AND IS IN RISK GROUP 3 PER ANSI-IESNA Rp-27.3-96. THIS LAMP CAN CAUSE SERIOUS SKIN BURNS AND EYE INJURY FROM SHORTWAVE ULTRAVIOLET RADIATION. IT MUST BE OPERATED IN AN ENCLOSED FIXTURE WHICH FILTERS OUT THE HARMFUL SHORTWAVE ULTRAVIOLET RADIATION. IF YOU ARE UNCERTAIN, CONTACT YOUR FIXTURE MANUFACTURER. A power interlock device is required to automatically turn off the lamp if the fixture assembly is opened. It is strongly recommended that a power interlock device also turn off power to the lamp if the fixture lens is broken. If the fixture lens breaks and the lamp remains on, turn off power immediately and repair before reenergizing. This lamp is to be used ONLY in a fixture specifically designed for use with this lamp and recommended for its use by the equipment manufacturer. III. ELECTRICAL SHOCK AND BURN HAzARD: Do not remove or insert lamp while power is on. Allow lamp to cool before removing. IV. LAMP INSTALLATION: Do not remove lamp from package until ready for use and then handle only with clean cotton gloves. If lamp is handled, fingerprints, grease or oils may be removed from the bulb by wiping with alcohol. This will remove materials which cause whitish spotting (devitrification) and premature lamp failure. Dry lamp carefully with clean cotton cloth. 1. Install lamp without undue pressure. 2. Ensure that lamp electrical connections are secure and nothing is touching bulb. 3. All seal gaskets and wire insulation must be shielded from the UV radiation produced by this lamp. 4. Fixture wiring must have a temperature rating of 250C and a minimum voltage rating of 600V RMS for all lamps except the 1500T7 lamp which must have a voltage rating of 1500V RMS. 5. For maximum performance, all double-ended lamps must be operated with the arc-tube tip up. V. BROKEN ARC TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See Product Safety Data Sheet for further details.
107
LUMALUX, LUMALUX / ECO, LUMALUX PLUS / ECO AND LUMALUX STANDBY LAMPS ANSI LUMINAIRE Code F ENCLOSED FIXTURE with UV Filter and lens interlock required
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. OPERATE WITH COMPATIBLE BALLAST AND FIXTURE ONLY: This lamp must be operated in a fixture and ballast which has an ANSI designation identical to that found on the lamp outer glass bulb. (with the exception of the LU/PLUS on Cooper ignitor 220C173G11, which may have compatibility issues).
H I D
II. ELECTRICAL SHOCK AND BURN HAzARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled. III. INSTALLATION AND OPERATING INSTRUCTIONS: See catalog for specific operating parameters. 1. A specially designed socket which is electrically rated to withstand a 4000 volt pulse is required for all High Pressure Sodium lamps except for the 750 and 1000 watt lamps which require a socket rated to withstand a 5000 volt pulse. 2. These lamps have a vacuum jacket and may implode if broken. For added safety, wear safety glasses and gloves when installing or removing lamps. 3. To avoid burn injury, allow lamp to cool before removing from fixture. 4. Screw lamp firmly but not forcibly into socket to avoid breakage. 5. Replace lamps at or before end of rated life. (See catalog for rated life.) 6. Never install it into an ordinary household socket. 7. This lamp may be operated in any position. IV. PROPER CARE AND MAINTENANCE: To reduce the possibility of a rupture and premature lamp failure: 1. Do not use with luminaires which would cause an excessive increase in arc-tube operating voltage. 2. Do not expose operating lamp to moisture (such as rain, sleet or snow). 3. Replace lamp if outer glass bulb has been scratched, cracked or damaged in any way. 4. Electrically insulate any metal support in contact with the outer glass bulb to avoid glass decomposition. V. BROKEN ARC TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See Product Safety Data Sheet for further details.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
108
LUMALUX DOUBLE-ENDED QUARTz JACKETED LAMPS ANSI LUMINAIRE Code F ENCLOSED FIXTURE with UV Filter and lens interlock required
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. OPERATE WITH COMPATIBLE BALLAST AND FIXTURE ONLY: This lamp must be operated in a fixture and ballast which has an ANSI designation identical to that found on the lamp outer glass bulb.
II. ULTRAVIOLET RADIATION HAzARD: THIS LAMP EMITS ULTRAVIOLET (UV) POWER DURING OPERATION AND IS IN RISK GROUP 2 PER ANSI-IESNA Rp-27.3-96. THIS LAMP CAN CAUSE SERIOUS SKIN BURNS AND EYE INJURY FROM SHORTWAVE ULTRAVIOLET RADIATION. IT MUST BE OPERATED IN AN ENCLOSED FIXTURE WHICH FILTERS OUT THE HARMFUL SHORTWAVE ULTRAVIOLET RADIATION. IF YOU ARE UNCERTAIN, CONTACT YOUR FIXTURE MANUFACTURER. A power interlock device is required to automatically turn off the lamp if the fixture assembly is opened. It is strongly recommended that a power interlock device also turn off power to the lamp if the fixture lens is broken. If the fixture lens breaks and the lamp remains on, turn off power immediately and repair before reenergizing. This lamp is to be used ONLY in a fixture specifically designed for use with this lamp and recommended for its use by the equipment manufacturer. III. ELECTRICAL SHOCK AND BURN HAzARD: Do not remove or insert lamp while power is on. Allow lamp to cool before removing. IV. LAMP INSTALLATION AND FIXTURE: Do not remove lamp from package until ready for use and then handle only with clean cotton gloves. If lamp is handled, fingerprints, grease or oils may be removed from the bulb by wiping with alcohol. This will remove materials which cause whitish spotting (devitrification) and premature lamp failure. Dry lamp carefully with clean cotton cloth. 1. Install lamp without undue pressure. 2. Ensure that lamp electrical connections are secure and nothing is touching bulb. 3. All seal gaskets and wire insulation must be shielded from the UV radiation produced by this lamp. 4. Fixture wiring must have a temperature rating of 250C and a minimum voltage rating of 600V RMS. 5. Never install it into a fixture designed for use with tungsten halogen lamps. 6. Do not expose operating lamp to moisture (such as rain, sleet or snow). 7. Replace lamp if outer glass bulb has been scratched, cracked or damaged in any way. V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See Product Safety Data Sheet for further details.
H I D
109
R
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. RUPTURE RISKS: This Mercury lamp is constructed of an outer glass bulb with an internal arc-tube made of quartz. Mercury arc-tubes operate at high pressure and at very high temperatures and can unexpectedly rupture due to internal causes or external factors such as a ballast failure or misapplication. An arc-tube rupture can burst and shatter the outer glass bulb resulting in the discharge of glass fragments and extremely hot quartz particles. In the event of such rupture, THERE IS A RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE. TO REDUCE THESE RISKS: 1. 2. 3. 4. 5. 6. Only operate lamp with compatible ballast and fixture. (See catalog for specific information.) Fixture lens/diffuser material must be able to contain hot lamp fragments (as high as 1832F, 1000C). If you are uncertain, contact your fixture manufacturer. Never expose an operating lamp to moisture (such as rain, sleet or snow). Replace lamp if outer glass bulb is scratched, cracked or damaged in any way. Electrically insulate any metal support in contact with the outer bulb to avoid glass decomposition. Replace lamp at or before the end of rated life. (See catalog for rated life.)
H I D
II. ELECTRICAL SHOCK AND BURN HAzARD: Do not remove or insert lamp while power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled. III. ULTRAVIOLET RADIATION EXPOSURE: WARNING: THIS LAMP CAN CAUSE SERIOUS SKIN BURNS AND EYE INFLAMMATION FROM SHORTWAVE ULTRAVIOLET RADIATION IF THE OUTER ENVELOPE OF THE LAMP IS BROKEN OR PUNCTURED. DO NOT USE WHERE PEOPLE WILL REMAIN FOR MORE THAN A FEW MINUTES UNLESS ADEQUATE SHIELDING OR OTHER SAFETY PRECAUTIONS ARE USED. LAMPS THAT WILL AUTOMATICALLY EXTINGUISH WHEN THE OUTER ENVELOPE IS BROKEN OR PUNCTURED ARE COMMERCIALLY AVAILABLE. THIS PRODUCT CONFORMS TO THE FOLLOWING FEDERAL REGULATIONS: USA: 21 CFR 1040.30 AND CANADA: SOR/80-381. IV. INSTALLATION: 1. Screw lamp firmly but not forcibly into socket to avoid breakage. 2. To avoid damaging a lamp, never install it into an ordinary household socket. 3. This lamp may be operated in any position. V. BROKEN ARC-TUBE: Take care in handling and disposing of this lamp. If arc-tube is broken, avoid skin contact with any of the contents and fragments. See Product Safety Data Sheet for further details.
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
110
SOX LAMPS
R
THE FOLLOWING INSTRUCTIONS MUST BE COMPLIED WITH TO AVOID RISK OF PERSONAL INJURY, PROPERTY DAMAGE AND POOR LAMP PERFORMANCE.
I. BURNS AND FIRE HAzARD: Sox lamps contain a quantity of sodium which may heat from a reaction with moisture in the air or on the skin if a lamp is broken. Hot sodium will burn spontaneously when exposed to the air. Sodium lamps must be packed, shipped and stored in the wrapping provided to reduce the risk of breakage.
II. IMPLOSION HAzARD: Always wear safety glasses when handling lamp. Low pressure sodium lamps are made of glass and are evacuated and could therefore implode if damaged or handled incorrectly. Replace lamp if outer glass bulb has been scratched, cracked or damaged in any way. To reduce the possibility of a lamp cracking or breaking, do not expose operating lamp to rain, snow or water. III. ELECTRICAL SHOCK AND BURN HAzARD: Do not remove or insert lamp when power is on. If outer glass bulb is broken, shut off power immediately and remove lamp after it has cooled. IV. OPERATE WITH COMPATIBLE BALLAST AND FIXTURE ONLY: This lamp must be operated in a fixture and ballast which was specifically designed for use with this lamp. V. INSTALLATION AND OPERATING INSTRUCTIONS: 1. When operated in other than the base up orientation, single-based SOX lamps from 35 watts to 180 watts must be supported at the end opposite to the base in such a way as to allow for thermal expansion and contraction along the lamp axis. 2. Install lamp firmly but not forcibly into socket to avoid breakage. 3. For maximum system performance, replace lamp at or before end of rated life. (See catalog for rated life.) 4. Only operate lamps in designated operating positions. (See catalog for illustration.) VI. LAMP DISPOSAL: To avoid the risk of personal injury or property damage from sodium reaction when disposing of spent lamps, the following procedure should be followed: 1. Before commencing, operator must be outfitted with appropriate OSHA-approved face mask, gloves and apron. 2. Place no more than 20 lamp(s) in a large, dry container. (Do not exceed one-quarter of the container height.) 3. Break lamp(s) into small pieces inside the container in a dry atmosphere and in a well ventilated area. 4. From a safe distance, carefully pour enough tap water into container to cover all materials. 5. After a few minutes, the reaction of the sodium with the large quantity of water will produce a mild sodium hydroxide solution which may be disposed of in accordance with applicable federal, state and local regulations.
H I D
111
Hg
For weight and measure information, please visit www. sylvania.com For more information about HID lamp warranties, please visit the warranty section of this catalog.
H I D
For the current listing of available products and more complete product information, please visit us at www.sylvania.com Specifications subject to change without notice.
112
Ballast
TABLE OF CONTENTS
the system solution NEMA Premium Electronic Ballast Program QUICKTRONIC High Efficiency T8 Instant Start Systems
114 117 118 122 124 127 128 130 131 131 132 134 136 137 138 141 141 142 144 144 146 158
QUICKTRONIC Professional Series T8 Instant Start Systems QUICKTRONIC High Efficiency T8 PROStart Systems QUICKTRONIC T8 8-foot Instant Start Systems QUICKTRONIC T8 347 Volt Canadian Systems QUICKTRONIC QUICKSTEP T8 & T5HO Bi-Level Dimming Systems
QUICKTRONIC POWERSENSE T8 & T5 Continuous Dimming Systems QUICKTRONIC HELIOS T5HO Continuous (0-10Vdc) Dimming Systems QUICKTRONIC DALI Dimming Systems QUICKTRONIC High Efficiency T5 & T5HO PROStart (Type CC) Systems QUICKTRONIC High Efficiency T5HO PROStart (347-480V) Systems QUICKTRONIC Professional Series T5 & T5HO PROStart (347-480V) Systems QUICKTRONIC Professional Series T5HO PROStart Systems QUICKTRONIC High Efficiency DULUX Systems QUICKTRONIC Professional Series DULUX Systems QUICKTRONIC Metal Halide Systems QUICKTRONIC ICETRON Induction Systems
QUICKTRONIC T2, T12 & T12HO Systems QUICKCROSS Cross Reference Guide Magnetic Fluorescent & High Intensity Discharge Ballasts
www.sylvania.com
QUICKTRONIC High Efficiency The High Efficiency Series features energysaving electronic T8 ballasts that save up to an additional 6% (2 to 5 watts) over standard electronic ballasts. Features also include <10% THD and Universal Voltage. High Efficiency Systems over 90% efficient (maximize energy savings) Up to 60% savings Over 100 LPW (lumens/watt) with OCTRON SUPERSAVER lamps Lowest power T8 Instant Start Systems Same Light, Less Power
QUICKTRONIC Professional Professional Series products incorporate one or more value added features such as <10% THD, PROStart, Instant Start, Universal Voltage, etc. QUICKTRONIC T8 Instant Start <20% THD Products. Universal Voltage (120-277V) Universal voltage models operate from 120-277V, eliminating incorrect line voltage wiring errors and reducing the number of models in inventory by half. Squiggle The sine wave graphic logo of the Electronics & Controls division of OSRAM SYLVANIA signifies the transition from old technology to the high frequency, high efficiency electronic systems of the future. SYLVANIA has officially changed the squiggle to green.
114
High Efficiency DULUX L Systems QHE energy saving FT40DL/25W & FT40DL/28W SUPERSAVER Systems: SAME LIGHT, LESS POWER Universal input voltage (120-277V) QUICKSENSE end of lamp life sensing Auto reset
Banded Packaging New Banded Packaging has replaced the shrink-wrapped product for added benefits: Distributor friendly; easy stocking for individual ballast sales Contractor friendly; easy handling; no tangled wires Reduces waste Easily removable bands
Removable Bands
SUPERSAVER Xtreme Systems New High Efficiency QUICKTRONIC PROStart PSX Universal Voltage ballasts, when combined with OCTRON SUPERSAVER energy saving high performance T8 lamps, provide the lowest power PROStart T8 systems available.
Key System Features: PROStart Xtreme: For frequent switching, longest lamp life Universal input voltage (120-277V) Available in 0.71 ballast factor
115
MULTI-WATT New electronic ballasts that offer the versatility to operate multiple lamp types of various wattages. These multi-watt and multi-lamp models also can vary the number of lamps operated (i.e. 1 or 2 lamps), reducing the amount of ballast types required. Dual Entry CFL Dual entry, color coded connectors located on the side and bottom allow for increased mounting flexibility with one ballast and also increased ease of installation. T5HO HELIOS Dimming Electronic ballast with continuous 100-1% dimming range. They can be controlled by a wide variety of 0-10 volt DC control devices, including daylight sensors, building automation systems and compatible wall box dimming controllers. DALI Digital Dimming DALI digital control technology offers full-range continuous dimming, individual fixture control and feedback. The communications protocol is DALI, an acronym for Digital Addressable Lighting Interface. DALI is the worldwide standard for digital lighting control. PROStart A programmed rapid starting method for fluorescent lamps that achieves up to 100,000 switching cycles which is ideal for use on occupancy sensors. Exclusive lamp warranty for occupancy sensor applications
PENTRON HO New T5 high output fluorescent lamp systems provide almost twice the lumen output of standard lamps and allow new low profile fixtures to be designed. QUICKSENSE The patented end-of-lamp-life sensing technology that helps prevent lamp overheating and established the benchmark for industry recommendations for T5 and smaller diameter lamps. PLUS (High Ballast Factor) Systems T8 lamps are run at higher lumen levels to allow fewer lamps or higher light levels. ICETRON Systems Unique Inductively Coupled Electrodeless Fluorescent Lamp Systems that provide 100,000 hour rated lamp life for use in high maintenance cost areas. Electronic Metal Halide Systems QUICKTRONIC MH features a state of the art electronic design to deliver performance levels unattainable with standard magnetic based lighting systems. Provides energy savings up to 50% compared to magnetic ballasts.
QUICKTRONIC High Efficiency Type CC & Lamp Striation Control (LSC) Models Offer the same energy saving benefits as the High Efficiency QHE ballasts with two additional advantages: Meets UL Type CC (Commercial Cabinet) Rating: New micro-controller circuity reduces arcing caused by loose or improper lamp pin to socket connections. Lamp Striation Control, (LSC): LSC circuitry minimizes lamp striations/ strobing that can occur at lower temperatures and especially in T8 energy saving lamps. (Please consult manufacturers for additional details.)
Key System Features: Lowest power T8 Instant Start Systems Over 100 LPW (lumens/watt) with OCTRON SUPERSAVER lamps Provides 30-50% energy savings when compared to F40T12 Magnetic Systems QHE/SS Systems provide up to 25% savings compared to standard T8 systems Universal input voltage (120-277V) 116
www.sylvania.com
OSRAM SYLVANIA has a variety of high efficiency instant start, programmed rapid start, dimming and bi-level ballasts that comply with the NEMA Premium Electronic Ballast Program. Be sure to look for the NEMA Premium mark on our QUICKTRONIC High Efficiency electronic ballast systems. These systems allow you to meet the increasing demands of the energy efficiency lighting requirements.
117
BEF1 3.12 3.12 3.25 3.55 3.90 1.63 1.63 1.73 1.86 2.05 1.08 1.08 1.15 1.24 1.37 0.82 0.82 0.88 0.93 1.04 3.14 3.14 3.38 3.52 4 1.6 1.6 1.69 1.83 2.05 1.07 1.07 1.14 1.22 1.38 0.82 0.82 0.87 0.93 1.04
E L E C T R O N I C B A L L A S T S
QHE ISL and ISN models above also operate FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W), FBO29/SS (29W) QHE ballasts operate additional T8 lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. Banded Pack, (add -B to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add -PAL to Description).
SYLVANIA OCTRON ECOLOgIC3 fluorescent lamps are designed to satisfy the Federal Toxicity Characteristic Leaching Procedure (TCLP) criteria for classification as nonhazardous waste in most states.* ECOLOgIC3 represents a more comprehensive approach to sustainability encompassing high efficiency, long life and RoHS/TCLP compliance. *Regulations may vary. Check your local and state regulations. NEMA Premium Ballast (NPB) program compliant. The NPB program promotes the use of high efficiency T8 electronic ballasts by meeting or exceeding the Ballast Efficiency Factors, (BEF) established by the CEE, (Consortium for Energy Efficiency). For additional information on this program go to: www.cee1.org or www.nema.org
118
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
BEF1 1.61 1.61 1.72 1.89 2.04 1.10 1.10 1.18 1.29 1.40 0.82 0.82 0.88 0.93 1.00
49249
49491
QHE ISM models above also operate FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W), FBO29/SS (29W)
E L E C T R O N I C B A L L A S T S
QHE ISH models above also operate FBO32, FBO31, FBO30/SS (30W) & FBO29/SS (29W) QHE ballasts operate additional T8 lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. Banded Pack, (add -B to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, except Item Number 49878* contains 500 pieces, (add -PAL to Description).
SYLVANIA OCTRON ECOLOgIC3 fluorescent lamps are designed to satisfy the Federal Toxicity Characteristic Leaching Procedure (TCLP) criteria for classification as nonhazardous waste in most states.* ECOLOgIC3 represents a more comprehensive approach to sustainability encompassing high efficiency, long life and RoHS/TCLP compliance. *Regulations may vary. Check your local and state regulations. NEMA Premium Ballast (NPB) program compliant. The NPB program promotes the use of high efficiency T8 electronic ballasts by meeting or exceeding the Ballast Efficiency Factors, (BEF) established by the CEE, (Consortium for Energy Efficiency). For additional information on this program go to: www.cee1.org or www.nema.org
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
119
BEF1 3.08 3.08 3.21 3.52 3.67 1.60 1.60 1.71 1.83 2.03 1.05 1.05 1.13 1.20 1.35 0.80 0.80 0.86 0.91 1.01 3.11 3.11 3.35 3.63 3.95 1.58 1.58 1.67 1.85 2.02 1.07 1.07 1.14 1.23 1.36 0.81 0.81 0.85 0.93 1.01
49200 49396
E L E C T R O N I C B A L L A S T S
49367 49397
49368 49398
49383 49384
49385 49386
49387 49388
QHE ISL, ISN, TypeCC models above also operate FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W), FBO29/SS (29W) QHE ballasts operate additional T8 lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. Banded Pack, (add -B to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add -PAL to Description).
120
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
BEF1 1.62 1.62 1.71 1.84 2.07 1.07 1.07 1.14 1.22 1.36 0.82 0.82 0.86 0.93 1.04
49785
49787
QHE ISH TypeCC models above also operate FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W), FBO29/SS (29W) QHE ballasts operate additional T8 lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. Banded Pack, (add -B to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add -PAL to Description).
E L E C T R O N I C B A L L A S T S
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
121
BEF1 3.00 3.00 3.25 3.39 3.90 1.53 1.53 1.63 1.73 1.95 1.04 1.04 1.10 1.16 1.32 0.80 0.80 0.85 0.91 1.01 2.93 2.93 3.14 3.38 3.83 1.49 1.49 1.60 1.69 1.91 1.02 1.02 1.09 1.16 1.31 0.79 0.79 0.84 0.90 1.00
E L E C T R O N I C B A L L A S T S
Instant Start QTP ISL and ISN also operate these lamps: FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W), FBO29/SS (29W) Ballasts operate additional T8 lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. Banded Pack, (add -B to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add -PAL to Description).
122
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
BEF1 2.93 2.93 3.07 3.33 3.75 1.54 1.54 1.64 1.74 1.97 1.06 1.06 1.13 1.20 1.34
Instant Start QTP ISH also operate these lamps: FBO32, FBO31, FBO30/SS (30W) & FBO29/SS(29W) QTP ballasts operate additional T8 lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. Banded Pack, (add -B to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add -PAL to Description).
E L E C T R O N I C B A L L A S T S
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
123
BEF1 2.84 2.84 2.96 3.23 3.55 1.54 1.54 1.65 1.78 1.97 1.00 1.00 1.06 1.15 1.27 0.78 0.78 0.83 0.89 0.96
E L E C T R O N I C B A L L A S T S
51397 51398
51408 51409
51413 51414
51418 51419
0.26/0.11 0.26/0.11 0.24/0.10 0.22/0.10 0.20/0.09 0.48/0.21 0.48/0.21 0.46/0.20 0.43/0.18 0.38/0.16 0.69/0.29 0.69/0.29 0.68/0.28 0.62/0.27 0.56/0.24 0.93/0.39 0.93/0.39 0.89/0.38 0.83/0.35 0.77/0.33
FO32/700 FO32/XPS FO30/SS FO28/SS FO25/SS FO32/700 FO32/XPS FO30/SS FO28/SS FO25/SS FO32/700 FO32/XPS FO30/SS FO28/SS FO25/SS FO32/700 FO32/XPS FO30/SS FO28/SS FO25/SS
2800 3100 2850 2725 2475 2800 3100 2850 2725 2475 2800 3100 2850 2725 2475 2800 3100 2850 2725 2475
1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4
0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88
2465 2730 2510 2400 2180 4930 5455 5015 4795 4355 7390 8185 7525 7195 6535 9855 10,910 10,030 9590 8710
2220 2565 2360 2255 2045 4435 5130 4715 4510 4095 6655 7695 7075 6760 6140 8870 10,255 9430 9015 8190
30/29 30/29 28/26 26/25 23 57/55 57/55 55/53 51/50 45/44 83/82 83/82 80/78 73/72 67/66 111/108 111/108 105/103 98/95 91/89
3.03 3.03 3.38 3.52 3.83 1.60 1.60 1.66 1.76 2.00 1.07 1.07 1.13 1.22 1.33 0.81 0.81 0.85 0.93 0.99
Ballast models above also operate FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W), FBO29/SS (29W) Ballasts operate additional T8 lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. Banded Pack, (add -B to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add -PAL to Description).
124
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
BEF1
49450 49459
49453 49460
49455 49470
0.60/0.27 0.60/0.27 0.57/0.25 0.53/0.23 0.47/0.20 0.94/0.4 0.94/0.4 0.88/0.37 0.81/0.34 0.72/0.31 1.22/0.53 1.22/0.53 1.13/0.49 1.06/0.46 0.95/0.41
FO32/700 FO32/XPS FO30/SS FO28/SS FO25/SS FO32/700 FO32/XPS FO30/SS FO28/SS FO25/SS FO32/700 FO32/XPS FO30/SS FO28/SS FO25/SS
2800 3100 2850 2725 2475 2800 3100 2850 2725 2475 2800 3100 2850 2725 2475
2 2 2 2 2 3 3 3 3 3 4 4 4 4 4
1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15
6440 7130 6555 6270 5695 9660 10,695 9835 9400 8540 12,880 14,260 13,110 12,535 11,385
5795 6700 6160 5890 5350 8695 10,055 9245 8835 8025 11,590 13,405 12,325 11,785 10,700
72/70 72/70 69/67 63/62 56/55 110/108 110/108 104/101 95/93 85/84 143/141 143/141 99/101 101/102 102/104
1.64 1.64 1.72 1.85 2.09 1.06 1.06 1.14 1.24 1.37 0.82 0.82 0.88 0.93 1.05
Ballast models above also operate FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W), FBO29/SS (29W) Ballasts operate additional T8 lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. Banded Pack, (add -B to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add -PAL to Description).
E L E C T R O N I C B A L L A S T S
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
125
BEF1
50304 50305
F96T8HO (86W) F72T8HO (65W) F60T8HO (55W) F48T8HO (44W) F96T8HO (86W) F72T8HO (65W) F60T8HO (55W) F48T8HO (44W)
2 2 2 2 1 1 1 1
E L E C T R O N I C B A L L A S T S
Ballasts operate additional T8 lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. Banded Pack, (add -B to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add -PAL to Description).
126
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
BEF1 0.82 0.82 0.91 0.96 1.08 1.60 0.82 0.82 0.90 0.96 1.08 1.61
E L E C T R O N I C B A L L A S T S
Ballasts operate additional T8 lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com FO96T8/XP/SS (55W) has been re-rated to FO96/54W/XP/SS. 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value uless otherwise noted. Banded Pack, (add -B to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add -PAL to Description).
BEF1 0.80 0.80 0.86 1.05 1.53 1.52 1.65 2.00 2.86
Ballasts operate additional T8 lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com FO96T8/XP/SS (55W) has been re-rated to FO96/54W/XP/SS. 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. Banded Pack, (add -B to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add -PAL to Description).
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
127
QUICKTRONIC 347 Volt CANADIAN Systems QUICKTRONIC High Efficiency 32 T8 Instant Start 347V Systems CANADA
Item Number 49471 OSRAM SYLVANIA Description QHE 1X32T8/347 ISL-SC Input Current (AMPS) 0.08 0.08 0.07 0.07 0.06 0.14 0.14 0.13 0.12 0.12 0.21 0.21 0.20 0.18 0.17 0.28 0.28 0.26 0.25 0.23 0.08 0.08 0.08 0.07 0.07 0.16 0.16 0.15 0.14 0.13 0.25 0.25 0.24 0.22 0.20 0.33 0.33 0.31 0.29 0.26 Lamp Type FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS FO32/700 FO32/XP FO30/SS FO28/SS FO25/SS Rated Lumens (lm) 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 2800 3000 2850 2725 2475 No. of Lamps 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 Ballast Factor (BF) 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 0.88 System Lumens 2185 2340 2220 2125 1930 4370 4680 4445 4250 3860 6550 7020 6670 6380 5790 8735 9360 8890 8500 7720 2465 2640 2510 2400 2175 4925 5280 5015 4800 4355 7390 7920 7525 7195 6530 9855 10,560 10,030 9590 8710 Mean Lumens 1965 2200 2090 2000 1815 3930 4400 4180 3995 3630 5895 6600 6270 5995 5445 7860 8800 8360 7990 7260 2220 2480 2360 2255 2045 4435 4965 4715 4510 4095 6655 7445 7075 6765 6140 8870 9925 9430 9015 8190 Input Power (W) 25 25 24 22 20 48 48 46 43 38 71 71 67 62 55 96 96 90 84 74 28 28 27 25 22 55 55 52 48 43 83 83 78 74 66 109 109 103 97 87 System Efficacy2 (lm/W) 87 94 93 97 97 91 98 97 99 102 92 99 100 103 105 91 98 99 101 104 88 94 93 96 99 90 96 96 100 101 89 95 96 97 99 90 97 97 99 100 BEF1 3.12 3.12 3.25 3.55 3.90 1.63 1.63 1.70 1.81 2.05 1.10 1.10 1.16 1.26 1.42 0.81 0.81 0.87 0.93 1.05 3.14 3.14 3.26 3.52 4.00 1.60 1.60 1.69 1.83 2.05 1.06 1.06 1.13 1.19 1.33 0.81 0.81 0.85 0.91 1.01
49473
E L E C T R O N I C B A L L A S T S
49475
49477
49463
49465
49467
Instant Start QHE ISL and ISN models also operate FBO32, FBO31, FO25, FBO24, FO17, FBO16, FBO30/SS (30W), FBO29/SS (29W) Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.
128
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
QUICKTRONIC 347 Volt CANADIAN Systems QUICKTRONIC 32 T8 Instant Start 347V Systems CANADA
Item Number 49241 49939 OSRAM SYLVANIA Description QT2x32T8/347 ISL-SC QT4x32T8/347 ISL-SC Input Current (AMPS) 0.15 0.28 Lamp Type FO32/XP FO32/XP Rated Lumens (lm) 3000 3000 No. of Lamps 2 4 Ballast Factor (BF) 0.77 0.77 System Lumens 4620 9240 Mean Lumens 4345 8685 Input Power (W) 51 98 System Efficacy2 (lm/W) 91 94 BEF1 1.51 0.79
QTP ISN models above also operate FBO32, FBO31, FO25, FBO24, FO17, FBO16, F030/SS (30W), FBO30/SS (30W), FBO29/SS (29W), F028/SS (28W), FO25/SS (25W)
QTP ISN models above also operate FBO32, FBO31, FO25, FBO24, FO17, FBO16, F030/SS (30W), FBO30/SS (30W), FBO29/SS (29W), F028/SS (28W), FO25/SS (25W)
E L E C T R O N I C B A L L A S T S
QT2x59/347 IS
0.33
FO96T8 XP(59W)
6100
0.88
10,735
10,090
110
98
0.8
QT IS 2x59 model above also operates the FO96/SS lamp (55W) Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). System Efficacy calculation based on lowest input power value unless otherwise noted. Pallet Pack contains 840 pieces, (add PAL to Description).
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
129
BEF1 1.60 1.04 1.67 1.09 1.83 1.14 2.03 1.19 3.12 1.67 3.25 1.67 3.55 1.79 3.90 1.92 1.61 1.26 1.67 1.31 1.80 1.36 2.05 1.42 3.00 2.00 3.35 2.13 3.52 2.27 3.83 2.43
E L E C T R O N I C B A L L A S T S
49157 49156
T5HO at 35C lamp ambient temperature Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.
130
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
T8 POWERSENSE models above also operate FO25, FO17, FO30/SS, FO28/SS, FO25/SS, FBO32, FBO31, FBO24, FBO16. See full specifications for details and controls
E L E C T R O N I C B A L L A S T S
POWERSENSE ballasts work with Fluorescent Power Line Dimmers and 0-10VDC controls. For a list of available controls, please refer to the ECOLOGIC control section in this catalog or visit http://www.sylvania.com
BEF1 1.61
277
0.23
FP54T5HO 5000
82
1.64
120
1.07
FP54T5HO 5000
83
0.83
277
0.45
FP54T5HO 5000
85
0.85
HELIOS ballasts work with 0-10VDC controls. For a list of available controls, please refer to the ECOLOGIC control section in this catalog or visit http://www.sylvania.com. T5/T5HO at 35C lamp ambient temperature Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
131
E L E C T R O N I C B A L L A S T S
T5/T5HO at 35C lamp ambient temperature Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com DALI ballasts works with DALI controls. Please contact DALI control manufacturers for additional details. Also go to www.lightingcontrolsassociation.org 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. Ballasts will be replaced by QHE High Efficiency DALI models. Contact OSRAM SYLVANIA for product availability and detailed specifications.
DALI Controls Information Siemens Building Technology http://sbt.siemens.com Cooper http://greengate.coopercontrol.com Crestron www.crestron.com Hunt Dimming www.huntdimming.com Leviton www.leviton.com Starfield Controls www.starfieldcorp.com Watt Stopper www.wattstopper.com Please contact controls manufacturer to order/specify controls. For the latest controls list go to www.sylvania.com Also for more information, check out the LCA (Lighting Controls Association) site: www.lightingcontrolsassociation.org
132
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
BEF1 5.00 2.63 3.57 1.85 2.63 1.43 2.00 1.10 2.27 1.06
0.60/0.26 32W DT/E 0.43/0.19 42W DT/E 0.82/0.36 42W DT/E 0.41/0.17 0.83/0.37 40W DL 40W DL
E L E C T R O N I C B A L L A S T S
T5/T5HO at 35C lamp ambient temperature Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com DALI ballasts works with DALI controls. Please contact DALI control manufacturers for additional details. Also go to www.lightingcontrolsassociation.org 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.
DALI Controls Information Siemens Building Technology http://sbt.siemens.com Cooper http://greengate.coopercontrol.com Crestron www.crestron.com Hunt Dimming www.huntdimming.com Leviton www.leviton.com Starfield Controls www.starfieldcorp.com Watt Stopper www.wattstopper.com Please contact controls manufacturer to order/specify controls. For the latest controls list go to www.sylvania.com Also for more information, check out the LCA (Lighting Controls Association) site: www.lightingcontrolsassociation.org
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
133
QHE2x28T5/UNV PSN 0.55/0.23 20-pack (connectors/no leads) 0.68/0.29 10-pack (with leads) 0.39/0.18 0.27/0.13 0.27/0.12 0.34/0.15 0.21/0.10 0.15/0.07
54 T5HO, Type CC, High Ambient Temperature (HT-90C max case temp) Universal Voltage (120-277V)
51476 (51475)* QHE2x54T5HO/UNV PSN-HT 20-pack (connectors/no leads) QHE2x54T5HO/UNV PSN-HT-MCL 10-pack (with leads) 1.00/0.43 0.94/0.40 0.89/0.38 0.88/0.37 0.99/0.42 0.92/0.39 0.82/0.35 0.53/0.23 0.49/0.21 0.45/0.20 0.49/0.21 0.51/0.22 0.48/0.21 0.45/0.20 FP54T5HO FP54/50W/SS FP54/47W/SS FT55DL FT50DL L58 FPC55 FP54T5HO FP54/50W/SS FP54/47W/SS FT55DL FT50DL L58 FPC55 5000 5000 4575 4800 4300 5200 4000 5000 5000 4575 4800 4300 5200 4000 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1.00 1.02 1.02 0.86 1.04 0.85 0.80 1.05 1.05 1.03 0.92 1.09 0.87 0.81 10,000 10,200 9375 8255 8945 8840 6400 5250 5250 4690 4415 4685 4525 3240 9300 9485 8720 7680 8320 8220 5950 4885 4885 4365 4105 4360 4205 3015 119 112 105 106 110 111 96 62 58 53 56 57 57 49 116 109 103 105 108 108 94 61 58 53 55 57 57 49 86 94 91 79 83 82 68 86 91 88 80 82 79 66 0.86 0.94 0.99 0.82 0.96 0.79 0.85 1.72 1.81 1.94 1.67 1.91 1.53 1.65
T5/T5HO at 35C lamp ambient temperature (Item Number)* = Item Number/NAED in parentheses are models with leads/wires. No parenthesis = Ballasts with connectors only/no leads Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.
134
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
BEF1 0.44 0.49 0.50 0.43 0.46 0.40 0.42 0.58 0.62 0.67 0.56 0.62 0.54 0.57 0.86 0.96 1.01 0.87 0.95 0.81 0.85 1.78 1.89 2.00 1.64 1.82 1.58 1.73
(51480)*
QHE4x54T5HO/UNV PSN-HT-SCL 2.00/0.90 10-pack (with leads) 1.77/0.76 1.75/0.75 1.82/0.78 1.90/0.81 1.87/0.89 1.77/0.77 1.50/0.65 1.43/0.62 1.34/0.58 1.39/0.60 1.43/0.62 1.42/0.61 1.38/0.60 1.00/0.45 0.95/0.42 0.88/0.39 0.92/0.41 0.94/0.42 0.93/0.41 0.91/0.41 0.51/0.25 0.49/0.24 0.45/0.23 0.47/0.23 0.48/0.24 0.49/0.24 0.48/0.24
E L E C T R O N I C B A L L A S T S
T5/T5HO at 35C lamp ambient temperature (Item Number)* = Item Number/NAED in parentheses are models with leads/wires. No parenthesis = Ballasts with connectors only/no leads Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
135
QUICKTRONIC T5HO 347-480V Systems QUICKTRONIC High Efficiency T5HO PROStart 347-480V Systems
54 T5HO, Type CC, High Ambient Temperature (HT-90C max case temp) 347-480V
Item Number OSRAM SYLVANIA Description QHE2x54T5HO/347-480 PSN-HT 20-pack (Connectors/no leads) QHE2x54T5HO/347-480 PSN-HT-MCL 10-pack (with leads) Input Current (AMPS) 0.35/0.25 0.30/0.23 0.30/0.22 0.32/0.23 0.33/0.24 0.31/0.22 0.26/0.22 0.18/0.14 0.16/0.11 0.15/0.11 0.17/0.13 0.18/0.14 0.17/0.12 0.14/0.11 Lamp Type FP54T5HO FP54/50W/SS FP54/47W/SS FT55DL FT50DL L58 FPC55 FP54T5HO FP54/50W/SS FP54/47W/SS FT55DL FT50DL L58 FPC55 FP54T5HO FP54/50W/SS FP54/47W/SS FT55DL FT50DL L58 FPC55 FP54T5HO FP54/50W/SS FP54/47W/SS FT55DL FT50DL L58 FPC55 FP54T5HO FP54/50W/SS FP54/47W/SS FT55DL FT50DL L58 FPC55 FP54T5HO FP54/50W/SS FP54/47W/SS FT55DL FT50DL L58 FPC55 Rated Lumens (lm) 5000 5000 4575 4800 4300 5200 4000 5000 5000 4575 4800 4300 5200 4000 5000 5000 4575 4800 4300 5200 4000 5000 5000 4575 4800 4300 5200 4000 5000 5000 4575 4800 4300 5200 4000 5000 5000 4575 4800 4300 5200 4000 No. of Lamps 2 2 2 2 2 2 2 1 1 1 1 1 1 1 4 4 4 4 4 4 4 3 3 3 3 3 3 3 2 2 2 2 2 2 2 1 1 1 1 1 1 1 Ballast Factor (BF) 1.00 1.00 1.02 0.86 1.00 1.00 0.75 1.00 1.01 0.98 0.87 1.02 0.87 0.77 1.00 1.02 1.02 0.91 1.02 0.97 0.88 1.03 1.02 1.04 0.92 1.03 0.97 0.92 1.03 1.02 1.03 0.93 1.04 0.97 0.90 1.05 1.03 1.04 0.90 1.04 0.98 0.95 Input System System Mean Power (W) Efficacy2 Lumens Lumens 347V 480V (lm/W) 10,000 10,000 9335 8255 8600 10,400 6000 5000 5050 4484 4175 4385 4525 3080 20,000 20,400 18,665 17,470 17,545 20,175 14,080 15,450 15,300 14,275 13,250 13,285 15,130 11,040 10,300 10,200 9425 8930 8945 10,090 7200 5250 5150 4760 4320 4470 5095 3800 9300 9300 8680 7680 8000 9670 5580 4650 4695 4170 3885 4080 4205 2864 18,600 18,970 17,360 16,250 16,315 18,765 13,095 14,370 14,230 13,275 12,320 12,355 14,075 10,265 9580 9485 8765 8305 8320 9385 6695 4885 4790 4425 4020 4160 4740 3535 118 109 104 104 109 108 91 60 56 52 55 57 56 48 232 212 205 217 225 214 181 178 165 156 165 170 162 144 118 108 103 107 112 106 91 59 56 53 56 57 58 55 117 108 102 103 108 107 90 59 55 51 54 56 55 47 228 207 203 215 222 213 175 177 164 155 163 167 162 141 116 106 101 106 109 106 89 58 55 53 55 57 57 53 85 93 92 80 80 97 67 85 92 88 77 78 82 66 88 99 92 81 79 95 80 87 93 92 81 80 93 78 89 96 93 84 82 95 81 91 94 90 79 78 89 72
BEF1 0.85 0.93 1.00 0.83 0.93 0.93 0.83 1.69 1.84 1.92 1.61 1.82 1.58 1.64 0.44 0.49 0.50 0.42 0.46 0.46 0.50 0.58 0.62 0.67 0.56 0.62 0.60 0.65 0.89 0.96 1.02 0.88 0.95 0.92 1.01 1.81 1.87 1.96 1.64 1.82 1.72 1.79
51486 51485
E L E C T R O N I C B A L L A S T S
51481
QHE4x54T5HO/347-480 PSN-HT-SCL 0.67/0.48 10-pack (with leads) 0.63/0.45 0.59/0.43 0.63/0.46 0.66/0.48 0.62/0.45 0.51/0.37 0.51/0.37 0.48/0.35 0.45/0.33 0.48/0.35 0.49/0.36 0.47/0.34 0.41/0.30 0.33/0.24 0.32/0.24 0.30/0.23 0.31/0.24 0.33/0.24 0.31/0.23 0.27/0.20 0.17/0.13 0.17/0.13 0.16/0.13 0.17/0.13 0.17/0.14 0.17/0.13 0.14/0.12
T5/T5HO at 35C lamp ambient temperature (Item Number)* = Item Number/NAED in parentheses are models with leads/wires. No parenthesis = Ballasts with connectors only/no leads Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.
136
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
QUICKTRONIC T5HO 347-480V Systems QUICKTRONIC Professional Series T5HO PROStart 347-480V Systems
54 T5HO, High Ambient Temperature (HT-90C max case temp) 347-480V
Item Number 49146 (49145)* OSRAM SYLVANIA Description Input Current (AMPS) Lamp Type FP54T5HO FP54T5HO Rated Lumens (lm) 5000 5000 No. of Lamps 2 1 Ballast Factor (BF) 1.00 1.00 Input System System Mean Power (W) Efficacy2 Lumens Lumens 347V 480V (lm/W) 10,000 5000 9300 4650 121 61 120 61 83 82
QUICKTRONIC T5 347V Systems CANADA QUICKTRONIC Professional Series T5 PROStart 347V Systems CANADA
28 T5, 347V
Item Number OSRAM SYLVANIA Description QTP2x28T5/347 PS-SC (10 pack with leads) Input Current (AMPS) 0.18 0.14 0.10 Lamp Type FP28T5 FP21T5 FP14T5 Rated Lumens No. of (lm) Lamps
QTP 2x54T5HO Fixed Output
BEF
49185
2 2 2
T5/T5HO at 35C lamp ambient temperature (Item Number)* = Item Number/NAED in parentheses are models with leads/wires. No parenthesis = Ballasts with connectors only/no leads Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.
E L E C T R O N I C B A L L A S T S
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
137
PROStart QTP 28WT5 PSN models above also operate these lamps: FP14T5, FP21T5 & FP35T5
BEF1 3.45 2.38 1.85 3.45 1.20 2.38 1.67 0.85 1.64 1.11 1.11
E L E C T R O N I C B A L L A S T S
54 T5HO, High Ambient Temperature (HT-90C max case temp) Universal Voltage (120-277V)
QTP 2x54 T5HO Fixed Output
49136 (49135)*
QTP2x54T5HO/UNV PSN-HT
1.00/0.43 0.96/0.41 0.89/0.38 0.53/0.24 0.50/0.21 0.45/0.21 2.05/0.90 1.85/0.80 1.72/0.75 1.51/0.65 1.46/0.62 1.34/0.58 1.00/0.45 0.95/0.42 0.88/0.39 0.51/0.25 0.50/0.25 0.47/0.25
FP54T5HO FP54/50W/SS FP54/47W/SS FP54T5HO FP54/50W/SS FP54/47W/SS FP54T5HO FP54/50W/SS FP54/47W/SS FP54T5HO FP54/50W/SS FP54/47W/SS FP54T5HO FP54/50W/SS FP54/47W/SS FP54T5HO FP54/50W/SS FP54/47W/SS
5000 5000 4575 5000 5000 4575 5000 5000 4575 5000 5000 4575 5000 5000 4575 5000 5000 4575
2 2 2 1 1 1 4 4 4 3 3 3 2 2 2 1 1 1
1.00 1.02 1.02 1.05 1.05 1.03 1.00 1.02 1.02 1.00 1.04 1.04 1.00 1.03 1.03 1.00 1.06 1.06
10,000 10,200 9335 5250 5250 4710 20,000 20,400 18,665 15,000 15,600 14,275 10,000 10,300 9425 5000 5300 4850
9300 9485 8680 4885 4885 4380 18,600 18,970 17,360 13,950 14,510 13,275 9300 9580 8765 4650 4930 4510
121/118 115/112 106/103 62/61 59/58 54/53 241/236 221/215 205/200 183/181 175/170 161/158 121/118 114/111 105/104 61/61 60/58 55/54
85 91 91 86 91 89 85 95 93 83 92 90 85 93 91 82 91 90
0.85 0.91 0.99 1.72 1.81 1.94 0.42 0.47 0.51 0.55 0.61 0.66 0.85 0.93 0.99 1.64 1.83 1.96
49161
PROStart QTP 54 T5HO PSN models above also operate these lamps: FT55DL, FPC55, L58 T5/T5HO at 35C lamp ambient temperature (Item Number)* = Item Number/NAED in parentheses are models with leads/wires. No parenthesis = Ballasts with connectors only/no leads Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.
138
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
54 T5HO Low Ballast Factor (0.80) and QUICKSTEP (Bi-Level) T5HO Universal Voltage (120-277V)
Item Number (49418)* (49419)* OSRAM SYLVANIA Description QTP 2x54T5HO/UNV PS80SC QS 2x54T5HO/UNV PS80SC (@100%) (@50%) Input Current (AMPS) Lamp Type Rated Lumens (lm) 5000 5000 5000 No. of Lamps 2 2 2 Ballast Factor (BF) 0.80 0.80 0.40 System Lumens 8000 8000 4000 Mean Lumens 7440 7440 3720 Input Power (W) 96/93 96/93 52/51 System Efficacy2 (lm/W) 83/86 83/86 77/78
T5/T5HO at 35C lamp ambient temperature (Item Number)* = Item Number/NAED in parentheses are models with leads/wires. No parenthesis = Ballasts with connectors only/no leads Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.
E L E C T R O N I C B A L L A S T S
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
139
NOTES:
E L E C T R O N I C B A L L A S T S
140
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
QUICKTRONIC High Efficiency DL40 & SUPERSAVER DULUX Instant Start Systems
FT40DL (TT5) and FT40DL/SS Instant Start Universal Voltage (120-277V)
Item Number 49428 OSRAM SYLVANIA Description QHE1x40DL/UNV ISN-SC Input Current (AMPS) 0.30/0.13 0.27/0.12 0.22/0.10 0.56/0.26 0.54/0.24 0.43/0.19 0.84/0.36 0.79/0.35 0.62/0.27 Lamp Type FT40T5 FT40DL/28W/SS FT40DL/25W/SS FT40T5 FT40DL/28W/SS FT40DL/25W/SS FT40T5 FT40DL/28W/SS FT40DL/25W/SS Rated Lumens (lm) 3150 2800 2500 3150 2800 2500 3150 2800 2500 No. of Lamps 1 1 1 2 2 2 3 3 3 Ballast Factor (BF) 0.90 1.07 0.96 0.90 1.07 0.95 0.90 1.07 0.95 Input System System Mean Power Efficacy2 Lumens Lumens 120V 277V (lm/W) 2835 2995 2400 5670 5990 4750 8505 8990 7125 2440 2695 2160 4875 5395 4275 7315 8090 6415 35 32 27 68 64 51 100 95 74 35 32 26 67 63 51 99 94 73 81 94 92 85 95 93 86 96 98
BEF1 2.57 3.34 3.69 1.34 1.70 1.86 0.91 1.14 1.30
49429
QHE2x40DL/UNV ISN-SC
49430
QHE3x40DL/UNV ISN-SC
Ballast factor based upon 225mA nominal lamp current for FT40DL and FT40DL/25W/SS and 190mA nominal lamp current for FT40DL/28W/SS (i.e. BF higher).
E L E C T R O N I C B A L L A S T S
BEF1 6.25 3.45 5.00 2.63 3.57 1.85 2.80 2.13 1.89 1.39 1.01 1.61 1.30
0.32/0.14 0.50/0.22
51843 51863
Also compatible with other manufacturers equivalent 4 pin lamp types that meet ANSI specifications. Rated lamp lumens and performance data based on DULUX T/E series 4 pin lamps. T5/T5HO at 35C lamp ambient temperature Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
141
QUICKTRONIC METAL HALIDE and High Pressure Sodium Electronic Systems QUICKTRONIC MH SUPER MINI SYSTEMS
Electronic Metal Halide Systems, Universal Voltage (120-277V)
Item Number 51991 51986 51987 51988 51989 51990 OSRAM SYLVANIA Description QTP1x15MH SM UNV J QTP1x15MH SM UNV F QTP1x20MH SM UNV J QTP1x20MH SM UNV F QTP1x39MH SM UNV J QTP1x39MH SM UNV F Input Voltage (VAC) Input Current (AMPS) Lamp Type1 15W T4 20W T4 Rated Ballast Input System Lumens No. of Internal Factor System Power (W) Efficacy (lm) Lamps IDTP2 (BF) Lumens 120V 277V (lm/W) 1200 1700 3400 1 1 1 Yes Yes Yes 1.00 1.00 1.00 1200 1700 3400 17.5 17.5 23 44 23 44 69 74 77 Lamp ANSI Code3 C186 C156 C130
120-277 0.38/0.16 20W T4.5 120-277 0.39/0.17 120-277 0.75/0.33 120-277 0.67/0.29 39W T6 39W T6 70W T6
110 110
Lamp Type1
Rated Ballast Input System Lumens No. of Internal Factor System Power (W) Efficacy (lm) Lamps IDTP2 (BF) Lumens 120V 277V (lm/W) 1700 1700 3400 3400 7000 7000 7000 9700 1 1 1 1 1 1 1 1 Yes Yes Yes Yes Yes Yes Yes Yes 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1700 1700 3400 3400 7000 7000 7000 9700 23 23 44 44 79 79 76 23 23 44 44 79 79 74 74 74 77 77 89 89 92/95 99/91
Lamp ANSI Code3 C156 C156 C130 C130 C98, C139 C98, C139 C98, C139 C90, C140, C191
QTP1x20MH UNV SQ F
120-277 0.19/0.09 20W T4.5 120-277 0.19/0.09 20W T4.5 120-277 0.38/0.17 39W T6 120-277 0.38/0.17 120-277 0.66/0.29 39W T6 70W T6
QTP1X70MH UNV SQ J 120-277 0.65/0.27 70W T6 QTP1X70MH UNV SLIM F 120-277 0.63 / 0.27 70W T6 QTP1X70MH UNV SLIM J QTP1X100MH UNV SLIM F 120-277 0.91 / 0.39 100W E17 QTP1X100MH UNV SLIM J
109 107
New Product. Contact OSRAM SYLVANIA for product availability. For other compatible lamp types/systems info please refer to the Product information Bulletins and/or Ballast Tech. Applications & Specification Guide and www.sylvania.com. 2 Internal IDTP Insulation Detection Thermal Protector. 3 or quartz equivalent M 4 Ballast can operate 1 or 2 lamps, cap off unused leads individually for 1 lamp operation.
142
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
QUICKTRONIC METAL HALIDE Electronic Systems QUICKTRONIC High Efficiency Metal Halide Systems
High Efficiency Electronic Metal Halide Systems (208-277V)
Item Number 51980 51981 51982 51983 51984
1 2
OSRAM SYLVANIA Description QHE1x200MH 208-277V QHE1x250MH 208-277V QHE1x320MH 208-277V QHE1x350MH 208-277V QHE1x400MH 208-277V
Lamp Type1 200W E39 250W EX39 320W EX39 350W EX39 400W E39
Rated Ballast Input System Lumens No. of Internal Factor System Power (W) Efficacy (lm) Lamps IDTP2 (BF) Lumens 208V 277V (lm/W) 21,000 24,000 37,500 33,000 42,000 1 1 1 1 1 Yes Yes Yes Yes Yes 1.00 1.00 1.00 1.00 1.00 21,000 24,000 37,500 33,000 42,000 215 267 343 374 428 214 266 341 372 426 98 90 109/110 88/89 98/99
Lamp ANSI Code3 C190 C138, C153 C132, C154 C131 C135, C155
New Product/Preliminary Data. Contact OSRAM SYLVANIA for product availability and detailed specifications. For other compatible lamp types/systems info please refer to the Product Information Bulletins and/or Ballast Tech. Applications & Specification Guide and www.sylvania.com. Internal IDTP Insulation Detection Thermal Protector. 3 or quartz equivalent M 4 Ballast can operate 1 or 2 lamps, cap off unused leads individually for 1 lamp operation.
QUICKTRONIC METAL HALIDE Dimming Electronic Systems QUICKTRONIC High Efficiency Metal Halide Dimming Systems
High Efficiency Electronic Metal Halide Systems (208-277V)
Item Number 51992 51993 51994 51995 51996
1
E L E C T R O N I C
Lamp ANSI Code3 C190 C153 C154 C131 C155
OSRAM SYLVANIA Description QHE1x200MH 208-277 DIM QHE1x250MH 208-277 DIM QHE1x320MH 208-277 DIM QHE1x350MH 208-277 DIM QHE1x400MH 208-277 DIM
Lamp Type1 200W E39 250W EX39 320W EX39 350W EX39 400W E39
Rated Ballast Input System Lumens No. of Internal Factor System Power (W) Efficacy (lm) Lamps IDTP2 (BF) Lumens 208V 277V (lm/W) 21,000 24,000 37,500 33,000 42,000 1 1 1 1 1 Yes Yes Yes Yes Yes 1.00 1.00 1.00 1.00 1.00 21,000 24,000 37,500 33,000 42,000 215 267 343 374 428 214 266 341 372 426 98 90 109/110 88/89 98/99
B A L L A S T S
New Product/Preliminary Data. Contact OSRAM SYLVANIA for product availability and detailed specifications. For other compatible lamp types/systems info please refer to the Product information Bulletins and/or Ballast Tech. Applications & Specification Guide and www.sylvania.com. 2 Internal IDTP Insulation Detection Thermal Protector. 3 or quartz equivalent M 4 Ballast can operate 1 or 2 lamps, cap off unused leads individually for 1 lamp operation.
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
143
} }
Item Number 26087 26088 26089
Rated lamp lumens and performance data based on SYLVANIA ICETRON lamps. Use only with SYLVANIA ICETRON lamps (for additional lamp types contact OSRAM SYLVANIA).
E L E C T R O N I C B A L L A S T S
Ballasts operate additional lamp types. Complete performance data is in the Ballast Technology Applications & Specification Guide and at www.sylvania.com 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted.
144
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
BEF1 1.19
1.12/0.50 F96T12/D41/ECO 6420 0.91/0.40 F96T12/CW/SS 5300 0.88/0.40 F72T12/CW 4500 0.62/0.28 F48T12/CW 2820 0.52/0.24 F48T12/CW/SS 2450 0.69/0.31 F96T12/D41/ECO 6420 0.56/0.27 F96T12/CW/SS 5300 0.55/0.26 F72T12/CW 4500
E L E C T R O N I C B A L L A S T S
1.65/0.71 F96T12HO 1.38/0.60 F96T12HO/SS 1.30/0.56 F72T12HO 1.10/0.47 F60T12HO 0.88/0.38 F48T12HO 0.88/0.38 F96T12HO
96T12HO rated lamp lumens and performance data based on F96T12CW/HO/SS and F96T12/D41/HO series lamps. New 50319 QTP2x96T12HO/UNV model replaces 49883 QT2x96/120HO and 49984 QT2x96/277 HO that are discontinued. Also compatible with other manufacturers equivalent lamp types that meet ANSI standards. 1 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value). 2 System Efficacy calculation based on lowest input power value unless otherwise noted. New Product/Preliminary Data. Contact OSRAM SYLVANIA for product availability and detailed specifications.
Magnetic Discontinued Products 48011 48120 48001 48121 48018 48124 48125 48126 48025 48027 48127 48128 MB1x40/120RS-SRNK MB1x40/277RS-SRNK MB2x40/120RS-SRNK MB2x40/277RS-SRNK MB2x96/120IS-SRNK MB1x96/120IS-SRNK MB1x96/277IS-SRNK MB2x96/277IS-SRNK MB2x96/HO/120RS-SRNK MB2x96/HO/277RS-SRNK MB1x96/HO/120RS-SRNK MB1x96/HO/277RS-SRNK
Nearest Electronic Ballast Replacement T8 Upsell 49905 ballast & lamp 21763 T8 Upsell 49905 ballast & lamp 21763 50314 50314 50308 50308 50308 50308 50319 50319 50319 50319 QTP1x32T8/UNV ISN-SC & FO32/835/XP/ECO QTP1x32T8/UNV ISN-SC & FO32/835/XP/ECO QTP2x40T12/UNV RS 4 Pack QTP2x40T12/UNV RS 4 Pack QTP2x96T12/UNV IS 3 Pack QTP2x96T12/UNV IS 3 Pack QTP2x96T12/UNV IS 3 Pack QTP2x96T12/UNV IS 3 Pack QTP2x96T12HO/UNV RS 6 Pack QTP2x96T12HO/UNV RS 6 Pack QTP2x96T12HO/UNV RS 6 Pack QTP2x96T12HO/UNV RS 6 Pack
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
145
QUICKCROSS
The smart electronics in SYLVANIA QUICKTRONIC ballasts allow them to outperform the competition. U.L.T. Universal Lighting Technologies (formerly Magnetek)
Item Number
OSRAM SYLVANIA
Advance
gE
Howard
Normal Ballast Factor* 49905 QTP 1x32T8/UNV ISN-SC QTP 2x32T8/UNV ISN-SC QTP 3x32T8/UNV ISN-SC QTP 4x32T8/UNV ISN-SC QTP 1x32T8/UNV ISH-SC QTP 2x32T8/UNV ISH-SC QTP 3x32T8/UNV ISH-SC B132IUNVHP-B B232IUNVHP-B B332IUNVHP-A B432IUNVHP-A N/A N/A N/A GE-132-MV-N GE-232-MV-N GE-332-MV-N GE-432-MV-N N/A GE-232-MV-H GE-332-MV-H N/A EP2/32IS/MV/MC N/A N/A N/A N/A N/A
E L E C T R O N I C B A L L A S T S
146
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
QUICKCROSS
The smart electronics in SYLVANIA QUICKTRONIC ballasts allow them to outperform the competition. U.L.T. Universal Lighting Technologies (formerly Magnetek)
Item Number
OSRAM SYLVANIA
Advance
gE
Howard
Normal Ballast Factor* 49968 49969 49970 49971 49248 49249 49491 49919 49920 49921 49922 QHE1X32T8/UNV ISN-SC QHE2X32T8/UNV ISN-SC QHE3X32T8/UNV ISN-SC QHE4X32T8/UNV ISN-SC QHE2x32T8/UNV ISM-SC QHE3x32T8/UNV ISM-SC QHE4x32T8/UNV ISM-SC QHE1X32T8/UNV ISH-SC QHE2X32T8/UNV ISH-SC QHE3X32T8/UNV ISH-SC QHE4X32T8/UNV ISH IOPA-1P32-SC IOPA-2P32-SC IOPA-3P32-SC IOPA-4P32-SC N/A N/A N/A IOPA-1P32-HL-SC IOPA-2P32-HL-SC IOPA-3P32-HL-SC IOPA-4P32-HL B132IUNVHE-A B232IUNVHE-A B332IUNVHE-A B432IUNVHE-A N/A N/A N/A N/A B232IUNVHEH-A B332IUNVHEH-A N/A GE-132-MAX-N/ULTRA GE-232-MAX-N/ULTRA GE-332-MAX-N/ULTRA GE-432-MAX-N/ULTRA GE232MAX-N+ GE332MAX-N+ GE432MAX-N+ N/A GE-232-MAX-H/ULTRA GE-332-MAX-H/ULTRA GE-432-MAX-H/ULTRA
E L E C T R O N I C B A L L A S T S
QUICKTRONIC HIGH EFFICIENCY 32 T8 INSTANT START UNIVERSAL VOLTAGE SYSTEMS - TYPE CC & LAMP STRIATION CONTROL TYPE CC & LAMP STRIATION CONTROL
Low Ballast Factor* 49199 49200 49367 49368 49381 49383 49385 49387 49783 49785 49787 QHE1X32T8/UNV ISL-SC-1 QHE2X32T8/UNV ISL-SC-1 QHE3X32T8/UNV ISL-SC-1 QHE4X32T8/UNV ISL-SC-1 QHE1X32T8/UNV ISN-SC-1 QHE2X32T8/UNV ISN-SC-1 QHE3X32T8/UNV ISN-SC-1 QHE4X32T8/UNV ISN-SC-1 QHE2x32T8/UNV ISH-HT-SC-1 QHE3x32T8/UNV ISH-HT-SC-1 QHE4x32T8/UNV ISH-HT-1 IOP-1P32-LW-SC IOP-2P32-LW-SC IOP-3P32-LW-SC IOP-4P32-LW-SC IOP-1P32-SC IOP-2P32-SC IOP-3P32-SC IOP-4P32-SC IOP-2P32-HL-SC IOP-3P32-HL-90C-SC IOP-4P32-HL-90C-G N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A GE-132-MAX-L/ULTRA GE-232-MAX-L/ULTRA GE-332-MAX-L/ULTRA GE-432-MAX-L/ULTRA GE-132-MAX-N/ULTRA GE-232-MAX-N/ULTRA GE-332-MAX-N/ULTRA GE-432-MAX-N/ULTRA GE-232-MAX-H/Ultra GE-332-MAX-H/Ultra GE-432-MAX-H/Ultra N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
147
QUICKCROSS
The smart electronics in SYLVANIA QUICKTRONIC ballasts allow them to outperform the competition. U.L.T. Universal Lighting Technologies (formerly Magnetek)
Item Number
Advance
gE
Howard
E L E C T R O N I C B A L L A S T S
QT2x59/347IS
N/A
N/A
GE259-N-347
N/A
QUICKTRONIC RESIDENTIAL 32 T8 INSTANT START 120 VOLT SYSTEMS (For Residential Use Only)
Residential Series, Normal Ballast Factor* 49313 49317 QTR 2x32T8/120 ISN-SC QTR 4x32T8/120 ISN-SC N/A N/A B232I120RES-A B232I120RES-G B432I120RES-A GE232-120-RES GE432-120-RES N/A N/A
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
148
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
QUICKCROSS
The smart electronics in SYLVANIA QUICKTRONIC ballasts allow them to outperform the competition. U.L.T. Universal Lighting Technologies (formerly Magnetek)
Item Number
OSRAM SYLVANIA
Advance
gE
Howard
High Efficiency, Normal Ballast Factor, Type CC, Lamp Striation Control, Parallel Operation*
High Efficiency, High Ballast Factor, Type CC, Lamps Striation Control, 90C Case Temperature Parallel Operation*
E L E C T R O N I C B A L L A S T S
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
149
Notes
E L E C T R O N I C B A L L A S T S
150
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
QUICKCROSS
The smart electronics in SYLVANIA QUICKTRONIC ballasts allow them to outperform the competition. U.L.T. Universal Lighting Technologies (formerly Magnetek)
Item Number
Advance
gE
Howard
High Efficiency, Normal Ballast Factor, High Temperature* 51476 QHE 2X54T5HO/UNV PSN-HT GE254MVPS90-F GE454MVPS90-G GE454MVPS90-E N/A
51480
N/A
E L E C T R O N I C B A L L A S T S
High Efficiency, Normal Ballast Factor, High Temperature, 347-480V* 51486 51481 49111 49111 49131 49150 49136 49161 QHE 2x54T5HO/347-480 PSN-HT QHE4X54T5HO/347-480 PSN-HT-SCL QTP2x39-24T5HO/UNVPSN (FP39T5HO) QTP2x39-24T5HO/UNVPSN (FP24T5HO) QTP2x54T5HO/UNVPSN QTP1x80T5HO/UNVPSN QTP 2x54T5HO/UNV PSN HT QTP 4x54T5HO/UNV PSN HTW N/A N/A ICN-2S39 ICN-2S24 ICN-2S54 ICN-1S80 ICN-2S54-90C ICN-4S54-90C-2LS N/A N/A B239PUNV-DOG1C N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A EP2/54HO/PRS/MV/90CW N/A
Professional Series, Normal Ballast Factor, High Temperature, 347-480V* 49146 QTP 2x54T5HO/347-480 PSN HT HCN-2S54-90C-WL N/A N/A
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
151
QUICKCROSS
The smart electronics in SYLVANIA QUICKTRONIC ballasts allow them to outperform the competition. U.L.T. Universal Lighting Technologies (formerly Magnetek)
Item Number
OSRAM SYLVANIA
Advance
gE
Howard
ICN-2P60-SC
B260IUNVHP
GE-260IS-MV-N
N/A
152
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
QUICKCROSS
The smart electronics in SYLVANIA QUICKTRONIC ballasts allow them to outperform the competition. U.L.T. Universal Lighting Technologies (formerly Magnetek)
Item Number
OSRAM SYLVANIA
Advance
gE
Howard
QUICKTRONIC HIGH EFFICIENCY INSTANT START DL40 (40W TT5) UNIVERSAL VOLTAGE SYSTEMS
High Efficiency, Normal Ballast Factor* 49428 49429 49430 QHE 1x40DL/UNV ISN-SC QHE 2x40DL/UNV ISN-SC QHE 3x40DL/UNV ISN-SC ICN-1TTP40-SC (Non-high-efficiency) ICN-2TTP40-SC (Non-high-efficiency) ICN-3TTP40-SC (Non-high-efficiency) N/A N/A N/A GEC140MAX-A GEC240MAX-A GEC340MAX-A N/A EP2/40IS-TT/MV/SC EP3/40IS-TT/MV/SC
QUICKTRONIC PROFESSIONAL PROStart (Programmed Rapid Start) DL40 (40W TT5) SYSTEMS
Professional Series, Normal Ballast Factor* 50320 50330 50340 50350 50360 50370 QTP1x40TT5/120PSN-F QTP1x40TT5/277PSN-F QTP2x40TT5/120PSN-F QTP2x40TT5/277PSN-F QTP3x40TT5/120PSN-B QTP3x40TT5/277PSN-B REL-1TTS40 VEL-1TTS40 REL-2TTS40 VEL-2TTS40 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A GEC240MVPS-A GEC240MVPS-A N/A N/A N/A N/A N/A N/A N/A N/A
E L E C T R O N I C B A L L A S T S
Item Number
OSRAM SYLVANIA
Advance
U.L.T.
gE
Robertson
QUICKTRONIC PROFESSIONAL PROStart (Programmed Rapid Start) CFL T4 UNIVERSAL VOLTAGE DUAL ENTRY SYSTEMS
Professional Series, Normal Ballast Factor* CFL products run multiple lamp combinations and have various mounting/case styles please refer to actual product specifications 51818 51823 51833 51898 51843 51863 QTP 1/2x13CF/UNV DM QTP 1/2x18CF/UNV DM QTP 2x26CF/UNV DM QTP 2x26CF/UNV DM PEM QTP 2x26/32/42CF/UNV DM QTP 2x26/32/42CF/UNV DM PEM ICF-2S13-H1-LD ICF-2S18-H1-LD ICF-2S26-H1-LD ICF-2S26-M1-BS ICF-2S26-M1-BS-QS ICF- 2S42-M2-LD ICF-2S42-M2-BS C213UNV-BE C213UNV-SE C218UNV-BE C218UNV-SE C2642UNV-BE C2642UNV-SE C2642UNV-BES C242UNV-BE C242UNV-SE C242UNV-BES GEC213-MVPS-SE GEC218-MVPS-SE GEC226-MVPS-SE GEC226-MVPS-3W GEC242-MVPS-SE GEC242-MVPS-3W PSM213CQMVDW PSM218CQMVDW PSM226CQMVDW PSM226CQMVDSW PSP242TRMVDW PSP242TRMVDSW
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
153
QUICKCROSS
The smart electronics in SYLVANIA QUICKTRONIC ballasts allow them to outperform the competition. U.L.T. Universal Lighting Technologies (formerly Magnetek)
Item Number
OSRAM SYLVANIA
Advance
Lutron
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
E L E C T R O N I C B A L L A S T S
154
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
QUICKCROSS
The smart electronics in SYLVANIA QUICKTRONIC ballasts allow them to outperform the competition. U.L.T. Universal Lighting Technologies (formerly Magnetek)
Item Number
OSRAM SYLVANIA
Advance
Lutron
gE (Dedicated Voltage)
Advance
Mark 10 (2 wire) Powerline (Dedicated Voltage) Mark 7 (0-10V) (120-277V)
Lutron
Tu-wire (Powerline) Models Only Eco-10 TVE
gE
UltraStart (0-10V)
Dedicated Voltage
IZT- 132-SC 50705 QTP 1x32T8/UNV DIM-TC REZ-132-SC (120V) VEZ-132-SC (277V)
GE132MVPS-N-V03
E L E C T R O N I C B A L L A S T S
50707
B132R277V5 B232PUNVSV3-A ES5822B IZT-2S32-SC ES5836K ES5834B QTP 2x32T8/UNV DIM-TC ES5817K REZ-2S32-SC (120V) B232SR120V5 2W-T832-120-2 VEZ-2S32-SC (277V) B232SR277V5 IZT-3S32-SC N/A B332SR120V5 B332SR277V5 IZT-4S32 B432P277V5H-E B432P277V5-E ES5851K ES5861K ES5847K N/A N/A N/A
GE232MVPS-N-V03
50714
50716
QTP 3x32T8/UNV DIM-TCL REZ-3S32-SC (120V) VEZ-3S32-SC (277V) N/A QTP 4x32T8/UNV DIM-TCL
High Efficiency, 28W T5 (POWERSENSE is Dual Control, competitors are 0-10VDC or Fluorescent Phase Cut)* 50726 QTP 2x28T5/UNV DIM-TCL N/A N/A N/A N/A N/A N/A
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
155
QUICKCROSS
The smart electronics in SYLVANIA QUICKTRONIC ballasts allow them to outperform the competition. Item Number
OSRAM SYLVANIA
Mount
Advance
Metrolight
Aromat/ULT/VS
Hatch
F J F J F J
N/A RMH-39-K-LF
4.4 x 1.1 x 1.2 4.1 x 1.1 x 1.2
M2012CK-7EUN-J M3912CK-7EUN-F
4.12 x 1.32 x 1.22 3.81 x 1.32 x 1.5
E L E C T R O N I C B A L L A S T S
51991
RMH-39-K-BLS
M3912CK-7EUN-J
QUICKTRONIC PROFESSIONAL MH
METALARC Metal Halide Universal Voltage Operates Ceramic and Most Quartz MH Lamp* 51968 51969 51910 51911 51970 51971 51912 51913 51914 51915 QTP2X20MH/UNV
5.0 x 3.4 x 1.4 4.6 x 3.4 x 1.4 5.0 x 3.4 x 1.4 4.6 x 3.4 x 1.4 5.0 x 3.4 x 1.4 4.6 x 3.4 x 1.4 5.0 x 3.4 x 1.4 4.6 x 3.4 x 1.4 5.0 x 3.4 x 1.4 4.6 x 3.4 x 1.4
F J F J F J F J F J
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
MC20-2-F-UNNU
5.52 x 3.62 x 1.35 4.8 x 3.62 x 1.61
MC100-1-J-UNIU
J J J
MH-39-A-BLS-ID
4.72 x 3.62 x 1.50 4.72 x 3.62 x 1.50 4.72 x 3.62 x 1.50
M3912-27CK-5EUJT2
5.02 x 3.62 x 1.57 5.02 x 3.62 x 1.57 5.02 x 3.62 x 1.57
51913 51915
QTP1X70MH/UNV QTP1X100MH/UNV
IMH-70-A-BLS-ID IMH-100-A-BLS-ID
M7012-27CK-5EUJT2 M10012-27CK-5EUJT2
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
156
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
QUICKCROSS
The smart electronics in SYLVANIA QUICKTRONIC ballasts allow them to outperform the competition. Item Number
OSRAM SYLVANIA
Mount
Advance
Metrolight
Aromat/ULT/VS
Hatch
F J F J F J F J F J
IMH-G20-G-LF
3.8 x 3.0 x 1.2 3.5 x 3.0 x 1.2 3.8 x 3.0 x 1.2 3.5 x 3.0 x 1.2 3.8 x 3.0 x 1.2 3.5 x 3.0 x 1.2
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
M2012CK-6EU-F
3.75 x 3.0 x 1.2 3.3 x 3.0 x 1.56 3.75 x 3.0 x 1.2 3.3 x 3.0 x 1.56 3.75 x 3.1 x 1.3 3.3 x 3.0 x 1.56
MC20-1-F-UNNU
4.04 x 3.0 x 1.21
QT1x20MH SQ
3.5 x 3.0 x 1.54 3.5 x 3.0 x 1.2
MC20-1-J-UNNU
3.45 x 3.13 x 1.27 4.04 x 3.0 x 1.21
QT1x39MH SQ QT1x39MH SQ
3.5 x 3.0 x 1.54 3.5 x 3.0 x 1.2
MC39-1-F-UNNU MC39-1-J-UNNU
3.45 x 3.13 x 1.27 4.04 x 3.0 x 1.21
QT1x70MH SQ QT1x70MH SQ
3.5 x 3.0 x 1.54 5.0 x 1.8 x 1.3 5.0 x 1.8 x 1.3 5.0 x 1.8 x 1.3 5.0 x 1.8 x 1.3
MC70-1-F-UNNU MC70-1-J-UNNU
3.45 x 3.13 x 1.27 7.74 x 1.74 x 1.47 7.74 x 1.74 x 1.47 7.74 x 1.74 x 1.47 7.74 x 1.74 x 1.47
QTP1X70MH UNV SLIM F QTP1X70MH UNV SLIM J QTP1X100MH UNV SLIM F QTP1X100MH UNV SLIM J
E L E C T R O N I C B A L L A S T S
Item Number
OSRAM SYLVANIA
Mount
Advance
Metrolight
gE
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
157
Magnetic Ballast
Simplified Solutions OSRAM SYLVANIA is focused on helping our customers understand our products, and to simplifying their use and applications. SYLVANIA magnetic fluorescent product labels include an industry first cross-reference guide to help identify the proper ballast for replacing existing installed products. The line voltage is also clearly identified to ensure proper application, and our shipping carton labels are also color coded to indicate the voltage to help avoid misapplication even before the ballasts are out of the box. SYLVANIA magnetic HID ballast descriptions are based on the corresponding lamp description to make lamp/ballast matching and identification easier. All fluorescent and HID carton labels also identify the corresponding lamp/ ballast matching to make proper product selection as clear and as simple as possible.
Magnetic Fluorescent Ballasts High quality products for most general applications i.e. T12, T9, T8 and T5 lamps Magnetic Fluorescent Sign Ballasts
F-Can HID Ballasts F-Can ballasts for indoor applications operate a range of metal halide, pulse start metal halide and high pressure sodium lamps with minimal noise.
Magnetic Ballasts OSRAM SYLVANIA offers a wide range of magnetic ballast products to support our customers with SYLVANIA brand lighting products. This array of products will allow our customers a broad selection of magnetic ballasts to choose from to operate their SYLVANIA brand lamps. HID Magnetic SUPER 5 Kits Magnetic Fluorescent Sign Ballasts Pulse Start HID Ballasts F-Can HID Ballasts Indoor Enclosed HID Ballasts
T12 high output magnetic ballasts for sign applications are designed to meet or exceed industry standards and requirements for the sign business. HID Magnetic Ballast Kits Easy to use replacement kits for the range of metal halide, pulse start metal halide, high pressure sodium and mercury lamps. Kits include core and coil, capacitors and ignitors (where required), brackets and mounting hardware. Our SUPER 5 HID Kits have 120, 208, 240, 277 and 480V input voltage taps to reduce the number of models in inventory.
METALARC Indoor Enclosed HID Ballasts Indoor Enclosed ballasts for indoor applications where remote mounting is required.
158
www.sylvania.com
2000 Federal Ballast Efficacy Regulations Ballast manufacturers cannot manufacture fluorescent ballasts for Full-Wattage F40T12, F40T12/U, F96T12 and F96T12HO that do not meet the minimum Ballast Efficacy Factor (BEF) after July 1, 2010.
EPAct 2005 Magnetic Fluorescent Ballasts Ballast manufacturers cannot manufacture fluorescent ballasts for Energy-Saving F40T12, F40T12/U, F96T12 and F96T12HO that do not meet the minimum Ballast Efficacy Factor (BEF) after July 1, 2010.
Discontinued List Discontinued Products Nearest Electronic Replacement T12 and T12HO Fluorescent Ballasts
48011 48120 48001 48121 48018 48124 48125 48126 48025 48027 48127 48128 MB1x40/120RS-SRNK MB1x40/277RS-SRNK MB2x40/120RS-SRNK MB2x40/277RS-SRNK MB2x96/120IS-SRNK MB1x96/120IS-SRNK MB1x96/277IS-SRNK MB2x96/277IS-SRNK MB2x96/HO/120RS-SRNK MB2x96/HO/277RS-SRNK MB1x96/HO/120RS-SRNK MB1x96/HO/277RS-SRNK T8 Upsell 49905 ballast & lamp 21763 T8 Upsell 49905 ballast & lamp 21763 50314 50314 50308 50308 50308 50308 50319 50319 50319 50319 QTP1x32T8/UNV ISN-SC & FO32/835/XP/ECO QTP1x32T8/UNV ISN-SC & FO32/835/XP/ECO QTP2x40T12/UNV RS 4 Pack QTP2x40T12/UNV RS 4 Pack QTP2x96T12/UNV IS 3 Pack QTP2x96T12/UNV IS 3 Pack* QTP2x96T12/UNV IS 3 Pack* QTP2x96T12/UNV IS 3 Pack QTP2x96T12HO/UNV RS 6 Pack QTP2x96T12HO/UNV RS 6 Pack QTP2x96T12HO/UNV RS 6 Pack* QTP2x96T12HO/UNV RS 6 Pack*
159
www.sylvania.com
Action
2005 BEF Standards for Full-Wattage T12 Lamps (F40T12, F40T12/U, F96T12 and F96T12HO)
2009 BEF Standards for Energy-Saving T12 Lamps (F40T12, F40T12/U, F96T12 and F96T12HO)
Ballast manufacturers can no longer make ballasts that do not pass the new requirements for use in new fixtures. Ballast manufacturers cannot sell ballasts that do not pass the new requirements to US fixture manufacturers. Fixture manufacturers cannot sell fixtures that include ballasts that do not pass the new requirements.
April 1, 2005
July 1, 2009
July 1, 2005
October 1, 2009
April 1, 2006
July 1, 2010
160
T8 RAPID START
F017T8 Rapid Start High Power Factor 48312 MB1x17/120RS 120 1 F017T8, FB016T8/U 31 R1P817TP 707TCP 8G4177W
F40T12 Rapid Start Normal Power Factor - For Residential Use Only 48210 MB1x40/120RES-SRNK 120 1 31 RL140TP 413CTCP 8G1075
48151
MB1/2x48/96/HO/120RS-SRNK/IN
120
1 or 2
154
RS110TP
490XLHTCP
T12/HO Sign Ballasts 48204 MSB-12-0412-TP 120 1-2 185 ASB-0412-12-BL-TP USB-0412-12 6G3901WF
48205
MSB-24-0620-TP
120
2-4
300 ASB-0620-24-BL-TP
USB-0816-14
6G3814WF
48206
MSB-24-1224-TP
120
2-4
375 ASB-1224-24-BL-TP
USB-1024-14
6G3959WF
M A g N E T I C B A L L A S T S
48207
MSB-24-2040-TP
120
2-4
470 ASB-2040-24-BL-TP
USB-1632-24
6G3782WF
48208
MSB-46-1240-TP
120
4-6
415 ASB-1240-46-BL-TP
USB-2036-46
6G3787AWF
48209
MSB-46-2448-TP
120
4-6
540 ASB-2448-46-BL-TP
USB-2048-46
6G3942AW
Input Power (Watts) for primary lamp type and SUPERSAVER equivalent, (where applicable). Primary lamp type and SUPERSAVER equivalent in bold print. This product line guide is intended as an aid for identifying comparable products for the lamp types listed as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes, wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Refer to SYLVANIA Sign Ballast Specification Sheet for detailed lamp configuration. Maximum Input Power (Watts) are listed. Nearest Equivalent Performance specifications may vary, please refer to manufacturers specifications. Due to EPAct 2005, MB1/2x48/96/HO/120RS-SRNK/IN ballast can operate only 1-lamp F96T12/HO.
3 4 5
More complete product information is available in the SYLVANIA Magnetic Ballast Catalog or at www.sylvania.com. *DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
161
1 1 2 2
F96T12/VHO, F96T12/VHO/SS(195W), F72T12/VHO, F60T12/VHO, F48T12/VHO F96T12/VHO, F96T12/VHO/SS(195W), F72T12/VHO, F60T12/VHO, F48T12/VHO F96T12/VHO, F96T12/VHO/SS(195W), F72T12/VHO, F60T12/VHO, F48T12/VHO F96T12/VHO, F96T12/VHO/SS(195W), F72T12/VHO, F60T12/VHO, F48T12/VHO
Input Power (Watts) for primary lamp type and SUPERSAVER equivalent, (where applicable). Primary lamp type and SUPERSAVER equivalent in bold print. This product line guide is intended as an aid for identifying comparable products for the lamp types listed as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes, wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Refer to SYLVANIA Sign Ballast Specification Sheet for detailed lamp configuration. Maximum Input Power (Watts) are listed. Nearest Equivalent - Performance specifications may vary, please refer to manufacturers specifications. Due to Energy Policy ACT 2005, MB1/2x48/96/HO/120RS-SRNK/IN ballast can operate only 1-lamp F96T12/HO.
3 4 5
More complete product information is available in the SYLVANIA Magnetic Ballast Catalog or at www.sylvania.com. *DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
M A g N E T I C B A L L A S T S
162
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
M A g N E T I C B A L L A S T S
J-BOX COVER
For Sign & F-Can Ballasts 48275
1 2
JBox Cover
PC-875W
* Formerly MagneTek Lighting Input Power (Watts) for primary lamp type and SUPERSAVER equivalent, (where applicable). Primary lamp type and SUPERSAVER equivalent in bold print. This product line guide is intended as an aid for identifying comparable products for the lamp types listed as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes, wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Refer to SYLVANIA Sign Ballast Specification Sheet for detailed lamp configuration. Maximum Input Power (Watts) are listed. Nearest Equivalent Performance specifications may vary, please refer to manufacturers specifications. Due to Energy Policy ACT 2005, MB1/2x48/96/HO/120RS-SRNK/IN ballast can operate only 1-lamp F96T12/HO.
3 4 5
More complete product information is available in the SYLVANIA Magnetic Ballast Catalog or at www.sylvania.com. *DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
163
MAGNETIC HID
Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Circuit Type Input Power (Watts) ADVANCE Catalog #8 Universal Lighting Technologies* Catalog #8 Venture Lighting Catalog #8 Howard Industries Catalog #8,9
M A g N E T I C B A L L A S T S
400W Metal Halide Lamp ANSI Code M59 47338 47739 47065 M400/SUPER5-KIT M400/MULTI-KIT M400/480-KIT 120/208/ 240/277/480 120/208/ 240/277 480 CWA CWA CWA 458 458 458 M400ML5AC4M & M400ML5AC4M-500K M400MLTAC4M & M400MLTAC4M-500K M400480AC4M V90D6413K M040081C211 M040071C211 M040011C211
1000W Metal Halide Lamp ANSI Code M47 47427 47744 47655 M1000/SUPER5-KIT M1000/MULTI-KIT M1000/480-KIT 120/208/ 240/277/480 120/208/ 240/277 480 CWA CWA CWA 1080 1080 1080 M1000ML5AC5M & V90AM6514K M1000ML5AC5M-500K M1000MLTAC5M & V90D6514K M1000MLTAC5M-500K M1000480AC5M & M1000480AC5M-500K M1500MLTAC5M & M1500MLTAC5M-500K M1500480AC5M & M1500480AC5M-500K V90D6612K M0100071C212 M0100011C212
1500W Metal Halide Lamp ANSI Code M48 46808 47095 M1500/MULTI-KIT M1500/480-KIT 120/208/ 240/277 480 CWA CWA 1605 1605 M0150071C212 M0150011C212
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
Footnotes on page 174 All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
164
MAGNETIC HID
Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Circuit Type Input Power (Watts) ADVANCE Catalog #8 Universal Lighting Technologies* Catalog #8 Venture Lighting Catalog #8 Howard Industries Catalog #8,9
METALARC METAL HALIDE PULSE START CORE & COIL BALLAST KITS
35W Metal Halide Pulse Start Lamp ANSI Code M130 47001 47203 47007 47204 M35/MULTI-HQ/CI-KIT M35/120/277-KIT M50/MULTI-KIT M50/120/277-KIT 120/208/ 240/277 120/277 120/208/ 240/277 120/277 CWA HX-HPF HX-HPF HX-HPF 58 54 67 67 71A5081 71A5181 & 71A5181-001D 71A5292 & 71A5292-001D 71A5282 M50MLTLC3M & M50MLTLC3M-500K V90D5731K V90H5731K
70W Metal Halide Pulse Start Lamp ANSI Code M98 47013 47217 47645 M70/MULTI-KIT M70/120/277-KIT M70/MULTI-HQ/CI-KIT 120/208/ 240/277 120/277 120/208/ 240/277 120/208/ 240/277 120/277 HX-HPF HX-HPF CWA 95 95 95 M70MLTLC3M & M70MLTLC3M-500K V90D5832K V90H5832K V90D5810K
70W Metal Halide Pulse Start Lamp ANSI Code M98 or M139 or M85
100W Metal Halide Pulse Start Lamp ANSI Code M90 47019 47219 M100/MULTI-KIT M100/120/277-KIT HX-HPF HX-HPF 130 130 71A5390 & 71A5390-001D 71A5380 M100MLTLC3M & M100MLTLC3M-500K V90D5932K V90H5932K M010071C511
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
M A g N E T I C B A L L A S T S
Footnotes on page 174 All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
165
MAGNETIC HID
Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Circuit Type Input Power (Watts) ADVANCE Catalog #8 Universal Lighting Technologies* Catalog #8 Venture Lighting Catalog #8 Howard Industries Catalog #8,9
150W Metal Halide Pulse Start Lamp ANSI Code M102 47682 47228 47640 M150/MULTI-PS-KIT M150/120/277-PS-KIT M150/MULTI-PS-CWA-KIT 120/208/ 240/277 120/277 120/208/ 240/277 120/208/ 240/277 120/208/ 240/277 120/208/ 240/277 480 480/120TAP HX-HPF HX-HPF CWA 185 185 189 71A5492 & 71A5492-001D 71A5482 M150MLTLC3M & M150MLTLC3M-500K V90D7130K V90D7110K
150W Metal Halide Pulse Start Lamp ANSI Code M102 or M142
150W Metal Halide Pulse Start Lamp ANSI Code M81 47229 M150/MULTI-KIT HX-HPF 185 71A5490 M150MLTLC3D & M150MLTLC3D-500K P175MLTAC3M & P175MLTAC3M-500K P200MLTAC3M & P200MLTAC3M-500K P20048TAC3M & P20048TAC3M-500K P250ML5AC4M P250MLTAC4M & P250MLTAC4M-500K P320MLTAC4M & P320MLTAC4M-500K P32048TAC4M & P32048TAC4M-500K P350MLTAC4M & P350MLTAC4M-500K P400ML5AC4M P400MLTAC4M & P400MLTAC4M-500K P40048TAC4M & P40048TAC4M-500K
175W Metal Halide Pulse Start Lamp ANSI Code M137 or M152 47686 M175/MULTI-PS-KIT CWA 208 71A5593 & 71A5593-001D 71A5692 & 71A5692-001D 71A5642T V90D7210K
200W Metal Halide Pulse Start Lamp ANSI Code M136 47690 46802 47259 M200/MULTI-PS-KIT M200/480-PS-KIT M200/480/120T-PS-KIT CWA CWA CWA 232 232 232 V90D7310K V90Y7310TK M020071C611 M020011C611 M020029C611
M A g N E T I C B A L L A S T S
250W HQI Metal Halide Lamp ANSI Code M80 47273 47282 47112 M250/120/277-KIT M250/SUPER5-PS-KIT M250/MULTI-PS-KIT 120/277 120/208/ 240/277/480 120/208/ 240/277 120/208/ 240/277 480 480/120TAP HX-HPF CWA CWA 290 288 288 71A5880 71A5792 & 71A5792-001D 71A5892 & 71A5892-001D 71A5842T & 71A5842-001D T 71A5993 & 71A5993-001D 71A6092 & 71A6092-001D 71A6042T V90D8410K M025071C611 250W Metal Halide Pulse Start Lamp ANSI Code M138 or M153
320W Metal Halide Pulse Start Lamp ANSI Code M132 or M154 47676 46803 47303 M320/MULTI-PS-KIT M320/480-PS-KIT M320/480/120T-PS-KIT CWA CWA CWA 368 368 368 V90D7411K V90Y7411TK M032071C611
350W Metal Halide Pulse Start Lamp ANSI Code M131 47695 47697 47400 47132 47138 47403 M350/MULTI-PS-KIT M350/480-PS-KIT M400/SUPER5-PS-KIT M400/MULTI-PS-KIT M400/480-PS-KIT M400/480/120T-PS-KIT 120/208/ 240/277 480 120/208/ 240/277/480 120/208/ 240/277 480 480/120TAP CWA CWA CWA CWA CWA CWA 400 400 452 452 452 452 V90D7512K V90D7612K V90Y7612TK M035071C611 M040071C611 M040011C611 M040029C611
400W Metal Halide Pulse Start Lamp ANSI Code M155 or M135
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
166
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
MAGNETIC HID
Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Circuit Type Input Power (Watts) ADVANCE Catalog #8 Universal Lighting Technologies* Catalog #8 Venture Lighting Catalog #8 Howard Industries Catalog #8,9
750W Metal Halide Pulse Start Lamp ANSI Code M149 47717 47409 47718 47416 47417 46805 M750/MULTI-PS-KIT M750/120/277/347/480-PS-KIT M750/480-PS-KIT M1000/MULTI-PS-KIT M1000/120/277/347/480-PS-KIT M1000/480-PS-KIT 120/208/ 240/277 120/277/ 347/480 480 120/208/ 240/277 120/277/ 347/480 480 CWA CWA CWA CWA CWA CWA 818 818 818 1080 1080 1080 71A64E26,7 71A64F2T6,7 71A65936 71A65F3T6,7 P750MLTAC5M & P750MLTAC5M-500K P1000MLTAC5M & P1000MLTAC5M-500K V90D7910K V90J7910K7 V90D7810K V90J7810K7
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
M A g N E T I C B A L L A S T S
Footnotes on page 174 All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
167
MAGNETIC HID
Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Circuit Type Input Power (Watts) ADVANCE Catalog #8 Universal Lighting Technologies* Catalog #8 Venture Lighting Catalog #8 Howard Industries Catalog #8,9
M A g N E T I C B A L L A S T S
70W High Pressure Sodium Lamp ANSI Code S62 47301 47579 47571 47316 47593 47592 47335 47619 47617 LU70/MULTI-KIT LU70/480-KIT LU70/120/277-KIT LU100/MULTI-KIT LU100/480-KIT LU100/120/277-KIT LU150/MULTI-KIT LU150/480-KIT LU150/120/277-KIT 120/208/ 240/277 480 120/277 120/208/ 240/277 480 120/277 120/208/ 240/277 480 120/277 HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF HX-HPF 91 91 91 128 128 128 188 188 188 S70MLTLC3M & S70MLTLC3M-500K S100MLTLC3M & S100MLTLC3M-500K S150MLTLC3M & S150MLTLC3M-500K V90D1233K V90D1333K V90D1435K S007071C511 S010071C511 S015071C511
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
168
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
MAGNETIC HID
Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Circuit Type Input Power (Watts) ADVANCE Catalog #8 Universal Lighting Technologies* Catalog #8 Venture Lighting Catalog #8 Howard Industries Catalog #8,9
250W High Pressure Sodium Lamp ANSI Code S50 47634 47357 47358 LU250/SUPER5-KIT LU250/MULTI-KIT LU250/480-KIT 120/208/ 240/277/480 120/208/ 240/277 480 CWA CWA CWA 295 295 295 S250ML5AC4M & S250ML5AC4M-500K S250MLTAC4M & S250MLTAC4M-500K V90D1711K S025081C211 S025071C211
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
M A g N E T I C B A L L A S T S
Footnotes on page 174 All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
169
MAGNETIC HID
Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Circuit Type Input Power (Watts) ADVANCE Catalog #8 Universal Lighting Technologies* Catalog #8 Venture Lighting Catalog #8 Howard Industries Catalog #8,9
310W High Pressure Sodium Lamp ANSI Code S67 47643 LU310/MULTI-KIT 120/208/ 240/277 120/208/ 240/277/480 120/208/ 240/277 480 480/120TAP CWA 355 71A8391 & 71A8371-001D 71A8453 & 71A8453-001D 71A8493 & 71A8473-001D 71A8443 & 71A8443-001D 71A8443T V90D1810K
400W High Pressure Sodium Lamp ANSI Code S51 47647 47364 47376 47657 LU400/SUPER5-KIT LU400/MULTI-KIT LU400/480-KIT LU400/480/120T-KIT CWA CWA CWA CWA 464 464 464 464 S400ML5AC4M & S400ML5AC4M-500K S400MLTAC4M & S400MLTAC4M-500K S40048TAC4M & S40048TAC4M-500K S1000ML5AC5M & S1000ML5AC5M-500K S1000MLTAC5M & S1000MLTAC5M-500K V90D1911K & V90D1912K S040071C211 S040011C211
750W High Pressure Sodium Lamp ANSI Code S111 47712 47658 47659 LU750/MULTI-KIT LU750/480-KIT LU1000/SUPER5-KIT LU1000/MULTI-KIT LU1000/480-KIT 120/208/ 240/277 480 120/208/ 240/277/480 120/208/ 240/277 480 CWA CWA CWA CWA CWA 830 830 1100 1100 1100 71A86E56,7 71A87536 & 71A8753-0016 71A87936 & 71A8773-0016 71A87436 & 71A8743-0016 V90D2311K S100071C211 S100011C211
M A g N E T I C B A L L A S T S
47389 47391
250W Metal Halide Lamp ANSI Code M58 47751 M250/120/277/F-CAN 120/277 CWA 295 1110-246C-TC4
400W Metal Halide Lamp or 360W Metal Halide Lamp10 ANSI Code M59 47759 M400/120/277/F-CAN 120/277 CWA 460 1110-247SC-TC
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
170
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
MAGNETIC HID
Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Circuit Type Input Power (Watts) ADVANCE Catalog #8 Universal Lighting Technologies* Catalog #8 Venture Lighting Catalog #8 Howard Industries Catalog #8,9
70W Metal Halide Pulse Start Lamp ANSI Code M139 47693 47694 M70/120/277/F-CAN M70/120/277/F-CAN 120/277 120/277 HX-HPF HX-HPF 95 94 11210-506C-TC 70W Metal Halide Pulse Start Lamp ANSI Code M98 or M143
100W Metal Halide Pulse Start Lamp ANSI Code M90 47734 M100/120/277/F-CAN 120/277 HX-HPF 125 11210-239C-TC
250W Metal Halide Pulse Start Lamp ANSI Code M138 or M153 47749 M250-PS/120/277/F-CAN 120/277 CWA 295
M A g N E T I C B A L L A S T S
320W Metal Halide Pulse Start Lamp ANSI Code M132 or M154 47753 M320-PS/120/277/F-CAN 120/277 CWA 375 P320277AFXM
400W Metal Halide Pulse Start Lamp ANSI Code M155 or M135 47757 M400-PS/120/277/F-CAN 120/277 CWA 465
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
Footnotes on page 174 All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
171
MAGNETIC HID
Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Circuit Type Input Power (Watts) ADVANCE Catalog #8 Universal Lighting Technologies* Catalog #8 Venture Lighting Catalog #8 Howard Industries Catalog #8,9
70W High Pressure Sodium Lamp ANSI Code S62 47763 LU70/120/277/F-CAN 120/277 HX-HPF 90 12210-237C-TC
100W High Pressure Sodium Lamp ANSI Code S54 47764 LU100/120/277/F-CAN 120/277 HX-HPF 125 12210-239C-TC
150W High Pressure Sodium Lamp ANSI Code S55 47765 47777 LU150/120/277/F-CAN LU250/120/277/F-CAN 120/277 120/277 HX-HPF CWA 185 298 12210-241C-TC 1220-246C-TC 250W High Pressure Sodium Lamp ANSI Code S50
400W Metal Halide Lamp or 360W Metal Halide Lamp10 ANSI Code M59 47172 M400/MULTI-I/D CWA 458 78E6091-001
1000W Metal Halide Lamp ANSI Code M47 47207 M1000/MULTI-I/D CWA 1080 78E6592-001
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
172
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
MAGNETIC HID
Item Number OSRAM SYLVANIA Description Input Voltage (VAC) Circuit Type Input Power (Watts) ANSI Code
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
M A g N E T I C B A L L A S T S
Footnotes on page 174 All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
173
MAGNETIC HID
REPLACEMENT IgNITORS FOR SYLVANIA HID BALLASTS11: 48153 48154 48155 47843 47844 47847 47982 47988 47986 47987 47895 FOOTNOTES * Formerly MagneTek Lighting 4 NEAREST EQUIVALENT Performance specifications may vary, please refer to manufacturers specifications. 5 R-INT = Reactor with Integral Ignitor. 6 OSRAM SYLVANIAS HID Ballast is UL Class H Rated and can be used with the corresponding UL Rated fixtures only. The ADVANCE Ballast listed is Dual Rated UL Class H and N. 7 Ballast Voltage may vary. Always check for required lamp and voltage. 8 This product line guide is intended as an aid for identifying comparable products for the lamp types, ANSI Codes and Voltage listed as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes, wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. 9 Replacement Kit is indicated by a K at the end of the catalog number. 10 A 360W Metal Halide lamp ANSI Code M59 operated on this ballast will result in approximately a 10% reduction in Input Power (Watts). 11 Only use with the corresponding SYLVANIA HID Ballasts. Please refer to OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. HID Core & Coil Ballast Kits include ignitor where applicable, capacitor where applicable, mounting bracket, hardware and installation instructions. More complete product information is available in the SYLVANIA Magnetic Ballast Catalog or at www.sylvania.com.
*DISCLAIMER: This cross reference guide is intended as an aid for identifying comparable products as a convenience to the user. OSRAM SYLVANIA does not warrant or guarantee the accuracy or correctness of the content. Case sizes,wiring diagrams and performance specifications may vary, please refer to manufacturers specifications. Please refer to the OSRAM SYLVANIA catalog for verification of product specifications appropriate for the application. Information in this cross reference is subject to change at any time without prior notice. Please contact 1-800-LIGHTBULB or www.sylvania.com for additional information.
Ignitor/MH/PS/35-150 SD Ignitor/MH/PS/175-400 SD Ignitor/MH/PS/750 SD Ignitor/HPS/50-150 Ignitor/HPS/200-400 Ignitor/HPS/750 CAP24MFD480VAC CAP26MFD540VAC CAP55MFD240VAC CAP10MFD400VAC CAP15MFD400VAC
REPLACEMENT CAPACITORS FOR SYLVANIA HID BALLASTS: formerly formerly formerly formerly formerly 47912 47920 47942 47952 47954 CAP 24Mfd 480VAC CAP 26Mfd 525VAC CAP 55Mfd 300VAC CAP 10Mfd 400VAC CAP 15Mfd 400VAC
M A g N E T I C B A L L A S T S
174
All data shown is for primary lamp types only. Complete data is available in the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide and at www.sylvania.com Specifications subject to change without notice. OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
CONTROLS
Controls
Photosensor and Control for Daylight Harvesting (0-10V)
Controls
ELOGICTM Lighting Control: Photosensor and Control for Daylight Harvesting
Item Number 45030 OSRAM SYLVANIA Description ELSC-DLH-TVLAMP/BUS
0-10V Control
Max. Input Current (mA) 6 Lamp Type T8 or T5 or T5HO
Color White
0-10V controls are compatible with QUICKTRONIC HELIOS and POWERSENSE ballast families.
ELOGICTM Lighting Controls: Occupancy Sensors and Controls with Daylight Harvesting
Item Number 45032 45033 45034 45035 OSRAM SYLVANIA Description ELSC-DLOCIRM-TV1RCEIL/UNV ELSC-DLOCIR-TV1RCEIL/UNV ELSC-DLOCIRM-TV1RREC/UNV ELSC-DLOCIR-TV1RREC/UNV
0-10V Control
Daylight Harvesting Method Photosensor with Automatic Calibration Photosensor with Automatic Calibration Photosensor with Automatic Calibration Photosensor with Automatic Calibration
Occupancy Sensing Method Passive Infrared, Microphonics Sensing Passive Infrared Passive Infrared, Microphonics Sensing Passive Infrared
Sensor Power Line Powered, No Power Pack Required Line Powered, No Power Pack Required Line Powered, No Power Pack Required Line Powered, No Power Pack Required
0-10V controls are compatible with QUICKTRONIC HELIOS and POWERSENSE ballast families.
ELOGICTM Lighting Controls: Fluorescent Single Pole and 3-Way Phase-Cut Dimmers
Item Number 45039 45040 OSRAM SYLVANIA Description ELMC-SL3W-FLPCWALL/120-IV ELMC-SL3W-FLPCWALL/277-IV ELMC-SL3W-FLPCWALL/120-WH ELMC-SL3W-FLPCWALL/277-WH ELMC-SL-FLPCWALL/120-IV ELMC-SL-FLPCWALL/277-IV ELMC-SL-FLPCWALL/120-WH ELMC-SL-FLPCWALL/277-WH Device Type Manual Control Slide Manual Control Slide Manual Control Slide Manual Control Slide Manual Control Slide Manual Control Slide Manual Control Slide Manual Control Slide
Fluorescent Dimmer
Input Voltage (VAC) 120 277 120 277 120 277 120 277 Integral Switch 3-Way 3-Way 3-Way 3-Way Single Pole Single Pole Single Pole Single Pole
Ballast Control Method Fluorescent Phase Cut Dimmer Fluorescent Phase Cut Dimmer Fluorescent Phase Cut Dimmer Fluorescent Phase Cut Dimmer Fluorescent Phase Cut Dimmer Fluorescent Phase Cut Dimmer Fluorescent Phase Cut Dimmer Fluorescent Phase Cut Dimmer
Maximum Input Current (A) (# of gangs) Single Double Triple 5.0A 2.2A 5.0A 2.2A 5.0A 2.2A 5.0A 2.2A 4.5A 2.0A 4.5A 2.0A 4.5A 2.0A 4.5A 2.0A 4.0A 1.7A 4.0A 1.7A 4.0A 1.7A 4.0A 1.7A
C O N T R O L S
Fluorescent phase-cut dimmers are compatible with QUICKTRONIC POWERSENSE ballast family.
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
176
High Efficiency PowerSHEDTM Load Shed (100% to ~67% Power) Universal Voltage (120-277VAC) T8 Instant Start Electronic Ballasts
System Power Input System1 Saved in Power Efficacy Load Shed (W) (lm/W) BEF2 (W) 56/55 38/38 56/55 38/38 53/53 36/36 48/48 33/33 43/43 29/30 31/30 21/22 83/82 56 83/82 56 78/77 53 73/72 49/50 63/62 42/43 45 31/32 88 94 92 99 92 81 1.60 18/17 1.60 18/17 1.66 17/17 1.79 15/15 2.09 14/13 2.95 10/8 89/90 1.07 27/26 95/97 1.07 27/26 96/98 1.14 25/24 100 1.22 24/22 91/93 1.42 21/19 81 1.96 14/13
Lamp Type FO32/700 FO32/800/XP FO30/800/XP/SS FO28/800/XP/SS FO25/835/XP (3) FO17/835/XP (2)
No. of Lamps 2 2 2 2 2 2 3 3 3 3 3 3
Mode Normal Load Shed Normal Load Shed Normal Load Shed Normal Load Shed Normal Load Shed Normal Load Shed Normal Load Shed Normal Load Shed Normal Load Shed Normal Load Shed Normal Load Shed Normal Load Shed
Input Current (AMPS) 0.47/0.20 0.47/0.20 0.44/0.19 0.40/0.18 0.38/0.17 0.27/0.12 0.69/0.30 0.69/0.30 0.66/0.28 0.61/0.26 0.53/0.23 0.38/0.17
Ballast Initial Mean Factor System System (BF) Lumens Lumens 0.88 0.57 0.88 0.57 0.86 0.57 0.87 0.58 0.91 0.58 0.91 0.58 0.88 0.53 0.88 0.53 0.88 0.53 0.88 0.53 0.88 0.54 0.88 0.55 4930 3190 5280 3420 4900 3250 4740 3160 3960 2525 2505 1595 7390 4450 7920 4770 7525 4530 7195 4335 5740 3525 3630 2270 4435 2875 5015 3250 4660 3090 4505 3005 3760 2395 2375 1515 6650 4005 7445 4480 7075 4260 6760 4070 5400 3310 3410 2130
50696
QHELS3x32T8/UNV ISN-SC
The PowerSHEDTM ballast reacts to the PowerSHED signal (refer to injector and coupler information) sent over the AC supply from the lighting panel and immediately sheds up to 33% of its load. Actual power and BF varies depending on lamp type. Refer to respective columns. 1 System Efficacy based on lowest Input Power. 2 Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note calculation based on lowest power value).
C O N T R O L S
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com Complete PowerSHEDTM system (ballast and controls). Details are available at www.sylvania.com
177
NOTES:
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
178
NOTES:
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com Complete PowerSHEDTM system (ballast and controls). Details are available at www.sylvania.com
179
NOTES:
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
180
NOTES:
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com Complete PowerSHEDTM system (ballast and controls). Details are available at www.sylvania.com
181
NOTES:
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
182
NOTES:
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com Complete PowerSHEDTM system (ballast and controls). Details are available at www.sylvania.com
183
NOTES:
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
184
NOTES:
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com Complete PowerSHEDTM system (ballast and controls). Details are available at www.sylvania.com
185
NOTES:
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
186
NOTES:
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com Complete PowerSHEDTM system (ballast and controls). Details are available at www.sylvania.com
187
NOTES:
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) or www.sylvania.com
188
8THS
INCHES
1/4 1/2 3/4 1
Hg LAMP CONTAINS MERCURY Manage in Accordance with Disposal Laws See: www.lamprecycle.org or 1-866-666-6850
Information in this catalog is subject to change at any time without prior notice.
_____ 1 _____ T2 _____ 3 _____ T4 _____ T5 _____ T6 _____ 7 _____ T8 _____ 9 _____ B10 _____ 11 _____ T12 _____ 13 _____ PAR14 _____ 15 MR16 _____ _____ G16 1/2 _____ A17 _____ ET18 _____ A19 PAR20 _____ _____ A21 _____ 22 _____ 23 ________________ _____ G25 _____ 26 _____ 27 _____ BT28 _____ 29 PAR30 _____ _____ 31 ________________ _____ 33 _____ 34 _____ 35 _____ 36 _____ BT37 PAR38 _____ _____ 39 R40, G40 _____ _____ 41 _____ 42 _____ 43 _____ 44 _____ 45 PAR46 _____ _____ 47 ________________ _____ 49 _____ 50 _____ 51 PAR52 _____ _____ 53 _____ 54 _____ 55 BT56/PAR56 _____ _____ 57 _____ 58 _____ 59 _____ 60 _____ 61 _____ 62 _____ 63 PAR64 _____ _____ 65 _____ 66 _____ 67 _____ 68 _____ 69 _____ 70 _____ 71 ________________ _____ 73 _____ 74 _____ 75 _____ 76 _____ 77 _____ 78 _____ 79
FSC LOGO
For Orders and General Information in the United States: OSRAM SYLVANIA National Customer Service and Sales Center 18725 N. Union Street Westfield, IN 46074 United States OSRAM SYLVANIA Headquarters 100 Endicott Street Danvers, MA 01923 USA 1-800-LIGHTBULB www.sylvania.com
Canada OSRAM SYLVANIA LTD./LTE Headquarters 2001 Drew Road Mississauga, ON L5S 1S4 1-800-LIGHTBULB www.sylvania.com 1-800-255-5042 1-800-255-5043 Trade Phone: Fax: 1-800-263-2852 1-800-667-6772
National Accounts Phone: 1-800-562-4671 Fax: 1-800-562-4674 OEM/Special Markets Phone: 1-800-762-7191 Fax: 1-800-762-7192 Retail Phone: Fax: 1-800-842-7010 1-800-842-7011
OEM/Special Markets/Display/Optic Phone: 1-800-265-2852 Fax: 1-800-667-6772 Retail Phone: Fax: 1-800-720-2852 1-800-667-6772
Display/Optic Phone: 1-888-677-2627 Fax: 1-800-762-7192 SYLVANIA Lighting Services Phone: 1-800-323-0572 Fax: 1-800-537-0784
CURVALUME, DESIGNER, DESIGN 50, DESIGNER PLUS, ECO, ECOLOGIC, EXCEL-LINE, Fixtureside Assistance, GRO-LUX, ICETRON, LUMALUX, LUMALUX PLUS, METALARC, METALARC PRO-TECH, OCTRON, PENTRON, PLANTASTAR, PROSTART, QUICKSENSE, QUICK 60+, QUICKSTEP, SAFELINE, SEE THE WORLD IN A NEW LIGHT, SUNSTICK, SUPERSAVER, SUPERSAVER PLUS, SYLVANIA, The System Solution and Squiggle Logo, UNALUX, XP and XPS are registered trademarks of OSRAM SYLVANIA Inc. HELIOS, POWERSENSE and PowerSHED are trademarks of OSRAM SYLVANIA Inc. ELOGIC is a trademark or a registered trademark of OSRAM SYLVANIA Inc. HQI, LINESTRA, POWERBALL, QUICKTRONIC are registered trademarks of OSRAM GmBH. All other trademarks are property of their respective owners. Product specifications are subject to change without notice. Photographs are exemplary of possible applications for the lamps and not photographs depicting the lamps in use.
PRODUCT-CAT-LAMP-BALLAST 7-11
Certain Photography