Flame Detection

S.R.L.
Distribuidores Autorizados
,

FSL100 Series Flame Detectors


UV, UV/IR, IR3
UV, UV/IR, IR3 Flame Detectors
The FSL100 Series of flame detectors from Honeywell delivers robust, fast, and
reliable detection of flaming fires in a wide range of applications.

The range consists of UV, UV/IR and IR3 flame detectors. With a large field of view it can
All utilize sophisticated sensing and signal analysis to detect a range of different types
detect fires quickly while also rejecting false alarms. of fire including hydrocarbon
and non-hydrocarbon sources.
The FSL100 may be small and lightweight for
Available in UV, UV/IR and IR3 we
easy installation but it is designed to work in
have your application covered.
tough indoor/outdoor environments, as well
as potentially explosive atmospheres.

Suitable for Many Applications


• UV, UV/IR and IR3 available
• Hydrocarbon and non-hydrocarbon sources
• Use in potentially explosive atmospheres
• Indoor and outdoor operation
• High visibility red or discrete white models available

Great Performance
• Approved to EN54-10 and FM3260 flame
detector standards
• Comprehensive automatic self test
• Remote manual self test option

Fast & Reliable


• High speed sensors and microprocessor
• Sophisticated analysis algorithms
• False alarm rejection

Reduced Life Cost


• Long life elements
• Pressure compensation to avoid contamination
• 2 year warranty

Ease of Installation and Use


• Relay and mA outputs as standard
• Lightweight GRP housing
• Pre-formed knockouts
• Optional swivel mounting bracket
• Long range test lamp available
Honeywell recommends using a
swivel mount for all installations
and testing installed flame
detectors once per year with an
approved test lamp.
FSL100-UV

• Suitable for indoor applications; for


example fume hoods and hydrogen
storage areas

• Effective solution for materials burning


with low temperatures, e.g. Sulphur

• Alarms to fires from heavy hydrocarbons (wood,


paper, petroleum, etc.), light hydrocarbons
(methanol, methane, etc.), and hydrogen

• Good resistance against the


influences of:
- Direct and reflected sunlight
- Artificial light, such as fluorescent
tubes and glass covered halogen lamps
FSL100-UV/IR

• Analysis of the flame flicker-frequency


for improved false alarm rejection

• Dual sensing methodology enables


a wide range of hydrocarbon and
non-hydrocarbon fires to be
effectively detected

• Good resistance against the influences of:


- Direct and reflected sunlight
- Artificial light, such as fluorescent tubes
and glass covered halogen lamps
- Arcs and electric discharges (static
or from e.g. electric motors)
- The radiation from electric welding
provided that the electric welding takes
place at a distance more than 10 feet from
the flame detector (a welding rod
contains organic compounds which
may produce a small flame)
FSL100-IR3

• Analysis of the flame flicker frequency


for improved false alarm rejection

• Particularly suited to liquid


hydrocarbon and dirty fires

• Affected less by window


contamination or smoky fires

• Good resistance against the


influences of:
- Direct and reflected sunlight
- Artificial light, such as fluorescent
tubes and glass covered halogen
lamps
- Arcs and electric discharges (static
or from e.g. electric motors)
- The radiation from electric welding
provided that the electric welding
takes place at a distance more
than 10 feet from the flame
detector (a welding rod contains
organic compounds which may produce a small flame)

• Especially suitable fires that emit


large amounts of smoke
APPLICATIONS
APPLICATION* UV UV/IR IR3
Aircraft hangars ✓ ✓✓
Atriums ✓ ✓✓
Battery storage rooms / data communication ✓ ✓✓
Biogas ✓ ✓✓
Car, bus, tram and train parking ✓ ✓✓
Clean rooms: semi-conductor, pharmaceutical, & hospital operating rooms ✓ ✓✓
CNG filling/refilling for buses (public transportation) ✓✓ ✓✓
Cold storage ✓✓
Diesel engine rooms ✓ ✓✓
Electric power transformers ✓✓ ✓
Engine test cells/rooms ✓ ✓✓ ✓✓
Fume hoods ✓✓ ✓
Gas cabinets ✓ ✓✓ ✓
Gas/Gasoline engine rooms ✓ ✓✓ ✓✓
Heating rooms for chemicals ✓✓ ✓
Indoor chemical, fuel, and solvent storage ✓ ✓✓ ✓
Indoor hydrocarbon storage and processing ✓ ✓ ✓✓
Indoor hydrogen storage and processing ✓✓ ✓✓
Laboratories ✓ ✓✓ ✓
Loading and unloading terminals: truck, rail, & marine ✓✓ ✓✓
Monitoring of machinery ✓ ✓✓ ✓✓
Oil and Gas pipe line and pumping stations ✓ ✓✓
Outdoor chemical, fuel, paint, and solvent storage ✓ ✓✓
Outdoor hydrogen storage and processing ✓✓
Paint spray booths ✓✓
Radio amplifier rooms / Isolators for antennas ✓✓
Recycling and waste processing plants ✓ ✓✓
Suitable ✓ Recommended ✓✓
*Please contact your regional sales representative to discuss your application
GENERAL SPECIFICATION

SPECIFICATIONS: FSL100 SERIES FLAME DETECTORS


FSL100 Flame Detector types FSL100-UV, FSL100-UVIR and FSL100-IR3; Choice of red or white housings
Range 110 ft /35 m (IR3), 25 m/80 ft (UV, UV/IR) alarming within 10 seconds to a 1 ft2(0.1 m2)n-heptane fire
Cone of vision 90˚minimum horizontal and vertical
Power 10-28 VDC (12-24 VDC nominal)
Continuous green: normal operation
Continuous yellow: fault
Local LEDs
Flashing yellow: Fault and guide to repeat self-test after a self-test failure
Continuous red: alarm
Standard available 4–20 mA (stepped, sinking, non-isolated)
• 0 mA power fault / microprocessor fault
Current output • 2 mA optical fault
• 4 mA normal operation
• >20 mA alarm
Relay output:
De-energized during normal operation, no alarm, SPDT, 30 VDC – 2 A, 60 W max. Energised during normal operation, no fault,
- Alarm relay
SPDT, 30 VDC – 2 A, 60 W max.
- Fault relay
Cable entry M20 clearance. Supplied with gland suitable for cable diameter from 0.2” (5.5mm) to 0.5”(13mm). Terminals
Cable gland & terminals
suitable for 0.5mm2 (20AWG) to 1.5mm2 (15AWG) wire
Start up times <10 sec
Alarm response time 8 to 30 sec
Alarm output settings Selectable LEDs and relays latching/non-latching; factory setting: latching
Automatic & manual Self-Test Automatic Sensor Test (built in Self-Test) and manual Self-Test
Operating current normal 25 mA at 24 VDC
Current in alarm, at 24 VDC ±75 mA at 24 VDC
• Fire control panels using end of line (EOL) and alarm resistors (current increase)
Connections to: • Devices that operate via relay switched outputs
• PLCs with 4–20 mA inputs
To be adjusted to the fire control panel; free terminals are dedicated to the resistors
End of line and alarm resistor Note: the alarm and EOL resistor must be rated 2 W min. each and the total power dissipation of both alarm and EOL resistor
should not exceed 2 W
Housing Glass Reinforced Polyester (GRP), Non-incendive. UV resistant, Self-Extinguishing V–0 (UL-94)
Swivel Mount PA66, UV resistant; Stainless Steel fixings; 280 g (0.62 lb)
Pressure compensating element PCE (Pressure Compensating Element) avoids moisture build-up in the detector housing due to changes in ambient air-pressure
Dimensions 4.9 x 3.15 x 2.25 in (125 x 80 x 57 mm)
Weight 1.05 lb (465 g)
Ingress protection IP65
Temperature, operating –40 ˚F to +158 ˚F (–40 ˚C to +70 ˚C)
Temperature, ambient ATEX and FM class 3611 –13 ˚F to +158 ˚F (–25 ˚C to +70 ˚C)

S.R.L.
Distribuidores Autorizados
,
Honeywell Gas and Flame Detection
Honeywell is able to provide best-in-class gas and flame detection solutions to meet the requirements of all applications and industries.
Contact us in the following ways:

HEADQUARTERS
Europe, Middle East, Africa Americas Asia Pacific
Life Safety Distribution GmbH Honeywell Analytics Distribution Inc. Honeywell Analytics Asia Pacific
Javastrasse 2 405 Barclay Blvd. 7F SangAm IT Tower,
8604 Hegnau Lincolnshire, IL 60069 434, Worldcupbuk-ro, Mapo-gu,
Switzerland USA Seoul 03922,
Tel: +41 (0)44 943 4300 Tel: +1 847 955 8200 Korea
Fax: +41 (0)44 943 4398 Toll free: +1 800 538 0363 Tel: +82 (0) 2 6909 0300
gasdetection@honeywell.com Fax: +1 847 955 8210 Fax: +82 (0) 2 2025 0328
Customer Service: detectgas@honeywell.com India Tel: +91 124 4752700
Tel: 00800 333 222 44 (Freephone number) China Tel: +86 10 5885 8788 3000
Tel: +41 44 943 4380 (Alternative number) analytics.ap@honeywell.com
Fax: 00800 333 222 55 RAE Systems by Honeywell
Middle East Tel: +971 4 450 5800 (Fixed Gas Detection) Phone: 408.952.8200
Middle East Tel: +971 4 450 5852 (Portable Gas Detection) Toll Free: 1.888.723.4800
Fax: 408.952.8480

TECHNICAL SUPPORT
EMEA: HAexpert@honeywell.com
US: ha.us.service@honeywell.com
AP: ha.ap.service@honeywell.com

www.honeywellanalytics.com
www.raesystems.com

Please Note:
While every effort has been made to ensure accuracy in this publication, no
responsibility can be accepted for errors or omissions. Data may change, as well
as legislation, and you are strongly advised to obtain copies of the most recently
issued regulations, standards, and guidelines. This publication is not intended to
form the basis of a contract.

13475_H_FSL100_DS01155_V2_AMER
10/16
© 2016 Honeywell Analytics

You might also like