Nothing Special   »   [go: up one dir, main page]

CHP-CMM, CHP-SMM Management Modules Data Sheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

DATA SHEET

CHP Max Headend Optics Platform


CHP-CMM-1, CHP-SMM-2
Control Modules

FEATURES CommScope products and solutions can help cable operators attain 
new subscriber revenue and higher average revenue per subscriber 
• Optimize headend and hub efficiencies with  without major CAPEX. Cable operators can seamlessly and easily stay in 
industry leading density and low power  line with future goals, add new services, and strongly position against 
consumption up to 20 transmitters or 40  the competition.
receivers per 2RU chassis As part of the CHP Max Headend Optics Platform, CHP Max5000®
• Up to 44 full‐spectrum wavelengths for  headend chassis applications unite HFC and digital transport onto a 
harvesting new bandwidth through node  single scalable system, allowing service providers to accelerate 
segmentation deployment of VOD, high‐speed data, telephony, and other advanced 
• Support multiple optical architectures including  services in a space‐saving footprint.
full spectrum, overlay, and RFoG
• DOCSIS® 3.1 support for future capacity 
expansion to 1.2 GHz downstream, 300 MHz 
upstream
• Transmitters with variable output reduce need 
for troublesome optical attenuators 
• Front or rear fiber connection simplifies 
installation and cable management 
• Configure, monitor, and manage with CORView™
Element Management System

1 CHP-CMM-1, CHP-SMM-2 © 2022 CommScope, Inc. All rights reserved.


CHP Max5000 Management Modules

The CHP Max5000 Craft Management Module (CMM) offers local compatible graphical user interface (GUI). The CHP Max5000 
GUI simplifies installation, provides monitoring on easy‐to‐read screens, and displays all critical module information to assist in 
operational management. 

The System Management Module (SMM) offers all the functionality of the CMM plus remote management through the Ethernet 
interface, using SNMP with HMS‐compliant MIBs to interface with external element managers. The SMM also provides remote 
access to the CMM using an IP connection through the Ethernet interface from the remote GUI software, eliminating the need for 
an SNMP element manager. Both management modules offer an RS‐485 interface, which interconnects multiple chassis at one 
site for single point control from an SMM. The SMM provides SNMP access for remote management and monitoring of the CHP 
Max5000 Headend equipment via both HMS public domain and enterprise MIBs. 

To monitor up to 10 chassis, operators can install one CMM in up to nine chassis and one SMM in a tenth chassis. The operator
can then daisy chain the 10 chassis and use the Ethernet connection on the back of the SMM‐2 chassis to program, provision, 
monitor, and manage the CHP Max5000 equipment via an SNMP element manager. To manage more than 10 chassis, operators 
can use a 10Base‐T Ethernet hub or switch between the Remote Management System and the chassis that contains the SMM 
Module. 

The System Management Module (SMM‐2) supports feature‐rich modules such as CHP CORWave® II and CORWave 3 full spectrum 
C‐Band forward transmitters and CHP digital return receivers. Operators can enable backward compatibility with legacy modules 
through regularly scheduled software releases provided by CommScope. Please contact your CommScope Representative to be 
sure you are receiving regularly scheduled updates. 

CMM AND SMM SPECIFICATIONS 
Characteristics Specification
Environmental
Operating Temperature Range 0° to 50°C (32° to 122°F) 
Storage Temperature Range ‐40° to 70°C (‐40° to 158°F)
General
RS‐232 38.4 kbps
RS‐485 (Shelf Interconnect, RJ‐14 Connectors on Chassis) 38.4 kbps
Craft Interface Port (DB‐9 Female) RS‐232
RS‐232 Debugging Port (SMM only) 19.2 kbps
RJ‐45 (Ethernet) 10 Mbps
Serial Peripheral Interface Bus 480 kbps
Power Requirements
Power Consumption
CMM 1.2 W
SMM 2.5 W

2 CHP-CMM-1, CHP-SMM-2 © 2022 CommScope, Inc. All rights reserved.


ORDERING INFORMATION 
Management Module Model Name Description
Craft Management Module CHP‐CMM‐1 Allows local monitoring and management via laptop computer connected to the RS‐232 
connector on the front of the CMM‐1.
System Management Module CHP‐SMM‐2 Provides all CMM functionality and SNMP port for remote management. Also provides remote 
access to the CMM interface using an IP connection through the Ethernet interface on the back 
of the shelf from the remote GUI software.

RELATED PRODUCTS
CHP Chassis CHP Transmitters
CHP Power Supply Optical Passives
CHP Receivers Installation Services

Contact Customer Care for product information and sales:
• United States: 866‐36‐ARRIS
• International: +1‐678‐473‐5656

Note: Specifications are subject to change without notice.
Copyright Statement: © 2022 CommScope, Inc. All rights reserved. ARRIS, the ARRIS logo, CHP Max5000, CORView, and CORWave are trademarks of CommScope, Inc. and/or its affiliates. All other trademarks are the property of
their respective owners. No part of this content may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from
CommScope, Inc and/or its affiliates (“CommScope”). CommScope reserves the right to revise or change this content from time to time without obligation on the part of CommScope to provide notification of such revision or
change.
1514613_CHP‐CMM‐1, CHP‐SMM‐2_DS_RevA

3 CHP-CMM-1, CHP-SMM-2 3‐2022

You might also like