This document summarizes single core building wires intended for fixed power and lighting installations. The wires have a maximum operating temperature of 70°C and comply with Sri Lankan and British standards. They are made of copper conductors insulated with PVC and have PVC sheathing. The document provides specifications for various wire sizes including nominal cross-sectional area, conductor and insulation diameters and thicknesses, sheath thickness and diameter, resistance, and packing details.
This document summarizes single core building wires intended for fixed power and lighting installations. The wires have a maximum operating temperature of 70°C and comply with Sri Lankan and British standards. They are made of copper conductors insulated with PVC and have PVC sheathing. The document provides specifications for various wire sizes including nominal cross-sectional area, conductor and insulation diameters and thicknesses, sheath thickness and diameter, resistance, and packing details.
This document summarizes single core building wires intended for fixed power and lighting installations. The wires have a maximum operating temperature of 70°C and comply with Sri Lankan and British standards. They are made of copper conductors insulated with PVC and have PVC sheathing. The document provides specifications for various wire sizes including nominal cross-sectional area, conductor and insulation diameters and thicknesses, sheath thickness and diameter, resistance, and packing details.
This document summarizes single core building wires intended for fixed power and lighting installations. The wires have a maximum operating temperature of 70°C and comply with Sri Lankan and British standards. They are made of copper conductors insulated with PVC and have PVC sheathing. The document provides specifications for various wire sizes including nominal cross-sectional area, conductor and insulation diameters and thicknesses, sheath thickness and diameter, resistance, and packing details.
Cables specified in this table are intended for use in Conductor
Application fixed installations for power and lighting.The insulation and other components are suitable to permit operation of the cables at a maximum sustained conductor temperature of 70 °C. Type Cu/PVC/PVC Fire Guard Insualtion Standards BS 6004:2012 , SLS733
Nominal Voltage 300/500V
Insulation 70 °C rated PVC compound Sheath Sheathing PVC compound Packing Supplied in coils of 100 meters or as per customer requirement Conductor Soft annealed copper wires
ITEM N.C NO/NOM INSU. INSU. SHEATH SHEATH Maximum DC Packing
CODE AREA DIA. THICK. O.D. THICK. O.D Resistance Drum Cable mm2 mm mm mm mm mm Ohm/km Type Length
A - 95 1 1/1.13 0.60 2.31 0.8 3.91 18.10 Coil 100m
A- 96 1.5 1/1.38 0.70 2.77 0.8 4.37 12.10 Coil 100m A- 96 sub 1.5 7/0.53 0.70 2.96 0.8 4.56 12.10 Coil 100m A - 97 2.5 1/1.78 0.80 3.37 0.8 4.97 7.41 Coil 100m A - 97 sub 2.5 7/0.67 0.80 3.58 0.8 5.18 7.41 Coil 100m A - 98 4 7/0.85 0.80 4.12 0.9 5.92 4.61 Coil 100m A - 99 6 7/1.04 0.80 4.72 0.9 6.52 3.08 Coil 100m A - 100 10 7/1.35 1.00 6.05 0.9 7.85 1.83 Coil 100m A - 101 16 7/1.70 1.00 7.10 1 9.1 1.15 Coil 100m A - 102 25 19/1.35 1.20 9.15 1.1 11.35 0.727 Coil 100m A - 102 sub 25 7/2.14 1.20 8.82 1.1 11.02 0.727 Coil 100m A - 103 35 19/1.53 1.20 10.05 1.1 12.25 0.524 Coil 100m