PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

BA NO: 214/0319/3115/31/2022 SHEET NO. 1 DATE 20-07-2022

Project Title :PLAN SHOWING THE PROPOSED GI SHEET MACHINE HALL , OPEN
PLOT FORM AND ACS STAFF ROOMS OF M/S. KARANAM INDUSTRIES OF AT PLOT
NO.S-190,191&192 IN S.NO-235,255&257, INDUSTRIAL GROWTH CENTRE,
GUNDLAPALLI, ONGOLE, PRAKASAM DISTRICT.
AREA STATEMENT VERSION NO.: 1.101.111
VERSION DATE: 06/07/2022
PROJECT DETAIL:
Authority: Andhra Pradesh Industrial
Plot Use: Industrial
Infrastructure Corporation
BA No.: 214/0319/3115/31/2022 Plot SubUse: Industrial Building
Application Type: GeneralProposal Land Use Zone: Industrial Use Zone
Project Type: Building Permission Land SubUse Zone: NA
Nature of Development: New Main Abutting Road Width: 0
Location: NA Plot / Shed / House: 190, 191 and 192
SubLocation: New Areas / Approved Layout Survey No.: 235, 255 and 257
Areas
Village: GUNDLAPALLI Block No: 5/97
Mandal: Maddipadu Muncipal Door No.: 4
Street Name: GUNDLAPALLI North: PLOT NO - 215216217
IALA: 3115 South: ROAD WIDTH - 20
Name of the Industrial Undertaking: GC
East: PLOT NO - 193
ONGOLE
Location Name / Name of IE/IDA/EZ/PE*:
West: ROAD WIDTH - 24
GC,Ongole
AREA DETAILS: SQ.MT.
AREA OF PLOT (Minimum) (A) 5685.93
NET AREA OF PLOT (A-Deductions) 5685.93
AccessoryUse Area 9.00
Vacant Plot Area 5142.33
ELEVATION BUA CHECK
Commercial Net BUA 65.60
Industrial Net BUA 469.00
Net BUA Area
ROAD
534.60

I DE Total Net BUA Area 534.60

24.00M W BUILT UP AREA CHECK

1.87(ROAD)
2.08
Proposed BuiltUp Area 534.60

1.38
W2 W/V W/V W/V W/V W/V RS/V
5.79(RO
AD) Substructure Area Added in Buit up Area 9.00

1.34
2.04
Total BuiltUp Area 543.60
W2 WORKSHOP Parking Area Check
61.49 2.07X2.23 Parking Area SQ.MT.
Green Strip
Area : 327.61 Required Parking Area 117.61
D Proposed Parking Area 131.66
53.62
LTP NAME AND SIGNATURE STRUCTURAL ENG NAME AND
51.58 BUILDER NAME AND SIGNATURE
SIGNATURE

W/V

GODOWN
13.54x30.75
3.00

Distribution transformer

14.00
3.00 G.F
Building USE/SUBUSE Details
Building Building Building Building Building Floor Building Type of
Name Use SubUse Type Structure Details Fire Group Roofs
2.30x11.08 PROPOSED 1 Ground + 0
(GODOWN) Industrial Godown NA Non-Highrise Building upper Group A1 5 25 RCC roof
PLOT
floors
PROPOSED 1 Ground + 0
(STAFF Commercial Godowns NA Non-Highrise Building upper Group A1 A.C.C/Tin/Zinc sheet
W/V ROOMS) floors
Waste water recycling
4.87

RS/V
4.38

Visitors Parking
3.43
2.68
BUA Checks before and after transfer of setbacks
Name BuiltUp Area
Perm Prop
PROPOSED-1 (GODOWN) - 469.00
PROPOSED-1 (STAFF ROOMS) - 65.60
4.58

SOLAR HEATING SYSTEM


W/V RS/V W/V W/V W/V RS/V

50.69
3.50
General Conditions

NO217
No.

PLOT
General Conditions
33.50
1 LTP is responsible for any misrepresentation in above aspects.
2 Splay shall be maintained as per GO.MS NO.119. MA & UD dt 27.03.2017 in all the road corners.
GROUND FLOOR PLAN
(Proposed)
14.27

4.00M WIDE INTERNALROAD Internal Road (SCALE 1:100)


RAIN WATER HARVESTING
2.00

Parking Area : 415.34


2.00

PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT


PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT

71.63
58.59

8.41

83.97(ROAD)
PLOTS

82.22(ROAD)
20.00M WIDE ROAD

1.80M GI SHEET ROOF


74.04

72.39

101.42
PLOTS

101.42
PLOTS

7.86 mt. Total Ht.

7.86 mt. from GL

6.96
ISHB COLUMN PLOTS
44.49 6.20M
90.02

PROPOSED (STAFF ROOMS) BRICK WALL PLOTS PROP.SITE


GROUND FLOOR
8.00

Floor Level +0.90 mt.


BLDG HT: 3.90 MT. FLOORING
0.90M PLINTH
Floor
G.LLevel +0.00 mt.
NO OF FLOORS: 1

6.54
1.50M
8.20 0.45 NH-16
2.40
7.46

SECTION-AA
8.00 11.19

Building :PROPOSED (GODOWN)


Floor Name Proposed Net BUA Area
Total Net BUA Area
Total Built Up Area (Sq.mt.) (Sq.mt.) TOPOPLAN
N
(Sq.mt.)
Industrial
Ground Floor 469.00 469.00 469.00
PROPOSED (GODOWN) Total:
Total Number of Same
469.00 469.00 469.00 8000KM RADIUS TOPO PLAN
14.00

1
BLDG HT: 7.86 MT. Buildings:
Total: 469.00 469.00 469.00
6.00M
NO OF FLOORS: 1
UnitBUA Table for Building :PROPOSED (GODOWN)
10.79

Floor Deductions
Green Strip
UnitBUA Gross (Area in
UnitBUA No. of
Area : 251.69 Name UnitBUA Carpet Area No. of Unit
38.82

Type Area Sq.mt.) Rooms


Area
Wall
17.33
GROUND
2.00
33.50 4.11(ROAD) FLOOR
PLAN
G.F GODOWN 447.36 447.36 1.04 446.32 2 1
MACHINERIES
Total: - - 447.36 447.36 1.04 446.32 2.00 1.00
52.69(ROAD) 4.10(ROAD)

1. KNITTING MACHINES 4NO.5X1HP =4.00HP


3.92

2. AIR COMPRESSOR =3.00HP


8.00(ROAD)

7.92(ROAD)

8.00M WIDE INTERNALROAD Internal Road


Area : 453.70

3. STITCHING MACHINES 2NOX1HP =3.00HP


4.00
17.98

56.64(ROAD)

2.00
4. GLOVES PACKING MACHINES =3.00HP
5.98

5.98
7.98

MISC.,,,,,,,,, =12.00HP
54.53
V V
58.49

TOILET TOILET
58.49 3.73X1.77 3.78X1.77 TOTAL POWER =25.00HP
PLOT
NO-193
FRONT ELEVATION D1 D1
58.50M
OFFICE

8.00
ROOM ROOM
3.73X3.77 3.78X3.77 Building :PROPOSED (STAFF ROOMS)
Floor Name Proposed Net BUA Area
Total Net BUA Area
Total Built Up Area (Sq.mt.) (Sq.mt.)
(Sq.mt.)
Commercial
W D W D Ground Floor 65.60 65.60 65.60
3.90 mt. Total Ht.

3.90 mt. from GL

Total: 65.60 65.60 65.60

SITE PLAN
3.12

Total Number of Same


1.77

1.77
BALCONY BALCONY 1
Buildings:
3.96 4.24
Total: 65.60 65.60 65.60
GROUND FLOOR
(Scale - 1:200) PLINTH
Floor Level +0.78 mt.
8.20
UnitBUA Table for Building :PROPOSED (STAFF ROOMS)
Floor
G.L Level +0.00 mt. Floor Deductions
UnitBUA Gross (Area in
UnitBUA No. of
Name UnitBUA Carpet Area No. of Unit
GROUND FLOOR PLAN Type
Area
Area Sq.mt.) Rooms COLOR INDEX
(Proposed) Wall
GROUND Plot / Site lines
(SCALE 1:100) Existing street / road
1.20 FLOOR
PLAN
OFFICE OFFICE 44.66 44.66 3.05 41.61 4 1
Proposed work including servicies
Total: - - 44.66 44.66 3.05 41.61 4.00 1.00 Existing construction proposed to be demolished
SECTION-CC Existing structure to be retained
Work in progress duly sanctioned
Open Space
Drainage and Sewerage work QR CODE
Water Supply work
Deviations
Recreation ground
ISO_A0_(841.00_x_1189.00_MM) PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
This is system generated report and does not require any signature.For further confirmation you can access the department website www.apdpms.ap.gov.in with file number.
Accuracy of Scrutiny Report and Drawing is subject to accuracy of end-user provided data, 3rd party software/hardware/services, etc. We are not liable for any damages which may arise from use, or inability to use the Application.

You might also like