Getting Started : With Your TMM5100/470 PINSTAMP Marking System
Getting Started : With Your TMM5100/470 PINSTAMP Marking System
Getting Started : With Your TMM5100/470 PINSTAMP Marking System
Safety Information
The following is provided only as a summary of the safety information you should be aware of before operating your system.
Complete safety information for your marking system is provided in the system Operation Supplement and the system
Installation & Maintenance Manual. Telesis® strongly recommends that you read the complete safety information in those
documents before installing or operating the equipment.
Safety Overview
The system uses high-voltage power supplies and high-pressure pneumatic supplies. Accordingly, there is some danger when
working with, and near, marking machines. The following safety precautions should be observed at all times.
Eye protection may be required when working in close proximity of an operating marker.
Ear protection may be required when working with or near an operating marker.
Keep all body parts, jewelry, and clothing clear of the marker while it is operating.
Do not disconnect electrical components while power is applied to the system.
Do not disconnect the tubing while air pressure is applied to the lines.
Do not remove or defeat the marker’s safety features or protective guards.
Never use the marker in any manner or for any purpose other than that for which it was designed.
2 of 8 33371C
TMM5100/470 Getting Started
Marker Cable
The marker cable connects the marker to the controller. It
supplies the marking head with electrical power and
provides input/output signals from and to the controller for
marker operation.
TMM5100 Marking Head & Marker Cable
Impact Pins and Pin Cartridge
The pin cartridge connects to the marking head. It contains
air-driven impact pins that fire and retract to indent dot
matrix characters into the marking surface.
TMC470 Controller
The controller contains an integrated keyboard with an LCD
display that provides a text-only operator interface. The
back panel provides an electrical interface for connecting to
optional, remote I/O sources. The system software, Air Filter/Regulator & Air Tubing
permanently installed in the controller, provides the user
interface for full operational control of the TMM5100
marking head. The software also provides a library for
storing, loading, and editing user-defined patterns.
33371C 3 of 8
TMM5100/470 Getting Started
The Product Documentation medium contains the Customer Documentation folder, which includes operation, installation,
and maintenance manuals, datasheets, and manual supplements for optional accessories. The documents are Portable
Document Format (PDF) files and can be viewed and printed using Adobe® Reader®.
The Library PDF file is included in the Customer Documentation folder. Use the Library file to access the documentation,
which is organized by marking system.
To open the Library file and access the marking system documentation:
1. Ensure Adobe® Reader® is installed on your computer.
If it is not installed, download and install the free application from the Adobe® website at www.adobe.com.
2. Insert the Product Documentation medium into your machine.
3. Using Windows® Explorer, open the Customer Documentation folder.
4. In the list of files in the Customer Documentation folder, locate and open the LIBRARY.PDF file.
5. When the Library file opens, click the appropriate links to view the documentation associated with your marking system.
You can copy the files to your computer or to your local area network or print the documentation, as necessary.
If you prefer, you can purchase printed documentation by contacting the Telesis Sales Department at (740) 477-5000 or at
sales@telesistech.com. Be sure to specify the document number when ordering.
If you have questions about the Product Documentation medium, contact the Telesis Technical Services Department at (740)
477-5000 or at technical_services@telesistech.com.
4 of 8 33371C
TMM5100/470 Getting Started
The following procedures are listed only for reference to provide a general overview of the installation process.
1. Install the pins and pin cartridge on the marking 9. Connect the return air line (natural) to the
head. Refer to Replacement Procedures in the filter/regulator. Refer to Filter/Regulator Unit
TMM5100 Installation & Maintenance Manual. Installation in the TMM5100 Installation &
2. Mount the marking head on suitable a tool post or Maintenance Manual.
structure. Refer to Marking Head Installation 10. Mount (or place) the controller on a suitable
Requirements in the TMM5100 Installation & surface. Refer to Installation Requirements and
Maintenance Manual. Installation Procedures in the TMC470 Installation &
3. Connect the marker cable to the marking head. Maintenance Manual.
Refer to Marking Head Installation in the TMM5100 11. Connect the marker cable to the controller.
Installation & Maintenance Manual. Refer to Electrical and Data Connections in the
4. Connect the drive air line (black) to the marking TMC470 Installation & Maintenance Manual.
head. Refer to Marking Head Installation in the 12. Connect the power cable to the controller.
TMM5100 Installation & Maintenance Manual. Refer to Electrical and Data Connections in the
5. Connect the return air line (natural) to the marking TMC470 Installation & Maintenance Manual.
head. Refer to Marking Head Installation in the 13. Connect the power cable to the facility power
TMM5100 Installation & Maintenance Manual. outlet. Refer to Electrical and Data Connections in the
6. Mount the filter/regulator to a suitable surface. TMC470 Installation & Maintenance Manual.
Refer to Filter/Regulator Unit Installation in the 14. Set the Drive Air pressure to 80 psi. Refer to Air
TMM5100 Installation & Maintenance Manual. Pressure Adjustments in the TMM5100 Operation
7. Plumb the facility (supply) air to the filter Supplement.
regulator. Refer to Filter/Regulator Unit Installation 15. Set the Return Air pressure to 20 psi. Refer to Air
Requirements and Facility (Supply) Air Installation Pressure Adjustments in the TMM5100 Operation
Requirements in the TMM5100 Installation & Supplement.
Maintenance Manual.
8. Connect the drive air line (black) to the * Set Oil Delivery Rate (metal pin cartridges only).
filter/regulator. Refer to Filter/Regulator Unit Refer to Oil Delivery Rate Adjustment in the
Installation in the TMM5100 Installation & TMM5100 Operation Supplement.
Maintenance Manual.
33371C 5 of 8
TMM5100/470 Getting Started
2. Place the system in Designer mode. F1:FILE F2:EDIT F3:MACHINE F4:MARKER F5:SETUP
The system must be in Designer or Supervisor mode to OPER –Offline– Pattern:UNTITLED
F1:LEVEL F6:< DESIGNER:000
>
create and edit patterns. F2:QUERY TEXT
001:[ ]
Press F5 (SETUP) to display the Setup menu. 002:[ ]
003:[ ]
Press F6 until DESIGNER is displayed on the Setup 004:[ ]
menu. 005:[ ]
Press F1 (LEVEL) to change to the selected mode.
F1:FILE F2:EDIT F3:MACHINE F4:MARKER F5:SETUP
The Password screen is displayed to access Designer OPER –Offline– Pattern:UNTITLED :000
mode.
001:[ Enter Password [ ] ]
Press F1 (ACCEPT). 002:[ ]
Because a password has not yet been defined, this enters 003:[ ]
004:[ F1 ACCEPT F2 CANCEL ]
the default (null) password. The system then displays
005:[ ]
the Designer Main screen.
6 of 8 33371C
TMM5100/470 Getting Started
6. Name and save the pattern. F1:FILE F2:EDIT F3:MACHINE F4:MARKER F5:SETUP
DESN –Offline– Pattern:UNTITLED :000
F1:OPEN
Press F1 (FILE) to display the File menu. F2:NEW F7:<WIZARD >
001:[ ]
Press F4 (SAVE-AS) to display the Pattern Save screen. F3:SAVE
002:[ ]
F4:SAVE-AS
003:[ ]
F5:PROPERTIES
004:[ ]
F6:TEST
005:[ ]
F1 SAVE
8. Pre-position the machine for printing. F1:FILE F2:EDIT F3:MACHINE F4:MARKER F5:SETUP
The Pre-Position command moves the marking pin to DESN –Offline– Pattern:SAMPLE_02
F1:ON/OFF F7:<ONLINE :002
>
where the first pixel will be marked. This helps you F2:PARK
001:[TEXT: 123ABC, 3.000in, 6.000in,
F3:PREPOSITION ]
properly align the marking surface under the pin. 002:[ F4:GO ]
003:[ ]
Press F3 (MACHINE) to display the Machine menu. 004:[
F5:DRYRUN
]
Press F3 (PREPOSITION). 005:[ ]
33371C 7 of 8
TMM5100/470 Getting Started
If you need parts or service for your marking system, be sure to specify the equipment model number and serial number.
Contact Telesis at one of the following locations for more information on any of these services.
Trademarks
Telesis and PINSTAMP are registered trademarks of Telesis Technologies, Inc. in the United States and/or other countries.
Adobe and Reader are registered trademarks of Adobe Systems Incorporated in the United States and/or other countries.
Windows is a registered trademark of Microsoft Corporation in the United States and other countries.
8 of 8 33371C