Air Conditioner: Reliability
Air Conditioner: Reliability
Air Conditioner: Reliability
NOISE WATERPROOF
TEST TEST
A resin-potted
circuit board.
Please read the Installation Instructions carefully before installing the unit,
and the Operating Instructions before using it. Do not add or replace refrigerant other
than the specified type. Manufacturer
Specifications are subject to change without prior notice.
is not responsible for the damage and
The contents of this catalogue are accurate as of December 2014. deterioration in safety due to usage of
Due to printing considerations, the actual colours may vary slightly from those shown. other refrigerant.
All graphics are provided merely for the purpose of illustrating a point.
AC-CAMB-15
+
02 - 03
04 - 05
Reliability
FUTURE, COOL
06 - 09
HOW 10 - 13 +
WOULD IT BE? 14 - 17
18 - 19
20 - 32
PRODUCT LINE-UP
PREMIUM Inverter Single - Split
Deluxe non-Inverter Single - Split
Standard non-Inverter Single - Split
Inverter Deluxe Multi - Split
Inverter Standard Single - Split
Window
Floor or Ceiling and Floor Standing
33 - 35
Features Comparison and Explanation
36 - 41
Technical Explanation
42 - 43
New Remote Control
44 - 47
POWERING A Technical Explanation
GREEN REVOLUTION. 48 - 49
Technical Explanation
HERE
FOR YOU
TODAY. THERE
4
FOR YOU TOMORROW. 5
iAUTO-X
COOLING
WHEN IT COUNTS.
COMFORT
WHEN IT MATTERS.
* Comparison of 1.5HP PREMIUM Inverter with iAUTO-X mode and Standard non-Inverter model with cooling mode
After reaching the set temperature, Shower Cooling directs airflow towards
At Panasonic Amenity Room (size: 16.6m²)
The effect differs according to conditions in installation and usage.
the ceiling to avoid direct cooling. This helps distribute cool air evenly
throughout the room, giving you longer lasting comfort.
* Please refer to page 8-9 & 36-41
Applicable to PREMIUM Inverter only.
6 7
iAUTO-X FEATURES
MORE POWER
AND MORE SPEED WITH P-TECh.
ENCY
2014 Panasonic
AX FREQU
M
DASH TO
Time (min.)
8 9
COOL. ECO.
ECONAVI+INVERTER
TOGETHER.
* Comparison of 1.5HP Inverter model with ECONAVI (with Dual Human Activity Sensor, Sunlight Sensor, and Temperature Wave) ON and 1.5HP
Standard non-Inverter (Cooling)
Inverter with ECONAVI:
ECONAVI ON, Outside Temperature: 35˚C/24˚C
Remote setting temperature: 25˚C with Fan Speed High
Horizontal Airflow direction: Step 3, Vertical Airflow direction: ECONAVI mode
Setting temperature goes up 2˚C in total, 1˚C controlled by ECONAVI activity level detection and another 1˚C controlled by ECONAVI light intensity detection.
Temperature Wave is ON
Standard non-Inverter without ECONAVI:
Outside Temperature: 35˚C/24˚C
Remote setting temperature: 25˚C with Fan Speed High
Horizontal Airflow direction: Step 3, Vertical Airflow direction: Straight
Total power consumption amount is measured for 2 hours under stable operation. At Panasonic Amenity Room (size: 16.6m²)
This is the maximum energy saving value, and the effect differs according to conditions in installation and usage.
SUNLIGHT
DETECTION
When you leave the room.
ABSENCE DETECTION
12 13
nanoe-G
When you think the air looks clean, it may already be polluted with harmful
particles less than 2.5 micrometers in size. PM 2.5 comes from motor vehicles,
factories and wood burning. Now you can purify the air in your home with
nanoe-G.
1 AIRBORNE
number of nanoe-G fine particles in the entire
room assuming they are evenly distributed.
2 DEACTIVATION OF ADHESIVE
MICRO-ORGANISMS AND 3 trillion*
DEACTIVATION
released
from the
*4 generator.
the filter. *3
Deactivates adhesive micro-organisms and nanoe-G
deodorises adhesive odours. Strike Odour Particles Decompose and Remove Odour
*4 Please refer to page 54 & 55 Bacteria & Viruses
Deactivation
16 17
TRUE COMFORT
iAUTO
IS JUST A
TOUCH AWAY
AUTOMATIC INTELLIGENCE
Equipped with the intelligence to switch between fan speeds, iAUTO gives you:
FASTER
COOLING
Voltage V 220 - 240 220 - 240 220 - 240 220 - 240 220 - 240 7 8
7 Auto comfort mode detects high activity
Electrical Data Running Current A 3.6 - 3.3 5.1 - 4.6 7.0 - 6.4 8.8 - 8.2 9.6 - 9.0 levels and switches to comfort operation
for maximum comfort.
Power Input W 730 (225-920) 1,010 (260-1,200) 1,440 (290-1,700) 1,880 (320-2,200) 2,030 (350-2,700) 10
9
L/h 1.7 2.1 2.9 3.5 4.1 8 Set the airflow.
Moisture Removal
Pt/h 3.6 4.4 6.1 7.4 8.7
11
9 Adjusts the fan speed.
m³/min. 10.1 10.9 17.7 18.1 18.4
Air Circulation (Indoor/Hi)
ft³/min. 355 385 625 640 650 10 Quiet function allows you to sleep 12
Indoor (H/L/Q-Lo) (dB-A) 36/26/23 - 36/26/23 38/28/25 - 38/28/25 44/32/29 - 44/32/29 45/34/31 - 45/34/31 47/37/34 - 47/37/34 comfortably at night.
Noise Level
Outdoor (H/L) (dB-A) (46) - (47) (47) - (48) (49) - (50) (51) - (52) (52) - (53) 11 Set the 24-hour ON & OFF Timer or
mm 296 (511) 296 (542) 296 (619) 296 (695) 296 (795) 24-hour Dual ON & OFF Timer.
Height
inch 11-21/32 (20-1/8) 11-21/32 (21-11/32) 11-21/32 (24-3/8) 11-21/32 (27-3/8) 11-21/32 (31-5/16)
12 Set the actual time (hour and minute).
mm 870 (650) 870 (780) 1,070 (824) 1,070 (875) 1,070 (875)
Dimensions Width
inch 34-9/32 (25-19/32) 34-9/32 (30-23/32) 42-5/32 (32-15/32) 42-5/32 (34-15/32) 42-5/32 (34-15/32) Wireless
mm
Applicable to PREMIUM Inverter
236 (230) 236 (289) 241 (299) 241 (320) 241 (320)
Depth
inch 9-15/16 (9-1/16) 9-15/16 (11-13/32) 9-1/2 (11-25/32) 9-1/2 (12-5/8) 9-1/2 (12-5/8)
kg 9 (20) 9 (26) 12 (34) 12 (46) 12 (57)
Net Weight DUAL TIMER
lb 20 (44) 20 (57) 26 (75) 26 (101) 26 (126)
mm ø 6.35 ø 6.35 ø 6.35 ø 6.35 ø 6.35
Liquid Side
inch 1/4 1/4 1/4 1/4 1/4
Refrigerant Pipe Diameter
mm ø 9.52 ø 12.70 ø 12.70 ø 15.88 ø 15.88 DUAL TIMER FOR 2 ON AND OFF TIMES PER DAY
Gas Side
inch 3/8 1/2 1/2 5/8 5/8
For convenience, the dual timer repeats everyday until you cancel it.
Chargeless Pipe Length m 7.5 7.5 10 10 10
Maximum Pipe Length m 15 15 20 20 30
Pipe Extension Select ON or OFF Timer
Maximum Elevation Length m 5 5 15 15 20
Additional Refrigerant Gas* g/m 15 15 15 20 30
Power Supply Indoor Indoor Indoor Indoor Outdoor 1 2 Cancel 1 2 Cancel
Caution For CS-S10/S13/S18/S24/S28RKH (Important) Please do not use copper pipes that are less than 0.6mm in thickness.
* When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit. Set the time.
OUTDOOR
CU-S10RKH CU-S13RKH CU-S18RKH CU-S24RKH CU-S28RKH
Confirm.
TIMER
20 21
PRODUCT LINE UP
Wall-Mounted : Deluxe non-Inverter Single-Split Type
MODEL (50Hz) CS-C9RKH CS-C12RKH CS-C18RKH CS-C24RKH CS-C28RKH 4 Activates the nanoe-G function even when
(CU-C9RKH) (CU-C12RKH) (CU-C18RKH) (CU-C24RKH) (CU-C28RKH) the air conditioner is switched off.
2 3
Btu/h 9,040 - 9,210 12,000 - 12,200 18,400 - 18,400 24,000 - 24,000 26,900 - 27,300 5 Press up or down to set the temperature.
Cooling Capacity
kW 2.65 - 2.70 3.52 - 3.57 5.40 - 5.40 7.03 - 7.03 7.90 - 8.00
6 5 4
EER Btu/hW 11.3 - 11.0 10.8 - 10.6 10.5 - 10.0 10.2 - 9.7 9.9 - 9.9 6 Toggles between iAUTO, COOL, and DRY
setting mode.
Voltage V 220 - 240 220 - 240 220 - 240 220 - 240 220 - 240 7 8
Electrical Data Running Current A 3.8 - 3.7 5.2 - 5.2 8.5 - 8.4 11.0 - 11.1 12.6 - 12.0 7 Auto comfort mode detects high activity
levels and switches to comfort operation
Power Input W 800 - 835 1,110 - 1,150 1,750 - 1,850 2,350 - 2,470 2,720 - 2,760 for maximum comfort. 10
9
L/h 1.6 2.1 2.9 4.0 4.7
Moisture Removal 8 Set the airflow.
Pt/h 3.4 4.4 6.1 8.5 9.9
11
m³/min. 9.8 10.8 16.4 18.2 20.2 9 Adjusts the fan speed.
Air Circulation (Indoor/Hi)
ft³/min. 346 381 579 642 713
12
10 Quiet function allows you to sleep
Indoor (H/L) (dB-A) 36/26 - 36/26 39/29 - 29/29 43/37 - 43/37 46/40 - 46/40 49/44 - 49/44 comfortably at night.
Noise Level
Outdoor (H/L) (dB-A) (46) - (47) (48) - (49) (53) - (54) (54) - (55) (55) - (56)
11 Set the 24-hour ON & OFF Timer.
mm 296 (511) 296 (511) 296 (542) 296 (695) 296 (750)
Height
inch 11-21/32 (20-1/8) 11-21/32 (20-1/8) 11-21/32 (21-11/32) 11-21/32 (27-3/8) 11-21/32 (29-17/32)
12 Set the actual time (hour and minute).
mm 870 (650) 870 (650) 1,070 (780) 1,070 (875) 1,070 (875)
Dimensions Width
inch 34-9/32 (25-19/32) 34-9/32 (25-19/32) 42-5/32 (30-23/32) 42-5/32 (34-15/32) 42-5/32 (34-15/32) Wireless
Applicable to Deluxe non-Inverter
mm 236 (230) 236 (230) 241 (289) 241 (320) 241 (345)
Depth
inch 9-5/16 (9-1/16) 9-5/16 (9-1/16) 9-1/2 (11-13/32) 9-1/2 (12-5/8) 9-1/2 (13-19/32)
kg 9 (21) 9 (25) 12 (34) 12 (52) 12 (62)
Net Weight
lb 20 (46) 20 (55) 26 (75) 26 (115) 26 (137)
mm ø 6.35 ø 6.35 ø 6.35 ø 6.35 ø 6.35
Liquid Side
inch 1/4 1/4 1/4 1/4 1/4 TO SET THE TIMER
Refrigerant Pipe Diameter
mm ø 9.52 ø 12.70 ø 12.70 ø 15.88 ø 15.88
Gas Side To turn the unit ON or OFF at a preset time.
inch 3/8 1/2 1/2 5/8 5/8
1 2 3
Chargeless Pipe Length m 7.5 7.5 7.5 7.5 7.5
TIMER
* When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit.
OUTDOOR 2
22 23
PRODUCT LINE UP
Wall-Mounted : Standard non-Inverter Single-Split Type
(Optional)
(Random)
1 Automatic intelligence switches fan
CS-PC18QKH | CS-PC24QKH | CS-PC28QKH Wireless speed for faster cooling.
CS-PC9QKH CS-PC12QKH CS-PC18QKH/ CS-PC28QKH
CS-PC24QKH
Voltage V 220 - 240 220 - 240 220 - 240 220 - 240 220 - 240
Electrical Data Running Current A 4.4 - 4.3 5.5 - 5.6 8.9 - 9.0 12.2 - 12.1 14.0 - 13.1
5 4
Power Input W 845 - 885 1,170 - 1,210 1,920 - 1,980 2,570 - 2,700 2,990 - 3,040 5 Press up or down to set the temperature.
OUTDOOR 2
OFF
TIMER
CU-PC9QKH CU-PC18QKH CU-PC24QKH CU-PC28QKH
CU-PC12QKH Confirm. SET
TIMER OFF
TIMER
24 25
PRODUCT LINE UP AND SPECIFICATIONS
Wall-Mounted : INVERTER Deluxe Multi-Split Type Wall-Mounted : INVERTER Deluxe Multi-Split Type
INDOOR
INVERTER DUAL-SPLIT MODEL DUAL-SPLIT MODEL TRIPLE-SPLIT MODEL
Fan Output W 40 24 24 24 40 40
Models CU-2S18PKZ Indoor Units: Possible Combination Patterns ( Must be within capacity range ) Height mm 290 290 290 290 290 290
Pipe Extension Standard Pipe Length m 7.5 7.5 7.5 7.5 7.5 5.0
• It is possible to have a combination of wall-mounted models (CS-S9, S12PKZW) for the (CU-2S18PKZ) Outdoor Unit Ports. Power Supply Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor
• A minimum of 2 indoor units must be connected. P
OUTDOOR
DUAL-SPLIT MODEL TRIPLE-SPLIT MODEL
Btu/h
17,100 (5,120~20,500) 25,600 (9,550~27,300)
(Min - Max)
Cooling Capacity
kW
5.00 (1.50~6.00) 7.50 (2.80~8.00)
(Min - Max)
Btu/hW 12.2 12.4
EER
W/W 3.60 3.60
COOLING MODELS
Voltage V 240 240
C
Electrical Data Running Current A 6.1 9.4
W
Wireless Power Input 1,400 (250~1,750) 2,060 (520~2,650)
(Min - Max)
25m
(Random) (1 Room) Sound Pressure Level Outdoor (Hi/Lo) (dB-A) 49 49
Fan Output W 40 44
Models CU-3S27MKZ Indoor Units: Possible Combination Patterns ( Must be within capacity range ) Height mm 619 695
* When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit.
26 27
PRODUCT LINE UP
Wall-Mounted : INVERTER Standard Single-Split Type
2 Room 2.8 + 3.2 6.0 2.30 2.70 5.00 1.50 ~ 5.90 1,490 250 ~ 1,710 6.75 1.5 + 1.6
COOLING MODELS
3.2 + 3.2 6.4 2.50 2.50 5.00 1.50 ~ 6.00 1,400 250 ~ 1,750 6.10 1.5 + 1.5
(Optional)
(Random)
Wireless Wired
INVERTER TRIPLE-SPLIT MODEL (CU-3S27MKZ) CS-PS24NKH (Optional) CS-PS9QKH/
CS-PS12QKH
CS-PS18NKH/
CS-PS24NKH
(Optional)
2.8 + 2.8 5.6 2.80 2.80 5.60 1.70 ~ 6.40 1,750 420 ~ 2,600 8.0 1.6 + 1.6 EER Btu/hW 11.5 11.3 11.4 10.8
4.0 + 4.0 8.0 2.70 ~ 7.60 2,870 540 ~ 3.310 Indoor (H/L) (dB-A) 36/26 - 36/26 38/28 - 38/28 44/32 - 44/32 45/36 - 45/36
3.75 3.75 7.50 13.0 2.2 + 2.2
Noise Level
Outdoor (dB-A) (46) - (47) (47) - (48) (49) - (49) (49) - (50)
4.0 + 5.0 9.0 3.33 4.17 7.50 2.80 ~ 7.80 2,600 530 ~ 3,300 11.8 1.9 + 2.4
mm 290 (511) 290 (511) 290 (542) 290 (695)
5.0 + 5.0 10.0 3.75 3.75 7.50 2.90 ~ 8.00 2,440 520 ~ 3,300 11.1 2.2 + 2.2 Height
inch 11-7/16 (20-1/8) 11-7/16 (20-1/8) 11-7/16 (21-11/32) 11-7/16 (27-3/8)
2.8 + 2.8 + 2.8 8.4 2.50 2.50 2.50 7.50 2.40 ~ 7.60 2,740 580 ~ 3,170 12.4 1.5 + 1.5 + 1.5
mm 850 (650) 850 (650) 870 (780) 1,070 (875)
Dimensions Width
2.8 + 2.8 + 3.2 8.8 2.39 2.39 2.72 7.50 2.40 ~ 7.70 2,690 580 ~ 3,170 12.2 1.5 + 1.5 + 1.6 inch 33-15/32 (25-19/32) 33-15/32 (25-19/32) 34-9/32 (30-23/32) 42-5/32 (34-15/32)
2.8 + 2.8 + 4.0 9.6 2.19 2.19 3.12 7.50 2.60 ~ 8.00 2,490 600 ~ 3,260 11.3 1.4 + 1.4 + 1.8 mm 199 (230) 199 (230) 214 (289) 240 (320)
Depth
2.8 + 2.8 + 5.0 10.6 1.98 1.98 3.54 7.50 2.80 ~ 8.00 2,250 600 ~ 2,910 10.2 1.3 + 1.3 + 2.0 inch 7-27/32 (9-1/16) 7-27/32 (9-1/6) 8-7/16 (11-13/32) 9-15/32 (12-5/8)
2.8 + 3.2 + 3.2 9.2 2.28 2.61 2.61 7.50 2.40 ~ 7.70 2,690 580 ~ 3,180 12.2 1.5 + 1.6 + 1.6 kg 8 (20) 8 (23) 9 (31) 12 (44)
Net Weight
lb 18 (44) 18 (51) 20 (68) 26 (97)
2.8 + 3.2 + 4.0 10.0 2.10 2.40 3.00 7.50 2.60 ~ 8.00 2,450 600 ~ 3,200 11.1 1.4 + 1.5 + 1.7
mm ø 6.35 ø 6.35 ø 6.35 ø 6.35
2.8 + 3.2 + 5.0 11.0 1.91 2.18 3.41 7.50 2.80 ~ 8.00 2,250 600 ~ 2,910 10.2 1.2 + 1.4 + 2.0 Liquid Side
inch 1/4 1/4 1/4 1/4
2.8 + 4.0 + 4.0 10.8 1.94 2.78 2.78 7.50 2.70 ~ 8.00 2,290 600 ~ 3,020 10.4 1.3 + 1.6 + 1.6 Refrigerant Pipe Diameter
mm ø 9.52 ø 12.70 ø 12.70 ø 15.88
Gas Side
2.8 + 4.0 + 5.0 11.8 1.78 2.54 3.18 7.50 2.80 ~ 8.00 2,170 580 ~ 2,760 9.8 1.1 + 1.6 + 1.8 inch 3/8 1/2 1/2 5/8
3 Room
2.8 + 5.0 + 5.0 12.8 1.64 2.93 2.93 7.50 2.80 ~ 8.00 2,070 520 ~ 2,650 9.4 1.0 + 1.7 + 1.7 Chargeless Pipe Length m 7.5 7.5 10 10
3.2 + 3.2 + 3.2 9.6 2.50 2.50 2.50 7.50 2.40 ~ 7.70 2,650 590 ~ 3,190 12.0 1.5 + 1.5 + 1.5 Maximum Pipe Length m 15 15 20 20
Pipe Extension
10.4 2.31 2.88 7.50 2.60 ~ 8.00 600 ~ 3,210 11.1 1.5 + 1.5 + 1.7 Maximum Elevation Length m 5 5 15 15
3.2 + 3.2 + 4.0 2.31 2,450
Additional Refrigerant Gas* g/m 15 15 15 20
3.2 + 3.2 + 5.0 11.4 2.11 2.11 3.28 7.50 2.80 ~ 8.00 2,250 600 ~ 2,920 10.2 1.4 + 1.4 + 1.9
Power Supply Indoor Indoor Indoor Indoor
3.2 + 4.0 + 4.0 11.2 2.14 2.68 2.68 7.50 2.80 ~ 8.00 2,290 600 ~ 2,960 10.4 1.4 + 1.6 + 1.6
Caution For CS-PS9/PS12QKH and PS18/PS24NKH (Important) Please do not use copper pipes that are less than 0.6mm in thickness.
3.2 + 4.0 + 5.0 12.2 1.97 2.46 3.07 7.50 2.80 ~ 8.00 2,170 580 ~ 2,760 9.8 1.3 + 1.5 + 1.7
* When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit.
3.2 + 5.0 + 5.0 13.2 1.82 2.84 2.84 7.50 2.80 ~ 8.00 2,060 520 ~ 2,650 9.4 1.2 + 1.7 + 1.7
4.0 + 4.0 + 4.0 12.0 2.50 2.50 2.50 7.50 2.80 ~ 8.00 2,170 590 ~ 2,820 9.8 1.5 + 1.5 + 1.5
4.0 + 4.0 + 5.0 13.0 2.31 2.31 2.88 7.50 2.80 ~ 8.00 2,070 540 ~ 2,650 9.4 1.5 + 1.5 + 1.7
OUTDOOR
• Specification based on JIS C 9612 standard. CU-PS9QKH CU-PS18NKH CU-PS24NKH
• A minimum of 2 indoor units must be connected. CU-PS12QKH
• Switchable between 8.5amp or 11amp.
28 29
PRODUCT LINE UP AND SPECIFICATIONS
Window Type
DELUXE MODEL
COOLING MODELS
CW-XC99JH CW-C99JH CW-C129VH CW-C189EH
CW-C249EH
(Random)
COMFORT
Wireless Touch Control Panel
Powerful Mode
CW-XC99JH
Air Swing
STANDARD MODEL
System
Removable, Washable
Intake Grille
Ventilation Control
CONVENIENCE
12-Hour ON & OFF
Setting Timer
Slide-Out Chassis
( ): Outdoor Unit
*1 Numbers (to the right of logo marks) indicate number of available speeds
*2 "S" indicates Super High speed only during Powerful Mode
Model [50Hz] CW-XC99JH CW-C99JH CW-C129VH CW-C189EH CS-C249EH
Btu/h 9,000 - 9,100 9,000 - 9,100 12,100 - 12,300 18,200 - 18,400 23,700 - 24,200
Cooling Capacity
kW 2.64 - 2.67 2.64 - 2.67 3.55 - 3.60 5.34 - 5.40 6.95 - 7.10
EER Btu/hW 9.6 - 9.3 9.6 - 9.3 9.6 - 9.1 9.0 - 8.7 8.4 - 8.1
Voltage V 220 - 240 220 - 240 220 - 240 220 - 240 220 - 240
Electrical Data
Running Current A 4.4 - 4.3 4.4 - 4.3 6.0 - 6.2 9.7 - 9.9 13.7 - 13.9
Power Input W 935 - 975 935 - 975 1,260 - 1,350 2,020 - 2,120 2,810 - 2,980
L/h 1.6 1.6 2.1 2.9 4.1
Moisture Removal
Pt/h 3.4 3.4 4.4 6.1 8.7
m³/min. 6.7 - 7.2 6.8 - 7.3 9.2 - 9.8 13.3 - 14.0 16.4 - 17.4
Air Circulation (Indoor/Hi)
ft³/min. 240 - 250 240 - 260 320 - 350 470 - 490 580 - 610
mm 346 346 375 428 428
Height
inch 13-5/8 13-5/8 14-25/32 16-7/8 16-7/8
mm 450 450 560 660 660
Dimensions Width
inch 17-23/32 17-23/32 22-1/16 26 26
mm 590 590 613 707 776
Depth
inch 23-7/32 23-7/32 24-1/8 27-27/32 30-9/32
kg 29 29 38 67 72
Net Weight
lb 64 64 84 148 159
30 31
PRODUCT LINE UP
Floor or Ceiling and Floor Standing Type
FEATURES EXPLANATION
COOLING MODELS
COMFORT
iAUTO-X iAUTO AIRFLOW DIRECTION CONTROL
Come home to fast cooling. Then enjoy continuous Automatic Intelligence switches fan speed for faster (UP & DOWN)
comfort with Shower Cooling which avoids direct cooling. cooling with just one touch of a button.
COOLING MODELS AUTOCOMFORT SOFT DRY OPERATION MODE AUTOMATIC OPERATION MODE
Detects high activity levels and adjusts cooling power Starts with cooling to dehumidify, then provides
to improve comfort. continuous breeze at a low frequency to keep a room
dry without much change to the temperature.
(Optional)
(Random) CS-C18FFH-E
INVERTER CONTROL PERSONAL AIRFLOW CREATION
Varies the rotation speed of the compressor for Vertical and horizontal airflow patterns can be
higher energy savings. combined as desired to achieve optimum comfort, with
CS-C28FFH-E/ CS-C45FFH-E CS-C18FFH-E/ (Optional)
CS-C28FFH8-E CS-C28FFH-E/ CS-C18FFH-E/ operation possible by remote even from a distance.
(Optional) Wireless Wireless
CS-C28FFH8-E CS-C28FFH-E/
CS-C28FFH8-E
(Optional)
CLEANER AIR
CS-C18FFH-E | CS-C28FFH-E | CS-C28FFH8-E CS-C45FFH-E CS-C18FFH-E/
CS-C28FFH-E/
nanoe- G
CS-C28FFH8-E ODOUR-REMOVING FUNCTION REMOVABLE, WASHABLE PANEL
nanoe-G works effectively on airborne particles
SPECIFICATIONS including PM2.5, adhesive and in-filter With this function, there's no unpleasant odor when
micro-organisms such as bacteria, viruses and mould the unit starts up. That's because the fan remains off
momentarily, while the source of the odour inside the
( ): Outdoor Unit ensuring a cleaner living environment.
air conditioner is suppressed. CATECHIN AIR PURIFYING FILTER
ANTI-BACTERIAL FILTER
The unit must be in cool or dry mode and the fan speed
The Anti-Bacterial Filter combines three effects in
MODEL (50Hz) CS-C12CTH CS-C18CTH CS-C24CTH CS-C18FFH-E CS-C28FFH-E CS-C28FFH8-E CS-C45FFH-E must be set to automatic.
SOLAR REFRESHING DEODORISING FILTER
(CU-C12CTH) (CU-C18CTH) (CU-C24CTH) (CU-C18FFH-E) (CU-C28FFH-E) (CU-C28FFH8-E) (CU-C45FFH-E) one: anti-allergen, anti-virus and anti-bacteria
protection to provide clean air.
Btu/h 12,000 - 12,200 18,400 24,000 17,400 - 17,600 24,600 - 25,000 24,600 41,000 - 42,700 CONVENIENCE
Cooling Capacity
kW 3.52 - 3.57 5.40 7.04 5.10 - 5.15 7.20 - 7.30 7.20 12.00 - 12.50
24-HOUR DUAL ON & OFF 24-HOUR ON & OFF LCD WIRELESS REMOTE CONTROL
EER Btu/hW 11.4 - 10.9 10.5 - 10.2 9.8 - 9.3 9.2 - 9.0 9.5 - 9.4 9.8 8.7 - 8.9 REAL SETTING TIMER REAL SETTING TIMER
ø This feature enables you to preset two different sets of The exact operating time (hour and minute) of the air
Phase 1 1 1 1 1 3 3
start/stop operation timer (hour and minute) within a conditioner can be set in advance. From here on, the
24-hour time frame. unit will operate in accordance to these preset hours
WIRED REMOTE CONTROL
Voltage V 220 - 240 220 - 240 220 - 240 220 - 240 220 - 240 380 380 - 415 every day until the system is reset.
Electrical Data Running Current A 5.1 - 4.9 8.4 - 8.1 12.0 - 12.3 8.7 - 8.8 11.9 - 12.0 4.5 8.4
RELIABILITY
Power Input W 1,050 - 1,120 1,760 - 1,810 2,450 - 2,570 1,900 - 1,950 2,600 - 2,650 2,500 4,710 - 4,800
AUTO RESTART BLUE FIN CONDENSER TOP-PANEL MAINTENANCE ACCESS
L/h 2.1 2.9 4.0 2.8 4.2 4.2 7.5
Moisture Removal (Memory)
Pt/h 4.4 6.1 8.5 5.9 8.9 8.9 15.8 SELF-DIAGNOSTIC FUNCTION
RANDOM AUTO RESTART LONG PIPING Should a malfunction occur, the unit diagnoses the
m³/min. 10.6 15.0 15.2 14.5 - 15.5 15.0 - 16.2 15.0 27.0 problem and shows the corresponding alphanumeric
Air Circulation (Indoor/Hi) (Random) code. This allows for quicker servicing.
ft³/min. 370 530 540 512 - 547 530 - 572 530 953
Indoor (H/L) (dB-A) 41/35 - 41/35 50/44 - 50/44 51/45 - 51/45 46/40 - 47/41 48/42 - 49/43 48/43 53/47
Noise Level
Outdoor (dB-A) (48) - (49) (54) - (56) (59) - (61) (53) - (54) (53) - (54) (53) (57) OPTIONAL ACCESSORIES
mm 540 (540) 540 (685) 540 (685) 1,680 (540) 1,680 (795) 1,680 (795) 1,880 (1,175)
Height
inch 21-9/32 (21-9/32) 21-9/32 (26-31/32) 21-9/32 (26-31/32) 66-1/8 (21-5/16) 66-1/8 (31-19/64) 66-1/8 (31-19/64) 74 (64-17/64)
REMOTE CONTROL FILTERS replacement: every 3 years
mm 1,028 (780) 1,028 (800) 1,028 (800) 500 (780) 500 (900) 500 (900) 600 (900)
Dimensions Width
inch 40-1/2 (30-23/32) 40-1/2 (31-1/2) 40-1/2 (31-1/2) 19-11/16 (30-23/32) 19-11/16 (35-7/16) 19-11/16 (35-7/16) 23-5/8 (35-7/16) Wired Remote Control Anti-Bacterial Filter Catechin Air Solar Refreshing SUPER Alleru-Buster Filter SUPER Alleru-Buster
(Optional) Purifying Filter Deodorising Filter for Window Type (with Filter for Window Type
mm 200 (289) 200 (300) 200 (300) 298 (289) 298 (320) 298 (320) 350 (320) frame) (without frame)
Depth
inch 7-7/8 (11-13/32) 7-7/8 (11-13/36) 7-7/8 (11-13/36) 11-23/32 (11-3/8) 11-23/32 (12-19/32) 11-23/32 (12-19/32) 13-25/32 (12-19/32)
kg 18 (38) 18 (55) 20 (60) 34 (40) 35 (55) 35 (55) 52 (88)
Net Weight
lb 40 (84) 40 (121) 44 (132) 75 (88) 77 (121) 77 (121) 115 (194)
mm ø 6.35 ø 6.35 ø 6.35 ø 6.35 ø 9.52 ø 9.52 ø 9.52 CZ-RD514C CZ-SA22P CZ-SF70P CZ-SFD70P
Liquid Side CZ-SAW18P CZ-SA18P
inch 1/4 1/4 1/4 1/4 3/8 3/8 3/8
Refrigerant Pipe Diameter
mm ø 12.70 ø 12.70 ø 15.88 ø 12.70 ø 15.88 ø 15.88 ø 19.05
CS-S10RKH, CS-S13RKH, CS-S18RKH, CS-PC9QKH, CS-PC12QKH, CS-PC18QKH, CS-C18FFH-E, CS-C28FFH-E, CS-C28FFH8-E
Gas Side CW-XC99JH, CW-C99JH, CW-C129VH,
inch 1/2 1/2 5/8 1/2 5/8 5/8 3/4 CS-S24RKH, CS-S28RKH, CS-PS9QKH, CS-PC24QKH, CS-PC28QKH, CS-PS9QKH, CW-C189EH, CW-C249EH
Chargeless Pipe Length m 7.5 7.5 7.5 7.0 7.0 7.0 15.0 CS-PS12QKH, CS-PS18NKH,CS-PS24NKH CS-PS12QKH, CS-PS18NKH, CS-PS24NKH
Maximum Pipe Length m 15 25 25 10 15 15 30
Pipe Extension
Maximum Elevation Length m
20
20
20
20
30
7
25
10
30
10
30
20
50
The System of Model Numbers for Split Models
1 Model Type
Power Supply Indoor Indoor Indoor Indoor Indoor Outdoor Outdoor CS : Split Type (Indoor Unit) CS S 9 P K Z W
CU : Split Type (Outdoor Unit) 1 3 4 5 2
Rating Conditions
* When pipes are not extended from the chargeless pipe length, the required amount of refrigerant is already in the unit. CW : Window Type
CZ : Accessories Cooling
CU 2 S 18 P K Z
2 Connection Configuration Inside air temperature 27°C DB (19°C WB)
1 2 3 4 5
<Indoor Unit>
Outside air temperature 35°C DB (24°C WB)
OUTDOOR CU-C12CTH CU-C18CTH/
CU-C24CTH
CU-C18FFH-E CU-C28FFH-E/
CU-C28FFH8-E
CU-C45FFH-E
W : Multi Split
<Outdoor Unit>
n : (n) Rooms Multi
4 Capacity
Value = Capacity (Btu/h) x 1/1000, e.g. 9,000 Btu/h x 1/1000 = 9
3 Function 5 Type
S : Cooling Only (Inverter Deluxe) K : Wall-Mounted Type
C : Cooling Only T : Floor or Ceiling Dual Mountable Type
PS : Cooling Only (Standard) F : Floor Standing Type
32 33
FEATURES COMPARISON
COMFORT COMFORT
iAUTO-X iAUTO-X
ECONAVI ECONAVI
AUTOCOMFORT AUTOCOMFORT
iAUTO iAUTO
Odour-Removing Odour-Removing
Function Function
CONVENIENCE CONVENIENCE
24-Hour Dual ON & OFF 24-Hour Dual ON & OFF
Real Setting Timer Real Setting Timer
Wired Remote Control (Optional) (Optional) Wired Remote Control (Optional) (Optional)
RELIABILITY RELIABILITY
Long Piping (Numbers indicate 20m (S18/S24) 10m (C9) 25m (C18/C24) 10m (PC9) 25m (PC18/PC24) Long Piping (Numbers indicate 15m (C12) 10m (C18)
the maximum pipe length) 15m the maximum pipe length) ** Refer Page 27 ** Refer page 27 15m 20m 30m
30m (S28) 15m (C12) 30m (C28) 15m (PC12) 30m (PC28) 25m (C18/C24) 15m (C28)
34 35
iAUTO-X TECHNICAL EXPLANATION
OUTER FLAP
*Remark:
Super High fan speed applicable for PREMIUM Inverter with iAUTO-X
36 37
iAUTO-X TECHNICAL EXPLANATION
HOW DOES
FAST COOLING
WORK?
29ºC
Quick
AUTOMATIC FAN SPEED 25ºC
PREMIUM Inverter with iAUTO-X
Standard non-Inverter model with
high fan
iAUTO-X will automatically switch fan speed to high fan
speed and super high fan speed depending on the temperature
difference between the room and the set temperature. Time
LOW SPEED
PREMIUM INVERTER WITH iAUTO-X STANDARD NON-INVERTER MODEL WITH HIGH FAN
MEDIUM SPEED * Comparison of 1.5HP PREMIUM Inverter with iAUTO-X mode and
Standard non-Inverter model with cooling mode
35 %*
PREMIUM Inverter: iAUTO-X Mode
iAUTO-X Mode, Outside Temperature: 35˚C /24˚C
Remote setting temperature: 25˚C with Fan Speed: Auto
HIGH FAN SPEED Horizontal Airflow direction: Auto, Vertical Airflow direction: Straight
SUPER HIGH FAN SPEED The time to reach the setting temperature was measured.
At Panasonic Amenity Room (size: 16.6m²)
The effect differs according to conditions in installation and usage.
Remark:
Applicable for PREMIUM Inverter with iAUTO-X warmer cooler
38 39
iAUTO-X TECHNICAL EXPLANATION
HOW DOES
SHOWER COOLING
WORK?
If direct airflow continues, you may start to feel too cold. After reaching the set temperature, the twin flaps direct air towards the
ceiling to create the Shower Cooling effect. Then, Human Activity Sensor
detects the level of activity to keep you comfortable.
40 41
NEW REMOTE CONTROL
BIGGER,
BIGGER
The larger remote control fits ergonomically in your palm and makes it easier to read and activate any button on the remote control.
BETTER,
PKH (2014) RKH (2015)
EASIER.
47mm 23.5mm
160mm
134mm
BETTER EASIER
A larger LCD screen allows The extra large buttons are
for better visibility of icons. easy to use and see. This
makes it easier to push any
button on the remote control.
40mm
22.5mm
30mm
23mm 48.3mm
30.5mm
HOW DOES
HUMAN
ACTIVITY DETECTION HOW DOES ECONAVI HUMAN ACTIVITY WORK?
ECONAVI detects changes in activity levels and reduces the PRESENT ABSENT
waste of cooling with unnecessary power. Enter Room Low High Normal Exit Room Out
ACTIVITY
Low Activity
Detection 1 2 3 4 5
Human
Presence/
Absence
Energy Waste
Wasted! Reduced! Legend:
Set Temperature Cooling Power
DETECTION
+2°C Remark: Set temperature on remote control display
+2°C remains unchanged.
Set
DETECT ADJUSTED Temperature 20 mins +1°C 20 mins
Level of activity is decreased. Reduces cooling power by an 1 Hour
Detects low activity. amount equivalent to increasing -1°C
the set temperature by 1 degree
Celsius. Fan Speed Set Speed Max Medium Fan
WORK?
Cooling
ABSENCE DETECTION
ECONAVI detects human absence in the room and reduces
the waste of cooling an empty room.
HUMAN ACTIVITY SENSOR
ECONAVI monitors activity and room conditions to detect
where energy is normally wasted, then adjusts cooling ECONAVI DUAL SENSOR
power accordingly. With Intelligent Eco Sensors, it adjusts
to changes in human movement, activity levels, absence Energy
Wasted!
Waste
Reduced! ECONAVI dual sensor consists of High
and sunlight intensity. With a touch of a button, 5 energy Precision Sensor and Fresnel Lens.
saving features get activated: These sensors can detect wasted
DETECT ADJUSTED
energy and automatically select an
No one is in the room. Gradually reduces cooling optimum energy-saving operation
Detects absence. power by an amount equivalent to
increasing the set temperature based on 5 factors – Activity Detection,
by 2 degrees Celsius.
Absence Detection, Area Search,
Temperature Wave and Sunlight
Detection.
AREA SEARCH
ECONAVI detects changes in human movements and reduces
High Precision Sensor
the waste of cooling the unoccupied area of the room.
This high precision sensor analyses
and judges the detected infrared DETECTING HUMAN PRESENCE
ray reaction.
Difference in temperatures Difference in temperatures Difference in temperatures
Waste
Energy Reduced!
Wasted!
Movement Movement Movement
Fresnel Lens
This optimal design directs the infrared When there is no movement for over 20min.
DETECT ADJUSTED rays from the entire room to the sensor.
Only one person in the room. Reduces cooling the unoccupied
Detects wasted cooling area. area of the room.
TEMPERATURE WAVE
ECONAVI with Temperature Wave
incorporates a unique pattern of
WHEN ECONAVI DETECTS LOW ACTIVITY
Offset Thermal
DETERMINING THE LEVEL OF HUMAN ACTIVITY
Physiological Response
Temperature Shifting Control to +1°C
realise even more energy savings Average Room Temperature (Degree Celcius)
Scale Frequency Speed of Movement
without sacrificing comfort. Set
Rhythmic Moderate temperature increase
Result : More Energy Saving
Temperature
A highly precise conclusion is reached through a complex algorithm
Thermal Sensation Votes (Mean Votes)
Time (min) 0 10 20 30 40 50 60 70 80 90 100 110 120 140
Rhythmic -0.1
Result : Maintain within the comfortable range *
Legend: Set Temperature Cooling Power High Normal
Remark: Set temperature on remote control display remains unchanged. Concludes Level of Activity High or Normal
Temperature Wave is only applicable to Inverter deluxe cooling models.
Temperature Wave works either in ECONAVI or Autocomfort mode during low activity.
44 45
ECONAVI TECHNICAL EXPLANATION
HOW DOES
SUNLIGHT
HIGH-PRECISION SENSING COVERAGE CAPABILITIES
Human Activity Sensor covers a wider area due to its
improved area detection function.
DETECTION
All objects emit infrared rays, which although invisible, can
be detected as heat by ECONAVI’s Human Activity Sensor if THE ENTIRE ROOM IS DIVIDED INTO 3 DETECTION AREAS
it is within the detection zone. When an object moves
within its detection zone, ECONAVI compares the object’s HORIZONTAL SENSING AREA VERTICAL SENSING AREA
temperature with the room temperature to determine if it
WORK?
is human, and level of activity based on its movement.
7m
2m
7m
120°
ECONAVI detects changes in sunlight intensity in the
Remark: Applicable for dual sensor. room and judges whether it is sunny or cloudy/night. It
reduces the waste of cooling under less sunlight conditions.
DIFFERENTIATING OBJECTS
OBJECTS DIFFERENCE IN TEMPERATURE + MOVEMENT DETECTION When weather changes from
Eletrical Products
sunny to cloudy/night, ECONAVI
Concludes it is not human detects less sunlight intensity
Energy
Wasted!
Waste
Reduced! and determines less cooling
Set
Temperature
Set
Temperature
Set
Temperature power is required. If cooling
Small Insects Concludes it is not human 23°C 23°C 24°C power remains the same, energy
Both changes may be detected, but they are
too small to have any effect on the sensor.
SUNNY DETECT REDUCE WASTE will be wasted. ECONAVI detects
ECONAVI is switched on when it is
SUNNY.
ECONAVI detects less cooling
power is required.
Set temperature remains
unchanged. ECONAVI reduces this waste and reduces cooling
A Rolling Ball
cooling power by an amount
equivalent to increasing the set power by an amount equivalent
Concludes it is not human temperature by 1 degree Celsius.
to increasing the set temperature
by 1 degree Celsius.
Concludes it is not human*
Pets From the difference in temperatures and the
nature of the object’s movement, ECONAVI
can determine if it’s human*.
*The sensor may deem pets as humans, unless it moves within the
detection zone at speeds that are not humanly possible. HOW DOES ECONAVI SUNLIGHT SENSOR WORK?
SUNNY WHEN ECONAVI IS SWITCHED ON
DETECTION AREA DETECTION AREA DETECTION AREA DETECTION AREA CLOUDY / NIGHT WHEN ECONAVI IS SWITCHED ON
+2°C
1 Hour Legend:
Set Set Temperature Cooling Power
Temperature
30 mins 20 mins Remark: Set temperature on remote control display
-1°C
remains unchanged.
1 2 3 1 2 3 1 2 3 1 2 3
Judgement time
Remark: When detecting any change in movements, there will be a time delay between the LED indicator lighting up and a change of airflow direction. Remark: When ECONAVI is switched on during cloudy/night, the temperature will be maintained at the set temperature.
This is to avoid over-sensitive louver movements which will not contribute to energy savings. Only when the sensor detects a change from sunny to cloudy/night, it will adjust cooling power accordingly.
46 47
INVERTER TECHNICAL EXPLANATION
TO ITS
energy saving performance while ensuring you stay
comfortable at all times. A conventional non-INVERTER ECONAVI detects changes in activity levels and reduces the
ABILITY IS
air conditioner can only operate at a constant speed waste of cooling with unnecessary power.
which is too powerful to maintain the set temperature.
Thus, it switches the compressor on and off repeatedly. NON-INVERTER
This results in wider temperature fluctuations leading
to wasteful consumption of energy. The Panasonic Room Big temperature
INVERTER air conditioner varies the rotation speed of temperature fluctuations
FLEXIBILITY.
the compressor, providing a precise method of maintaining
the set temperature. Set
temperature
Output power
ON OFF ON OFF ON
have the flexibility to vary the rotation Remark: Energy is wasted by switching the
speed of the compressor. Legend: Output Power Temperature compressor ON and OFF to maintain
the set temperature.
INVERTER
Set temperature
Output power
ON
Time
CONSTANT COMFORT
Precise temperature control with a wide power output range enables an
INVERTER air conditioner to meet different room occupancy levels – thus
ensuring constant comfort.
When required, the unit operates When not required, the unit operates at
at full power. low power to save energy.
Graph shows the 1.5HP Inverter model’s wide power output range during cooling.
48 49
nanoe-G TECHNICAL EXPLANATION
WHAT IS
PM2.5?
PM2.5 REMOVAL EFFICIENCY BASED ON TIME
SERIAL MEASUREMENT OF PM2.5 CONCENTRATION
Size
Time Elapsed (min.)
POLLEN (μm)
10µm-100µm
Large
10µm
BACTERIA REMOVES *¹ PM2.5 Removal was certified by FCG Research Institute, Inc
99
1µm-10µm • Test Report no. : 25034
%*1
PM2.5 : Cigarette Smoke (as PM2.5)
PM2.5 is found in PM2.5 All results are based on specific testing conditions.
All tests are not demonstrated under actual usage situation.
∙ Industrial Smoke
AIRBORNE
VIRUS
∙ Exhaust Gas
0.001µm-0.1µm ∙ Haze *² Airborne Removal was certified by Kitasato Research Center for Environmental Science
∙ Cigarette Smoke REMOVES • KRCES-Bio. Test Report no. : 23_0182
Small
99
Bacteria : Staphylococcus aureus (NBRC 12732)
%*2
• KRCES-Env. Test Report no. : 22_0008
Virus : Escherichia coli phage (øX-174 ATCC 13706-B1)
: Influenza (H1N1) 2009 Virus
• KRCES-Env. Test Report no. : 23_0140
SOURCES OF PM2.5
BACTERIA Mould : Penicillium pinophilum (NBRC 6345)
VIRUSES All results are based on specific testing conditions.
and MOULD All tests are not demonstrated under actual usage situation.
PM2.5 can be found suspended in the air, including dust, dirt, smoke and liquid droplets.
These fine particles come from man-made sources such as the combustion of fossil
fuels, open burning and industrial processes as well as natural ones, which include sea
sprays and dust carried by strong winds.
50 51
nanoe-G TECHNICAL EXPLANATION
5
The effect after 100 minutes in a 40 m³ test space [about the size of a 10 tatami mat room], not the effect in a space where Decrease in odour intensity by one level after 2 hours of operation.
actually used.
In a large space of 40 m³
4.17
Removal effect has been evaluated. “Performance evaluation of a novel ionizer for air purification applications”. Dr. S. Rudnick et 4
al. Harvard School of Public Health, Environmental Health Nanoscience Lab. Test Subject: Adhesive smell of tobacco smoke
3.25
1
nanoe-G Test Chamber: 20m³ 1 Level Down
Odour Intensity
A study of the removal effect of airborne bacteria by using an air-conditioner incorporating Measurement Method: Six-level odour intensity indication method 3
nanoe-G was carried out in a large space, and the results were presented at
C/Co (Normalized spore concentration)
TARGET SUBSTANCE NAME EFFECTIVENESS TESTING TEST REPORT NO METHOD RESULT TARGET SUBSTANCE NAME EFFECTIVENESS TESTING TEST REPORT NO METHOD RESULT
SUBSTANCE INSTITUTE SUBSTANCE INSTITUTE
The AC with nanoe-G was
The AC with nanoe-G was operated in a test room (23m³) and 99% removal from the
Cigarette smoke FCG Research Test Report
Cigarette Smoke
FCG Research Test Report
operated in a test room (23m³) and 99% removal from the PM2.5 (as PM2.5)
99%
Institute, Inc No. 25034 the concetration of PM2.5 was air after 202 minutes
PM2.5 (as PM2.5) 99% the concentration of PM2.5 was air after 202 minutes of measured by PM2.5 Digital Dust of operation.
Institute, Inc No. 25034 operation.
measured by PM2.5 Digital Dust Indicator.
Indicator.
99% inactivation after
The AC with nanoe-G was
Japan Food Test Report 24 hour operation of
Staphylococcus aureus operated in a test space (10m³)
Bacteria (NBRC 12732)
99% Research No. nanoe-G. (compared to
and viable cells were counted by
Kitasato The AC with nanoe-G was Laboratories 11047933001-02 the original condition/
99% removal from the pour plate method.
Research KRCES-Bio. operated in a test room (25m³) and ventilation mode)
Staphylococcus aureus
Bacteria (NBRC 12732)
99% Center for Test Report aerosol was collected and air after 150 minutes of
Environmental No. 23_0182 bacterial count was calculated. operation. nanoe-G was operated in a test 99% inactivation after
Japan Food Test Report
ADHESIVE
Science Bacteriophage box (90 Litre) and phage infectivity 120 minutes operation
Virus (Phi X 174 NBRC 103405)
99% Research No.
of nanoe-G. (compared
Laboratories 11073649001-02 titer was determined by plaque
technique. to non-operation)
Kitasato The AC with nanoe-G was
Research KRCES-Env. operated in a test room (25m³) and 99% removal from the
99% Center for Test Report airborne phages were collected air after 120 minutes of Cladosporium Inhibit Japan Food Test Report nanoe-G was operated in a test The growth of the
Environmental No. 22_0008 and phage count of the collected operation. Mould cladosporioides Mould Research No. box (1m³) and colonies on the plate subject was inhibited.
Science air was calculated. (NBRC 6348) Growth Laboratories 11047937001-02 were counted. (>85% after 7 days)
Research KRCES-Env. chamber (200 Litre) and the 99% removal from the
Decrease by the deodorisation effect on a piece intensity by one level
99% Center for Test Report phages were collected and phage air after 5 minutes of OMI ODOR-AIR Test Report
Odour Smell of tobacco smoke
one level SERVICE Co.Ltd. No. 13-1204 of cloth impregnated with odour after 120 minutes of
Environmental No. 22_0008 count of the collected air was operation.
components of cigarette smoke operation.
Science calculated.
was evaluated using six-level
odour intensity indication method.
99
*³ Adhesive Deactivation was certified by Japan Food Research Laboratories
%*3
Kitasato In view of health hazard associated with spatial distribution of • Test Report number : 11047933001-02
Research KRCES-Env. Influenza (H1N1) 2009 virus, nanoe-G removal effectiveness Bacteria : Staphylococcus aureus (NBRC 12732)
Influenza (H1N1) 2009 Test Report cannot be tested in large test room (25m³).
99% Center for
ADHESIVE
virus No. 22_0008 When tested in 200 Litre chamber, nanoe-G was able to • Test Report number : 11073649001-02
Environmental Virus : Bacteriophage (Phi X 174 NBRC 103405)
Science decrease Influenza (H1N1) 2009 virus (99%) when it was operated
for 5 minutes. Additionally when tested in larger test room (25m³), BACTERIA • Test Report number : 11047937001-02
nanoe-G can remove 99.5% of Coli phage virus when operated and VIRUSES Mould : Cladosporium cladosporioides (NBRC 6348)
for 120 minutes. All results are based on specific testing conditions.
It was validated that evaluation on the influenza virus could All tests are not demonstrated under actual usage situation.
be speculated from the results on the phage according to the test INHIBITS MOULD GROWTH
results in a 200 Litre test chamber. It appeared that the
air-conditioners in a larger test room (25m³) would be able to
remove the influenza virus as effectively as the phage.
Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
52 53
nanoe-G TECHNICAL EXPLANATION
HOW DOES
IN-FILTER
IN-FILTER DEACTIVATION
TARGET SUBSTANCE NAME EFFECTIVENESS TESTING TEST REPORT NO METHOD RESULT
SUBSTANCE INSTITUTE
DEACTIVATION
The test piece impregnated with 99% of deactivation after
Staphylococcus aureus was placed 2-hour nanoe-G operation.
on the filter of the Air Conditioner
Staphylococcus aureus 99% Japan Food Test Report indoor unit, and then nanoe-G was
Bacteria operated. After the test piece was
(NBRC 12732) Research No. 12037932001
Laboratories collected, viable cells were counted.
WORK?
* test substance was placed on the 4
locations of the filter; upper/lower
right and upper/lower left.
N-FILTER DEACTIVATION
The test piece impregnated with 99% of deactivation after
Escherichia coli phage was placed on 2-hour nanoe-G operation.
the filter of the Air Conditioner indoor
unit, and then nanoe-G was operated.
Escherichia coli phage 99% Japan Food Test Report After the test piece was collected,
(øX-174 ATCC 13706-B1) Research No. 12014705001 phage infectivity titer was determined.
Laboratories * test substance was placed on the 4
locations of the filter; upper/lower
right and upper/lower left.
Virus
Remark: Remark:
Main power must be switched on for the entire The 30-minute fan operation is only applicable when
duration. the unit has been operated in COOL /DRY mode.
Remark: All results are based on specific testing conditions. All tests are not demonstrated under actual usage situation.
Fan Operation : On
Flap : Flaps slightly open
nanoe-G LED : On DEACTIVATES *4 In-Filter Deactivation was certified by Japan Food Research Laboratories
99 %*4
• Test Report number : 12037932001
Bacteria : Staphylococcus aureus (NBRC 12732)
• Test Report number : 12014705001
Virus : Escherichia coli phage (φΧ-174 ATCC 13706-B1)
BACTERIA
IN-FILTER DEACTIVATION
All results are based on specific testing conditions.
All tests are not demonstrated under actual usage situation.
and VIRUSES
DEACTIVATES
AVERAGE In-Filter Deactivation was certified by Kitasato Research Center for Environmental Science
9O %INFLUENZA
• Test Report number : KRCES-Virus Test Report No. 24_0013
Virus : Influenza (H1N1) 2009 Virus
3. nanoe-G OPERATION 4. DEACTIVATION
SERIAL MEASUREMENT EFFECT
OF PM2.5 CONCENTRATION All results are based on specific testing conditions.
All tests are not demonstrated under actual usage situation.
(H1N1)
nanoe-G deactivates bacteria and viruses 2009 VIRUS
Natural Ion Wind spreads nanoe-G particles
that are released from the nanoe-G generator. that are trapped in the filter within 2 hours.
Remark:
Depending on the Air Conditioner’s accumulated operation time, nanoe-G In-Filter Deactivation may
be activated only once a day.
54 55
iAUTO TECHNICAL EXPLANATION
INTELLIGENCE FOR
rectangle (grey)
COOLER
Conventional rectangle drive produces distortions which
results in power efficiency loss.
At start up, iAUTO will run at super high fan speed to cool the
room faster, 15% faster cooling for cooler comfort.
ADVANTAGES OF SINE WAVE
COMFORT.
MOTOR EFFICIENCY DATA (EX. INDOOR UNIT)
75
Efficiency (%)
Reduced current distortion enables fan motor to start 70
Once switched on, iAUTO constantly monitors the running at super high fan speed. This helps to reduce 60
300 500 700 900 1100 1300 1500
difference between the room and the set temperature. power consumption. Speed (r/min)
29ºC Sine Wave regulates power voltage that is identical to power With less distortion, motor loads runs smoother with low
Quick supplied. This ensures consistent performance and stable vibrations. This helps to reduce electrical noise providing
25ºC
operation. quieter operation.
Super High
High
Medium
QUALITY CONTROL THROUGH SIMULATED LABORATORY TEST
Fan Speed
Time
Panasonic carried out testing at our own Environmental Testing Room which simulates a standard living room condition. This
makes it possible to ensure air conditioner operates at optimum performance level under varying conditions.
15
iAUTO Mode
%*
iAUTO Mode, Outside Temperature: 35˚C /24˚C
HIGH FAN SPEED Remote setting temperature: 25˚C with Fan Speed: Auto
Horizontal Airflow direction: Middle, Vertical Airflow direction: Straight
The cooling speed was calculated by measuring the time to reach the setting temperature. At Panasonic Amenity Room (size: 16.6m²)
The effect differs according to conditions in installation and usage.
Remark: iAUTO super high fan speed only applicable for C-model.
Capacity (Btu/h) 9,000 10,000 12,000 13,000 15,000 18,000 24,000 28,000 45,000
INVERTER DELUXE INVERTER DELUXE WIDE FEATURES
Wall-Mounted
PREMIUM INVERTER
SINGLE-SPLIT CS-S10RKH CS-S13RKH CS-S18RKH CS-S24RKH CS-S28RKH
Page 20-21 (CU-S10RKH) (CU-S13RKH) (CU-S18RKH) (CU-S24RKH) (CU-S28RKH)
STANDARD
Window
STANDARD
SINGLE-SPLIT
Page 30-31 CW-C99JH CW-C129VH CW-C189EH CW-C249EH
Floor or Ceiling
SINGLE-SPLIT
Page 32 CS-C12CTH CS-C18CTH CS-C24CTH
(CU-C12CTH) (CU-C18CTH) (CU-C24CTH)