COMPANY JE TICO CONSTRUCTUIN

MODEL R220LC-9S
SERIAL NO HHKHZ614TH000B137
ENGINE S/N 22223168
DELIVERY DATE 4-May-17
EXPIRY DATE 4-May-19
INSPECTION DATE 21-Mar-19 SMR
REPLACEMENT DATE 21-Mar-19 SMR
LOCATION JORDAN GUIMARAS MILEAGE (KM)
CLIENT REQUEST INSPECTION OF CLUSTER WARNING
GMIC TECHNICIAN FINDINGS
1. COMMUNICATION ERROR APPEARED ON CLUSTER
ROOT CAUSE BASE ON ACTUAL FINDINGS OF TECHNICIANS
1. DEFECTIVE MACHINE CONTROL UNIT
ACTION TAKEN BASED ON THE ACCOMPLISHMENT REPORT OF THE TECHNICIAN(S)
1. CHECKED UNIT REPORTED
2. CHECKED REPORTED WARING ON CLUSTER
3. CHECKED MACHINE CONTROL UNIT
4. CHECKED ELECTRICAL SYSTEM OF MACHINE CONTRIOL UNIT
5. PULLED OUT DEFECTIVE MACHINE CONTROL UNIT
6. INSTALLATION OF NEW MACHINE CONTROL UNIT
7. TESTING AND OBSERVATION
8. INTALLATION OF DEFECTIVE MACHINE CONTROL UNIT (MCU) ON DISPLAY UNIT FOR FURTHER OBSERVATION.
NO. QTY PART'S NUMBER PART'S DESCRIPTION
1 1 21Q6-32782 MCU
CLUSTER WARNING APPEARED ON CLUSTER:
INDICATING PROBLEM ON MCU

PULL OUT DEFECTIVE MCU

NEW MCU
INSTALLATION OF NEW MCU

CHECK MONITORING CLUSTER

DONE
SMR 2372.1
SMR 2372.1
MILEAGE (KM) 500 KMS

RVATION.
RT'S DESCRIPTION
MCU
NEW MCU

NEW MCU
DEFECTIVE MCU

INSTALLED NEW MCU

TESTING AND OBSERVATION

DONE
FOR OTHER OBSERVATION ON MACHINE CONTROL UNIT
(MCU). WE INSTALLED THE MACHINE CONTROL UNIT MCU TO
OUR R220LC-9S DISPLAY UNIT.

MACHINE CONTROL
UNIT(MCU) OF DISPLAY UNIT

DEFECTIVE MACHINE CONTROL


UNIT(MCU)
INSTALLATION OF DEFECTIVE MACHINE
CONTROL UNIT(MCU) TO THE DISPLAY UNIT

YELLOW, RED AND GREEN LIGHT APPEARED ON NEW


INSTALLED MACHINE CONTROL UNIT (MCU). INDICATION
OF MACHINE CONTROL UNIT (MCU) ITSELF IS DEFECTIVE.

"COMM ERROR" APPE

DONE
PULLED OUT THE MACHINE CONTROL
UNIT(MCU) OF DISPLAY UNIT
"COMM ERROR" APPEARED AGAIN ON MONITORING
CLUSTER.