Nothing Special   »   [go: up one dir, main page]

Se P Series Commercial Add On Power Optimizer Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

POWER OPTIMIZER

Power Optimizer
P605 / P650 / P701 / P730 / P800p /
P801 / P850 / P950 / P1100

25
YEAR
WARRANTY

PV power optimization at the module level


The most cost-effective solution for commercial and large field installations

Specifically designed to work with SolarEdge Fast installation with a single bolt
inverters
Advanced maintenance with module level
High efficiency with module-level MPPT, for monitoring
maximized system energy production and
revenue, and fast project ROI Module level voltage shutdown for installer
and firefighter safety
Superior efficiency (99.5%)

Balance of System cost reduction; 50% less Use with two PV modules connected in series
cables, fuses, and combiner boxes, and over 2x or in parallel
longer string lengths possible

solaredge.com
Power Optimizer
P605 / P650 / P701 / P730 / P801
P605 P650 P701 P730 P801
Power Optimizer Module (for 1 x high (for up to (for up to (for up to (for up to
(Typical Module Compatibility) power PV 2 x 60-cell PV 2 x 60/120-cell 2 x 72-cell PV 2 x 72/144 cell
module) modules) PV modules) modules) PV modules)
INPUT
Rated Input DC Power(1) 605 650 700* 730** 800 W
Connection Method Single input for series connected modules
Absolute Maximum Input Voltage
65 96 125 Vdc
(Voc at lowest temperature)
MPPT Operating Range 12.5 – 65 12.5 – 80 12.5 – 105 Vdc
Maximum Short Circuit Current per Input (Isc) 14.1 11 11.75 11** 12.5*** Adc
Maximum Efficiency 99.5 %
Weighted Efficiency 98.6 %
Overvoltage Capacity II
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER
Maximum Output Current 15 Adc
Maximum Output Voltage 80 Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF
Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc
STANDARD COMPLIANCE
EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3
Safety IEC62109-1 (class II safety)
RoHS Yes
Fire Safety VDE-AR-E2100-712:2013-05
INSTALLATION SPECIFICATIONS
Compatible SolarEdge Inverters Three Phase Inverter SE16K & larger
Maximum Allowed System Voltage 1000 Vdc
129 x 153 x 52 /
Dimensions (W x L x H) 129 x 153 x 42.5 / 5.1 x 6 x 1.7 129 x 153 x 49.5 / 5.1 x 6 x 1.9 mm / in
5.1 x 6 x 2
Weight 1064 / 2.3 834 / 1.8 933 / 2.1 gr / lb
Input Connector MC4(2)
Input Wire Length 0.16 / 0.52 0.16 / 0.52, 0.9 / 2.95(3) m / ft
Output Connector MC4
Portrait
Portrait Orientation:
Orientation: - Portrait Orientation: 1.2 / 3.9
Output Wire Length 1.4 / 4.5 m / ft
1.2 / 3.9
- Landscape Orientation: 1.8 / 5.9 Landscape Orientation: 2.2 / 7.2
Operating Temperature Range(6) -40 to +85 / -40 to +185 ºC / ºF
Protection Rating IP68 / NEMA6P
Relative Humidity 0 – 100 %

* For P701 models manufactured after work week 06/2020, the rated DC input is 740W.
** For P730 models manufactured after work week 06/2020, the rated DC input is 760W and the maximum Isc per input is 11.75A.
*** For P801 models manufactured in work week 40/2020 or earlier, the maximum Isc per input in 11.75A.
(1) The rated power of the module at STC will not exceed the Power Optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed.
(2) For other connector types, please contact SolarEdge.
(3) Longer input wire lengths are available for use with split junction box modules. For 0.9m/2.95ft order P730-xxxLxxx.
(4) For ambient temperatures above +70ºC / +158ºF, power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details.

PV System Design Using a SolarEdge 230/400V Grid 230/400V Grid 230/400V Grid 277/480V Grid
Inverter(5)(6)(7)(8) SE16K, SE17 SE25K*, SE33.3K* SE27.6K* SE30K* SE33.3K*, SE40K*
P650, P701, P650, P701, P650, P701, P650, P701,
Compatible Power Optimizers P605 P605 P605 P605
P730, P801 P730, P801 P730, P801 P730, P801
Minimum String Power Optimizers 14 14 14 14 15 15 14 14
Length PV Modules 14 27 14 27 15 29 14 27
Maximum String Power Optimizers 30 30 30 30 30 30 30 30
Length PV Modules 30 60 30 60 30 60 30 60
Maximum Continuous Power per String 11250 11625 12750 12750 W
Maximum Allowed Connected Power per String(8)
(Permitted only when the difference in connected power 13500 13500 15000 15000 W
between strings is 2,000W or less)
Parallel Strings of Different Lengths or Orientations Yes
Maximum Difference in Number of Power Optimizers Allowed
Between the Shortest and Longest String Connected to the 5 Power Optimizers
Same Inverter Unit

* The same rules apply for Synergy units of equivalent power ratings that are part of the modular Synergy Technology Inverter.
(5) P650/P701/P730/P801 can be mixed in one string only with P650/P701/P730/P801. P605 cannot be mixed with any other Power Optimizer in the same string.
(6) For each string, a Power Optimizer may be connected to a single PV module if 1) each Power Optimizer is connected to a single PV module or 2) it is the only Power Optimizer connected to a
single PV module in the string.
(7) For SE16K and above, the minimum STC DC connected power should be 11KW.
(8) To connect more STC power per string, design your project using SolarEdge Designer.
Power Optimizer
P800p / P850 / P950 / P1100
P850 P950 P1100
P800p
Power Optimizer Module (for up to 2 x high (for up to 2 x (for up to 2 x high
(for up to 2 x 96- Unit
(Typical Module Compatibility) power or bi-facial high power or bi- power or bi-facial
cell 5’’ PV modules)
modules) facial modules) modules)
INPUT
Rated Input DC Power(1) 800 850 950 1100 W
Dual input for independently
Connection Method Single input for series connected modules
connected
Absolute Maximum Input Voltage
83 125 Vdc
(Voc at lowest temperature)
MPPT Operating Range 12.5 – 83 12.5 – 105 Vdc
Maximum Short Circuit Current per Input (Isc) 7 14.1* 14.1 Adc
Maximum Efficiency 99.5 %
Weighted Efficiency 98.6 %
Overvoltage Capacity II
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER
Maximum Output Current 18 Adc
Maximum Output Voltage 80 Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF
Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc
STANDARD COMPLIANCE
EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3
Safety IEC62109-1 (class II safety)
RoHS Yes
Fire Safety VDE-AR-E2100-712:2013-05
INSTALLATION SPECIFICATIONS
Three Phase Inverter
Compatible SolarEdge Inverters Three Phase Inverter SE16K & larger
SE25K & larger
Maximum Allowed System Voltage 1000 Vdc
129 x 168 x 59 /
Dimensions (W x L x H) 129 x 162 x 59 / 5.1 x 6.4 x 2.32 mm / in
5.1 x 6.61 x 2.32
Weight 1064 / 2.3 gr / lb
Input Connector MC4(2)
0.16 / 0.52, 0.9 / 2.95, 0.16 / 0.52, 1.3 / 4.26,
Input Wire Length 0.16 / 0.52 0.16 / 0.52, 1.3 / 4.26(3) m / ft
1.3 / 4.26, 1.6 / 5.24(3) 1.6 / 5.24(3)
Output Connector MC4
Portrait Orientation: 1.2 / 3.9
Output Wire Length Landscape Orientation: 2.4 / 7.8 m / ft
Landscape Orientation: 2.2 / 7.2
1.8 / 5.9
Operating Temperature Range(4) -40 to +85 / -40 to +185 ºC / ºF
Protection Rating IP68 / NEMA6P
Relative Humidity 0 – 100 %

* For P850/P950 models manufactured in work week 06/2020 or earlier, the maximum Isc per input is 12.5A. The manufacture code is indicated in the Power Optimizer's serial number.
Example: S/N SJ0620A-xxxxxxxx (work week 06 in 2020)
(1) The rated power of the module at STC will not exceed the Power Optimizer “Rated Input DC Power”. Modules with up to +5% power tolerance are allowed.
(2) For other connector types, please contact SolarEdge.
(3) Longer input wire lengths are available for use with split junction box modules.
For 0.9m/2.95ft order P801/P850-xxxLxxx. For 1.3m/2.95ft order P850/P950/P1100 -xxxXxxx. For 1.6m/5.24ft order P850/P950-xxxYxxx).
(4) For ambient temperatures above +70ºC / +158ºF, power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details.

PV System Design Using a SolarEdge 230/400V Grid 230/400V Grid 230/400V Grid 230/400V Grid 230/400V Grid 277/480V Grid
Inverter(5)(6)(7)(8) SE16K, SE17K SE25K* SE27.6K* SE30K* SE33.3K SE33.3K*, SE40K*
P800p, P850, P950, P800p, P850, P950, P800p, P850, P950, P800p, P850, P950, P800p, P850, P950,
Compatible Power Optimizers P800p, P850, P950
P1100 P1100 P1100 P1100 P1100
Minimum String Power Optimizers 14 14 14 15 14 14
Length PV Modules 27 27 27 29 27 27

Maximum String Power Optimizers 30 30 30 30 30 30


Length PV Modules 60 60 60 60 60 60
Maximum Continuous Power per String 13500 13500 13950 15300 13500 15300 W
2 strings or less – 2 strings or less –
Maximum Allowed Connected Power per String (8) 1 string – 15750 1 string – 15750 1 string – 16200 1 string – 17550
15750 17550
(Permitted only when the difference in connected power W
2 strings or more – 2 strings or more – 2 strings or more – 2 strings or more – 3 strings or more – 3 strings or more –
between strings is 2,000W or less)
18500 18500 18950 20300 18500 20300
Parallel Strings of Different Lengths or Orientations Yes
Maximum Difference in Number of Power Optimizers
Allowed Between the Shortest and Longest String 5 Power Optimizers
Connected to the Same Inverter Unit

* The same rules apply for Synergy units of equivalent power ratings that are part of the modular Synergy Technology Inverter.
(5) P800p/P850/P950/P1100 can be mixed in one string only with P800p/P850/P950/P1100.
(6) For each string, a Power Optimizer may be connected to a single PV module if 1) each Power Optimizer is connected to a single PV module or 2) it is the only Power Optimizer connected to a
single PV module in the string.
(7) For SE16K and above, the minimum STC DC connected power should be 11KW.
(8) To connect more STC power per string, design your project using SolarEdge Designer.
SolarEdge is a global leader in smart energy technology.
By leveraging world-class engineering capabilities and with
a relentless focus on innovation, SolarEdge creates smart
energy solutions that power our lives and drive future
progress.

SolarEdge developed an intelligent inverter solution that


changed the way power is harvested and managed in
photovoltaic (PV) systems. The SolarEdge DC optimized
inverter maximizes power generation while lowering the
cost of energy produced by the PV system.

Continuing to advance smart energy, SolarEdge addresses


a broad range of energy market segments through its PV,
storage, EV charging, UPS, and grid services solutions.

SolarEdge
@SolarEdgePV
@SolarEdgePV
SolarEdgePV
SolarEdge
www.solaredge.com/corporate/contact

solaredge.com
© SolarEdge Technologies, Ltd. All rights reserved.
SOLAREDGE, the SolarEdge logo, OPTIMIZED BY
SOLAREDGE are trademarks or registered trademarks
of SolarEdge Technologies, Inc. All other trademarks
mentioned herein are trademarks of their respective
owners. Date: December 29, 2022 DS-000012-ENG
Subject to change without notice.

Cautionary Note Regarding Market Data and


Industry Forecasts: This brochure may contain
market data and industry forecasts from
certain third-party sources. This information
is based on industry surveys and the
preparer’s expertise in the industry and
there can be no assurance that any such
market data is accurate or that any such
industry forecasts will be achieved.
Although we have not independently
verified the accuracy of such market
data and industry forecasts, we
believe that the market data is
reliable and that the industry
forecasts are reasonable.

solaredge.com